burndy grounding

Download BURNDY Grounding

Post on 18-Oct-2015

220 views

Category:

Documents

0 download

Embed Size (px)

DESCRIPTION

CONNECTORS

TRANSCRIPT

  • BURNDY ProductsGrounding

    D-1

    TABLE OF CONTENTSHYGROUND IRREVERSIBLE COMPRESSION GROUNDING

    AND INSTALLATION TOOLING

    Type YGIB .....................D-20 - D-21

    Type GSTUD-HY .......................D-22

    Types YGT & YTTAG ................D-23

    Type YG-B..................................D-24

    MECHANICAL GROUNDINGTypes KC, K2C .........................D-25

    Types KC22J12T13,EQC632C, KS-DB ..................D-26

    Types KS, GKA,KPB, CL50-1............................D-27

    Type GAR ......................D-28 - D-29

    Types GAR-BU & GAR 3900 Series & GAR-RB .........D-30

    Type GAR-TC ...........................D-31

    HYGROUND Features and Benefits ...................D-5 - D-6

    Type YGL-C ................................D-7

    Type YGLR-C ..............................D-8

    Type YGHP-C .............................D-9

    Type YGHP-C ...........................D-10

    Type YGHC-C ...........................D-11

    Type YGC ..................................D-12

    Type YSHG ................................D-13

    Type YGHR-C .......................... D-14

    Type YGHR-C ..........................D-15

    Type YGHA ...............................D-16

    Type YGHS ...............................D-16

    Type YGA ..................................D-17

    Type YGS ..................................D-18

    Type YGF ..................................D-19

    LIGHTNING PROTECTION INFO.Basic rules for selection are:1. Must be like material to the conductor.2. Two bolts to ground rod minimum, for mechanical.3. Cable to cable connections can be installed with one bolt,

    two bolt, or compression.4. Cable to steel structure must have 8 in.2 contact with steel.5. Heavy duty stacks mechanical only.6. On all connectors with heavy duty stack rating, we must

    offer 1/16 thick lead plating as an option. Reason is closest25 ft. to stack opening must use lead coated product.

    7. UL 96 Listing.

  • BURNDY ProductsGrounding

    D-2

    TABLE OF CONTENTSMECHANICAL GROUNDING (Continued)

    Types GC, GCM ........................D-47

    Type GL ....................................D-48

    Type GZ ....................................D-48

    Type GC-CT ..............................D-49

    Type GIE-G ...............................D-50

    Rail Connector ..........................D-51

    Type QGFL ...............................D-52

    Type GA-H ................................D-52

    Type GRF ..................................D-53Raised Floor Grounding

    Types GP-G1, GPRT..................D-54Raised Floor Grounding

    Type GD ....................................D-32

    Type GP ....................................D-33

    Type GK ....................................D-33

    Water Pipe Grounding ..D-34 - D-39

    Type GC-A ................................D-40

    Type GG ....................................D-41

    Type GQ ....................................D-42

    Type GX ....................................D-43

    Types GRC, GRL ......................D-44

    Type B ............................D-45 - D-46

    Types GB, GBM ........................D-47

  • BURNDY ProductsGrounding

    D-3

    TABLE OF CONTENTSBURNDYWeld

    BURNDY WeldIntroduction ................................D-56

    Making a BURNDYWeldConnection ..........................D-57

    WELD METAL ..........................D-58

    Type BCC-1 ..............................D-59

    Type BCC-2 ..............................D-60

    Type BCC-4 ..............................D-61

    Type BCC-11 ............................D-62

    Type BCC-6 ..............................D-63

    Type BCC-14 ............................D-63

    Type BCC-7 ..............................D-64

    Type BCR-1................................D-65

    Type BCR-2 ............................. D-66

    Type BCR-3 .............................D-67

    Type BCR-17 ............................D-68

    Type BCR-24 ............................D-69

    Type BCS-1 ...............................D-71

    Type BCS-8 ...............................D-71

    Type BCS-2 ...............................D-72

    Type BCS-9 ...............................D-72

    Type BCS-3 ...............................D-73

    Type BCS-23 .............................D-74

    Type BCS-4 ...............................D-75

    Type BCS-6 ...............................D-75

    Type BCS-7................................D-76

    Type BCS-18 .............................D-76

    Type BCS-5 ...............................D-77

    Type BCRE-1 ............................D-78

    Type BCRE-2 ............................D-79

  • BURNDY ProductsGrounding

    D-4

    TABLE OF CONTENTSBURNDYWeld (Continued)

