b8018 tecnical

129
ZXG10 B8018 In-Door Base Transceiver Station Technical Manual Version 1.00 ZTE CORPORATION ZTE Plaza, Keji Road South, Hi-Tech Industrial Park, Nanshan District, Shenzhen, P. R. China 518057 Tel: (86) 755 26771900 800-9830-9830 Fax: (86) 755 26772236 URL: http://support.zte.com.cn E-mail: [email protected]

Upload: bikash-

Post on 16-Apr-2015

170 views

Category:

Documents


0 download

DESCRIPTION

V3 bts description

TRANSCRIPT

Page 1: B8018 tecnical

ZXG10 B8018In-Door Base Transceiver Station

Technical Manual

Version 1.00

ZTE CORPORATION ZTE Plaza, Keji Road South, Hi-Tech Industrial Park, Nanshan District, Shenzhen, P. R. China 518057 Tel: (86) 755 26771900 800-9830-9830 Fax: (86) 755 26772236 URL: http://support.zte.com.cn E-mail: [email protected]

Page 2: B8018 tecnical

LEGAL INFORMATION Copyright © 2006 ZTE CORPORATION. The contents of this document are protected by copyright laws and international treaties. Any reproduction or distribution of this document or any portion of this document, in any form by any means, without the prior written consent of ZTE CORPORATION is prohibited. Additionally, the contents of this document are protected by contractual confidentiality obligations. All company, brand and product names are trade or service marks, or registered trade or service marks, of ZTE CORPORATION or of their respective owners. This document is provided “as is”, and all express, implied, or statutory warranties, representations or conditions are disclaimed, including without limitation any implied warranty of merchantability, fitness for a particular purpose, title or non-infringement. ZTE CORPORATION and its licensors shall not be liable for damages resulting from the use of or reliance on the information contained herein. ZTE CORPORATION or its licensors may have current or pending intellectual property rights or applications covering the subject matter of this document. Except as expressly provided in any written license between ZTE CORPORATION and its licensee, the user of this document shall not acquire any license to the subject matter herein. The contents of this document and all policies of ZTE CORPORATION, including without limitation policies related to support or training are subject to change without notice.

Revision History

Date Revision No. Serial No. Reason for Revision

12/15/2006 R1.0 sjzl20061976 First edition

Page 3: B8018 tecnical

ZTE CORPORATION Values Your Comments & Suggestions! Your opinion is of great value and will help us improve the quality of our product documentation and offer better services to our customers.

Please fax to: (86) 755-26772236; or mail to Documentation R&D Department, ZTE CORPORATION, ZTE Plaza, A Wing, Keji Road South, Hi-Tech Industrial Park, Shenzhen, P. R. China 518057.

Thank you for your cooperation!

Document Name ZXG10 B8018 (V1.00) In-Door Base Transceiver Station Technical Manual

Product Version V1.00 Document Revision Number R1.0

Equipment Installation Date

Presentation: (Introductions, Procedures, Illustrations, Completeness, Level of Detail, Organization, Appearance)

Good Fair Average Poor Bad N/A

Accessibility: (Contents, Index, Headings, Numbering, Glossary)

Good Fair Average Poor Bad N/A

Your evaluation of this documentation

Intelligibility: (Language, Vocabulary, Readability & Clarity, Technical Accuracy, Content)

Good Fair Average Poor Bad N/A

Your suggestions for improvement of this documentation

Please check the suggestions which you feel can improve this documentation: Improve the overview/introduction Make it more concise/brief

Improve the Contents Add more step-by-step procedures/tutorials

Improve the organization Add more troubleshooting information

Include more figures Make it less technical

Add more examples Add more/better quick reference aids

Add more detail Improve the index

Other suggestions

__________________________________________________________________________

__________________________________________________________________________

__________________________________________________________________________

__________________________________________________________________________

__________________________________________________________________________

# Please feel free to write any comments on an attached sheet.

If you wish to be contacted regarding your comments, please complete the following:

Name Company

Postcode Address

Telephone E-mail

Page 4: B8018 tecnical

This page is intentionally blank.

Page 5: B8018 tecnical

Contents

About this Manual........................................................... ix

Purpose.............................................................................. ix Intended Audience ............................................................... ix Prerequisite Skill and Knowledge ............................................ ix What is in This Manual........................................................... x Related Documentation.......................................................... x Conventions........................................................................ xi How to Get in Touch............................................................ xii

Chapter 1..........................................................................1

System Description..........................................................1

System Background ..............................................................1 System Position and Role in Mobile Network .............................3 External Interfaces among System and Other NEs .....................4 System Structure..................................................................8

Chapter 2..........................................................................9

System Functions.............................................................9

System Functions .................................................................9

Chapter 3........................................................................15

Technical Indices ...........................................................15

Working Bands ................................................................... 15 RF Indices.......................................................................... 17 Physical Characteristics........................................................ 17 Voltage and Power Consumption ........................................... 17 Heat Dissipation ................................................................. 18 Environmental Characteristics............................................... 18 Capacity ............................................................................ 19 Clock ................................................................................ 19 Reliability .......................................................................... 19

Page 6: B8018 tecnical

Interface Specifications ........................................................19

Chapter 4........................................................................25

Structure and Principle..................................................25

Hardware..................................................................... 25 Cabinet..............................................................................25 Clock Distribution ................................................................27 Time Slot Switching .............................................................28 Overall Hardware Structure ..................................................29

Software...................................................................... 31 Software Structure ..............................................................31

System Working Principle ............................................... 36

Chapter 5........................................................................39

Hardware Components Introduction ............................39

Cabinet Composition............................................................39

Cabinet Top ................................................................. 40 Cabinet Top Structure ..........................................................40 Cabinet Top Interfaces .........................................................41

Subracks ..................................................................... 50

Top-Layer Subrack ..............................................................50 Carrier Subrack...................................................................51 Fan Subrack .......................................................................51 Air Filter Subrack ................................................................52 Backplane ..........................................................................53

Boards, Modules and Switches ........................................ 55

Controller & Maintenance Board (CMB) ...................................55 E1/T1 Interface Board (EIB)..................................................61 Power Distribution Module (PDM)...........................................63 Transceiver Module for EDGE (DTRU) .....................................64 AEM (Antenna Equipment Module) .........................................67

Chapter 6........................................................................87

Networking Modes and Configuration...........................87

Networking Modes ...............................................................87

Configuration ............................................................... 89 Configuration Principles........................................................89 Configuration Examples of Various Site Types..........................90

Page 7: B8018 tecnical

Appendix A...................................................................105

Abbreviation.................................................................105

Appendix B...................................................................109

Figures..........................................................................109

Tables...........................................................................113

Index............................................................................115

Page 8: B8018 tecnical

This page is intentionally blank.

Page 9: B8018 tecnical

Confidential and Proprietary Information of ZTE CORPORATION ix

About this Manual

Purpose

This manual provides principles, specifications, functions and technical features of ZXG10 B8018 (V1.00). It describes architecture, technical indices, interfaces and communications, networking, and system configuration of overall BTS.

Intended Audience

This document is intended for engineers and technicians who perform operation activities on the ZXG10 B8018 (V1.00).

Prerequisite Skill and Knowledge

To use this document effectively, users should have a general understanding of mobile communications technology. Familiarity with the following is helpful:

ZXG10 BSS and its various components

GSM Technology and equipment

ZXG10-BTS (V2) series, and its technical and hardware details

Page 10: B8018 tecnical

ZXG10 B8018 (V1.00) In-Door Base Transceiver Station Technical Manual

x Confidential and Proprietary Information of ZTE CORPORATION

What is in This Manual

This Manual contains the following chapters:

T AB L E 1 - C H AP T E R S U M M AR Y

Chapter Summary

Chapter 1, System Description

Gives the system background, position and role in mobile network, external interfaces among system and other NEs and system structure of ZXG10 B8018 (V1.00).

Chapter 2, System Functions

Describes the system Functions of ZXG10 B8018 (V1.00).

Chapter 3, Technical Indices

Describes the technical specifications of ZXG10 B8018 (V1.00).

Chapter 4, Structure and Principle

Describes the hardware and software structure and system working principle of ZXG10 B8018 (V1.00).

Chapter 5, Hardware Components Introduction

Describes different hardware boards and units of ZXG10 B8018 (V1.00).

Chapter 6, Networking Modes and Configuration

Explains various networking modes, configuration principles, connections, and configurations of ZXG10 B8018 (V1.00).

Appendix A, Abbreviations

Lists all the abbreviations used in the manual.

Appendix B, Tables & Figures

Lists all the tables and figures appeared in the manual.

Index Lists the important words appeared in the table.

Related Documentation

The following documentation is related to this manual:

ZXG10 B8018 (V1.00) In-Door Base Transceiver Station Documentation Guide

ZXG10 B8018 (V1.00) In-Door Base Transceiver Station Installation Manual

ZXG10 B8018 (V1.00) In-Door Base Transceiver Station Maintenance Manual(Routine Maintenance)

ZXG10 B8018 (V1.00) In-Door Base Transceiver Station Maintenance Manual(Troubleshooting)

Page 11: B8018 tecnical

About this Manual

Confidential and Proprietary Information of ZTE CORPORATION xi

Conventions

ZTE documents employ the following typographical conventions.

T AB L E 2 - TY P O G R AP H I C AL C O N V E N T I O N S

Typeface Meaning

Italics References to other Manuals and documents.

“Quotes” Links on screens.

Bold Menus, menu options, function names, input fields, radio button names, check boxes, drop-down lists, dialog box names, window names.

CAPS Keys on the keyboard and buttons on screens and company name.

Constant width Text that you type, program code, files and directory names, and function names.

[ ] Optional parameters.

Mandatory parameters.

| Select one of the parameters that are delimited by it.

Note: Provides additional information about a certain topic.

Checkpoint: Indicates that a particular step needs to be checked before proceeding further.

Tip: Indicates a suggestion or hint to make things easier or more productive for the reader.

T AB L E 3 - M O U S E OP E R AT I O N C O N V E N T I O N S

Typeface Meaning

Click Refers to clicking the primary mouse button (usually the left mouse button) once.

Double-click Refers to quickly clicking the primary mouse button (usually the left mouse button) twice.

Right-click Refers to clicking the secondary mouse button (usually the right mouse button) once.

Drag Refers to pressing and holding a mouse button and moving the mouse.

Typographical Conventions

Mouse Operation

Conventions

Page 12: B8018 tecnical

ZXG10 B8018 (V1.00) In-Door Base Transceiver Station Technical Manual

xii Confidential and Proprietary Information of ZTE CORPORATION

How to Get in Touch

The following sections provide information on how to obtain support for the documentation and the software.

If you have problems, questions, comments, or suggestions regarding your product, contact us by e-mail at [email protected]. You can also call our customer support center at (86) 755 26771900 and (86) 800-9830-9830.

ZTE welcomes your comments and suggestions on the quality and usefulness of this document. For further questions, comments, or suggestions on the documentation, you can contact us by e-mail at [email protected]; or you can fax your comments and suggestions to (86) 755 26772236. You can also browse our website at http://support.zte.com.cn, which contains various interesting subjects like documentation, knowledge base, forum and service request.

Customer Support

Documentation Support

Page 13: B8018 tecnical

Confidential and Proprietary Information of ZTE CORPORATION 1

C h a p t e r 1

System Description

This chapter gives the system background, position and role in mobile network, external interfaces among system and other NEs, and system structure of ZXG10 B8018 (V1.00).

System Background

GSM digital mobile communication system consists of MSS, BSS and MS. BSS consists of BSC, which is the control center, and BTS, which is the radio transceiver.

BTS is controlled by BSC, which serves one or more cells. BSC implements radio transmission and relevant control of the air interface between BSS and MS, and implement radio resource management with BS.

ZXG10 B8018 (V1.00) is one of the ZXG10-BTS series of base transceiver stations, and is an indoor macro cell BTS of third-generation for GSM. It employs many new technologies based on ZXG10-BTS (V2) and achieves improvement in software, hardware, and system reliability.

Page 14: B8018 tecnical

ZXG10 B8018 (V1.00) In-Door Base Transceiver Station Technical Manual

2 Confidential and Proprietary Information of ZTE CORPORATION

Figure 1 shows the GSM network.

F I G U R E 1 – GSM N E T W O R K

ZXG10 B8018 (V1.00) applies to heavy traffic zones, and can be used for rural areas and expressways.

Page 15: B8018 tecnical

Chapter 1 – System Description

Confidential and Proprietary Information of ZTE CORPORATION 3

System Position and Role in Mobile Network

Figure 2 shows the ZXG10 B8018 (V1.00) in a GSM/GPRS network.

F I G U R E 2 – ZXG10 B8018 (V1 .00 ) I N A GSM/GPRS NE T W O R K

In a GSM/GPRS network, ZXG10 B8018 (V1.00) is the radio transceiver for GSM BSS. BSC controls BTS, and one BTS serves a certain cell or several cells.

Abis interface connects BTS to BSC. It helps BSC to manage radio resources, and achieve radio transmission with MS and relevant control functions through Um interface. It implements layer-1 and layer-2 protocols on the radio link and related control functions.

System Position in

Mobile Network

Relationship between

System and Other NEs and

Realized Functions

Page 16: B8018 tecnical

ZXG10 B8018 (V1.00) In-Door Base Transceiver Station Technical Manual

4 Confidential and Proprietary Information of ZTE CORPORATION

External Interfaces among System and Other NEs

In PLMN, MS connects fixed parts of the network through a radio channel to enable subscribers to access communication services. A set of standards is set up along with a series of conditions provided to interconnect MS with BTS for signal transmission over the radio channel. This set of specifications about signal transmission over radio channel is the Um interface.

Um interface hierarchical model constitutes both circuit service protocol as well as packet service protocol and both are shown in Figure 3 and Figure 4, respectively. The packet service protocol is used at BSC side and here only physical layer is discussed.

F I G U R E 3 - C I R C U I T S E R V I C E P R O T O C O L H I E R AR C H Y O F UM I N T E R F AC E

C M

M M

R R

L A P D m

S i g . L 1 S i g . L 1

L A P D m

R R

M SB T S

U m I n t e r f a c e

F I G U R E 4 - P AC K E T S E R V I C E P R O T O C O L ST AC K S T R U C T U R E O F UM I N T E R F AC E

M S

U m G b

B S S S G S N

B S S G P

L L C

S N D C P

N e t w o r kS e r v ic e

L 1 b is

r e la y

B S S G P

L 1 b is

R L C

M A C

G S M R F

r e la y

R L C

M A C

G S M R F

S N D C P

I P / X . 2 5

a p p l ic a t io n

L L C

N e t w o r kS e r v ic e

Um Interface

Page 17: B8018 tecnical

Chapter 1 – System Description

Confidential and Proprietary Information of ZTE CORPORATION 5

On the Um interface, the circuit service protocol falls into three layers as follows:

Layer-1 (bottom) is the physical layer, consists of various channels and provides the basic wireless channels for upper level message transmission.

Layer-2 (middle) is the data link layer with the LAPDm used which controls and transmits the data between MS and BTS.

Layer-3 (top) is the highest layer, which comprises of various messages and programs and provides service control. Layer 3 consists of three sub-layers:

Radio Resource Management (RR)

Mobility Management (MM)

Connection Management (CM)

Relevant protocols of Um interface are as follows:

GSM 04.03 describes the channel structure and access capability.

GSM 04.04 specifies the physical layer structure.

GSM 04.05 specifies the data link layer protocols.

GSM 04.08 specifies the layer 3 protocols.

Abis interface sends signal from BSC to BTS through standard E1 cable of PCM. The unbalanced input mode of 75 Ω or the balanced input mode of 120 Ω coaxial cable is used to access through transmission equipment such as digital microwave, fiber transmission (SDH and PDH), and the satellite link. Physically, an E1 interface is used as Abis interface and it is connected with the thin coaxial cable and D-socket.

Abis interface hierarchical model constitutes circuit service protocol as shown in Figure 5. The Abis interface does not process the packet service protocol and it is transparent for packet signaling.

Abis Interface

Page 18: B8018 tecnical

ZXG10 B8018 (V1.00) In-Door Base Transceiver Station Technical Manual

6 Confidential and Proprietary Information of ZTE CORPORATION

F I G U R E 5 - C I R C U I T S E R V I C E S T R U C T U R E O F AB I S I N T E R F AC E

A b i s I n t e r f a c e

B T S

B T S M

L A P D

S i g . L 1

B S C

S i g . L 2

L A P D

B T S M

R R

On the Abis interface, the circuit service protocol falls into three layers as follows:

Layer-1 (bottom) is the physical layer and it is the PCM digital link at the rate of 2 Mbps.

Layer-2 (middle) is the data link layer and it is based on LAPD.

Layer-3 (top) transparently transmits the layer-3 messages on Abis interface and manages radio resources.

Relevant protocols of Abis interface are as follows:

GSM 08.52 presents basic principles and rules of other specifications for Abis interface and how the service functions are divided between BSC and BTS.

GSM 08.54 specifies physical structure of Abis interface.

GSM 08.56 specifies data link layer protocols of Abis interface.

GSM 08.58 stipulates layer-3 protocols of Abis interface.

GSM 12.21 specifies O&M message transmission mechanism on the Abis interface.

Figure 6 shows the flexible example of the Abis interface timeslot configuration.

