bni eip-306-000-z010 bni eip-306-100-z010 -...

22
BNI EIP-306-000-Z010 BNI EIP-306-100-Z010 IP67 Module,16 Inputs and 16 Outputs BNI EIP-308-100-Z010 IP67 Module, 32 In-/Outputs User’s Guide

Upload: duongtram

Post on 25-Jun-2018

305 views

Category:

Documents


6 download

TRANSCRIPT

Page 1: BNI EIP-306-000-Z010 BNI EIP-306-100-Z010 - Balluffassets.balluff.com/WebBinary1/DOK_887581_01_000.pdf · BNI EIP-306-000-Z010 BNI EIP-306-100-Z010 ... BNI EIP-306 -100.. BNI EIP-306

BNI EIP-306-000-Z010

BNI EIP-306-100-Z010

IP67 Module,16 Inputs and 16 Outputs

BNI EIP-308-100-Z010

IP67 Module, 32 In-/Outputs

User’s Guide

Page 2: BNI EIP-306-000-Z010 BNI EIP-306-100-Z010 - Balluffassets.balluff.com/WebBinary1/DOK_887581_01_000.pdf · BNI EIP-306-000-Z010 BNI EIP-306-100-Z010 ... BNI EIP-306 -100.. BNI EIP-306

www.balluff.com 1

Content

1 Notes 3 1.1. About this guide 3 1.2. Structure of the guide 3 1.3. Typographical Conventions 3

Enumerations 3 Actions 3 Syntax 3 Cross-references 3 Symbols 3

1.4. Abbreviations 3

2 Safety 4 2.1. Intended use 4 2.2. General safety notes 4 2.3. Meaning of the warnings 4

3 Getting Started 5 3.1. Module Overview Standard BNI EIP-306-000… 5 3.2. Module Overview Display BNI EIP-306-100.. 6 3.3. Module Overview BNI EIP-308-100-Z010 7 3.4. Mechanical connection 8 3.5. Electrical connection 8

Power Supply 8 Grounding 8 Ethernet IP Interface 8 I/O-Port 9

4 Technical data 10 4.1. Dimensions 10 4.2. Mechanical data 10 4.3. Operating conditions 10 4.4. Electrical data 10 4.5. Ethernet 11 4.6. Function indicators 11

Port 11

5 Integration 12 5.1. Integration into RSLogix 12

6 Process Data 14 6.1. Process Data Input BNI EIP-306-x00-… 14 6.2. Process Data Output BNI EIP-306-x00-… 14 6.3. Process Data Inputs BNI EIP-308-…. 15 6.4. Process Data Outputs BNI EIP-308-…. 15

7 Display 16 7.1. General 16

Address Defaults 16 Controls and Visualization 16 Display Information 16 Symbols 17

7.2. Startup 17 7.3. Main Menu 17 7.4. Octet scrolling 17 7.5. IP Configuration 18 7.6. General Information 18

8 Webserver 19 8.1. General 19 8.2. Home 19 8.3. Diagnostic Process 19

Page 3: BNI EIP-306-000-Z010 BNI EIP-306-100-Z010 - Balluffassets.balluff.com/WebBinary1/DOK_887581_01_000.pdf · BNI EIP-306-000-Z010 BNI EIP-306-100-Z010 ... BNI EIP-306 -100.. BNI EIP-306

Balluff Network Interface EtherNet/IP™, BNI EIP-302-105-Z015

www.balluff.com 2

8.4. Diagnostic Module 19 8.5. Configurations 19

9 Appendix 20 9.1. Product Name 20 9.2. Order Code 20 9.3. Included Material 20

Page 4: BNI EIP-306-000-Z010 BNI EIP-306-100-Z010 - Balluffassets.balluff.com/WebBinary1/DOK_887581_01_000.pdf · BNI EIP-306-000-Z010 BNI EIP-306-100-Z010 ... BNI EIP-306 -100.. BNI EIP-306

www.balluff.com 3

1 Notes

1.1. About this guide The BNI EIP-… serves as a decentralized input and output module for connecting to an EtherNet/IP™ network.

1.2. Structure of the

guide The guide is organized so that the chapters build on one another.

