book of abstracts of cost fp 1404 mc and wg meeting action fp1404 fire safe use of bio-based...

83
COST Action FP1404 Fire Safe Use of Bio-Based Building Products Book of abstracts of COST FP 1404 MC and WG meeting: Dissemination, standardization and implementation of novel improvements” Prague, Czech Republic 2 – 3 February 2017 Editors: Tomaž Hozjan, David Lange and Peter Kuklik Organiser: Czech Technical University in Prague, Faculty of Civil Engineering, Thákurova 7/2077, 166 29 Prague 6, Czech Republic. Chair of the Action: Joachim Schmid Vice Chair of the Action: Massimo Fragiacomo

Upload: doanliem

Post on 26-May-2018

214 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Book of abstracts of COST FP 1404 MC and WG meeting Action FP1404 Fire Safe Use of Bio-Based Building Products Book of abstracts of COST FP 1404 MC and WG meeting: ”Dissemination,

COST Action FP1404

Fire Safe Use of Bio-Based Building Products

Book of abstracts of COST FP 1404 MC and WG meeting:

”Dissemination, standardization and implementation of novel improvements”

Prague, Czech Republic

2 – 3 February 2017

Editors: Tomaž Hozjan, David Lange and Peter Kuklik Organiser: Czech Technical University in Prague, Faculty of Civil Engineering,

Thákurova 7/2077, 166 29 Prague 6, Czech Republic.

Chair of the Action: Joachim Schmid Vice Chair of the Action: Massimo Fragiacomo

Page 2: Book of abstracts of COST FP 1404 MC and WG meeting Action FP1404 Fire Safe Use of Bio-Based Building Products Book of abstracts of COST FP 1404 MC and WG meeting: ”Dissemination,

Book of abstracts of COST FP 1404 MC and WG meeting: ”Dissemination,

standardization and implementation of novel improvements”

Editors:

Tomaž Hozjan, David Lange and Peter Kuklik

Copyright:

RISE Research institutes of Sweden, Transport and Safety / Fire Research and the

individual authors of each abstract.

All rights reserved. No part of this publication may be reproduced, stored in a

retrieval system, or transmitted, in any form or by any means, electronic,

mechanical, photocopying, recording or otherwise, without the prior permission of

the publishers.

Neither the COST Association nor any person acting on its behalf is responsible for

the use, which might be made of the information contained in this publication. The

COST Association is not responsible for the external websites referred to in this

publication.

This book may be cited as:

Hozjan, T., Lange, D. and Kuklik, P. (eds.) (2017)

Book of abstracts of COST FP 1404 MC and WG meeting: ”Dissemination,

standardization and implementation of novel improvements”.

SP Report 2017:20, ISBN 978-91-88349-91-0

RISE Research Institutes of Sweden

SP Report 2017:20

ISBN 978-91-88349-91-0

ISSN 0284-5172

Borås 2017

Page 3: Book of abstracts of COST FP 1404 MC and WG meeting Action FP1404 Fire Safe Use of Bio-Based Building Products Book of abstracts of COST FP 1404 MC and WG meeting: ”Dissemination,

Table of Contents

PREFACE I

WORKING GROUP 1 1

SMOULDERING BEHAVIOUR OF BIO-BASED BUILDING MATERIALS Rory M. Hadden 2

STATE-OF-THE-ART ABOUT HOW REAL FIRES MAY BE INFLUENCED BY STRUCTURE Koji Kagiya, Norman Werther 3

UPDATE ON RECENT ACTIVITIES IN WG1 – TG1: “REACTION TO FIRE PERFORMANCE AND INPUT PARAMETERS FOR SIMULATION PURPOSES” Dionysios I. Kolaitis 10

CAN WE PREDICT THE CHARRING RATE? OPPORTUNITIES AND CHALLENGES IN COMPUTATIONAL PYROLYSIS OF TIMBER Franz Richter, Guillermo Rein 13

FUNDAMENTAL PROPERTIES OF BIO-BASED MATERIALS FOR STATE-OF-THE-ART MODELING OF REACTION TO FIRE PERFORMANCE Davood Zeinali 15

THE INFLUENCE OF DIFFERENT FUNDAMENTAL MATERIAL PROPERTIES ON THE PYROLYSIS OF MEDIUM DENSITY FIBERBOARD – A SENSITIVITY ANALYSIS BY FDS G. Zhao, T. Beji, D. Zeinali, B. Merci 17

WORKING GROUP 2 19

REVIEW AND DETERMINATION OF FIRE RESISTANCE RATINGS FOR GLULAM CONNECTORS David Barber 20

FIRE PART OF EUROCODE 5 EN 1995-1-2 - REVISION STATUS AND PERSPECTIVE Andrea Frangi 24

SHORT REVIEW OF THE RESEARCH CONDUCTED ON THE FIRE BEHAVIOUR OF TIMBER-CONCRETE COMPOSITE SYSTEMS Tomaž Hozjan, Anita Ogrin, Michael Klippel 28

FIRE SAFETY OF TIMBER BUILDINGS UNDER CONSTRUCTION – OVERVIEW OF GUIDELINES AND RECOMMENDATIONS Yves Martin, Michael Klippel, Jan Gmür, Eliott Odermatt 31

SIMULATION OF CHARRING DEPTH OF WOODEN-BASED PRODUCTS WHEN EXPOSED TO NATURAL FIRE CURVES Jean-Christophe Mindeguia 38

Page 4: Book of abstracts of COST FP 1404 MC and WG meeting Action FP1404 Fire Safe Use of Bio-Based Building Products Book of abstracts of COST FP 1404 MC and WG meeting: ”Dissemination,

FIRE BEHAVIOUR AND DESIGN OF BEAM‐TO‐COLUMN STEEL‐TO‐TIMBER DOWELLED CONNECTIONS Pedro Palma, Andrea Frangi 40

Current state of working group 2: Fire behaviour of CLT Michael Klippel, Norman Werther, Birgit Östman 43

WORKING GROUP 3 46

REPORT ON BUILDING REGULATION CONCERNING THE BIO BASED BUILDING PRODUCTS IN HUNGARY Tamás Herzeg 47

FIRE-FIGHTING CONCEPTS FOR BUILDINGS MADE FROM BIO-BASED PRODUCTS Kamila Kempná, Jan Smolka, Miloš Kvarčák 49

CONSTRUCTION SITE FIRE SAFETY – UK EXPERIENCE Tom Lennon 51

BACKGROUND TO BUILDING REGULATIONS – CHANGE OF FIRE SAFETY REGULATIONS IN FINLAND Esko Mikolla 53

SERBIA: FIRE SAFETY IN REGULATIONS, RESEARCH AND FUTURE CHALLENGES Mirjana Laban, Tatjana Kočetov Mišulić, Suzana Draganić, Igor Dzolev 57

DESIGNERS’ OPINIONS ON THE USE OF BIO-BASED MATERIALS IN BUILDINGS Andrew Macilwraith, Maria Pilar Giraldo, Kathinka Leikanger Friquin, Ayfer Donmez Cavdar 61

REGULATORS’ VIEWS ON THE USE OF BIO-BASED MATERIALS IN BUILDINGS Andrew Macilwraith, Maria Pilar Giraldo, Kathinka Leikanger Friquin, Ayfer Donmez Cavdar 67

WORKING GROUP 4 73

FIRST COST ACTION FP1404 TRAINING SCHOOL – FIRE SAFE USE OF BIO-BASED MATERIALS – UNIVERSITY OF EDINBURGH, UK Rory Hadden, Luke Bisby, Felix Wiesner, Nikolai Gerasimov, Alastair Bartlett 74

Page 5: Book of abstracts of COST FP 1404 MC and WG meeting Action FP1404 Fire Safe Use of Bio-Based Building Products Book of abstracts of COST FP 1404 MC and WG meeting: ”Dissemination,

I

Dear experts,

The meeting in Prague represents a mile-stone of the COST Action FP1404, Fire Safe Use of Bio-

Based Building Products. In the last two years, 13 task groups and about 150 documents have

been created, and the programme was supported by the EU with about 150.000€.

Researchers sometimes consider COST Actions as a network of travellers rather than active

experts. As chair and vice chair of this Action we also had this concern at the beginning, but at this

point in time we can report on very active groups which have created not only a range of useful

outputs but also a platform for stimulating exchange of information and creative energy, which

has been acknowledged by several experts so far. However, without individual commitment and

team work, possibilities for this inspiring environment are limited. We do hope that you have

found your task group within this COST Action that gives you vitality to make your business area

and your country to push the borders for sustainable bio-based building materials while ensuring

the fire safety of these exciting new buildings.

The meeting in Prague attracted about 60 experts from all over the world including Canada and

Japan. Presentations were given on national challenges and state-of-the-art in fire safe use of bio-

based building products of countries that recently joined the Action. Highly specialized

contributions were also delivered on firefighting and experiences of tests with combustible

materials.

Together with the WG4 leaders, we collected the abstracts within this book to provide the experts

with information on different areas. We hope you will continue to work with us for the next two

years and contribute to the success of this Action.

This book contains proceedings of the annual COST Actions meeting in Prague and includes 17

abstracts from different themes covering the topics of technical working groups of the COST

action FP1404 and 1 abstract covering the report from the training school held at the University of

Edinburgh, UK, 2016. This book of abstracts has been subdivided into following themes:

WG1 - Contribution of bio-based materials to the fire development

WG2 - Structural Elements made of bio-based building materials and detailing

WG3 - Regulations for fire safety of bio-based building materials

WG4 - Dissemination

Dest Regards,

Joachim Schmid, chair of FP1404

Massimo Fragiacomo, vice-chair of FP1404

Tomaž Hozjan and David Lange, WG4 Leaders

Page 6: Book of abstracts of COST FP 1404 MC and WG meeting Action FP1404 Fire Safe Use of Bio-Based Building Products Book of abstracts of COST FP 1404 MC and WG meeting: ”Dissemination,

1

Working Group 1

Contribution of bio-based materials to the fire development

Page 7: Book of abstracts of COST FP 1404 MC and WG meeting Action FP1404 Fire Safe Use of Bio-Based Building Products Book of abstracts of COST FP 1404 MC and WG meeting: ”Dissemination,

2

Smouldering behaviour of bio-based building materials

Rory M. Hadden

School of Engineering, University of Edinburgh, UK, [email protected]

Keywords: pyrolysis, oxidation, timber, hemp, cellulosic materials

Smouldering combustion is the slow, low temperature flameless form of combustion sustained by

the heat evolved from the heterogeneous oxidation of solid fuels [1]. Typically smouldering has

not been considered a substantial risk to constriction materials however, the adoption of

cellulose-based materials requires that the risks posed by smouldering are explicitly addressed.

This presentation will briefly discuss the process of smouldering combustion, some of the unique

challenges associated with bio-based building materials and highlight some work underway to

develop mitigation strategies. The talk will discuss the implications of smouldering on timber

construction and hemp-based insulation materials [2]. Work underway at the University of

Edinburgh at TWU (UK) to investigate the ability of novel, silica-based nanoparticles to reduce the

risk of smouldering will also be presented. An overview of recent regulatory developments [3] will

be given and areas of emerging risk discussed.

References:

[1] M. S. Mclaggan, Novel fire testing frameworks for Phase Change Materials and hemp-lime

insulation, PhD Thesis, The University of Edinburgh, 2016.

[2] T.J. Ohlemiller. SFPE Fire Protection Handbook, Chapter 2–10: Smouldering Combustion, 3rd

ed., National Fire Protection Association, Quincy, MA 02269, 2002, pp. 2–201–2–210.

[3] British Standards Institution. (2016). BS EN 16733:2016: Reaction to fire tests for building

products — Determination of a building product's propensity to undergo continuous smouldering

Page 8: Book of abstracts of COST FP 1404 MC and WG meeting Action FP1404 Fire Safe Use of Bio-Based Building Products Book of abstracts of COST FP 1404 MC and WG meeting: ”Dissemination,

3

State-of-the-art about how real fires may be influenced by

structure

Koji Kagiya1, Norman Werther2

1 Building Research Institute, Japan 2 TU Munich Chair for Timber Structures and Building Construction

Keywords: timber, natural fire, literature review, SOA

Following summary gives an overview of fire tests, research studies and fire incidents where bio

based building materials (BBBM) have been involved with respect to observations and results

about the potential contribution of bio based building materials to the fire scenario.

This documentation aims to help in understanding the influence of BBBM in each stage of the fire

and to an overall fire safety.

This knowledge is needed to quantify the risk in using BBBM and in order to add or develop

passive and/or active measures to guarantee fire safe buildings.

The potential influences can be summarised as follows and are derived from the table below:

• the presence of BBBM increase the smoke production rate and most dominant in under-

ventilated scenarios or smouldering fires the production of toxic gases, in particularly in

the early stage of fire,

• combustible linings can lower the time to flash over,

• the presence of combustible linings can increase the fire severity and heat release, but

does not necessarily lead to increased peak temperatures in fully developed fires, the

influence is less pronounced if only the ceiling or a single wall is unprotected,

• the contribution of combustible linings can postpone the decay of fire, however self-

extinguishment may also possible even combustible linings are present

• multiple flash overs may cause if delamination of unprotected CLT or falling down of a

protection lining occur,

• intense flaming combustion outside the windows may occur in ventilation controlled

compartment fires

• a thread for rapid fire spread and large fire incidents within the erecting phase of building

exist, in particular for light timber frame structure when protective lining is not in place

However, several projects in recent years have shown, that considering these potential influences

adequate within the design process fire safety will be reached even if bio based building products

are used. A further detailed description about measures to exclude and compensate these

potential influences will be part of further publications within the COST action FP1404..

Page 9: Book of abstracts of COST FP 1404 MC and WG meeting Action FP1404 Fire Safe Use of Bio-Based Building Products Book of abstracts of COST FP 1404 MC and WG meeting: ”Dissemination,

Country

(Date)

References Type of fire

(real/ fire test)

Real Fire Full Scale fire test Potential contribution of BBBM to fire

behaviour

Building Compartment Building Compartment

SE Karlsson et al. (1992) Analysis of 24 fire tests

with different lining

materials

✔ • for combustible linings compartment

temperatures under the ceiling in pre flash

over fires can be determined by multiply

following equation by factor 2

USA Tewarson (2002) ASTM E2058 fire

propagation apparatus

tests with respect of

combustion efficiency and

toxic hazard of materials

• under ventilated combustion (equivalence

ration >1) result in excessive production of

toxic gases e.g. CO

UK (1995) Lennon et al. (2000)

Bullock et al.

“TF2000 project”

Fire test of a 6-storey

residential building

✔ ✔ • fire and smoke spread via egress route,

• timber structure of the stair and shaft

contributed to the fire event (insignificant)

A(< 1999) Dowling et al. (1999)

Wade (2001)

ISO 9705 and room /

corridor tests with

different lining materials

✔ • plywood lining reduced time to flash over

and increased heat release and smoke

production

• ISO 9705 room:

wall + ceiling (125s), wall only (163s), ceiling

only (400s)

CH (1999) Maag et al. (2000)

Frangi (2005)

Timber frame

compartment fire tests

✔ ✔ pre flashover:

• no contribution of combustible linings in

sprinklered compartment

4

Page 10: Book of abstracts of COST FP 1404 MC and WG meeting Action FP1404 Fire Safe Use of Bio-Based Building Products Book of abstracts of COST FP 1404 MC and WG meeting: ”Dissemination,

“wooden modular

hotels”

with different linings (pre-

and post-flashover)

post flashover:

• rapid flashover, combustible lings increased

fire plume outside the window, no

significant temp. differences

• rear ventilated caps in combustible façade

will contribute to an increased fire spread

JPN (2000) Kagiya et al. (2002) Fire of a large glulam

gymnasium

✔ • Flashover in a large enclosure

FI (2002) Hakkarainen (2002)

Four compartment fire

tests with different linings

• no increase in compartment temperature

• release of additional pyrolysis gases and

increased fire plume (heat flux) in front the

façade

• extension of the phase of the fully

developed fire (delay of the decay phase)

GER (2004) Hegemann (2004) Full scale test to evaluate

the influence of

combustible linings

✔ • extended fire duration and larger fire plume

outside the window within the compartment

with combustible linings

UK (2006) Schneider et al. (2007)

Bregulla et al. (2010)

“Colindale fire“

Fire in Beaufort Park

building site of a large

timber frame building

✔ • fire protection lining and separating

elements only partly finished - allowed a

rapid fire spread, size of the fire

uncontrollable for fire service

JPN (2006) Frangi et al. (2008) Full scale fire tests of

compartment fires

✔ ✔ • Excessive burning outside window after

lining failed

GER (2006) Winter et al. (2009) Full scale fire tests to ✔ ✔ • continuous gaps and voids in contact with

combustible materials promoted the spread

of fire

5

Page 11: Book of abstracts of COST FP 1404 MC and WG meeting Action FP1404 Fire Safe Use of Bio-Based Building Products Book of abstracts of COST FP 1404 MC and WG meeting: ”Dissemination,

evaluate flame spread

mechanism in timber

buildings

AT (2010) Feuerwehr Salzburg

(2010)

"Brand Stabauergasse

Salzburg“

Fire in 3 storey timber

frame apartment building

✔ • fire spread via eave within an unseparated

roof structure

• Smoldering fires within void cavities

CAN (2011) Sherlock et al. (2011) Fire in the “Remy”

housing project in

Richmond Canada, timber

frame structure with 81

units under construction

✔ • rapid fire spread, buildings were fully

engulfed by flames when fire service arrived

• wood contributed to the severity of the fire

(citation chief of fire & rescue service)

JPN

(2011-2013)

Hasemi et al. (2014)

Suzuki et al. (2016)

Fire tests of a 3-storey

wooden school building

(3 tests)

✔ ✔ • rapid fire spread by ejected flame

• severe heating to structural timber elements

• charring rate of timber column in natural fire

JPN

(2011-)

Watanabe et al. (2015)

Naruse et al, (2015)

Full scale fire tests of

compartment fires

✔ •

• floor area, opening, location and surface

area of wood

AUS (2011) England et al. (2011) Literature review, risk ✔ • no difference in the fire tests between

compartments with lined steel and timber

6

Page 12: Book of abstracts of COST FP 1404 MC and WG meeting Action FP1404 Fire Safe Use of Bio-Based Building Products Book of abstracts of COST FP 1404 MC and WG meeting: ”Dissemination,

assessment and fire tests studs found

• estimations about a maximum increase in

the fire load due to the light timber frame

between 4 – 20%

SE

(2013)

Östman and Stehn, SP

Rapport 2014:07

Fires in a residential

timber building

✔ • fire growth via cavity of walls after initial fire

CAN (2012) McGregor (2013) Fire tests in protected and

unprotected CLT

compartments

✔ • initially unprotected CLT or when protective

lining failed - panels contributed to the fire

intensity (heat release) and duration

• increased fire growth rates, with reduced

time to flash over for unprotected CLT

compartment tests

• extended fire duration, delay of decay and

“second flash over” if delamination of layers

occurred

UK

(2014)

BBC (2015) Fire in a university

building site

✔ • large timber frame building unprotected,

under construction

Literature

review

(Multi-

Contries)

Brandon and Östman,

(2016)

Summary of several full

scale fire tests of

compartment fires

✔ ✔ • opening, fire source and types of interior

linings

7

Page 13: Book of abstracts of COST FP 1404 MC and WG meeting Action FP1404 Fire Safe Use of Bio-Based Building Products Book of abstracts of COST FP 1404 MC and WG meeting: ”Dissemination,

8

References

BBC: (2015), “University of Nottingham laboratory fire caused by electrical fault, says report”

http://www.bbc.com/news/uk-england-nottinghamshire-30751431

Brandon D., Östman B.: (2016), “Fire Safety Challenges of Tall Wood Buildings – Phase 2: Task 1 - Literature

Review - The contribution of CLT to compartment fires”, Report number: FRPF-2016-22 of the Fire

Protection Research Foundation, USA

Bregulla J., Mackay S., Matthews S.: (2010), “Fire safety on timber frame sites during construction”, 11th

World Conference on Timber Engineering (WCTE), Riva del Garda, Italy

Bullock M, Lennon T, Enjily V.: “TF2000 Stair Fire Test Summary Report”, University Manchester

http://www.mace.manchester.ac.uk/project/research/structures/strucfire /CaseStudy/Timber/stair.htm

Bullock M, Lennon T, Enjily V.: “The Fire Resistance of Medium-Rise Timber Frame Buildings Summary

Report”, University Manchester

http://www.mace.manchester.ac.uk/project/research/structures/strucfire /CaseStudy/Timber/default.htm

Dowling V., McArthur N.A., Webb A.K., Leonard J.E., Blackmore, J.: (1999), “Large Scale Fire Tests on Three

Building Materials”, Proceedings 3rd International Conference on Fire Research and Engineering,

Chicago, 4-8 October, Society of Fire Protection Engineers, Bethesda, Maryland, USA, pp 217-227

England P., Matthew E.: (2011), “Extension of the Concession which allows timber frame construction in

class 2 buildings to include class 3 buildings”, Forest & Wood Products Australia, Melbourne, Australia

Karlsson B.: (1992), “Modeling Fire Growth on Combustible Lining Materials in Enclosures,” Department of

Fire Safety Engineering, Lund University, Sweden, Report TVBB-1009

Lennon T., Bullock M., Enjily V.: (2000), "The fire resistance of timber frame building", BRE Report No

79485-1, BRE, UK.