Page 19: B8018 tecnical

Chapter 1 – System Description

Confidential and Proprietary Information of ZTE CORPORATION 7

F I G U R E 6 - E X AM P L E O F AB I S I N T E R F AC E T I M E S L O T C O N F I G U R AT I O N

O&M TSs on the Abis interface are multiplexed in each site, and the O&M signaling at different sites occupy the fixed TS on the Abis interface. At initialization, OMM reads ID signal from the rack top, and specifies TS of the BTS O&M information in the Abis interface according to the ID. For ID description, refer to DIP Switches and Jumpers.

Page 20: B8018 tecnical

ZXG10 B8018 (V1.00) In-Door Base Transceiver Station Technical Manual

8 Confidential and Proprietary Information of ZTE CORPORATION

The Abis interface has the following four types of TSs:

TCH TS for TRM service

Frame Unit LAPD (FUL) TS for TRM signaling

O&M TS for operation and maintenance signaling

EAM TS for transparent environment monitoring channel

Abis interface processing is as follows:

Transparently transmit the TCH, FUL, O&M and EAM between cascaded sites.

On the site, the processes are according to the direction of the signaling as follows:

Downlink:

TCH and FUL signaling are transmitted to each TRM transparently. The O&M transparently switches to OMC signaling according to Terminal Endpoint Identifier (TEI) and master rack transparently transmits the EAM signaling.

Uplink:

The TCH signaling is transmitted transparently. FUL signaling in the same cabinet is compressed and packed in the CMM. O&M signaling is multiplexed based on TEI, and master rack transparently transmits the EAM signaling.

System Structure

Figure 7 shows the system structure of ZXG10 B8018 (V1.00).

F I G U R E 7 – ZXG10 B8018 (V1 .00 ) S Y S T E M S T R U C T U R E

Page 21: B8018 tecnical

Confidential and Proprietary Information of ZTE CORPORATION 9

C h a p t e r 2

System Functions

This chapter introduces the system functions of ZXG10 B8018 (V1.00).

System Functions

Large system capacity and high performance

Capacity: 18 TRX/rack

Largest site type: O54 or S18/18/18

Support 6 cells

BTS power control: 6 levels static, 15 levels dynamic, 2 dB each step

Ability of cascades: Support 4-level cascaded networking

Compactness (smaller in size to make it appropriate for indoor installation).

Supports functions and channel encoding modes of

GPRS

EGPRS

CS1 - CS4

MCS1 - MCS9

Supports the following circuit-type voice services:

Full-rate voice service

Enhanced full-rate voice service

Half rate voice service

AMR voice service

Supports the following circuit-type data service:

9.6 kbps full-rate data service

4.8 kbps full-rate data service

Page 22: B8018 tecnical

ZXG10 B8018 (V1.00) In-Door Base Transceiver Station Technical Manual

10 Confidential and Proprietary Information of ZTE CORPORATION

2.4 kbps full-rate data service

GPRS/EDGE service

Ready for EDGE , GPRS (CS-1 to CS-4) and EGPRS(MCS1 to MCS9)

Compatible with the following standards:

GSM Phase I

GSM Phase II

GSM Phase II +

It adopts the GSM Phase II standard, capable of smooth upgrading to Phase II+.

Supports modules of different frequency bands in one cabinet.

Adjust the channel encoding mode dynamically according to the monitoring and measurement results.

Provides the following TCH services:

TCH/FS: Full-rate speech traffic channel

TCH/HS: Half-rate speech traffic channel

TCH/EFS: Enhanced full-rate speech traffic channel

AMR voice service

TCH/F9.6: 9.6 kbps full-rate data traffic channel

TCH/F4.8: 4.8 kbps full-rate data traffic channel

TCH/F2.4: 2.4 kbps full-rate data traffic channel

PDTCH: Supporting packet data service channels for GPRS and EGPRS of all encoding modes

Provides diversity reception

Space diversity

Frequency diversity

Time diversity

Polarization diversity

Supports GMSK and 8PSK modulation

System throughput: 384 kbps (48 kbps/timeslot) when mobile speed is between 3 kmph - 100 kmph and 144 kbps (18kbps/timeslot), when mobile speed up to 250 kmph.

High reliability, that is, automatic bridge circuit protection

High cost performance ratio

Comprehensive functions

Powerful service support capability (supporting GPRS/EGPRS)

Employ Dual Tranciever Unit (DTRU) technology. (Possess two carriers in each physical transceiver module)

Page 23: B8018 tecnical

Chapter 2 – System Functions

Confidential and Proprietary Information of ZTE CORPORATION 11

Support combined cabinet capacity expansion with ZXG10-BTS (V2)

Support 4-way diversity reception

Support 8 E1/T1 interface

Support 75 Ω/E1 and 120 Ω/E1 transmission

Support Tandem Free Operation (TFO) version 5

Possess advanced RF Technology

With double density TRX and advanced software radio technologies, the ZXG10 B8018 (V1.00) ensures the long-term reliability of the RF components, and improves the batch consistency and mass production of the equipment.

Adopts Viterbi soft decision algorithm at the receiving end

Improved channel decoding performance

Increased system receiving sensitivity

Anti-interference capability

Support frequency hopping. It improves the system capability against Rayleigh fading.

Supports Discontinuous Transmission (DTX):

Decreasing transmitter power

Lowering total interference level of air signals

Covers long coverage cells with a maximum of 120 kilometers in radius

Calculates Time Advance (TA)

A single cabinet supports 18 TRXs, and at maximum supports 54 TRXs at the same site. One site supports S18/18/18 configuration.

Provides common BCCH support, that is, same cell supports carrier frequency of two frequency bands sharing one BCCH.

Abis interface supports following networking modes:

Star

Chain

Tree

Ring

Flexible and reliable Abis interface

With the advanced flow control algorithm and variable rate signaling link technology, multiple logic signaling links can be configured flexibly on 64 Kbps physical link to fully share the bandwidth. 15 carriers can share one E1 line for transmission, and the multiplexing ratio is irrelevant to the site type.

Page 24: B8018 tecnical

ZXG10 B8018 (V1.00) In-Door Base Transceiver Station Technical Manual

12 Confidential and Proprietary Information of ZTE CORPORATION

Automatic crossover protection function provided for Abis interface link, if in case any ZXG10 B8018 (V1.00) is powered off in cascaded arrangement of BTSs.

Supports preprocessing of the measurement reports of the BTS.

Supports base station power control:

Static, level-6

Dynamical, level-15

Supports all paging modes specified in GSM

Supports different types of handovers:

Synchronous handover

Asynchronous handover

Pseudo-synchronous handover

Pre-synchronous handover

Um interface supports A51/A52 encryption algorithm.

Supports overall timely alarm system:

Supports fan alarms and internal cabinet temperature alarms.

Supports inputs for 10 pairs of external environment trunk nodes, and outputs for 2 pairs of trunk nodes.

Provides a transparent channel for operation and maintenance of the external intelligent equipment.

Supports unattended BTS and automatic alarm function.

Provides power supply and alarm for built-in tower amplifier system.

Provides Local Maintenance Terminal (LMT), facilitating commissioning, debugging and daily maintenance

Through the standard RS232 interface or RJ45 Ethernet interface, LMT can be connected to the equipment without dedicated cables. The LMT shares the same MMI as OMCR. Using the local maintenance gives an obvious view of the boards’ status with the lights and sound alarm to the operators. Extra safety is adopted in case of software version upgrade.

Support the following power compensation in Down-link:

Dual Power Combining Transmission (DPCT):

When seeking greater cell range, it is crucial to have a strong signal from the BTS to the handset. This is often referred to as downlink capability. The handset represents it as signal strength. In configurations intended for maximum coverage, DPCT doubles the output power from the BTS cabinet, resulting in a significantly larger coverage area.

Page 25: B8018 tecnical

Chapter 2 – System Functions

Confidential and Proprietary Information of ZTE CORPORATION 13

All power emissions are combined together to increase the emission at the antenna end.

The down-link signal power can be increased by 3 dB with combination.

Delay Diversity Transmission (DDT):

The signal in down-link is retransmitted in a specified symbols delay to avoid the related interferences. The delay period can be adjusted by operator with 0.125 symbol step within ±5 symbols. The terminal gathers two phases of radio signal, carrying the same information and take entire different interference as noise.

The down-link signal power can be increased by 3 dB by time-shifting.

Supports the following power compensation in Up-link

Interference Rejection Combining (IRC):

With the efforts of diversity antenna, BTS can get 11 dB gain in software simulation or 5~6 dB gain in typical downtown area. By using IRC, BTS should be equipped with at least two RX antennas.

Maximum Ratio Combining (MRC)

The BTS picks up the largest receiving power signal from RX. The DTRU compare received signals.

Equal Gain Combining (EGC): All the RX signals are amplified with the same index, and combined together.

Advanced IP based Abis Interface

The ZXG10 B8018 (V1.00) provides possibility of Abis interface over IP. It can be connected back over a wide variety of IP networks. This feature brings the advantage of the cost effective structure of IP based networks to the existing population of deployed handsets, maximizing the potential return for the operator.

Safe and agile power management subsystem

AI Power Control:

The system is capable to adjust the power requirements according to the present configuration and traffic demands. DTU is reconfigured automatically by partially switching off. This capability increases the life span of modules without any interference of system performances.

Page 26: B8018 tecnical

ZXG10 B8018 (V1.00) In-Door Base Transceiver Station Technical Manual

14 Confidential and Proprietary Information of ZTE CORPORATION

Advanced PS related feature

Keeping in sight the future evolutions and demands for the data service, all the PS related services, including NACC, Dynamic Abis, QoS alarm, and DTM are available in BS 8000 series production. These features offer extra stability and performance guarantee for the operators.

Page 27: B8018 tecnical

Confidential and Proprietary Information of ZTE CORPORATION 15

C h a p t e r 3

Technical Indices

This chapter describes the technical indices of ZXG10 B8018 (V1.00).

Working Bands

ZXG10 B8018 (V1.00) can support 900 MHz, extended 900 MHz, 850 MHz, 1800 MHz and 1900 MHz with different configurations along with variety of modules. Table 4 shows the working frequency bands.

T AB L E 4 – ZXG10 B8018 (V1 .00 ) W O R K I N G FR E Q U E N C Y B AN D S

Frequency Band Transmission Link Values

Uplink (transmitted by MS and received by BTS)

890 MHz - 915 MHz 900 MHz

Downlink (transmitted by BTS and received by MS)

935 MHz - 960 MHz

Uplink 880 MHz - 915 MHz Extended 900 MHz

Downlink 925 MHz - 960 MHz

Uplink 824 MHz – 849 MHz 850 MHz

Downlink 869 MHz – 894 MHz

Uplink 1710 MHz – 1785 MHz

1800 MHz

Downlink 1805 MHz – 1880 MHz

Uplink 1850 MHz – 1910 MHz

1900 MHz

Downlink 1930 MHz – 1990 MHz

Working Frequency

Bands

Page 28: B8018 tecnical

ZXG10 B8018 (V1.00) In-Door Base Transceiver Station Technical Manual

16 Confidential and Proprietary Information of ZTE CORPORATION

Interval between two adjacent channels in any band is 200 kHz.

All channels are configured with same interval. Table 5 shows the ZXG10 B8018 (V1.00) channel configuration.

T AB L E 5 – ZXG10 B8018 (V1 .00 ) CH AN N E L C O N F I G U R AT I O N

Frequency Band

Channel Number (n)

Frequency Calculation

900 MHz 1 – 124 = 124 Uplink : Fu (n) = 890 + 0.2 × n (MHz)

Downlink : Fd (n) = Fu(n) + 45 (MHz), 1 ≤ n ≤ 124

Extended 900 MHz

0 – 124 and 975 – 1023 = 174

Uplink :

Fu (n) = 890 + 0.2 × n (MHz), 0 ≤ n ≤ 124

Fu (n) = 890 + 0.2 × (n - 1024) (MHz), 975 ≤ n ≤ 1023

Downlink : Fd (n) = Fu (n) + 45 (MHz)

850 MHz 128 – 251 = 124

Uplink : Fu (n) = 824.2 + 0.2 × (n - 128) (MHz)

Downlink : Fd (n) = 869.2 + 0.2 × (n-128) (MHz), 128 ≤ n ≤ 251

1800 MHz 512 – 885 = 374

Uplink : Fu (n) = 1710.2 + 0.2 × (n - 512) (MHz)

Downlink : Fd (n) = Fu (n) + 95 (MHz), 512 ≤ n ≤ 885

1900 MHz 512 – 811 = 300

Uplink : Fu (n) = 1850.2 + 0.2 × (n - 512) (MHz)

Downlink : Fd (n) = Fu (n) + 80 (MHz), 512 ≤ n ≤ 811

Note: ‘n’ is a channel number or Absolute Radio Frequency Channel Number (ARFCN)

All frequency bands have duplex transceiver interval given in Table 6.

T AB L E 6 - D U P L E X TR AN S C E I V E R I N T E R V AL

Frequency Band Duplex Transceiver Interval

900 MHz 45 MHz

Extended 900 MHz 45 MHz

850 MHz 45 MHz

1800 MHz 95 MHz

1900 MHz 80 MHz

Channel Interval

Channel Configuration

Duplex Transceiver

Interval

Page 29: B8018 tecnical

Chapter 3 – Technical Indices

Confidential and Proprietary Information of ZTE CORPORATION 17

RF Indices

ZXG10 B8018 (V1.00) supports 40 W output for 8PSK and 60 W for GMSK.

The static receiving sensitivity of ZXG10 B8018 (V1.00) reaches up to -112 dBm. The high sensitivity guarantees the uplink channel performance and is one of the prerequisites for a wide coverage.

Physical Characteristics

Table 7 lists ZXG10 B8018 (V1.00) physical characteristics.

T AB L E 7 – ZXG10 B8018 (V1 .00 ) P H Y S I C AL C H AR AC T E R I S T I C S

Characteristics Parameters Values

Framework Section Aluminum Material Used

Doorplates Aluminum

Width 600 mm

Depth 550 mm

Dimensions

Height 1600 mm

Weight 270 kg (fully configured)

Color ZX-P02*02 Light Grey

Voltage and Power Consumption

Table 8 shows ZXG10 B8018 (V1.00) voltage and power consumption.

T AB L E 8 - ZXG10 B8018 (V1 .00 ) V O L T AG E AN D P O W E R C O N S U M P T I O N

Characteristics Parameters Values

Required working voltage

-48 V DC

-40 V DC (Maximum)

Voltage

Range

-57 V DC (Minimum)

3750 W (60 W) Power Consumption

3400 W (40 W)

The case of rack should be grounded well, with grounding resistance 5 Ω at most.

Output Power

High Receiving Sensitivity

Voltage and Power

Consumption Chart

Grounding Resistance

Page 30: B8018 tecnical

ZXG10 B8018 (V1.00) In-Door Base Transceiver Station Technical Manual

18 Confidential and Proprietary Information of ZTE CORPORATION

Heat Dissipation

Heat dissipation in the rack is from TRM and AEM in the carrier plug-in shelf.

Table 9 shows ZXG10 B8018 (V1.00) heat dissipation of each module.

T AB L E 9 – ZXG10 B8018 (V1 .00 ) HE AT D I S S I P AT I O N

Characteristics Parameters Values

TRM (×18) 120 W per TRM

ETRM 135 W per ETRM

AEM (×9) 45 W per AEM

CMM (×2) 20 W per CMM

Heat dissipation (full configuration of each carrier shelf: 600 W)

Fan (×3) 30 W per Fan

Heat dissipation in full configuration is as below:

Without ETRM, heat dissipation of integrated equipment is less than 2200 W

With ETRM, heat dissipation of integrated equipment is less than 2350 W

Environmental Characteristics

Table 10 shows ZXG10 B8018 (V1.00) environmental characteristics.

T AB L E 10 – ZXG10 B8018 (V1 .00 ) E N V I R O N M E N T AL C H AR AC T E R I S T I C S

Characteristics Parameters Values

Minimum -5 °C Temperature

Maximum 45 °C

Minimum 15 % Humidity (No Condensation)

Maximum 90 %

Avoid direct sunshine to prevent the circuit boards and other components from aging and deforming. The average illumination should be 300 Lx - 450 Lx.

Erosive gases, smog, and smoking are prohibited in the equipment room.

Inner Illumination

Air Pollution

Page 31: B8018 tecnical

Chapter 3 – Technical Indices

Confidential and Proprietary Information of ZTE CORPORATION 19

Capacity

A single rack of ZXG10 B8018 (V1.00) supports 9 DTRUs, and 18 carrier frequencies when fully configured. A single cabinet supports the maximum site configuration S6/6/6.

A single site supports 3 cabinets and 54 carriers.

Clock

ZXG10 B8018 (V1.00) provides a two-level clock, whose specifications are given in Table 11.

T AB L E 11 – ZXG10 B8018 (V1 .00 ) CL O C K S P E C I F I C AT I O N S

Characteristics Values

Clock accuracy ± 1.0 × 10-7

Pull-in range ± 1.0 × 10-9

Maximum frequency bias 1 × 10-9 / day

Initial maximum frequency bias 1 × 10-7

Reliability

The product successfully passed the CE certification. It complies with international standards related to personal safety, electromagnetic security (EMC) and wireless frequency spectrum.

Table 12 explains the specifications.

T AB L E 12 – ZXG10 B8018 (V1 .00 ) R E L I AB I L I T Y S P E C I F I C AT I O N S

Characteristics Values

Mean Time Between Failures (MTBF) ≥100000 hours

Mean Time to Repair (MTTR) 34 min. 12 sec.