Chapter 2: Basic safety information. Chapter 3: Getting started Chapter 4: Technical data Chapter 5: Integration …..

1.3. Typographical

Conventions The following typographical conventions are used in this Guide.

Enumerations Enumerations are shown in list form with bullet points.

Entry 1,

Entry 2.

Actions Action instructions are indicated by a preceding triangle. The result of an action is indicated by an arrow.

Action instruction 1, Action result. Action instruction 2.

Procedures can also be shown as numbers in brackets. Step no. 1 Step no. 2

Syntax Numbers:

Decimal numbers are shown without additional indicators (e.g. 123), Hexadecimal numbers are shown with the additional indicator hex (e.g. 00hex) or with the prefix “0x” (e.g. 0x00)

Cross-references Cross references indicate where additional information on the topic can be found (see

chapter 4 ”Technical Data”).

Symbols Note tip

This symbol indicates general notes.

Note!

This symbol indicates a security notice which most be observed.

1.4. Abbreviations BNI Balluff Network Interface

I Standard input port EIP EtherNet/IP™ EMC Electromagnetic Compatibility FE Function ground O Standard output port

Page 5: BNI EIP-306-000-Z010 BNI EIP-306-100-Z010 - Balluffassets.balluff.com/WebBinary1/DOK_887581_01_000.pdf · BNI EIP-306-000-Z010 BNI EIP-306-100-Z010 ... BNI EIP-306 -100.. BNI EIP-306

Balluff Network Interface EtherNet/IP™

www.balluff.com 4

2 Safety

2.1. Intended use

This guide describes The BNI EIP-… serves as a decentralized input and output module for connecting to an EtherNet/IP™ network.

2.2. General safety

notes Installation and startup are to be performed only by trained specialists. Any damage

resulting from unauthorized manipulation or improper use voids the manufacturer’s guarantee and warranty. The device is in accordance with EMC Class A. Such equipment may generate RF noise. The operator must take precautionary measures accordingly. The device must be powered only using an approved power supply (see chapter 4 “Technical data”). Only approved cable may be used. Operating and testing

The operator is responsible for observing local prevailing safety regulations. When defects and non-clearable faults in the device occur, take it out of service and secure against unauthorized use. Approved use in ensured only when the housing is fully installed.

2.3. Meaning of the warnings

Note!

The pictogram used with word ”Caution“ warns of a possible hazardous situation affecting the health of persons or equipment damage. Ignoring these warnings can result in injury or equipment damage.

Always observe the described measures for preventing this danger.

Page 6: BNI EIP-306-000-Z010 BNI EIP-306-100-Z010 - Balluffassets.balluff.com/WebBinary1/DOK_887581_01_000.pdf · BNI EIP-306-000-Z010 BNI EIP-306-100-Z010 ... BNI EIP-306 -100.. BNI EIP-306

www.balluff.com 5

3 Getting Started

3.1. Module Overview Standard BNI EIP-306-000…

BNI EIP-306-000-Z010

1 Mounting hole 2 IPAP, Programming Interface 3 Status LED 4 Port 08 / 09 Output 5 Pin/Port LED: Signal status 6 Port 10 / 11 Output 7 Port 12 / 13 Output 8 Port 14 / 15 Output 9 Port 08 / 09 Input 10 Port 10 / 11 Input 11 Port 12 / 13 Input 12 Port 14 / 15 Input

13 Port 06 / 07 Input 14 Port 04 / 05 Input 15 Port 02 / 03 Input 16 Port 00 / 01 Input 17 Port 06 / 07 Output 18 Port 04 / 05 Output 19 Port 02 / 03 Output 20 Port 00 / 01 Output 21 Power Supply Port 22 Label 23 EtherNet/IP™ port 24 Grounding connection

1

8

7

6

4

2

3

13

14

15

16

17

18

19

20

21

22

9

10

11

12

23

24

5

Page 7: BNI EIP-306-000-Z010 BNI EIP-306-100-Z010 - Balluffassets.balluff.com/WebBinary1/DOK_887581_01_000.pdf · BNI EIP-306-000-Z010 BNI EIP-306-100-Z010 ... BNI EIP-306 -100.. BNI EIP-306

