AVINA Infant CPAP Units AVINA Bubble CPAP AVINA Bubble CPAP unit is a neonatal pressure-metric, continuous flow, portable CPAP unit for distressed new born or premature babies (up to 20 Kg). It does the treatment at continuous positive pressure. The use of Bubble CPAP can limit the development of Broncho pulmonary dysplasia(BPD) and provides oscillations which may have some physiological benefit to pre-mature lungs.

Upload: avihealthcare

Post on 24-Jul-2015

588 views

Category:

Healthcare


0 download

TRANSCRIPT

AVINA Infant CPAP Units

AVINA Bubble CPAP

AVINA Bubble CPAP unit is a neonatal pressure-metric, continuous flow, portable CPAP unit for distressed new born or premature babies (up to 20 Kg).

It does the treatment at continuous positive pressure.

The use of Bubble CPAP can limit the development of Broncho pulmonary dysplasia(BPD) and provides oscillations which may have some physiological benefit to pre-mature lungs.

Neonatal Delivery Unit with Air-O2 Mixer

AVINA Easy Resuscitation Unit acts as Neonatal Delivery Unit consisting of Air-O2 Flowmeter based Mixer, Pressure Manometer, Pressure Limiting Valve.

Bubble CPAP Generator

Rotating Pressure Adjustment Lever Gas discharge ports direct gas away 360 Swivel inlet connector Water level adjustment port allows water to be added or removed without disconnecting expiratory circuit

CPAP Pressure - 0 to 10 cmH2O

PARTS

Technical Specifications:

Dimensions : W135 x D170 x H 156 mm Heater wire capacity: 60W max

Heater plate capacity: 150W, 110? Max

Heater Plate Overheat :Cutoff: 118±6?

Servo Humidifier

• Dual Temp control both Chamber & Airway

• High/Low alarm both airway & chamber

• Heater wire mode offer optimal humidity & less water condensation.

Temperature Control:

Invasive mode: Chamber outlet 37Deg C Airway 40Deg C

Noninvasive mode: Chamber outlet 31Deg C Airway 34Deg C

CPAP Interface

Nasal ProngsNasal Prongs are reusable, soft silicone make, comfortable and low resistance

Three Sizes Available - Small, Med, Large

Infant Bonnet is made up of Cotton, and is latex free.

Heated Wire CircuitsReusable and Disposable Heated Wire Breathing Circuits and Non Heated Wire Circuits available

Air Oxygen Blender

Air Oxygen Blender mixes Air and Oxygen in proportion decided by the knob Setting

AVINA DigiCPAP• WORKING : Inbuilt Valve Based Continuous Flow

• DISPLAY : Digital Display for FiO2, MAP and CPAP

• AIR FLOW : 0 to 20 lpm Calibrated

• O2 FLOW : 0 to 20 lpm Calibrated

• CPAP : 0 to 30 cmH2O

• MAP : 5 to 40 cmH2O (Max Pressure)

• BATTERY : 2 hours Battery Backup

• FiO2 : Inbuilt Oxygen Sensor - 21% to 100%

• ALARMS : High/Low Pressure, High/Low FiO2, Apnea, Battery Low

• APNEA : Apnea Detection settable betn 10-20 sec

AVINA EasyCPAP

• WORKING : Inbuilt Valve Based Continuous Flow

• DISPLAY : Pressure Guage -20 to 100 cmH2O

• AIR FLOW : 0 to 20 lpm Calibrated

• O2 FLOW : 0 to 20 lpm Calibrated

• CPAP : 0 to 30 cmH2O

• MAP : 5 to 40 cmH2O (Max Pressure)

COMMON FEATURES•Inbu

ilt nCPAP Driver produces constant, stable and accurate CPAP Pressure with its unique valve design

Inbuilt CPAP Generation

•Apnea time can be set between 10 sec to 30 sec. Breath is only detected when baby’s effort crosses the Trigger level set above CPAP Pressure.

Apnea Detection and Alarm

•Safety against over pressure is provided by setting MAP or Maximum Applied Pressure or PIP (Peak Inspiratory Pressure)

Maximum Pressure Limit – MAP

•High, Low CPAP Pressure alarm indications, High and low Oxygen Alarm indication,Battery Low Indication

Automatically Set Safety Features

NEONATAL RESUSCITATION ACCESSORIES

Infant / Child Resuscitation Kitincluding Ambubag, Oxygen Face mask, Non-breathing valve, Reservoir Hose, Reservoir Bag all in a case

Jointless Oxygen HOOD (Polycarbonate) – Available in two sizes

Reusable NASAL ProngsAvailable in three sizes

Laryngoscope SetPenlite handle with 3 Miller Blade sizes - 00, 0 & 1

Oxygen (FiO2) AnalyzerSlow Suction Unit

Head Immobiliser

THANK YOU

AVI Healthcare Private Limited

Factory:25, Nanddeep Industrial Estate, Kondivita Lane, Near JB Nagar,Andheri East, Mumbai - 400059

Mobile: +91 9322294345, +91 9820228952

Landline: +91 22 28326240 / +91 22 28320452 / +91 66926066

Email id: [email protected] / [email protected]