BAL-40 WINDOWS & DOORS BUSHFIRE RATED SYSTEMS FOR BAL-40 ZONES In response to devastating bushfires, Australian Standard AS3959 has been updated and republished. AS3959:2009 is primarily concerned with improving the ability of buildings in designated bushfire prone areas to better withstand attack from bushfire thus giving a measure of protection to the building occupants (until the fire front passes) as well as to the building itself. AWS has developed and tested an extensive range of Vantage, Elevate™ and ThermalHEART™ Aluminium windows and doors to meet and exceed BCA requirements for compliance under Australian Standard AS3959-2009 for windows and doors in a BAL40 bushfire zone. These products are engineered, tested and certified to withstand the conditions likely to occur in a BAL40 zone and are designed to help you protect your home whilst still delivering unprecedented style, efficiency and functionality for your lifestyle. TESTED - CERTIFIED BAL40 BUSHFIRE ATTACK LEVELS (BALS) BAL – LOW Insufficient risk to warrant a construction response BAL – 12.5 Concern of ember attack BAL – 19 Increasing levels of ember attack and airborne burning debris. Increasing danger from radiant heat up to 19kwm² BAL – 29 Greater risk of damage from airborne burning debris Further risk from Radiant heat exposure up to 29kwm² BAL – 40 Burning debris ignited by windborne embers and radiant heat exposure up to 40kwm² Likelihood of direct flame contact BAL – FZ Direct flame contact from fire front & radiant heat exposure greater than 40kwm²

Upload: others

Post on 22-Jul-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: BAL-40 - Hanlon Windows Australia€¦ · and door systems which have been tested or certified for to comply with AS3959-2009 are identified with the BAL-40 logo illustrated below

BAL-40WINDOWS & DOORS BUSHFIRE RATED SYSTEMS FOR BAL-40 ZONES

In response to devastating bushfires, Australian

Standard AS3959 has been updated and

republished. AS3959:2009 is primarily concerned

with improving the ability of buildings in designated

bushfire prone areas to better withstand attack from

bushfire thus giving a measure of protection to the

building occupants (until the fire front passes) as well

as to the building itself.

AWS has developed and tested an extensive

range of Vantage, Elevate™ and ThermalHEART™

Aluminium windows and doors to meet and exceed

BCA requirements for compliance under Australian

Standard AS3959-2009 for windows and doors in a

BAL40 bushfire zone. These products are engineered,

tested and certified to withstand the conditions

likely to occur in a BAL40 zone and are designed

to help you protect your home whilst still delivering

unprecedented style, efficiency and functionality for

your lifestyle.

TESTED - CERTIFIEDBAL40

BUSHFIRE ATTACK LEVELS (BALS)

BAL – LOW Insufficient risk to warrant a construction response

BAL – 12.5 Concern of ember attack

BAL – 19 Increasing levels of ember attack and airborne burning debris. Increasing danger from radiant heat up to 19kwm²

BAL – 29 Greater risk of damage from airborne burning debris Further risk from Radiant heat exposure up to 29kwm²

BAL – 40 Burning debris ignited by windborne embers and radiant heat exposure up to 40kwm² Likelihood of direct flame contact

BAL – FZ Direct flame contact from fire front & radiant heat exposure greater than 40kwm²

Page 2: BAL-40 - Hanlon Windows Australia€¦ · and door systems which have been tested or certified for to comply with AS3959-2009 are identified with the BAL-40 logo illustrated below

BAL-40WINDOWS & DOORS BUSHFIRE RATED SYSTEMS FOR BAL-40 ZONES TESTED - CERTIFIED

BAL40

AWS COMPLIANT SYSTEMS

AWS has developed and tested an extensive range of Vantage, Elevate™ and ThermalHEART™ Aluminium windows and doors to meet and exceed BCA requirements for compliance under Australian Standard AS3959-2009 for windows and doors in a BAL-40 bush fire zone. The following AWS window systems will comply with these requirements.

PRODUCT LABELING

All AWS windows supplied as compliant for BAL-40 bushfire zones will be identified with the following adhesive label.

