betriebsanleitung dum modul atex, 3, en us · betriebsanleitung dum modul atex, 3, en_us subject:...

58
DUM Module ATEX Flow Monitor Operation instructions Flow monitor for use in explosion-hazard zones Series DUM Type DUM-4 thru DUM-250 Read this manual prior to performing any task!

Upload: others

Post on 29-May-2020

17 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Betriebsanleitung DUM Modul ATEX, 3, en US · Betriebsanleitung DUM Modul ATEX, 3, en_US Subject: DUM Module ATEX Flow Monitor Keywords: COSIMA go! stylesheet derivat version: 7.5.9

DUM Module ATEXFlow Monitor

Operation instructions

Flow monitor for usein explosion-hazard zones

Series DUMType DUM-4 thru DUM-250

Read this manual prior to performing any task!

Page 2: Betriebsanleitung DUM Modul ATEX, 3, en US · Betriebsanleitung DUM Modul ATEX, 3, en_US Subject: DUM Module ATEX Flow Monitor Keywords: COSIMA go! stylesheet derivat version: 7.5.9

DUM Modul ATEX, 3, en_US

© Meister Strömungstechnik GmbH 2019

Meister Strömungstechnik GmbH

Im Gewerbegebiet 2

63831 Wiesen

Germany

Telephone: +49 6096 9720 - 0

Fax: +49 6096 9720 - 30

E-mail: [email protected]

Internet: www.meister-flow.com

These instructions were compiled by:

Meister Strömungstechnik GmbH

Subject to change without notice

04.05.2020DUM Module ATEX Flow Monitor2

Page 3: Betriebsanleitung DUM Modul ATEX, 3, en US · Betriebsanleitung DUM Modul ATEX, 3, en_US Subject: DUM Module ATEX Flow Monitor Keywords: COSIMA go! stylesheet derivat version: 7.5.9

These instructions facilitate the safeand efficient handling of a flow monitor(referred to as "device" in the fol-lowing). The instructions are an inte-gral part of the device and must bekept within easy reach for the per-sonnel in the immediate vicinity of thedevice at all times. Personnel mustcarefully read and understand theseinstructions before commencing allwork. The basic requirement for safework is adherence to all safety andhandling instructions stipulated inthese instructions. The local accident-prevention regulations and generalsafety standards and regulations forthe field of application of the devicealso apply. Illustrations in theseinstructions are provided to aid generalunderstanding and might deviate fromthe actual model. No claims can bederived from any such differences.

Limitations of liability

All details and instructions in thismanual have been compiled underconsideration of the valid standardsand regulations, the current state-of-technology and our many years ofknowledge and experience. The manu-facturer does not accept any liabilityarising from:

n non-observance of any details inthese instructions

n improper use of the device, or usethat is not in accordance withthese instructions

n use of non-trained personnel

n unauthorized retrofitting or tech-nical changes that have not beenauthorized by the manufacturer

n use of non-approved replacementparts

The duties and obligations agreedupon in the delivery contract apply infull, as well as the general terms andconditions, the terms of delivery by themanufacturer and the valid legal regu-lations applicable at the conclusion ofthe contract.

Copyright

These operating instructions are pro-tected by copyright.

Except for internal purposes, transferof these instructions to third-parties,copying them in any way– even in part – as well as dissemina-tion and/or communication of their con-tent is forbidden without prior writtenauthorization from Meister Strömung-stechnik ("manufacturer"). Violationsare subject to claims for indemnifica-tion. The manufacturer reserves theright to assert additional claims.

Copyright is the property of the manu-facturer.

© Meister Strömungstechnik GmbH

Im Gewerbegebiet 2

63831 Wiesen

Germany

Supplemental directives

04.05.2020 DUM Module ATEX Flow Monitor 3

Page 4: Betriebsanleitung DUM Modul ATEX, 3, en US · Betriebsanleitung DUM Modul ATEX, 3, en_US Subject: DUM Module ATEX Flow Monitor Keywords: COSIMA go! stylesheet derivat version: 7.5.9

Table of contents1 Overview..................................................................................................... 6

1.1 Short description.................................................................................. 61.2 Warranty and guarantee provisions..................................................... 61.3 Customer service................................................................................. 6

2 Safety.......................................................................................................... 72.1 Explanation of symbols........................................................................ 72.2 Correct use in explosion-hazard zones .............................................. 82.3 Special precautions for use in explosion-hazard zones.................... 102.3.1 Precautions for use in explosion-hazard zones.............................. 112.4 Personnel requirements.................................................................... 122.5 Personal safety equipment................................................................ 132.6 Protective systems............................................................................ 13

3 Areas of employment............................................................................... 143.1 Mechanical component (flow meter without limit switch contacts

and electrical accessories)................................................................ 143.1.1 Exterior of the device...................................................................... 143.1.2 Interior of the device....................................................................... 143.1.3 General safety information for the mechanical component of the

device ............................................................................................ 153.1.4 Categorization of the mechanical component of the flow mon-

itor .................................................................................................. 163.1.5 List of media................................................................................... 193.1.6 Applicable documents.................................................................... 213.2 Electrical component of the device (limit switch contacts)................. 243.2.1 Categorization of the electrical component of the flow monitor

(limit switch contacts)..................................................................... 243.2.2 Applicable documents.................................................................... 24

4 Operating data.......................................................................................... 344.1 Operating data for the mechanical component of the device............ 344.2 Switch contact operating data........................................................... 34

5 Transport, packaging and storage......................................................... 36

Table of contents

04.05.2020DUM Module ATEX Flow Monitor4

Page 5: Betriebsanleitung DUM Modul ATEX, 3, en US · Betriebsanleitung DUM Modul ATEX, 3, en_US Subject: DUM Module ATEX Flow Monitor Keywords: COSIMA go! stylesheet derivat version: 7.5.9

6 Installation and initial startup................................................................. 376.1 Safety................................................................................................ 376.2 Tools.................................................................................................. 376.3 Protection of the flow monitor............................................................ 376.4 Electrical connection.......................................................................... 376.5 Grounding the device........................................................................ 376.6 Contact protection measures............................................................. 37

7 Operation.................................................................................................. 39

8 Troubleshooting....................................................................................... 40

9 Maintenance............................................................................................. 419.1 Return Materials................................................................................ 419.1.1 Return Materials Authorization....................................................... 41

10 Disassembly and disposal...................................................................... 42

11 Technical data.......................................................................................... 4311.1 Dimension sheet.............................................................................. 4311.2 General specifications...................................................................... 4611.3 Replacement parts........................................................................... 49

12 Annex........................................................................................................ 56

13 Index.......................................................................................................... 57

Table of contents

04.05.2020 DUM Module ATEX Flow Monitor 5

Page 6: Betriebsanleitung DUM Modul ATEX, 3, en US · Betriebsanleitung DUM Modul ATEX, 3, en_US Subject: DUM Module ATEX Flow Monitor Keywords: COSIMA go! stylesheet derivat version: 7.5.9

1 Overview1.1 Short description

Fig. 1: DUM flow monitor

1 Switch point adjustment scale2 Explosion-proof limit contact with

cast-on power cable

The flow monitor DUM monitors thecontinuous flow of liquids. It isdesigned for installation in pipe sys-tems.

A float inside the device is moved bythe medium flowing through it. Thedesired switch point can be set on theswitch point adjustment scale,whereby the arrow on the switch con-tact is aligned to the desired volumeflow value on the switch point adjust-ment scale.

Electrical monitoring is accomplishedby explosion-proof limit switches. Theelectrical connection is via the cast onpower cable.

1.2 Warranty and guar-antee provisions

Warranty and guarantee provisions arecontained in the general terms andconditions of the manufacturer.

1.3 Customer serviceFor technical information, please con-tact our customer service department(for contact details, see Page 2).

Furthermore, our staff is always inter-ested in receiving new information andexperiences gained from application ofthe device, which might be useful inimproving our products.

Overview

Customer service

04.05.2020DUM Module ATEX Flow Monitor6

Page 7: Betriebsanleitung DUM Modul ATEX, 3, en US · Betriebsanleitung DUM Modul ATEX, 3, en_US Subject: DUM Module ATEX Flow Monitor Keywords: COSIMA go! stylesheet derivat version: 7.5.9

2 SafetyThis Chapter provides an overview ofimportant safety aspects required foroptimum protection of personnel aswell as for safe installation and safeoperation of the device.