Balluff Network Interface EtherNet/IP™

www.balluff.com 6

3 Getting Started

3.2. Module Overview Display BNI EIP-306-100..

BNI EIP-306-100-Z010

1 Mounting hole 2 IPAP, Programming Interface 3 Display 4 Status LED: Communication / Module 5 Port 08 / 09 Output 6 Pin/Port LED: Signal status 7 Port 10 / 11 Output 8 Port 12 / 13 Output 9 Port 14 / 15 Output 10 Port 08 / 09 Input 11 Port 10 / 11 Input 12 Port 12 / 13 Input 13 Port 14 / 15 Input

14 Port 06 / 07 Input 15 Port 04 / 05 Input 16 Port 02 / 03 Input 17 Port 00 / 01 Input 18 Port 06 / 07 Output 19 Port 04 / 05 Output 20 Port 02 / 03 Output 21 Port 00 / 01 Output 22 Power Supply Port 23 Label 24 EtherNet/IP™ port 25 Grounding connection

14

15

1666

17

18

19

20

21

23

22

24

25 1

2

3

4

5

6

7

8

9

10

11

12

13

Page 8: BNI EIP-306-000-Z010 BNI EIP-306-100-Z010 - Balluffassets.balluff.com/WebBinary1/DOK_887581_01_000.pdf · BNI EIP-306-000-Z010 BNI EIP-306-100-Z010 ... BNI EIP-306 -100.. BNI EIP-306

www.balluff.com 7

3 Getting Started

3.3. Module Overview BNI EIP-308-100-Z010

BNI EIP-308-000-Z010

1 Mounting hole 2 IPAP, Programming Interface 3 Display 4 Status LED: Communication / Module 5 Port 08 / 09 In-/ Output 6 Port 10 / 11 In-/ Output 7 Port 12 / 13 In-/ Output 8 Port 14 / 15 In-/ Output 9 Port 24 / 25 In-/ Output 10 Port 26 / 27 In-/ Output 11 Port 28 / 29 In-/ Output 12 Port 30 / 31 In-/ Output 13 Port 22 / 23 In-/ Output

14 Port 20 / 21 In-/ Output 15 Port 18 / 19 In-/ Output 16 Port 16 / 17 In-/ Output 17 Port 06 / 07 In-/ Output 18 Port 04 / 05 In-/ Output 19 Port 02 / 03 In-/ Output 20 Pin/Port LED : Signal status 21 Port 00 / 01 In-/ Output 22 Power Supply Port 23 Label 24 EtherNet/IP™ port 25 Grounding connection

14

15

18

19

20

22

13

16

17

21

24

25

23

4

5

3

2

1

6

7

8

9

10

11

12

Page 9: BNI EIP-306-000-Z010 BNI EIP-306-100-Z010 - Balluffassets.balluff.com/WebBinary1/DOK_887581_01_000.pdf · BNI EIP-306-000-Z010 BNI EIP-306-100-Z010 ... BNI EIP-306 -100.. BNI EIP-306

Balluff Network Interface EtherNet/IP™

www.balluff.com 8

3 Getting Started

3.4. Mechanical connection

The module is attached using 2 M6 screws and 2 washers. Isolation pad as accessory available

3.5. Electrical

connection

Power Supply

Pin Function Description

1 +24 V Output Power

2 +24 V Input Power

3 0 V Input Power Common GND

4 0 V Output Power Common GND

Note tip

Provide sensor/bus power and actuator power from separate power sources if possible. Total current <9A. The total current of all modules may not exceed 9A even when daisy chaining the actuator supply.

Grounding

Note tip

The FE connection from the housing to the machine must be low-impedance and kept as short as possible.

Ethernet IP Interface

M12, D-coded, female

Pin Function

1 Tx+

2 Rx+

3 Tx-

4 Rx-

Page 10: BNI EIP-306-000-Z010 BNI EIP-306-100-Z010 - Balluffassets.balluff.com/WebBinary1/DOK_887581_01_000.pdf · BNI EIP-306-000-Z010 BNI EIP-306-100-Z010 ... BNI EIP-306 -100.. BNI EIP-306

www.balluff.com 9

3 Getting Started

I/O-Port M12, A-coded, female

PIN

Function

Input Output In-/Output

1 +24V 0.2A

n.c. +24V 0.2A

2 Input 1 Output 1 In-/Output

3 0V 0V 0V

4 Input 2 Output 2 In-/Output

5 FE FE FE

Note!