Availability Ratio (A) 99.9991 %

Average Interruption time per year 4 min. 48 sec.

Interface Specifications

Abis interface adopts standard E1 interface. The performance of Abis interface meets the requirements specified by ITU-T G.703 and ITU-T G.704 given below:

Abis Interface Specification

Page 32: B8018 tecnical

ZXG10 B8018 (V1.00) In-Door Base Transceiver Station Technical Manual

20 Confidential and Proprietary Information of ZTE CORPORATION

Basic requirements

The basic requirements of Abis interface are shown in Table 13.

T AB L E 13 - AB I S I N T E R F AC E B AS I C R E Q U I R E M E N T S

Basic Requirements Values

Approximate bit rate 2048 Kbps

Bit rate tolerance ± 50 × 10-6

Signal code pattern HDB3

Page 33: B8018 tecnical

Chapter 3 – Technical Indices

Confidential and Proprietary Information of ZTE CORPORATION 21

Electrical features

The electrical features of Abis interface are shown in Table 14

T AB L E 14 - AB I S I N T E R F AC E E L E C T R I C AL FE AT U R E S

Electrical Features Values

Pulse Shape Rectangular

Approximate pulse duration

244 ns

2.37 V (75 Ω for pair coaxial cable)

Approximate peak voltage of pulse (mark)

3 V (120 Ω for pair symmetrical cables)

0 ± 0.237 V (75 Ω for pair of coaxial cables)

Peak voltage when without pulse (vacant number)

0.3 V (120 Ω for pair of symmetrical cables)

At midpoint of pulse width: > 0.955 - 1.05

Amplitude ratio between positive pulse and negative pulse

At half of approximate pulse amplitude: > 0.95 - 1.05

1.5 UI (peak-peak value, 20 Hz - 100 kHz)

Digital signal jittering features (1 UI = 488 ns)

0.2 UI (peak-peak value, 18 Hz - 100 kHz

2.5% - 5% (when it is 51.2 Kbps - 102.4 Kbps, echo attenuation ≥ 12 dB)

5% - 100% (when it is 102.4 Kbps - 2048 Kbps, echo attenuation ≥ 18 dB)

Input Impedance features

100% - 150% (when it is 2048 Kbps - 3072 Kbps, echo attenuation ≥ 14 dB)

Main specifications are as follows:

Wireless Channel

Co-channel interference protection ratio: C/I ≥ 9 dB (static)

Interference protection ratio of the adjacent channels: ≥ -9 dB

Interference protection ratio of the second adjacent channel: ≥ -43 dB

Wireless channel selection adopts shared signaling channel mode

Um Interface Specification

Page 34: B8018 tecnical

ZXG10 B8018 (V1.00) In-Door Base Transceiver Station Technical Manual

22 Confidential and Proprietary Information of ZTE CORPORATION

Wireless RF modulation mode

Adopts GMSK to perform modulation. BT = 0.3 and the modulation coefficient is 1.35.

Transmitter Performance

Transmitter phase error

Phase error of the transmitter is the error between actual phase and theoretical phase.

Root mean square (RMS) of BTS phase error ≤ 5o and peak value ≤ 20o.

Transmitter frequency error

Frequency error of the transmitter is the error between actual frequency and the theoretical frequency.

BTS frequency error ≤ 0.05 ppm

Average transmitted carrier power (requirement for the power amplifier output)

There is a 6-level static power control function. It can adjust downwards six power levels with the step of 2 dB ± 1.0 dB, based on the maximum output power. At the same time, BTS has the downlink power-control function. It can decrease the power from level 0 to level 15 with the step of 2 dB ± 1.5 dB, based on the set power level.

Specifications compliant with GSM 11.21 and GSM 05.05 are as follows:

Transmitted RF carrier power/time envelope

Inter-modulation attenuation of transmitter

Inter-modulation attenuation in BSS

Transmitted adjacent channel power

Spurious emission of transmitter

Receiver Performance

The following characteristics describe the receiver performance, which comply with GSM 11.21 and GSM 05.05:

Static layer-1 receiver function (approximate bit error rate) before channel decoding, which includes the following:

Multiplexing and multi-addressing

Equalizer decryption

De-interleaving

Channel encoding

Page 35: B8018 tecnical

Chapter 3 – Technical Indices

Confidential and Proprietary Information of ZTE CORPORATION 23

Static referential sensitivity level:

A level set while inputting a standard test signal under the static environment. The FER, RBER or BER, generated after modulation and channel decoding, meets the specified requirements when the level is configured as the referential sensitivity level. Static sensitivity levels for reference of GMSK & 8PSK are as follows:

GMSK: ≤ -108 dBm

8PSK: ≤ - 104 dBm

Multi-path referential sensitivity:

A level set while inputting a standard test signal under the multi-path environment. The FER, RBER or BER, generated after modulation and channel decoding, meets the specified requirements when the level is configured as the referential sensitivity level.

Referential interference level (interference and suppression of same frequency and adjacent channels) is the capability to receive the expected modulation signal not over given degraded quantity. It is caused by unexpected modulation signal on same carrier frequency (interference of same channel) or any adjacent carrier frequency (interference of adjacent channel).

Block and spurious response suppression

Test the capability that BSS receiver receives the GSM modulation signal when interfering signal exists.

Inter-modulation suppression

It is used for linear degree measurement of RF part of receiver. It indicates the receiver’s capability of receiving good-quality expected modulation-signal, when two or multiple unexpected signals exist, which are similar to the expected signal in frequency.

AM suppression

It is the capability of receiving the expected modulation signals, below the given degraded quantity when an unexpected modulation signal exists.

Spurious emission

It is the emission of frequencies other than that used by RF channel of receiver and adjacent frequencies.

Page 36: B8018 tecnical

ZXG10 B8018 (V1.00) In-Door Base Transceiver Station Technical Manual

24 Confidential and Proprietary Information of ZTE CORPORATION

This page is intentionally blank.

Page 37: B8018 tecnical

Confidential and Proprietary Information of ZTE CORPORATION 25

C h a p t e r 4

Structure and Principle

This chapter describes the hardware and software structure and system working principle of ZXG10 B8018 (V1.00).

Hardware Cabinet

Figure 8 shows the ZXG10 B8018 (V1.00) cabinet.

F I G U R E 8 – ZXG10 B8018 (V1 .00 ) C AB I N E T

Cabinet Appearance

Page 38: B8018 tecnical

ZXG10 B8018 (V1.00) In-Door Base Transceiver Station Technical Manual

26 Confidential and Proprietary Information of ZTE CORPORATION

Figure 9 shows the single cabinet with full configuration

F I G U R E 9 - S I N G L E C AB I N E T W I T H FU L L C O N F I G U R AT I O N

Cabinet with Full

Configuration

Page 39: B8018 tecnical

Chapter 4 – Hardware Components Introduction

Confidential and Proprietary Information of ZTE CORPORATION 27

Clock Distribution

There are two main functions of clock system:

Clock synchronization

Clock distribution

The system can work in free oscillation or network synchronization mode. The processing of 13 MHz clock synchronization is the same as in ZXG10-BTS (V2.0). However, in ZXG10 B8018 (V1.00), radio clock can work in free oscillation or synchronize with the ground transmission network. If system radio clock is configured for network synchronization, the system transmission clock should also be configured for network synchronization.

There are two types of Abis interface in B8018 system:

E1/T1 interface

100 Mbps Ethernet interface

The system can work in free oscillation as well as network synchronization mode for both types of Abis interfaces. If the Abis interface is E1/T1, in network synchronization, both 2 MHz and 8 KHz synchronization clocks can be obtained. However, in the case of 100 Mbps Ethernet Abis interface, the 8 kHz synchronization can only be obtained from 2 MHz clock.

The clock transmission in the internal system is implemented through LVDS.

Clock from CMB to DTRU includes 13 MHz, 60 ms synchronization signal, 8 MHz, and 8K_8MW. The system clock distribution in the rack of ZXG10 B8018 (V1.00), distributes from CMB to DTRU, employs point-to-multipoint bus LVDS for the same carrier frequency frame. This is shown in Figure 10. The clock is delivered to each carrier frequency frame through differential bus, and each DTRU of the same carrier frequency frame gets clock from the same bus.

The 60 ms synchronization is to combine cabinet capacity expansion, and the frame number is transmitted via E1. If 60 ms synchronization signal is used in combined cabinet capacity expansion, it includes receiving 60 ms synchronization signal from main rack or sending 60 ms synchronization signal to secondary rack.

Page 40: B8018 tecnical

ZXG10 B8018 (V1.00) In-Door Base Transceiver Station Technical Manual

28 Confidential and Proprietary Information of ZTE CORPORATION

F I G U R E 10 – C L O C K D I S T R I B U T I O N I N ZXG10 B8018 (V1 .00)

Time Slot Switching

Figure 11 shows the time slot switching in ZXG10 B8018 (V1.00).

F I G U R E 11 – T I M E S L O T SW I T C H I N G I N ZXG10 B8018 (V1 .00)

CMB

FIB

8*E1/T1

100M ETH

MT90826

8MHW

EIB 8*E1/T1

CPU

QMC

4*2MHW

4*2MHW

4*2MH

W

8MHW

8MHW

8MHW

LAY

ER 1

LAY

ER 2

LAY

ER 3

Environment Monitoring

(Transparent Message)

2 MHW

2 MHW

2 MHW

8*2M

HW

4*2M

HW

Rate

Conversion

E1/T1Fram

er&LIU

Rate

Conversion

Rate

Conversion

Rate

Conversion

dTRU

(#0-2)dTR

U(#3-5)

dTRU

(#6-8)

Service data switching is implemented in CMB in ZXG10 B8018 (V1.00) system. When Abis interface is E1/T1, CMB receives the service data, and operation and maintenance data from BSC, and switches it to each DTRU of the rack, auxiliary rack or cascaded site through 2 bit switching network.

Page 41: B8018 tecnical

Chapter 4 – Hardware Components Introduction

Confidential and Proprietary Information of ZTE CORPORATION 29

Overall Hardware Structure

The rack is divided into several functional parts. These parts are located in four shelves. The shelf layout inherits the tradition in ZXG10 series.

The interface module, control module and power distribution parts are concentrated at the top of the rack.

E1/T1 Interface Board (EIB) is dedicated for the interface to provide E1/T1 interface.

Fast Ethernet Interface Board (FIB) is an optional module to meet further IP backbone demands.

The rest of three shelves are dedicated for the transceiver and antenna distribution modules.

The combiner module can be configured as required to form S 18/18/18 sites or O54.

Figure 12 shows the rack layout.

F I G U R E 12 – R AC K L AY O U T

Page 42: B8018 tecnical

ZXG10 B8018 (V1.00) In-Door Base Transceiver Station Technical Manual

30 Confidential and Proprietary Information of ZTE CORPORATION

ZXG10 B8018 (V1.00) hardware structure is shown in Figure 13.

F I G U R E 13 – ZXG10 B8018 (V1 .00 ) H AR D W AR E S T R U C T U R E

Page 43: B8018 tecnical

Chapter 4 – Hardware Components Introduction

Confidential and Proprietary Information of ZTE CORPORATION 31

Function Description of each part of the cabinet is given in Table 15.

T AB L E 15 - FU N C T I O N D E S C R I P T I O N S O F H AR D W AR E P AR T S

Module Description

EIB/FIB EIB supports E1/T1 interface.

FIB supports 100BASE-T interface.

CMB CMB provides the basic operation and central control for the BTS including alarm control, synchronization, radio resource control etc.

DTRU Providing all the radio functions related with terminal communication.

DTRU module consists of four parts: DTPB, DPB, DPAB and DRCB.

AEM AEM is in charge of combining several TX signals towards antenna, including CDU, ECDU, CEUT.

PDM PDM provides the power distribution function.

Software Software Structure

The ZXG10 B8018 (V1.00) software consists of the following main subsystems:

dCMM software subsystem

dFUC software subsystem

dCHP software subsystem

FIU software subsystem (optional)

Figure 14 shows the basic software structure of ZXG10 B8018 (V1.00).

Function Description

Page 44: B8018 tecnical

ZXG10 B8018 (V1.00) In-Door Base Transceiver Station Technical Manual

32 Confidential and Proprietary Information of ZTE CORPORATION

F I G U R E 14 – ZXG10 B8018 (V1 .00 ) S O F T W AR E S T R U C T U R E

dCMM software sub-system takes charge of the system initialization after power on. It downloads all board software and operation and maintenance management system.

dFUC and dCHP software sub-system take charge of service processing, baseband signal processing, and operation and maintenance on this board.

FIU software sub-system is responsible for the connection with BSC, working flow control of board, resource configuration management, and operation and maintenance management.

All board software run on respective CPU of each board. The communication among boards is implemented by HDLC communication protocol, and all board softwares are installed in pSOS (V2.0) operation system from WindRiver.

dCMM software block diagram is shown in Figure 15.

F I G U R E 15 – D CMM B L O C K D I AG R AM

dCMM Software Sub-

system

Page 45: B8018 tecnical

Chapter 4 – Hardware Components Introduction

Confidential and Proprietary Information of ZTE CORPORATION 33

The dCMM software sub-system serves the following functions:

Performs remote operation maintenance of BTS of the relevant sub-system. These functions includes the following:

Parameters configuration

Management of status and alarms

Management of each software version

Equipment test

Provides local operation maintenance function to make on-site commissioning convenient.

Provides alarm collection and management of external equipment to collect the state and alarm of the equipment that cannot communicate with CMM directly.

Provides intelligent power ON/OFF management to BTS equipment.

Synchronize the frame number and clock in one site.

Increases the reliability of the system by employing active/standby hot backup in dCMM module (backup includes static configuration parameters and frame number). This makes sure that the service and signaling channels of dTRM module are in good status during active/standby dCMM switching. It helps the frame number of each TRM in the BTS to synchronize with the whole site.

Provides interface function of the site. For example, the multiplexing of physical time slot and to provide transparent passage for some external equipment.

Provides a series of debugging and test tools for error diagnosis and location.

Baseband processing unit with DTPB is called dCHP for short. Thin Chip Integration (TCI) 100 DSP device is the hardware platform for dCHP. There is one DSP chip on each DTPB.

Main functions of dCHP software sub-system are as follows:

Demodulation of baseband dual carrier IQ signal, supporting equalization demodulation of GMSK and 8PSK

Baseband supports two and four-way diversities reception and transmission in DPCT mode

Baseband measurement module, implementing calculation of C/I of radio channel

Baseband synchronization module, implementing calculation of TA

Channel coding/decoding, supporting CS service HR/FR/EFR/AMR and PS service CS1-4/MCS1-9

Protocol processing of uplink and down link

dCHP Software

Sub-system

Page 46: B8018 tecnical

ZXG10 B8018 (V1.00) In-Door Base Transceiver Station Technical Manual

34 Confidential and Proprietary Information of ZTE CORPORATION

Processing of rate adaptation

Message processing at HPI interface

DSP/BIOS dispatch of operation system, implementing sequence control of baseband assignment

Baseband monitoring processing module, providing baseband alarm reporting and test debugging function

Baseband power control

dFUC software block diagram is shown in Figure 16.

F I G U R E 16 – D FUC S O F T W AR E B L O C K D I AG R AM

无线资源管理

寻呼与接入管理

操作维护

版本控制

设备管理

DFUC软件子系统

功率控制

Operation and Maintenance

Radio Resource Management

Version Control Power Control

Equipment Management

Paging and Access Management

dFUC Software Sub-system

dFUC software sub-system provides the following functions:

Circuit Switching (CS) Service

Manages radio resource: Complete processing of all messages at 3GPP 08.58 Abis interface and part of the radio resource management message at 3GPP 04.08 Um interface.

Calculates TA

Pre-processing by measurement report to decrease the signaling flux at Abis interface to satisfy the 16 Kbps transmission of LAPD.

Support power control of MS and BTS

Packet Switching (GPRS or PS) Service

Assist BSC to implement part of functions of RLC/MAC module, and process the message on PBCCH and PRACH.

Calculate TA of MS on Packet Timing Control Channel (PTCCH)

Support dynamic configuration of PS/CS of physical channel

dFUC Software Sub-system

Page 47: B8018 tecnical

Chapter 4 – Hardware Components Introduction

Confidential and Proprietary Information of ZTE CORPORATION 35

Manage dCHP

Load software used by dFUC, dCHP and FPGA, manage software version

Parameter configuration and state management of dFUC and dCHP

Alarm collection and report of dTRM unit

Performance Test

Support performance test item of BTS, for example number of lost paging messages, occupation time of maximum power level etc.

Monitor running state dynamically of local and dCHP object by local operation and maintenance.

FIU software block diagram is shown in Figure 17.

F I G U R E 17 - F IU S O F T W AR E S U B -S Y S T E M B L O C K D I AG R AM

FIU software sub-system provides following functions:

Mapping from downlink Ethernet IP packet to time slot and communicate with CMB by 8MHW

Save uplink E1 signal and combine as IP packet to report BSC

Implement and read various hardware management IDs of system: layer number, slot number, board type, and hardware version of board and so on to achieve mapping of MAC address of each board.

FIU Software Sub-system

Page 48: B8018 tecnical

ZXG10 B8018 (V1.00) In-Door Base Transceiver Station Technical Manual

36 Confidential and Proprietary Information of ZTE CORPORATION

System Working Principle The working principle of ZXG10 B8018 (V1.00) is shown in Figure 18.