PRODUCT IDENTIFICATION

Throughout AWS brochures, websites and literature window and door systems which have been tested or certified for to comply with AS3959-2009 are identified with the BAL-40 logo illustrated below.

PRODUCT SPECIFICATION

When specifying AWS window and door systems for BAL-40 bushfire applications please make your fabricator aware of this requirement as specific glass, seals, hardware and components are required during manufacture to ensure compliance.

BAL-40TESTED-CERTIFIED

Series 502, 504, 506 Sliding Window ▲

Series 516 Awning Window ▲

Series 517 Awning Window ▲

Series 542 DStacker Sliding Door ▲

Series 549 Entry Door ▲

Series 548 French Doors ▲

Series 548 Bi-fold Doors ▲

Series 601, 602 Sliding Window ▲

Series 616 Awning Window ▲

Series 618 Sliding Door ▲

Series 726 Awning Window ▲

Series 729 Hinged Door ▲

Series 730 Bi-fold Door ▲

Series 731 Sliding Door ▲

Series 50 Commercial Door ▲

Series 52 Commercial Door ▲

Series 452 Commercial Sliding Window ▲

Series 456 Commercial Awning Window ▲

Series 461 Apartment Sliding Window ▲

Series 471 Apartment Sliding Door ▲

Series 410 FoldMASTER™ Bi-fold (Bottom rolling) ▲

Series 462 Architectural Sliding Window ▲

Series 466 Awning Window ▲

Series 650 Architectural Hinged Door ▲

Series 400 CentreGLAZE™ SG (102mm) ▲

Series 424 CentreGLAZE™ DG (102mm) ▲

Series 624 CentreGLAZE™ DG (150mm) ▲

Series 406 FrontGLAZE™ SG (102mm) ▲

Series 606 FrontGLAZE™ SG (150mm) ▲

Series 426 FrontGLAZE™ DG (102mm) ▲

Series 626 FrontGLAZE™ DG (150mm) ▲

Series 80 Narrow Offset (80mm) ▲

Series 600 Wide Offset (150mm) ▲

Series 804 Thermally Broken CentreGLAZE™ (100mm) ▲

Series 806 Thermally Broken CentreGLAZE™ (150mm) ▲

Series 824 Thermally Broken FrontGLAZE™ (100mm) ▲

Series 826 Thermally Broken FrontGLAZE™ (150mm) ▲

Series 852 Thermally Broken Commercial Door ▲

TESTED - CERTIFIEDBAL40

This product has been tested - certified to comply with BCA requirements for windows inBAL-40 Bush fire zones. Should this product or its components require repair or replacement

contact ARCHITECTURAL WINDOW SYSTEMS to maintain [email protected]

Page 3: BAL-40 - Hanlon Windows Australia€¦ · and door systems which have been tested or certified for to comply with AS3959-2009 are identified with the BAL-40 logo illustrated below

WINDOW AND DOOR REQUIREMENTS FOR BUSHFIRE PRONE AREAS

BAL-LOW

Standard window and door products may be used at this level. There are no special requirements

BAL- 12.5

WINDOWS

• Standardwindowsmustbecompletelyprotectedbyshutters complying with AS3959-2009 clause 5.5.1

or

• AtestedwindowsystemmustbeusedcompliantwithAS1530.8.1 2007, operable portion of the window must be screened internally or externally with metal screens with an aperture of 2mm made from corrosion resistant steel, bronze or aluminum

or

• Thefollowingdeemtosatisfyapproachcanbeused

• Allopeningsmustbescreenedinternallyorexternallywithmetalscreenswithanapertureof2mmmadefromcorrosionresistantsteel,bronzeoraluminium.

• Whereglazingislessthan400mmfromthegroundorotherstructures(decksetc)andlessthan18degreestothehorizontal,GradeAsafetyglassminimum4mmmustbeused.