For the digital sensor inputs follow the input guideline per EN61131-2, type 2.

Note!

Each output serves a maximum current of 2 amperes. Total current of the module has to be lower than 9 amperes.

Note!

Unused I/O port socket must be fitted with cover caps to ensure IP67 protection rating.

Page 11: BNI EIP-306-000-Z010 BNI EIP-306-100-Z010 - Balluffassets.balluff.com/WebBinary1/DOK_887581_01_000.pdf · BNI EIP-306-000-Z010 BNI EIP-306-100-Z010 ... BNI EIP-306 -100.. BNI EIP-306

Balluff Network Interface EtherNet/IP™

www.balluff.com 10

4 Technical data

4.1. Dimensions

4.2. Mechanical data Housing material Die case zinc, matt nickel plated

Enclosure rating per IEC 60529 IP 67 (only when plugged-in and threaded-in)

Supply voltage 7/8” 4-pin male

Input ports / Output ports M12, A-coded (8 x female)

Dimensions (W x H x D in mm) 68 x 334 x 32.4

Mounting type 2-hole screw mount

Ground strap attachment M4

Weight Approx. 900 g

4.3. Operating conditions

Operating temperature Ta

Storage temperature -5 °C ... 55 °C -25 C ... 75 °C

EMC - EN 61000-4-2/3/4/5/6 - EN 55011

- Severity level 4A/3A/4B/2A/3A - Gr.1, CL. A

Shock/vibration EN 60068-2-6, EN 60068-2-27 EN 60068-2-29, EN 60068-2-64

4.4. Electrical data Supply voltage 18...30.2 V DC, per EN 61131-2

Ripple <1%

Input current at 24 V

Page 12: BNI EIP-306-000-Z010 BNI EIP-306-100-Z010 - Balluffassets.balluff.com/WebBinary1/DOK_887581_01_000.pdf · BNI EIP-306-000-Z010 BNI EIP-306-100-Z010 ... BNI EIP-306 -100.. BNI EIP-306

www.balluff.com 11

4 Technical data

4.5. Ethernet Ethernet IP port 1 x 10Base-/100Base-Tx

Connection for Ethernet IP port M12, D-coded, female

Cable types per IEEE 802.3 Shielded twisted pair min. STP CAT 5/ STP CAT 5e

Data transmission rate 10/100 Mbit/s

Max. cable length 100 m

Flow control Half Duplex/Full Duplex (IEEE 802.33x-Pause)

4.6. Function

indicators

LED Display Function

UA green Output power OK

red Low Output power (< 18V)

Mod

green flashing Wrong or no configuration on module

green Module operating

red flashing Fixed busclock is not possible

red-green flashing Initial sequence

Net

off Module got no IP address

green flashing Module got IP, but no connection could be established

green Connection established

red flashing Connection timeout

red-green flashing Initial sequence

100 off Bus clock: 10 Mbit/s

yellow Bus clock: 100 Mbit/s

US green Input power OK

red Low Input power (<18V)

LNK green Data transfer

Port Each Port has two two colour LED´s to indicate the I/O-States.

Display Function Description

off I/O-State State of the Input or Output Pin is 0

yellow I/O-State State of the Input or Output Pin is 1

red Short-circuit single LED: Short-circuit on dedicated Pin (only if this pin is used as an output) both LEDs: Short-circuit between Pin 1 and 3 or Short-circuit on both output pins

Status –LEDs: Modul status

Port/Pin LEDs: Status of the IO Link and I/O ports

Page 13: BNI EIP-306-000-Z010 BNI EIP-306-100-Z010 - Balluffassets.balluff.com/WebBinary1/DOK_887581_01_000.pdf · BNI EIP-306-000-Z010 BNI EIP-306-100-Z010 ... BNI EIP-306 -100.. BNI EIP-306

Balluff Network Interface EtherNet/IP™

www.balluff.com 12

5 Integration

5.1. Integration into RSLogix

(3) Start/Open RSLogix 5000 Project (4) Add EtherNet/IP Communication Module to the I/O Configuration (5) Right-Click I/O Configuration Folder and Choose “New Module

