cable tray system - startseite - niedax€¦ · cable ladder fittings cable ladder system cable...
TRANSCRIPT
Covers
Accessoires
Cable Ladder
Fittings
CABLE LADDER SYSTEM
CABLE TRAY SYSTEM
240
Cable ladders are ideal to install large volumes of heavy duty power cables. The long rung spacing
means full free air rating of cables. Higher current fl ow can be achieved at the same cable cross-
section. Overheating and consecutive damaging of cables is avoided. The new shape of the side
rail allows higher cable loads at similar support spans, the continuous perforation in the siderails
guarantees easy mounting of fi ttings. Cables can be installed and fi xed to the rungs using appro-
priate yoke clamps. Niedax Cable ladders can be slit together to minimize transport and storage
volume needs.
241241
SYSTEM Cable Ladder KL... Page 246
Splice Plate KSV... Page 246
Adjustable Splice Plate KGV... Page 246
Adjustable Splice Plate KWV... Page 247
Barrier Strip RW 85... Page 247
Splice Plate for Barrier Strip RTV 85 E2 Page 247
Mounting Clamp for Barrier Strip KLWC 11... Page 247
Horizontal Elbow 90°, small radius KLBK... Page 248
Horizontal Elbow 90°, large radius KLBG... Page 248
Extension Horizontal Tee KLTA... Page 249
Horizontal Tee KLT... Page 249
Horizontal Cross KLK... Page 249
Adjustable Vertical Elbow KGS... Page 250
Cable Ladder Connection Bracket KLAS 100 Page 250
Pair of Protective End Caps SKK 100 Page 250
Ladder Drop Out KLAB... Page 250
Cable Ladder Mounting Bracket KLTB 6... Page 251
Two Hole Corner Angle WWU... Page 251
Three Hole Corner Angle WWA... Page 251
Cover for Cable Tray/Ladder RDV... Page 252
Cover for 90° Horizontal Elbow, small radius KLBKDV... Page 252
Cover for Horizontal Tee KLTDV... Page 252
Turnbolt Lock RDRS... Page 253
ZUBEHÖR
Available Side Rail Heights
242
CABLE LADDER SYSTEM
243
Cable Ladder Specifications:
A. CABLE TRAY DESIGN1. Cable Tray shall be made of straight sections, fittings and accessories as defined in the latest NEMA standards per
NEMA VE-1. Standard cable trays shall be UL classified as equipment grounding conductors.
B. MATEriAL1. Pre-galvanized steel. The structural quality of the steel shall meet the minimum yield and tensile strength of the
ASTM standards (ASTM A 653) with G 90 coating thickness. All cable trays to be labeled for material identification purposes.
2. Hot dipped galvanized steel. All trays to be hot-dipped galvanized in accordance with ASTM A123. All trays to be labeled for material identification.
3. Stainless steel. All trays are to be constructed of AiSA type 304 or 316 stainless steel. All trays to be labeled for material identification.
C. TRAY TYPES 1. Ladder cable tray. Ladder shall consist of two side-rails with rungs riveted to the bottom flange of the side-rails.
rungs shall be spaced 8” or 12” (200 or 300 mm) on center. rungs shall not protrude below the bottom of the side-rail.
D. TRAY SIZE 1. Height: Ladder shall have an overall height of 4” (100 mm).
Minimum load depth shall be 3.5” (90 mm).
2. Width: Widths shall be 8”, 12”, 16”, 20” and 24” (200, 300, 400, 500 and 600 mm)
3. Length: Length shall be a nominal 10’ or 3 meters and 20’ or 6 meters
E. ACCESSORIES1. Covers. Covers shall be supplied to protect tray cable where needed. Covers will be solid and contain three pair of
turn-bolt locks to secure the covers to the lips of the cable tray, requiring only the use of a slotted screwdriver.
2. Splice plates. Splice plates shall fasten to the outside of the cable tray side-rails and wrap around and snap onto each section of tray. Bolts and nuts are used to fasten to the tray and are included with splice plates. Plates shall not exceed the NEMA VE-1 resistance of 330 micro ohms.
3. Other accessories shall be furnished as required to protect, support, and install a cable tray system. Fittings shall made of the same material as the cable tray whenever possible. Fittings can be of factory construction or also be of a type that allows field constructed fittings.