• Ifwindowsincorporateglazingwithin400mmtotheground,theymustbemanufacturedfrom:a.Bushfireresistanttimber(AppendixF).b.Timberspecies(AppendixE)c.Metal/Aluminium.d.uPVCwithreinforcedcorrosionresistantsteel.

• Externallyfittedhardwarethatsupportsthesashinitsfunctionmustbemetal.

SIDE HUNG EXTERNAL DOORS & SLIDING DOORS

• Standarddoorsmustbecompletelyprotectedbyshutterscompliant to AS3959-2009 clause 5.5.1

or

• AtesteddoorsystemmustbeusedcompliantwithAS1530.8.1 2007, there is no requirement to screen the operable part of the door

or

• Thefollowingdeemtosatisfyapproachcanbeused

• WhereglazingisincorporatedglassshallbeGradeAsafetyinaccordancewithAS1288-2006.

• Side-hungdoorsrequiredraughtexcludersinstalledatthesill.Slidingdoorstohavetightfittingseals.

• Norequirementtoscreenoperableportionofaslidingdoor• Whereanypartofthedoorassemblyiswithin400mmtothegroundorotherstructures(decks),andlessthan18degreestothehorizontal,doorframesmustbemadefrom:

a.Bushfireresistanttimber(AppendixF). b.TimberspeciesaslistedinAppendixE. c.Metal/Aluminium. d.uPVCwithreinforcedcorrosionresistantsteel.

BAL-40WINDOWS & DOORS BUSHFIRE RATED SYSTEMS FOR BAL-40 ZONES TESTED - CERTIFIED

BAL40

WINDOW AND DOOR REQUIREMENTS FOR BUSHFIRE PRONE AREAS

When selecting windows or doors for bush fire prone areas it is necessary that systems comply with all relevant requirements, The details following illustrate AWS tested/certified systems v’s systems manufactured to comply based on a deem to satisfy approach. AWS recommends tested/certified systems are used at all Bush fire Attack Levels as this ensures the optimum appearance, functionality and integrity of the window or door system.

Grade A Glassmin 4mm

Grade A Glassmin 4mm

F

F

TESTED SYSTEM

DEEM-TO-SATISFY

F

Grade A Safey Glass

Grade A Safey Glass

TESTED SYSTEM

F

DEEM-TO-SATISFY

Allglazingwithin400mmofthegroundtobeGradeASafetymin4mm

Screentooperableareaonly

FocusisonEmberattack

GradeASafetyGlassasperAS1288-2006

Screensnotrequired

Doorsdeemedtobeclosedontheapproachofthefirefront

NorequirementtoscreenAWSBAL-40tested/certifiedsystems

Doorsdeemedtobeclosedontheapproachofthefirefront

RequirementtoscreentheoperableportionofAWSBAL-40tested/certifiedsystems

Assumedwindowsmaybeleftopenonapproachoffire

Page 4: BAL-40 - Hanlon Windows Australia€¦ · and door systems which have been tested or certified for to comply with AS3959-2009 are identified with the BAL-40 logo illustrated below

BAL- 19

WINDOWS

• Standardwindowsmustbecompletelyprotectedbyshutters complying with AS3959-2009 clause 6.5.1

or

• AtestedwindowsystemmustbeusedcompliantwithAS1530.8.1 2007, operable portion of the window must be screened internally or externally with metal screens with an aperture of 2mm made from corrosion resistant steel, bronze or aluminum

or

• The following deem to satisfy approach can be used

•Whereannealedglassisused,fixedandoperableportionsmustbescreened•Wheretoughenedglassisusedminimumis5mm&openingsmustbescreenedinternallyorexternallymadefromcorrosionresistantsteel,bronzeoraluminium.•Whereglazingislessthan400mmfromthegroundorotherstructures(decksetc)andlessthan18degreestothehorizontalandmorethan110mminwidth,5mmtoughenedmustbeused.•Externallyfittedhardwarethatsupportsthesashinitsfunctionmustbemetal.•Ifwindowassembliesarewithin400mmtotheground,theymustbemanufacturedfrom: a.Bushfireresistanttimber(AppendixF). b.TimberspeciesaslistedinAppendixE. c.Metal/Aluminium. d.uPVCwithreinforcedcorrosionresistantsteel.