Non-observance of the handling andsafety instructions listed in this manualmay result in hazardous/dangerous sit-uations and in damage to property.

2.1 Explanation of sym-bols

Safety instructions

Safety instructions in this manual aremarked by symbols. The safetyinstructions are preceded by signalwords that indicate the level of danger/hazard.

To prevent accidents or injuries to per-sons as well as damage to property,always observe the safety instructionsand proceed carefully.

DANGER!

This combination of symbol andsignal word indicates an imme-diate, dangerous situation thatresults in death or serious injuryif it is not avoided.

WARNING!

This combination of symbol andsignal word indicates a possiblydangerous situation that mightresult in death or serious inju-ries if it is not avoided.

Safety

Explanation of symbols

04.05.2020 DUM Module ATEX Flow Monitor 7

Page 8: Betriebsanleitung DUM Modul ATEX, 3, en US · Betriebsanleitung DUM Modul ATEX, 3, en_US Subject: DUM Module ATEX Flow Monitor Keywords: COSIMA go! stylesheet derivat version: 7.5.9

CAUTION!

This combination of symbol andsignal word indicates a possiblydangerous situation that mightresult in minor or slight injuriesif it is not avoided.

NOTICE!

This combination of symbol andsignal word indicates a possiblydangerous situation that mightresult in damage to propertyand to the environment if it isnot avoided.

Tips and recommendations

This symbol emphasizes usefultips and recommendations aswell as information for efficientand failure-free operation.

Signs used in these instructions

The following symbols and highlightingare used in these instructions to iden-tify handling instructions, the descrip-tion of results, lists/enumerations, ref-erences and other elements:

Designates step-by-step han-dling instructions.

ð Designates a state or anautomatic sequence as aresult of a specific operatingstep.

n Designates randomly ordered enu-merations and list entries

Ä “Signs used in these instructions”on page 8, designates references tochapters in these instructions.

2.2 Correct use inexplosion-hazardzones

The device has been designed andconstructed exclusively for the correctuse in accordance with these instruc-tions

The flow monitor serves exclusively tomonitor the continuous flow of liquids.

The areas of application are specifiedin Chapter 3 of these instructions.

The admissible operating conditionsare specified in Chapter 4 of theseinstructions.

Safety

Correct use in explosion-hazard zones

04.05.2020DUM Module ATEX Flow Monitor8

Page 9: Betriebsanleitung DUM Modul ATEX, 3, en US · Betriebsanleitung DUM Modul ATEX, 3, en_US Subject: DUM Module ATEX Flow Monitor Keywords: COSIMA go! stylesheet derivat version: 7.5.9

Correct use of the device includes theobservance of all specifications inthese Operating Instructions, as wellas those for "DUM Module BASICS".

Any additional or different application,above and beyond the correct use inaccordance with these instructions isdeemed as incorrect use.

WARNING!

Danger due to incorrect use!– Use the flow monitor only

within the stipulated per-formance limits

– Do not subject the flowmonitor to severe tempera-ture fluctuations

– Do not use the flow monitorwith quick acting valves

– Do not use the flow monitorwith solenoid valves

– Do not subject the flowmonitor to vibrations

– Do not subject the flowmonitor to pressure surges

– Do not use the flow monitorwith media containingsolids or abrasives

– Only use the flow monitorwith media previouslyapproved by the manufac-turer

– Do not use the flow monitoras the sole monitoringdevice to prevent dan-gerous conditions

– Do not install the flow mon-itor as a load bearing partwithin a pipeline system

– The flow monitor must beinstalled so that it is pro-tected from damage bymechanical force. If neces-sary, install an appropriateimpact protection device.

Safety

Correct use in explosion-hazard zones

04.05.2020 DUM Module ATEX Flow Monitor 9

Page 10: Betriebsanleitung DUM Modul ATEX, 3, en US · Betriebsanleitung DUM Modul ATEX, 3, en_US Subject: DUM Module ATEX Flow Monitor Keywords: COSIMA go! stylesheet derivat version: 7.5.9

– The flow monitor may beinstalled in explosion-hazard zones only if:– the marking on the flow

monitor,– the marking on the

switch unit installed onthe flow monitor,

– and the informationcontained in theaccompanying docu-mentation (OperatingInstructions "DUMModule BASICS" and"DUM Module ATEX")authorize such installa-tion and operation

– Planning and design ofequipment, protective sys-tems and components isthe responsibility of thefacility operator.

– The potential impact, incase of an explosion, mustbe taken into account bythe facility operator.

– The facility operator isresponsible for the substi-tution, or the reduction ofthe quantity of substances,which may cause an explo-sive atmosphere.

All claims for damages due to incorrectuse are excluded.

Incorrect use of the flow monitor mayresult in dangerous situations.

2.3 Special precautionsfor use in explosion-hazard zones

The following chapter lists residualrisks that might arise from the device.

To reduce health risks and preventdangerous situations, observe thesafety instructions listed here, thesafety instructions listed in other chap-ters of these operating instructions, aswell as all safety instructions listed inthe Operating Instructions for "DUMModule BASICS".

These Operating Instructionscannot cover all conceivabledangers because many dan-gers arise, not from the deviceitself, but from the respectivemedia flowing through it.Always observe the appropriatesafety data sheets when usinghazardous media!

Safety

Special precautions for use in explosion-hazard zones

04.05.2020DUM Module ATEX Flow Monitor10

Page 11: Betriebsanleitung DUM Modul ATEX, 3, en US · Betriebsanleitung DUM Modul ATEX, 3, en_US Subject: DUM Module ATEX Flow Monitor Keywords: COSIMA go! stylesheet derivat version: 7.5.9

2.3.1 Precautions for usein explosion-hazardzones

DANGER!

Danger to life from explo-sions– Potentially explosive dust-

air mixtures and hybrid mix-tures are not allowed insidethe flow meter/flow monitorand must be excluded bythe operator!

– Dust accumulations are notallowed inside the flowmeter/flow monitor or onthe outside surface andmust be excluded by theoperator! When cleaning,do not use dry cloths!

– To avoid electrostaticcharges capable ofresulting in dangerous sit-uations, the followingrequirements must be met:– All conductive parts,

capable of electrostaticcharging, must be con-nected and grounded.

– Dangerous electro-static charging of non-conductive parts andmaterials, includingsolids, fluids and dust,must be avoided

– Ignitable dischargesmust be excluded.

– Chemical reactions, pyrol-ysis or biological processesinside the flow meter/flowmonitor are not allowedand must be excluded bythe operator.

– The entry of foreign mate-rials that may producesparks is not allowed andmust be excluded by theoperator.

– Friction, which may causelocal heat build-up andsparking, is not allowedand must be excluded bythe operator.

– Impact processes, involvingmaterials such as rust orlight alloys (e.g. aluminumor magnesium) are notallowed and must beexcluded by the operator.

– High voltage and currentsthat may cause sparkingare not allowed and mustbe excluded by the oper-ator.

– Electromagnetic waves in afrequency range between104 to 3×1012 Hz, as maybe found in the vicinity ofradio broadcasting stationsor high-frequency genera-tors, are not allowed andmust be excluded by theoperator.

Safety

Special precautions for use in explosion-hazard zones > Precautions for use in explosion-hazard zones

04.05.2020 DUM Module ATEX Flow Monitor 11

Page 12: Betriebsanleitung DUM Modul ATEX, 3, en US · Betriebsanleitung DUM Modul ATEX, 3, en_US Subject: DUM Module ATEX Flow Monitor Keywords: COSIMA go! stylesheet derivat version: 7.5.9

– Electromagnetic waves in afrequency range between3×1011 to 3×1015 Hz, whichcan occur as radiation fromprotective systems or com-ponents (e.g. lamps, arclamps, lasers), are notallowed and must beexcluded by the operator.

– Devices which can focusradiation, and which canprovide an ignition sourcefor particles and surfaces,are not allowed and mustbe excluded by the oper-ator.

– Ionizing radiation thatexceeds the minimum igni-tion temperature of the sur-rounding explosive atmos-phere, is not allowed andmust be excluded by theoperator.

– Ultrasound sources, whichcan ignite the sonicatedmaterial, are not allowedand must be excluded bythe operator.

– Adiabatic compression andshock waves are notallowed and must beexcluded by the operator.

– Exothermic reactions,including auto-ignition ofdust, is not allowed andmust be excluded by theoperator.