Page 14: BNI EIP-306-000-Z010 BNI EIP-306-100-Z010 - Balluffassets.balluff.com/WebBinary1/DOK_887581_01_000.pdf · BNI EIP-306-000-Z010 BNI EIP-306-100-Z010 ... BNI EIP-306 -100.. BNI EIP-306

www.balluff.com 13

5 Integration

(6) Choose Communication Module from List (7) Click “OK”

Configuration of the generic module for Balluff EtherNet/IP modules

(8) Name of the module

(9) Choose “Data-SINT” at „Comm Format

(10) Enter the IP address for the Balluff module (11) Entert the „Assembly Instance“ and the size of the inputs, outputs and the

configurations. (12) Click “OK”

Page 15: BNI EIP-306-000-Z010 BNI EIP-306-100-Z010 - Balluffassets.balluff.com/WebBinary1/DOK_887581_01_000.pdf · BNI EIP-306-000-Z010 BNI EIP-306-100-Z010 ... BNI EIP-306 -100.. BNI EIP-306

Balluff Network Interface EtherNet/IP™

www.balluff.com 14

6 Process Data

6.1. Process Data

Input BNI EIP-306-x00-…

By

te

Bit Description

7 6 5 4 3 2 1 0

0 I7 I6 I5 I4 I3 I2 I1 I0 Input data

1 I15 I14 I13 I12 I11 I10 I9 I8

2 S7 S6 S5 S4 S3 S2 S1 S0 Short circuit status

3 S15 S14 S13 S12 S11 S10 S9 S8

4 HS7 HS6 HS5 HS4 HS3 HS2 HS1 HS0 Output Handshake

5 HS15 HS14 HS13 HS12 HS11 HS10 HS9 HS8

6 OL23 OL22 OL21 OL20 OL19 OL18 OL17 OL16 Overload status

7 OL31 OL30 OL29 OL28 OL27 OL26 OL25 OL24

8 PS PA Power status PS: Sensor Power PA: Actor power

6.2. Process Data

Output BNI EIP-306-x00-…

Byte

Bit Description

7 6 5 4 3 2 1 0

0 O7 O6 O5 O4 O3 O2 O1 O0

Output data 1 O15 O14 O13 O12 O11 O10 O9 O8

2 R7 R6 R5 R4 R3 R2 R1 R0 Restart

3 R15 R14 R13 R12 R11 R10 R9 R8

4 YF YO RF RO

IPAP Control RO: red LED on RF: red LED flashing YO: yellow LED on YF: yellow LED flashing

5 PL GO RO

Display Control RO: red LED on GO: green LED on PL: PLC lock active

Page 16: BNI EIP-306-000-Z010 BNI EIP-306-100-Z010 - Balluffassets.balluff.com/WebBinary1/DOK_887581_01_000.pdf · BNI EIP-306-000-Z010 BNI EIP-306-100-Z010 ... BNI EIP-306 -100.. BNI EIP-306

www.balluff.com 15

6 Process Data

6.3. Process Data Inputs BNI EIP-308-….

By

te

Bit Description

7 6 5 4 3 2 1 0

0 I32 I34 I22 I24 I12 I14 I02 I04 Input data (and Feedback output) I04 Input on port 0 pin 4

1 I72 I74 I62 I64 I52 I54 I42 I44

2 I112 I114 I102 I104 I92 I94 I82 I84

3 I152 I154 I142 I144 I132 I134 I122 I124

4 S3 S2 S1 S0 Short circuit status 00hex no short circuit 03hex short circuit between Pin 1 and 3 on stated port

5 S7 S6 S5 S4

6 S11 S10 S9 S8

7 S15 S14 S13 S12

8 O32 O34 O22 O24 O12 O14 O02 O04 Overload status O04=1 Overload on port 0 pin 4

9 O72 O74 O62 O64 O52 O54 O42 O44

10 O112 O114 O102 O104 O92 O94 O82 O84

11 O152 O154 O142 O144 O132 O134 O122 O124

12 0 0 0 0 0 0 PS PA Power status PS: Sensor power PA: Actor power

6.4. Process Data

Outputs BNI EIP-308-….