Li X., Zhang X., Hadjisophocleus G., McGregor C.: (2014) “Experimental study of combustible and non-

combustible construction in a natural fire”, Fire Technology, 2014

Fire service Salzburg: (2010), “report of fire incident in wooden residential building Stabauergasse Salzburg”

http://www.ffb122.at/wordpress/news/einsatz/brand-eines-wohnhauses-in-der-stabauergasse/

Frangi A., & Fontana M.: (2005), “Fire Performance of Timber Structures under Natural Fire Conditions”, Fire

Safety Science Symposium 8: 279-290. IAFSS, Beijing, China.

Frangi A., Bochicchio G., Ceccotti A. & Lauriola M.P.: (2008), “Natural Full-Scale Fire Test on a 3 Storey XLam

Timber Building”, World Conference on Timber Engineering (WCTE), Miyazaki, Japan

Hakkarainen T.: (2002), “Post-flashover fire in light and heavy timber construction compartments”, Journal

of Fire Sciences, 20 (2002): 133-175.

Hasemi Y., Noboru Y., Itagaki N., Izumi J., Osaka T., Kaku T., Naruse T., Hagiwara I., Kagiya K., Suzuki J. &

Kato K.: (2014), Full-scale fire tests of 3-storey wooden school building, World Conference on Timber

Engineering (WCTE), Quebec, Canada

Hegemann K.: (2004), "Raumbrandversuche mit unterschiedlicher Belegung der Oberflächen“, MFPA Leipzig

(internal confidential report)

Kagiya K., Hasemi Y., Nam D., Hokugo A., Masuda H., Harada T., Miyatake A. & Hiramatsu Y.: (2002),

Investigation of a Large Wooden Gymnasium Fire - Its documentation, estimation of the fire scenario

by experiments and evaluation of the structural properties of surviving timber elements, Proceedings

of 7th International Symposium on Fire Safety Science

Page 14: Book of abstracts of COST FP 1404 MC and WG meeting Action FP1404 Fire Safe Use of Bio-Based Building Products Book of abstracts of COST FP 1404 MC and WG meeting: ”Dissemination,

9

Maag T., & Fontana M.: (2000), “Brandversuche an Modulhotels in Holzbauweise“, ETH Zürich, Institut für

Baustatik und Konstruktion

McGregor C.J.: (2013) “Contribution of cross-laminated timber panels to room fires”. Master thesis at

Department of Civil and Environmental Engineering Carleton University - Ottawa-Carleton Institute of

Civil and Environmental Engineering, Ottawa, Ontario, Canada

Naruse T., Kagiya K., Suzuki J., Yasui N. & Hasemi Y., (2015), Experimental Study of Time to Onset of

Flashover in Classroom Size Compartment, Proceedings of Asia-Oceania Symposium of Fire Science and

Technology (AOSFST), Tsukuba, Japan

Östman B. & Stehn L., (2014) Brand i flerbostadshus - Analys, rekommendationer och FoU-behov (Fires in

Residential Timber Buildings - Analysis, Recommendations and R&D Needs), SP Rapport 2014:07, ISSN

0284-5172, SP Technical Research Institute of Sweden

Sherlock T., Kane L.: (2011), VANCOUVER SUN

http://www.megabuilding.com/pdf/richmond-fire2.pdf

Suzuki J., Naruse T., Kagiya K., Kaku C., Yasui N., Itagaki N., Izumi J., Seki M., Kaku T. & Hasemi Y.: (2016),

Charring Behavior of Structural Timber Elements in Full Scale Fire Tests of 3 Storey Timber School

Buidling, Proceedings of World Conference on Timber Engineering (WCTE), Vienna, Austria

Schneider U., Oswald M.: (2007) „Brandschutztechnische Studie Aufbereitung des Colindale Fire“, Institut

für Hochbau und Technologie Zentrum für Baustoffforschung, Werkstofftechnik und Brandschutz, TU

Wien

Tewarson A.: (2002), “Generation of Heat and Chemical Compounds in Fires “, in SFPE Handbook of Fire

Protection Engineering, 3rd edition, Section three, Chapter 4, National Fire Protection Association,

Massachusetts, USA

Wade C.A.: (2001), “Building Fire Safety and Hazard Assessment Methods for Combustible Surface

Finishes”, Conference Paper No. 85 at the CIB World Building Congress, Building research Association

of New Zealand (BRANZ), Wellington

Watanabe M., Hasemi Y. & Yasui N., (2015), Effects of Interior Finish Designing for Fire Safety to Fires and

Behavior of Ejected Flames in School Buildings, Proceedings of Asia-Oceania Symposium of Fire Science

and Technology (AOSFST), Tsukuba, Japan

Winter, S.; Stein, R.: (2009); Abschlussbericht zum Teilprojekt 11 „Mechanismen der Brandweiterleitung bei

Gebäuden in Holzbauweise - Erstellung eines Konstruktionskataloges für Holzhäuser mit erhöhter

Brandsicherheit“ des Forschungsverbundes "Holzbau der Zukunft" im Rahmen der Hightech-Initiative

Bayern vom Bayrischen Staatsministerium für Wissenschaft, Forschung und Kunst

Page 15: Book of abstracts of COST FP 1404 MC and WG meeting Action FP1404 Fire Safe Use of Bio-Based Building Products Book of abstracts of COST FP 1404 MC and WG meeting: ”Dissemination,

10

Update on recent activities in WG1 – TG1: “Reaction to fire

performance and input parameters for simulation purposes”

Dionysios I. Kolaitis1

1School of Mechanical Engineering, National Technical University of Athens, Greece

e-mail: [email protected]

Keywords: bio-based, material properties, temperature dependence, fire testing

A short presentation of the scope of “WG1 – TG1: Reaction to fire performance and input

parameters for simulation purposes”, as well as the current and future research activities

performed in the frame of WG1 – TG1 is given below.

1. Aim of WG1-TG1 “Reaction to fire performance and input parameters for simulation

purposes”

It is well established that the thermal and structural behaviour of a bio-based construction

material exposed to fire is significantly affected by the values of its material properties, which are

commonly varied with increasing temperature. For instance, the thermal behaviour of a material

exposed to a high temperature environment is practically determined by three main physical

parameters, namely heat conductivity (c.f. Figure 1), density and specific heat capacity. On the

other hand, the mechanical behaviour of a load-bearing timber element in a case of fire is

significantly affected by the way its main mechanical properties (tensile strength, compressive

strength, shear strength, modulus of elasticity) are varied with temperature (c.f. Figure 2).

Figure 1. Temperature-thermal conductivity

relationship for wood and the char layer [1].

Figure 2. Reduction factor for strength parallel to

grain of softwood [1].

Page 16: Book of abstracts of COST FP 1404 MC and WG meeting Action FP1404 Fire Safe Use of Bio-Based Building Products Book of abstracts of COST FP 1404 MC and WG meeting: ”Dissemination,

11

A distinctive feature of bio-based construction materials is that they are essentially combustible

materials. Therefore, when exposed to a high temperature environment, a range of physical

phenomena, such as pyrolysis, charring and combustion, may occur. The rate of these phenomena

is determined by the values of relevant material properties and the manner in which they vary

with temperature. For instance, the charring behaviour of timber can be affected by a range of

physical parameters, the most important of which are density, moisture content and

permeability.

In order to perform accurate numerical simulations of the thermal and structural behaviour of

bio-based materials exposed to fire, a comprehensive knowledge of the manner in which the

aforementioned material properties vary with temperature is required. However, there are scarce

relevant reports in the open literature; also, the reported property values show considerable

scatter. As a result, the thermo-mechanical behaviour of bio-based construction materials

exposed to fire is still an active research area, focusing not only on the effects of temperature-

dependent material properties, but also on the impact of additional phenomena, such as fall off

of the protective layer (e.g. insulation board or char layer), CLT delamination, crack and fissure

formation.

Motivated by the aforementioned observations, the main aim of WG1 – TG1 is to develop a

systematic approach in determining a range of important physical properties of bio-based

construction materials, which are essential for accurate numerical simulations. Towards this end,

a variety of research activities is concurrently pursued; these activities fall into two main

categories: (a) development of an extensive database of temperature-dependent physical

properties relevant to the fire behaviour of bio-based construction materials and (b)

establishment of good practices and protocols for testing of bio-based construction materials.

WG1-TG1 is led by Davood Zeinali (University of Ghent, Belgium); the co-leader is Dionysios

Kolaitis (National Technical University of Athens, Greece).

2. Recent Activities

In the frame of establishing the fire behaviour of bio-based construction materials, an online

survey has been developed and sent out to the COST action members, aiming to collect

quantitative information on the thermal and structural behaviour of such materials, when

exposed to a fire environment. The aim of the survey is to develop a database, where the

temperature-dependent physical properties (e.g. thermal, mechanical) of bio-based construction

materials will be stored in a systematic and easy to retrieve fashion. Access to the database is

currently limited to researchers that have responded to the survey; in the future, the complete

database will be available online. So far, a limited amount of data has been collected; increased

awareness on the survey is believed to encourage an increased number of submissions.

In addition, aiming to determine best available practices for fire testing of bio-based construction

materials, there is a continuous effort to methodically collect relevant information from active

testing and research laboratories across Europe. This effort focuses on the systematic

Page 17: Book of abstracts of COST FP 1404 MC and WG meeting Action FP1404 Fire Safe Use of Bio-Based Building Products Book of abstracts of COST FP 1404 MC and WG meeting: ”Dissemination,

12

organization of quality test practices, exhibiting well-instrumented measurements and suitable

material properties characterization.

A number of papers, relevant to the scope of WG1 – TG1 has already been presented in the

Working Group Meeting of COST Action FP1404 (Barcelona, April 2015), as well as in the 1st

European Workshop of Fire Safety of Green Buildings (Berlin, October 2015).

3. Future Work

Collection of material properties and fire test results is planned to be continued until the end of

the COST action. The contents of the continuously growing database will be organized and

systematically categorized; potential trends for bench-scale (e.g. FPA and Cone Calorimeter tests)

and large-scale (e.g. SBI and Room Corner tests) fire tests of new and existing bio-based

construction materials will be thoroughly explored, by means of extensive comparative and

statistical analyses. In addition, efforts will be made to further disseminate the survey in a wider

audience. It is envisaged to create a webpage to present, in an easy to access manner, the

database of fire properties. The webpage will be actively promoted and a permanent call for more

data from interested individuals will be set up. The “final form” of the database will be presented

in a journal paper, emphasizing on the characteristics of the tests from different scales and how

they relate to each other when considered for bio-based construction materials.

Examples of good fire testing practices are continuously gathered and organized in a systematic

way. Results of this effort will be published in the form of a “technical guide”, focusing on the

important aspects of material characterization and quality measurements in tests relevant to fire

conditions. The technical guide will also include characteristic showcases of good testing

practices. The guide will be actively disseminated in a wide audience, broader than the current

COST action members. A meeting with WG1-TG1 members is planned, aiming to discuss current

testing practices and ways to enhance the characterization of sample materials in the tests;

further submissions to the fire properties database will be also discussed and encouraged.

Naturally, there is a continuous effort to identify and propose further research topics relevant to

the main scope of WG1 – TG1.

Acknowledgments

The assistance of Davood Zeinali, leader of WG1-TG1, is gratefully acknowledged.

References

[1] EN 1995-1-2, 2004. Eurocode 5: Design of timber structures - Part 1-2: General - Structural fire design.

European Committee for Standardization (CEN), Brussels, Belgium.

Page 18: Book of abstracts of COST FP 1404 MC and WG meeting Action FP1404 Fire Safe Use of Bio-Based Building Products Book of abstracts of COST FP 1404 MC and WG meeting: ”Dissemination,

13

Can we predict the charring rate? Opportunities and

Challenges in Computational Pyrolysis of Timber

Franz Richter1, Guillermo Rein2*

1 Department of Mechanical Engineering, Imperial College London, SW7 2AZ London

2 Department of Mechanical Engineering, Imperial College London, SW7 2AZ London,

[email protected]

Keywords: Timber, Charring, Complexity, Uncertainty, Eurocode

The fire behaviour of timber is controlled by charring. The heat of a fire causes the timber to

break down (charring) into insulating char and flammable volatiles, absorbing heat in the process

[1]. The volatiles diffuse to the surface, where they ignite and release heat. This heat causes the

char layer to propagate into the timber until an equilibrium, between heat release and

absorption, is reached. Thin beams burn quickly through, but in thick beams a layer of intact

timber below the char is retained. If the intact timber still holds the structure after a fire, the

structure is deemed safe.

Charring is a complex process as it involves: pyrolysis, oxidation, cracking, and multiphase heat

transfer. To model all process involved would create a model so complex, it would be impossible

to solve. Current models in the Eurocode are, therefore, simple empirical expression like the

constant charring rate [2]. These correlation were derived in furnace under a standard fire

exposure [3], making the results unusable for other heating conditions [4, 5]. Lately, there has

been an increasing trend towards a more performance-based approach in structural engineering

by using more realistic fire curves. An example of such curves are parametric and travelling fires

[6]. We require new models to predict the charring behaviour under realistic fires.

In this presentation, we will argue that the appropriate model for predicting the charring

behaviour of wood under realistic fires is of higher complexity than current models for the

standard fire [5]. Through examples we will explain why current models are too simplistic, while

showing that, at the same time, increasing complexity has to carefully evaluate. As complexity

without or weak experimental foundation—such as in-depth temperatures and mass loss rates [7,

8]—can lead to worse rather than better predictions [9] We will illustrate the last effect through

examples of model uncertainty against parameter uncertainty, and the compensation effect.

Consequently, we outline why we believe that the appropriate level of complex can only be

achieved when experimentalist and modellers work together. This COST action provides the

perfect platform to start the collaboration between experimentalist and modellers. Throughout

the talk we will highlight the importance of work from this working group.

So, can we predict the charring rate? For a few cases the answer is yes [5], but for realistic fire

exposures this question remains open.

Page 19: Book of abstracts of COST FP 1404 MC and WG meeting Action FP1404 Fire Safe Use of Bio-Based Building Products Book of abstracts of COST FP 1404 MC and WG meeting: ”Dissemination,

14

References

[1] A. Atreya, “Pyrolysis, Ignition and Fire Spread on Horizontal Surfaces of Wood,” Harvard University,

1983.

[2] EC5, “Eurocode 5: Design of Timber Structures. ENV 1995-1-2: General Rules-Structural Fire Design,”

European Committee for Standardization, Brussels, Belgium, 1994.

[3] J. Schmid, A. Santomaso, D. Brandon, U. Wickström, and A. Frangi, “Timber Under Real Fire Conditions

– the Influence of Oxygen Content and Gas Velocity on the Charring Behavior,” in World Conference on

Timber Engineering, 2016.

[4] A. I. Bartlett, R. M. Hadden, L. A. Bisby, and A. Law, “Analysis of cross-laminated timber upon exposure

to non-standard heating conditions,” in 14th International Conference and Exhibition on Fire and

Materials, 2015.

[5] K. L. Friquin, “Charring rates of heavy timber structures for Fire Safety Design,” Norwegian University

of Science and Technology, 2010.

[6] E. Rackauskaite, C. Hamel, A. Law, and G. Rein, “Improved formulation of travelling fires and

application to concrete and steel structures.” Structures, 2015.

[7] P. Reszka, “In-Depth Temperature Profiles in Pyrolyzing Wood,” University of Edinburgh, 2008.

[8] M. J. Spearpoint, “Predicting the Ignition and Burning Rate of Wood in the Cone Calorimeter Using an

Integral Model,” National Institute of Standards and Technology, 1999.

[9] N. Bal and G. Rein, “Relevant model complexity for non-charring polymer pyrolysis,” Fire Saf. J., vol. 61,

no. 0, pp. 36–44, Oct. 2013.

Page 20: Book of abstracts of COST FP 1404 MC and WG meeting Action FP1404 Fire Safe Use of Bio-Based Building Products Book of abstracts of COST FP 1404 MC and WG meeting: ”Dissemination,

15

Fundamental properties of bio-based materials for state-of-

the-art modeling of reaction to fire performance

Davood Zeinali1

1 Dept. of Flow, Heat and Combustion Mechanics, Ghent University, Belgium,

[email protected]

Keywords: bio-based, material properties, fire modeling, testing

An essential aspect of fire experiments is characterization of sample materials. Experimental data

can only be useful for future modeling of reaction to fire performance if the sample material is

well characterized with its fundamental properties. Nevertheless, despite the large number of fire

experiments conducted and cited in the literature, little data is available regarding the

fundamental properties of the used materials. This is whilst today these material properties

constitute key inputs to the contemporary fire modeling codes performing complex CFD and

pyrolysis computations [1, 2]. In the case of a corner fire [3], for instance, often no data is

available regarding the reaction kinetic parameters, surface radiative properties or the heat of

pyrolysis of the used sample materials [4-6]. As a result, simulation studies of corner fires face the

alternative of adopting these parameters from other studies or approximating them

independently [7-9]. In light of this fact, considering the great cost of most large-scale fire

experiments, there is a great need for a global call to more scientifically elaborate fire testing. In

addition, there is a need to bring together the scattered information that is available surrounding

the fire performance of bio-based products, in a way that is useful for all experts in the field of fire

safety.

In order to make reliable predictions of reaction to fire performance or fire development, a fire

modeling code requires comprehensive validation [10]. This necessitates a balanced assessment

of condensed-phase pyrolysis, gas phase kinetics, flame heat transfer and turbulent buoyant fluid

flow via comparisons with experimental measurements. Several main quantities can be

highlighted, namely, Heat Release Rate (HRR), gas temperatures (e.g. in the smoke layer), surface

temperatures (mainly in the flames area), heat fluxes, spread of flames (front, height and length),

time to flashover in the large scale, and the velocity or pressure of gases, each at a variety of

locations with respect to the fire source. Other measurements may have to be made of char

depth or its pattern on the surfaces [7], instantaneous flow stream lines [11], and the density and

composition of smoke [12].

Bearing in mind the practical value of experimental data for validation of fire models, another

crucial aspect of the experiments to consider is establishing the boundary conditions.

Measurements, among others, may have to be made of the development of pyrolysis within and

over the combustible material [11], the yield of soot and the production of smoke [12, 13], the

Page 21: Book of abstracts of COST FP 1404 MC and WG meeting Action FP1404 Fire Safe Use of Bio-Based Building Products Book of abstracts of COST FP 1404 MC and WG meeting: ”Dissemination,

16

distributions of heat fluxes [14], the visual spread of flames [15], and the flowrate patterns of

gases [16].