F I G U R E 18 - ZXG10 B8018 (V1 .00 ) S I G N AL I N G FL O W

Con

troller &

M

ainten

ance U

nit

Baseb

and

Pro

cessor

RF U

nit

BSC

Abis In

terface

Data Link

System Clock

Baseband Modulated

Signal

RF Demodulation

Signal

Control Signal

System Clock

RF Signal

Power Distribution Module

-48V or +24VDC

Anten

na Feed

er Pro

cessor

Um Interface

ZXG10 B8018 (V1.00) system includes following units:

Controller & Maintenance Unit

Baseband Processor

RF Unit

Antenna Feeder Processor

Power Distribution Module (PDM)

Working principle is as follows:

Downlink:

i. BTS receives data from BSC, including voice and signaling data.

ii. Control & maintenance unit receives signaling data for processing.

iii. Base band processor receives voice data for processing such as rate conversion, encryption, and interleaving.

iv. Voice is sent to RF unit where it is modulated to High frequency signals.

v. The signals are then transmitted via the antenna feeder processor.

Page 49: B8018 tecnical

Chapter 4 – Hardware Components Introduction

Confidential and Proprietary Information of ZTE CORPORATION 37

Uplink:

i. Antenna feeder processor receives RF signals from MS.

ii. The signals are then transmitted to the RF unit to convert them into digital signals.

iii. Data is sent to the base band processor for rate conversion, decryption, and de-interleaving.

iv. After conversion to suitable code pattern for long-distance transmission, the signals are sent to BSC through the Abis interface.

Page 50: B8018 tecnical

ZXG10 B8018 (V1.00) In-Door Base Transceiver Station Technical Manual

38 Confidential and Proprietary Information of ZTE CORPORATION

This page is intentionally blank.

Page 51: B8018 tecnical

Confidential and Proprietary Information of ZTE CORPORATION 39

C h a p t e r 5

Hardware Components Introduction

Cabinet Composition

The cabinet consists of the main body, doors, top, base, and several shelves.

The main body of the cabinet is a whole welded from columns, shell, bottom, and top.

Figure 19 shows the structure of the cabinet.

F I G U R E 19 – C AB I N E T S T R U C T U R E

1: Rear door 5: Carrier shelf 9: Cabinet main body

2: Cabinet top 6: Side baffle 10: Base

3: Top shelf and PDM 7: Front door 11: Air filter shelf

4: Fan shelf 8: Horizontal cabling rack

Exploded View

Page 52: B8018 tecnical

ZXG10 B8018 (V1.00) In-Door Base Transceiver Station Technical Manual

40 Confidential and Proprietary Information of ZTE CORPORATION

Cabinet Top Cabinet Top Structure

The top of ZXG10 B8018 (V1.00) cabinet is used to install antennas, power switches, filters, grounding posts/sockets, and other sockets. Holes are designed on the back of the cabinet top as hot air outlets.

The layout of the cabinet top is shown in Figure 20.

F I G U R E 20 - CAB I N E T TO P LAY O U T

1: PE 9: E1 PORT 17: HYCOM6

2: PWRTA_L1 10: RELAY_ALM 18: HYCOM7

3: PWRTA_L2 11: ID PORT 19: HYCOM8

4: PWRTA_L3 12: HYCOM1 20: HYCOM9

5: 13 MHz Clock 13: HYCOM2 21: HYCOM10

6: FCLK 14: HYCOM3 22: HYCOM11

7: RJ45 15: HYCOM4 23: HYCOM12

8: E1 PORT 16: HYCOM5

The interfaces on the cabinet top are shown in Table 16.

Page 53: B8018 tecnical

Chapter 5 – Hardware Components Introduction

Confidential and Proprietary Information of ZTE CORPORATION 41

T AB L E 16 - IN T E R F AC E S O N T H E C AB I N E T TO P

Interface Name

Socket Type Description

HYCOM1 – HYCOM12

7/16'' female socket Antenna feeder interface

PWRTA_L1 DB9 male socket Power interface of the first layer of tower mounted amplifier

PWRTA_L2 DB9 male socket Power interface of the second layer of tower mounted amplifier

PWRTA_L3 DB9 male socket Power interface of the third layer of tower mounted amplifier

E1 PORT DB25 male socket E1 interface

RELAY_ALM DB25 male socket Main contact point alarm interface

ID PORT DB25 male socket Site ID interface

13M BNC female socket 13M clock test interface

FCLK BNC female socket FCLCK clock test interface

PE - Grounding post

RJ45 - RJ45 interface

Cabinet Top Interfaces

The ZXG10 B8018 (V1.00) uses –48 V DC power.

The primary power is introduced from the power interface on the cabinet top.

The interface between primary power and the BTS equipment is described in Table 17.

T AB L E 17 - PR I M AR Y P O W E R I N T E R F AC E S I G N AL D E S C R I P T I O N

Pin-outs and Signals

No. Signal Name End A End B

Signal Definition

PWR External -48 VDC

-48 VDC

1 External power input cable GND

External power ground

Power ground

Interface between

Primary Power and BTS

Equipment

Page 54: B8018 tecnical

ZXG10 B8018 (V1.00) In-Door Base Transceiver Station Technical Manual

42 Confidential and Proprietary Information of ZTE CORPORATION

The antenna feeder interface transmits RF carrier signals between BTS and MS.

One BTS cabinet supports six suites of TX/RX antennas.

There are six antenna feeder interfaces on the top of each BTS cabinet: HYCOM1 - HYCOM6.

HYCOM1, HYCOM4: Antenna feeder interfaces of the AEMs in the third carrier shelf.

HYCOM2, HYCOM5: Antenna feeder interfaces of the AEMs in the second carrier shelf.

HYCOM3, HYCOM6: Antenna feeder interfaces of the AEMs in the first carrier shelf.

Connector: 7/16'' female socket.

The PWRTA interface is located on the cabinet top. Each BTS cabinet provides three such interfaces: PWRTA_1 to PWRTA_3.

The signals of PWRTA_1 are defined in Table 18

T AB L E 18 - S I G N AL D E S C R I P T I O N O F PWRT A_1

Pin-outs and Signals N

o.

Signal N

ame

End A

End B

Signal

Defin

ition

Con

nector

Cable

Requ

iremen

ts

1 TMA power

TA_PWR1 - TMA power 1

2 - - - -

3 TMA power

AGND - Analog ground

4 - - - -

5 TMA power

TA_PWR0 - TMA power 0

6 TMA power

TA_PWR1 - TMA power 1

7 TMA power

AGND - Analog ground

8 - - - -

9 TMA power

TA_PWR0 - TMA power 0

DB9 SYV-50-1

The signals of PWRTA_2 are defined in Table 19.

Antenna Feeder

Interface

Tower Mounted Amplifier Interface (PWRTA)

Page 55: B8018 tecnical

Chapter 5 – Hardware Components Introduction

Confidential and Proprietary Information of ZTE CORPORATION 43

T AB L E 19 - S I G N AL D E S C R I P T I O N O F PWRT A_2

Pin-outs and Signals

No

.

Sig

nal N

am

e

En

d A

En

d B

Sig

nal

Defin

ition

Co

nn

ecto

r

Cab

le

Req

uire

men

ts

1 TMA power

TA_PWR1 - TMA power 1

2 - - - -

3 TMA power

AGND - Analog ground

4 - - - -

5 TMA power

TA_PWR0 - TMA power 0

6 TMA power

TA_PWR1 - TMA power 1

7 TMA power

AGND - Analog ground

8 - - - -

9 TMA power

TA_PWR0 - TMA power 0

DB9 SYV-50-1

The signals of PWRTA_3 are defined in Table 20.

T AB L E 20 - S I G N AL D E S C R I P T I O N O F PWRT A_3

Pin-outs and Signals

No

.

Sig

nal N

am

e

En

d A

En

d B

Sig

nal

Defin

ition

Co

nn

ecto

r

Cab

le

Req

uire

men

ts

1 TMA power

TA_PWR1 - TMA power 1

2 - - - -

3 TMA power

AGND - Analog ground

4 - - - -

5 TMA power

TA_PWR0 - TMA power 0

6 TMA power

TA_PWR1 - TMA power 1

7 TMA power

AGND - Analog ground

8 - - - -

DB9 SYV-50-1

Page 56: B8018 tecnical

ZXG10 B8018 (V1.00) In-Door Base Transceiver Station Technical Manual

44 Confidential and Proprietary Information of ZTE CORPORATION

Pin-outs and Signals

No

.

Sig

nal N

am

e

En

d A

En

d B

Sig

nal

Defin

ition

Co

nn

ecto

r

Cab

le

Req

uire

men

ts

9 TMA power

TA_PWR0 - TMA power 0

The BTS cabinet top provides a PE interface directly connected with the protection ground of the equipment room. All digital grounds, analog grounds, and protection grounds inside the cabinet are grounded to the PE interface and the equipment room ground.

Signal: 13 M reference clock

Connector: BNC female

Quantity: One per cabinet

Signal: System frame clock

Line signal: TTL level

Connector: BNC female

The external environment monitoring equipment provides two kinds of interfaces:

RS232 serial ports

Main contact points for reflecting the alarm status

On the top of the ZXG10 B8018 (V1.00) cabinet, DB25 male connectors are designed to connect alarm status signals from the main contact points. The cabinet supports the inputs of at most ten pairs of main contact points and the outputs of at most two pairs of main contact points.

Grounding Interface (PE)

13 M Test Interface

FCLK Test Interface

External Environment

Monitoring Interface

RELAY_ALM

Page 57: B8018 tecnical

Chapter 5 – Hardware Components Introduction

Confidential and Proprietary Information of ZTE CORPORATION 45

The main contact point signal interface is defined in Table 21.

T AB L E 21 - S I G N AL D E S C R I P T I O N O F T H E M AI N C O N T AC T P O I N T S I G N AL I N T E R F AC E

Pin-outs and Signals

No

.

Sig

nal

Nam

e

En

d A

En

d B

Sig

nal

Defin

ition

Co

nn

ecto

r

1 ALM_IN0+ Main contact point input and pull-up resistor

2 ALM_IN0-

Main contact point input and pull-down resistor, connected to the I/O port

3 ALM_IN1+ Main contact point input and pull-up resistor

4 ALM_IN1-

Main contact point input and pull-down resistor, connected to the I/O port

5 ALM_IN2+

Main contact point input and pull-up resistor

6 ALM_IN2-

Main contact point input and pull-down resistor, connected to the I/O port

7 ALM_IN3+ Main contact point input and pull-up resistor

8 ALM_IN3-

Main contact point input and pull-down resistor, connected to the I/O port

9 ALM_IN4+ Main contact point input and pull-up resistor

10 ALM_IN4-

Main contact point input and pull-down resistor, connected to the I/O port

11 ALM_IN5+ Main contact point input and pull-up resistor

12 ALM_IN5-

Main contact point input and pull-down resistor, connected to the I/O port

13 DGND Digital ground

14

Main contact Points

ALM_IN6+

-

Main contact point input and pull-up resistor

DB25

Page 58: B8018 tecnical

ZXG10 B8018 (V1.00) In-Door Base Transceiver Station Technical Manual

46 Confidential and Proprietary Information of ZTE CORPORATION

Pin-outs and Signals

No

.

Sig

nal

Nam

e

En

d A

En

d B

Sig

nal

Defin

ition

Co

nn

ecto

r

15 ALM_IN6-

Main contact point input and pull-down resistor, connected to the I/O port

16 ALM_IN7+ Main contact point input and pull-up resistor

17 ALM_IN7-

Main contact point input and pull-down resistor, connected to the I/O port

18 ALM_IN8+ Main contact point input and pull-up resistor

19 ALM_IN8-

Main contact point input and pull-down resistor, connected to the I/O port

20 ALM_IN9+ Main contact point input and pull-up resistor

21 ALM_IN9-

Main contact point input and pull-down resistor, connected to the I/O port

22 ALM_OUT0+

Main contact point output, connected to the output of the normally open relay

23 ALM_OUT0-

Main contact point output, connected to the output of the normally open relay

24 ALM_OUT1+

Main contact point output, connected to the output of the normally open relay

25 ALM_OUT1-

Main contact point output, connected to the output of the normally open relay

There is a D connector on the top of each ZXG10 B8018 (V1.00) cabinet. Inside this connector, there is a circuit board with a DIP switch used to set the site ID.

The site ID interface is described in Table 22.

Site ID Interface

Page 59: B8018 tecnical

Chapter 5 – Hardware Components Introduction

Confidential and Proprietary Information of ZTE CORPORATION 47

T AB L E 22 - S I T E ID I N T E R F AC E S I G N AL D E S C R I P T I O N

Pin-outs and Signals

No

.

Sig

nal N

am

e

En

d A

En

d B

Sig

nal

Defin

ition

Co

nn

ecto

r

1 ID0 Bit 0 of the site ID

2 ID1 Bit 1 of the site ID

3 ID2 Bit 2 of the site ID

4 ID3 Bit 3 of the site ID

5 ID4 Bit 4 of the site ID

6 ID5 Bit 5 of the site ID

7 ID6 Bit 6 of the site ID

8 ID7 Bit 7 of the site ID

9 ID8 Bit 8 of the site ID

10 ID9 Bit 9 of the site ID

11 ID10 Bit 10 of the site ID

12 ID11 Bit 11 of the site ID

13 ID12 Bit 12 of the site ID

14 ID13 Bit 13 of the site ID

15 ID14 Bit 14 of the site ID

16 ID15 Bit 15 of the site ID

17

Sig

nals o

f the S

ite ID in

terface

DGND

-

Digital ground

DB25

In the ZXG10 B8018 (V1.00), the Abis interface and the inter-cabinet cascaded interfaces all use E1 interfaces.

The signals of the E1 interface are defined in Table 23.

T AB L E 23 - E1 I N T E R F AC E S I G N AL D E S C R I P T I O N

Pin-outs and Signals

No

.

Sig

nal N

am

e

En

d A

En

d B

Sig

nal

Defin

ition

Co

nn

ecto

r

1 A_IN+ E1_A interface signal input

2 B_IN+ E1_B interface signal input

3 C_IN+ E1_C interface signal input

4 D_IN+ E1_D interface signal input

5

E1 sig

nals

E_IN+

-

E1_E interface signal input

DB25

E1 Interface

Page 60: B8018 tecnical

ZXG10 B8018 (V1.00) In-Door Base Transceiver Station Technical Manual

48 Confidential and Proprietary Information of ZTE CORPORATION

Pin-outs and Signals

No

.

Sig

nal N

am

e

En

d A

En

d B

Sig

nal

Defin

ition

Co

nn

ecto

r

6 F_IN+ E1_F interface signal input

7 DGND Digital ground

8 A_OUT+ E1_A interface signal output

9 B_OUT+ E1_B interface signal output

10 C_OUT+ E1_C interface signal output

11 D_OUT+ E1_D interface signal output

12 E_OUT+ E1_E interface signal output

13 F_OUT+ E1_F interface signal output

14 A_IN- E1_A interface signal input

15 B_IN- E1_B interface signal input

16 C_IN- E1_C interface signal input

17 D_IN- E1_D interface signal input

18 E_IN- E1_E interface signal input

19 F_IN- E1_F interface signal input

20 A_OUT- E1_A interface signal output

21 B_OUT- E1_B interface signal output

22 C_OUT- E1_C interface signal output

23 D_OUT- E1_D interface signal output

24 E_OUT- E1_E interface signal output

25 F_OUT- E1_F interface signal output

LVDS lines are used between ZXG10 B8018 (V1.00) cabinets to transmit the synchronization clock (SYNCLK).

Physically, a twisted pair with D connectors is used as the differential line.

Inter-rack Synchronization Signal Interface

(SYNC)

Page 61: B8018 tecnical

Chapter 5 – Hardware Components Introduction

Confidential and Proprietary Information of ZTE CORPORATION 49

The inter-cabinet synchronization signal interface is defined in Table 24.

T AB L E 24 - I N T E R -C AB I N E T S Y N C H R O N I Z AT I O N S I G N AL I N T E R F AC E S I G N AL D E S C R I P T I O N

Pin-outs and Signals

No

.

Sig

nal N

am

e

En

d A

En

d B

Sig

nal

Defin

ition

Co

nn

ecto

r

1 - -

2 - -

3 DGND Digital ground

4 ABIS_SYNCLK_IN+ SYNCLK input

5 DGND Digital ground

6 ABIS_SYNCLK0+ SYNCLK output

7 DGND Digital ground

8 ABIS_SYNCLK1+ SYNCLK output

9 DGND Digital ground

10 ABIS_SYNCLK2+ SYNCLK output

11 DGND Digital ground

12 - -

13 - -

14 - -

15 - -

16 DGND Digital ground

17 ABIS_SYNCLK_IN- SYNCLK input

18 DGND Digital ground

19 ABIS_SYNCLK0- SYNCLK output

20 DGND Digital ground

21 ABIS_SYNCLK1- SYNCLK output

22 DGND Digital ground

23 ABIS_SYNCLK2- SYNCLK output

24 DGND Digital ground

25

Clo

ck synch

ronizatio

n sig

nal

-

-

-

DB25

The Man-Machine Interface (MMI) is a serial communication interface between the BTS and the LMT.

The signals of the MMI interface are defined in Table 25.

Local O&M Interface

Page 62: B8018 tecnical

ZXG10 B8018 (V1.00) In-Door Base Transceiver Station Technical Manual

50 Confidential and Proprietary Information of ZTE CORPORATION

T AB L E 25 - S I G N AL D E S C R I P T I O N O F T H E MMI I N T E R F AC E

Pin-outs and Signals

No

.