F. LOADING CAPABILITIES1. Cable tray shall meet the load/span class designation in accordance with NEMA VE 1 and CSA E22.2 No 126.1.
Cable tray shall also meet load/span designation in accordance with iEC 61537
G. DESiGN AND MANUFACTUrE1. Cable tray design shall be manufactured by The Niedax Group.
244
CABLE LADDER SYSTEM
Load/Span Class Designation in accordance with NEMA VE 1 and CSA E22.2 No. 126.1
Niedax SeriesMinimum Area
Load class in accordance toNEMA VE 1
(calculational)mm2 / in.2
in accordanceto NEMA VE 2
mm2 / in.2
Rated LoadKg/m / lb./ft.
Supportspacingm / ft.
Load/SpanClass
KLX 100.203 414.0 / 0.64 258 / 0.4 107 / 72 2 / 6.6 8A, A
KLX 100.303 414.0 / 0.64 258 / 0.4 107 / 72 2 / 6.6 8A, A
KLX 100.403 414.0 / 0.64 258 / 0.4 107 / 72 2 / 6.6 8A, A
KLX 100.503 414.0 / 0.64 258 / 0.4 107 / 72 2 / 6.6 8A, A
KLX 100.603 414.0 / 0.64 258 / 0.4 107 / 72 2 / 6.6 8A, A
KLX 100.203 F 414.0 / 0.64 258 / 0.4 107 / 72 2 / 6.6 8A, A
KLX 100.303 F 414.0 / 0.64 258 / 0.4 107 / 72 2 / 6.6 8A, A
KLX 100.403 F 414.0 / 0.64 258 / 0.4 107 / 72 2 / 6.6 8A, A
KLX 100.503 F 414.0 / 0.64 258 / 0.4 107 / 72 2 / 6.6 8A, A
KLX 100.603 F 414.0 / 0.64 258 / 0.4 107 / 72 2 / 6.6 8A, A
245
246
CABLE LADDER SYSTEM
Cable LadderC-channel rungs with 11 mm slot width, standard spacing 300 mm
Support Span (m)
Uni
form
ly d
istr
ibut
ed lo
ad q
Specified load ratings are independant of splice plate location.
KSV 100... splice plates have to be ordered separately.Cable ladder is available in 3 meter length as well.
Load Chart: q = uniformly distributed load (tested according to DIN EN IEC 61537 standard)
KL 100.203
100 | 3,9 200 | 7,9 1,5 6000 | 236,2KL 100.303 100 | 3,9 300 | 11,8 1,5 6000 | 236,2KL 100.403 100 | 3,9 400 | 15,7 1,5 6000 | 236,2KL 100.503 100 | 3,9 500 | 19,7 1,5 6000 | 236,2KL 100.603 100 | 3,9 600 | 23,6 1,5 6000 | 236,2KL 100.203 F
100 | 3,9 200 | 7,9 1,5 6000 | 236,2KL 100.303 F 100 | 3,9 300 | 11,8 1,5 6000 | 236,2KL 100.403 F 100 | 3,9 400 | 15,7 1,5 6000 | 236,2KL 100.503 F 100 | 3,9 500 | 19,7 1,5 6000 | 236,2KL 100.603 F 100 | 3,9 600 | 23,6 1,5 6000 | 236,2
S
SSSSF
FFFF
model no. heightH
widthB
thick- ness
t
lengthA
mm | Inch mm | Inch mm mm | Inch
Pack/ Box Qty
6 m6 m6 m6 m6 m6 m6 m6 m6 m6 m
Weightper 100
m
kg
350,70370,50390,20409,90429,60386,98371,50391,30411,00473,79
61
Splice Plate
2 pieces required per joint
form-locking straight splice plate for cable ladders
KSV 100 S
100 | 3,9KSV 100 F
100 | 3,9S
F
model no. heightH
mm | Inch
Pack/ Box Qty
1010
Weightper 100
pcs
kg
26,3724,83
UL classified splice plates ensure electrical continuity and proper bonding.
Adjustable Splice Platevertical
2 pieces required per joint
use for custom built horizontal elbows
KGV 100 S
100 | 3,9KGV 100 F
100 | 3,9S
F
model no. heightH
mm | Inch
Pack/ Box Qty
1010
Weightper 100
pcs
kg
53,2558,20
UL classified splice plates ensure electrical continuity and proper bonding.