References

[1] FireFOAM Fire Modeling Code, Available at https://github.com/fireFoam-dev.

[2] McGrattan, K., Hostikka, S., McDermott, R., Floyd, J., Weinschenk, C., Overholt, K., Fire Dynamics

Simulator User's Guide (Sixth Edition), FDS Version 6.5.1, National Institute of Standards and

Technology (NIST), 2016, pp. 288.

[3] Zeinali, D., Agarwal, G., Gupta, A., Maragkos, G., Ren, N., Chaos, M., Wang, Y., Beji, T., Degroote, J.,

Merci, B., Computational Analysis of Pyrolysis and Flame Spread for MDF Panels Placed in a Corner

Configuration, the 8th International Seminar on Fire and Explosion Hazards, Hefei, China, 2016:

University of Science and Technology of China.

[4] Ohlemiller, T.J., Shields, J.R. (1999) The effect of surface coatings on fire growth over composite

materials in a corner configuration, Fire Safety Journal 32:173-193.

[5] Mangs, J., Mikkola, E., Kokkala, M., Soderbom, J., Stenhaug, E., Ostrup, I., Room Corner Test Round

Robin: Project 2 of the EUREFIC Fire Research Programme, VTT Technical Research Centre of Finland,

Espoo, Finland, 1991, pp. 36.

[6] Kokkala, M., Goransson, U., Soderbom, J., Five Large-Scale Room Fire Experiments–Project 3 of the

EUREFIC Fire, VTT Technical Research Centre of Finland, Espoo, Finland, 1992, pp.

[7] Yan, Z., Holmstedt, G. (1996) CFD and experimental studies of room fire growth on wall lining materials,

Fire Safety Journal 27:201-238.

[8] Hietaniemi, J., Hostikka, S., Vaari, J., FDS Simulation of Fire Spread Comparison of Model Results with

Experimental Data, VTT Building and Transport, Espoo, Finland, 2004, pp. 54.

[9] Lewis, M.J., Rubini, P.A., Moss, J.B. (2000) Field Modelling Of Non-charring Flame Spread, Fire Safety

Science 6:683-694.

[10] Wong, W.C.-K., Dembsey, N.A., Alston, J., Lautenberger, C. (2013) A multi-component dataset

framework for validation of CFD flame spread models, Journal of Fire Protection Engineering 23:85-

134.

[11] Qian, C., Turbulent Flame Spread on Vertical Corner Walls, Department of Mechanical Engineering,

University of Kentucky, Kentucky, US, 1995, pp. 161.

[12] Fang, J.B., Fire Buildup in a Room and the Role of Interior Finish Materials, National Bureau of

Standards, Center for Fire Research, Washington, DC, 1975, pp.

[13] Lattimer, B., Hunt, S.P., Wright, M., Beyler, C.L. (2003) Corner Fire Growth in a Room With a

Combustible Lining, Fire Safety Science 7:419-430.

[14] Zhang, J., Delichatsios, M., Colobert, M. (2010) Assessment of Fire Dynamics Simulator for Heat Flux

and Flame Heights Predictions from Fires in SBI Tests, Fire Technol 46:291-306.

[15] Lattimer, B.Y., Hunt, S.P., Wright, M., Sorathia, U. (2003) Modeling fire growth in a combustible corner,

Fire Safety Journal 38:771-796.

[16] Kerrison, L., Galea, E.R., Hoffmann, N., Patel, M.K. (1994) A comparison of a FLOW3D based fire field

model with experimental room fire data, Fire Safety Journal 23:387-411.

Page 22: Book of abstracts of COST FP 1404 MC and WG meeting Action FP1404 Fire Safe Use of Bio-Based Building Products Book of abstracts of COST FP 1404 MC and WG meeting: ”Dissemination,

17

The Influence of Different Fundamental Material Properties

on the Pyrolysis of Medium Density Fiberboard – A

Sensitivity Analysis by FDS

G. Zhao1, T. Beji1, D. Zeinali1, B. Merci1

1 Dept. of Flow, Heat and Combustion Mechanics, Ghent University, Belgium,

[email protected]

Keywords: Timber, Charring, Complexity, Uncertainty, Eurocode

In this paper we present numerical simulations of Medium Density Fiberboard (MDF) pyrolysis

using a one-dimensional heat transfer solver that includes in-depth radiation transport [1]. The

results are compared with the results of several small scale tests conducted in the Fire

Propagation Apparatus (FPA) [2], where nitrogen atmosphere has been used in order to eliminate

uncertainties related to gas phase combustion. During the FPA tests, the mass loss rate, surface

and back side temperatures have been measured under three constant external heat fluxes (25,

50, 100 kW/m2) in the set-up show in Fig. 1. More details can be found in reference [2].

Figure 1. Schematic of the MDF sample in the FPA Test.

The influence of the material properties and model parameters on the pyrolysis behaviour of MDF

has been investigated in detail through a sensitivity analysis using Fire Dynamics Simulator (FDS,

version 6.2.0). A one-step finite rate reaction is assumed; the virgin material is converted to char

and the rest is released as pyrolysate. The values of the kinetic parameters and char yield are

estimated based on Thermogravimetric Analysis (TGA) test results reported in [3]. It is assumed

no shrinkage and swelling occur during the whole process.

The base simulation case considered does not show satisfactory results for the time to reach the

first peak and the value of that peak in the mass loss rate curve when compared to experimental

data. The predicted time to peak and the value of that peak are significantly lower than the

measured value, namely by about 62 to 50% for heat flux 50 kW/m2.

In order to improve the predictions of the onset of pyrolysis and the value of the peak MLR, the

influence of thermal conductivity, specific heat, heat of pyrolysis, and the moisture content was

Page 23: Book of abstracts of COST FP 1404 MC and WG meeting Action FP1404 Fire Safe Use of Bio-Based Building Products Book of abstracts of COST FP 1404 MC and WG meeting: ”Dissemination,

18

studied. However, changes in none of these parameters showed satisfactory results for the time

to reach the peak value of the burning rate when compared to experimental data. Subsequently,

we investigated the effect of the emissivity, through-thickness density profile, and in-depth

radiation through the sensitivity analysis.

In the considered parameter ranges, the most significant influence on the time to the first peak

comes from the emissivity, followed by the thermal conductivity, specific heat, and moisture

content. For the peak mass loss rate, the most significant influence comes from the absorption

coefficient, followed by the through-thickness density, then the moisture content, and the specific

heat.

Through a simple trial and error procedure, a set of ‘optimized’ parameter values has been

obtained. For the absorption coefficient, we assumed that the material is opaque until it starts

charring, then values of 50000 m-1 and 2000 m-1 have been determined for the absorption

coefficient of virgin and char, respectively. During this optimization procedure, the parameters

showing significant influence have been considered, which results in better agreement with

experimental data (Fig. 2).

(a) (b)

Figure 2. Comparisons between experiment and simulation using optimized parameter values (a) mass loss rate, (b) surface temperature.

Acknowledgements

The authors would like to thank the China Scholar-ship Council (CSC) for the financial support for

the first author. Dr. Tarek Beji is a Postdoctoral Fellow of the Fund for Scientific Research-Flanders

(Belgium).

References

[1] McGrattan, K., Randall McDermott, etc. Fire dynamics simulator User’s Guide, National Institute of

Standards and Technology Report NIST special publication 1019. (2016).

[2] Agarwal, G., Chaos, M, Wang, Y. Zeinali, D., and Merci, B., Pyrolysis Model Properties of Engineered

Wood Products and Validation Using Transient Heating Scenarios, Interflam 2016, 14th International

Conference and Exhibition on Fire Science and Engineering, Royal Holloway College, UK, 2016.

[3] Kaiyuan, Li., etc. Pyrolysis of Medium-Density Fiberboard: optimized search for Kinetics scheme and

parameters via a genetic algorithm driven by Kissinger’s method. Energy &Fuels. (2014).

Page 24: Book of abstracts of COST FP 1404 MC and WG meeting Action FP1404 Fire Safe Use of Bio-Based Building Products Book of abstracts of COST FP 1404 MC and WG meeting: ”Dissemination,

19

Working Group 2

Structural Elements made of bio-based building materials

and detailing

Page 25: Book of abstracts of COST FP 1404 MC and WG meeting Action FP1404 Fire Safe Use of Bio-Based Building Products Book of abstracts of COST FP 1404 MC and WG meeting: ”Dissemination,

20

Review and Determination of Fire Resistance Ratings for

Glulam Connectors

David Barber1

1 1120 Connecticut Avenue, Washington DC, Arup, US, [email protected]

Keywords: fire safety, connections, mass timber buildings, fire testing

Introduction

Engineered timbers such as glulam and cross-laminated timber (CLT) are being utilised for multi-

storey buildings. A challenge faced by both medium and high-rise buildings is the fire safe and

efficient design of connections in both CLT and glulam. Connections within CLT panels have been

mostly proven through manufacturer fire testing. Where glulam members are used as part of the

structural frame, the column to beam and beam to beam connections need to be constructed

with a fire resistance rating (FRR) equal to that of the connecting members, typically exceeding 60

minutes. Building construction is limited by the few applicable methodologies to assess

connection capacity under fire when the timber is exposed and not clad behind fire protective

plasterboard.

Background

To achieve an FRR within a glulam beam to column connection there are three approaches:

1. Encapsulate the connection within fire rated gypsum that provides the required FRR.

2. The connector is partly concealed by the timber, with bolts or dowels exposed only.

3. The connector is fully concealed by the timber, so that no part of the connector is

exposed.

Encapsulated connectors are addressed by proprietary tested and approved wall and ceiling

plasterboard systems. Where a connector will be concealed within exposed timber, the preferred

glulam connector is either a steel knife-plate with bolts / dowels; or a proprietary screw-in sleeve

type connector. Concealed connectors use the timber to provide the appropriate insulation to

protect them from fire. These types of connectors are difficult and expensive to design and

construct as strong elements.

From a review of existing literature on fire testing of glulam connectors, the following key points

are summarised:

• There are numerous fire or elevated temperature tests are on simple tension connectors,

which have limited application to real building situations, as buildings rarely utilise

members in tension.

Page 26: Book of abstracts of COST FP 1404 MC and WG meeting Action FP1404 Fire Safe Use of Bio-Based Building Products Book of abstracts of COST FP 1404 MC and WG meeting: ”Dissemination,

21

• Analytical methods available are based on tension tests and hence are not as accurate for

a real building connection that is undergoing bending and shear. There needs to be more

tests on full size, loaded shear type connectors.

• Many fire tests are undertaken on smaller members and tested to a standard time-

temperature curve, but very few tests are taken to 60 minutes or beyond.

• Achieving an FRR of 60 minutes to 120 minutes requires significant depth of timber cover

and there does not appear to be proven correlations to calculate the FRR for typical beam

to column connectors.

• The FRR of a concealed steel knife-plate is influenced by the exposed dowels or bolts.

Having no steel exposed increases the FRR and improves the temperature distribution

within the residual cross-section.

• Intumescent paint does not increase the fire resistance significantly, as the weak point of

the connection is the timber and protecting the steel does not improve this weakness.

• There is a lack of fire testing on real timber connections with real (natural) fires.

• Fully concealed sleeve or seated connections can have the best fire performance.

Why Connectors Fail

Tests on timber connections at elevated temperatures have shown a common failure mode with

deformation in the timber through embedment failure. As the timber is exposed to elevated

temperatures, it starts to lose its inherent strength (stiffness) around the connector. As the

stiffness reduces with increasing temperatures, the ability to resist the applied shear forces drops-

off. Embedment failure is first seen through increased ovalisation, with the bolts / dowels typically

remaining straight as the timber weakens around them. The ovalisation occurs both parallel and

perpendicular to the grain at the bolt or dowel, or screws securing the sleeve connector. The

mechanical properties of timber under heating are well researched, though embedment strength

is not fully determined [Erchinger, 2010; Maraveas, 2013; Palma, 2014; Audebert, 2011].

Determining a Solution

To effectively support the applied loads and transfer the forces through the connection, therefore

preventing the embedment failure, the connection components must be located within timber

that will provide adequate stiffness at the knife plate and bolts / dowels, or at the screws to the

sleeve connector, for full fire duration. Accounting for the loss of strength in the timber directly

behind the char layer and the specific depth of that weakened timber becomes critical for a

concealed steel connectors. There are significant difficulties modelling heat-transfer and

mechanical properties simultaneously as the timber properties are changing under heating. There

are a number of empirical models and FEA models that have limited application.

It is evident from the literature reviewed there is no simple method for determining an FRR past

60 minutes. Factors influencing the connection performance are:

• When there are any parts of the steel connector exposed to a fire, these will weaken the

connection through transfer of heat into the connection. Avoiding any steel components

being exposed to the fire will improve the FRR.

Page 27: Book of abstracts of COST FP 1404 MC and WG meeting Action FP1404 Fire Safe Use of Bio-Based Building Products Book of abstracts of COST FP 1404 MC and WG meeting: ”Dissemination,

22

• The connection may have an increased char rate, due to the connection components.

Where there are bolts or dowels exposed, there will be a measurable increase in charring.

Where the steel connection is fully concealed, the increased charring will be reduced. The

impact of the thermal mass of the connection can increase the char rate by 5 to 10%.

• Accounting for the loss of strength in the timber directly behind the char layer and the

specific depth of that weakened timber becomes critical for a concealed steel connectors.

The timber loses strength quickly, with the strength parallel to the grain about 60%

(compression) to 80% (tension) of its ambient value, once the timber reaches 75°C.

• By designing a connection that is within timber that retains strength and stiffness, the

significant loss of strength of the timber at elevated temperatures can be minimized or

avoided.

The basis of the connection design undertaken has been that timber cover will provide adequate

insulation to the fire exposure such that the connector components are within timber that retains

50% of its embedment strength. Also, by designing to a pre-determined embedment value, the

influence of load-ratio and the reducing strength of the timber under heat is accounted for.

To determine where the embedment strength will reduce below a critical value, requires an

understanding of the temperature profile within the timber, behind the char layer. The “thermal

penetration depth” is estimated as ranging from 25mm to 50mm behind the char layer, increasing

as the fire duration increases [Frangi, 2003; Friquin, 2010; Konig, 1999; Schmid, 2014].

The value of 50% embedment strength can be attributed to a timber temperature of 100oC. Based

on the empirical results, a depth of 15mm to 20mm behind the char layer will maintain a timber

temperature of 100°C. The other factor to account for is the increased char rate at the

connection, which is increased by 5%.

Methodology Fire Testing

Fire testing has been carried out on full-size glulam beam-column connections that are loaded to

replicate actual building conditions, to determine an FRR. The connection design is based on a

fully concealed steel angle plate that supports the beam in bearing (see Figure 1). The steel angle-

plate was designed specifically for the project and can be installed efficiently during construction.

The weak point of the connection is the beam base, where a solid timber block is required to fill a

pre-cut cavity in the beam, to allow the connection to be installed.

The glulam beam side and base cover to the steel connection was designed to the methodology

described above, taking into account timber stiffness related to thermal penetration depth behind

the char layer and increased char rate.

The beam-column connection was fire tested using a mid-size furnace of 1.8m x 1.5m square with

a furnace depth of approximately 2m. Each beam-column connection was exposed to the ASTM

E119 standard time-temperature curve, up to 120 minutes. The member sizes tested ranged in

beam width and type of glulam, with five full size specimens tested. The applied loading,

representative of an office floor, was provided through a test specific loading frame.

Temperatures were recorded at the connection, as were deflections of the beam. Of the five

Page 28: Book of abstracts of COST FP 1404 MC and WG meeting Action FP1404 Fire Safe Use of Bio-Based Building Products Book of abstracts of COST FP 1404 MC and WG meeting: ”Dissemination,

23

tests, two achieved an FRR of 120 minutes. Deflections of up to 20mm were measured at the

connection.

Figure 1 – Rendering of beam column connection tested to achieve 120 mins FRR

References

[1] Audebert, M., Dhima D., Taazount, M., Bouchaïr, A., 2011, “Numerical Investigations on the Thermo-

Mechanical Behavior of Steel to Timber Joints Exposed To Fire” Engineering Structures 33, 3257-3268

[2] Erchinger, C., Frangi, A., Fontana, M., 2010, “Fire Design of Steel-to-Timber Dowelled Connections”,

Engineering Structures 32, pp580-589

[3] Frangi, A., Fontana, M., 2003; “Charring Rates and Temperature Profiles of Wood Sections”, Fire and

Materials, 27: 91–102

[4] Friquin, K.L., 2010 “Charring Rates of Heavy Timber Structures for Fire Safety Design: A Study of the

Charring Rates under Various Fire Exposures and the Influencing Factors” Doctoral theses at NTNU,

2010:128, Norwegian University of Science and Technology

[5] König, J. and Walleij, L., 1999, “One-dimensional charring of timber exposed to standard and

Parametric fires in initially unprotected and post-protection situations”. Swedish Institute for Wood

Technology Research. Report I 9908029, Stockholm

[6] Maraveas, C., Miamis, K., Mathew, C., 2013, “Performance of Timber Connections Exposed to Fire: A

Review”, Fire Technology, Published online November, 2013

[7] Palma, P., Frangi, A., Hugi E., Cachim, P., Cruz, H., 2014, “Fire Resistance tests on beam-column shear

connections” 8th International Conference on Structures in Fire, Shanghai, China, June 11-13

[10] Schmid, J., Just, A., Klippel, M., Fragiacomo, M., 2014, “The Reduced Cross-Section Method for

Evaluation of the Fire Resistance of Timber Members: Discussion and Determination of the Zero-

Strength Layer” Fire Technology, published online 15 July 2014

Page 29: Book of abstracts of COST FP 1404 MC and WG meeting Action FP1404 Fire Safe Use of Bio-Based Building Products Book of abstracts of COST FP 1404 MC and WG meeting: ”Dissemination,

24

Fire part of Eurocode 5 EN 1995-1-2 - revision status and

perspective

Andrea Frangi1

1 Institute of Structural Engineering, ETH Zurich, Switzerland [email protected]

Keywords: Eurocode 5, Fire part, EN 1995-1-2

Introduction

The European standards Eurocodes provide common design rules for the design of structures with

all main building materials creating the built environment. The European Committee for

Standardization (CEN, Comité Européen de Normalisation) is responsible for developing and

defining standards at European level and it is officially recognised by the European Union and the

European Free Trade Association (EFTA). The technical committee (TC) working on the

development and definition of the design rules of common building and civil engineering

structures has been numbered as CEN/TC 250 and has currently 11 subcommittees (SC). CEN/TC

250/SC5 is responsible for the European standard Eurocode 5, which deals with the design of

timber structures and it consists of 3 parts: Part 1-1: General - Common rules and rules for

buildings; Part 1-2: General - Structural fire design; Part 2: Bridges. All parts were published in

2004 after a long historical development starting in 1983 with a CIB report “Structural Timber

Design Code” [6].

The European Commission has a strong interest on the further development of the Eurocodes to

achieve a further harmonisation of design rules in Europe and the revision process of all

Eurocodes has recently started. The second generation of the Eurocodes is expected to be

published starting from 2020. The main objectives of the revision are the improvement of the

Ease-of-Use of the Eurocodes for practical users, the reduction of National Determined

Parameters and the further harmonisation and inclusion of state-of-the-art. After an intensive

discussion within CEN/TC 250 it was defined that the Eurocodes are addressed to competent civil,

structural and geotechnical engineers, typically qualified professionals able to work independently

in relevant fields [6].

Current EN 1995-1-2

The current Eurocode 5, fire part (EN 1995-1-2 [1]) was published 2004 and gives rules for the fire

design of timber structures, that are based on the state-of-the-art at the beginning of 2000.