Sig

nal N

am

e

En

d A

En

d B

Sig

nal

Defin

ition

Co

nn

ecto

r

LMT_1 TD+

LMT_2 TD-

LMT_3 RD+ 1

Network interface

LMT_4

External network interface

RD-

LMT_5 TXD_DEBUG

LMT_6 RXD_DEBUG 2 Serial port

LMT_7

External serial port

GND

5-pin bent D connector welded to the PCB

Subracks Top-Layer Subrack

In the top shelf, one PDM, one EIB/FIB and two CMBs can be installed.

The structure of the top shelf in its full configuration is shown in Figure 21.

F I G U R E 21 - TO P S H E L F FU L L C O N F I G U R AT I O N

The PDM distributes -48 V power to the CMB, DTRU and other modules, and provides the overload protection function.

The EIB/FIB provides the base station interfaces.

Being the main control unit of the BTS, the CMB implements the following functions:

Provides all the clocks needed by BTS

Completes remote operation & maintenance of BTS

Completes local operation & maintenance of BTS

Configuration

Functions and Principles

Page 63: B8018 tecnical

Chapter 5 – Hardware Components Introduction

Confidential and Proprietary Information of ZTE CORPORATION 51

Collects equipment alarm information and provides hot active/standby function.

Carrier Subrack

In each carrier shelf, three AEMs and three DTRUs can be installed. The three AEMs are installed on the two sides of the carrier shelf.

A carrier shelf in its full configuration is shown in Figure 22.

F I G U R E 22 - M O D U L E S I N T H E C AR R I E R S H E L F

1: AEM 2: DTRU 3: AEM

The DTRU controls and processes radio channels in GSM system, sends/receives radio channel data, modulates/demodulates baseband signals on the radio carrier, and sends/receives radio carrier signals.

The AEM combines and divides air signals.

Fan Subrack

The ZXG10 B8018 (V1.00) cabinet has three fan shelves located above the three carrier shelves for heat dissipation.

The structure of a fan shelf is shown in Figure 23.

Configuration

Functions and Principles

Configuration

Page 64: B8018 tecnical

ZXG10 B8018 (V1.00) In-Door Base Transceiver Station Technical Manual

52 Confidential and Proprietary Information of ZTE CORPORATION

F I G U R E 23 - ST R U C T U R E O F F AN S H E L F

21

1: Fan shelf panel 2, 3: Fan module

Each fan shelf can hold two fan modules that can be independently plugged/unplugged to ensure that they do not affect each other during their running.

There are sockets on the back of each fan shelf and on the rear columns to connect the fan shelf with the rear columns.

On the back of each fan shelf is a fan control board to control the rotation speed and wind volume of the fans, based on the temperature measured by the temperature probe on this fan control board.

Air Filter Subrack

Located in the bottom layer of the cabinet, the air filter shelf performs the dustproof function.

The structure of the air filter shelf is shown in Figure 24.

F I G U R E 24 - AI R F I L T E R S H E L F S T R U C T U R E

2

1

1: Structural part of the air filter shelf 2: Dustproof cotton

Page 65: B8018 tecnical

Chapter 5 – Hardware Components Introduction

Confidential and Proprietary Information of ZTE CORPORATION 53

Backplane

There are two types of backplanes in ZXG10 B8018 (V1.00) cabinet.

BBCM

The backplane used by the top shelf (CMB) is the BBCM (Motherboard of CMB).

The BBCM bears the active and standby CMBs and transmits information between the active/standby CMBs and the carrier shelves/rack top/PDM.

BBTR

The backplane used by the carrier shelves is the BBTR (Motherboard of the Transceiver Module).

The BBTR can bear three DTRUs and three AEMs. It provides the following functions:

Sends the clock and downlink data from the CMB to the DTRU, and sends the uplink data from the DTRU to the CMB.

Receives the alarms output by the AEM and the FCM.

Supplies ± 12 V tower mounted amplifier power to the cabinet top.

A Type D socket is located on the top of each ZXG10 B8018 (V1.00) cabinet. In the socket, a circuit board with a DIP switch is installed, which can be used to set the cabinet ID.

Note:

For DIP switches S1 and S2, ‘0’ means ‘ON’ and ‘1’ means ‘OFF’.

Bits 1 ~ 8 of DIP switch S1 stand for bits 0 ~ 7 of the ID while Bits 1 ~ 8 bits of S2 stand for bits 8 ~ 15 of the ID.

The CMB reads ID when being powered on and initialized to decide the cabinet level (basic/extended), synchronization clock port of the SDH network, and the O&M timeslot position.

When the switches are set to ON, the ID status collected by the CMB is 0; otherwise, the status is 1.

ID is a 16-bit serial number, as shown in Figure 25.

DIP Switches and Jumpers

Page 66: B8018 tecnical

ZXG10 B8018 (V1.00) In-Door Base Transceiver Station Technical Manual

54 Confidential and Proprietary Information of ZTE CORPORATION

F I G U R E 25 - CAB I N E T -TO P D IP S W I T C H E S

The meaning of each bit is explained as follows:

BTS_TYPE

1100: B8018

1101: B8112

1110: M8202

1111: M8204

BTS_NO

No. of the cabinet of the same site

00: Basic cabinet

01: Extended cabinet 1

10: Extended cabinet 2

SLAVE1_PORT

The E1 port of the basic cabinet to connect extended cabinet 1

00: Port E of the basic cabinet

01: Port F of the basic cabinet

10: Port G of the basic cabinet

11: Port H of the basic cabinet

SLAVE2_PORT

The E1 port of the basic cabinet to connect extended cabinet 2

00: Port E of the basic cabinet

01: Port F of the basic cabinet

10: Port G of the basic cabinet

11: Port H of the basic cabinet

SATE

Whether to use the satellite Abis link or not

0: Common Abis

1: Satellite Abis

ABIS_PORT

Page 67: B8018 tecnical

Chapter 5 – Hardware Components Introduction

Confidential and Proprietary Information of ZTE CORPORATION 55

O&M port number

00: Port A

01: Port B

10: Port C

11: Port D

ABIS_TS

The O&M LAPD timeslot on the Abis interface

000: TS16

001: TS31

010: TS30

011: TS29

100: TS28

101: TS27

110: TS26

111: TS25

The number of the E1 port of the basic cabinet to connect the lower-level site cannot be the same as of SLAVE_PORT1 or SLAVE_PORT2. For example, suppose Port D of the basic cabinet connects with the lower-level site, then the values of SLAVE_PORT1 and SLAVE_PORT2 cannot be 01.

Boards, Modules and Switches Controller & Maintenance Board (CMB)

CMB is a major digital board in ZXG10 B8018 (V1.00) providing interface and central control functions. CMB works in active/standby mode, to avoid interruption and give protection to the services.

The functions of CMB are listed below:

Provides eight E1/T1 interfaces.

Overall radio clock and transmission clock synchronization can be achieved by configuring CMB for overall network synchronization at background.

Functions

Page 68: B8018 tecnical

ZXG10 B8018 (V1.00) In-Door Base Transceiver Station Technical Manual

56 Confidential and Proprietary Information of ZTE CORPORATION

Implements switching of thirty-two 2 M HW time slots with 2 bit switching array.

Provides transparent passage for external environment alarm.

Implements multi-BTS PCM link sharing.

Supports star, chain, tree, and ring networking at Abis interface.

Provides combined cabinets capacity expansion among many physical racks of one site.

Provides all kinds of clock needed in BTS; including clock signal of 13 MHz, 2.048 MHz, 60 ms, 8K_8MW, 8 MHz, 16 MHz and so on.

Detects, controls, and maintains the whole BTS system, support near-end and far-end management interface (the near-end interface is 10BaseT Ethernet network management interface).

Manages program of each board and version of FPGA configuration file in system. Support near-end and far-end version update.

Monitoring and control of each board running status includes:

Detect in-position indication

Send control command by control link

Software reset each board in system

Implement power switch of each board in system,

Implement power ON/OFF of each board in system by interruption signal

Employ digital loose coupling with micro-processor based phase locked loop. Synchronize various external reference clocks. The system is capable to filter jitter and wander noise (external reference source can be Abis line recovery clock, and can be chosen by CMU according to actual configuration).

Board power interface (-48 V, -48 V ground, protection ground, digital ground) has the inverse polarity protection function for power connection.

Implements, and reads various hardware management IDs of system, for example:

Rack number (ID_DOG)

Layer number

Slot number

Board function type

Hardware version of board

Reset button, switching push button, and compulsive power on button are available at front panel

Board provides active/standby switching

Page 69: B8018 tecnical

Chapter 5 – Hardware Components Introduction

Confidential and Proprietary Information of ZTE CORPORATION 57

Active/standby signal is multiplexed by high impedance

Provides compulsive power ON module for board/module

The functional diagram of the board is shown in Figure 26.

F I G U R E 26 – CMB F U N C T I O N AL D I AG R AM

The CMB Panel is shown in Figure 27.

F I G U R E 27 – CMB P AN E L

CMB

PWR RUN SYN CLK MST STA M/S RST FPWR

There are six LEDs on CMB panel: PWR, RUN, SYN, CLK, MST, and STA respectively. Description of CMB panel LEDs is given in Table 26.

T AB L E 26 – CMB P AN E L LED S

LED

P

ositio

n

Co

lor

Nam

e

Mean

ing

Wo

rkin

g

Mo

de

1 Green/Red

PWR Power LED

Green ON: Normal

Red ON: Alarm

OFF: Power off or other reasons

Functional Diagram

CMB Panel

Page 70: B8018 tecnical

ZXG10 B8018 (V1.00) In-Door Base Transceiver Station Technical Manual

58 Confidential and Proprietary Information of ZTE CORPORATION

LED

P

ositio

n

Co

lor

Nam

e

Mean

ing

Wo

rkin

g

Mo

de

2 Green RUN Running LED

Green flashing at 4 Hz: Boot is running

Green flash at 1 Hz: Application is running

Others: System is abnormal

3 Green/Red

SYN

Clock synchronization mode LED

Green ON: Synchronization clock of the Abis interface network

Green flashing at 1 Hz: Synchronization clock of the SDH network

Red flashing at 1 Hz: E1 frame out-of-sync alarm

Red ON: E1 line is broken or not connected

OFF: Free running

4 Green/Red CLK Clock LED

Green ON: Network synchronization is locked

Green flashing at 1 Hz: Locking the phase

Red ON: Clock fault

5 Green MST Active/Standby LED

Green ON: Active state

Green OFF: Standby state

6 Green/Red

STA Status LED

OFF: Running normally

Green flashing at 1 Hz: System initialization (Low).

Green flashing at 4 Hz: software loading

Red flashing at 1 Hz: LAPD link disconnection (High).

Red flashing at 4 Hz: HDLC link disconnection (Low).

Red ON: Other alarms (such as temperature, clock and frame number alarms)

Page 71: B8018 tecnical

Chapter 5 – Hardware Components Introduction

Confidential and Proprietary Information of ZTE CORPORATION 59

Note:

‘Low’ refers to low priority alarms and ‘High’ refers to high priority alarms.

No LAPD link disconnection alarm is defined for the standby CMB.

The HDLC link disconnection alarm of the active CMB in the basic cabinet is defined as CCComm indication (communication between active CMBs of different cabinets). The HDLC link disconnection alarm of all the standby CMBs is defined as CMComm indication (communication between active and standby CMBs).

When CMB is powered on, the PWR LED remains ON in green color. During the hardware initialization, all LEDs flash once to indicate that the LEDs are working normally. If the self-test fails, the RUN LED turns red, and the board restarts in 3 seconds.

CMB panel provides one External Test Port (ETP), two buttons (one reset button RST and one manual active/standby switchover button M/S), and one switch (FPWR).

Buttons and switch on the CMB panel are defined in Table 27.

T AB L E 27 – BU T T O N S AN D S W I T C H O N CMB P AN E L

Name Type Meaning Function

M/S Lock-free button

Active/standby switchover button

This button is invalid if the board is standby.

If the board is active and there exists a standby board working normally, press this button for active/standby switchover.

RST Lock-free button

Reset button Press this button to reset this module.

FPWR Switch Power It forcefully powers on all DTRUs.

On the CMB panel, there is only one test port, ETP. Connect the PC with BTS, ZXG10 B8018 (V1.00) using RS232 serial port and the network port for local operation and maintenance on the LMT, as shown in Figure 28.

External Interfaces

Page 72: B8018 tecnical

ZXG10 B8018 (V1.00) In-Door Base Transceiver Station Technical Manual

60 Confidential and Proprietary Information of ZTE CORPORATION

F I G U R E 28 - LO C AL OP E R AT I O N AN D M AI N T E N AN C E O F ZXG10 B8018 (V1 .00 )

MOMMI

MO

MOBTS

CMM

LMT ...

The board layout, showing DIP Switches is shown in Figure 29.

F I G U R E 29 - BO AR D L AY O U T S H O W I N G D IP S W I T C H E S

The S7 DIP switches are described in Table 28, while S10 DIP switches are described in Table 29.

T AB L E 28 – S7 D IP S W I T C H E S

Circuitry Interface Mode

Switch 1 Switch 2 Switch 3 Switch 4

Hold ON ON

100 Ω T1 OFF ON

120 Ω E1 ON OFF

75 Ω E1

Hold

OFF OFF

To select between 2 MHz clock and network clock. Default is 1 (Network clock)

DIP Switches

Page 73: B8018 tecnical

Chapter 5 – Hardware Components Introduction

Confidential and Proprietary Information of ZTE CORPORATION 61

T AB L E 29 – S10 D IP S W I T C H E S

Circuitry Interface Mode

Switch 1 Switch 2 Switch 3 Switch 4

ALM_IN11 input

ON ON OFF OFF

2 MHz clock input

OFF OFF ON ON

No external input

OFF OFF OFF OFF

Hold ON ON ON ON

E1/T1 Interface Board (EIB)

The EIB provides the Abis interface connecting to the BSC.

Main function of EIU (E1/T1 Interface Unit) are as follows:

Provide line impedance matching of 8 E1/T1

Signal isolation at IC side and line side

Line protection at E1/T1 line interface

Bypass function of E1/T1 line.

Provides type information of interface board to CMU

Functional diagram of EIB is shown in Figure 30.

F I G U R E 30 – E IB FU N C T I O N AL D I AG R AM

匹配电路

变压器

保护器件

跨接继电器

EIB

8 E1/T1

Functions

Functional Diagram

Page 74: B8018 tecnical

ZXG10 B8018 (V1.00) In-Door Base Transceiver Station Technical Manual

62 Confidential and Proprietary Information of ZTE CORPORATION

EIB Panel is shown in Figure 31.

F I G U R E 31 - E IB P AN E L

EIB

The board layout, showing DIP Switches is shown in Figure 32.

F I G U R E 32 - BO AR D L AY O U T S H O W I N G D IP S W I T C H E S

S2

S4

S6

S5

There are four DIP switches on EIB board to select line impedance: S2, S4, S5, and S6. These are described in Table 30.

T AB L E 30 - D IP S W I T C H E S M E AN I N G S

- S2 S4 S5 S6

PIN 1, 2 E1C E1A E1G E1E

PIN 3, 4 E1D E1B E1H E1F

Table 31 shows the working mode of DIP switches.

T AB L E 31 - D IP S W I T C H E S W O R K I N G M O D E S

Line interface mode 1 2 3 4

100 Ω T1 OFF ON OFF ON

120 Ω E1 OFF OFF OFF OFF

EIB Panel

DIP Switches

Page 75: B8018 tecnical

Chapter 5 – Hardware Components Introduction

Confidential and Proprietary Information of ZTE CORPORATION 63

Line interface mode 1 2 3 4

75 Ω E1 ON OFF ON OFF

Power Distribution Module (PDM)

The ZXG10 B8018 (V1.00) adopts the fully distributed power supply. It distributes -48 V primary power to CMB and DTRU. The secondary power supply for each module is generated by the power supply module, present on each module.

PDM distributes the -48 V power to CMBs, DTRUs and FCMs, and provides overload protection via circuit breakers. In addition to a circuit breaker for each module, a main switch circuit breaker is placed at the -48 V input end on the top of the BTS cabinet.

Functional diagram of PDM is shown in Figure 33.

F I G U R E 33 - PDM FU N C T I O N AL D I AG R AM

PWR

-48VGND

CMM1

CMM2

TRM/ETRM1

TRM/ETRM12

Circuit breaker Filter

2 CMMs

12 TRMs/ETRMs

PWRGND

-48V

.

.

.

The PDM panel is shown in Figure 34.

Functions

Functional Diagram

PDM Panel

Page 76: B8018 tecnical

ZXG10 B8018 (V1.00) In-Door Base Transceiver Station Technical Manual

64 Confidential and Proprietary Information of ZTE CORPORATION

F I G U R E 34 - PDM P AN E L

There are 12 breakers on the PDM panel controlling the power supply of two CMBs, one EIB, and nine DTRUs.

Transceiver Module for EDGE (DTRU)

The DTRU controls and processes radio channels in the GSM system, sends/receives radio channel data, modulates/demodulates baseband signals on the radio carrier, sends/receives radio carrier signals, and collects alarms of the fans and AEMs.

To adapt to different GSM systems and different output power requirements, different DTRUs have been designed for ZXG10 B8018 (V1.00). Table 32 shows the types of DTRUs.

