commercial office fit-out working drawings
DESCRIPTION
Here you will find a selection of working drawings designed on ArchiCAD 15.TRANSCRIPT
-
110508
The builder shall check and verify all
Drawing No.:
Checked By:
dimensions and verify all errors and omissions to theArchitect. Do not scale the drawings. Drawings shallnot be used for construction purposes until issuedby the Architect for construction.
Scale: Date:
Status:
Project Name
Client
Plot Date:
Antennae Proposal
Project No:
Drawing Title:
15/01/2013
C:\Users\kay\Documents\Interior Design\Term 3\Commercial Design & Processes\Assessment Tasks\Job Folder\Documentation\CAD Drawings\CAD - A1 - Katie Sargent - 110113.pln
595 Little Collins St Melbourne3000
CATC
as noted
PRELIMINARY
6.8.1
Proposed Floor Plan - First FloorKATIE SARGENT - PROPOSED - PROPOSEDFLOOR PLAN
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
1617181920
DW
RG
12345
1
2
3
4
5
NE
SW
21,600
300
300
11,3
00
11,6
00
1,800 3001200
3,003
300
1,50
090
4,21
090
1,32
090
1,31
090
2,30
030
0
300 5,716 4,408 3,871 3,651
500400
500400
500400
500 3,191 1,500
1,49
91,
087
902,
668
100
1,03
8100
1,25
190
2,91
230
0
9089
91,
010
1,00
030
0
1,20
0
300 4,505 100 1,061 9,552 90 1,200 90
300
8,00
02,
011
989
300
300 21,000 300
S/3
S/1
S/4
S/2
Toilet
Bathroom
Kitchen
Reception
Conference
Executive Director
Creative Director
Viewing Room
Proposed Floor Plan - First Floor1:100
-
110508
The builder shall check and verify all
Drawing No.:
Checked By:
dimensions and verify all errors and omissions to theArchitect. Do not scale the drawings. Drawings shallnot be used for construction purposes until issuedby the Architect for construction.
Scale: Date:
Status:
Project Name
Client
Plot Date:
Antennae Proposal
Project No:
Drawing Title:
15/01/2013
C:\Users\kay\Documents\Interior Design\Term 3\Commercial Design & Processes\Assessment Tasks\Job Folder\Documentation\CAD Drawings\CAD - A1 - Katie Sargent - 110113.pln
595 Little Collins St Melbourne3000
CATC
as noted
PRELIMINARY
6.8.2
Proposed Floor Plan - MezzanineKATIE SARGENT - PROPOSED - PROPOSEDFLOOR PLAN - MEZZANINE
3,400 1,350 3,400 1,350 3,400 1350 3,4003,
400
2400
3,40
0
300 5,743 9,515 2,891 2,851 300
2,686 50 1,78917
270
0 Freelance & Hotdesk Area
Relaxation & Dining
Proposed Floor Plan - Mezzanine1:100
-
110508
The builder shall check and verify all
Drawing No.:
Checked By:
dimensions and verify all errors and omissions to theArchitect. Do not scale the drawings. Drawings shallnot be used for construction purposes until issuedby the Architect for construction.
Scale: Date:
Status:
Project Name
Client
Plot Date:
Antennae Proposal
Project No:
Drawing Title:
15/01/2013
C:\Users\kay\Documents\Interior Design\Term 3\Commercial Design & Processes\Assessment Tasks\Job Folder\Documentation\CAD Drawings\CAD - A1 - Katie Sargent - 110113.pln
595 Little Collins St Melbourne3000
CATC
as noted
PRELIMINARY
6.8.3
Reflected Ceiling Plan - FirstKATIE SARGENT - PROPOSED - RCP - FIRST
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
1617181920
W
123451
2
3
4
5
T
A
T
T
T
T
T T
T
AAA
A A
Legend Halogen Downlight
E27 Pendant
Electrical Cabling
General Power Outlet
Light Switch
Aerial Outelt
Telephone Outlet
AV Projector
Executive Director
Conference Viewing Room Reception
Kitchen
Toilet
Creative Director
Bathroom
Reflected Ceiling Plan - First1:100
-
110508
The builder shall check and verify all
Drawing No.:
Checked By:
dimensions and verify all errors and omissions to theArchitect. Do not scale the drawings. Drawings shallnot be used for construction purposes until issuedby the Architect for construction.