Compared to the European pre-standard ENV 1995-1-2:1994, the EN 1995-1-2:2004 undergone

considerable changes. Within EN 1995-1-2, charring is dealt with in a more systematic way and

different stages of protection and charring rates are applied. For the determination of cross-

sectional strength and stiffness properties, two alternative rules are given, either by implicitly

taking into account their reduction due to elevated temperature by reducing the residual cross-

Page 30: Book of abstracts of COST FP 1404 MC and WG meeting Action FP1404 Fire Safe Use of Bio-Based Building Products Book of abstracts of COST FP 1404 MC and WG meeting: ”Dissemination,

25

section by a zero-strength layer, or by calculating modification factors for strength and stiffness

parameters. Design rules for charring and modification factors are also given for timber frame

members of wall and floor assemblies with cavities filled with insulation. A modified components

additive method has been included for the verification of the separating function. The design

rules for connections have been systemised by introducing simple relationships between the load-

bearing capacity (mechanical resistance) and time. The current EN 1995-1-2 provides thermal and

thermo-mechanical properties for advanced thermal and structural analysis. It also gives some

limited design rules for natural fire exposure using parametric fire curves [10].

Structure of the second generation of the Eurocodes fire part

In order to harmonise all material fire parts of the new Eurocodes a Project Team of the Horizontal

Group Fire (HGF) has been established. The HGF PT has proposed a common harmonised structure for

all material fire parts of the new Eurocodes as shown in figure 1.

Table of content of EN 199x-1-2 1 General 2 Basis of design

3 Material properties

4 Tabulated design data

5 Simplified design methods

6 Advanced design methods 7 Detailing

Figure 1. Common harmonised table of content for all material fire parts of the new Eurocodes as proposed

by the Project Team of the Horizontal Group Fire (HGF) of TC250

The verification of the mechanical resistance for the required duration of fire exposure can be

performed using tabulated design data for specific types of members, simplified design methods for

specific types of members or advanced design methods for the analysis of members, parts of the

structure or the entire structure. Tabulated design data provide recognised design solutions generally

in relation to section typology without recourse to any form of equilibrium equation. Tabulated data

may be derived from tests, calculation models or some combination of the two and may be presented

either in the form of a table or an equation. Tabulated design data give conservative results compared

to relevant tests or simplified or advanced design methods and an extrapolation outside the range of

application is not permitted. Simplified design methods are based on global equilibrium equations and

do not necessarily require the use of complex analytical or numerical models. Advanced calculation

methods are based on fundamental physical behaviour, employing local equilibrium equations which

are satisfied at every point in the structure. Calculations are undertaken using complex numerical

models based on finite element analyses or other appropriate advanced procedures.

The current EN 1995-1-2 does not have tabulated design data. Thus, it is important that this new

opportunity is analysed in detail and the need and preparation of tabulated design data is defined in

strong collaboration with the practice and industry.

Page 31: Book of abstracts of COST FP 1404 MC and WG meeting Action FP1404 Fire Safe Use of Bio-Based Building Products Book of abstracts of COST FP 1404 MC and WG meeting: ”Dissemination,

26

Current state of work revision of EN 1995-1-2

The revision work of EN 1995-1-2 [1] is performed and coordinated by the Working Group WG4 of

CEN/TC250/SC5 chaired by the author of this paper with participants from several countries active in

the field. Further, the revision is supported by the Cost Action FP1404 and the global network Fire Safe

Use of Wood (FSUW). One fundamental objective of the current work activities of

CEN/TC250/SC5/WG4 is the preparation of an extensive background document with the update state-

of-the-art with regard to the structural fire behaviour and fire design of timber structures. The

background document will be the basis for the drafting work of the new EN 1995-1-2 by the Project

Team (PT), which will be established at the beginning of 2018.

Based on the principles set up for the revision and the results of the systematic review of the current

EN 1995-1-2, it was possible to identify the need for the improvement and extension of the fire design

rules for the second generation of EN 1995-1-2. The following list gives the most important items

considered in the revision process:

• The current charring model will be generalised and will consider different phase of protection [8,9].

The failure times (defined as fall-off times) of different protective claddings, including gypsum

plasterboard Type A and F (according to EN 520) and gypsum fibre boards (according to EN 15283-

2) will be given with simplified equations based on a large data base of fire tests [4]. Further, for the fire design there will be the possibility to use failure times based on full-scale fire tests

performed according to EN 13381-7 (Test methods for determining the contribution to the fire

resistance of structural members - Part 7: Applied protection to timber members), which has

completely been revised, is currently under formal vote and if accepted should be published this

year.

• As simplified design method only the current Reduced Cross-section Method (in the future

renamed as Effective Cross-section Method) will be given [13]. The current Reduced Properties Method will be deleted. The Effective Cross-section Method will be revised and its use will

extended to all common structural timber members [7,14]. The application of the design method

should be extended to 90 minutes fire resistance, if possible even more.

• The current annexes C (timber frame assemblies with filled cavities) and D (timber frame

assemblies with void cavities) will be improved and moved to the main part of EN 1995-1-2. The

revised content will become normative. The design model for timber frame assemblies with filled

cavities is based on the Effective Cross-section Method and will allow considering the performance of different kind of insulation (mineral wool, cellulose, wood fibre, etc.). The performance of the

insulation can be evaluated with small-scale fire tests and classified in 3 different protection level

[5,15].

• The current annexe E (Component additive method for the verification of the separating function)

will be improved and moved to the main part of the EN 1995-1-2 [2]. The revised content will

become normative.

• New rules for the fire design of cross-laminated timber panel (CLT) and timber-concrete-composite

elements (TCC) will be introduced [3,8,9]. For CLT, tabulated design data can be given as discussed

in [8].

• Improved rules for the fire design of connections will be given based on extensive experimental and numerical analysis [11,12].

• Effective thermal and mechanical properties for timber, gypsum and insulation will be given for advanced calculation models based on FE-analysis.

Page 32: Book of abstracts of COST FP 1404 MC and WG meeting Action FP1404 Fire Safe Use of Bio-Based Building Products Book of abstracts of COST FP 1404 MC and WG meeting: ”Dissemination,

27

It is expected that the second generation of EN 1995-1-2 will fill most gaps of the current EN 1995-1-2

and will allow a safe and economic design of timber structures in fire.

Acknowledgments

The author gratefully acknowledge the European COST Action FP1404 for the large support for

the revision of EN 1995-1-2.

References

[1] EN 1995-1-2 (Eurocode 5) (2010): Design of timber structures, Part 1-2: General – Structural fire

design, CEN, Brussel.

[2] Frangi A., Schleifer V., Fontana M. (2010), Design model for the verification of the separating function

of light timber frame assemblies, Engineering Structures 2010; 32: 1184–1195.

[3] Frangi A., Knobloch M., Fontana M. (2010), Fire design of timber-concrete composite slabs with

screwed connection, Journal of Structural Engineering (ASCE) 2010; 136: 219–228.

[4] Just A., Kraudok K., Schmid J., Östman B. (2015), Protection by gypsum plasterboards - state of the art,

Proceedings of the 1st European Workshop Fire Safety of Green Buildings, October 6-7, 2015, Berlin.

[5] Just A., Tiso M. (2016), Improved fire design model for timber frame assemblies, Proceedings of INTER

Meeting, August 16-19, 2016, TU Graz, Graz, Austria.

[6] Kleinhenz M., Winter S., Dietsch P. (2016), Eurocode 5 – A halftime summary of the revision process,

Proceedings of 14th World Conference on Timber Engineering (WCTE), August 22-25, 2016, Vienna,

Austria.

[7] Klippel M., Schmid J., Frangi A. (2012), The Reduced Cross-section Method for timber members

subjected to compression, tension and bending in fire, Proceedings of CIB-W18 Meeting, August 27-30,

2012, Växjö, Sweden.

[8] Klippel M., Schmid J., Frangi A. (2016), Fire Design of CLT, Proceedings of the Joint Conference of COST

Actions FP1402 and FP1404, March 10-11, 2016, Stockholm, Sweden.

[9] Klippel M., Schmid J. (2017), Design of cross-laminated timber in fire, Structural Engineering

International, Paper in Press.

[10] König J. (2005), Structural fire design according to Eurocode 5—design rules and their background, Fire

and Materials 2005; 29: 147–163.

[11] Palma P., Frangi A. (2016), A framework for finite element modelling of timber connections in fire,

Proceedings of 9th International Conference on Structures in Fire, June 8-10, 2016, Princeton

University, Princeton, USA.

[12] Palma P., Frangi A. (2016), Fire design of timber connections – assessment of current design rules and

improvement proposals, Proceedings of INTER Meeting, August 16-19, 2016, TU Graz, Graz, Austria.

[13] Schmid J., König J., Just A. (2012), The reduced cross-section method for the design of timber

structures exposed to fire-background, limitations and new developments, Structural Engineering

International 2012; 22: 514−522.

[14] Schmid J., Klippel M., Just A., Frangi A. (2014), Review and analysis of fire resistance tests of timber

members in bending, tension and compression with respect to the Reduced Cross-Section Method,

Fire Safety Journal 2014; 68: 81−99.

[15] Tiso M., Just A. (2017), Fire protection provided by insulation materials – new design approach for

timber frame assemblies, Structural Engineering International, Paper in Press.

Page 33: Book of abstracts of COST FP 1404 MC and WG meeting Action FP1404 Fire Safe Use of Bio-Based Building Products Book of abstracts of COST FP 1404 MC and WG meeting: ”Dissemination,

28

Short review of the research conducted on the fire

behaviour of timber-concrete composite systems

Tomaž Hozjan1, Anita Ogrin1, Michael Klippel2

1 University of Ljubljana, Faculty of Civil end Geodetic Engineering, Jamova 2, 1000 Ljubljana, Slovenia, [email protected] 2 Institute of Structural Engineering, ETH Zurich, Switzerland [email protected]

Keywords: TCC structures, fire, SOA, experiments, simplified models

Composite structures present very optimized and popular structural bearing systems. Usually,

composite structures are composed of two different materials in such way that each of the

material can be fully exploited, for instance timber-concrete composite systems combine the high

compressive load capacity of concrete and additionally the tension capacity, low weight and also

lower environmental impact of timber. In fire, the changes in stiffness and strength that occur in

the different components (timber, concrete, and connector) of the timber-concrete composite

structure are of special interest. Experimental work of structures exposed to fire is usually not as

extensive as in case of experimental work at room temperature. The present abstract presents a

short review of the research work of the timber-concrete composite (TCC) systems in fire

conditions carried out in recent years.

TCC beams with screwed connections and dowels were extensively investigated at ETH Zurich.

During this research, 23 full-scale tests fire tests using the standard ISO fire curve [1] and 46 small-

scale tests at elevated temperature were performed. The work is summarised in the PhD thesis of

Frangi [2]. Inclined screws were tested in small-scale fire tests with tensile and shear loading of

the connectors. The main outcome of the fire tests showed that (i) the load-carrying behaviour of

the connection with axially loaded screws depends on the temperature-dependent reduction of

withdrawal strength and stiffness of timber, and (ii) that the temperature measured around the

connection mainly depends on the timber side cover of the connection. Based on the

experimental investigations Frangi et al. [3] developed a simplified design method for the

calculation of the fire resistance of timber-concrete composite slabs using screwed connections.

The calculation method is based on the reduced cross section method given in EN 1995-1-2 [4]

and on the basis of the γ - method for mechanically jointed beams with flexible elastic connection

given in EN 1995-1-1 [5].

O'Neill [6] investigated the failure behaviour of timber-concrete composite floors exposed to

standard ISO 834 design fire [1]. Beams were made from Laminated Veneer Lumber (LVL). Two

different types of connections between concrete slab and LVL beam were used in each test

specimen. The first type of connection was a notched connection with steel screws and the

second type was a plate solution connection (i.e. toothed steel plate). Overall, two tests with

Page 34: Book of abstracts of COST FP 1404 MC and WG meeting Action FP1404 Fire Safe Use of Bio-Based Building Products Book of abstracts of COST FP 1404 MC and WG meeting: ”Dissemination,

29

different beam heights were carried out, as well as series of small-scale tests, to investigate the

failure strength and behaviour of the LVL at different temperatures (46 tests altogether). Main

conclusions from the tests were: (i) beams with steel plate connection behave stiffer than the

ones with a notched connection, (ii) the charring rate on the sides of the LVL beams was found to

be 0.58 mm/min on average, (iii) separation of the double LVL members during the latter stages

of burning was noticed, (iv) the charring rate on the underside was on average four times larger

than the charring rate from either side of the beam, (v) concrete spalling in the slab was noticed

for the lower quality concrete mix. A simplified design model was developed based on the

experimental results.

TCC floor systems were also investigated at Czech technical University. Caldova [7] reported the

results of two full-scale experimental tests and presented a validation of a 3D numerical model.

The floor specimens of size 3.5 m by 4 m were exposed to standard ISO fire [Source]. Additionally,

the test was also performed at room temperature. The composite timber-concrete floor was

composed of a timber frame, two secondary beams, and a concrete slab connected to floor joists.

Screwed connections were used between timber and concrete.

Tests on a CLT floor system, laminated and plywood assemblies connected to a concrete layer are

reported in [8]. All specimens were exposed to standard ISO fire. For the CLT floor system self-

tapping screws were used as connectors inclined at 45o, and in case of the laminated assembly

steel truss plates were used. In both cases, large fire resistances was observed (over 120 min). The

advantage of the laminated wood assembly is that the layers (plies) are continuous across their

depth and thus charring was slower than in the CLT floor assembly. The use of shear connectors

between the timber and the concrete had little or no observable impact on transferring heat into

the concrete while a minimal temperature increase at the timber-concrete interface was

observed.

The new Eurocode 5 will contain new rules for the fire design of timber-concrete-composite

elements. This task group will support the revision of Eurocode and thus CEN/TC 250/SC5/WG4.

References

[1] International Organization for Standardization (ISO). (1999). “Fire-resistance tests – Elements of building

construction – Part 1: General requirements.” ISO 834-1, Geneva, Switzerland.

[2] Frangi, A. (2001). “Brandverhalten von Holz-Beton-Verbunddecken”, PhD thesis no 14328, Institute of

Structural Engineering, ETH Zurich, Switzerland (in German).

[3] Frangi A, Knobloch M, Fontana M. (2010). “Fire Design of Timber-Concrete Composite Slabs with Screwed

Connections”, ASCE Journal of Structural Engineering, Vol. 136, No. 2.

[4] EN 1995-1-2 (Eurocode 5) (2010): Design of timber structures, Part 1-2: General – Structural fire design, CEN,

Brussels.

[5] EN 1995-1-1 (Eurocode 5) (2004): Design of timber structures, Part 1-1: General – Common rules for

buildings, CEN, Brussels.

[6] O’Neill J. W., Abu A.K., Carradine D. M., Moss P.J., Buchanan A.H. (2014). Modelling the Fire Performance of

Structural Timber-Concrete Composite Floors. Journal of Structural Fire Engineering, vol. 5, no. 2, 113–123.

[7] Caldová E., Vymlátil P., Wald F., Kuklíková A. (2015). ”Timber Steel Fiber–Reinforced Concrete Floor Slabs in

Fire: Experimental and Numerical Modeling, J. Struct. Eng., vol. 141. , No.9.

Page 35: Book of abstracts of COST FP 1404 MC and WG meeting Action FP1404 Fire Safe Use of Bio-Based Building Products Book of abstracts of COST FP 1404 MC and WG meeting: ”Dissemination,

30

[8] Osborne L. (2015). “Fire Resistance of Long Span Composite Wood-Concrete Floor Systems”, Report, pp. 1–

44.

Page 36: Book of abstracts of COST FP 1404 MC and WG meeting Action FP1404 Fire Safe Use of Bio-Based Building Products Book of abstracts of COST FP 1404 MC and WG meeting: ”Dissemination,

31

Fire safety of timber buildings under construction –

Overview of guidelines and recommendations

Yves Martin1, Michael Klippel2, Jan Gmür3, Eliott Odermatt3

1 Civil Eng., Head of the Division Roofs, Facades and Carpentry, Direction Research & Innovation,

Belgian Building Research Institute, Rue du Lombard 42, B-1000 Brussels, Belgium,

[email protected]

2 Institute of Structural Engineering, ETH Zürich, 8093 Zürich, Switzerland,

[email protected]

3 ETH Zürich, Switzerland

Keywords: fire safety, timber building, construction phase, fire incidents, guidelines

In the last few years, the construction of timber multi-storey buildings has been gaining more

importance in most European countries. Timber construction presents numerous strong points for

sustainability and there are also other pragmatic reasons why timber constructions are increasing

their market share to the detriment of heavy constructions: prefabrication, speed of assembly,

new architectural tendencies, possibility of enlarging the thermal insulation layers in the façade

without increasing the traditional thickness of the facades. New knowledge concerning the

performances of wooden constructions and materials has been developed, e.g. regarding to

acoustic quality [1] [2] and fire safety [3]. As a result, many countries have revised their fire

regulations, permitting greater use of timber. Many countries do not limit the number of storeys

in timber buildings and the traditional use of timber for low-rise (two-storeys or less) and mid-rise

(three- to five-storeys) buildings is now being extended with design for new high-rise buildings

(six-storeys or greater) [4] [5].

Numerous fire safety concepts during the usage phase of buildings were developed reaching a

very good level and allowing e.g.

• modern apartment buildings with timber frame to have a lower rate of fire incidents

compared to the entire apartment building stock [6]

• timber frame to show similar area of heat and flame damage in fires when compared to

other construction types [7]

However, during the construction phase, timber buildings could be particularly vulnerable to fire.

The main fire safety measures were developed to operate only at the final state of the building,

e.g. detection and suppression systems, compartmentation and fire-resistant protection layers.

Before the implementation of these measures, timber constructions could be unprotected and

directly exposed to e.g. hot works, a term that covers a number of work techniques producing

Page 37: Book of abstracts of COST FP 1404 MC and WG meeting Action FP1404 Fire Safe Use of Bio-Based Building Products Book of abstracts of COST FP 1404 MC and WG meeting: ”Dissemination,

32

sparks, using flames or generating strong heat. According to an analysis of fires in buildings in

England (period 2009 to 2012) [7], the area of heat and flame damage over 20 m² in fires in

timber buildings under construction is overrepresented when compared to other construction

types [7] – see Fig. 1. Out of total fires in timber framed dwellings under construction, 24% of

these resulted in damage of an area of more than 100 m2 compared to 4% for dwellings of other

types. Among buildings under construction, the ratio of fires in timber frame buildings to fires in

other type buildings is much higher at (1:9) compared to the same ratio for buildings not under

construction (1:57).

Figure 1. Distribution of heat and flame damage over 20 m2 in fires under construction. Timber framing is

overrepresented in large areas when compared to other construction types [7]

Finally, fires in timber buildings have a psychological impact on the society, taking further the

perception of an increased fire hazard.

For these reasons, it seems necessary to recommend measures to extend the fire safety of timber

buildings to the construction phase. In the technical working group WG2-TG7 of the COST Action

FP 1404, a study has been recently started to collect guidelines and to propose recommendations

for fire safety of timber buildings during the construction phase. The study is divided in two main

tasks:

• 1/ Collect information and create a database of fire incidents in timber buildings during

the construction phase.

• 2/ Compilation and comparison of guidelines, norms and laws from different countries.

Finally, the objective is to establish a state-of-the-art in matter of fire safety of timber buildings

under construction in order to propose a selection of measures and recommendations regarding

this issue.

For the development of the database about fire incidents in timber buildings under construction,

the following information has been collected: general information (country, city, month and year),

building characteristics (type of planned occupation, number of (timber) storeys, light or heavy

Page 38: Book of abstracts of COST FP 1404 MC and WG meeting Action FP1404 Fire Safe Use of Bio-Based Building Products Book of abstracts of COST FP 1404 MC and WG meeting: ”Dissemination,

33

timber framing), consequences (injuries, fatalities, direct consequences to neighbourhood,

surface of damage, ...), possible cause (hot work, arson, ...), sources and subjective quality

evaluation of the available information.