Byte

Bit Description

7 6 5 4 3 2 1 0

0 O32 O34 O22 O24 O12 O14 O02 O04

Output data O04 Output on port 0 pin 4

1 O72 O74 O62 O64 O52 O54 O42 O44

2 O112 O114 O102 O104 O92 O94 O82 O84

3 O152 O154 O142 O144 O132 O134 O122 O124

4 R32 R34 R22 R24 R12 R14 R02 R04

Restart Restart output here after a detected overload

5 R72 R74 R62 R64 R52 R54 R42 R44

6 R112 R114 R102 R104 R92 R94 R82 R84

7 R152 R154 R142 R144 R132 R134 R122 R124

8 YF YO RF RO

IPAP Control RO: Red LED on RF: Red LED flashing YO: Yellow LED on YF: Yellow LED flashing

9 PL GO RO

Display Control RO: Red LED on GO: Green LED on PL: PLC lock active

Page 17: BNI EIP-306-000-Z010 BNI EIP-306-100-Z010 - Balluffassets.balluff.com/WebBinary1/DOK_887581_01_000.pdf · BNI EIP-306-000-Z010 BNI EIP-306-100-Z010 ... BNI EIP-306 -100.. BNI EIP-306

Balluff Network Interface EtherNet/IP™

www.balluff.com 16

7 Display

7.1. General With the implemented display, the address is set directly on the BNI EIP… devices. The following address types are implemented:

IP address

Subnet mask

Gateway address. Each address type consists of 4 octets. Additional the display shows information about the hard- and firmware revision. There is a lock function for the display which can be activated out of the control system. If the lock is set editing isn’t possible anymore (see Bit layout, chapter 8 „Appendix“).

Address Defaults IP Address: 169.254.1.1

Subnetmask: 255.255.255.0

Gatewayaddress: 0.0.0.0

Controls and Visualization

1 Display 2 Arrow-Key 3 Octet-Cursor

4 Address type cursor 5 Set-Key 6 LED

Display Information

IP: IP address SN: Subnet address GW: Gateway address

0: fourth octet 1: third octet 2: second octet 3: first octet

S ↑ IP

SN

GW

3 2 1 0

1

2

3 4

5

6

GW

IPIPI

0 1 2 3 Cursor for selecting octet

Cursor for selecting address type

SN

IP

Page 18: BNI EIP-306-000-Z010 BNI EIP-306-100-Z010 - Balluffassets.balluff.com/WebBinary1/DOK_887581_01_000.pdf · BNI EIP-306-000-Z010 BNI EIP-306-100-Z010 ... BNI EIP-306 -100.. BNI EIP-306

www.balluff.com 17

7 Display

Symbols There are some symbols used in the following flow-charts to describe the display-functionality:

7.2. Startup

Startup screen is shown for 2 seconds

7.3. Main Menu

Default view after startup: 4th Octet of IP address

First octet of each address type which is shown in main menue is 4th

octet

Scrolling in main menu with short-time keypress on set-key

Switch to next octet of the selected address type by short keypress on arrow-key 7.4. Octet scrolling

Octet scrolling is similar for all Address types.

actual state

change-over

S condition: short-time keypress on set key

S condition: long-time keypress on setkey (min. 3 seconds)

condition: short-time keypress on arrow key

B A L L U F F H W : 1 S W : 1 . 0

hard- and firmware-revision

B A L L U F F H W : 1 S W : 1 . 0

Address type: IP address

Hardware- and Firmware-revision

001

3rd octet

S

S

S

S

Address type: Subnet Mask

Address type: Gateway address

000

000

3rd octet

3rd octet

169

3rd octet 2nd octet 1st octet

001

254 001

4th octet

Page 19: BNI EIP-306-000-Z010 BNI EIP-306-100-Z010 - Balluffassets.balluff.com/WebBinary1/DOK_887581_01_000.pdf · BNI EIP-306-000-Z010 BNI EIP-306-100-Z010 ... BNI EIP-306 -100.. BNI EIP-306

Balluff Network Interface EtherNet/IP™

www.balluff.com 18

7 Display

7.5. IP Configuration

1. Long-time key press on set key starts editing mode. 2. Configuration of the selected value by short-time key press on arrow-key 3. After configuration store the new value by long-time keypress on set-key.