Scale: Date:
Status:
Project Name
Client
Plot Date:
Antennae Proposal
Project No:
Drawing Title:
15/01/2013
C:\Users\kay\Documents\Interior Design\Term 3\Commercial Design & Processes\Assessment Tasks\Job Folder\Documentation\CAD Drawings\CAD - A1 - Katie Sargent - 110113.pln
595 Little Collins St Melbourne3000
CATC
as noted
PRELIMINARY
6.8.4
Reflected Ceiling PLan - MezzanineKATIE SARGENT - PROPOSED - RCP -MEZZANINE
T T
T T
T T
T T
T
A
Freelance & Hotdesk Area
Relaxation & Dining Legend Halogen Downlight
E27 Pendant
Electrical Cabling
General Power Outlet
Light Switch
Aerial Outelt
Telephone Outlet
AV Projector
Reflected Ceiling PLan - Mezzanine1:100
-
110508
The builder shall check and verify all
Drawing No.:
Checked By:
dimensions and verify all errors and omissions to theArchitect. Do not scale the drawings. Drawings shallnot be used for construction purposes until issuedby the Architect for construction.
Scale: Date:
Status:
Project Name
Client
Plot Date:
Antennae Proposal
Project No:
Drawing Title:
15/01/2013
C:\Users\kay\Documents\Interior Design\Term 3\Commercial Design & Processes\Assessment Tasks\Job Folder\Documentation\CAD Drawings\CAD - A1 - Katie Sargent - 110113.pln
595 Little Collins St Melbourne3000
CATC
as noted
PRELIMINARY
6.8.5
Section 1KATIE SARGENT - PROPOSED - Section 1Section 1
200
865
630
790
100
1,81
085
010
03,
052
200
2,29
010
02,
660
100
8,40
0
200
2,39
086
550
4,80
050
01,
763
1,13
7
3,00
010
0
Executive Director
Mezzanine/Freelance Mezzanine Walkway
Executive Director Photocopy/storage
Section 11:100
-
110508
The builder shall check and verify all
Drawing No.:
Checked By:
dimensions and verify all errors and omissions to theArchitect. Do not scale the drawings. Drawings shallnot be used for construction purposes until issuedby the Architect for construction.
Scale: Date:
Status:
Project Name
Client
Plot Date:
Antennae Proposal
Project No:
Drawing Title:
15/01/2013
C:\Users\kay\Documents\Interior Design\Term 3\Commercial Design & Processes\Assessment Tasks\Job Folder\Documentation\CAD Drawings\CAD - A1 - Katie Sargent - 110113.pln
595 Little Collins St Melbourne3000
CATC
as noted
PRELIMINARY
6.8.6
Section 2KATIE SARGENT - PROPOSED - Section 2Section 2
200
2,40
050
010
01,
800
3,38
8
8001
0891
31,
379
100
1,50
040
03,
000
201
1,39
210
72,
648
100
552
3,40
0
200
852
418
1,02
298
2,61
020
03,
000
5,00
03,
388
8,40
0
900
2,29
0
2,29
02,
600
Bathroom
Kitchen Reception Viewing Room Conference
Freelance/Mezzanine
Section 21:100
-
110508
The builder shall check and verify all
Drawing No.:
Checked By:
dimensions and verify all errors and omissions to theArchitect. Do not scale the drawings. Drawings shallnot be used for construction purposes until issuedby the Architect for construction.
Scale: Date:
Status:
Project Name
Client
Plot Date:
Antennae Proposal
Project No:
Drawing Title:
15/01/2013
C:\Users\kay\Documents\Interior Design\Term 3\Commercial Design & Processes\Assessment Tasks\Job Folder\Documentation\CAD Drawings\CAD - A1 - Katie Sargent - 110113.pln
595 Little Collins St Melbourne3000
CATC
as noted
PRELIMINARY
6.8.7
Section 3KATIE SARGENT - PROPOSED - Section 3Section 3
200
2,29
010
02,
650
100
3,07
7
200
8,20
0
860 1,50
02,
700
850
3,16
7
1,24
01,
0201
001,
180
1,48
0
Conference Executive Director
Freelance/Mezzanine
Section 31:50
-
110508
The builder shall check and verify all
Drawing No.:
Checked By:
dimensions and verify all errors and omissions to theArchitect. Do not scale the drawings. Drawings shallnot be used for construction purposes until issuedby the Architect for construction.