The information was collected through

• 1/ a literature review (general news articles and technical reports)

• 2/ an invitation to the members of Cost Action FP1404 to add fire accidents and/or to ask

the contribution of experts of their countries who could contribute to the research.

72 fire incidents of timber buildings under construction (66 from the literature review and at the

moment 6 from the COST-members) were gathered and investigated. Fire incidents were found in

Canada (33%), USA (32%), UK (27%), Italy (5%) and Belgium (3%).

The number of gathered incidents is not impressive (especially when compared to 118 fires of

timber buildings under construction in UK for a period a 2 years analysed by [7]). It is difficult to

collect information because only sensational fires get detailed attention and the majority of fires

are small and remains unknown or confidential. Unfortunately, the collected information are not

always exhaustive, e.g. the type of timber construction (heavy framing or light framing) is

unknown for 82% of the entries, the damage to neighbouring buildings is unknown for 71% of the

entries (12% without damage and 17 % with damage). The analysis shows that the main

(suspected) cause of ignition for fires under construction actually is arson (36%) followed by hot

work (19%). Unfortunately, the cause of 35% of collected fire incidents remains unknown.

It is important to repeat that the sample is too small to draw conclusions. These results are just a

trigger for further investigations. Contribution form experts (e.g. fire brigades) of the different

countries should be needed to increase the number of entries.

The second task of the study concerns the overview of guidelines, norms and laws regarding to

fire safety of (timber) buildings under construction. First, a broad literature review is undertaken.

Similar works were already conducted in UK [8], Canada [9] and Sweden [10]. Based on the

analysed guidelines, an overview is created and structured as illustrated in Fig. 3.

The general information provides a short description about the origin of the document. Important

aspects are on the one hand the type of the document (regulation, guideline, technical report or

paper / presentation), on the other hand if the document is timber specific or not. Fire safety

objectives are divided in 2 generic types of measures

• Preventive measures to prevent fire events on construction sites: e.g. general fire safety

plan, hot works, fuel sources and storage in general and of flammable products and

protection against arson.

• Fire management measures to fight fire events on construction sites: e.g. alarm and

detection, active protection, compartmentation, protecting, escape routes and access for

the fire brigades.

Significant inputs were received from the experts during the month December 2016 and January

2017. A qualitative overview of all evaluated guidelines is provided in Fig. 5.

Page 39: Book of abstracts of COST FP 1404 MC and WG meeting Action FP1404 Fire Safe Use of Bio-Based Building Products Book of abstracts of COST FP 1404 MC and WG meeting: ”Dissemination,

34

Figure 3. Structure of the overview of the guidelines, papers, regulations and technical reports concerning

the fire safety of (timber) buildings under construction.

Concerning the type of document, it is interesting to notice that 15 countries (on a total of 24 who

provided information) have regulations concerning the fire safety of buildings during the

construction phase but only 2 with timber specific rules (Croatia on national level and Scotland for

the city of Edinburgh). 6 countries (Australia, Canada, Finland, Italy, Sweden and UK) have

guidelines with timber specific recommendations, with the nuance in the Australian guideline

preferring the term “combustible materials” instead of “timber”.

The main input from the collection of guidelines is the subdivision of recommendations in 20

topics plus 2 categories concerning the frame conditions (main responsibility and range of

application) – Fig. 4. The 20 topics are grouped into 2 main chapters as previously mentioned:

“preventive measures” to prevent the fire and “fire management measures”, which come into

operation only once a fire occurs.

For the 20 topics and 2 categories (responsibility and application), first recommendations based

on the collected information have been proposed. The combination of information gathered from

a large span of guidelines from various sectors and countries allows to have specific information

for each topic in a single document. Many of the proposed measures lead to substantial benefits

in terms of fire safety during the construction. However, most of them could be also expensive. A

qualitatively cost-benefit analysis (only subjective evaluation) has been proposed in order to

identify measures that should be particularly efficient.

Page 40: Book of abstracts of COST FP 1404 MC and WG meeting Action FP1404 Fire Safe Use of Bio-Based Building Products Book of abstracts of COST FP 1404 MC and WG meeting: ”Dissemination,

35

Figure 4. Structure of the overview for recommendations about fire safety in timber buildings under

construction

This study has realised a state-of-the-art and established a proposition for a European guideline

on fire safety of timber buildings under construction. Further updates and reviews should be

performed to propose and publish a European guideline on this topic.

Page 41: Book of abstracts of COST FP 1404 MC and WG meeting Action FP1404 Fire Safe Use of Bio-Based Building Products Book of abstracts of COST FP 1404 MC and WG meeting: ”Dissemination,

Fig. 5. Qualitative overview of guidelines regarding fire safety on construction sites

Rating

Nu

mb

er

of

Gu

ide

lin

es

Late

st G

uid

eli

ne

Tim

be

r Sp

eci

fic

Ce

rtif

ied

re

spo

nsi

bil

ity

Spe

cifi

c A

do

pti

on

Safe

ty P

lan

Fire

Sa

fety

Co

ord

ina

tor

Ho

t W

ork

s

Smo

kin

g

Oth

er

Ign

itio

n S

ou

rce

s

Fue

l So

urc

es

Sto

rag

e o

f fl

am

ma

ble

an

d h

igh

ly c

om

bu

stib

le

sub

sta

nce

s

Sto

rag

e i

n g

en

era

l

Ag

ain

st A

rso

n

On

-Sit

e F

ire

pro

ced

ure

s

Lia

iso

n w

ith

Em

erg

en

cy

Serv

ice

s

Te

mp

ora

ry B

uil

din

gs

Ala

rm &

De

tect

ion

Act

ive

Fir

e P

rote

ctio

n

Co

mp

art

me

nta

tio

n

Pro

tect

ing

str

uct

ura

l

Fra

me

Pro

tect

ing

ne

igh

.

Bu

ild

ing

s

Esc

ap

e R

ou

tes

Fire

Fig

hte

r A

cce

ss

Australia* 1 2014 Yes ++ ++ ++ - +++ +++ +++ ++ +++ +++ ++ +++ +++ ++ ++ ++ ++ +++ + ++ ++

Austria 3 2017 No - - ++ ++ ++ + - - ++ - - ++ - - - - - - - - -

Belgium 2 2014 No - - - - +++ - - - ++ - - - - - - + - - - - -

Bulgaria 1 2014 No - + + + + ++ ++ ++ ++ - +++ - +++ + ++ ++ +++ ++ ++ ++ ++

Canada* 2 2014 Yes - - +++ ++ ++ ++ ++ +++ ++ - +++ + +++ - +++ +++ ++ ++ ++ - +

Croatia 4 2011 Yes - ++ +++ ++ ++ ++ ++ ++ +++ - +++ ++ ++ ++ ++ ++ - - + + +

Czech Republic

Denmark

Estonia 1 2010 No - - - - ++ - - - - - - - - - - - - - - - -

EU* 4 2012 Y(1) / N(3) - ++ +++ +++ +++ +++ +++ +++ +++ - +++ + ++ +++ ++ ++ +++ ++ ++ + ++

Finland 1 2014 Yes - - + - - - - - - - - - - - - - - - - - -

France 8 2016 Yes ++ +++ ++ ++ ++ ++ ++ ++ ++ - ++ - - - - - ++ ++ ++ ++ -

Germany 1 2016 No + - - - - + - - ++ ++ ++ - - - - - - - - - -

Greece 0 General Comment: no specific guidelines referring to the fire safety of buildings under construcion, in general

Hungary 1 2014 No - ++ ++ - ++ ++ ++ - + - - - - - - - ++ + - + +

Ireland 1 2013 No + + - - - - - - - - - + - - + ++ - - - ++ -

Italy 3 2013 Y(1) / N(2) - - + +++ - + + + + - - + + - + - - - - + +

Latvia 1 2015 No - - - - - - - - - - - - - - - - - - - - -

Macedonia 3 2013 No + ++ +++ ++ ++ ++ ++ ++ - - - - - - ++ ++ + - + + +

Montenegro

Netherlands

Norway 3 2015 No ++ +++ ++ ++ ++ - - + + + + - - - - - - - - + -

Poland

Portugal

Romania

Scotland** 1 2009 Yes + + ++ + - - - + - - - - - - - - - - - - -

Serbia

Slovakia

Slovenia 3 2008 No ++ ++ +++ +++ ++ - ++ - ++ + - - - - ++ ++ - - - ++ -

Spain 2 2012 No - + ++ - ++ + + ++ +++ ++ - ++ + - +++ ++ + - - + +

Sweden 1 2016 Yes - - +++ + +++ + - + - - - - - - +++ +++ +++ +++ - - -

Switzerland 1 2015 No - - - + + - ++ - + - - - - - - - - - - - +

Turkey 1 2015 No - + + ++ ++ ++ ++ ++ ++ ++ ++ ++ ++ ++ ++ ++ ++ ++ ++ ++ ++

UK 6 2015 Y(4) / N(2) + ++ +++ +++ +++ +++ +++ +++ +++ +++ +++ +++ ++ ++ ++ ++ +++ ++ ++ +++ -

ample

useful

scarce

Aspects

Country

Fire ManagementFrame Conditions Preventive MeasuresGeneral Information

35

Page 42: Book of abstracts of COST FP 1404 MC and WG meeting Action FP1404 Fire Safe Use of Bio-Based Building Products Book of abstracts of COST FP 1404 MC and WG meeting: ”Dissemination,

37

Acknowledgments

We would like to thank Jan Gmür and Eliott Odermatt, students at the ETH Zurich. Without their

commitment during their Project Work “Fire Safety of Timber Buildings under Construction” from

September to December 2016, this study could definitively not have been successfully realised.

Thanks to their structured and pragmatic approach, a big step has been made towards a European

guideline regarding this topic. We would also like to thank all the members of the COST Action

FP1404 and other experts who gave input for the database of fire incidents and for the overview

of the guidelines in their countries.

References

[1] De Geetere L., Ingelaere B. (Belgian Building Research Institute). A new building acoustical concept for lightweight timber frame constructions. Forum Acusticum 7-12 September 2014. Krakow. Poland.

[2] Ingelaere B. (Belgian Building Research Institute). 2012. COST Action FP0702: Net-Acoustics for Timber Based Lightweight Buildings and Elements: Acoustic Design of Lightweight Timber Frame Constructions.

Available from: http://www.wtcb.be/homepage/index.cfm?cat=research&sub=scientific_publications

[3] Fire Safety in timber buildings – Technical guideline for Europe. SP Report. SP Technical Research Institute of Sweden, 2010.

[4] Östman B., (2015 October). Fire Safety Engineering – Opportunities and challenges for Timber Buildings - Proceeding 1st European Workshop Fire Safety of Green Buildings. Berlin. Germany.

[5] Gerard, R., Barber, D., & Wolski, A. (2013, December). Fire Safety Challenges of Tall Wood Building - Final Report. NFPA - The Fire Protection Research Foundation.

[6] Östman, B. (2016). Fire incidents in modern wooden buildings mapped. Brandposten - News from SP Fire Research, 54.

[7] Department for Communities and Local Government. (2012, December). Analysis of fires in buildings of timber framed construction, England, 2009-10 to 2011-12. Department for Communities and Local Government.

[8] Bergulla, J., Mackay, S., & Matthews, S. (2010). Fire Safety on timber frame sites during construction (Vol. 1/4, pp. 2805–2813). Presented at the 11th World Conference on Timber Engineering WTCE, Italy: A. Ceccotti.

[9] Technical Risk Services Inc. (2014, July 25). Report on Course of Construction (Fire) Best Practice Guide. Canadian Wood Council (CWC).

[10] Just, A., Brandon, D., & Noren, J. (2016). Execution of Timber Structures and Fire. Presented at the World Conference on Timber Engineering WTCE 2016, Vienna, Austria.

Page 43: Book of abstracts of COST FP 1404 MC and WG meeting Action FP1404 Fire Safe Use of Bio-Based Building Products Book of abstracts of COST FP 1404 MC and WG meeting: ”Dissemination,

38

Simulation of charring depth of wooden-based products

when exposed to natural fire curves

Jean-Christophe Mindeguia1

1 I2M, University of Bordeaux, 351 Cours de la Libération, 33405 TALENCE Cedex, France, jean-

[email protected]

Keywords: timber, natural fire, performance-based design, pyrolysis, simulation

Justification by calculation of the fire resistance of structures made of wooden-based products is

mainly based on the determination of the thickness of char that is formed at the surface exposed

to fire. For example, the Eurocode 5 part 1-2 proposes a method entitled "reduced cross-section"

which is based on analytical models of charring versus time. Charring models are given for

unprotected and protected structures (by wooden-based panels or plasterboard). This method is

today the most used in engineering to verify or to design timber structures when exposed to fire.

The Eurocode charring models have been validated on the basis of tests carried out with the

standard fire curve [1]. This method is therefore limited to a prescriptive calculation, which can be

very conservative for the structure. Moreover, the Eurocode 5 part 1-2 also offers an analytical

charring model for wooden elements exposed to "parametric" fires but it is limited in time. For a

performance-based design, more advanced fire models are needed. For example, compartment

fire models or CFD software can be used. When using advanced fire models, there is no analytical

model for corresponding charring. In that case, the use of a numerical charring model, coupled to

the fire calculation, is therefore necessary. Some approaches of this kind have been experienced

for steel and concrete constructions and very close studies also exist on wooden-based products

[2], [3], [4]. The aim of this study is to contribute to the use of a performance-based design when

assessing the fire resistance of a wooden structural element. The coupling between different

types of fire models (standard, parametric and 2 zones model) and a numerical model for charring

of wooden-based products is presented.

Firstly, the physical background of the charring model is presented. The model is based on the

thermal diffusion equation in a solid, in which supplementary terms are added in order to take

into account the energy linked to thermal reactions into wood. Water vaporization and pyrolysis

of the different components of wood are simulated by using independent Arrhenius laws. The

thermal properties are calculated at each time step by mixture laws that are controlled by the

reactions rates. The model parameters are then calibrated based on an existing experimental

study where wood samples were exposed to standard and non-standard fire curves [1]. The

calibrated model is then compared to a second experimental study where 9 non-standard fire

curves were tested [5]. The comparison between measured and calculated valued allows

discussing about the importance of thermally-induced thermal reactions into wood, as flaming

and smouldering, especially during the decay phase of low heating rate fire curves.

Page 44: Book of abstracts of COST FP 1404 MC and WG meeting Action FP1404 Fire Safe Use of Bio-Based Building Products Book of abstracts of COST FP 1404 MC and WG meeting: ”Dissemination,

39

Figure 4. Measured temperature and charring depth vs computed values for wood sections exposed to a

parametric fire.

Finally, the model is directly used as a tool for assessing the fire resistance of a common glue-

laminated beam. The structure is exposed to the standard fire curve and to two non-standard fire

curves (parametric fire and a two-zones fire). The results underline the importance for a designer

to correctly choose the fire scenario when assessing the fire resistance of a structure.

References

[1] König, J. and Walleij L. (1999), “One-Dimensional Charring of Timber Exposed to Standard and Parametric Fires in Initially unprotected and Postprotection Situations”, report 1 9908029, Trätek, Stockholm, Sweden, August 1999.

[2] Richter F. and Rein G. (2015), “Numerical simulation of the charring of timber structures under non-uniform fires”, in the proceedings of the 1st European Workshop Fire Safety of Green Buildings, Berlin, Germany, October 6-7 2015, pp. 91-92.

[3] Hopkin, D., Schmid, J. and Friquin, K. (2016), “Timber structures subject to non-standard fire exposure – advances & Challenges”, in the proceedings of the WCTE 2016 World Conference on Timber Engineering, Vienna, Austria, August 22-25, 2016, pp. 3892-3901.

[4] Lange D., Boström L., Schmid J. and Albrektsson J. (2014), “Charring rate of timber in natural fires“, in the proceedings of the 8th International conference on Structures and Fire, Shanghai, China, June 11-13 2014, pp. 521:528.

[5] Werther N. (2016), “External and internal factors influencing the charring of timber – an experimental study with respect to natural fires and moisture conditions”, in the proceedings of the 9th International conference on Structures and Fire, Princeton, USA, June 8-10, 2016, pp. 650-658.

Page 45: Book of abstracts of COST FP 1404 MC and WG meeting Action FP1404 Fire Safe Use of Bio-Based Building Products Book of abstracts of COST FP 1404 MC and WG meeting: ”Dissemination,

40

Fire behaviour and design of beam‐to‐column

steel‐to‐timber dowelled connections

Pedro Palma 1, Andrea Frangi 2

1 Empa – Materials Science and Technology, Switzerland, [email protected] 2 ETH Zurich, Switzerland

Keywords: timber, connections, fire resistance, design

Background

The fire performance of a timber structure is largely influenced by the behaviour of its

connections. Current structural fire design methods for timber connections according to

EN 1995-1-2:2004 [1] are based on empirical rules derived from a limited number of fire

resistance tests on timber connections loaded in tension parallel to the grain. At normal

temperature, connections loaded in the direction parallel and perpendicular to the grain exhibit

very different behaviours, the latter being prone to brittle splitting failures. Given these different

failure modes and with metal fasteners being responsible for increasing charring in the

connection area, a question arose about how different the fire behaviour of connections loaded in

the direction perpendicular to grain would be.

Experimental research

Beam-to-column steel-to-timber dowelled connections were tested at normal temperature and in

fire [2] and reached more than 30 and even 60 min of fire resistance, cross sections with

160×260 cm2 and 240×340 cm2, respectively, for degrees of utilisation Efi / R20°C,mean between 0.23

and 0.39. Most connections failed after extensive embedment deformations in the beam side of

the connection. Aspects such as a wider gap between the beam and the column and the presence

of reinforcement with self-tapping screws decreased the fire resistance, as observed in a previous

study [3]. The failure mode at normal temperature and the dowel diameter did not seem to

influence the fire resistance, suggesting that the thickness of the side members and the degree of

utilisation are more relevant.

Numerical simulations

A framework to model timber connections at normal temperature and in fire, based on combined

finite-element (FE) heat-transfer analyses and temperature-dependent Johansen-type load-

carrying models, was developed [4] and applied in a parametric study of the previously tested

connection typologies. The results showed a clear influence of the thickness of the side members

on the fire resistance of the analysed connections and that a side member thickness t1 = 116 mm

would suffice for reaching 60 min of fire resistance.

Page 46: Book of abstracts of COST FP 1404 MC and WG meeting Action FP1404 Fire Safe Use of Bio-Based Building Products Book of abstracts of COST FP 1404 MC and WG meeting: ”Dissemination,

41

Design of timber connections in fire

Current design rules of EN 1995-1-2:2004 for timber connections in fire were reviewed, taking

into account the experimental research conducted before and after its publication in 2004. Some

design rules are shown to give unsafe estimates of the fire resistance, while others give very

conservative results. New design rules that take into account the experimental research

conducted since the publication of EN 1995-1-2:2004 were formulated [5]:.

fieC20fi

tkRR

⋅−° ⋅= , with 1211)( tcctkk ⋅+== (1)

where fiR is the load-carrying capacity after a given period fit of fire exposure, C20°R is the load-

carrying capacity at normal temperature (or the load-carrying capacity at 0fi =t ), k is the rate of

decay of the load-carrying capacity, 1t is the thickness of the timber side members, and 1c and 2c

are specific parameters for each connection typology.

Figure 1. Proposed and current EN 1995-1-2:2004 models, and experimental results on beam-to-column

connections [2]: a) connections with a side member thickness mm 771 =t (R 30); b) connections with a

side member thickness mm 1171 =t (R 60).

References

[1] EN 1995-1-2:2004 Eurocode 5: Design of timber structures – Part 1-1: General – Structural fire design, European Committee for Standardization (CEN), Brussels, 2004.

