  • PreliminaryThe information about the acA2000 and acA2040 camera models in this document is preliminary and all content is subject to change.

    Basler ace

    USERS MANUAL FOR GigE CAMERASDocument Number: AW000893Version: 14 Language: 000 (English)Release Date: 30 April 2012

  • For customers in the U.S.A.

    This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.

    You are cautioned that any changes or modifications not expressly approved in this manual could void your authority to operate this equipment.

    The shielded interface cable recommended in this manual must be used with this equipment in order to comply with the limits for a computing device pursuant to Subpart J of Part 15 of FCC Rules.

    For customers in Canada

    This apparatus complies with the Class A limits for radio noise emissions set out in Radio Interference Regulations.

    Pour utilisateurs au Canada

    Cet appareil est conforme aux normes Classe A pour bruits radiolectriques, spcifies dans le Rglement sur le brouillage radiolectrique.

    Life Support Applications

    These products are not designed for use in life support appliances, devices, or systems where malfunction of these products can reasonably be expected to result in personal injury. Basler customers using or selling these products for use in such applications do so at their own risk and agree to fully indemnify Basler for any damages resulting from such improper use or sale.

    Warranty Note

    Do not open the housing of the camera. The warranty becomes void, if the housing is opened.

    All material in this publication is subject to change without notice and is copyright Basler AG.

  • Contacting Basler Support Worldwide

    Europe:

    Basler AGAn der Strusbek 60 - 6222926 AhrensburgGermany

    Tel.: +49-4102-463-515Fax.: +49-4102-463-599

    bc.support.europe@baslerweb.com

    Americas:

    Basler, Inc.855 Springdale Drive, Suite 203Exton, PA 19341U.S.A.

    Tel.: +1-610-280-0171Fax.: +1-610-280-7608

    bc.support.usa@baslerweb.com

    Asia:

    Basler Asia Pte. Ltd8 Boon Lay Way# 03 - 03 Tradehub 21Singapore 609964

    Tel.: +65-6425-0472Fax.: +65-6425-0473

    bc.support.asia@baslerweb.com

    www.baslerweb.com

  • AW00089314000 Table of Contents

    Basler ace GigE i

    Table of Contents

    1 Specifications, Requirements, and Precautions . . . . . . . . . . . . . . . . . . . . . . . 11.1 Models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11.2 General Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21.3 Spectral Response . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14

    1.3.1 Mono Camera Spectral Response . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 141.3.2 Color Camera Spectral Response . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20

    1.4 Mechanical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 251.4.1 Camera Dimensions and Mounting Points. . . . . . . . . . . . . . . . . . . . . . . . . . . . 251.4.2 Maximum Allowed Lens Thread Length. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 271.4.3 Mechanical Stress Test Results. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29

    1.5 Software Licensing Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 301.6 Avoiding EMI and ESD Problems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 311.7 Environmental Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32

    1.7.1 Temperature and Humidity. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 321.7.2 Heat Dissipation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32

    1.8 Precautions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33

    2 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37

    3 Camera Drivers and Tools for Changing Camera Parameters . . . . . . . . . . . 393.1 The pylon Driver Package . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39

    3.1.1 The pylon Viewer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 403.1.2 The pylon IP Configuration Tool. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 403.1.3 The pylon API. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40

    4 Camera Functional Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 414.1 Overview (All Models Except acA2000-50, acA2040-25, acA2500-14) . . . . . . . . . . . . 414.2 Overview (acA2000-50, acA2040-25 Only) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 444.3 Overview (acA2500-14 Only) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46

    5 Physical Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 495.1 General Description of the Camera Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 495.2 Camera Connector Pin Assignments and Numbering . . . . . . . . . . . . . . . . . . . . . . . . . 50

    5.2.1 6-pin Connector Pin Assignments and Numbering . . . . . . . . . . . . . . . . . . . . . 505.2.2 8-pin RJ-45 Jack Pin Assignments and Numbering. . . . . . . . . . . . . . . . . . . . . 51

    5.3 Camera Connector Types. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 515.3.1 6-pin Connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 515.3.2 8-pin RJ-45 Jack . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51

    5.4 Camera Cabling Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 525.4.1 Ethernet Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 525.4.2 Standard Power and I/O Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 525.4.3 PLC Power and I/O Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54

    5.5 Camera Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55

  • Table of Contents AW00089314000

    ii Basler ace GigE

    5.6 Ethernet GigE Device Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 565.7 Input Line Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57

    5.7.1 Voltage Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 575.7.2 Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 585.7.3 Response Time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 595.7.4 Selecting the Input Line as the Source Signal for a Camera Function . . . . . . 60

    5.8 Output Line Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 615.8.1 Voltage Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 615.8.2 Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 615.8.3 Response Time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 645.8.4 Selecting a Source Signal for the Output Line . . . . . . . . . . . . . . . . . . . . . . . . . 64

    6 I/O Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 656.1 Configuring the Input Line . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65

    6.1.1 Selecting the Input Line as the Source Signal for a Camera Function . . . . . . 656.1.2 Input Line Debouncer. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 666.1.3 Setting the Input Line for Invert . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67

    6.2 Configuring the Output Line . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 686.2.1 Selecting a Source Signal for the Output Line . . . . . . . . . . . . . . . . . . . . . . . . . 686.2.2 Setting the State of a User Settable Output Line . . . . . . . . . . . . . . . . . . . . . . . 696.2.3 Setting the Output Line for Invert . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Recommended