Scale: Date:
Status:
Project Name
Client
Plot Date:
Antennae Proposal
Project No:
Drawing Title:
15/01/2013
C:\Users\kay\Documents\Interior Design\Term 3\Commercial Design & Processes\Assessment Tasks\Job Folder\Documentation\CAD Drawings\CAD - A1 - Katie Sargent - 110113.pln
595 Little Collins St Melbourne3000
CATC
as noted
PRELIMINARY
6.8.8
Section 4KATIE SARGENT - PROPOSED - Section 4Section 4
899
1,09
51,
205
9085
8100
552
500
2,91
7
200
8,20
0
8,40
0
1,49
777
7111
916
1,49
53,
417
Viewing Room Mezzanine/Freelance
Photocopy/storageReceptionSection 4
1:50
-
110508
The builder shall check and verify all
Drawing No.:
Checked By:
dimensions and verify all errors and omissions to theArchitect. Do not scale the drawings. Drawings shallnot be used for construction purposes until issuedby the Architect for construction.
Scale: Date:
Status:
Project Name
Client
Plot Date:
Antennae Proposal
Project No:
Drawing Title:
15/01/2013
C:\Users\kay\Documents\Interior Design\Term 3\Commercial Design & Processes\Assessment Tasks\Job Folder\Documentation\CAD Drawings\CAD - A1 - Katie Sargent - 110113.pln
595 Little Collins St Melbourne3000
CATC
as noted
PRELIMINARY
6.8.9
Reception ElevationKATIE SARGENT - PROPOSED - ReceptionElevation
180180
180
180
180
750
5099
865
511,
385
724
3034
130
900
2,30
0
150
Schiavello Green WallH: 29300mm W2850D: 125mm
Reception Elevation1:20
-
110508
The builder shall check and verify all
Drawing No.:
Checked By:
dimensions and verify all errors and omissions to theArchitect. Do not scale the drawings. Drawings shallnot be used for construction purposes until issuedby the Architect for construction.
Scale: Date:
Status:
Project Name
Client
Plot Date:
Antennae Proposal
Project No:
Drawing Title:
15/01/2013
C:\Users\kay\Documents\Interior Design\Term 3\Commercial Design & Processes\Assessment Tasks\Job Folder\Documentation\CAD Drawings\CAD - A1 - Katie Sargent - 110113.pln
595 Little Collins St Melbourne3000
CATC
as noted
PRELIMINARY
6.8.10
Viewing Room ElevationKATIE SARGENT - PROPOSED - Viewing RoomElevation
450
100
350 10
01,
458
2,64
8
2,54
550
55
Viewing Room Elevation1:50
-
110508
The builder shall check and verify all
Drawing No.:
Checked By:
dimensions and verify all errors and omissions to theArchitect. Do not scale the drawings. Drawings shallnot be used for construction purposes until issuedby the Architect for construction.
Scale: Date:
Status:
Project Name
Client
Plot Date:
Antennae Proposal
Project No:
Drawing Title:
15/01/2013
C:\Users\kay\Documents\Interior Design\Term 3\Commercial Design & Processes\Assessment Tasks\Job Folder\Documentation\CAD Drawings\CAD - A1 - Katie Sargent - 110113.pln
595 Little Collins St Melbourne3000
CATC
as noted
PRELIMINARY
6.8.11
Executive Director Elevation, Conference ElevationKATIE SARGENT - PROPOSED - ExecutiveDirector Elevation
1,49
579
4
845
2066
050
780
794
2290
996
8188
158
810
1,44
4
Executive Director Elevation1:50
Conference Elevation1:50
-
110508
The builder shall check and verify all
Drawing No.:
Checked By:
dimensions and verify all errors and omissions to theArchitect. Do not scale the drawings. Drawings shallnot be used for construction purposes until issuedby the Architect for construction.