[2] P. Palma, A. Frangi, E. Hugi, P. Cachim, H. Cruz, Fire resistance tests on timber beam-to-column shear connections, J. Struct. Fire Eng. 7 (2016) 41–57. doi:10.1108/JSFE-03-2016-004.

[3] P. Palma, A. Frangi, E. Hugi, P. Cachim, H. Cruz, Fire resistance tests on steel-to-timber dowelled connections reinforced with self-drilling screws, in: Proc. 2nd Ibero-Lat.-Am. Congr. Fire Saf. – 2nd CILASCI, Coimbra, Portugal, 2013.

[4] P. Palma, A. Frangi, A framework for finite element modelling of timber connections in fire, in: Struct. Fire – Proc. Ninth Int. Conf., DEStech Publications, Inc., Princeton, USA, 2016: pp. 708–715.

Page 47: Book of abstracts of COST FP 1404 MC and WG meeting Action FP1404 Fire Safe Use of Bio-Based Building Products Book of abstracts of COST FP 1404 MC and WG meeting: ”Dissemination,

42

[5] P. Palma, A. Frangi, Fire design of timber connections – assessment of current design rules and improvement proposals, in: Int. Netw. Timber Eng. Res. INTER – Meet. Forty-Nine, Timber Scientific Publishing, Graz, Austria, 2016: pp. 299–313.

Page 48: Book of abstracts of COST FP 1404 MC and WG meeting Action FP1404 Fire Safe Use of Bio-Based Building Products Book of abstracts of COST FP 1404 MC and WG meeting: ”Dissemination,

43

Current state of working group 2:

Fire behaviour of CLT

Michael Klippel1, Norman Werther2, Birgit Östman3

1 Institute of Structural Engineering, ETH Zurich, Switzerland [email protected]

2 Chair of timber structures and building construction, Technische Universität München,

Arcisstrasse 21, 80333 Zürich, Germany, [email protected]

3 Linneaus University, Växjö, Sweden, [email protected]

Keywords: Cross-laminated timber; fire behavior; fire tests; charring rate; fire design

Introduction

Cross-Laminated Timber (CLT) is currently used in modern timber for load-bearing wall, floor or

roof elements as a high quality, innovative and cost-effective structural element. Careful planning

and implementation ensures the safe use of CLT in buildings with increased fire protection

requirements and in accordance with the requirements of building-design standards (e.g. EN

1995-1-1 and EN 1995-1-2) [1,2]. Task group 1 of working group 2 of this COST Action aims to

deliver important information for the fire design of CLT to be used for the revision of the fire part

of Eurocode 5. This abstract summarises the current state of the work and the planned next steps.

Current state of work

The fire part of Eurocode 5 is currently under revision and should include information on the fire

design of CLT, which is not included in the present version of Eurocode 5. However, fire design models

for CLT are already available in the European technical guideline for fire safety in timber buildings [1],

in the scientific literature and probably also in different national guidelines and all this information will

of course be used as input for the revision of Eurocode 5 and improved as much as possible.

This revision work is coordinated within the Working Group 4 of CEN/TC 250/SC5 chaired by Andrea

Frangi (ETH Zurich, Switzerland) with participants from several countries active in the field. Further,

the revision is supported by this task group and the global “Fire Safe Use of Wood (FSUW)” network.

A reliable model for the fire design of CLT needs to be verified and compared with fire test data in

order to be useful and not too conservative for an economical design. There are some fire test data

published in the scientific literature that can be used. These tests are summarized in a database and

provide important information to be used during the revision of Eurocode 5.

There are also data from fire tests that different producers have performed within the certification

process of their products. Those data are the property of the producers and some of these tests have

been incorporated in the database already.

Page 49: Book of abstracts of COST FP 1404 MC and WG meeting Action FP1404 Fire Safe Use of Bio-Based Building Products Book of abstracts of COST FP 1404 MC and WG meeting: ”Dissemination,

44

Based on the comprehensive overview on fire tests with CLT elements taken from this database,

the European charring model and other models (such as a Canadian charring model, a Japanese

charring model, an US charring model, etc.) have been compared to test results. The char depth of

initially unprotected CLT wall and floor elements is taken from the database (based on the fire

test reports) and compared to the char depth calculated according to the different charring

models. Fig. 1 shows a comparison of the char depth obtained from fire tests with the European

charring model for initially unprotected CLT elements as an example.

Figure 1. Char depth comparison obtained from fire tests with the European charring model for initially

unprotected CLT (according to [3])

The following conclusions can be drawn for initially unprotected CLT elements on the basis of

Fig. 1, and according to [3]:

• The European charring model gives mainly conservative results, meaning that the char depth predicted by the model is usually greater than the char depth obtained in the fire tests.

• The difference of char depth between the model and the fire tests increases with increasing time of fire exposure, demonstrated by the dashed trendline. That means that the model becomes more conservative with increasing time of fire exposure.

• The difference between the model and the fire tests for a fire resistance of 60 minutes is only about 2 minutes.

• The European model overestimates the char depth on average by 5 mm. Assuming a one-dimensional charring rate of 0.65 mm/min this results in a difference with respect to the fire resistance of about 8 minutes.

Additional to the charring rate, the zero-strength layer d0 for CLT has been investigated. The work

will be published soon.

Planned next steps

The next steps of this task group are directly related to the work of CEN/TC 250/SC5. It is planned

to provide the following possibilities to perform the fire design of CLT in the future Eurocode 5:

Page 50: Book of abstracts of COST FP 1404 MC and WG meeting Action FP1404 Fire Safe Use of Bio-Based Building Products Book of abstracts of COST FP 1404 MC and WG meeting: ”Dissemination,

45

1. Tabulated data

2. Simplified design method

3. Advanced design method

This task group will support the work performed within the revision of Eurocode 5. Interested people

are welcome to join.

Acknowledgments

The authors gratefully acknowledge the European COST Action FP1404 on the Fire safe use of bio-

based building products.

References

[1] EN 1995-1-1 (Eurocode 5) (2004): Design of timber structures, Part 1-1: General – Common rules for buildings, CEN, Brüssel.

[2] EN 1995-1-2 (Eurocode 5) (2010): Design of timber structures, Part 1-2: General – Structural fire design, CEN, Brüssel.

[3] M. Klippel, J. Schmid, Design of cross-laminated timber in fire, Structural Engineering International, 2017, accepted for publication

[4] Falk, Andreas, Philipp Dietsch, and Joachim Schmid. "Proceedings of the Joint Conference of COST Actions FP1402 &amp; FP1404 Cross Laminated Timber: A competitive wood product for visionary and fire safe buildings." Joint Conference of COST Actions FP1402 & FP1404 Cross Laminated Timber. KTH Royal Institute of Technology, 2016.

Page 51: Book of abstracts of COST FP 1404 MC and WG meeting Action FP1404 Fire Safe Use of Bio-Based Building Products Book of abstracts of COST FP 1404 MC and WG meeting: ”Dissemination,

46

Working Group 3

Regulations for fire safety of bio-based building materials

Page 52: Book of abstracts of COST FP 1404 MC and WG meeting Action FP1404 Fire Safe Use of Bio-Based Building Products Book of abstracts of COST FP 1404 MC and WG meeting: ”Dissemination,

47

Report on building regulation concerning the bio based

building products in Hungary

Tamás Herzeg1

1 Architect, associate professor University of West Hungary, Hungary, [email protected]

Keywords: Priorities, Fire protection and resistance, Wood, Tradition, Deviation

In Hungary there is a new fire safety regulation1 valid since 2014, which is intended to secure a

harmonization with the EU laws. The EU defined the Fire Protection Categories and their

specifications. All buildings must be classified into risk classes according to their capacity, to their

vertical dimension by height and depth and to their capacity to escape of persons. The building

constructions, components and materials must be classified into Fire Protection Classes and

specified according to the Fire Resistance Regulations. The definition of the detailed

requirements of these classes is a national competence and has to be formulated by the

members. The Fire Protection Technical Directives in Hungary provide only requirements which

can help planning but they don’t give any actual solution proposals. So these are the legislative

framework which doesn’t contains any dedicated regulations for named materials and products.

Not even the words like “steel, wood, concrete, RC” etc. are really mentioned in this laws.

Obviously, there are no references in them neither for the bio based building products. For

helping with the fire safety classification of the building products there are some Fire Protection

Audits by the EU and some by the National Institute for Quality Control (ÉMI) but these concern

mainly to constructions and materials belonging to proven building systems and not to innovative

products and solutions. The use of the bio based building products in small-scale buildings are

very traditional either as constructions or as cover materials and it is not very difficult to correlate

them to the Fire Regulations. But their use in Hungary in large-scale buildings as construction

elements reckon, or rather, would reckon among innovative solutions. Bio based building product

in Hungary means first of all the wood. The planning and design using wood for construction

elements, for example, in a multi-story building demand lots of innovative powers because of the

fire regulations, but it is not an impossible challenge in principle. At the same time there are a lot

of difficulties in practice which counteract the wider use of bio based products (wood) by

construction of a large scale building:

1. The principle of the Fire Protection of the building products traditionally has intense

dominance. In countries such as in England or in Germany where the requirements are

better concerning the use of bio based products (wood) in a multi-story large-scale building

the regulation focus more on the Fire Resistance.

2. In this context the Safeguarding of valuables and the Protection of lives are on the same

importance level in Hungary, while the priority of the Safeguarding lives would help using of

innovative products.

Page 53: Book of abstracts of COST FP 1404 MC and WG meeting Action FP1404 Fire Safe Use of Bio-Based Building Products Book of abstracts of COST FP 1404 MC and WG meeting: ”Dissemination,

48

3. The passive fire protection traditionally is still dominant opposite the active solutions which

has of course financial reasons, too.

4. Nowadays the planners and designers have the application for the deviations from the norm

as the only device for building something different from the ordinary. These applications

usually can work but the solutions and the approval are always unique and often accidental

rather than comprehensive and focused on the complexity of the project. A complex Fire

Protection Conception for the whole project elaborated in cooperation by the authority and

the planners could create a positive condition for using bio based products.

Figure 1. Family house in Zsida, Gábor

U. Nagy

Figure 2. Pajta in Őriszentpéter, Gábor U.Nagy

Acknowledgments

Special thanks to Prof. Tibor Alpár, Gábor U. Nagy, Péter György Horváth, Károly Wágner

References

[1] Decree (XII.5.) 54/2014 BM of the Minister of the Interior on the National Fire Protection Regulations.

Page 54: Book of abstracts of COST FP 1404 MC and WG meeting Action FP1404 Fire Safe Use of Bio-Based Building Products Book of abstracts of COST FP 1404 MC and WG meeting: ”Dissemination,

49

Fire-fighting concepts for buildings made from bio-based

products

Kamila Kempná 1, Jan Smolka 1, Miloš Kvarčák1

1 Lumírova 13, Ostrava, FBI VŠB-TUO, Czech Republic, [email protected]

Keywords: fire, fire-fighting, timber buildings, equipment, extinguishing, conception, bio-

based materials, fire safety

Fire-fighting conception as a system of fire-fighting procedures is developing with new challenging

building constructions, new materials and new fire-fighting equipment. Primary mission of fire

and rescue services is to protect life, health and property of citizens against fire and to provide

effective help in emergencies. In the event of fire many aspects are important especially if

a building is constructed from flammable bio-based building products.

Fire-fighting conception is an important system of effective ensuring of fire safety related

to current situation, including organisation, operational procedures, area coverage etc. With

regards to current increasing number of timber buildings and lack of knowledge and experience

with real fires in Europe, research to specify main risks, safety limits, extreme fire behaviour

as well as best practice are highly needed.

Strategy of fire-fighting

Fire-fighting conception is affected by various factors, which response to current situation

in a country. Some of them are stated below:

- Economic factors (Fire-fighting equipment, number of fire stations, number of stuff)

- Local dangers (fabrics, mines, forests, …)

- Traditions and culture of fire safety protection (voluntary fire-fighters, population ability

of danger awareness, …)

- Geographical situation (population density, area, weather, …)

- Traditions of building conception (depending on local access to building materials and their

prices)

- Regulations, etc.

All these aspects affect establishing of fire-fighting conception and its planning which includes

building of new fire stations, local fire brigade equipment, area coverage setting by fire and

rescue service (including category of fire units – response time of units in case of emergency),

designing of extinguishing systems in buildings, fire-fighting plans, etc.

Page 55: Book of abstracts of COST FP 1404 MC and WG meeting Action FP1404 Fire Safe Use of Bio-Based Building Products Book of abstracts of COST FP 1404 MC and WG meeting: ”Dissemination,

50

Many of bio-based buildings are used as dormitories, offices, schools, hospitals, etc. which specify

unusual conditions for effective rescuing and extinguishing. Special fire-fighting documentation is

used as supported documentation for fire-fighting in these buildings. The documentation includes

recommendation for commanders, special risks, type of construction, recommended

extinguishing equipment and agents, recommended fire-fighting routes, etc.

Various approaches in Europe - example

Each country has its own conception with respect to current situation. Sweden with almost six

times larger area than the Czech Republic has similar number of population.

In Sweden, it is more traditional and usual to build timber structures than in the Czech Republic.

For example, Sweden has much lower density population and more extreme weather

phenomena. Additionally, population in countries have different approach to fire prevention. The

conception is quite different in comparison with the Czech Republic.

In comparison, each country has different response time in case of fire, different number of

voluntary and professional fire-fighters, equipment, and fire stations cover different area.

Risks for fire-fighters

Fire-fighters should be informed about special risks related to structure and material behaviour,

for example if steel construction achieved temperature higher than 400°C, entering of fire-fighters

into the building is not recommended. Similar recommendation should be developed for new bio-

based buildings (if steel joint achieve 400°C, inform about light-weight/heavy-weight type of

construction, etc.).

Bio-based materials and new types of construction use represent risk in event of the fire, for

instance:

- Extensive use of engineered wood-frame construction

- Synthetic fire loading in the interior and in the exterior

- Void spaces

- Open floor plan/atrium-like design living spaces (lack of compartmentation allows faster fire

development and spreading)

- Fire involvement throughout, etc.

As new materials are developed, fire-fighting conditions and aspects should be further researched

and implemented in fire-fighting tactic, training and equipment.

Main goal of WG3TG1 is to summarise and compare possible risks and dangerous behaviour of

bio-based materials in fire, as well as experience from fire-fighters and the best practice of various

fire-fighting equipment and agents. This work should help fire-fighters to react to changes of

wider use of bio-based materials.

Page 56: Book of abstracts of COST FP 1404 MC and WG meeting Action FP1404 Fire Safe Use of Bio-Based Building Products Book of abstracts of COST FP 1404 MC and WG meeting: ”Dissemination,

51

Construction site fire safety – UK experience

Tom Lennon

Fire Safety, BRE Global, Bucknalls Lane, Watford WD25 9XX, UK

Keywords: fire safety, construction, risk assessment

The purpose of this presentation is to explain the background to the current UK provisions in relation to fire safety on construction sites where the principal method of construction is timber frame (including light timber framing, Cross Laminated Timber panels and Structural Insulated Panel systems).

The presentation will explain the background to the current situation and describe the response provided by the UK Structural Timber Association (STA).

The presentation will focus on a number of incidents where large fires have occurred during the construction phase to identify the important issues to be addressed (speed of fire spread, radiated heat to adjacent buildings, partial occupation of completed buildings within the site boundary).

The issue will be addressed in relation to regulatory issues and the provision of guidance to the construction industry on risk mitigation factors and the preparation of a Fire Safety Plan for the construction phase for large timber frame construction sites.

In addition to guidance on risk mitigation STA members have to comply with Site Safe Guidance which includes registering all large construction sites on a confidential web site run by the UK Fire Service.

The UK STA have issued guidance for dealing with the off-site risk of a fire on a timber frame

construction site impacting on adjacent buildings outside the site boundary. Easy to use tables are

provided to specify the minimum separation distances based on the area of the potential emitting

surface. The allowable separation distance is a function of the form of construction. Test and

assessment procedures are in place to classify construction products based on ignitability and

reaction to fire properties during the construction phase (Figure 2).

Page 57: Book of abstracts of COST FP 1404 MC and WG meeting Action FP1404 Fire Safe Use of Bio-Based Building Products Book of abstracts of COST FP 1404 MC and WG meeting: ”Dissemination,

52

Figure 1 Fire during the construction phase of a

large timber frame project.

Figure 2 STA Small room fire test for assessment and

classification of construction products

References

[1] Health and Safety Executive, Fire safety in construction, HSG 168 Second Edition, HSE Books, Crown

Copyright 2010.

[2] Structural Timber Association, 16 Steps to fire safety – Promoting good practice on timber frame

construction sites, 3rd

Edition September 2014, available from http://www.structuraltimber.co.uk/ (last

accessed January 2017).

[3] Structural Timber Association, Design guide to separating distances during construction –For timber

frame buildings above 600m² total floor area, Version 2.1 December 2012, available from

http://www.structuraltimber.co.uk/ (last accessed January 2017).

Page 58: Book of abstracts of COST FP 1404 MC and WG meeting Action FP1404 Fire Safe Use of Bio-Based Building Products Book of abstracts of COST FP 1404 MC and WG meeting: ”Dissemination,

53

Background to building regulations – Change of fire safety

regulations in Finland

Esko Mikkola1

1 KK-Fireconsult Ltd, Espoo, Finland, [email protected]

Keywords: fire exposure, HC fire curve, charring rate, visible timber, requirement

Background

Changes of fire safety regulations in Finland have occurred quite regularly: 1997 performance

based fire safety design was made possible and timber framed buildings up to 4 storeys

(residential and office) came possible according to prescribed rules; 2002 European reaction to

fire classes were implemented; 2011 timber framed buildings up to 8 storeys (residential and

office) were made possible according to prescribed rules. The next change is planned to be at the

beginning of 2018.

Several background studies during 2015 and 2016 have been carried out to further develop the

Finnish fire safety regulations. The topics have included e.g.:

- clarification of the regulations and guidance to reduce different interpretations,

- extension of prescribed rules of maximum 8 storey building to covers also other than

residential and office buildings,

- conditions for use of timber structures without coverings in building with more than two

storeys, and

- protection of insulation materials which are not at least A2 or B class.

One of the studies is shortly summarised in the following. Background for this study arises from

the basic principles for timber framed buildings (more than 2 storeys) in the Finnish regulations:

Both sprinklers and coverings (K210 or K230 with A2 material) are required. And the probability of

structural failure shall be at the same level as for buildings with at least A2 class structures.

Fire exposure

As a starting point a design fire exposure curve was generated for the situation where load

bearing structures are made of visible massive timber and sprinklers fail (or are not installed). The

structures may be protected partly by gypsum board, or may be totally unprotected.

First a probabilistic approach using parametric fire curves was applied to find out possible fire

exposure levels and effects of openings. Parametric temperature-time curves according to

Eurocode EN 1991-1-2 do have a linear decay slope which reached low (original) temperatures

faster than in reality. The walls, ceiling and floor stay warm for a long period (in a non-collapsed

room) and there may be also some residue of the movable fire load glowing on the floor.

Parametric fire curves are quite close to the HC (Hydro Carbon) fire curve for the first half an

hour. After that the parametric curves are higher until short after the decay phase has started.

In Figures 1 and 2 experimental results are given for temperature developments in room fire tests with massive timber structures which have been totally or partly protected or there has been no

Page 59: Book of abstracts of COST FP 1404 MC and WG meeting Action FP1404 Fire Safe Use of Bio-Based Building Products Book of abstracts of COST FP 1404 MC and WG meeting: ”Dissemination,

54

gypsum board protection at all. When having a lot of wood visible the temperature-time curves are quite close to the HC fire curve which reaches 1100oC in 30 minutes and stays there.

Figure 1. Room with 660 MJ/m2 movable fire load.

About half of CLT walls and ceilings visible [2]. Figure 2. Room with less than 350 MJ/m

2 movable

fire load when wooden floor excluded [3].

The difference between total energy (fire exposure to the structures) of the HC fire curve and the standard temperature-time curve which is used in fire classification of structural members is illustrated in Figure 3.

