www.airport-cables.com [email protected] Caledonian 25 ADDISON Caledonian ULV Cables -PAS (Public Address System) PAS (Public Address System) Loudspeaker Cable FFX200 05mRZ1-R/F 2G1.0 FFX200 05mRZ1-R 2G1.0 (CU/MGT+XLPE/LSZH 2×1.0mmsq 300/500V class 2) FFX200 05mRZ1-F 2G1.0 (CU/MGT+XLPE/LSZH 2×1.0mmsq 300/500V class 5) Plain Annealed Copper LSZH Outer Sheath Mica+XLPE Insulation APPLICATIONS The cables are multicore stranded flexible cables sheathed with thermoplastic LSZH compound. The cables have the ability to restrict the propagation of the flame in the event of a fire. This is especially important to slow down the spreading of the fire as the cables may pass from one area to another within a building. Applications can be found in control and power circuits, power stations, underground tunnels, lifts, escalators, and high-rise buildings. STANDARDS Basic design BS 7629-1 Halogen Free IEC 60754-1 No corrosive gas emission IEC 60754-2 Minimum Smoke Emission IEC 61034-1/2 Reduced Fire Propagation IEC 60332-3C / NF C 32070-2.2 (C1) Flame Retardance IEC 60332-1 / NF C 32-070-2.1 (C2) Fire Resistance IEC 60331 / NF C 32070-2.3(CR1) VOLTAGE RATING 300/500V CABLE CONSTRUCTION Conductor: Plain annealed copper wire, stranded according to IEC(EN) 60228 class 2 or class 5. Insulation: Mica glass tape covered by extruded cross-linked XLPE compound. Outer Sheath: Thermoplastic LSZH compound type LTS3 as per BS 7655-6.1. www.airport-cables.com

Upload: caledonian-tech

Post on 10-Mar-2016

236 views

Category:

Documents


3 download

DESCRIPTION

PAS (Public Address System) Loudspeaker Cables RS485 Data Cables FFX200 05mRZ1-R 2G1.0 (CU/MGT+XLPE/LSZH 2×1.0mmsq 300/500V class 2) FFX200 05mRZ1-F 2G1.0 (CU/MGT+XLPE/LSZH 2×1.0mmsq 300/500V class 5) Public Address System Loudspeaker Cable BS7629-1 speaking Cable The cables are multicore stranded flexible cables sheathed with thermoplastic LSZH compound. The cables have the ability to restrict the propagation of the flame in the event of a fire. This is especially important to slow down the spreading of the fire as the cables may pass from one area to another within a building. Applications can be found in control and power circuits, power stations, underground tunnels, lifts, escalators, and high-rise buildings. Halogen Free IEC 60754-1 No corrosive gas emission IEC 60754-2 Minimum Smoke Emission IEC 61034-1/2 Reduced Fire Propagation IEC 60332-3C/ NF C 32070-2.2 (C1) if you have any inquiries, please feel free to contact us www.airport-cables.com [email protected]

TRANSCRIPT

Page 1: caledonian airport cables public address system

www.airport-cables.com [email protected]

Caledonian

25ADDISON

Caledonian ULV Cables-PAS (Public Address System)

PAS (Public Address System)Loudspeaker Cable FFX200 05mRZ1-R/F 2G1.0FFX200 05mRZ1-R 2G1.0 (CU/MGT+XLPE/LSZH 2×1.0mmsq 300/500V class 2)

FFX200 05mRZ1-F 2G1.0 (CU/MGT+XLPE/LSZH 2×1.0mmsq 300/500V class 5)

Plain Annealed Copper

LSZH Outer Sheath

Mica+XLPE Insulation

APPLICATIONS

The cables are multicore stranded flexible cables sheathed with thermoplastic LSZH compound. The cables have the ability to restrict the propagation of the flame in the event of a fire. This is especially important to slow down the spreading of the fire as the cables may pass from one area to another within a building. Applications can be found in control and power circuits, power stations, underground tunnels, lifts, escalators, and high-rise buildings.

STANDARDS

Basic design BS 7629-1Halogen Free IEC 60754-1No corrosive gas emission IEC 60754-2Minimum Smoke Emission IEC 61034-1/2Reduced Fire Propagation IEC 60332-3C / NF C 32070-2.2 (C1)Flame Retardance IEC 60332-1 / NF C 32-070-2.1 (C2)Fire Resistance IEC 60331 / NF C 32070-2.3(CR1)

VOLTAGe RATING

300/500V

CAbLe CONSTRUCTION

Conductor: Plain annealed copper wire, stranded according to IEC(EN) 60228 class 2 or class 5.Insulation: Mica glass tape covered by extruded cross-linked XLPE compound.Outer Sheath: Thermoplastic LSZH compound type LTS3 as per BS 7655-6.1.