SIDE-HUNG EXTERNAL DOORS & SLIDING DOORS

• Standarddoorsmustbecompletelyprotectedshutterscomplying with AS3959-2009 clause 3.7

or

• AtesteddoorsystemmustbeusedcompliantwithAS1530.8.1 2007, there is no requirement to screen the operable part of the door

or

• Thefollowingdeemtosatisfyapproachcanbeused

•Wheredoorsincorporateglazing,theglassmustbetoughened5mmminimum.•Whereanypartofthedoorassemblyiswithin400mmtothegroundorotherstructures(decks)andlessthan18degreestothehorizontal,doorframesmustbemanufacturedfrom:

a. Bushfireresistanttimber(AppendixF).b. TimberspeciesaslistedinAppendixE.c. Metal/Aluminium.d. uPVCwithreinforcedcorrosionresistantsteel.

•Side-hungdoorsrequiredraughtexcludersinstalledatthesill.Slidingdoorstohavetightfittingseals.•Norequirementtoscreenoperableportionofaslidingdoor

BAL-40WINDOWS & DOORS BUSHFIRE RATED SYSTEMS FOR BAL-40 ZONES TESTED - CERTIFIED

BAL40

F

Annealed Glass Annealed Glass

Annealed Glass Annealed Glass

F

TESTED SYSTEM

DEEM-TO-SATISFYwhereannealedglassisusedentirewindowmustbescreened

F

Toughened Glass Toughened Glass

Toughened Glass Toughened Glass

F

DEEM-TO-SATISFYwheretoughenedglassisusedoperableportionofthewindowmustbescreened

TESTED SYSTEM

DEEM-TO-SATISFY

F

Toughened GlassToughened Glass

ToughenedGlassonlymin5mm

Screensnotrequired

Slidingdoorsdeemedtobeclosedontheapproachofthefirefront

NorequirementtoscreenAWSBAL-40tested/certifiedsystems

Doorsdeemedtobeclosedontheapproachofthefirefront

RequirementtoscreentheoperableportionofAWSBAL-40tested/certifiedsystems

Assumedwindowsmaybeleftopenonapproachoffire

Page 5: BAL-40 - Hanlon Windows Australia€¦ · and door systems which have been tested or certified for to comply with AS3959-2009 are identified with the BAL-40 logo illustrated below

BAL- 29

WINDOWS

• Standardwindowsmustbecompletelyprotectedbyshutters complying with AS3959-2009 clause 7.5.1

or• Atestedwindowsystemmustbeusedcompliantwith

AS1530.8.1 2007, operable portion of the window must be screened internally or externally with metal screens with an aperture of 2mm made from corrosion resistant steel, bronze or aluminum

or• Thefollowingdeemtosatisfyapproachcanbeused

• Windowassembliesmustbemanufacturedfrom: a.Bushfireresistanttimber(AppendixF). b.Metal/Aluminium. c.uPVCwithreinforcedcorrosionresistantsteel

• Glazingmustbeaminimumof5mmtoughenedglass.•Whereglazingislessthan400mmfromthegroundorotherstructures(decksetc)andlessthan18degreestothehorizontalextendingmorethan110mminwidth,thatportionmustbescreened.

• Externallyfittedhardwarethatsupportsthesashinitsfunctionmustbemetal

• Theoperableportionandlowlightareamustbescreenedwithameshwithamaximumapertureof2mm,madefromacorrosionresistantsteel,bronzeoraluminium

SIDE-HUNG EXTERNAL DOORS

• Standarddoorsmustbecompletelyprotectedbyshutters complying with AS3959-2009 clause 7.5.1

or• Atesteddoorsystemmustbeusedcompliantwith

AS1530.8.1 2007, there is no requirement to screen the operable part of the door

or • Thefollowingdeemtosatisfyapproachcanbeused

•Wheredoorsincorporateglazing,theglassmustbetoughened6mmminimum.