2.4 Personnel require-ments

WARNING!

Risk of injury due to use ofinsufficiently trained andqualified personnel!If unqualified personnel work onthe device or are located withinits hazard zone, dangers arisewhich may result in serious inju-ries and considerable damageto property.

– All work must be performedby qualified personnel only.

– Keep unqualified personnelaway from hazard zones

The personnel requirements, as formu-lated in the Operating Instructions for"DUM Module BASICS", Chapter 2.4,are valid. For employment withinexplosion-hazard zones, only trainedand qualified personnel may be used.Responsibility for the choice of per-sonnel and their qualification rests withthe facility operator. The requirementsfor standards DIN EN 60079-14 undDIN EN 60079-17 must be taken intoconsideration.

Refer also to the Operating Instruc-tions "DUM Module BASICS", Chapter2.9 "Responsibility of the owner"

Safety

Personnel requirements

04.05.2020DUM Module ATEX Flow Monitor12

Page 13: Betriebsanleitung DUM Modul ATEX, 3, en US · Betriebsanleitung DUM Modul ATEX, 3, en_US Subject: DUM Module ATEX Flow Monitor Keywords: COSIMA go! stylesheet derivat version: 7.5.9

Authorized personnel is to berestricted to those persons who can beexpected to carry out their work reli-ably. Persons whose ability to respondis influenced e.g. by drugs, alcohol ormedication, are not authorized.

Observe the age and occupational reg-ulations at the site when choosing per-sonnel.

2.5 Personal safetyequipment

Personal safety equipment is used toprotect personnel from hazards/dangers that might impair their safetyor health during work.

When performing the various tasks at,and with the device, personnel mustwear personal safety equipment. Spe-cial reference to this equipment ismade in the Operating Instructions for"DUM Module BASICS". The facilityoperator must ensure that the protec-tive clothing used in explosion hazardzones is suitable and approved.

2.6 Protective systemsThe design of the safety features isdescribed in the Operating Instructions"DUM Module BASICS". The operatormust ensure that all applicable regula-tions which apply to operations inexplosion-hazard zones are met.

Safety

Protective systems

04.05.2020 DUM Module ATEX Flow Monitor 13

Page 14: Betriebsanleitung DUM Modul ATEX, 3, en US · Betriebsanleitung DUM Modul ATEX, 3, en_US Subject: DUM Module ATEX Flow Monitor Keywords: COSIMA go! stylesheet derivat version: 7.5.9

3 Areas of employment3.1 Mechanical compo-

nent (flow meterwithout limit switchcontacts and elec-trical accessories)

3.1.1 Exterior of thedevice

n Device type DUM may beemployed in areas in which anexplosive atmosphere, composedof a gas/air- or dust/air- mixturemay occasionally occur. The exte-rior of the device may therefore besuitably located in explosionhazard zone 1. zone 2. zone 21 orzone 22.

n Dust accumulations are not per-mitted , neither internally, nor onthe outside surface of the flowmeter/flow monitor and must beexcluded by the operator.

3.1.2 Interior of the devicen Internal to the device, only those

flow media may be used, to whichthe following applies:

n the media is listed on the medialist (Chapter 3.1.5) and

n the media is not aggressive to thewetted parts of the device, and

n the device is approved by themanufacturer for use with theMedium.

n It is permissible to occasionallyhave an explosive gas/air mixtureinside the device (explosionhazard zone 1). At no time maygasses of explosion hazard groupIIC (e.g. hydrogen or acetylene)be present in the interior of thedevice.

n Explosive dust-air mixtures andhybrid mixtures are not permittedinside the flow meter/flow monitorand must be excluded by the oper-ator.

n Chemical reactions, pyrolysis orbiological processes inside theflow meter/flow monitor are notpermitted and must be excludedby the operator.

n The entry of foreign materials thatmay produce sparks is not per-mitted and must be excluded bythe operator.

Areas of employment

Mechanical component (flow meter without limit switch contacts and electrical accessories) > Interior of the device

04.05.2020DUM Module ATEX Flow Monitor14

Page 15: Betriebsanleitung DUM Modul ATEX, 3, en US · Betriebsanleitung DUM Modul ATEX, 3, en_US Subject: DUM Module ATEX Flow Monitor Keywords: COSIMA go! stylesheet derivat version: 7.5.9

3.1.3 General safety infor-mation for themechanical compo-nent of the device

n Dust accumulations are not per-mitted; neither internally, nor onthe outside surface of the flowmeter/flow monitor and must beexcluded by the operator. Whencleaning, do not use dry cloths!

n In case of hazard through staticelectricity, the following require-ments must be met:– All conductive parts capable

of charging themselves elec-trostatically must be con-nected and grounded.

– Dangerous electrostaticcharging of non-conductiveparts and materials, includingsolids, fluids and dust, mustbe avoided.

– Ignitable discharges must beexcluded.

n Friction, which may cause localheat build-up and sparking, is notpermitted and must be excludedby the operator.

n Impact processes involving mate-rials such as rust or light alloys(e.g. aluminum or magnesium) arenot permitted and must beexcluded by the operator.

n High voltage and currents thatmay cause sparking are not per-mitted and must be excluded bythe operator.

n Electromagnetic waves in a fre-quency range between 104 to3×1012 Hz, as may be found in thevicinity of radio broadcasting sta-tions, or high-frequency genera-tors, are not permitted and mustbe excluded by the operator.

n Electromagnetic waves in a fre-quency range between 3×1011 to3×1015 Hz, which can occur asradiation from protective systemsor components (e.g. lamps, arclamps, lasers) are not permittedand must be excluded by the oper-ator.

n Devices which can focus radiation,and which can provide an ignitionsource for particles and surfaces,are not permitted and must beexcluded by the operator.

n Ionizing radiation, which exceedsthe minimum ignition temperatureof the surrounding combustibleatmosphere, is not permitted andmust be excluded by the operator.

n Ultrasound sources, which canignite the sonicated material, arenot permitted and must beexcluded by the operator.

n Adiabatic compression and shockwaves are not permitted and mustbe excluded by the operator.

Areas of employment

Mechanical component (flow meter without limit switch contacts and electrical accessories) > General safety information for the mechanical compo-

nent of the device

04.05.2020 DUM Module ATEX Flow Monitor 15

Page 16: Betriebsanleitung DUM Modul ATEX, 3, en US · Betriebsanleitung DUM Modul ATEX, 3, en_US Subject: DUM Module ATEX Flow Monitor Keywords: COSIMA go! stylesheet derivat version: 7.5.9

n Exothermic reactions, includingauto-ignition of dust, are not per-mitted and must be excluded bythe operator.

n The device must be installed insuch a way as to precludedamage by outside force. It is theresponsibility of the operator toinstall appropriate protectivedevices.

3.1.4 Categorization ofthe mechanical com-ponent of the flowmonitor

n Equipment groupinternal: IIexternal: II

n Equipment categoryinternal: 2external: 2

n Atmosphereinternal: Gas (G)external: Gas (G), Dust (D)

n Type of protection: h (Construc-tional Safety "c")

n Gas groupinternal: IIBexternal: IIC, IIIC

n Temperature classificationinternal: T5, T6external: T5, T6external: T100 °C, T80 °COperating temperatures fordeviceswithout limit switch contactsThe maximum media tempera-ture for a device without limitswitch contacts must be lessthan:– the ignition temperature of the

medium and– the ignition temperature of the

atmosphere surrounding thedevice and

– less than or equal to 100 °C

Areas of employment

Mechanical component (flow meter without limit switch contacts and electrical accessories) > Categorization of the mechanical component of the

flow monitor

04.05.2020DUM Module ATEX Flow Monitor16

Page 17: Betriebsanleitung DUM Modul ATEX, 3, en US · Betriebsanleitung DUM Modul ATEX, 3, en_US Subject: DUM Module ATEX Flow Monitor Keywords: COSIMA go! stylesheet derivat version: 7.5.9

It is the responsibility of the oper-ator to ensure that these require-ments are met concurrently.The minimum media tempera-ture for a device without limitswitch contacts must be higheror equal to - 20 °C,whereby it must be ensured thatthe medium does not freeze.The maximum ambient tempera-ture for a device without limitswitch contacts must be lessthan:– the ignition temperature of the

medium and– the ignition temperature of the

atmosphere surrounding thedevice and

– less than or equal to 100 °C

It is the responsibility of the oper-ator to ensure that these require-ments are met concurrently.The minimum ambient tempera-ture for a device without limitswitch contacts must be higherthan or equal to - 20 °C.Operating temperatures for adevice with the following limitswitch contacts:Explosion proof switch contactswith design examination:PTB 03 ATEX 2154 X