247
Adjustable Splice Platehorizontal
2 pieces required per joint
KWV 100 S
100 | 3,9KWV 100 F
100 | 3,9S
F
model no. heightH
mm | Inch
Pack/ Box Qty
1010
Weightper 100
pcs
kg
55,059,6
UL classified splice plates ensure electrical continuity and proper bonding.
Barrier Strip
to separate wires and cables of different voltage levels or with different functions
RW 85
80 | 3,1 0,9RW 85 F
80 | 3,1 0,9S
F
model no. heightH
thick- ness
tmm | Inch mm
Pack/ Box Qty
10 x 3 m10 x 3 m
Weightper 100
m
kg
78,3986,12
61
Splice Plate for Barrier Strip
for positive locking connections and proper bonding of barrier strips
RTV 85 E2
79,5 | 3,1 80 | 3,1E2
model no. heightH
lengthA
mm | Inch mm | Inch
Pack/ Box Qty
20
Weightper 100
pcs
kg
2,03
61
Mounting Clamp for Barrier Strip
to fix barrier strips to KL… cable ladders (slot width 11 mm)
Suitable for: RW… barrier strip
KLWC 11
KLWC 11 F
S
F
model no. Pack/ Box Qty
5050
Weightper 100
pcs
kg
23
61
248
CABLE LADDER SYSTEM
Horizontal Elbow 90° (small radius)with perforated siderails
KSV 100... splice plates have to be ordered separately.
KLBK 100.203
100 | 3,9 200 | 7,9KLBK 100.303 100 | 3,9 300 | 11,8KLBK 100.403 100 | 3,9 400 | 15,7KLBK 100.503 100 | 3,9 500 | 19,7KLBK 100.603 100 | 3,9 600 | 23,6KLBK 100.203 F
100 | 3,9 200 | 7,9KLBK 100.303 F 100 | 3,9 300 | 11,8KLBK 100.403 F 100 | 3,9 400 | 15,7KLBK 100.503 F 100 | 3,9 500 | 19,7KLBK 100.603 F 100 | 3,9 600 | 23,6
S
SSSSF
FFFF
model no. heightH
widthB
mm | Inch mm | Inch
Pack/ Box Qty
1111111111
Weightper 100
pcs
kg
466,77533,05599,35665,67731,99513,45586,36659,29732,24805,19
Please use a KLBK... and a KLBG... elbow to form a 90° bend for 2 runs of ladder tray of the samewidth being installed in parallel.
Horizontal Elbow 90° (large radius)with perforated siderails
KSV 100... splice plates have to be ordered separately.
KLBG 100.203
100 | 3,9 200 | 7,9KLBG 100.303 100 | 3,9 300 | 11,8KLBG 100.403 100 | 3,9 400 | 15,7KLBG 100.503 100 | 3,9 500 | 19,7KLBG 100.603 100 | 3,9 600 | 23,6KLBG 100.203 F
100 | 3,9 200 | 7,9KLBG 100.303 F 100 | 3,9 300 | 11,8KLBG 100.403 F 100 | 3,9 400 | 15,7KLBG 100.503 F 100 | 3,9 500 | 19,7KLBG 100.603 F 100 | 3,9 600 | 23,6
S
SSSSF
FFFF
model no. heightH
widthB
mm | Inch mm | Inch
Pack/ Box Qty
1111111111
Weightper 100
pcs
kg
615,91731,86847,88964,05
1.080,14677,49805,02932,65
1.060,441.188,13
Please use a KLBK... and a KLBG... elbow to form a 90° bend for 2 runs of ladder tray of the samewidth being installed in parallel.
249
Extension Horizontal Teewith perforated siderails
KSV 100... splice plates have to be ordered separately.
KLTA 100.203
100 | 3,9 200 | 7,9KLTA 100.303 100 | 3,9 300 | 11,8KLTA 100.403 100 | 3,9 400 | 15,7KLTA 100.503 100 | 3,9 500 | 19,7KLTA 100.603 100 | 3,9 600 | 23,6KLTA 100.203 F
100 | 3,9 200 | 7,9KLTA 100.303 F 100 | 3,9 300 | 11,8KLTA 100.403 F 100 | 3,9 400 | 15,7KLTA 100.503 F 100 | 3,9 500 | 19,7KLTA 100.603 F 100 | 3,9 600 | 23,6
S
SSSSF
FFFF
model no. heightH
widthB
mm | Inch mm | Inch
Pack/ Box Qty
1111111111
Weightper 100
pcs
kg
550,75576,52601,20625,77650,34605,83634,17661,32688,35715,37
Horizontal Teewith perforated siderails
KSV 100... splice plates have to ordered separately.
