common mistakes

14
Common Mistakes by Carrie Schroeder

Upload: kyros

Post on 21-Jan-2016

43 views

Category:

Documents


0 download

DESCRIPTION

Common Mistakes. by Carrie Schroeder. Emission Factors. Where did they come from? How old are they? If you changed it in your spreadsheet, make sure to change it in Redbud Document where you got the emission factor. Control Efficiencies. - PowerPoint PPT Presentation

TRANSCRIPT

Page 1: Common Mistakes

Common Mistakes

by Carrie Schroeder

Page 2: Common Mistakes

Emission Factors

Where did they come from?

How old are they?

If you changed it in your spreadsheet, make sure to change it in Redbud

Document where you got the emission factor

2

Page 3: Common Mistakes

Control Efficiencies

Is yours included in the emission factor you’re using?

Then don’t forget to check the box!

3

Page 4: Common Mistakes

Controls

Listing controls and efficiencies that do not apply to that pollutantFabric filters and baghouses only control PM

Catalytic converters control CO, VOCs and/or NOx

Catalytic oxidizers control CO and VOCs

4

Page 5: Common Mistakes

Units

Double check that the units in Redbud are still accurate

Check:process rate units

emission factor units

We can’t replicate your emissions if the units are incorrect

5

Page 6: Common Mistakes

Hazardous Air Pollutants (HAPs)

Are they in your VOCs?

Speciate your HAPs out of your VOCs

We especially saw this error on compressor engines

6

Page 7: Common Mistakes

Stack Parameters

If flow rate = 0 then list the unit as a fugitive

Cannot replicate flow rate and gas exit velocity calculation

7

Page 8: Common Mistakes

Stack parametersEquation:

Gas Exit Velocity = flow rate (acfm) ÷

(∏ x r2 x 60)

OR

Flow rate (acfm) = exit gas velocity x

(∏ x r2 x 60)

acfm= actual cubic feet per minute

For non-round stacks

Diameter = 1.128 x √(length x width)8

Page 9: Common Mistakes

Stack Parameters

OR

9

Page 10: Common Mistakes

Reporting/Not Reporting

Emissions reported but have 0 for process rate and/or 0 for annual hours

OR

Process rate reported and/or annual hours reported but emissions are 0 and trace boxes are not checked

10

Page 11: Common Mistakes

Reporting Same Values

If you have the same annual process rate, annual hours, and emissions for 2 years in a row then you will get flagged in our QC program

Usually incorrect, so please don’t just re-enter last years data

Some correct situations might be emergency generators, fire pumps, and process tank heaters

11

Page 12: Common Mistakes

Inconsistent Increase/Decrease in Emissions

You will get flagged if:Annual process rate and hours vary slightly

from previous year to current year, but emissions decrease or increase greatly

And calculation method, controls, emission factor, and emission factor units have not changed

If you legitimately fall into this situation then please make an emission unit note explaining why

12

Page 13: Common Mistakes

Why Your Inventory Is Important

Missing or incorrect release point data lead to errors in geographical location of emissions and impacts photochemical modeling and health risk assessments

Missing or incorrect hours and season fractions lead to errors in temporal distribution of emissions

Errors in SCC and SIC impact control strategy development and attainment plans

Missing or incorrect control equipment data impacts rule development

Good data leads to effective air quality regulation13

Page 14: Common Mistakes

Any Questions?

14