II 2 G Ex mb IIC T6 GbII 2 D Ex tb IIIC T80 °C Db

The maximum media tempera-ture for a device with these limitswitch contacts must be lessthan:

– the ignition temperature of themedium and

– the ignition temperature of theatmosphere surrounding thedevice and

– less than or equal to 75 °C

It is the responsibility of the oper-ator to ensure that these require-ments are met concurrently.The minimum media tempera-ture for a device with these limitswitch contacts must be higherthan or equal to - 20 °C ,whereby it must be ensured thatthe medium does not freeze.The maximum ambient tempera-ture for a device with these limitswitch contacts must be lessthan:– the ignition temperature of the

medium and– the ignition temperature of the

atmosphere surrounding thedevice and

– less than or equal to 75 °C

It is the responsibility of the oper-ator to ensure that these require-ments are met concurrently.The minimum ambient tempera-ture for a device with these limitswitch contacts must be higherthan or equal to - 20 °C.Operating temperatures for adevice with the following limitswitch contacts:Explosion proof switch contactswith design examination:PTB 03 ATEX 2154 X

II 2 G Ex mb IIC T5 Gb

Areas of employment

Mechanical component (flow meter without limit switch contacts and electrical accessories) > Categorization of the mechanical component of the

flow monitor

04.05.2020 DUM Module ATEX Flow Monitor 17

Page 18: Betriebsanleitung DUM Modul ATEX, 3, en US · Betriebsanleitung DUM Modul ATEX, 3, en_US Subject: DUM Module ATEX Flow Monitor Keywords: COSIMA go! stylesheet derivat version: 7.5.9

II 2 D Ex tb IIIC T100 °C DbThe maximum media tempera-ture for a device with these limitswitch contacts must be lessthan:– the ignition temperature of the

medium and– the ignition temperature of the

atmosphere surrounding thedevice and

– less than or equal to 90 °C

It is the responsibility of the oper-ator to ensure that these require-ments are met concurrently.The minimum media tempera-ture for a device with these limitswitch contacts must be higherthan or equal to - 20 °C.It must be ensured that themedium does not freeze.The maximum ambient tempera-ture for a device with these limitswitch contacts must be lessthan:– the ignition temperature of the

medium and– the ignition temperature of the

atmosphere surrounding thedevice and

– less than or equal to90 °C

It is the responsibility of the oper-ator to ensure that these require-ments are met concurrently.The minimum ambient tempera-ture for a device with these limitswitch contacts must be higherthan or equal to - 20 °C.

n EPL (Equipment Protection Level):Gb (Gas), Db (Dust)

n Labeling of the mechanical com-ponent of the flow meter/flow mon-itor:internal: II 2G Ex h IIB T5, T6Gbexternal: II 2G Ex h IIC T5, T6Gbexternal: II 2D Ex h IIIC T100°C, T80 °C Db

Areas of employment

Mechanical component (flow meter without limit switch contacts and electrical accessories) > Categorization of the mechanical component of the

flow monitor

04.05.2020DUM Module ATEX Flow Monitor18

Page 19: Betriebsanleitung DUM Modul ATEX, 3, en US · Betriebsanleitung DUM Modul ATEX, 3, en_US Subject: DUM Module ATEX Flow Monitor Keywords: COSIMA go! stylesheet derivat version: 7.5.9

3.1.5 List of mediaMedia used Ignition temp. Explosion limit

[%]

Lower Upper

Argon Inert gas

Cargon gaseous mixtureArgon+CO2

CO2 Inert gas

CO2liquid

Diesel 255 (ASTME659-78) 0,6 6,5

Biodiesel SME Soya seed oilmethyl ester

285 (ASTME659-78)

Biodiesel RME Rape seed oilmethyl ester

283 (ASTME659-78)

EDC (1,2-Dichlorethane) 440 6,2 16

Natural gas 575 - 640 4 17

Ethanol 400 3,1

City gas 560

Gaseous mix-ture 90 %Argon + 10 %CO2

Gaseous mix-ture 96 %Argon + 4 %O2

Helium none none none

Air

Methane 595 4,4 16,5

Areas of employment

Mechanical component (flow meter without limit switch contacts and electrical accessories) > List of media

04.05.2020 DUM Module ATEX Flow Monitor 19

Page 20: Betriebsanleitung DUM Modul ATEX, 3, en US · Betriebsanleitung DUM Modul ATEX, 3, en_US Subject: DUM Module ATEX Flow Monitor Keywords: COSIMA go! stylesheet derivat version: 7.5.9

Media used Ignition temp. Explosion limit[%]

Lower Upper

Methanol 455 6,1 44

N2 none none none

N2O none none none

NaOH Natrium-hydroxide-NaOH ("causticsoda")

none none none

NaOH 50% none none none

Caustic sodaNaOH 25%

none none none

NH3 anhydrousammonia

630 15 28

n-Heptan(highly puri-fied)

215 1 6,7

O2 none none none

Oil

organic Saltsolution den-sity 1,35 kg/l20 °C

Peroxide none none none

RAF2 Raffinate 2 385 1,6 10

Spirits ofAmmonia(25%)

630 15 28

SO2 Sulphur dioxide none none none

Areas of employment

Mechanical component (flow meter without limit switch contacts and electrical accessories) > List of media

04.05.2020DUM Module ATEX Flow Monitor20

Page 21: Betriebsanleitung DUM Modul ATEX, 3, en US · Betriebsanleitung DUM Modul ATEX, 3, en_US Subject: DUM Module ATEX Flow Monitor Keywords: COSIMA go! stylesheet derivat version: 7.5.9

Media used Ignition temp. Explosion limit[%]

Lower Upper

Solvana 2000(Universalcleaningagent)

236 0,4 7

Petroleumether

>200 0,6 7

Water none none none

Water / Nitrite-solution

Hydrogenper-oxyde 50%(ultra pure)

none none none

Hydrogenper-oxyde 50weight.-%, dis-solved inWater

none none none

Propane 470 2,2 9,5

n-Butane 365 1,4 8,5

3.1.6 Applicable docu-ments

Areas of employment

Mechanical component (flow meter without limit switch contacts and electrical accessories) > Applicable documents

04.05.2020 DUM Module ATEX Flow Monitor 21

Page 22: Betriebsanleitung DUM Modul ATEX, 3, en US · Betriebsanleitung DUM Modul ATEX, 3, en_US Subject: DUM Module ATEX Flow Monitor Keywords: COSIMA go! stylesheet derivat version: 7.5.9

Areas of employment

Mechanical component (flow meter without limit switch contacts and electrical accessories) > Applicable documents

04.05.2020DUM Module ATEX Flow Monitor22

Page 23: Betriebsanleitung DUM Modul ATEX, 3, en US · Betriebsanleitung DUM Modul ATEX, 3, en_US Subject: DUM Module ATEX Flow Monitor Keywords: COSIMA go! stylesheet derivat version: 7.5.9

.

Areas of employment

Mechanical component (flow meter without limit switch contacts and electrical accessories) > Applicable documents

04.05.2020 DUM Module ATEX Flow Monitor 23

Page 24: Betriebsanleitung DUM Modul ATEX, 3, en US · Betriebsanleitung DUM Modul ATEX, 3, en_US Subject: DUM Module ATEX Flow Monitor Keywords: COSIMA go! stylesheet derivat version: 7.5.9

3.2 Electrical compo-nent of the device(limit switch con-tacts)

The electrical limit switch contactswere subjected to design examinationPTB 03 ATEX 2154 X

The limit switch contacts may only beemployed in combination with DUMtype devices in areas in which anexplosive atmosphere, composed of agas/air- or dust/air-mixture, may occa-sionally occur. The limit switch con-tacts of the device may therefore besuitably located in explosion hazardzone 1, zone 2, zone 21, or zone 22.Dust accumulations are not permittedon the limit switch contacts and mustbe excluded by the operator.

