SuperTITAN WELD SPECIFICATIONS

SuperTITAN WELD APPLICATIONS

THE SuperTITAN WELD DIFFERENCE• OnlyAll-WeldSelf-Supportavailablethroughdistribution• 3holeboltspatternandflatflanges• Towersshipnestedtominimizesfreightcosts

• Oilandgassites• Railways:minimizesaccesstimerequired• TowerContractors:minimizesassembly • IdealloadingcapacityforSCADA,WISP,Broadbandand2-Way

applications

• All-Weldsectionsminimizeassemblyandinstallationtime• Flatflangesprovidesaneasyconnectionbetweensections(3

boltsperleg)• DesignedtoconformwithCSA-S37-01Standard• Climbinghorizontalsononeface(7/8”or3/4”)• Every5thsectionnestsforreducedfreightcosts• Maximumheight:150ft• Sectionheight:10ft

The flat pads make installation easy

TheSuperTitanWeldisdesignedtomeetmarketloadingrequirementsandconformstoCSA-S37-01Standard.Trylonunderstandstheimportanceofminimizingfreightcostsandasaresultthetowerisdesignedtoshipnested.

Theall-welddesignusesflatpadsallowsforeasyconnections,whichfurtherminimizesassemblyandinstallationtime.Thetowershipswithintegralclimbingfaceandtransmissionlinesupportswhichofferadditionalvalueandeliminatetheneedtopurchaseseparately.P.Eng.stampeddrawingsareavailable.

Integral transmission line supports

Tower ships nested to minimize freight

Page 3: Canadian Version - MBSI WAV

SuperTITAN WELD WIND LOAD CHARTS

1)CSAS37-01Class12)Basedon25mmofRadialIceAccumulation;loadscentrallybalancedattowertop;notxlinesconsidered.

CSA-S37-01StandardClass1HEIGHT MODEL 350 Pa 450 Pa 550 Pa

20’ W700 276 210 16820’ W600 216 166 13220’ W500 214 164 13020’ W400 212 162 12820’ W300 210 160 12620’ W200 194 148 12020’ W100 90 68 5430’ W700 252 192 15230’ W600 198 152 12230’ W500 196 150 12030’ W400 194 148 11830’ W300 192 146 11630’ W200 124 92 7430’ W100 82 62 5040’ W700 238 180 14240’ W600 186 142 11440’ W500 184 140 11240’ W400 182 138 11040’ W300 168 126 9840’ W200 116 86 6840’ W100 76 56 4650’ W700 226 170 13450’ W600 178 136 10850’ W500 176 134 10650’ W400 174 132 10450’ W300 130 94 7250’ W200 110 82 6450’ W100 74 52 4460’ W700 222 164 12860’ W600 170 130 10460’ W500 168 128 10260’ W400 166 126 9860’ W300 124 90 6860’ W200 94 66 5260’ W100 70 52 4070’ W700 220 160 12270’ W600 166 126 100

CSA-S37-01StandardClass1HEIGHT MODEL 350 Pa 450 Pa 550 Pa

70’ W500 164 124 9870’ W400 148 108 8070’ W300 118 86 6670’ W200 90 64 4870’ W100 66 48 3880’ W700 220 158 11880’ W600 160 122 9880’ W500 158 120 9680’ W400 144 102 7680’ W300 114 80 5880’ W200 86 60 4680’ W100 64 46 3690’ W700 224 156 11490’ W600 156 120 9690’ W500 162 120 9490’ W400 138 98 7490’ W300 112 78 5690’ W200 84 58 4690’ W100 62 46 34100’ W600 154 116 94100’ W500 152 114 92100’ W400 134 96 70100’ W300 108 74 52100’ W200 80 56 46100’ W100 60 46 32110’ W500 154 114 90110’ W400 130 92 68110’ W300 104 72 52110’ W200 78 54 44110’ W100 58 44 30120’ W400 128 90 66120’ W300 102 70 52120’ W200 76 52 42120’ W100 56 42 30130’ W300 100 68 50130’ W200 74 52 40130’ W100 54 42 30140’ W200 74 52 40140’ W100 54 40 30150’ W100 52 40 30