Note

To work with the new configuration, the module needs a power-down-reset.

Note

If a value has been changed, but the “old” address is still in use, the display shows an “unequal” symbol.

7.6. General

Information Differences between new configuration and the configuration the module is working

with are shown by a unequal-symbol.

In editing mode the screen flashes

If the module receives a single ping, the word “ping” is shown in the display screen for a few seconds. Afterwards the screen is reset to the screen which had been shown before. By short-time key press on set key the ping-mode can be left preterm.

The Led function at the display LEDs can be defined user specific by setting some bits in the process data inputs. (see “Process Data Outputs”)

The function plc-lock can also be used by setting a bit in the process data inputs. (See “Process Data Outputs”)

Note:

Editing Mode can not be chosen in display if the plc lock bit in process data inputs is set. (see “Process Data Outputs”)

001 005 S S

005 editing mode

Page 20: BNI EIP-306-000-Z010 BNI EIP-306-100-Z010 - Balluffassets.balluff.com/WebBinary1/DOK_887581_01_000.pdf · BNI EIP-306-000-Z010 BNI EIP-306-100-Z010 ... BNI EIP-306 -100.. BNI EIP-306

www.balluff.com 19

8 Webserver

8.1. General The BNI EIP-308 module includes an internal web server to get detailed information about the current state. Also you can use it to configurate the module and the connected IO Link devices. First make sure that a correct integration into your network has been done. To get a connection to the web server enter the IP address of the module to your browser address bar. A welcome page with a list of all Balluff Ethernet Network-interfaces is shown. Please use Internet Explorer 7 or higher.

8.2. Home

By click on “play”-button “Home” active.

You can get some information about the configuration and network-activity of the module. At the top of the window you can see the navigation bar which allows you to switch between the different web pages, just click on the corresponding text.

8.3. Diagnostic

Process On this page you can get some information about the module’s current process data by

having a look at the LEDs 8.4. Diagnostic Module On this page you can see the current module and network status like you can see it on the

module itself. 8.5. Configurations The configuration page allows you to configure the module. You can change network-

parameters and also assign own module information texts like a module description. This can only be used by entering a username and a password: Username: Balluff Password: BNIEIP

Page 21: BNI EIP-306-000-Z010 BNI EIP-306-100-Z010 - Balluffassets.balluff.com/WebBinary1/DOK_887581_01_000.pdf · BNI EIP-306-000-Z010 BNI EIP-306-100-Z010 ... BNI EIP-306 -100.. BNI EIP-306

Balluff Network Interface EtherNet/IP™

www.balluff.com 20

9 Appendix

9.1. Product Name

9.2. Order Code Product ordering code Order code

BNI EIP-306-000-Z010 BNI000L

BNI EIP-306-100-Z010 BNI0019

BNI EIP-308-100-Z010 BNI004Z

9.3. Included Material The BNI EIP consists of the following components:

I/O-block

4 blind plugs M12

Ground strap

Screw M4x6

20 labels

BNI EIP-308-100-Z010

Balluff Network Interface

Ethernet IP

Functions 306 = IP67 I/O-Module, 16 Inputs and 16 Outputs 308 = IP67 I/O-Module, 32 In- / Outputs

Variants 000 = without Display (Standard) 100 = Display version

Mechanical version Z010 = Material: Die-cast zinc housing Uplink: 1 x M12x1 internal thread Update: 1x M12x1 internal thread Power: 7/8” external thread I/O Ports: 16 x M12 x 1 internal thread

Page 22: BNI EIP-306-000-Z010 BNI EIP-306-100-Z010 - Balluffassets.balluff.com/WebBinary1/DOK_887581_01_000.pdf · BNI EIP-306-000-Z010 BNI EIP-306-100-Z010 ... BNI EIP-306 -100.. BNI EIP-306

www.balluff.com

www.balluff.com

Balluff GmbH Schurwaldstrasse 9 73765 Neuhausen a.d.F. Germany Tel. +49 7158 173-0 Fax +49 7158 5010 [email protected]

Nr.

88

758

1 E

E

ditio

n 1

20

3

Revis

ed

Editio

n 1

20

1

Sub

ject

to m

od

ific

ation