builders series

4
TM The Optimum Multi-Family Heating & Cooling Solution Builders Series Fan Coils

Upload: energy-saving-products-ltd

Post on 18-Mar-2016

223 views

Category:

Documents


0 download

DESCRIPTION

Hi-Velocity Systems Builders Series Bi-Fold Brochure

TRANSCRIPT

Page 1: Builders Series

TM

Re-Defining the Hi-Velocity System

Manufactured by

Call 1-888-652-2219 or Visit Us At

The OptimumMulti-Family

Heating & Cooling Solution

Builders Series Fan Coils

Model HE-51 HE-52 HE - 71 HE - 101Hot Water Heating

Coil Type 6 Row/10 FPI 4 Row/12 FPI 6 Row/10 FPI 6 Row/10 FPI

BTUH @ 190° E.W.TBTUH @ 180° E.W.TBTUH @ 170° E.W.TBTUH @ 160° E.W.TBTUH @ 150° E.W.TBTUH @ 140° E.W.TBTUH @ 130° E.W.TBTUH @ 120° E.W.TBTUH @ 110° E.W.T

GPM Flow ratingsPressure Drop FT. H2OCFM @ 68° E.A.T

59,40054,50049,60044,60039,70034,70029,70024,80020,100

53

470

50,90046,70042,50038,30034,10029,80025,50021,30017,200

55

470

89,20081,80074,40067,10059,70051,80044,70037,40030,300

76.5700

134,000122,900111,800100,70089,70078,40067,10056,20045,500

106.8

1120

Chilled Water CoolingCoil Type 6 Row/10 FPI 6 Row/10 FPI 6 Row/10 FPI(WCM Modules in cooling Mode)

BTUH @ 48°F E.W.T.BTUH @ 46°F E.W.T.BTUH @ 44°F E.W.T.BTUH @ 42°F E.W.T.BTUH @ 40°F E.W.T.

(WCM Modules in Heating Mode)BTUH @ 150° E.W.TBTUH @ 140° E.W.TBTUH @ 130° E.W.TBTUH @ 120° E.W.TBTUH @ 110° E.W.T

GPM Flow ratingsPressure Drop FT. H2O

19,30020,90022,60024,20025,800

39,70034,70029,70024,80020,100

53

27,00029,40031,80034,00036,400

59,70051,80044,70037,40030,300

76.5

42,10045,80049,50053,20056,800

89,70078,40067,10056,20045,500

106.8

Refrigerant CoolingRPM-E Modules(1)

BTUH Refrigerant TX Cooling (tons) 1.5 - 2.0 1.5 - 2.0 2.5 - 3.0 3.5 - 5.0

Electrical HeatingKilowatt Range 5 - 15 Kw N/A 5 - 18 Kw 5 - 23 Kw

Voltage

Max Rated C.F.M.Horse PowerR.P.M.Integral Surge and Fuse SystemSupply Air SizeSupply Maximum Length(2)

Return Size Needed

115/230/1/50/60 F.L.A. 8 amp

5203/4

VariableYes

8” round70’

12” (113 in2)

5203/4

VariableYes

2 x 6” or 1 x 8”50’

12” (113 in2)

7703/4

VariableYes

8” round80’

12” (113 in2)

12603/4

VariableYes

10” round100’

14” (154 in2)

Minimum Outlets(3)

Maximum Outlets1224

1224

2032

2852

(2) Maximum length is from the unit to the supply end run cap. More than one run per unit is allowable.(1)Smaller condensers may be matched to the fan coil when needed (match TXV to condenser size.)

(3)Minimum of 8 full outlets per ton of cooling needed.

www.hi–velocity.comESP 102.06b-HE

HARDI

P R O U D M E M B E R O F

Page 2: Builders Series

Manufactured by

Save On Installation Costs

Improved Indoor Air Quality•Draftfreeheatingandcooling•Eventemperaturesineveryroom•Constantflowaircirculationhelpseliminatedust

Apartment Construction• Quick & Easy Installation

• Eliminates most drywall bulkheads•Adjustable vents maximize air control

• Flexible vent locations, air distribution from ceiling, floor or sidewall• 2” & HE flexible ducts

Third Party Components Easily Added•Humidifiers•Hi-Efficiencyfilters•HRV/ERV’s

Space Saver Unit•Socompactitfitsintoacloset•5possiblesupplyoutlets•Can be installed in mechanical rooms,crawlspaces,closetsorattics

Townhouse Construction

When Every Square Foot Matters, Count On Hi-Velocity SystemsTM!