• Externallyfittedhardwarethatsupportsthepanelinitsfunctionmustbemetal

•Whereanypartofthedoorassemblyiswithin400mmtothegroundorotherstructures(decks)andlessthan18degreestothehorizontalandextendingmorethan110mminwidth,thatareamustbescreenedorcoveredwithaperforatedsheet.

• Doorframesmustbemadefrom:a.Bushfireresistanttimber(AppendixF)b.Metal/Aluminium.c.uPVCwithreinforcedcorrosionresistantsteel.

• Side-hungdoorsrequiredraughtexcludersinstalledatsill.

SLIDING DOORS

• Standarddoorsmustbecompletelyprotectedbyshutters complying with AS3959-2009 clause 7.5.1 or completely screened with a mesh having an aperture of 2mm, made from corrosion resistant steel, bronze or aluminium.

or• Atesteddoorsystemmustbeusedcompliantwith

AS1530.8.1 2007, there is no requirement to screen the operable part of the door.

or • Thefollowingdeemtosatisfyapproachcanbeused

•Wheredoorsincorporateglazing,theglassmustbetoughened6mmminimum.

•With6mmToughenedglass,screeningisnotrequired.• Externallyfittedhardwarethatsupportsthepanelinitsfunctionmustbemetal

• Doorframesmustbemadefrom:• Bushfireresistanttimber(AppendixF)• Metal/Aluminium.• Slidingdoorsshallbetightfittinginframes

BAL-40WINDOWS & DOORS BUSHFIRE RATED SYSTEMS FOR BAL-40 ZONES TESTED - CERTIFIED

BAL40

F

Toughened Glass Toughened Glass

Toughened Glass

Toughened Glass Toughened Glass Toughened Glass Toughened Glass

Toughened Glass Toughened Glass Toughened Glass Toughened Glass

TESTED SYSTEM

DEEM-TO-SATISFY

TESTED SYSTEM

DEEM-TO-SATISFY

F

TESTED SYSTEM

DEEM-TO-SATISFY

F

F

Toughened GlassToughened Glass

400mm

5mmToughenedGlass

Screentooperableportion

400mmofglazedlowlightcoveredbyscreen(typicallynotpracticalsoentirelowlitewouldbescreened)

6mmToughenedglass

Thelower400mmofdoorglazingcoveredbyscreen

or

400mmhighdoorbottomrail

6mmToughenedGlass

Screensnotrequired

Slidingdoorsdeemedtobeclosedontheapproachofthefirefront

NorequirementtoscreenAWSBAL-40tested/certifiedsystems

Doorsdeemedtobeclosedontheapproachofthefirefront

NorequirementtoscreenAWSBAL-40tested/certifiedsystems

Doorsdeemedtobeclosedontheapproachofthefirefront

RequirementtoscreentheoperableportionofAWSBAL-40tested/certifiedsystems

Assumedwindowsmaybeleftopenonapproachoffire

Page 6: BAL-40 - Hanlon Windows Australia€¦ · and door systems which have been tested or certified for to comply with AS3959-2009 are identified with the BAL-40 logo illustrated below

BAL-40

WINDOWS

• Standardwindowsmustbecompletelyprotectedshutterscomplying with AS3959-2009 clause 8.5.1

or• Atestedwindowsystemmustbeusedcompliantwith

AS1530.8.1 2007, operable portion of the window must be screened internally or externally with metal screens with an aperture of 2mm made from corrosion resistant steel or bronze.

or• Thefollowingdeemtosatisfyapproachcanbeused

• Windowframesandhardwareshallbemetal(includesaluminium)

• Glazingmustbeaminimumof6mmtoughenedglass.• Boththeoperableandfixedportionsmustbescreenedwithameshwithamaximumapertureof2mm,madefromacorrosionresistantsteelorbronze.