KLT 100.203
100 | 3,9 200 | 7,9KLT 100.303 100 | 3,9 300 | 11,8KLT 100.403 100 | 3,9 400 | 15,7KLT 100.503 100 | 3,9 500 | 19,7KLT 100.603 100 | 3,9 600 | 23,6KLT 100.203 F
100 | 3,9 200 | 7,9KLT 100.303 F 100 | 3,9 300 | 11,8KLT 100.403 F 100 | 3,9 400 | 15,7KLT 100.503 F 100 | 3,9 500 | 19,7KLT 100.603 F 100 | 3,9 600 | 23,6
S
SSSSF
FFFF
model no. heightH
widthB
mm | Inch mm | Inch
Pack/ Box Qty
1111111111
Weightper 100
pcs
kg
868,22951,82
1.034,331.116,731.244,27
955,041.047,001.137,761.228,401.368,70
Horizontal Crosswith perforated siderails
KSV 100... splice plates have to be ordered separately.
KLK 100.203
100 | 3,9 200 | 7,9KLK 100.303 100 | 3,9 300 | 11,8KLK 100.403 100 | 3,9 400 | 15,7KLK 100.503 100 | 3,9 500 | 19,7KLK 100.603 100 | 3,9 600 | 23,6KLK 100.203 F
100 | 3,9 200 | 7,9KLK 100.303 F 100 | 3,9 300 | 11,8KLK 100.403 F 100 | 3,9 400 | 15,7KLK 100.503 F 100 | 3,9 500 | 19,7KLK 100.603 F 100 | 3,9 600 | 23,6
S
SSSSF
FFFF
model no. heightH
widthB
mm | Inch mm | Inch
Pack/ Box Qty
1111111111
Weightper 100
pcs
kg
1.183,261.276,811.368,171.459,331.595,621.301,591.404,491.504,991.605,261.755,18
250
CABLE LADDER SYSTEM
Adjustable Vertical Elbowvertical
delivered as a kit (not assembled)
KGS 100.203
100 | 3,9 200 | 7,9KGS 100.303 100 | 3,9 300 | 11,8KGS 100.403 100 | 3,9 400 | 15,7KGS 100.503 100 | 3,9 500 | 19,7KGS 100.603 100 | 3,9 600 | 23,6KGS 100.203 F
100 | 3,9 200 | 7,9KGS 100.303 F 100 | 3,9 300 | 11,8KGS 100.403 F 100 | 3,9 400 | 15,7KGS 100.503 F 100 | 3,9 500 | 19,7KGS 100.603 F 100 | 3,9 600 | 23,6
S
SSSSF
FFFF
model no. heightH
widthB
mm | Inch mm | Inch
Pack/ Box Qty
1111111111
Weightper 100
pcs
kg
660,83684,50708,18731,85755,53726,08752,13778,14804,18830,23
Cable Ladder Connection Bracket
cable ladder connector bracket for field made horizontal tees
KLAS 100
100 | 3,9F
model no. heightH
mm | Inch
Pack/ Box Qty
20
Weightper 100
pcs
kg
20,5
Pair of Protective End Caps
protective end cap for KL 100… siderails
Suitable for: Cable Ladder
SKK 100
100 | 3,9 yellowK10
model no. heightH
color
mm | Inch
Pack/ Box Qty
10 sets
Weightper 100
pair
kg
5
Ladder Drop Outwith rounded edges
Suitable for: KL… cable ladders
KLAB 200
190 | 7,5KLAB 300 290 | 11,4KLAB 400 390 | 15,4KLAB 500 490 | 19,3KLAB 600 590 | 23,2KLAB 200 F
190 | 7,5KLAB 300 F 290 | 11,4KLAB 400 F 390 | 15,4KLAB 500 F 490 | 19,3KLAB 600 F 590 | 23,2KLAB 200 E3
190 | 7,5KLAB 300 E3 290 | 11,4KLAB 400 E3 390 | 15,4KLAB 500 E3 490 | 19,3KLAB 600 E3 590 | 23,2
S
SSSSF
FFFF
E3
E3E3E3E3
model no. widthB
mm | Inch
Pack/ Box Qty
111111111111111
Weightper 100
pcs
kg
40,8563,6086,35
143,37173,4245,9670,9896,01
158,73191,7841,0363,9386,83
144,21174,45