T AB L E 32 - TY P E S O F DTRUS

Working Band Module Name

GSM900 DTRUG

GSM850 DTRUM

GSM1800 DTRUD

GSM1900 DTRUP

Main functions of DTRU are as follows:

Processes 2 carriers at maximum in downlink:

Complete rate adaptation

Functions

Page 77: B8018 tecnical

Chapter 5 – Hardware Components Introduction

Confidential and Proprietary Information of ZTE CORPORATION 65

Channel coding and interleaving

Encryption

Generating TDMA burst pulse

Complement GMSK/8PSK modulation

Digital up-conversion of the two carriers

Processes 2 carriers at maximum in uplink:

Implement uplink digital down conversion

Diversity combining of receiver

Digital demodulation (GMSK and 8PSK demodulation, equalization)

Decrypting

De-interleaving

Rate adaptation

Implement processing of uplink and downlink RF signal.

Receive the system clock from CMB and generate the clock needed by this module.

Implement and read various hardware management IDs of system: rack number, slot number, board function type, and hardware version of board, and so on.

Implement communication of service data and operation and maintenance signaling through one 8 Mbps HW.

Receive switching signal of CMB to complete power ON/OFF of module.

Support online update and load of software version, support version update of programmable device.

Detect working state of module, collect alarm signal in real time and report it to CMB.

Support RF frequency hopping, DPCT, downlink transmission diversity, and four diversities reception in uplink.

Support close-loop power control.

Provide debugging serial interface and network interface.

Board power interface (-48 V, -48 V ground, protection ground, digital ground) has the inverse polarity protection function for power connection.

Delayed start function and intelligent power ON/OFF function.

DTRU Panel is shown in Figure 35. DTRU Panel

Page 78: B8018 tecnical

ZXG10 B8018 (V1.00) In-Door Base Transceiver Station Technical Manual

66 Confidential and Proprietary Information of ZTE CORPORATION

F I G U R E 35 – DTRU P AN E L

DTRUG

TX1

TXcomRXM1

RXM2

RXD1

RXD2

TX2

PWR

RUN

MOD

ACT1

ACT2

STA

RST

ETP

Panel indicators are given in Table 33.

T AB L E 33 – DTRU P AN E L LED S

Identifier Full Name Meaning

PWR Power Power LED

RUN Run Running LED

MOD Model BCCH mode LED

ACT1 Active Channel activation LED1

ACT2 Active Channel activation LED2

STA State Status LED

RST Reset Reset button

DTRU External Interfaces are described in Table 34.

T AB L E 34 - DTRU E X T E R N AL I N T E R F AC E S

Identifier Meaning

RXM1 Receiver 1

Panel Indicators

External Interfaces

Page 79: B8018 tecnical

Chapter 5 – Hardware Components Introduction

Confidential and Proprietary Information of ZTE CORPORATION 67

Identifier Meaning

RXD1 Receiver 1 (for diversity)

RXM2 Receiver 2

RXD2 Receiver 2 (for diversity)

TX1 Transmitter 1

TX2 Transmitter 2

TXcom Transmitter Combiner

ETP Extend Test Port

AEM (Antenna Equipment Module)

The location of AEM in the system is shown in Figure 36.

F I G U R E 36 - AEM LO C AT I O N I N T H E S Y S T E M

TRMs or ETRMs

TX

RXAEM

The AEM provides the following functions:

Combines the transmit signals of multiple carriers.

Provides bidirectional signal channels from the BTS to the antenna for the transmitting band and from the antenna to the BTS for the receiving band.

Gives an alarm when the VSWR of the antenna port deteriorates.

Suppresses the interference out of the working band and spurious emission.

Flexibly configures carriers.

Implements diversity receiving.

The AEM consists of CDU and CEU. The CDU is the major component while CEU cooperates with CDU to configure a specific number of carriers of BTS.

In addition, each AEM contains one power interface board (DAEM), which supplies power to the internal and external amplifiers of AEU and reports alarm signals to TPU.

Classification

Page 80: B8018 tecnical

ZXG10 B8018 (V1.00) In-Door Base Transceiver Station Technical Manual

68 Confidential and Proprietary Information of ZTE CORPORATION

To adapt to different working bands such as GSM900, EGSM900, GSM850, GSM1800 and GSM1900, different AEMs have been designed for ZXG10 B8018 (V1.00).

Table 35 shows the types of AEMs according to CDU types, while Table 26 shows the types of AEMs according to working bands.

T AB L E 35 - TY P E S O F AEM S ( AC C O R D I N G T O CDU TY P E )

Unit Name

Module Name Working Frequency

CDUG Rx: 890 MHz - 915 MHz

Tx: 935 MHz - 960 MHz

BCDUG Rx: 880 MHz - 905 MHz

Tx: 925 MHz - 950 MHz

CCDUG Rx: 885 MHz - 910 MHz

Tx: 930 MHz - 955 MHz

RCDUG_8M Rx: 882 MHz - 890 MHz

Tx: 927 MHz - 935M Hz

RCDUG_10M Rx: 880 MHz - 890 MHz

Tx: 925 MHz - 935 MHz

CDUD Rx: 1710 MHz - 1785 MHz

Tx: 1805 MHz - 1880 MHz

CDUC Rx: 824 MHz - 849 MHz

Tx: 869 MHz- 894 MHz

CDU

CDUP Rx: 1850 MHz - 1910 MHz

Tx: 1930 MHz - 1990 MHz

CEUG Rx: 880 MHz - 915 MHz

Tx: 925 MHz - 960 MHz

CEUD Rx: 1710 MHz - 1785 MHz

Tx: 1805 MHz - 1880 MHz

CEUC Rx: 824 MHz - 849 MHz

Tx: 869 MHz - 894 MHz

CEU

CEUP Rx: 1850 MHz - 1910 MHz

Tx: 1930 MHz - 1990 MHz

T AB L E 36 - TY P E S O F AEM S ( AC C O R D I N G T O W O R K I N G B AN D )

Working Band

Module Name

Description

CDUG

CEUG GSM900

BCDUG

These three modules can be flexibly combined in the GSM900 system to implement various configurations of BTS carriers.

EGSM900 BRDUG The uplink/downlink frequency of BCDUG is 10 GHz; lower than that of CDUG. The

Page 81: B8018 tecnical

Chapter 5 – Hardware Components Introduction

Confidential and Proprietary Information of ZTE CORPORATION 69

Working Band

Module Name

Description

CEUG

CCDUG

uplink/downlink frequency of the BRDUG is 10 GHz lower. The CEU directly uses the CEUG of the GSM900 system.

In the corresponding working band of EGSM900 system, these three modules can be combined flexibly to implement various configurations of BTS carriers.

CRDUG

CEUG

RCDUG_8M

The uplink/downlink frequency of CCDUG is 5 GHz lower than that of CDUG in terms of uplink/downlink frequency while the uplink/downlink frequency of CRDUG is 5 GHz lower than that of the RDUG. The CEU directly uses the CEUG of the GSM900 system.

In the corresponding working band of EGSM900 system, these three modules can be combined flexibly to implement various configurations of BTS carriers.

CEUG

RCDUG_10M

These two modules can be flexibly combined in the corresponding working band of EGSM900 system to implement various configurations of BTS carriers.

CEUG

CDUC

These two modules can be flexibly combined in the corresponding working band of EGSM900 system to implement various configurations of BTS carriers.

RDUC

CEUC GSM850

CDUD

These modules can be flexibly combined in GSM850 system to implement various configurations of BTS carriers.

RDUD

CEUD GSM1800

CDUP

These modules can be flexibly combined in GSM1800 system to implement various configurations of BTS carriers.

RDUP

CEUP GSM1900

CDUP

These modules can be flexibly combined in GSM1900 system to implement various configurations of BTS carriers.

Comparison between different CEUs and CENs is shown in Table 37.

T AB L E 37 - C O M P AR I S O N B E T W E E N D I F F E R E N T CEU S AN D CEN S

Name No. of Combiners & Splitters Width Slot No.

CEU Two 2-to-1 Combiner

Two 1-to-2 Splitter

90 mm 1st, 6th

Page 82: B8018 tecnical

ZXG10 B8018 (V1.00) In-Door Base Transceiver Station Technical Manual

70 Confidential and Proprietary Information of ZTE CORPORATION

Name No. of Combiners & Splitters Width Slot No.

CEU/2 Two 2-to-1 Combiner

Two 1-to-2 Splitter

80 mm 5th

CENU Two 3-to-1 Combiner

Two 1-to-4 Splitter

90 mm 1st, 6th

CENU/2 Two 3-to-1 Combiner

Two 1-to-2 Splitter

90 mm 5th

CENU/3 Two 3-to-1 Combiner

Two 1-to-4 Splitter

80 mm 5th

CENU/4 Two 3-to-1 Combiner

Two 1-to-2 Splitter

80 mm 5th

CDU (Combiner Distribution Unit)

CDUs are of different types with respect to different working bands:

CDUG

BCDUG

CCDUG

RCDUG_8M

RCDUG_10M

CDUC

CDUD

CDUP

The CDU is composed of four parts:

Broadband combiner

Transceiving duplexer

VSWR detection circuit

LNA (including a splitter)

The combiner combines the output signals from multiple transmitters into one output port for output.

Function

Page 83: B8018 tecnical

Chapter 5 – Hardware Components Introduction

Confidential and Proprietary Information of ZTE CORPORATION 71

CDU functional blocks are shown in Figure 37.

F I G U R E 37 - FU N C T I O N AL B L O C K S O F T H E CDU

The CDU supports one 2-in-1 combiner, a 1-to-4 low-noise amplifier. It has two low noise amplifiers with extended receiving output and one built-in duplexer.

All the CDUs have the same panel. The following example describes the CDUG panel.

The panel of the CDUG is shown in Figure 38.

Functional Blocks

CDU Panel

Page 84: B8018 tecnical

ZXG10 B8018 (V1.00) In-Door Base Transceiver Station Technical Manual

72 Confidential and Proprietary Information of ZTE CORPORATION

F I G U R E 38 - CDUG P AN E L S T R U C T U R E

The following appear on the CDUG panel:

5 LEDs

1 Extended TX port (ETX)

1 Radio test port (RTE)

2 Combiner input ports (TX1 - TX2)

4 Low-noise amplifier output ports (RX1 - RX4)

2 Low-noise amplifier extended output ports (ERX1 - ERX2)

1 Antenna feeder port (ANT)

CDUG external interfaces are given in Table 38.

T AB L E 38 – CDUG E X T E R N AL I N T E R F AC E S

Identifier Full Name Meaning

ETX Extended TX Extended TX port

RTE Radio Test Equipment

Radio test port

TX1 Transmitter 1 Combiner input 1 (PA output signal)

TX2 Transmitter 2 Combiner input 2 (PA output signal)

External Interfaces

Page 85: B8018 tecnical

Chapter 5 – Hardware Components Introduction

Confidential and Proprietary Information of ZTE CORPORATION 73

Identifier Full Name Meaning

RX1 Receiver 1 Low noise amplifier output port 1

RX2 Receiver 2 Low noise amplifier output port 2

RX3 Receiver 3 Low noise amplifier output port 3

RX4 Receiver 4 Low noise amplifier output port 4

ERX1 Extend Receiver 1 Low noise amplifier extended output port 1

ERX2 Extend Receiver 2 Low noise amplifier extended output port 2

ANT Antenna Antenna feeder port

The LEDs on the panels of different CDUs are same.

The five LEDs on the CDU panel are EPO, SWR1, SWR2, PWR and LNA respectively. These are described in Table 39.

T AB L E 39 - CDU P AN E L LED S

LED Position

Color Name Meaning Working Mode

1 Green FPO Forward power output LED

ON: Normal

OFF: Abnormal

2 Red SWR1 VSWR level-1 alarm LED

ON: There is an alarm

OFF: There is no alarm

3 Red SWR2 VSWR level-2 alarm LED

ON: There is an alarm

OFF: There is no alarm

4 Green PWR LNA power supply LED

ON: Normal

OFF: Abnormal

5 Red LNA LNA alarm LED

ON: There is an alarm

OFF: There is no alarm

“E” Combiner Distribution Unit (ECDU)

ECDU provides the following functions:

Providing bi-directional channel from BTS to the antenna for signals of the transmitting frequency band and from the antenna to BTS for signals of the receiving frequency band.

Reporting alarms when SWR of the antenna port deteriorates.

Suppressing interference and spurious emission beyond the working frequency band.

Panel Indicators

Functions

Page 86: B8018 tecnical

ZXG10 B8018 (V1.00) In-Door Base Transceiver Station Technical Manual

74 Confidential and Proprietary Information of ZTE CORPORATION

ECDU Functional blocks are shown in Figure 39.

F I G U R E 39 – ECDU FU N C T I O N AL B L O C K S

ECDU consists of a transceiving duplexer, VSWR detecting circuit, two LNAs (each LNA includes one 1-to-2 splitter) and a receiver filter. It can meet diversity reception requirements.

ECDU have three types of panels:

ECDUG (GSM900/EGSM900)

ECDUD (GSM1800)

ECDUC (GSM850)

All the ECDUs have same panel. Figure 40 shows the ECDU panel.

Functional Blocks

ECDU Panel

Page 87: B8018 tecnical

Chapter 5 – Hardware Components Introduction

Confidential and Proprietary Information of ZTE CORPORATION 75

F I G U R E 40 - ECDU P AN E L

ECDUG External Interfaces are described in Table 40

T AB L E 40 – ECUG E X T E R N AL I N T E R F AC E S

Identification Symbol

Full Name Meaning

RTE Radio Test Equipment Radio test port

RX1 Receiver 1 Low-noise amplifier output port 1

RX2 Receiver 2 Low-noise amplifier output port 2

RXD1 Receiver for Diversity1

Low-noise amplifier output port 1 (diversity)

RXD2 Receiver for Diversity2

Low-noise amplifier output port 2 (diversity)

ANT Antenna Antenna feeder port

ANTD Antenna for Diversity Antenna feeder port (diversity)

External Interfaces

Page 88: B8018 tecnical

ZXG10 B8018 (V1.00) In-Door Base Transceiver Station Technical Manual

76 Confidential and Proprietary Information of ZTE CORPORATION

Table 41 gives a description of LEDs on ECDU panel.

T AB L E 41 - ECDU P AN E L LED S

LED Position

Color Name Meaning Working Mode

1 Green FPO Forward power output LED

ON: Normal

OFF: Abnormal

2 Red SWR1 VSWR level-1 alarm LED

ON: There is an alarm

OFF: There is no alarm

3 Red SWR2 VSWR level-2 alarm LED

ON: There is an alarm

OFF: There is no alarm

4 Green PWR LNA power supply LED

ON: Normal

OFF: Abnormal

5 Red LNA1 Channel 1 LNA alarm

ON: There is an alarm

OFF: There is no alarm

6 Red LNA2 Channel 2 LNA alarm

ON: There is an alarm

OFF: There is no alarm

Combiner Extension Unit (CEU)

By different working bands, CEU is of different types:

CEUG

CEUC

CEUD

CEUP

CEU provides various site configurations with the combination of CDU.

The CEU consists of two 2-in-1 combiners and two 1-to-2 splitters, as shown in Figure 41.

Panel Indicators

Function

Functional Blocks

Page 89: B8018 tecnical

Chapter 5 – Hardware Components Introduction

Confidential and Proprietary Information of ZTE CORPORATION 77

F I G U R E 41 - CEU FU N C T I O N AL B L O C K S

The CEU is combined with CDU to form a 4-in-1 combiner distribution unit.

CEU type 2 (CEU/2) has the same functions as CEU. However, its width is 10 mm less than CEU and it uses different slot in the cabinet.

All the CEUs have the same panel.

The CEU panel is shown in Figure 42.

CEU and CEU/2 Panels

Page 90: B8018 tecnical

ZXG10 B8018 (V1.00) In-Door Base Transceiver Station Technical Manual

78 Confidential and Proprietary Information of ZTE CORPORATION

F I G U R E 42 - ST R U C T U R E O F CEU P AN E L

TX4

ERX2 OTX2

OTX1

TX3

CEUG

The following appear on the CEU panel:

2 combiner TX output ports OTX1 and OTX2

4 combiner input ports TX1 - TX4 (PA output signal)

4 splitter output ports RX1 - RX4

2 splitter input ports ERX1 - ERX2 (LNA extended outputs)

All the CEU/2 boards have the same panel.

The CEUG/2 panel is shown in Figure 43.

Page 91: B8018 tecnical

Chapter 5 – Hardware Components Introduction

Confidential and Proprietary Information of ZTE CORPORATION 79

F I G U R E 43 – CEUG/2 P AN E L

CEUG/2

ERX1

RX1

TX1

OTX1

RX2

ERX2

OTX2

TX3

RX3

TX2

RX4

TX4

The CEU external interfaces are described in Table 42.

T AB L E 42 – CEU E X T E R N AL I N T E R F AC E S

Identifier Meaning Description

OTX1 Output TX 1 Combiner TX output port 1

OTX2 Output TX 2 Combiner TX output port 2

TX1 Transmitter 1 Combiner input 1 (PA output signal)

TX2 Transmitter 2 Combiner input 2 (PA output signal)

TX3 Transmitter 3 Combiner input 3 (PA output signal)

TX4 Transmitter 4 Combiner input 4 (PA output signal)

RX1 Receiver 1 Splitter output port 1

RX2 Receiver 2 Splitter output port 2

RX3 Receiver 3 Splitter output port 3

RX4 Receiver 4 Splitter output port 4

ERX1 Extend Receiver 1

Splitter input port 1 (low noise amplifier extended output)

External Interfaces

Page 92: B8018 tecnical

ZXG10 B8018 (V1.00) In-Door Base Transceiver Station Technical Manual

80 Confidential and Proprietary Information of ZTE CORPORATION

Identifier Meaning Description

ERX2 Extend Receiver 2

Splitter input port 2 (low noise amplifier extended output)

Combiner Extension Net Unit (CENU)

CENU performs the same functions as CEU, but supports different configurations.