• Sealstostiles,headandsillsshallbemanufacturedfrommaterialswithaflammabilityindexnogreaterthan5ormadefromsilicon

BAL-40 SIDE-HUNG EXTERNAL DOORS

• Standarddoorsmustbecompletelyprotectedbyshutterscomplying with AS3959-2009 clause 8.5.1

or • Atesteddoorsystemmustbeusedcompliantwith

AS1530.8.1 2007, there is no requirement to screen the operable part of the door

or • Thefollowingdeemtosatisfyapproachcanbeused

• Doorsshallbemadefromanon-combustible,timberdoorstobeaminimumthicknessof35mm

• Wheredoorsincorporateglazing,theglassmustbetoughened6mmminimum.

• Externallyfittedhardwarethatsupportsthepanelinitsfunctionmustbemetal

• Whereanypartofthedoorassemblyiswithin400mmtothegroundorotherstructures(decks)andlessthan18degreestothehorizontalandextendingmorethan110mminwidth,thatareamustbescreenedcoveredwithaperforatedsheet.

• Sealstostiles,headandsillsshallbemanufacturedfrommaterialswithaflammabilityindexnogreaterthan5ormadefromsilicon

• Side-hungdoorsrequiredraughtexcludersinstalledatsill.

BAL-40 Sliding doors

• Standarddoorsmustbecompletelyprotectedbyshutters complying with AS3959-2009 clause 8.5.1.

or • Atesteddoorsystemmustbeusedcompliantwith

AS1530.8.1 2007, there is no requirement to screen the operable part of the door

or • Thefollowingdeemtosatisfyapproachcanbeused

• Wheredoorsincorporateglazing,theglassmustbetoughened6mmminimum.

• With6mmToughenedglass,screeningisstillrequiredtobothoperableandfixedportions.

• Externallyfittedhardwarethatsupportsthepanelinitsfunctionmustbemetal

• Sealstostiles,headandsillsshallbemanufacturedfrommaterialswithaflammabilityindexnogreaterthan5ormadefromsilicon

• Slidingdoorsshallbetightfittinginframes

BAL-40WINDOWS & DOORS BUSHFIRE RATED SYSTEMS FOR BAL-40 ZONES TESTED - CERTIFIED

BAL40

TESTED SYSTEM

DEEM-TO-SATISFY

F

TESTED SYSTEM

DEEM-TO-SATISFY

Toughened Glass Toughened Glass Toughened Glass Toughened Glass

TESTED SYSTEM

DEEM-TO-SATISFY

F

6mmToughenedGlass

ScreenstoOperableandFixedareas

6mmToughenedglass

400mmofdoorglaz-ingcoveredbyscreen

or

400mmhighdoorbottomrail

SealswithaFlamma-bilityindexoflessthan5orsilicon

6mmToughenedGlass

Screenstofixed&operable

SealswithaFlammabilityindexoflessthan5orsilicon

NorequirementtoscreenAWSBAL-40tested/certifiedsystems

Doorsdeemedtobeclosedontheapproachofthefirefront

NorequirementtoscreenAWSBAL-40tested/certifiedsystems

Doorsdeemedtobeclosedontheapproachofthefirefront

RequirementtoscreentheoperableportionofAWSBAL-40tested/certifiedsystems

Assumedwindowsmaybeleftopenonapproachoffire

Page 7: BAL-40 - Hanlon Windows Australia€¦ · and door systems which have been tested or certified for to comply with AS3959-2009 are identified with the BAL-40 logo illustrated below

BAL-FZ (AS1530.8.2) Flame engulfment

• 9.5.1 – Where fitted, bushfire shutters shall comply with AS1530.8.2

• 9.5.2 – Windows shall be completely protected by bushfire shutters or have an FRL of -/30/- or comply with AS1530.8.2

• 9.5.3 – Side-hung doors shall be completely protected by bushfire shutters or have an FRL of -/30/- or comply with AS1530.8.2

• 9.5.4 – Sliding doors shall be completely protected by bushfire shutters or have an FRL of -/30/- or comply with AS1530.8.2

BAL-40WINDOWS & DOORS BUSHFIRE RATED SYSTEMS FOR BAL-40 ZONES TESTED - CERTIFIED

BAL40