251
Cable Ladder Mounting Bracket
2 pieces required per bracket
hold down clamp to fix cable ladders on brackets
KLTB 6
KLTB 6 F
KLTB 6 E3
KLTB 6 E5
S
F
E3
E5
model no. Pack/ Box Qty
50505050
Weightper 100
pcs
kg
2,132,222,372,40
Two Hole Corner Angle
for floor-, ceiling- or wall-mount
WWU 150/8
5WWU 150/8 E3
4WWU 150/8 E5
4
F
E3
E5
model no. thick- ness
tmm
Pack/ Box Qty
505050
Weightper 100
pcs
kg
19,1114,8714,62
Three Hole Corner Angle
for floor-, ceiling- or wall-mount
WWA 100
5WWA 100 E3
4F
E3
model no. thick- ness
tmm
Pack/ Box Qty
5050
Weightper 100
pcs
kg
24,9819,75
252
CABLE LADDER SYSTEM ACCESSOIRES
Cover for Cable Tray/Ladderwith turnbolt locks
RDV 200
200 | 7,9RDV 300 300 | 11,8RDV 400 400 | 15,7RDV 500 500 | 19,7RDV 600 600 | 23,6RDV 200 F
200 | 7,9RDV 300 F 300 | 11,8RDV 400 F 400 | 15,7RDV 500 F 500 | 19,7RDV 600 F 600 | 23,6
S
SSSSF
FFFF
model no. inside dimension
(B)mm | Inch
Pack/ Box Qty
2 x 3 m2 x 3 m2 x 3 m2 x 3 m2 x 3 m2 x 3 m2 x 3 m2 x 3 m2 x 3 m2 x 3 m
Weightper 100
m
kg
133,2230,2334,1412,6491,1146,6253,2367,5453,8540,2
For outdoor service covers need to be secured against windloads using heavy duty cover clamps orsteel cable ties.
Cover for 90° Horizontal Elbow (small radius)with turnbolt locks
KLBKDV 200
203 | 8KLBKDV 300 303 | 11,9KLBKDV 400 403 | 15,9KLBKDV 500 503 | 19,8KLBKDV 600 603 | 23,7KLBKDV 200 F
203 | 8KLBKDV 300 F 303 | 11,9KLBKDV 400 F 403 | 15,9KLBKDV 500 F 503 | 19,8KLBKDV 600 F 603 | 23,7
S
SSSSF
FFFF
model no. inside dimension
(B)mm | Inch
Pack/ Box Qty
1111111111
Weightper 100
pcs
kg
202,76317,53444,62584,04735,79223,04349,28489,08642,44809,37
For outdoor service covers need to be secured against windloads using heavy duty cover clamps orsteel cable ties.
Cover for Horizontal Teewith turnbolt locks
KLTDV 200
203 | 8KLTDV 300 303 | 11,9KLTDV 400 403 | 15,9KLTDV 500 503 | 19,8KLTDV 600 603 | 23,7KLTDV 200 F
203 | 8KLTDV 300 F 303 | 11,9KLTDV 400 F 403 | 15,9KLTDV 500 F 503 | 19,8KLTDV 600 F 603 | 23,7
S
SSSSF
FFFF
model no. inside dimension
(B)mm | Inch
Pack/ Box Qty
1111111111
Weightper 100
pcs
kg
444,10636,22844,03
1.067,551.306,77
488,51699,84928,44
1.174,311.437,45
For outdoor service covers need to be secured against windloads using heavy duty cover clamps orsteel cable ties.
253
Turnbolt Locklocking nut included
for field modifications of covers
Suitable for: RD... and RDV... coversfitting covers
RDRS 9
RDRS 9 F
S
F
model no. Pack/ Box Qty
100100
Weightper 100
pcs
kg
1,21,6
Not sufficient for securing covers to tray installed vertically or sideways nor for securing coversagainst windloads. Please use self tapping screws, steel cable ties or cover-hinges in addition.