www.airport-cables.com

Page 2: caledonian airport cables public address system

Caledonian26

ADDISON

eLeCTRICAL PROPeRTIeS

Dielectric test: 2000 V r.m.s. x 5’ (core/core)Insulation resistance 1000 MΩ x km (at 20°C)Short circuit temperature 250°C

PhySICAL AND TheRMAL PROPeRTIeS

Temperature range during operation (fixed state): -30°C – +90°C Temperature range during installation (mobile state): -20°C – +50°C Minimum bending radius: 8 × Overall Diameter

CONSTRUCTION PARAMeTeRS

FFX200 05mRZ1-R 2G1.0 FFX200 05mRZ1-F 2G1.0

No.of core

Nominal Cross

Sectional Area

Number & Nominal

Diameter of Strands

NominalInsulation Thickness

NominalSheath

Thickness

Nominal Overall

Diameter

Approx.Weight

mm2 No/mm mm mm mm kg/km

2 1.0 7/0.44 0.5 0.5 5.3 472 1.0 32/0.2 0.5 0.5 5.3 47

NStandard

BS 7629-1

Zero

Halogen FreeIEC60754-1

Low CorrosivityIEC60754-2

EN50267-2-2/3NF C 32-074

Low Smoke EmissionIEC 61034-1&2

EN 50268-1&2/NF C32-073

Reduced Fire PropagationNF C32-070-2.2(C1)

IEC60332-3-24EN50266-2-4

Flame RetardancyNF C32-070-2.1(C2)

IEC60332-1-2/EN50265-2-1

Fire ResistanceIEC 60331

/NF C 32070-2.3(CR1)

www.airport-cables.com

Page 3: caledonian airport cables public address system

www.caledonian-cables.co.uk www.addison-cables.com

Caledonian

27ADDISON

Caledonian ULV Cables-PAS (Public Address System)

Caledonian

27ADDISON

PAS (Public Address System)RS485 Data Cable Re-02y(St)h 1P18ARE-02Y(St)H 1P18A (CU/PE/OSCR/LSZH 1×2×18AWG)

Stranded Tinned Copper

PE Insulation

LSZH Outer Sheath

Overall AL/Polyester Tape With Tinned Copper Drain Wire

Fireproof tape

APPLICATIONS

The cables are designed for RS485 data connections. This cable combines low capacitance insulation with one of the highest levels of screening to provide high speed, interference free, data transmission where continued functionality is required during a fire situation.

STANDARDS

Basic design EIA/TIA 485Halogen Free IEC 60754-1No corrosive gas emission IEC 60754-2Minimum Smoke Emission IEC 61034-1/2Reduced Fire Propagation IEC 60332-3C / NF C 32070-2.2 (C1)Flame Retardance IEC 60332-1 / NF C 32-070-2.1 (C2)Fire Resistance IEC 60331-23 / NF C 32-070-2.3(CR1)

CAbLe CONSTRUCTION Conductors: Tinned annealed copper wire, stranded according to IEC(EN) 60228 class 2 or class 5.Insulation: Solid or foam PE compoundCabling elements: Insulated cores are twisted to form pairs with varying lay length to minimize crosstalk. Overall Screen: Aluminum/ polyester tape with tinned copper drain wire. Fire barrier: Fireproof Tape.Outer Sheath: Thermoplastic LSZH compound type LTS3 as per BS 7655-6.1.

www.airport-cables.com

Page 4: caledonian airport cables public address system

Caledonian28

ADDISON

Caledonian28

eLeCTRICAL PROPeRTIeS

Dielectric test 1000 V r.m.s. for 5’ (core-core)1000 V r.m.s. for 5’ (core-screen)

Impedance 120Ω Capacitance 45 nF/km conductor to conductor

90 nF/km conductor to shield

PhySICAL AND TheRMAL PROPeRTIeS

Temperature range during operation (fixed state): -30°C – +90°C Temperature range during installation (mobile state): -20°C – +50°C Minimum bending radius: 8 × Overall Diameter

CONSTRUCTION PARAMeTeRS

RE-02Y(ST)H 1P18A

No.of pair

WireGange

Number & Nominal

Diameter of Strands

NominalInsulation Thickness

NominalSheath

Thickness

Nominal Overall

Diameter

Approx.Weight

AWG No/mm mm mm mm kg/km 1 18 7/0.404 1.15 1.2 10.5 1001 18 16/0.254 1.15 1.2 10.5 100

NStandard

EIA/TIA 485

Zero

Halogen FreeIEC60754-1

Low CorrosivityIEC60754-2

EN50267-2-2/3NF C 32-074

Low Smoke EmissionIEC 61034-1&2

EN 50268-1&2/NF C32-073

Reduced Fire PropagationNF C32-070-2.2(C1)

IEC60332-3-24EN50266-2-4

Flame RetardancyNF C32-070-2.1(C2)

IEC60332-1-2/EN50265-2-1

Fire ResistanceIEC 60331

/NF C 32070-2.3(CR1)

www.airport-cables.com