Figure 3. Fire exposure comparison in energy between HC and standard temperature-time curves.

Based on results of the probabilistic parametric fire curves and comparisons with real scale experimental results it was decided to use the HC curve as a fire exposure design curve for measuring charring rates of structural members.

Charring rates

Measured one-dimensional charring rates [4] for standard fire exposure are given in Table 1 and

for HC fire exposure in Table 2. The following specimen were included in the test series: LVL (fire

exposure perpendicular to laminations and in direction of laminations), CLT (fire exposure

perpendicular to lamellas and in direction of lamellas), solid timber and glued laminated timber.

0

200

400

600

800

1000

1200

1400

0 10 20 30 40 50 60 70 80 90 100 110 120

En

erg

y (

MJ/

m2)

Time (min)

HC

EN 1363-1

Page 60: Book of abstracts of COST FP 1404 MC and WG meeting Action FP1404 Fire Safe Use of Bio-Based Building Products Book of abstracts of COST FP 1404 MC and WG meeting: ”Dissemination,

55

Table 1. One-dimensional charring rates (standard fire exposure).

Time from start

Charring rate (mm/min)

LVL LVL CLT 40 mm lamella

CLT 40 mm lamella

Sawn timber

Glulam

30 min 0.62 0.60 0.70 0.73 0.65 0.68

60 min 0.66 0.62 0.66 0.71 0.62 0.61

90 min 0.64 0.63 0.73 0.70 0.61 0.59

120 min 0.62* 0.63* 0.61* 0.59* *Estimate

Table 2. One-dimensional charring rates (HC fire curve).

Time from start

Charring rate (mm/min) HC

LVL LVL CLT 40 mm lamella

CLT 40 mm lamella

Sawn timber

Glulam

30 min 1.24 1.27 1.16 1.24 1.12 1.15

60 min 1.07 1.08 1.15 1.01 0.92 0.95

90 min 1.03 0.97 1.09 0.85 0.82 0.84

120 min 1.08* 0.95* 0.75 0.79* 0.76* *Estimate

Load bearing requirements

For the design of load bearing timber elements it is essential to define requirements using the R

classification values also for performance based fire exposures such as the HC fire curve in this

case.

The R60 requirement corresponds the 600 MJ/m2 fire load density limit in the Finnish regulations.

When this requirement is given in terms of total energy of fire exposure, it can be assumed that

certain safety factors must be included in the required R levels. Thus it has been proposed that

the 600 MJ/m2 fire load density limit includes the contribution of 20 % of visible structural wood

surfaces on walls and ceiling (see Figure 4).

Concerning safety of rescue personnel, it is assumed that there will be no collapse of load bearing

structures during one hour (real time) of natural fire development. Total energy exposure the

structures in a test with HC fire curve during one hour is about 700 MJ/m2. This corresponds fire

exposure during 107 minutes under standard fire curve conditions (Figure 4).

For HC fire exposure the one-dimensional char depth was not more than 65 mm in 60 minutes for

LVL, sawn timber and glulam [4]. This corresponds char depth at 100 minutes under standard fire

curve conditions (Figure 4).

In Figure 4 it has been assumed that the total energy of fire exposure increases linearly with

increasing area of visible timber structures. Thus also a linear model for R equivalency based on

energy and char depth is applied. The percentage value of visible structures is calculated for the

walls and ceiling, not taking floor into account.

Page 61: Book of abstracts of COST FP 1404 MC and WG meeting Action FP1404 Fire Safe Use of Bio-Based Building Products Book of abstracts of COST FP 1404 MC and WG meeting: ”Dissemination,

56

Figure 4. Total energy during 60 min fire exposure and R equivalency as a function of

percentage of visible timber structures.

Conclusions

Scientific studies are needed to form solid background for changes of national fire regulations. In

the described study key finding were the following:

- HC fire can be used to describe situations were large areas of timber structures are exposed

to fire and there are no sprinklers or they fail.

- Increase in charring rate caused by a higher fire exposure can be taken into account with

increased fire resistance requirements (which are based on standard fire exposure).

- Char depths in timber structures can be calculated based on standard Eurocode 5 rules and

product specific calculation guides.

Acknowledgments

Puutuoteteollisuus ry and the Confederation of Finnish Construction Industries are thanked for

financial support. COST Action FP 1404 is thanked for providing a forum for information transfer.

References

[1] Esko Mikkola, Tuomo Rinne ja Mikko Granström. Massiivisten puurakenteiden laajennettu käyttö ilman suojaverhousta – perustelut ehdotukselle palomääräyksiin. KK-Palokonsultti Oy, 12/2016. (In Finnish)

[2] Hox, K. Branntest av massivtre. SP Fire Research AS. SPFR-rapport SPFR A15101. 2015-03-18.

[3] Xiao Li, Cameron McGregor, Alejandro Medina, Xiaoqian Sun, David Barber, George Hadjisophocleous. Real-scale fire tests on timber constructions. WCTE 2016, Vienna, Austria.

[4] One-dimensional charring of solid timber, glued-laminated timber, LVL and CLT. Test re-port No. VTT-S-04746-16. November 25, 2016. VTT Expert Services Ltd.

Page 62: Book of abstracts of COST FP 1404 MC and WG meeting Action FP1404 Fire Safe Use of Bio-Based Building Products Book of abstracts of COST FP 1404 MC and WG meeting: ”Dissemination,

57

Serbia: Fire safety in regulations, research and future

challenges

Mirjana Laban1, Tatjana Kočetov Mišulić2, Suzana Draganić3, Igor Dzolev4

1Trg Dositeja Obradovića 6, Novi Sad 21000, Department of Civil Engineering and Geodesy, Faculty

of Technical Sciences, University of Novi Sad, Serbia, [email protected]

2,3,4 Trg Dositeja Obradovića 6, Novi Sad 21000, Department of Civil Engineering and Geodesy,

Faculty of Technical Sciences, University of Novi Sad, Serbia

Keywords: Timber structures, Fire regulations, Education, Research

Timber constructions sector in Serbia – overview

Serbia is a country with about 27% of total area covered by forests, what is estimated as 65% of

optimal forest cover (considering ecological, social and economic parameters in harmonic

correlation). Broad-leaved stands represent 86.4%, coniferous stands 6.8% and mixed stands

about 6.8%. [1]. As a consequence of poor natural coniferous wood resources and sawn softwood

production, the import of technical construction timber is present (Bosnia & Herzegovina, Ukraine

and recently from Austria and Russia).

Serbian building heritage includes wooden churches and monasteries as well as numerous

historical buildings in rural and central urban areas, completely (walls, etc.) or partially (only roofs

and ceilings) made by wood. Traditional buildings by local poplar wood and mud mixed with

straw, covered and enforced by reed are present in north region of Serbia, i.e. Vojvodina (Fig. 1).

Figure 1. Traditional housing in Vojvodina Figure 1. Timber prefabricated modular house

Today concrete (RC, AAC), steel and brick (clay products) dominate in residential or public building

in Serbia. The official statistics show that the percentage of wooden houses is about 1% of total

housing (residential homes) construction in Serbia. Although the wood is not a dominant building

material in Serbia, it could be said that it is inevitable: traditional roof structures made by solid

timber are still dominantly used in residential buildings, both in single family houses and multi-

Page 63: Book of abstracts of COST FP 1404 MC and WG meeting Action FP1404 Fire Safe Use of Bio-Based Building Products Book of abstracts of COST FP 1404 MC and WG meeting: ”Dissemination,

58

levelled apartment blocks. Engineered wood prefabricates, such as light-frame trusses connected

by punched metal plates, are frequently used for rehabilitation of flat roofs in urban areas. Other

prefabricates (such as LVL, “I” joists and beams etc.), are not in use because there is no domestic

production. Residential prefabricated modular houses (Fig. 2) made by timber frame panel walls

finished by timber board (OSB, particle, veneer, plywood, etc.), recently (after a severe

earthquake in 2010) achieved significant progress because of rapid installation and good

performance in cases of seismic events. Massive wall timber systems in form of log homes are still

partially used for rest houses. Glulam products are usually used for sport halls, swimming pools,

hotels, small bridges and other public representative buildings or special canopies.

Technologically advanced products, such as cross laminated timber (CLT), are not present in

modern construction sector in Serbia.

Fire Safety Regulations in Serbia

In Serbia fire regulation codes were traditionally based on prescriptive approach, until 2009 when

the new Fire Protection Law introduced performance based design and risk analysis. All facilities

have to be categorized by Fire inspectors (Sector for Emergency Management – Directorate for

preventive protection, Ministry of Interior RS) according to vulnerability to fire. It depends on

technological process, the type and amount of material that is produced, processed or stored,

type of material used for construction and the importance and size of a building. There are 3 fire

risk categories (FRC): (1) High fire risk, (2) Increased fire risk and (3) certain fire risk.

Both in the conceptual design phase and in the main design project phase, it is obligated to

submit separated volumes of technical documentation (Fire protection Elaborate and Fire

protection Main Design Plan, respectively) in order to prove that the building meets the basic fire

safety requirements: the load-bearing capacity of the structure can be assumed for a specific

period of time, the generation and spread of fire and smoke within the building are limited, the

spread of fire on neighbouring buildings is limited and to insure safe and timely evacuation or

rescue of occupants. Basic requirements are considered as fulfilled if foreseen fire protection

measures are in accordance with technical rules, standards and fire risk assessment. The risk

assessment is obligatory to be done for all buildings. Fire protection Law demands fire detection

systems for hotels, department stores, shopping centres, cinemas, kindergartens, schools, higher

education institutions, cultural institutions, medical facilities, sports and concert halls, stadiums

with commercial space, airport buildings and tall buildings, regardless of the results of risk

assessment. Additionally, the risk assessment is obligatory for proving that there is no need for a

suppression system for those facilities. All tall buildings, except residential, have to be equipped

with fire suppression systems.

The Serbian Building Codes (SBC) consider the wood based structures in general as “combustible”.

In fire risk classification and analysis, SBC do not treat differently timber or timber based

structures due to applied type of wood or wood based product, cross-sectional area of elements

or applied structural system and type of structural connections. The number of stories is not

strictly limited by Fire safety codes, because buildings with main timber structure are generally

Page 64: Book of abstracts of COST FP 1404 MC and WG meeting Action FP1404 Fire Safe Use of Bio-Based Building Products Book of abstracts of COST FP 1404 MC and WG meeting: ”Dissemination,

59

constructed as low-rise buildings with max two stories. Bio-based materials are not considered in

SBC, although they are traditionally present in old residential houses, and there is strong intention

of their use in new energy efficient buildings as insulating materials (particularly straw and types

of timber and bio waste). Some fire safety requirements for timber buildings could be found as

parts of different structural codes for timber structures, mostly as empirical ones, and they are

dealing with construction protection measures, chemical protection of wood and safety

protection claddings with non-combustible sheets. As the test furnaces for full scale testing do not

exist in the country, the attestation of fire performance is limited and oriented to prefabricated

wood-based panel walls covered with gypsum sheets.

Most important for fire safety are the regulated fire safety standards (Building Code) that provide

integrated fire suppression systems such a sprinklers, fire rated wall and floor assemblies, and fire

separation of habitable spaces from emergency exits. Under this proposal, such fire safety

systems would be identical for tall wood buildings and tall steel or concrete buildings, only the

construction material would be different.

Education and Research

In higher educational system in Serbia, Fire Safety Engineering studies are accredited at a few

Higher Education Institutions (2 academic and 4 applied study programmes). At Department for

Civil Engineering and Geodesy (University of Novi Sad, Faculty of Technical Sciences), academic 5-

years/300 ECTS study programmes Civil engineering and Disaster Risk Management & Fire Safety

Engineering are running simultaneously. As Serbia is in the process of adoption of EU building

codes and Directives, the study programmes are innovated in order to be complementary and

synchronized. It is expected that Erasmus+ project "K-FORCE", started in 2016, October, will speed

up modernization Master and development of PhD studies in this field. The synergy of two study

programmes is visible in several high quality master and PhD thesis, that are finished or in

progress. In lack of testing laboratories, the main focus of the research is oriented to numerical

modelling of fire performance of building elements.

Challenges

The main challenge in domain of timber structure and fire safety in Serbia is to deliberate modern

timber products and bio-based materials from numerous preconceptions and administrative

obstacles. With continuous data collection about previous and actual fires of timber based

structures, with more detailed description about structural systems and used connections and

(non)existing fire protection, it could be possible to develop the risk matrices and to influence

correlation between risk categories and modern timber products present at the Serbian market.

In lack of experimental opportunities, the focus of numerical modeling has to be based on foreign

fundamental research about charring rates of different types of wood, data that includes the

contribution of other present combustible materials to fire performance of timber structure and

data about metal connection behavior. Also, the introduction of existing proved details suitable

Page 65: Book of abstracts of COST FP 1404 MC and WG meeting Action FP1404 Fire Safe Use of Bio-Based Building Products Book of abstracts of COST FP 1404 MC and WG meeting: ”Dissemination,

60

for implementing in Serbian practice will also be one of the tasks, in order to enhance the existing

codes.

References

[1] Medarević M., Banković S., Šljukić B. 2008. Sustainable forest management in Serbia: State and

potentials. Glasnik Šumarskog fakulteta, Beograd, 97: 33-56 (in Serbian)

Page 66: Book of abstracts of COST FP 1404 MC and WG meeting Action FP1404 Fire Safe Use of Bio-Based Building Products Book of abstracts of COST FP 1404 MC and WG meeting: ”Dissemination,

61

Designers’ Opinions on the Use of Bio-based Materials in

Buildings

Andrew Macilwraith1, Maria Pilar Giraldo2, Kathinka Leikanger Friquin3, & Ayfer

Donmez Cavdar 4.

1 Cork Institute of Technology, Rossa Avenue, Bishopstown, Cork, Ireland,

[email protected].

2 Forest Sciences Centre of Catalonia-INCAFUST, Av. Dr. Maranón 44, Barcelona, Spain ,

[email protected]

3 SINTEF Building and Infrastructure, Høgskoleringen 7b, Sluppen, 7465 Trondheim, Norway,

[email protected]

4 Faculty of Architecture, Karadeniz Technical University, 61080, Trabzon, Turkey.

[email protected]

Abstract

This study aims to evaluate building designers’ views of construction using bio-based materials

and timber, across Europe in terms of; sustainability, Eurocode 5 (EN 1995), construction

materials, combustibility, sprinkler or deluge protection, and fire retardant treatments or

impregnations. It will provide an indication of designers’ opinion on the use of bio-based materials

and timber using Lime Survey. In summary, designers are generally aware of the sustainability

benefits of these materials, however there is a definite concern in relation to the combustibility of

these materials. There is overall a general acceptance that sprinklers, and surface coatings or

impregnations may help to alleviate the issue to some degree.

Keywords: Bio-based, timber, designers, buildings, opinions

Introduction:

There is an increased number of researchers investigating the properties of timber and other bio-

based materials, many driven by an overarching theme to improve the carbon footprint of our

buildings (Lawrence 2014, Lawrence 2015, Fan and Fu, 2017 ). However the use of timber as a key

structural material in buildings is still very much the exception, rather than the rule. Each time

that a building is envisaged at concept stage, the overall building envelope is chosen, the main

structural materials are decided upon, and whether large amounts of exposed bio-based surfaces

Page 67: Book of abstracts of COST FP 1404 MC and WG meeting Action FP1404 Fire Safe Use of Bio-Based Building Products Book of abstracts of COST FP 1404 MC and WG meeting: ”Dissemination,

62

will be part of the building features. The building designers, such as architects, interior architects,

and structural engineers, have an important role in deciding (Haroglu, 2009) whether timber or

other bio-based materials are used.

In order to ascertain designers’ opinions on the use of timber and other bio-based materials in

buildings, an online survey, using Lime Survey, was undertaken. This survey covered areas such as;

sustainability, EN 1995 (Eurocode 5), materials most commonly used in construction,

sprinkler/deluge protection, coatings, impregnations, and the potential for a 3rd party review of

designs. 161 responses from designers primarily from across Europe were received, however

some did not complete all of the 23 questions asked.

Importance of Sustainability: Very few designers disagree that timber and bio-based materials

are more sustainable than other building materials, however 1 in 4 designers are neutral in their

views. As can be seen in Figure 1, only 50% of those designers who agree that timber and bio-

based materials are more sustainable are in favour of increasing its use in their buildings. This

could be due to lack of familiarity, concerns over combustibility, concerns over durability,

additional costs, and larger member size in some cases.

Figure 1. Sustainability & Use of Timber & Bio-based Materials in Buildings

Eurocode 5 (EN 1995): Many designers do not appear to have transferred over to the Eurocode

from their existing older timber design codes and standards, (See Figure 2 below). This can often

be the case if one is only designing in a material very infrequently, then the lead in time to

become familiar with a large code may encourage a designer to remain with an earlier code, even

though it may have been superseded. It is good to see that there is only minimal disagreement

with the statement that “Eurocode 5 is an improvement”, showing the standard in a good light.

However there may be some cause for concern, as many designers are in agreement, while a

lesser number of designers are willing to strongly agree that EN 1995 is an improvement. There is

also over one third of designers neutral or unconvinced that Eurocode 5 is an improvement. This

may be due to unfamiliarity with EN 1995, or it may be due to the complexity of the document,

while very suitable for larger more complex buildings, may be somewhat unwieldy for smaller

simpler projects.

0

20

40

60

Strongly in

Favour

In Favour Neutral Disagree Strongly

Disagree

Is your firm in favour of

increasing the use of timber

and bio-based materials in

buildings?Is it your view that bio-based

materials are more

sustainable than other

building products?

Page 68: Book of abstracts of COST FP 1404 MC and WG meeting Action FP1404 Fire Safe Use of Bio-Based Building Products Book of abstracts of COST FP 1404 MC and WG meeting: ”Dissemination,

63

Figure 2. % Buildings designed to Eurocode 5. Figure 3. Is Eurocode 5 an Improvement

Construction Materials: As shown in Figure 4 below, reinforced concrete appears to be the most

commonly used structural construction material, followed closely by structural steel.

Approximately 50% of building designs are in reinforced concrete, with a further 1/3 of building

designs using structural steelwork. Only 5% of designers use either timber post & beam or cross

laminated timber (CLT) construction in the majority of their building projects, as such the use of

larger structural timber elements seems to be limited to a small number of specialist structural

designers.

Figure 4. Buildings designed using the following % of construction material types?

Combustibility: The combustibility of timber and bio-based building materials shows up as a

definite concern for designers, with 62% of designers stating they are either concerned or very

concerned about the combustibility of both structural timber elements, and exposed combustible

wall and ceiling linings. (See Figure 5). On a positive note only 1/3 of those showing a concern are

stating that they are very concerned. Approximately 20% of building designs either incorporate

combustible facades or combustible internal linings to buildings. The survey suggests that

designers in Croatia, Finland, Germany, Slovakia, and Spain may be more likely to use timber or

bio-based combustible materials in their building facades.

0

10

20

30

40What % of

buildings you

design using

timber

structural

elements are to

Eurocode 5 ?

0

20

40

60 Do you believe

the current

Timber

Eurocode (EN

1995) to be an

improvement

compared to

older standards?

0

20

40

60

80

0 to 5% 5 to 10% 10 to

30%

30 to

50%

> 50%

using structural timber

post & beams?

using Cross laminated

Timber (CLT)?

using structural steel?

using reinforced

concrete?

Page 69: Book of abstracts of COST FP 1404 MC and WG meeting Action FP1404 Fire Safe Use of Bio-Based Building Products Book of abstracts of COST FP 1404 MC and WG meeting: ”Dissemination,

64

Figure 5. Combustibility Concerns. Figure 6. % Combustible Facades & Linings

Sprinkler or Deluge Protection: The support for sprinkler protection follows an approximate bell

curve, with the greatest number of designers being in favour of its use. (See Figure 7 below).