CENU is of two types:

CENU (Supports configuration of S 9/9/9 ~ S 12/12/12)

CENU/2 (Supports configuration of S 5/5/5 ~ S 6/6/6)

CENU functional blocks are shown in Figure 44.

F I G U R E 44 – CENU FU N C T I O N AL B L O C K S

CENU & CENU/2

Functional Blocks

Page 93: B8018 tecnical

Chapter 5 – Hardware Components Introduction

Confidential and Proprietary Information of ZTE CORPORATION 81

CENU/2 functional blocks are shown in Figure 45.

F I G U R E 45 – CENU/2 FU N C T I O N AL B L O C K S

Page 94: B8018 tecnical

ZXG10 B8018 (V1.00) In-Door Base Transceiver Station Technical Manual

82 Confidential and Proprietary Information of ZTE CORPORATION

All the CENs have same panels.

CENUG panel is shown in Figure 46.

F I G U R E 46 - CENUG P AN E L

TX6

TX5

TX4

OTX2

RX8

RX7

ERX2

RX6

RX5

TX3

TX2RX4

RX3

TX1ERX1

RX2

OTX1RX1

CENUG

CENU, CENU/2, CENU/3 &

CENU/4 Panels

Page 95: B8018 tecnical

Chapter 5 – Hardware Components Introduction

Confidential and Proprietary Information of ZTE CORPORATION 83

All the CENU/2 boards have same panels.

CENUG/2 panel is shown in Figure 47.

F I G U R E 47 - CENUG/2 P AN E L

CENUG/2

OTX1

TX1

TX2

TX3

OTX2

TX4

TX6

TX5RX4

RX3

ERX2

RX2

RX1

ERX1

Page 96: B8018 tecnical

ZXG10 B8018 (V1.00) In-Door Base Transceiver Station Technical Manual

84 Confidential and Proprietary Information of ZTE CORPORATION

All the CENU/3 boards have same panels.

CENUG/3 panel is shown in Figure 48.

F I G U R E 48 – CENUG/3 P AN E L

CENUG/3

RX1

RX2

ERX1

RX3

RX4

RX5

RX6

ERX2

RX7

RX8

OTX1

TX1

TX2

TX3

OTX2

TX4

TX5

TX6

Page 97: B8018 tecnical

Chapter 5 – Hardware Components Introduction

Confidential and Proprietary Information of ZTE CORPORATION 85

All the CENU/4 boards have same panels.

CENUG/4 panel is shown in Figure 49.

F I G U R E 49 – CENUG/4 P AN E L

CENUG/4

ERX1

RX1

RX2

ERX2

RX3

RX4 TX5

TX6

TX4

OTX2

TX3

TX2

TX1

OTX1

Page 98: B8018 tecnical

ZXG10 B8018 (V1.00) In-Door Base Transceiver Station Technical Manual

86 Confidential and Proprietary Information of ZTE CORPORATION

This page is intentionally blank.

Page 99: B8018 tecnical

Confidential and Proprietary Information of ZTE CORPORATION 87

C h a p t e r 6

Networking Modes and Configuration

Networking Modes

Figure 50 shows star networking of ZXG10 B8018 (V1.00). Each line denotes a bi-directional E1 connection. The DIP switch settings of BTS should be according to the background configurations.

F I G U R E 50 – S T AR N E T W O R K I N G S C H E M AT I C D I AG R AM

BSC

SITE0

SITE1

SITEn

.

.

.

In star networking, each site contains n E1 PCM links directly connected with BSC. BTS uses terminal equipment on each site to terminate E1 links. Since signal transmission is through fewer intermediate links along the path, the reliability of transmission is higher. This networking mode is deployed in densely populated areas.

Figure 51 shows the chain networking of ZXG10 B8018 (V1.00). Each line denotes a bi-directional E1 connection. The DIP switch

Star Networking

Chain Networking

Page 100: B8018 tecnical

ZXG10 B8018 (V1.00) In-Door Base Transceiver Station Technical Manual

88 Confidential and Proprietary Information of ZTE CORPORATION

settings of BTS should be according to the background configurations.

F I G U R E 51 – C H AI N N E T W O R K I N G S C H E M AT I C D I AG R AM

SITE 0BSC SITE 1 SITE 2

Chain networking is applicable to one-site multi-BTS situation. Since signals go through more links, the line reliability is relatively poor than star networking. This networking mode is applicable to stripe-like areas with a small population, which saves a large number of transmission devices. To prevent the clock performance drop, it is recommended not to connect more than four BTSs in cascaded form in chain networking mode.

Figure 52 shows the tree-networking mode of ZXG10 B8018 (V1.00). Each line denotes a bi-directional E1 connection. The DIP switch settings of BTS should be according to the background configurations.

F I G U R E 52 – TR E E -N E T W O R K I N G S C H E M AT I C D I AG R AM

.

.

.

BSC

SITE 0

SITE 1

SITE 2

SITE n

In this mode, signals pass through many nodes and the line reliability is relatively low, which makes it complicated. The fault from upper-level site can affect the proper running of the lower-level site. In tree-networking, BTS connects with BSC through central node, which further distributes itself into three nodes. The tree-networking mode is deployed in large areas with less population.

In actual networking projects, due to decentralized sites, the transmission equipment is used for intermediate connection between BSC and BTS. A common transmission mode includes microwave, optical fibers, HDSL cables, and coaxial cables. Satellite links can be used for special transmission modes.

Tree Networking

Page 101: B8018 tecnical

Chapter 6 – Networking Modes and Configuration

Confidential and Proprietary Information of ZTE CORPORATION 89

Figure 53 shows the ring-networking mode of ZXG10 B8018 (V1.00). Each line denotes a bi-directional E1 connection. The DIP switch settings of BTS should be according to the background configurations.

F I G U R E 53 - R I N G -N E T W O R K I N G S C H E M AT I C D I AG R AM

SITE 1SITE 0

SITE 2 SITE 3

BSC

In this mode, all the nodes are connected in a closed loop. It can span larger distances than other types of networks. The reliability is higher; as it stays connect with BSC through the other end, if the link is broken from one place. It can be deployed in suburb and rural areas.

Configuration Configuration Principles

Select the different modules according to the different frequency module. These modules are given in Table 43.

T AB L E 43 – MO D U L E S F O R D I F F E R E N T FR E Q U E N C I E S

Frequency Bands DTRU CDU ECDU CEU CENU

900 MHz DTRUG CDUG ECDUG CEUG CENUG

1800 MHz DTRUD CDUD ECDUD CEUD CEND

1900 MHz DTRUP CDUP ECDUP CEUP CENP

850 MHz DTRUM CDUC ECDUC CEUC CENC

Ring Networking

Module Selection

Page 102: B8018 tecnical

ZXG10 B8018 (V1.00) In-Door Base Transceiver Station Technical Manual

90 Confidential and Proprietary Information of ZTE CORPORATION

CEU/2, CENU/3 and CENU/4 must be placed at the location marked in Figure 54.

F I G U R E 54 – LO C AT I O N O F CEU/2 , CENU/3 AN D CENU/4

AEM

AEM

DTRU

DTRU

DTRU

AEM

AEM

DTRU

DTRU

AEM

AEM

AEM

DTRU

DTRU

DTRU

AEM

PDMEIB

CMBCMB

FCM

FCM

FCM

AEM

DTRU

Configuration Examples of Various Site Types

Single Carrier per Sector

Configuration of ZXG10 B8018 (V1.00) with two ECDUs requires only one DTRU. Figure 55 shows the configuration and Figure 56 shows logical connections.

Module Placement

Using ECDUs

Page 103: B8018 tecnical

Chapter 6 – Networking Modes and Configuration

Confidential and Proprietary Information of ZTE CORPORATION 91

F I G U R E 55 – C O N F I G U R AT I O N W I T H TW O ECDU S

F I G U R E 56 - LO G I C AL C O N N E C T I O N S O F CO N F I G U R AT I O N W I T H TW O ECDU S

Configuration of ZXG10 B8018 (V1.00) with two CDUs requires only one DTRU. Tower Mounted Amplifier (TMA) is placed between CDU and antenna to amplify the uplink power. Figure 57 shows the configuration and Figure 58 shows logical connections.

Using CDUs and TMA

Page 104: B8018 tecnical

ZXG10 B8018 (V1.00) In-Door Base Transceiver Station Technical Manual

92 Confidential and Proprietary Information of ZTE CORPORATION

F I G U R E 57 - CO N F I G U R AT I O N W I T H TW O CDU S AN D TMAS

F I G U R E 58 - LO G I C AL C O N N E C T I O N S O F CO N F I G U R AT I O N W I T H T W O CDU S AN D TM AS

Two Carriers per Sector (with DPCT)

Four diversities configuration of ZXG10 B8018 (V1.00) with two ECDUs requires two DTRUs. Figure 59 shows the configuration.

Using ECDUs (with DPCT)

Page 105: B8018 tecnical

Chapter 6 – Networking Modes and Configuration

Confidential and Proprietary Information of ZTE CORPORATION 93

F I G U R E 59 – S2 /2 /2 S I T E CO N F I G U R AT I O N W I T H DPCT

Two Carriers per Sector (Through Combiner)

This type of configuration requires two CDUs and a DTRU. Figure 60 shows the configuration and Figure 61 shows logical connections.

F I G U R E 60 – TW O C AR R I E R S P E R S E C T O R AN T E N N A FE E D E R C O N F I G U R AT I O N (TH R O U G H C O M B I N E R )

Page 106: B8018 tecnical

ZXG10 B8018 (V1.00) In-Door Base Transceiver Station Technical Manual

94 Confidential and Proprietary Information of ZTE CORPORATION

F I G U R E 61 – LO G I C AL C O N N E C T I O N S O F TW O C AR R I E R S P E R S E C T O R AN T E N N A FE E D E R C O N F I G U R AT I O N (TH R O U G H C O M B I N E R )

Four Carriers per Sector

Since one DTRU can support two carriers, thus this type of configuration requires two DTRUs with two CDUs. Figure 62 shows the configuration and Figure 63 shows logical connections.

F I G U R E 62 - FO U R C AR R I E R S P E R S E C T O R AN T E N N A FE E D E R C O N F I G U R AT I O N

Page 107: B8018 tecnical

Chapter 6 – Networking Modes and Configuration

Confidential and Proprietary Information of ZTE CORPORATION 95

F I G U R E 63 - LO G I C AL C O N N E C T I O N S O F FO U R C AR R I E R S P E R S E C T O R AN T E N N A FE E D E R C O N F I G U R AT I O N

Six Carriers per Sector

Since one DTRU support only two carriers, thus this type of configuration requires three DTRUs, two CDUs and one CEU. Figure 64 shows the configuration and Figure 65 shows logical connections.

F I G U R E 64 - S I X C AR R I E R S P E R S E C T O R AN T E N N A FE E D E R C O N F I G U R AT I O N (U S I N G CEU)

Using CEU

Page 108: B8018 tecnical

ZXG10 B8018 (V1.00) In-Door Base Transceiver Station Technical Manual

96 Confidential and Proprietary Information of ZTE CORPORATION

F I G U R E 65 – LO G I C AL C O N N E C T I O N S O F S I X C AR R I E R S P E R S E C T O R AN T E N N A FE E D E R C O N F I G U R AT I O N (U S I N G CEU)

Since one DTRU support only two carriers, thus this type of configuration requires three DTRUs, two CDUs and one CENU/2. CENU/2 is used to balance uplink and downlink signal powers. Figure 66 shows the configuration and Figure 67 shows logical connections.

F I G U R E 66 – S I X C AR R I E R S P E R S E C T O R AN T E N N A FE E D E R C O N F I G U R AT I O N (U S I N G CENU/2)

Using CENU/2

Page 109: B8018 tecnical

Chapter 6 – Networking Modes and Configuration

Confidential and Proprietary Information of ZTE CORPORATION 97

F I G U R E 67 – LO G I C AL C O N N E C T I O N S O F S I X C AR R I E R S P E R S E C T O R AN T E N N A FE E D E R C O N F I G U R AT I O N (U S I N G CENU/2)

Dual-Band Configuration

This is used for configuring dual-band, for example, GSM900 and GSM1800 bands in one cabinet. Figure 68 shows the configuration.

Using Four-port Antenna

Feeder

Page 110: B8018 tecnical

ZXG10 B8018 (V1.00) In-Door Base Transceiver Station Technical Manual

98 Confidential and Proprietary Information of ZTE CORPORATION

F I G U R E 68 – D U AL B AN D C O N F I G U R AT I O N U S I N G FO U R-P O R T AN T E N N A

The four-port antenna feeder connections are shown in Figure 69.

F I G U R E 69 - FO U R -P O R T AN T E N N A FE E D E R C O N N E C T I O N S

Page 111: B8018 tecnical

Chapter 6 – Networking Modes and Configuration

Confidential and Proprietary Information of ZTE CORPORATION 99

This is used for configuring dual-band, for example, GSM900 and GSM1800 bands in one cabinet. Figure 70 shows the configuration.

F I G U R E 70 - DU AL B AN D C O N F I G U R AT I O N U S I N G TW O -PO R T AN T E N N A

In two-port configuration, a combiner is used to combine dual band signals. The two-port antenna feeder connections are shown in Figure 71.

Using Two-port Antenna

Feeder

Page 112: B8018 tecnical

ZXG10 B8018 (V1.00) In-Door Base Transceiver Station Technical Manual

100 Confidential and Proprietary Information of ZTE CORPORATION

F I G U R E 71 – TW O -P O R T AN T E N N A FE E D E R C O N N E C T I O N S

S 8/8/8 Configuration Example

Three-sector fully configured S 8/8/8 configuration of ZXG10 B8018 (V1.00) requires four DTRUs and three AEMs for every sector. The cabinet configuration is shown in Figure 72.

Page 113: B8018 tecnical

Chapter 6 – Networking Modes and Configuration

Confidential and Proprietary Information of ZTE CORPORATION 101

F I G U R E 72 – S 8 /8 /8 C O N F I G U R AT I O N C A B I N E T S T R U C T U R E

Figure 73 shows the configuration for every sector and Figure 74 shows the logical connections.

Sector Configuration

Page 114: B8018 tecnical

ZXG10 B8018 (V1.00) In-Door Base Transceiver Station Technical Manual

102 Confidential and Proprietary Information of ZTE CORPORATION

F I G U R E 73 – S 8 /8 /8 C O N F I G U R AT I O N

Page 115: B8018 tecnical

Chapter 6 – Networking Modes and Configuration

Confidential and Proprietary Information of ZTE CORPORATION 103

F I G U R E 74 – S 8 /8 /8 C O N F I G U R AT I O N LO G I C AL C O N N E C T I O N S

Page 116: B8018 tecnical

ZXG10 B8018 (V1.00) In-Door Base Transceiver Station Technical Manual

104 Confidential and Proprietary Information of ZTE CORPORATION

This page is intentionally blank.

