bomba de desplazamiento positivo
DESCRIPTION
Bomba de desplazamiento positivoTRANSCRIPT
DATOS DEL LABORATORIO:N = 600 RPM
PuntoP2barP1barHmmHgVVIA
1002101154.3
2102051174.6
3201851195.1
4301601215.7
5401401236.8
N = 560 RPM
PuntoP2barP1barHmmHgVVIA
1001851074.3
2101801104.6
3201601125.1
4301451135.7
5401301156.3
N = 500 RPM
PuntoP2barP1barHmmHgVVIA
100155974.3
210145994.5
3201301015
4301101045.8
540951066.7
N = 460 RPM
PuntoP2barP1barHmmHgVVIA
100135904.2
210125924.5
320110945.0
43090975.7
54085996.7
CLCULOS Y RESULTADOSN = 600 RPM
PuntoHBmQm3/sPhWPelecW%
108.2541*10-40494.50.000
210.338.1553*10-482.643538.215.355
320.667.7473*10-4157.017606.925.872
430.997.2048*10-4219.034689.731.757
541.326.7395*10-4273.184836.432.661
Altura de la Bomba VS Caudal:
Potencia hidrulica VS Caudal:
Potencia elctrica VS Caudal:
Eficiencia VS Caudal:
N = 560 RPM
PuntoHBmQm3/sPhWPelecW%
107.7473*10-40.000460.10.000
210.337.6418*10-477.44050615.304
320.667.2048*10-4146.023571.225.564
430.996.8588*10-4208.515644.132.373
541.326.4943*10-4263.247724.536.335
Altura de la Bomba VS Caudal:
Potencia hidrulica VS Caudal:
Potencia elctrica VS Caudal:
Eficiencia VS Caudal:
N = 500 RPM
PuntoHBmQm3/sPhWPelecW%
107.0913*10-40.000417.10.000
210.336.8588*10-469.505445.515.602
320.666.4943*10-4131.62350526.064
430.995.9739*10-4181.614603.230.108
541.325.5517*10-4225.037710.231.686
N = 460 RPM
PuntoHBmQm3/sPhWPelecW%
106.618*10-40.0003780.000
210.336.3682*10-464.53441415.588
320.665.9739*10-4121.07647025.761
430.995.4036*10-4164.276552.929.712
541.325.2514*10-4212.863663.332.092