Scale: Date:
Status:
Project Name
Client
Plot Date:
Antennae Proposal
Project No:
Drawing Title:
15/01/2013
C:\Users\kay\Documents\Interior Design\Term 3\Commercial Design & Processes\Assessment Tasks\Job Folder\Documentation\CAD Drawings\CAD - A1 - Katie Sargent - 110113.pln
595 Little Collins St Melbourne3000
CATC
as noted
PRELIMINARY
6.8.12
Creative Director Elevation, Photocopy & Storage
Area Elevation
KATIE SARGENT - PROPOSED - CreativeDirector Elevation
6655
078
079
0
852
50826
0 2502
50
170
2,29
0
900
5030
730
0 739
2,29
0
2082
0220
7 232
1851
9019
0 215
176
176
176
176
176
Mezzanine stairs
Photocopy machine
Creative Director Elevation1:50
Photocopy & Storage Area Elevation1:50
-
110508
The builder shall check and verify all
Drawing No.:
Checked By:
dimensions and verify all errors and omissions to theArchitect. Do not scale the drawings. Drawings shallnot be used for construction purposes until issuedby the Architect for construction.
Scale: Date:
Status:
Project Name
Client
Plot Date:
Antennae Proposal
Project No:
Drawing Title:
15/01/2013
C:\Users\kay\Documents\Interior Design\Term 3\Commercial Design & Processes\Assessment Tasks\Job Folder\Documentation\CAD Drawings\CAD - A1 - Katie Sargent - 110113.pln
595 Little Collins St Melbourne3000
CATC
as noted
PRELIMINARY
6.8.13
Mezzanine Walkway ElevationKATIE SARGENT - PROPOSED - MezzanineWalkway Elevation
5,92
586
550
1,49
51,
073
50
915
2,41
0
3510
0
2,35
5
Mezzanine Walkway Elevation1:50
-
110508
The builder shall check and verify all
Drawing No.:
Checked By:
dimensions and verify all errors and omissions to theArchitect. Do not scale the drawings. Drawings shallnot be used for construction purposes until issuedby the Architect for construction.
Scale: Date:
Status:
Project Name
Client
Plot Date:
Antennae Proposal
Project No:
Drawing Title:
15/01/2013
C:\Users\kay\Documents\Interior Design\Term 3\Commercial Design & Processes\Assessment Tasks\Job Folder\Documentation\CAD Drawings\CAD - A1 - Katie Sargent - 110113.pln
595 Little Collins St Melbourne3000
CATC
as noted
PRELIMINARY
6.8.14
Freelance/Mezzanine ElevationKATIE SARGENT - PROPOSED -Freelance/Mezzanine Elevation
1,81
282
8
2,41
240
01,
044
414
1,55
9
947
5564
241,
302
2,64
03,
189
Freelance/Mezzanine Elevation1:50
-
110508
The builder shall check and verify all
Drawing No.:
Checked By:
dimensions and verify all errors and omissions to theArchitect. Do not scale the drawings. Drawings shallnot be used for construction purposes until issuedby the Architect for construction.
Scale: Date:
Status:
Project Name
Client
Plot Date:
Antennae Proposal
Project No:
Drawing Title:
15/01/2013
C:\Users\kay\Documents\Interior Design\Term 3\Commercial Design & Processes\Assessment Tasks\Job Folder\Documentation\CAD Drawings\CAD - A1 - Katie Sargent - 110113.pln
595 Little Collins St Melbourne3000
CATC
as noted
PRELIMINARY
6.8.15
Bathroom Elevation, Kitchen ElevationKATIE SARGENT - PROPOSED - Kitchen &Bathroom Elevation
1,12
270
370
5039
110
0
912
400
1,10
050
0
1,99
991
3
3,00
0
5050
700
5096
6
1,99
091
2
209
7741
0041
4
2,30
0
166
9077
4 180
Bathroom Elevation1:50
Kitchen Elevation1:50
6.8 KATIE SARGENT - PROPOSED6.8.1 PROPOSED FLOOR PLAN6.8.2 PROPOSED FLOOR PLAN - MEZZANINE6.8.3 RCP - FIRST6.8.4 RCP - MEZZANINE6.8.5 Section 1 Section 16.8.6 Section 2 Section 26.8.7 Section 3 Section 36.8.8 Section 4 Section 46.8.9 Reception Elevation6.8.10 Viewing Room Elevation6.8.11 Executive Director Elevation6.8.12 Creative Director Elevation6.8.13 Mezzanine Walkway Elevation6.8.14 Freelance/Mezzanine Elevation6.8.15 Kitchen & Bathroom Elevation