3.2.1 Categorization ofthe electrical com-ponent of the flowmonitor (limit switchcontacts)

n Device group: IIn Device category: 2n Atmosphere: Gas (G), Dust (D)n Gas group: IIC, Dust group: IIICn Ignition protection class (Gas): mb

(Encapsulation, application inzone 1 and 2)

n Ignition protection category (Dust):tb (protection by enclosure, appli-cation in zone 21 and 22)

n Temperature class (Gas): T5, T6

n Maximum permissible surfacetemperature (Dust): T 80 °C,T 100 °C

n EPL (Equipment Protection Level):Gb (Gas), Db (Dust)

3.2.2 Applicable docu-ments

The electrical limiting contacts weresubjected to a design examination

PTB 03 ATEX 2154 X

The following documents must beobserved:

Manufacturer's declaration for theemployment of explosion-proof switchunits within a safety concept

n Design examination certificate withattachments

n Conformity declaration (MeisterStrömungstechnik GmbH)

n Operating Instructions for theswitch units

Areas of employment

Electrical component of the device (limit switch contacts) > Applicable documents

04.05.2020DUM Module ATEX Flow Monitor24

Page 25: Betriebsanleitung DUM Modul ATEX, 3, en US · Betriebsanleitung DUM Modul ATEX, 3, en_US Subject: DUM Module ATEX Flow Monitor Keywords: COSIMA go! stylesheet derivat version: 7.5.9

Areas of employment

Electrical component of the device (limit switch contacts) > Applicable documents

04.05.2020 DUM Module ATEX Flow Monitor 25

Page 26: Betriebsanleitung DUM Modul ATEX, 3, en US · Betriebsanleitung DUM Modul ATEX, 3, en_US Subject: DUM Module ATEX Flow Monitor Keywords: COSIMA go! stylesheet derivat version: 7.5.9

Areas of employment

Electrical component of the device (limit switch contacts) > Applicable documents

04.05.2020DUM Module ATEX Flow Monitor26

Page 27: Betriebsanleitung DUM Modul ATEX, 3, en US · Betriebsanleitung DUM Modul ATEX, 3, en_US Subject: DUM Module ATEX Flow Monitor Keywords: COSIMA go! stylesheet derivat version: 7.5.9

Areas of employment

Electrical component of the device (limit switch contacts) > Applicable documents

04.05.2020 DUM Module ATEX Flow Monitor 27

Page 28: Betriebsanleitung DUM Modul ATEX, 3, en US · Betriebsanleitung DUM Modul ATEX, 3, en_US Subject: DUM Module ATEX Flow Monitor Keywords: COSIMA go! stylesheet derivat version: 7.5.9

Areas of employment

Electrical component of the device (limit switch contacts) > Applicable documents

04.05.2020DUM Module ATEX Flow Monitor28

Page 29: Betriebsanleitung DUM Modul ATEX, 3, en US · Betriebsanleitung DUM Modul ATEX, 3, en_US Subject: DUM Module ATEX Flow Monitor Keywords: COSIMA go! stylesheet derivat version: 7.5.9

Areas of employment

Electrical component of the device (limit switch contacts) > Applicable documents

04.05.2020 DUM Module ATEX Flow Monitor 29

Release: 03.09.2018 Page 1 of 4

OPERATING INSTRUCTIONS Explosion-proof contacts according to ATEX 2154 X

Technical Safety Data Model

SEM-A (SPDT/Change Over) + SEM-E (SPST/Normally Open)

Manufacturer: Meister Strömungstechnik GmbH / Im Gewerbegebiet 2 / D-63831 Wiesen

EN 60079-0: 2018 / EN 60079-18:2015 / EN 60079-18/A1:2018 / EN 60079-31:2014 T6 T5

Typ SEM – A… CE 0102 max. ambient temperature 75 °C Typ SEM – A… CE 0102 max. ambient temperature 90 °C

II 2G Ex mb IIC T6 Gb + II 2D Ex tb IIIC T80 Db II 2G Ex mb IIC T5 Gb + II 2D Ex tb IIIC T100 Db

Typ SEM – E… CE 0102 max. ambient temperature 75 °C Typ SEM – E… CE 0102 max. ambient temperature 90 °C

II 2G Ex mb IIC T6 Gb + II 2D Ex tb IIIC T80 Db II 2G Ex mb IIC T5 Gb + II 2D Ex tb IIIC T100 Db

Approval: EX-Type Examination Certificate PTB 03 ATEX 2154 X

Startup

The switch unit may only be connected to circuits with the following maximum ratings:

SEM-A: Umax: 250 V / Imax: 1 A / Pmax: 30 W

SEM-E: Umax: 250 V / Imax: 2 A / Pmax: 60 W

The circuit must not incorporate any effective inductivities or effective capacities. Above mentioned max. ratings must never be exceeded. For contact protection a fuse with the nominal value

of 1 A for SEM-A respectively 2 A for SEM-E

must be provided outside of the hazardous area for the circuit, unless the switch unit is connected to an intrinsically safe circuit. Application The switch unit may be used in potentially explosive atmospheres classified as Category 2.

Mounting The switch unit must be inserted between the mounting rails and then tightened with 2 screws.

Page 30: Betriebsanleitung DUM Modul ATEX, 3, en US · Betriebsanleitung DUM Modul ATEX, 3, en_US Subject: DUM Module ATEX Flow Monitor Keywords: COSIMA go! stylesheet derivat version: 7.5.9

Areas of employment

Electrical component of the device (limit switch contacts) > Applicable documents

04.05.2020DUM Module ATEX Flow Monitor30

Release: 03.09.2018 Page 2 of 4

Maintenance There is no maintenance required. Repairs are not permitted! Installation The electrical connections must be made in accordance to local safety regulations for electrical equipment and under observance of the regulations for the installation of electrical equipment in hazardous areas. The connection circuits must be designed with increased safety, if the device is not connected to intrinsically safe circuits. Adjustment Except for the switch point, no other adjustments have to be made. Relevant safety data The following limit must not, under any circumstances, be exceeded, even for a very short time. The following limit values must never be exceeded, even for short periods.

Type SEM-A (T5) SEM-E (T5) SEM-A (T6) SEM-E (T6) Operating voltage max. 250 V max. 250 V max. 250 V max. 250 V Switch current max. 1 A max. 2 A max. 1 A max. 2 A Contact Rating max. 30 W max. 60 W max. 30 W max. 60 W Max. ambient temperature

90 °C 90 °C 75 °C 75 °C

The unit must not be used in areas where electrostatic charging of the plastic housing might occur.

Page 31: Betriebsanleitung DUM Modul ATEX, 3, en US · Betriebsanleitung DUM Modul ATEX, 3, en_US Subject: DUM Module ATEX Flow Monitor Keywords: COSIMA go! stylesheet derivat version: 7.5.9

Areas of employment

Electrical component of the device (limit switch contacts) > Applicable documents

04.05.2020 DUM Module ATEX Flow Monitor 31

Release: 03.09.2018 Page 3 of 4

Warning Do not clean the switch unit with aggressive cleaning agents or solvents, nor store or install the unit in aggressive atmosphere to avoid damage to the employed plastics. Cleaning must not take place in potentially explosive areas. Ensure that the plastic housing is not electrostatically charged during cleaning. If this cannot be ensured, the housing must be discharged on all sides, outside the potentially explosive area, by means of a grounded metal plate before bringing the unit back into the potentially explosive area. In explosive areas, the plastic housing must under no circumstances be exposed to handling or processes which can lead to electrostatic charging of the housing. When removing the flowmeter and switch unit from the process line, ensure that no flow medium comes in contact with the switch housing and/or connecting cable. The sensor side of the switch unit (opposite the cable entry) is fragile due to its function and must be protected against mechanical damages when removed from the flow meter. The switch unit must be installed so that the connecting cable is not pinched, chafed or otherwise damaged and must not come in contact with parts which exceed temperatures of 75 °C (at T6) or 90 °C (at T5). The mounting of the switch unit onto flowmeters installed into a process line subjected to severe vibrations must be avoided, as this may cause malfunctions, such as loosening of the fixing screws, inexact measured values or cable failure. The switch unit must not be employed in machinery, plants or medical apparatus in which, should a malfunction arise, persons, animals or property could be injured or damaged.