There seems to be particular concern about the use of sprinkler protection to combustible

facades, possibly due to potential adverse weather effects, such as freezing of water within the

pipework systems, or strong winds blowing the water spray away from the area that requires

protection. Sprinklers like any other active system is never as certain as a passive system, as a

local explosion may render an entire system inoperable.

Figure 7. Sprinkler/Deluge protection to Combustibles

Fire Retardant Treatments & Impregnations: Almost 60% of designers are in favour of fire

retardant treatments and impregnations, while just over 20% disagree with their use. This

concern may be due to the relatively thin coating and the shallow depth of impregnation, thus

affecting lining properties more than duration of fire resistance. Furthermore coatings may get

damaged or painted over during their lifetime and their effectiveness could then become

compromised. (See Figure 8 below).

0

10

20

30

40

50 Does the combustible

nature of timber/bio-

based structural

elements under fire

conditions concern

you?

Does exposed

timber/bio-based

ceilings and walls

under fire conditions

concern you?0

10

20

30

40

50

0 -

10%

10 -

20%

20 -

30%

30 -

40%

>

40%

What % of buildings

you design have

Combustible

Facades, using

timber cladding or

bio-based materials

?

What % of buildings

you design have

Combustible wall &

ceiling linings, using

timber cladding or

bio-based materials

?

0

20

40

60

Strongly in

Favour

In Favour Neutral Disagree Strongly

Disagree

Would you be in favour of sprinkler/deluge fire

protection systems to protect external combustible

facades?

Would you be in favour of sprinkler/deluge fire

protection systems to protect internal combustible

linings?

Would you be in favour of sprinkler/deluge fire

protection systems to protect combustible load

bearing structures?

Page 70: Book of abstracts of COST FP 1404 MC and WG meeting Action FP1404 Fire Safe Use of Bio-Based Building Products Book of abstracts of COST FP 1404 MC and WG meeting: ”Dissemination,

65

Figure 8. Fire Retardant Treatments and Impregnations. Figure 9. 3rd

Party Design Review

3rd

Party Design Review: 71% of designers are in favour of a 3rd party review of timber designs,

with only 14% not being in favour. (See Figure 9 above). This strong opinion on the need for a 3rd

party review may suggest a lack of familiarity with the design of building elements composed of

timber or bio-based materials.

Conclusions & Recommendations: Designers in general see the sustainable benefits of using

timber and bio-based materials in buildings. However there appears to be concerns about the

combustibility of these materials, a lack of familiarity with their design, and this combined with a

potentially higher construction cost, which may be more weather dependant on site, leads to a

cautious approach for building designers as they consider moving away from reinforced concrete,

structural steel, and masonry. There is a general acceptance that sprinklers or surface coatings

and impregnations may help to alleviate some concerns. As the main driver is sustainability,

together with the visual attractiveness of timber and other bio-based materials, there is rarely an

economic incentive to produce timber buildings. The low level of Post & Beam or CLT construction

leads to an unfamiliarity with design using these materials, and this in turn leads to many building

contractors unsure of building using these methods. One possibility which may to encourage the

use of timber and bio-based materials, is the creation of easy to use guidelines for simpler

elements of construction using well thought out detailing, both from a fire safety aspect and from

a durability point of view. If designers used timber more regularly thus seeing its visual benefits,

then they may become more familiar with its design, and building contractors would in turn

follow their lead. As all members of the construction industry become more familiar with the use

of these materials, then its advantages should become more apparent.

References

EN 1995-1-1, 2004. Eurocode 5: Design of timber structures - Part 1-1: General - Common rules

and rules for buildings.

01020304050 Would you be in favour of

fire retarding coatings

being used to improve the

suitability of bio-based

wall & ceiling linings?

Would you be in favour of

fire retarding

impregnations being used

to improve the fire

resistance of bio-based

materials?

0102030405060

Would you be in

favour of a 3rd

party review of all

building designs

using timber/bio-

based primary

structural

elements ?

Page 71: Book of abstracts of COST FP 1404 MC and WG meeting Action FP1404 Fire Safe Use of Bio-Based Building Products Book of abstracts of COST FP 1404 MC and WG meeting: ”Dissemination,

66

EN 1995-1-2, 2004. Eurocode 5: Design of timber structures - Part 1-2: General – Structural fire

design.

Fan M., Fu F. 2017. Advanced High Strength Natural Fibre Composites in Construction, Woodhead

Publishing Series in Composites Science and engineering: Number:74, 557 pages.

Haroglu, H. 2009. Investigating the structural frame decision making process, Ph.D. thesis,

Loughborough University

Lawrence, M. 2014. The use of bio-based materials to reduce the environmental impact of

construction. In: International Congress on Materials and Structural Stability, 27-30 November

2013, Rabat, Morocco.

Lawrence, M. 2015. Reducing the Environmental Impact of Construction by Using Renewable

Materials, Journal of Renewable Materials 3, 163-174.

Page 72: Book of abstracts of COST FP 1404 MC and WG meeting Action FP1404 Fire Safe Use of Bio-Based Building Products Book of abstracts of COST FP 1404 MC and WG meeting: ”Dissemination,

67

Regulators’ Views on Bio-based Materials in Buildings.

Andrew Macilwraith1, Maria Pilar Giraldo2, Kathinka Leikanger Friquin3, & Ayfer

Donmez Cavdar 4.

1 Cork Institute of Technology, Rossa Avenue, Bishopstown, Cork, Ireland,

[email protected].

2 Forest Sciences Centre of Catalonia-INCAFUST, Av. Dr. Maranón 44, Barcelona, Spain ,

[email protected]

3 SINTEF Building and Infrastructure, Høgskoleringen 7b, Sluppen, 7465 Trondheim, Norway,

[email protected]

4 Faculty of Architecture, Karadeniz Technical University, 61080, Trabzon, Turkey.

[email protected]

Abstract

This investigation evaluates regulators’ opinions of construction using bio-based materials and

timber, primarily across Europe in terms of; sustainability, Eurocode 5 (EN 1995), construction

materials, combustibility, sprinkler or deluge protection, and fire retardant treatments or

impregnations. It aims to provide an indication of regulators’ views on the use of bio-based

materials and timber in buildings, using Lime Survey. This survey indicates that regulators are

generally aware of the sustainability benefits of these materials, however they are concerned

about the combustibility of these materials. There is a certain level of guarded acceptance in

relation to the use sprinklers, and surface coatings or impregnations, with a preference for

impregnations over surface coatings.

Keywords: Bio-based, timber, designers, buildings, opinions

Introduction:

Regulators, and fire officers, are required to certify larger building designs in many countries and

they tend to rely on prescriptive codes and standards when examining these designs (Meacham et

al. 2016). In many cases their standards require certain building elements to be non- combustible,

and this prescriptive requirement may mean that a fire engineering solution must be prepared by

the designer and submitted to the regulatory authority (Brannigan and Smidts 1999, Lo and Yuen

1999, Lataille 2002, Lo et al. 2002). This places additional workload on both the designer and the

regulator, and also additional costs onto the developer. This system varies between countries,

Page 73: Book of abstracts of COST FP 1404 MC and WG meeting Action FP1404 Fire Safe Use of Bio-Based Building Products Book of abstracts of COST FP 1404 MC and WG meeting: ”Dissemination,

68

and this regulator survey sets out to determine the underlying opinions of regulators and fire

officers, regarding the use of timber and bio-based materials in buildings.

A short 16 question online survey using ‘Lime survey’ was created to determine regulators views

on the use of timber and other bio-based materials in buildings. This questionnaire encompassed

concepts such as; sustainability, EN 1995 (Eurocode 5), construction materials, sprinklers,

coatings, impregnations, and a 3rd party review. Responses were received from 121 regulators

mainly from Europe. There was an increased response from Ireland of 34 respondents, and this

should be noted when analysing the results. Some regulators chose not to answer a number of

questions, and the percentages have been adjusted accordingly to take this into account.

Importance of Sustainability: The majority of regulators were neutral, or did not give an answer,

regarding their view on the sustainability of timber and bio-based materials, the remainder

generally agreed that these materials are more sustainable. When asked whether they would be

in favour of an increase in the use of timber and bio-based materials in buildings, they gave a

more positive response with 1/3 being in favour. (See Figure 1 below).

Figure 1. Sustainability & Use of Timber & Bio-based Materials in Buildings

Lack of Familiarity with Eurocode 5 (EN 1995): Over 90% of the regulators surveyed agreed, or

strongly agreed, that they are not familiar with Eurocode 5 (EN 1995, with the remaining 10%

being neutral. (See Figure 2 below). This lack of familiarity with this key timber structural design

document by fire officers and regulators suggests a possible lack of awareness of timber fire

engineering design principles and the current state of the art.

0

20

40

60

Strongly in

Favour

In Favour Neutral Disagree Strongly

Disagree

Is it your view that bio-based

materials are more sustainable

than other building products?

Are you in favour of increasing

the use of timber and bio-based

materials in buildings?

Page 74: Book of abstracts of COST FP 1404 MC and WG meeting Action FP1404 Fire Safe Use of Bio-Based Building Products Book of abstracts of COST FP 1404 MC and WG meeting: ”Dissemination,

69

Figure 2. Lack of Familiarity with Eurocode 5 (EN 1995) [1,2]

Construction Materials: The majority of regulators rarely if ever examine timber Post and Beam

or Cross laminated Timber (CLT) structures, as they only occur in approximately 8% of

developments certified or inspected. Reinforced concrete construction would account for over

50% of building projects, while structural steel would be used in approximately 30% of structures.

The remaining structural elements would primarily be masonry type developments. (See Figure 3

below).

Figure 3. Construction Materials. Figure 4. % Board protection to Timber

Board Protection to Timber Structural Elements: There appears to be a large variation in the use

of board protection, primarily using gypsum based boards. Over 20% of regulators have

plasterboard protection in the majority of the timber buildings that they examine or certify. At the

other end of the scale almost 40% of regulators do not see board protection, suggesting that

exposed timber may be present in these building projects. The remaining 40% have a range of

values, examining buildings with both exposed and protected timber structural elements. (See

Figure 4 above).

0

50

100

Strongly

Agree

Agree Neutral Disagree Strongly

Disagree

Would you agree that many

Fire Officers/Regulators

would not be familiar with

Eurocode 5?

0

20

40

60

80

100

0 -

5%

5 -

10%

10%

to

30%

30 -

50%

>

50%

% in structural

timber post &

beams?

% in Cross

laminated Timber

(CLT)?

% in structural

steel?

% in reinforced

concrete?

05

1015202530354045

<2

0%

20

to

40

%

40

to

60

%

60

to

80

%

>8

0%

What % of

buildings

use board

protection

over

timber

structural

members?

Page 75: Book of abstracts of COST FP 1404 MC and WG meeting Action FP1404 Fire Safe Use of Bio-Based Building Products Book of abstracts of COST FP 1404 MC and WG meeting: ”Dissemination,

70

Combustibility: The main concern of regulators is the combustibility of timber and bio-based

materials when used in buildings. 85% of responses indicated a concern in relation to this issue.

(See Figure 5 below). The highest level of concern being indicated by regulators in Belgium,

France, Germany, Ireland, Poland, & Turkey. This current widespread concern by regulators is

certainly a deterrent to the use of timber and bio-based materials in the construction industry.

Figure 6 shows the breakdown of % of combustible facades and internal linings found in buildings

which have been inspected or certified by regulators. This indicates that many regulators, almost

30%, do not allow combustible facades or internal linings in the majority of the buildings that they

certify or inspect. Examining the overall responses, approximately 15% of buildings have

combustible facades, with approximately 17% of projects having combustible internal linings.

Figure 5. Combustibility Concerns. Figure 6. % Combustible Facades & Linings

Sprinkler Protection: There is a general level of approval for the use of sprinkler protection by

regulators (See Figure 7 below), however there are 20% of regulators who disagree with their use.

This concern may be due to the fact that any active system may not be as reliable as a passive

system, particularly if the passive system has non-combustible elements. There was a higher level

of agreement with internal sprinklers, than external ones, possible due to the effects of weather

on their operation.

010203040506070 Does the

combustible nature

of timber/bio-based

structural elements

under fire conditions

concern you?

Does exposed

timber/bio-based

ceilings and walls

under fire conditions

concern you?

0

10

20

30

40

50

0 -

10%

10 -

20%

20 -

30%

30 -

40%

>

40%

% of buildings with

Combustible

Facades, using

timber cladding or

bio-based

materials ?

% of buildings with

Combustible wall

& ceiling linings,

using timber

cladding or bio-

based materials ?

Page 76: Book of abstracts of COST FP 1404 MC and WG meeting Action FP1404 Fire Safe Use of Bio-Based Building Products Book of abstracts of COST FP 1404 MC and WG meeting: ”Dissemination,

71

Figure 7. Sprinkler protection to Combustible Elements

Fire Retardant Treatments & Impregnations: Almost 60% of designers are in favour of fire

retardant treatments and impregnations, while just over 20% disagreeing with their use. This

concern may be due to the relatively thin coating and the shallow depth of impregnation, thus

affecting lining properties more than duration of fire resistance. Furthermore coatings may get

damaged or painted over during their lifetime and their effectiveness could then become

compromised. (See Figure 8 below).

Figure 8. Fire Retardant Treatments and Impregnations. Figure 9. 3rd

Party Design Review

3rd

Party Design Review: Most regulators, 72% are either in favour, or strongly in favour of a 3rd

party review of projects with structural timber elements. (See Figure 9 above). The countries that

appear to be most in favour of such a review are; Belgium, Greece, Ireland, & Turkey.

Conclusions & Recommendations: Regulators across Europe appear to be significantly concerned

about the combustibility of timber and bio-based materials when used in buildings. However this

does not seem to translate into the provision of protective plasterboard protection in all cases,

with some regulators allowing exposed timber. The combustibility of structural elements, internal

linings, and facades are all a cause of concern to regulators. The extreme lack of familiarity with

0

10

20

30

40

50

Strongly in

Favour

In Favour Neutral Disagree Strongly

Disagree

Would you be in favour of sprinkler/deluge fire

protection systems to protect external combustible

facades?

Would you be in favour of sprinkler/deluge fire

protection systems to protect internal combustible

linings?

Would you be in favour of sprinkler/deluge fire

protection systems to protect combustible load

bearing structures?

0102030405060 Would you be in favour of

fire retarding coatings

being used to improve the

suitability of bio-based wall

& ceiling linings?

Would you be in favour of

fire retarding

impregnations being used

to improve the fire

resistance of bio-based

materials?

0

10

20

30

40

50

Would you be

in favour of a

3rd party

review of all

building

designs using

timber/bio-

based primary

structural

elements ?

Page 77: Book of abstracts of COST FP 1404 MC and WG meeting Action FP1404 Fire Safe Use of Bio-Based Building Products Book of abstracts of COST FP 1404 MC and WG meeting: ”Dissemination,

72

Eurocode 5 among regulators is alarming and suggests that a campaign aimed at educating

regulators in the use and fire safe design of timber may be required.

References

Brannigan, V., Smidts, C., 1999. Performance Based Fire Safety Regulation under Intentional

Uncertainty, Fire and Materials. 23 (6) 341-347.

EN 1995-1-1, 2004. Eurocode 5: Design of timber structures - Part 1-1: General - Common

rules and rules for buildings.

EN 1995-1-2, 2004. Eurocode 5: Design of timber structures - Part 1-2: General – Structural

fire design.

Lataille J. 2002, Fire Protection Engineering in Building Design, Imprint: Butterworth-

Heinemann, 133 pages.

Lo S., Lam K., Yuen K. 2002. An Investigation on the Building Officials' Perception for the Use

of Performance-Based Fire Engineering Approach in Building Design, Fire Technology, 38:

271- 286.

Lo S.M., Yuen K.K., 1999. Views of Building Professionals on the Implementation Aspect of Fire

Safety Engineering Approach in Building Design—A Preliminary View. International Journal on

Engineering Performance-based Fire Code, 1 (3), 129–133.

Meacham B. J., Charters D., Johnson P., Salisbury M. 2016. Building Fire Risk Analysis, Chapter

75, SFPE Handbook of Fire Protection Engineering, Eds. M. J. Hurley, D. T. Gottuk, J. R. Hall Jr.,

K. Harada, E.D. Kuligowski, M. Puchovsky, J.L. Torero, J. M. Watts Jr., C. J. Wieczorek , 2941-

2991.

Page 78: Book of abstracts of COST FP 1404 MC and WG meeting Action FP1404 Fire Safe Use of Bio-Based Building Products Book of abstracts of COST FP 1404 MC and WG meeting: ”Dissemination,

73

Working Group 4

Dissemination

Page 79: Book of abstracts of COST FP 1404 MC and WG meeting Action FP1404 Fire Safe Use of Bio-Based Building Products Book of abstracts of COST FP 1404 MC and WG meeting: ”Dissemination,

74

First COST Action FP1404 Training School – Fire Safe Use of

Bio-Based Materials – University of Edinburgh, UK

Rory Hadden, Luke Bisby*, Felix Wiesner, Nikolai Gerasimov, Alastair Bartlett

School of Engineering, University of Edinburgh, UK,

* [email protected]

Keywords: Training, CLT, laminated bamboo, heat transfer, fire dynamics, structural engineering

The first COST Action FP 1404 training school was held at the BRE Centre for Fire Safety

Engineering, School of Engineering, University of Edinburgh, from 3-5 October 2016. The Training

school was specifically designed to give participants a detailed and fundamental view of some of

the fire safety problems associated with bio-based building materials. Practical laboratory

experiments (Figures 1 and 2), combined with lectures from international experts and classroom

work, explored concepts of heat transfer, fire dynamics, material response, and structural fire

engineering. The course was delivered by Dr Rory Hadden (Edinburgh), Prof Luke Bisby

(Edinburgh), Dr Guillermo Rein (Imperial College London), Dr Dionysiοs Colitis (National Technical

University of Athens), and Prof Ulf Wickstrom (Lulea University of Technology).

Figure 1. Training School participants observe a compartment fire dynamics

experiment on a cross-laminated timber compartment with exposed internal timber

surfaces.

The lecture topics included: Compartment fire dynamics; pyrolysis, ignition and burning of wood;

structural fire engineering and modelling; real fire exposures; numerical modelling of

timber structures’ response in fire; and heat transfer [1] and pyrolysis modelling. The final day of

the workshop consisted of students’ presentations on their own research projects, and reflections

on these in light of the experiences obtained during the training school. This first COST Action

FP1404 Training School was, in the opinions of the organisers, highly effective and useful; thanks

Page 80: Book of abstracts of COST FP 1404 MC and WG meeting Action FP1404 Fire Safe Use of Bio-Based Building Products Book of abstracts of COST FP 1404 MC and WG meeting: ”Dissemination,

75

to all the enthusiastic students and interesting, engaging lecturers. Looking forward to the next

one!

Figure 2. Training School participants observe a structural fire experiment on a loaded

laminated bamboo beam.

Acknowledgments

The authors would like to acknowledge the valuable contributions of the Training School

instructors and participants.

References

[1] Wickstrom U. 2016. Temperature Calculation in Fire Safety Engineering, Springer, 1st

ed. 2016, 243 p., ISBN 978-3-319-30172-3

Page 81: Book of abstracts of COST FP 1404 MC and WG meeting Action FP1404 Fire Safe Use of Bio-Based Building Products Book of abstracts of COST FP 1404 MC and WG meeting: ”Dissemination,

76

Notes

Page 82: Book of abstracts of COST FP 1404 MC and WG meeting Action FP1404 Fire Safe Use of Bio-Based Building Products Book of abstracts of COST FP 1404 MC and WG meeting: ”Dissemination,

77

Notes

Page 83: Book of abstracts of COST FP 1404 MC and WG meeting Action FP1404 Fire Safe Use of Bio-Based Building Products Book of abstracts of COST FP 1404 MC and WG meeting: ”Dissemination,

78

Notes