bhel haridwar

27
Industrial Training Project on Turbo Generators Presented By- 1

Upload: sandeep20022

Post on 17-Nov-2014

86 views

Category:

Documents


6 download

TRANSCRIPT

Page 1: bhel haridwar

Industrial Training Project

on Turbo Generators

Presented By-

1

Page 2: bhel haridwar

Overview of B.H.E.L.

Bharat Heavy Electricals Limited (B.H.E.L.) is the largest engineering and manufacturing enterprise in India.

BHEL caters to core sectors of the Indian Economy viz., Power Generation's & Transmission, Industry, Transportation, Telecommunication, Renewable Energy, Defense and many more.

2

BHEL has its setup spread all over India namely New Delhi,Gurgaon,Hardwar, Rudrapur, Jhansi, Bhopal, Hyderabad, Jagdishpur, Tiruchirapalli, Banglore and many more.

Page 3: bhel haridwar

B.H.E.L., Hardwar

Bharat Heavy Electricals Limited (B.H.E.L.), Hardwar has two manufacturing plants:-

Heavy Electrical Equipment Plant(HEEP) Central Foundry Forge Plant(CFFP)

3

Page 4: bhel haridwar

H.E.E.P.

Heavy Electrical Equipment Plant (HEEP) located in Hardwar is one of the major manufacturing plants of BHEL. The core business of HEEP includes design and manufacturing of large steam and gas turbines, turbo generators, hydro turbines and generators, large AC/DC motors and so on.

4

Page 5: bhel haridwar

The various blocks in HEEP are as follows:

Block-1: Turbo generator Shop Block-2: Fabrication Shop Block-3: Turbine Shop Block-4: Insulation Block Block-5: Forging Shop Block-6: Stamping Shop Block-7: Packing and Wood Working Shop Block-8: Condenser and Piping Shop New Blade Shop

5

Page 6: bhel haridwar

PROJECTTURBO GENERATORS

6

Page 7: bhel haridwar

BLOCK -1

Machine section Assembly section Hydro generator Stator winding

Machine section Iron assembly Heavy rotor assembly section Stator winding section Turbo generator Armature/Rotor section General assembly section Test stands

7

Page 8: bhel haridwar

8

STUDY OF TURBO GENERATOR

Page 9: bhel haridwar

TECHNICAL DATA

Rated data & output

Turbo generator

Main exciter Pilot exciter

Apparent power

588 MVA - 65kVA

Active power 500 MW 3780 KW -

Current 16.2 KA 5300 A 195 A

Voltage 21 KV 600 V 220 V

Frequency 50 Hz - 400 Hz

Power factor 0.85 - -

Hydrogen pressure

3.5 Bar - -

Rated field current

4040 A - -

Rated field voltage

340 V - -9

Page 10: bhel haridwar

RECTIFIER WHEEL

Number of fuses per rectifier wheel

30(800V ,800A)

Fuse resistance Approx 150 μ ohm

Number of diode per rectifier wheel

60

10

Page 11: bhel haridwar

The two pole uses hydrogen cooling for rotor

winding and direct water cooling stator winding.

Turbo generator consists of following parts:

o STATORo ROTORo BEARINGSo SHAFT BEARINGS

Other additional auxiliaries:o Excitation systemo Gas system

11

Constructional Features Of Turbo Generator

Page 12: bhel haridwar

STATOR

Stator consists of following parts:o Stator frameo Stator coreo Stator windingo Locating barso End shieldso Terminal bushingso Phase connectorso Hydrogen coolero End winding vibrationo Supervision of generator

12

Page 13: bhel haridwar

STATOR FRAME

13

Page 14: bhel haridwar

14

STATOR CORE

Page 15: bhel haridwar

ROTOR

Rotor consists of following parts:o Rotor shafto Rotor windingo Retaining ringo Field connectiono Fanso Rotor cooling system o Bearingso Shaft seals

15

Page 16: bhel haridwar

16

ROTOR SHAFT

Page 17: bhel haridwar

17

ROTOR WINDING

Page 18: bhel haridwar

RETAINING RING

18

Page 19: bhel haridwar

19

FAN

Page 20: bhel haridwar

AUXILLARY SYSTEMS

20

o GAS SYSTEM

o BRUSHLESS EXCITATION SYSTEM

oPERMANENT MAGNETIC PILOT EXCITER

oTHREE PHASE MAIN EXCITER

oAUTOMATIC VOLTAGE REGULATOR

oRECTIFIER WHEELS

oCOOLING SYSTEM

Page 21: bhel haridwar

21

RECTIFIER WHEEL

Page 22: bhel haridwar

22

The exciter is air cooled. The cooling air is

circulated in a closed circuit and recooled in two

cooling sections arranged along side the exciter.

The complete exciter is housed in an enclosure

draw the cool air in at both ends and expels the

warmed air to the compartment beneath the base

plate.The main exciter enclosure receives the cool

air from the fan after it passes over the pilot

exciter.

COOLING SYSTEM

Page 23: bhel haridwar

23

BRUSHLESS EXCITER

Page 24: bhel haridwar

24

PERMANENT MAGNET EXCITER

Page 25: bhel haridwar

25

Advantage Of Turbo Generator Over Hydro Generator

Page 26: bhel haridwar

26

CONCLUSION

o Turbo Generators are used where high frequency supply is required.

o As steam is used so no site problem.

Page 27: bhel haridwar

27

THANK YOU