Page 32: Betriebsanleitung DUM Modul ATEX, 3, en US · Betriebsanleitung DUM Modul ATEX, 3, en_US Subject: DUM Module ATEX Flow Monitor Keywords: COSIMA go! stylesheet derivat version: 7.5.9

Areas of employment

Electrical component of the device (limit switch contacts) > Applicable documents

04.05.2020DUM Module ATEX Flow Monitor32

Release: 03.09.2018 Page 4 of 4

Function test Warning The function test must be conducted outside the potentially explosive area. SEM-A: The function test is performed with a cable tester and a magnet. If measured between core 1 and 2 of the connecting cable, the cable tester must switch from “conductive” to “nonconductive” when the magnet is in approximation to the front side of the switch unit. If measured between core 1 and 3 of the connecting cable the action of the cable tester must be reversed. The dielectric resistance between the electrical connections and the housing must be > 10 MΩ.

Connection: Core No. 1 Common Core No. 2 Normally closed Core No. 3 Normally open

SEM-E: The function test is performed with a cable tester and a magnet. If the magnet is in approximation of the front side of the switch unit the cable tester must indicate “conductive” when the switch is triggered. The dielectric resistance between the electrical connections and the housing must be > 10 MΩ.

Connection: in any order

Safety recommendation The explosion proof safety can be increased when the switch unit is connected to an intrinsically safe circuit e. g. using a galvanic isolator with an intrinsically safe input circuit. The galvanic isolator must be mounted in the safe area. Wiesen, 3 September 2018

Page 33: Betriebsanleitung DUM Modul ATEX, 3, en US · Betriebsanleitung DUM Modul ATEX, 3, en_US Subject: DUM Module ATEX Flow Monitor Keywords: COSIMA go! stylesheet derivat version: 7.5.9

.

Areas of employment

Electrical component of the device (limit switch contacts) > Applicable documents

04.05.2020 DUM Module ATEX Flow Monitor 33

Page 34: Betriebsanleitung DUM Modul ATEX, 3, en US · Betriebsanleitung DUM Modul ATEX, 3, en_US Subject: DUM Module ATEX Flow Monitor Keywords: COSIMA go! stylesheet derivat version: 7.5.9

4 Operating dataOperating data for employment inexplosion-hazard zones.

4.1 Operating data forthe mechanicalcomponent of thedevice

The maximum operating pressure isspecified in Chapter 10.7 of the Oper-ating Instructions for "DUM ModuleBASICS".

The maximum media and ambienttemperatures for the mechanical com-ponent depend on various factors. It isthe responsibility of the operator tospecify the maximum temperatureswithin the framework set by the guide-lines in Ä Chapter 3.1.4 “Categoriza-tion of the mechanical component ofthe flow monitor ” on page 16 of theseOperating Instructions.

4.2 Switch contactoperating data

Operating data for the explosion-proofswitch unit with design examinationcertificate(PTB 03 ATEX 2154 X).

The following limit values must not beexceeded, not even for brief periods:

Table 1: Normally Open Contact(NOC), SEM-E (T6)

Max. operatingvoltage

250 V

Max. switch cur-rent

2 A

Max. switchingcapacity

60 VA

Max. ambienttemp for switchcontact

75 °C

Table 2: Normally Open Contact(NOC), SEM-E (T5)

Max. operatingvoltage

250 V

Max. switch cur-rent

2 A

Max. switchingcapacity

60 VA

Max. ambienttemp for switchcontact

90 °C

Operating data

Switch contact operating data

04.05.2020DUM Module ATEX Flow Monitor34

Page 35: Betriebsanleitung DUM Modul ATEX, 3, en US · Betriebsanleitung DUM Modul ATEX, 3, en_US Subject: DUM Module ATEX Flow Monitor Keywords: COSIMA go! stylesheet derivat version: 7.5.9

Table 3: Change-Over Contact, SEM-A(T6)

Max. operatingvoltage

250 V

Max. switch cur-rent

1 A

Max. switchingcapacity

30 VA

Minimum load 3 VA

Max. ambienttemp for switchcontact

75 °C

Table 4: Change-Over Contact, SEM-A(T5)

Max. operatingvoltage

250 V

Max. switchingcurrent

1 A

Max. switchcapacity

30 VA

Minimum load 3 VA

Max. ambienttemp for switchcontact

90 °C

Operating data

Switch contact operating data

04.05.2020 DUM Module ATEX Flow Monitor 35

Page 36: Betriebsanleitung DUM Modul ATEX, 3, en US · Betriebsanleitung DUM Modul ATEX, 3, en_US Subject: DUM Module ATEX Flow Monitor Keywords: COSIMA go! stylesheet derivat version: 7.5.9

5 Transport, packaging and storageTransport, packaging and storage innon-explosion-hazard zones aredescribed in Chapter 4, "DUM ModuleBASICS".

In explosion-hazard zones, in additionto the requirements described in theabove reference, all valid provisionsfor safety, accident prevention andenvironmental protection must be com-plied with.

Packaging procedures (wrapping/unwrapping) may only be conductedoutside the explosion-hazard zone.

DANGER!

Danger to life if packagingprocedures are conducted inexplosion-hazard zones.

n Packaging procedures may onlybe conducted outside the explo-sion-hazard zone.

Transport, packaging and storage

04.05.2020DUM Module ATEX Flow Monitor36

Page 37: Betriebsanleitung DUM Modul ATEX, 3, en US · Betriebsanleitung DUM Modul ATEX, 3, en_US Subject: DUM Module ATEX Flow Monitor Keywords: COSIMA go! stylesheet derivat version: 7.5.9

6 Installation and initial startupInstallation and initial startup in non-explosion-hazard zones are describedin Chapter 5, "DUM Module BASICS".In addition, for installation and initialstartup in explosion-hazard zones, thefollowing sections must be observed:

6.1 SafetyAll relevant safety-, accident preven-tion- and environmental protection reg-ulations must be followed for employ-ment in an explosion hazard zone.

6.2 ToolsTools, which may cause sparks, arenot to be employed. These tools mayonly be used when there is no poten-tially explosive atmosphere present.

The use of steel tools, of any kind, isprohibited in hazard zone 1, if there isrisk of explosion due to substances inexplosion hazard group IIC (in accord-ance with IEC/TR3 60079-20), (forexample, acetylene, hydrogen).

6.3 Protection of theflow monitor

The flow monitor must be installed insuch a way as to preclude damage byoutside force.

The facility operator is responsible forthe installation of an appropriateimpact protection shield.

6.4 Electrical connec-tion

Electrical connection is accomplishedthrough the cast on power cableleading from the switch housing. Allsafety advisories contained in theOperating Instructions for "DUMModule BASICS", Chapter 5, must beobserved. Additionally, for operation inexplosion-hazard zones, all valid provi-sions for safety, accident preventionand environmental protection must becomplied with.

6.5 Grounding thedevice

When installing the device in a pipesystem, ensure that the device isgrounded to the pipe system to avoid adangerous electrical potential differ-ence.

6.6 Contact protectionmeasures

Recommendations for contact protec-tion measures, when the device isemployed in a non-explosion-hazardzone, are described in chapter 5.9"Contact protection measures" of theOperating Instructions for "DUMModule BASICS". When the device isemployed in an explosion-hazardzone, only those contact protectionmeasures may be taken, which are

Installation and initial startup

Contact protection measures

04.05.2020 DUM Module ATEX Flow Monitor 37

Page 38: Betriebsanleitung DUM Modul ATEX, 3, en US · Betriebsanleitung DUM Modul ATEX, 3, en_US Subject: DUM Module ATEX Flow Monitor Keywords: COSIMA go! stylesheet derivat version: 7.5.9

consistent with all valid safety andaccident prevention measures forexplosion-hazard zones and the speci-fications contained in these OperatingInstructions.

Installation and initial startup

Contact protection measures

04.05.2020DUM Module ATEX Flow Monitor38

Page 39: Betriebsanleitung DUM Modul ATEX, 3, en US · Betriebsanleitung DUM Modul ATEX, 3, en_US Subject: DUM Module ATEX Flow Monitor Keywords: COSIMA go! stylesheet derivat version: 7.5.9

7 OperationOperation is described in Chapter 6,"DUM Module BASICS". All safety-and hazard warnings contained inChapter 6, "DUM Module BASICS",must be followed. For operation inexplosion-hazard zones, all valid provi-sions for safety, accident preventionand environmental protection must becomplied with.