Electronic Performance Controlled (EPC) Motors•Hi-Efficiency, reduce operating costs up to 50%•Automatic Voltage & Frequency Recognition

110 / 230 volt, 50 / 60 Cycle•Programmablevariablefrequencymotor,utilizingmassflowtechnologytosupply1.5to5tons(5.3to17.6Kw)airflow

•6 independent speeds1. Hi-Cooling2. Low-Cooling3. Dehumidification4. Hi-Heating5. Low-Heating6. Constantairflow

• Zoning Friendly

Single Side Access Fan Coils•Cooling capacities ranging from:

1.5 to 5 tons (5.3 to 17.6 Kw)•Heating capacities up to:

140,000 btuh (41 Kw)•Optional heating coil simply slides in place•Comespre-wiredforheating,cooling,dehumidification

and ventilation so no additional controls are needed• Installs, Vertically, Horizontally, Counter-Flow

Page 3: Builders Series

Manufactured by

Save On Installation Costs

Improved Indoor Air Quality•Draftfreeheatingandcooling•Eventemperaturesineveryroom•Constantflowaircirculationhelpseliminatedust

Apartment Construction• Quick & Easy Installation

• Eliminates most drywall bulkheads•Adjustable vents maximize air control

• Flexible vent locations, air distribution from ceiling, floor or sidewall• 2” & HE flexible ducts

Third Party Components Easily Added•Humidifiers•Hi-Efficiencyfilters•HRV/ERV’s

Space Saver Unit•Socompactitfitsintoacloset•5possiblesupplyoutlets•Can be installed in mechanical rooms,crawlspaces,closetsorattics

Townhouse Construction

When Every Square Foot Matters, Count On Hi-Velocity SystemsTM!

Electronic Performance Controlled (EPC) Motors•Hi-Efficiency, reduce operating costs up to 50%•Automatic Voltage & Frequency Recognition

110 / 230 volt, 50 / 60 Cycle•Programmablevariablefrequencymotor,utilizingmassflowtechnologytosupply1.5to5tons(5.3to17.6Kw)airflow

•6 independent speeds1. Hi-Cooling2. Low-Cooling3. Dehumidification4. Hi-Heating5. Low-Heating6. Constantairflow

• Zoning Friendly

Single Side Access Fan Coils•Cooling capacities ranging from:

1.5 to 5 tons (5.3 to 17.6 Kw)•Heating capacities up to:

140,000 btuh (41 Kw)•Optional heating coil simply slides in place•Comespre-wiredforheating,cooling,dehumidification

and ventilation so no additional controls are needed• Installs, Vertically, Horizontally, Counter-Flow

Page 4: Builders Series

TM

Re-Defining the Hi-Velocity System

Manufactured by

Call 1-888-652-2219 or Visit Us At

The OptimumMulti-Family

Heating & Cooling Solution

Builders Series Fan Coils

Model HE-51 HE-52 HE - 71 HE - 101Hot Water Heating

Coil Type 6 Row/10 FPI 4 Row/12 FPI 6 Row/10 FPI 6 Row/10 FPI

BTUH @ 190° E.W.TBTUH @ 180° E.W.TBTUH @ 170° E.W.TBTUH @ 160° E.W.TBTUH @ 150° E.W.TBTUH @ 140° E.W.TBTUH @ 130° E.W.TBTUH @ 120° E.W.TBTUH @ 110° E.W.T

GPM Flow ratingsPressure Drop FT. H2OCFM @ 68° E.A.T

59,40054,50049,60044,60039,70034,70029,70024,80020,100

53

470

50,90046,70042,50038,30034,10029,80025,50021,30017,200

55

470

89,20081,80074,40067,10059,70051,80044,70037,40030,300

76.5700

134,000122,900111,800100,70089,70078,40067,10056,20045,500

106.8

1120

Chilled Water CoolingCoil Type 6 Row/10 FPI 6 Row/10 FPI 6 Row/10 FPI(WCM Modules in cooling Mode)

BTUH @ 48°F E.W.T.BTUH @ 46°F E.W.T.BTUH @ 44°F E.W.T.BTUH @ 42°F E.W.T.BTUH @ 40°F E.W.T.

(WCM Modules in Heating Mode)BTUH @ 150° E.W.TBTUH @ 140° E.W.TBTUH @ 130° E.W.TBTUH @ 120° E.W.TBTUH @ 110° E.W.T

GPM Flow ratingsPressure Drop FT. H2O

19,30020,90022,60024,20025,800

39,70034,70029,70024,80020,100

53

27,00029,40031,80034,00036,400

59,70051,80044,70037,40030,300

76.5

42,10045,80049,50053,20056,800

89,70078,40067,10056,20045,500

106.8

Refrigerant CoolingRPM-E Modules(1)

BTUH Refrigerant TX Cooling (tons) 1.5 - 2.0 1.5 - 2.0 2.5 - 3.0 3.5 - 5.0

Electrical HeatingKilowatt Range 5 - 15 Kw N/A 5 - 18 Kw 5 - 23 Kw

Voltage

Max Rated C.F.M.Horse PowerR.P.M.Integral Surge and Fuse SystemSupply Air SizeSupply Maximum Length(2)

Return Size Needed

115/230/1/50/60 F.L.A. 8 amp

5203/4

VariableYes

8” round70’

12” (113 in2)

5203/4

VariableYes

2 x 6” or 1 x 8”50’

12” (113 in2)

7703/4

VariableYes

8” round80’

12” (113 in2)

12603/4

VariableYes

10” round100’

14” (154 in2)

Minimum Outlets(3)

Maximum Outlets1224

1224

2032

2852

(2) Maximum length is from the unit to the supply end run cap. More than one run per unit is allowable.(1)Smaller condensers may be matched to the fan coil when needed (match TXV to condenser size.)

(3)Minimum of 8 full outlets per ton of cooling needed.

www.hi–velocity.comESP 102.06b-HE

HARDI