    Type BCRE-3 ............................D-80

    Type BCRE-4 ............................D-81

    Type BCRE-6 ............................D-82

    BURNDYWeld FILL ..............D-83

    BURNDYWeld SET ...............D-85

    BURNDYWeld Prefabricated Wire Mesh .............................D-87

    Types B-106 & B-107Handle Clamps .....................D-89

    B40-0106-75Handle Attachment ...............D-89

    Mold Support Clamp .................D-89

    Vertical MagneticClamps ..................................D-90

    Horizontal & VerticalChain Clamps .......................D-90

    SINGLE SHOT MOLDSType BCR-1 ..............................D-70

    Type BCR-2 ..............................D-70

    Type BCR-24 ............................D-70

    Type BCR-25 ............................D-70

    ACCESSORIESB38-0330-00 Cable Clamp .......D-91

    Cable Cleaning Brush ...............D-91

    Card Cloth Brush ......................D-91

    Mold Cleaning Brush ................D-91

    Mold Cleaners ...........................D-91

    Packing Material ........................D-91

    BURNDYWeld Tool Kit ..........D-92

    BURNDYWeld Tools ..............D-92

    B38-0101-00 Rasp ....................D-92

    B38-0309-00 Flint Ignitor ..........D-92

    Ground Rod Driving Sleeves .....................D-93

    Shim Stock and Adapter Sleeves ....................D-93

    Tips ..................................D-94 - D95

  • BURNDY ProductsGrounding

    THE HYGROUNDIRREVERSIBLECOMPRESSIONSYSTEMBURNDY has developed an irreversiblecompression ground system which meets themost stringent safety and performancerequirements, including those of OSHA andnuclear power plant design. Performanceexcellence and long life expectancy are thesystems basic design guidelines. It is a com-plete system which consists of connectors forgrid cross connections, taps, splices, cable toground rod, ground plates and terminations.

    Our irreversible compression ground connec-tors employ well-proven design principlesand technology that have been in existencefor over 60 years.

    Connectors are just one component of ourIrreversible Compression Ground System.Installation tooling is also an integral part ofthis system. BURNDY pioneered the com-pression connector principle and continuestoday to be the leader in compression tech-nology. Our tooling package is the mostextensive in the industry and affords the usermany options.

    D-5

  • BURNDY ProductsGrounding

    THE HYGROUNDIRREVERSIBLECOMPRESSIONSYSTEM(Continued)

    D-6

    Features and Benefits Irreversible compression.9 Meets 1999 NEC code, section 250-50

    and 250-64. Material-pure wrought copper extrusions,

    rod and seamless tubingidenticalmaterial to the conductor.9 Completely eliminates the possibility of

    corrosion due to dissimilar metals. Heavy duty connector design.9 All connectors will carry the equivalent

    or greater current carrying capacity of the conductor while maintaining high mechanical strength and electrical integrity.

    Range taking designminimum number ofconnector combinations required to installa conductor range of #6 solid to 500 kcmilplus 1/2, 5/8, 3/4, and 1 ground rodsand rebar.9 Inventories are kept to a minimum and

    product selection is simplified. System engineered tooling.9 Each tooling recommendation has

    been designed to ensure reliability of the connection.

    Irreversible compression connectors can be installed in all kinds of weather.9 Eliminates costly construction delays

    and enables the installer to better schedule his job.

    May be installed without special training or special tools. Y750 crimps entire range.9 Low installed cost.

    Simplified installation. Each connection can be made in less than

    3 minutes.9 Low installed cost.

    Simplified installation. Each connector is clearly marked with

    catalog number, conductor size and installation die information.9 Easy and accurate identification.

    Inspection ports are provided to assureproper insertion of the conductor.9 Built-in quality assurance.

    The die index number is embossed on theconnector after completion of the crimp.9 Facilitates speedy inspection of installed

    connectors to insure consistently reliableand sound connections.

    Most HYGROUND irreversible compres-sion elements are prefilled with PENETROX and individually sealed in clear polyethylene sheet.9 Ensures that all contact surfaces are in

    the proper condition for installation.9 Ensures the electrical integrity of the

    finished connection by inhibiting moistureand contaminates from entering thecontact area.

    All HYGROUND irreversible compres-sion connectors are Listed in conformancewith Underwriters Laboratories StandardUL467 and conform to applicable sectionsof the National Electrical Code.9 May be used in direct burial or concrete

    embedded grounding applicati