Operation

04.05.2020 DUM Module ATEX Flow Monitor 39

Page 40: Betriebsanleitung DUM Modul ATEX, 3, en US · Betriebsanleitung DUM Modul ATEX, 3, en_US Subject: DUM Module ATEX Flow Monitor Keywords: COSIMA go! stylesheet derivat version: 7.5.9

8 TroubleshootingThe procedures in case of malfunctionare described in Chapter 7, "DUMModule BASICS". All safety- andhazard warnings, contained in Chapter7, "DUM Module BASICS", must befollowed. Additionally, for operation inexplosion-hazard zones, all valid provi-sions for safety, accident preventionand environmental protection must becomplied with.

Troubleshooting

04.05.2020DUM Module ATEX Flow Monitor40

Page 41: Betriebsanleitung DUM Modul ATEX, 3, en US · Betriebsanleitung DUM Modul ATEX, 3, en_US Subject: DUM Module ATEX Flow Monitor Keywords: COSIMA go! stylesheet derivat version: 7.5.9

9 MaintenanceMaintenance procedures aredescribed in Chapter 8, "DUM ModuleBASICS". All safety- and hazard warn-ings, contained in Chapter 8, "DUMModule BASICS", must be followed.For operation in explosion-hazardzones, all valid provisions for safety,accident prevention and environmentalprotection must be complied with.Maintenance procedures may only beperformed outside the explosion-hazard zone.

DANGER!

Danger to life if maintenanceprocedures are performed inthe explosion-hazard zone– Maintenance procedures

may only be performed out-side the explosion-hazardzone

9.1 Return Materials9.1.1 Return Materials

AuthorizationFor products being returned, regard-less of the reason, the currently validprovisions of the returns policy set byMEISTER will apply. Return shipmentswhich do not comply with the returnspolicy may be refused by MEISTER atthe expense of the consignor.

Maintenance

Return Materials > Return Materials Authorization

04.05.2020 DUM Module ATEX Flow Monitor 41

Page 42: Betriebsanleitung DUM Modul ATEX, 3, en US · Betriebsanleitung DUM Modul ATEX, 3, en_US Subject: DUM Module ATEX Flow Monitor Keywords: COSIMA go! stylesheet derivat version: 7.5.9

10 Disassembly and disposalDisassembly and disposal proceduresare described in Chapter 9, "DUMModule BASICS". All safety- andhazard warnings, contained in Chapter9, "DUM Module BASICS", must befollowed. For operation in explosion-hazard zones, all valid provisions forsafety, accident prevention and envi-ronmental protection must be compliedwith. Disassembly of the device mayonly be performed outside the explo-sion-hazard zone.

DANGER!

Danger to life if disassemblyprocedures are performed inthe explosion- hazard zone– Disassembly may only be

performed outside theexplosion hazard zone

– Disassembly in an explo-sion hazard zone may onlybe performed if there is norisk from an explosiveatmosphere

Disassembly and disposal

04.05.2020DUM Module ATEX Flow Monitor42

Page 43: Betriebsanleitung DUM Modul ATEX, 3, en US · Betriebsanleitung DUM Modul ATEX, 3, en_US Subject: DUM Module ATEX Flow Monitor Keywords: COSIMA go! stylesheet derivat version: 7.5.9

11 Technical data11.1 Dimension sheet

Fig. 2: Type DUM-55 ATEX

Technical data

Dimension sheet

04.05.2020 DUM Module ATEX Flow Monitor 43

Page 44: Betriebsanleitung DUM Modul ATEX, 3, en US · Betriebsanleitung DUM Modul ATEX, 3, en_US Subject: DUM Module ATEX Flow Monitor Keywords: COSIMA go! stylesheet derivat version: 7.5.9

Fig. 3: Type DUM-90 ATEX

Technical data

Dimension sheet

04.05.2020DUM Module ATEX Flow Monitor44

Page 45: Betriebsanleitung DUM Modul ATEX, 3, en US · Betriebsanleitung DUM Modul ATEX, 3, en_US Subject: DUM Module ATEX Flow Monitor Keywords: COSIMA go! stylesheet derivat version: 7.5.9

Fig. 4: Type DUM-220 ATEX and DUM-250 ATEX

Technical data

Dimension sheet

04.05.2020 DUM Module ATEX Flow Monitor 45

Page 46: Betriebsanleitung DUM Modul ATEX, 3, en US · Betriebsanleitung DUM Modul ATEX, 3, en_US Subject: DUM Module ATEX Flow Monitor Keywords: COSIMA go! stylesheet derivat version: 7.5.9

11.2 General specificationsType Overall dimensions (mm)

G DN SW L1 L2 T

DUM-4

1/4" 8 27 117 131 10

3/8" 10 27 117 131 15

1/2" 15 27 117 131 14

DUM-5

1/4" 8 27 117 131 10

3/8" 10 27 117 131 15

1/2" 15 27 117 131 14

DUM-8

1/4" 8 27 117 131 10

3/8" 10 27 117 131 15

1/2" 15 27 117 131 14

DUM-14

1/4" 8 27 117 131 10

3/8" 10 27 117 131 15

1/2" 15 27 117 131 14

DUM-28

1/4" 8 27 117 131 10

3/8" 10 27 117 131 15

1/2" 15 27 117 131 14

DUM-401/2" 15 27 132 146 14

3/4" 20 27 132 146 14

DUM-551/2" 15 32 132 174 15

3/4" 20 32 132 174 15

DUM-703/4" 20 40 130 152 15

1" 25 40 156 156 17

DUM-90 3/4" 20 40 130 152 15

Technical data

General specifications

04.05.2020DUM Module ATEX Flow Monitor46

Page 47: Betriebsanleitung DUM Modul ATEX, 3, en US · Betriebsanleitung DUM Modul ATEX, 3, en_US Subject: DUM Module ATEX Flow Monitor Keywords: COSIMA go! stylesheet derivat version: 7.5.9

Type Overall dimensions (mm)

G DN SW L1 L2 T

1" 25 40 156 156 17

DUM-1103/4" 20 40 130 152 15

1" 25 40 156 156 17

DUM-150 1 1/4" 32 50 200 200 20

DUM-2201 1/4" 32 50 200 200 20

1 1/2" 40 60 200 200 20

DUM-2501 1/4" 32 50 200 200 20

1 1/2" 40 60 200 200 20

Type Overall dimensions (mm)

G D1 D2 A1 A2 A3 A4 Weight(g)

DUM-4

1/4" 30 30 - - - 52

3/8" 30 30 - - - 52

1/2" 30 30 - - - 52

DUM-5

1/4" 30 30 - - - 52

3/8" 30 30 - - - 52

1/2" 30 30 - - - 52

DUM-8

1/4" 30 30 - - - 52

3/8" 30 30 - - - 52

1/2" 30 30 - - - 52

DUM-141/4" 30 30 - - - 52

3/8" 30 30 - - - 52

Technical data

General specifications

04.05.2020 DUM Module ATEX Flow Monitor 47

Page 48: Betriebsanleitung DUM Modul ATEX, 3, en US · Betriebsanleitung DUM Modul ATEX, 3, en_US Subject: DUM Module ATEX Flow Monitor Keywords: COSIMA go! stylesheet derivat version: 7.5.9

Type Overall dimensions (mm)

G D1 D2 A1 A2 A3 A4 Weight(g)

1/2" 30 30 - - - 52

DUM-28

1/4" 30 30 - - - 52

3/8" 30 30 - - - 52

1/2" 30 30 - - - 52

DUM-401/2" 30 30 - - - 52

3/4" 30 30 - - - 52

DUM-551/2" 35 30 - - - 52

3/4" 35 30 - - - 52

DUM-703/4" 40 40 - - - 62

1" 40 40 - - - 62

DUM-903/4" 40 40 - - - 62

1" 40 40 - - - 62

DUM-1103/4" 40 40 - - - 62

1" 40 40 - - - 62

DUM-150 11/4"

50 50 - - - 72

DUM-220

11/4"

50 50 - - - 72

11/2"

60 60 - - - 82

DUM-250

11/4"

50 50 - - - 72

11/2"

60 60 - - - 82

Technical data

General specifications

04.05.2020DUM Module ATEX Flow Monitor48

Page 49: Betriebsanleitung DUM Modul ATEX, 3, en US · Betriebsanleitung DUM Modul ATEX, 3, en_US Subject: DUM Module ATEX Flow Monitor Keywords: COSIMA go! stylesheet derivat version: 7.5.9

Type Overall dimensions (mm)

G D1 D2 A1 A2 A3 A4 Weight(g)

* NPT thread on request

** Sealed-in cable weight 2m ca. 80g

11.3 Replacement partsThe following replacement parts drawing provides an example of the configurationof a DUM ATEX flow monitor The actual configuration may vary depending on themodel.