Page 117: B8018 tecnical

Confidential and Proprietary Information of ZTE CORPORATION 105

A p p e n d i x A

Abbreviation

Abbreviations Full name

A

Abis Abis

AEM Antenna Equipment Module

ARFCN Absolute Radio Frequency Channel Number

B

BCDU “B”Combiner Distribution Unit

BRDU “B”Receiver Distribute Unit

BSC Base Station Controller

BSS Base Station Subsystem

BTM Backboard Transmission Module

BTS Base Transceiver Station

C

CCDU “C”Combiner Distribution Unit

CDU Combiner Distribution Unit

CEU Combiner Extension Unit

CHP Channel Processor

CIP Carrier Interface Part

CLK CLocK

CMM Controller & Maintenance Module

D

DCDU “D”Combiner Distribution Unit

DDT Delay Diversity Transmission

DPCT Dual Power Combining Transmission

DTM Dynamic Synchronous Transfer Mode

DTRU Dual Tranciever Unit

DTX Discontinuous Transmission

Page 118: B8018 tecnical

ZXG10 B8018 (V1.00) In-Door Base Transceiver Station Technical Manual

106 Confidential and Proprietary Information of ZTE CORPORATION

Abbreviations Full name

E

E1 E1

EAM External Alarm Module

ECDU “E”Combiner Distribution Unit

EGC Equal Gain Combining

ECU Environment Control Unit

EDGE Enhanced Data rates for GSM Evolution

EPLD Erasable Programmable Logic Device

ETP Extend Test Port

ETRM Transceiver Module for Edge

F

FCDU “F”Combiner Distribution Unit

FCLK Frame Clock

FCM Fan Control Module

FUL Frame Unit LAPD

G

GCDU “G”Combiner Distribution Unit

GPRS General Packet Radio Service

GSM Globe System for Mobile communication

H

HCDU “H”Combiner Distribution Unit

HDB3 High Degree Bipolar coding

HDLC High Level Data Link Controller

HW High Way

I

ICDU “I” Combiner Distribution Unit

IRC Interference Rejection Combining

L

LapD Link Access Procedure “D” Channel

LapDm Link Access Procedure “Dm”(mobile “D”)Channel

LM Local Manager

LMT Local Maintenance Terminal (LMT)

LNA Low Noise Amplifier

LO Local Oscillator

LPF Loop Filter

LVDS Low Voltage Differential Signaling

Page 119: B8018 tecnical

Appendix A –Abbreviation

Confidential and Proprietary Information of ZTE CORPORATION 107

Abbreviations Full name

M

MAC Medium Access Control

McBSP Multi-channel Buffer Serial Port

MMI Man-Machine Interface

MO Manage Object

MRC Maximum Ratio Combining

MS Mobile Station

MSS Mobile Switching System

MTBF Mean Time Between Failures

N

NACC Network Assisted Cell Change

O

OAMM Operational And Maintenance Module

OBCLK Octet Binary clock

OMC Operation and Maintenance Center

P

PA Power Amplifier

PAU Power Amplifier Unit

PCM Pulse Code Modulation

PCU Packet Control Unit

PDM Power Distribution Module

PLMN Public Land Mobile Network

PS Packet Switched

PTCCH Packet Timing Control Channel

Q

QoS Quality of Service

R

RCU Radio Carrier Unit

RDU Receiver Distribute Unit

RF Radio Frequency

Rx Receiver

S

SMC Short Message Center

SPAU Super Power Amplifier Unit

STRM Super Transceiver Unit

T

Page 120: B8018 tecnical

ZXG10 B8018 (V1.00) In-Door Base Transceiver Station Technical Manual

108 Confidential and Proprietary Information of ZTE CORPORATION

Abbreviations Full name

TA Time Advance

TC Transcoder

TCH Traffic Channel

TCI Thin Chip Integration

TDMA Time Division Multiple Access

TEI Terminal Endpoint Identifier

TFO Tandem Free Operation

TPF Tracking Phase lock Frequency synthesizer

TPU Transceiver Process Unit

TRM Transceiver Module

TRX Transceivers

Tx Transmitter

U

Um Um

V

VCO Voltage Control Oscillator

VSWR Voltage Standing Wave Ratio

Page 121: B8018 tecnical

Confidential and Proprietary Information of ZTE CORPORATION 109

A p p e n d i x B

Figures

Figure 1 – GSM Network.....................................................2 Figure 2 – ZXG10 B8018 (V1.00) in a GSM/GPRS Network .......3 Figure 3 - Circuit Service Protocol Hierarchy of Um Interface ....4 Figure 4 - Packet Service Protocol Stack Structure of Um Interface ...........................................................................4 Figure 5 - Circuit service Structure of Abis Interface ................6 Figure 6 - Example of Abis Interface Timeslot Configuration......7 Figure 7 – ZXG10 B8018 (V1.00) System Structure.................8 Figure 8 – ZXG10 B8018 (V1.00) Cabinet ............................ 25 Figure 9 - Single Cabinet with Full Configuration ................... 26 Figure 10 – Clock Distribution in ZXG10 B8018 (V1.00) ......... 28 Figure 11 – Time Slot Switching in ZXG10 B8018 (V1.00) ...... 28 Figure 12 – Rack Layout .................................................... 29 Figure 13 – ZXG10 B8018 (V1.00) Hardware Structure .......... 30 Figure 14 – ZXG10 B8018 (V1.00) Software Structure ........... 32 Figure 15 – dCMM Block Diagram........................................ 32 Figure 16 – dFUC Software Block Diagram ........................... 34 Figure 17 - FIU Software Sub-system Block Diagram ............. 35 Figure 18 - ZXG10 B8018 (V1.00) Signaling Flow.................. 36 Figure 19 – Cabinet Structure ............................................ 39 Figure 20 - Cabinet Top Layout........................................... 40 Figure 21 - Top Shelf Full Configuration ............................... 50 Figure 22 - Modules in the Carrier Shelf ............................... 51 Figure 23 - Structure of Fan Shelf ....................................... 52 Figure 24 - Air Filter Shelf Structure.................................... 52 Figure 25 - Cabinet-Top DIP Switches.................................. 54

Page 122: B8018 tecnical

ZXG10 B8018 (V1.00) In-Door Base Transceiver Station Technical Manual

110 Confidential and Proprietary Information of ZTE CORPORATION

Figure 26 – CMB Functional Diagram................................... 57 Figure 27 – CMB Panel ...................................................... 57 Figure 28 - Local Operation and Maintenance of ZXG10 B8018 (V1.00)........................................................................... 60 Figure 29 - Board Layout Showing DIP Switches ................... 60 Figure 30 – EIB Functional Diagram .................................... 61 Figure 31 - EIB Panel ........................................................ 62 Figure 32 - Board Layout Showing DIP Switches ................... 62 Figure 33 - PDM Functional diagram.................................... 63 Figure 34 - PDM Panel....................................................... 64 Figure 35 – DTRU Panel..................................................... 66 Figure 36 - AEM Location in the System............................... 67 Figure 37 - Functional Blocks of the CDU ............................. 71 Figure 38 - CDUG Panel Structure....................................... 72 Figure 39 – ECDU Functional Blocks .................................... 74 Figure 40 - ECDU panel ..................................................... 75 Figure 41 - CEU Functional Blocks....................................... 77 Figure 42 - Structure of CEU Panel...................................... 78 Figure 43 – CEUG/2 Panel.................................................. 79 Figure 44 – CEN Functional Blocks ...................................... 80 Figure 45 – CEN/2 Functional Blocks ................................... 81 Figure 46 - CENG Panel ..................................................... 82 Figure 47 - CEN/2 Panel .................................................... 83 Figure 48 – Star Networking Schematic Diagram................... 87 Figure 49 – Chain Networking Schematic Diagram................. 88 Figure 50 – Tree-Networking Schematic Diagram.................. 88 Figure 51 - Ring-Networking Schematic Diagram .................. 89 Figure 52 – Location of CEU/2, CEN/3 and CEN/4.................. 90 Figure 53 – Configuration with Two ECDUs........................... 91 Figure 54 - Logical Connections of Configuration with Two ECDUs..................................................................................... 91 Figure 55 - Configuration with Two CDUs and TMAs............... 92 Figure 56 - Logical Connections of Configuration with two CDUs and TMAs ........................................................................ 92 Figure 57 – S2/2/2 Site Configuration with DPCT .................. 93 Figure 58 – Two Carriers per Sector Antenna Feeder Configuration (Through Combiner)...................................... 93

Page 123: B8018 tecnical

Appendix B –Figures

Confidential and Proprietary Information of ZTE CORPORATION 111

Figure 59 – Logical Connections of Two Carriers per Sector Antenna Feeder Configuration (Through Combiner) ............... 94 Figure 60 - Four Carriers per Sector Antenna Feeder Configuration................................................................... 94 Figure 61 - Logical Connections of Four Carriers per Sector Antenna Feeder Configuration ............................................ 95 Figure 62 - Six Carriers per Sector Antenna Feeder Configuration (Using CEU)..................................................................... 95 Figure 63 – Logical Connections of Six Carriers per Sector Antenna Feeder Configuration (Using CEU)........................... 96 Figure 64 – Six Carriers per Sector Antenna Feeder Configuration (Using CEN/2) .............................................. 96 Figure 65 – Logical Connections of Six Carriers per Sector Antenna Feeder Configuration (Using CEN/2)........................ 97 Figure 66 – Dual Band Configuration Using Four-Port Antenna 98 Figure 67 - Four-port Antenna Feeder Connections ................ 98 Figure 68 - Dual Band Configuration Using Two-Port Antenna . 99 Figure 69 – Two-port Antenna Feeder Connections .............. 100 Figure 70 – S 8/8/8 Configuration Cabinet Structure............ 101 Figure 71 – S 8/8/8 Configuration..................................... 102 Figure 72 – S 8/8/8 Configuration Logical Connections......... 103

Page 124: B8018 tecnical

ZXG10 B8018 (V1.00) In-Door Base Transceiver Station Technical Manual

112 Confidential and Proprietary Information of ZTE CORPORATION

This page is intentionally blank.

Page 125: B8018 tecnical

Confidential and Proprietary Information of ZTE CORPORATION 113

Tables

Table 1 - Chapter Summary .................................................x Table 2 - Typographical Conventions .................................... xi Table 3 - Mouse Operation Conventions ................................ xi Table 4 – ZXG10 B8018 (V1.00) Working Frequency Bands .... 15 Table 5 – ZXG10 B8018 (V1.00) Channel Configuration ......... 16 Table 6 - Duplex Transceiver Interval .................................. 16 Table 7 – ZXG10 B8018 (V1.00) Physical Characteristics........ 17 Table 8 - ZXG10 B8018 (V1.00) Voltage and Power Consumption..................................................................................... 17 Table 9 – ZXG10 B8018 (V1.00) Heat Dissipation.................. 18 Table 10 – ZXG10 B8018 (V1.00) Environmental Characteristics..................................................................................... 18 Table 11 – ZXG10 B8018 (V1.00) Clock Specifications ........... 19 Table 12 – ZXG10 B8018 (V1.00) Reliability Specifications ..... 19 Table 13 - Abis Interface Basic Requirements ....................... 20 Table 14 - Abis Interface Electrical Features ......................... 21 Table 15 - Function Descriptions of Hardware Parts ............... 31 Table 16 - Interfaces on the Cabinet Top ............................. 41 Table 17 - Primary Power Interface Signal Description ........... 41 Table 18 - Signal Description of PWRTA_1............................ 42 Table 19 - Signal Description of PWRTA_2............................ 43 Table 20 - Signal Description of PWRTA_3............................ 43 Table 21 - Signal Description of the Main Contact Point Signal Interface ......................................................................... 45 Table 22 - Site ID Interface Signal Description...................... 47 Table 23 - E1 Interface Signal Description............................ 47 Table 24 - Inter-Cabinet Synchronization Signal Interface Signal Description ...................................................................... 49 Table 25 - Signal Description of the MMI Interface ................ 50 Table 26 – CMB Panel LEDs................................................ 57

Page 126: B8018 tecnical

ZXG10 B8018 (V1.00) In-Door Base Transceiver Station Technical Manual

114 Confidential and Proprietary Information of ZTE CORPORATION

Table 27 – Buttons and Switch on CMB Panel ....................... 59 Table 28 – S7 DIP Switches ............................................... 60 Table 29 – S10 DIP Switches ............................................. 61 Table 30 - DIP Switches Meanings ...................................... 62 Table 31 - DIP Switches Working Modes .............................. 62 Table 32 - Types of DTRUS ................................................ 64 Table 33 – DTRU Panel LEDs .............................................. 66 Table 34 - DTRU External Interfaces ................................... 66 Table 35 - Types of AEMs (According to CDU Type) ............... 68 Table 36 - Types of AEMs (According to Working Band).......... 68 Table 37 - Comparison Between Different CEUs and CENs ...... 69 Table 38 – CDUG External Interfaces................................... 72 Table 39 - CDU Panel LEDs ................................................ 73 Table 40 – ECUG External Interfaces ................................... 75 Table 41 - ECDU Panel LEDs .............................................. 76 Table 42 – CEU External Interfaces ..................................... 79 Table 43 – Modules for Different Frequencies........................ 89

Page 127: B8018 tecnical

Confidential and Proprietary Information of ZTE CORPORATION 115

Index

100 Mbps Ethernet interface .29 13 M test interface ..............45 8PSK.................................25 Abis interface .......................5

Balanced input mode .........5 Layer-1............................6 Layer-2............................6 Layer-3............................6 Relevant protocols .............6 Unbalanced input mode......5

Abis interface processing........8 Abis interface specification ...22 Abis interface timeslot ...........6 Abis interface types .............29 Advanced flow control..........13 AI Power Control.................15 Air pollution .......................21 AM suppression...................25 Antenna feeder interface ......43 AoIP..................................15 ARFCN...............................18 Atmospheric pressure ..........21 Automatic crossover ............14 Availability Ratio (A)............22 Average Interruption time per

year ..............................22 Base height........................19 BBCM ................................54 BER ..................................25 Bit rate (approximate) .........22 Bit rate tolerance ................22 C/I ratio ............................23 Cabinet..............................26 Capacity ............................21 Capacity expansion .............13 Carrier power .....................24 CCComm ...........................61 Channel coding/decoding .....35 Channel configuration ..........18

1800 MHz.......................18 1900 MHz.......................18 850 MHz ........................18 900 MHz ........................18 Extended 900 MHz...........18

Channel decoding.......... 24, 25 Channel encoding................25 Channel interval..................18 Circuit-type data service ......11 Circuit-type voice services ....11

Clock ................................ 21 Clock accuracy................ 21 Initial maximum frequency

bias ........................... 22 Maximum frequency bias.. 21 Pull-in range................... 21

Clock distribution................ 28 Clock synchronization.......... 28 CMB.................................. 61 CMComm........................... 61 CMM ................................. 61 Color................................. 19 Configuration

Dual-Band Configuration .. 93 Four Carriers per sector ... 90 S 8/8/8 Configuration

Example..................... 96 Single carrier per sector ... 86 Six Carriers per sector ..... 91 Two Carriers per sector

(Through Combiner) .... 89 Two Carriers per sector (with

DPCT)........................ 88 De-interleaving................... 25 Delay Diversity Transmission

(DDT)............................ 15 Dimensions........................ 19 DIP switch ....................85, 86 Diversities ......................... 12 Downlink .............................8 D-socket..............................5 Dual Power Combining

Transmission (DPCT) ....... 14 Duplex transceiver interval... 18

1800 MHz ...................... 18 1900 MHz ...................... 18 850 MHz ........................ 18 900 MHz ........................ 18 Extended 900 MHz .......... 18

E1 60 E1 connection .................... 84 E1 interface ....................... 48 E1/T1 interface...13, 29, 31, 33 E1/T1 Interface Board (EIB) . 31 EAM....................................8 Electromagnetic security (EMC)

.................................... 22 Environmental characteristics21 Equal Gain Combining (ECG) 15

Page 128: B8018 tecnical

ZXG10 B8018 (V1.00) In-Door Base Transceiver Station Technical Manual

116 Confidential and Proprietary Information of ZTE CORPORATION

Equalizer decryption ........... 25 ETP .................................. 61 Exploded View ................... 40 External environment

monitoring interface ........ 45 External interfaces.5, 4, 61, 69,

74, 77, 80 Fan Control Module..... See FCM Fast Ethernet Interface Board

(FIB)............................. 31 FCLK test interface ............. 45 FCM.................................100 Frequency bands ................ 17

1800 MHz ...................... 17 1900 MHz ...................... 17 850 MHz........................ 17 900 MHz........................ 17 Extended 900 MHz .......... 17

Frequency error ................. 24 Frequency hopping ............. 13 FUL .................................... 8 GMSK ............................... 25 Grounding interface (PE) ..... 45 Grounding resistance .......... 20 GSM 08.52 .......................... 6 GSM 08.54 .......................... 6 GSM 08.56 .......................... 6 GSM 08.58 .......................... 6 GSM 12.21 .......................... 6 GSM Network....................... 2 GSM standards................... 12 Handovers types ................ 14 Hardware structure............. 31 Heat dissipation ................. 20 Hierarchical model ................ 4 High receiving sensitivity ..... 19 Humidity ........................... 21 HYCOM1............................ 43 HYCOM2............................ 43 HYCOM3............................ 43 HYCOM4............................ 43 HYCOM5............................ 43 HYCOM6............................ 43 Inner illumination ............... 21 Interference ...................... 25 Interference protection ratio 23 Interference Rejection

Combining (IRC)............. 15 Inter-modulation suppression25 Inter-rack synchronization ... 50 ITU-T G.703 ...................... 22 ITU-T G.704 ...................... 22 LNA.................................100 Local O&M interface ............ 51 LVDS ...............................100 Material used ..................... 19 Maximum Ratio Combining

(MRC) ........................... 15 Modulation ........................ 25 MTBF ................................ 22

MTTR ................................22 Multiplexing........................25 Networking modes ..............13

Chain networking ............84 Ring networking ..............86 Star networking ..............84 Tree networking ..............85

One-site multi-BTS..............85 Output power .....................19 PAU................................. 101 PDM ................................ 101 Phase error ........................24 Physical characteristics ........19 PLMN...................................4 Power Amplifier................. 101 Power consumption .............20 Power Distribution Module .. See

PDM Protocol hierarchy .................4 Protocol stack.......................4 Rayleigh fading ...................13 RCU ................................ 101 RDU ................................ 101 Receiver ...................... 24, 25 Receiver performance ..........24 Receiving sensitivity ............19 Reliability...........................22 RF 101 RST...................................61 Sensitivity level ..................25 Signal code pattern .............22 Site ID interface..................47 Software sub-system

dCHP ....................... 34, 35 dCMM ............................34 dFUC ....................... 34, 36 FIU.......................... 34, 37

Software sub-systems..........34 Spurious emission ...............25 Supports functions ..............11 System Background...............1 System capacity..................11 System structure ..................9 System throughput..............12 TCH ....................................8 TCH services ......................12 Temperature ......................21 Time slot switching..............30 Tower mounted amplifier

interface ........................43 TPU................................. 101 Transmitter performance......24 TRM ................................ 101 Um interface ........................4

Layer-1............................5 Layer-2............................5 Layer-3............................5

Um interface specification.....23 Uplink .................................8 Voltage consumption ...........20

Page 129: B8018 tecnical

Appendix B –Index

Confidential and Proprietary Information of ZTE CORPORATION 117

Weight ..............................19 Weight bearing capacity .......19 Wireless channel .................23

Wireless RF modulation ....... 24 Working principle................ 38