busway power distribution - kirby · pdf filebusway power distribution bd® plug-in ... top...
TRANSCRIPT
Busway Power Distribution
BD® Plug-In (225 —1600 Ampere)225-1600 Amperes / 600 Volts or Less
SELECTION
AmpereRating
Plug In®10'- 0"StraightLengthCatalogNumber
CaseDimensions(inches)
ShippingWeightLb./Ft.
®ListPrice $
GroundBusAdderSuffix GK
ListPrice $
90° Elbow Prefix
®<sCatalogNumber
ListPrice $
Switch-BoardConnec-tion®Prefix
ListPrice $
Building ExpansionFitting
CatalogNumber
ListPrice $
Aluminum3 Phase, 3 Wire 600V or Less
225400
600800
10001200
ABD302ABD304
ABD306ABD308
ABD310ABD312
4X* x m4%x8X.
6'Xe X 8'Aex. x $7A12!4x8%12!«x 8%
910
13142228
1010.1240.1540.2160.2440.3290.
37.37.
38.46.
46.46.
ALD302ALD304
ALD306ALD308
ALD310ALD312
1110.1180.1270.1450.
1780.2030.
FEA302FEA304
FEA306FEA308
FEA310FEA312
760.800.
1070.1240.
1410.1730.
EPA302EPA304
EPA306EPA308
EPA310EPA312
2360.2770.
3150.4320.
4790.5670.
3 Phase, 4 Wire — Full Capacity Neutral 277/480V225400
600
800
10001200
ABD4024ABD4044
ABD4064
ABD4084
ABD4104ABD4124
4'/6 x 8%4M« X 8X
6'A x 854
8% x 8%
rax8',412^x854
10!<
12
1538
27
3138
1250.1570.
2170.
2520.
3160.4010.
37.37.
38.
46.
46.46.
ALD4024ALD4044
ALD4064
ALD4084
ALD4104ALD4124
1350.1440.
1620.
1730.
2290.2540.
FEA4024FEA4044
FEA4064
FEA4084
FEA4104FEA4124
840.
920.
1220.
1390.
1680.1910.
EPA4024EPA4044
EPA4064
EPA4084
EPA4104EPA4124
2850.3330.
4170.
4910.
5580.7250.
Copper3 Phase, 3 Wire 600V or Less225
400600800
100013501600
BDP302
BDP304BDP306
BDP308
BDP310
BDP313BDP316
4Y,t x S'/i
4K« x 8%4X» x 8%6X. x m6'A, x 8%
12% x 8%12Mx8'/G
9
125513K1814
222829
1250.1890.2420.
3540.
3830.
5790.6170.
56.
56.58.58.58.83.118.
LDP301
LDP304LDP306
LDP308
LDP310
LDP313LDP316
1200.1390.1550.
1890.2040.
2820.2930.
FEP302
FEP304FEP306
FEP308
FEP310
FEP313FEP316
830.
960.1290.1560.
1760.2320.2370.
EJP302
EJP304EJP306
EJP308
EJP310
EJP313EJP316
2630.
3450.4080.
5760.
6230.
8160.8950.
3 Phase, 4 Wire — Full Capacity Neutral 277/480V225
400600
800
1000
BDP4024
BDP4044BDP4064
BDP4084
BDP4104
4M« x 87/i
4K. X 8%4M« x 8«
8!4x8%
8I4 x 8%
12
MS15!*
28
32
1620.
2730.3100.
4520.
5290.
56.
56.58.
58.
58.
LDP4024
LDP4044LDP4064
LDP4084
LDP4104
1480.
1810.1920.
2500.
2730.
FEP4024
FEP4044FEP4064
FEP4084
FEP4104
940.
1170.1450.
1810.
1910.
EJP4024
EJP4044EJP4064
EJP4084
EJP4104
3220.
4480.5090.
6860.
8000.
"M" Rating / Standard RatingConversion Table1000/A Square Inch"M" Rating
22540060080010001200135016002000250030004000
Standard 55°BDP
—6008008001000—13501600
————
C Rating
Right EdgewiseElbow (-2)
Left EdgewiseElbow (-4)
For inches / millimeters conversion, see page 583.
©Consult local sales office for five foot length.©List prices are for standard construction, for higher
short circuit ratings add an "H" after the "D" or "P"{ABDH302 or BDPH302) and add 20% to the list price.Consult sales office for ratings.
®"GK" is an internal ground bus. For any other groundconfiguration, consult local sales office. List price isper foot. Please use following footage for fittings:
Elbow - 3 footSWB - 1'End Cable Tap Box - 1'Center Cable Tap Box - 10'Building Expansion - 10'
Suffix
-1
-2
-3
-4
Description
Right Flatwise
Right Edgewise
Left Flatwise
Left Edgewise
Appropriate suffix must be
added to Elbow Catalog
Number to order.
©Switchboard stub includes flange to cover cutout intop of indoor switchboard and 6" of bus insideswitchboard. Connecting hardware supplied byswitchboard manufacturer.
= Warehouse Stock
Siemens Electrical Products SPEEDFAX 2000 Discount Schedule M
Busway Systems Overview
Selector Chart (20-6500 Ampere)I-T-E was the first manufacturer to makea Busway System then known asBulldog Electric. Since its introduction in
Busway Selector Chart20-6500 Ampere
1932, Busway Systems have improvedand expanded into several designs tomeet the ever changing needs of the
GENERAL
electrical industry. The Busway SelectionChart below will help you in selecting theproper product to fit your requirements.
600 Volts or Less
Feature
AmpereRating
Conductor
Use
AC Service
DC Service
Voltage
Construction
MeetsElectricalStandard
1001502002253754005006008001000
1200
1350
1600
200025003000400050006000, 6500CopperAluminumIndoorOutdoor2W103W
303W304W FN304W 200% N2-W3-W125250300600 volts or lessVentilatedNon-Ventilated
ANSI UL857-1996®NEMA BU1-1999IEEE STD27 (ANSI 37.20)
NO 0-M1982CSA NO 0.4-M1982C22.2 NO *4-M1985
NO 27-197360439-1
IEC 60439-2PUBL. 1445486-Part 2: 1988159(1972)
JIS C8364400 Hz®D.C.®NEC-1993®NEMA G8-2, 1972, Part 14
ProductBustributionPlug-in and Feeder BuswaySiemens SentronPlug-in/Feeder
i
/yJJJJ1
J
yij
jjyiV
•JJJ
J
J
JyyV
yyyyyyyyyyyy
SentronLow Amp
/*;
y/y
yy
y
y
y
yyy
yy
yyyy/v'
yyy/V
yyy/
v'
XL-UPlug-in Feeder
y/
V*
y/•jjy
yyyy
yyyyj
yyy
yy
yy
y
y/
v/
/
yyy
yy©©©©©©yyj/̂
XJ-LPlug-in
y
y
/
yy
yyy
yyyy
y
vyy©®CD
®
©
®
y/y
BDPlug-in
yy
yyyy.yy
yyy
yyy
y
yy
v''
yy^j®®®©®®
/>/
IndustrialTrol-E-Duct/
yyyyyyyy
y
y
y
yyyy
y
y
y
y
yy
BT
C/3 CO•< c</> <n
tn "*
© Meets most applicable provisions of thisforeign standard.
9Used on both DC and 400Hz applications. Consultfactory for information.
©When busway is installed per manufacturer's recommen-dations, Siemens busway meets all applicable portions.
Siemens Electrical Products SPEEDFAX 2000