Technical data

Replacement parts

04.05.2020 DUM Module ATEX Flow Monitor 49

Page 50: Betriebsanleitung DUM Modul ATEX, 3, en US · Betriebsanleitung DUM Modul ATEX, 3, en_US Subject: DUM Module ATEX Flow Monitor Keywords: COSIMA go! stylesheet derivat version: 7.5.9

Fig. 5: Type DUM-55 ATEX

Item Qty Designation

1 1 Process connection (inlet)

2 2 O-ring (seal)

3 1 Device housing

4 1 Pin (outlet) slot nozzle

Technical data

Replacement parts

04.05.2020DUM Module ATEX Flow Monitor50

Page 51: Betriebsanleitung DUM Modul ATEX, 3, en US · Betriebsanleitung DUM Modul ATEX, 3, en_US Subject: DUM Module ATEX Flow Monitor Keywords: COSIMA go! stylesheet derivat version: 7.5.9

Item Qty Designation

5 1 Slot nozzle

6 1 Spring

7 1 Float

8 1 Process connection (outlet)

9 2 Guide rail

10 4 Fixing screws (guide rail)

11 1 Switch contact with cable

12 2 Washer

13 2 Fixing screw (switch contact)

Technical data

Replacement parts

04.05.2020 DUM Module ATEX Flow Monitor 51

Page 52: Betriebsanleitung DUM Modul ATEX, 3, en US · Betriebsanleitung DUM Modul ATEX, 3, en_US Subject: DUM Module ATEX Flow Monitor Keywords: COSIMA go! stylesheet derivat version: 7.5.9

Fig. 6: Type DUM-90 ATEX

Item Qty Description

1 1 Process connection (inlet)

2 2 O-ring (seal)

3 2 Centering disc

4 1 Device body

5 1 Pin (outlet) slot nozzle

Technical data

Replacement parts

04.05.2020DUM Module ATEX Flow Monitor52

Page 53: Betriebsanleitung DUM Modul ATEX, 3, en US · Betriebsanleitung DUM Modul ATEX, 3, en_US Subject: DUM Module ATEX Flow Monitor Keywords: COSIMA go! stylesheet derivat version: 7.5.9

Item Qty Description

6 1 Slot nozzle

7 1 Spring

8 1 Float

9 1 Process connection (outlet)

10 2 Guide rail

11 4 Fixing screws (guide rail)

12 1 Switch contact with cable

13 2 Washer

14 2 Fixing screw (switch contact)

Technical data

Replacement parts

04.05.2020 DUM Module ATEX Flow Monitor 53

Page 54: Betriebsanleitung DUM Modul ATEX, 3, en US · Betriebsanleitung DUM Modul ATEX, 3, en_US Subject: DUM Module ATEX Flow Monitor Keywords: COSIMA go! stylesheet derivat version: 7.5.9

Fig. 7: Type DUM-220 ATEX and DUM-250 ATEX

Item No. ofpieces

Description

1 1 Threaded ring (inlet)

2 1 Device body

3 1 Pin (outlet) slot nozzle

Technical data

Replacement parts

04.05.2020DUM Module ATEX Flow Monitor54

Page 55: Betriebsanleitung DUM Modul ATEX, 3, en US · Betriebsanleitung DUM Modul ATEX, 3, en_US Subject: DUM Module ATEX Flow Monitor Keywords: COSIMA go! stylesheet derivat version: 7.5.9

Item No. ofpieces

Description

4 1 Slot nozzle

5 1 Spring

6 1 Float

7 1 Threaded ring (outlet)

8 2 Guide rail

9 4 Fixing screws, (guide rail)

10 1 Switch contact with cable

11 2 Washer

12 2 Fixing screw (switch contact)

Technical data

Replacement parts

04.05.2020 DUM Module ATEX Flow Monitor 55

Page 56: Betriebsanleitung DUM Modul ATEX, 3, en US · Betriebsanleitung DUM Modul ATEX, 3, en_US Subject: DUM Module ATEX Flow Monitor Keywords: COSIMA go! stylesheet derivat version: 7.5.9

12 AnnexThe required tools are specified inChapter 11.3 "Tools" of the OperatingInstructions for "DUM ModuleBASICS".

In explosion-hazard zones, tools whichmay cause sparks, are not to beemployed. These tools may only beemployed when there is no potentiallyexplosive atmosphere present.

The use of steel tools, of any kind, isprohibited in hazard zone 1, if there isa risk of explosion due to substancesin explosion hazard group IIC (inaccordance with IEC/TR3 60079-20),(for example, acetylene, hydrogen).

Annex

04.05.2020DUM Module ATEX Flow Monitor56

Page 57: Betriebsanleitung DUM Modul ATEX, 3, en US · Betriebsanleitung DUM Modul ATEX, 3, en_US Subject: DUM Module ATEX Flow Monitor Keywords: COSIMA go! stylesheet derivat version: 7.5.9

13 IndexAApplicable Documents . . . . . . . . . 24Atmosphere . . . . . . . . . . . . . . . . 24

CCategorization . . . . . . . . . . . . . . . 24

mechanical component . . . . . . 16

Contact . . . . . . . . . . . . . . . . . . . . 6Contact protection measures . . . . 37Copyright . . . . . . . . . . . . . . . . . . . 3Correct use . . . . . . . . . . . . . . . . . 8Customer service . . . . . . . . . . . . . 6

DDevice

electrical component . . . . . . . . 24

exterior . . . . . . . . . . . . . . . . . 14

interior . . . . . . . . . . . . . . . . . 14

Device category . . . . . . . . . . . . . 24Device group . . . . . . . . . . . . . . . 24Disassembly . . . . . . . . . . . . . . . . 42disposal . . . . . . . . . . . . . . . . . . . 42

EElectrical connection . . . . . . . . . . 37employment . . . . . . . . . . . . . . . . . 8Environmental protection regula-tions . . . . . . . . . . . . . . . . . . . . . 37

FFlow monitor

protection . . . . . . . . . . . . . . . 37

GGeneral

safety . . . . . . . . . . . . . . . . . . . 7

Grounding . . . . . . . . . . . . . . . . . 37

IIgnition protection category . . . . . . 24Initial start-up . . . . . . . . . . . . . . . 37Installation . . . . . . . . . . . . . . . . . 37

Llimit switch contacts . . . . . . . . . . . 24Limitation of liability . . . . . . . . . . . . 3List of media . . . . . . . . . . . . . . . . 19

MMaintenance . . . . . . . . . . . . . . . . 41

OOperating data

Mechanical component . . . . . . 34

switch contact . . . . . . . . . . . . 34

Operation . . . . . . . . . . . . . . . . . . 39

PPackaging . . . . . . . . . . . . . . . . . 36Personnel . . . . . . . . . . . . . . . . . . 12

Index

04.05.2020 DUM Module ATEX Flow Monitor 57

Page 58: Betriebsanleitung DUM Modul ATEX, 3, en US · Betriebsanleitung DUM Modul ATEX, 3, en_US Subject: DUM Module ATEX Flow Monitor Keywords: COSIMA go! stylesheet derivat version: 7.5.9

Precautionsexplosions . . . . . . . . . . . . . . . 11

general . . . . . . . . . . . . . . . . . 10

Protective systems . . . . . . . . . . . 13

RReplacement parts . . . . . . . . . . . 49Return Materials Authorization . . . 41

Ssafety equipment . . . . . . . . . . . . . 13Safety information

mechanical component . . . . . . 15

Safety regulations . . . . . . . . . . . . 37Service . . . . . . . . . . . . . . . . . . . . 6Storage . . . . . . . . . . . . . . . . . . . 36

Symbols usedin the instructions . . . . . . . . . . . 7

TTechnical data

Dimension sheet . . . . . . . . . . 43

General specifications . . . . . . . 46

Temperature class . . . . . . . . . . . . 24Temperature classification internal:T5, T6 external: T5, T6 . . . . . . . . . 18Tools . . . . . . . . . . . . . . . . . . 37, 56Transport . . . . . . . . . . . . . . . . . . 36Troubleshooting . . . . . . . . . . . . . 40

WWarranty and guarantee provisions 6

Index

04.05.2020DUM Module ATEX Flow Monitor58