automation products catalog
TRANSCRIPT
This catalog will be periodically updated with new and updated pages. The
current version and update packages can be found on our website
www.pamensky.com or can be requested from V.J. Pamensky Canada Inc.
1 877 PAMENSKY.
PAMENSKY
Automation ProductsVariable Frequency Drives
Soft Starters
Panels
Industrial Control Products
101
TERMS AND CONDITIONS OF SALE V.J. PAMENSKY CANADA INC.
1. EXCLUSIVE CONDITIONS OF SALE: This Quotation or Order is subject to terms and conditions contained here-in and supersedes
Buyer’s Specifi cation and/or Purchase Order. Seller will recognize no modifi cations or additions to these conditionsunless specifi cally
agreed to in writing by Seller. Failure of Seller to object to provisions contained in the Purchaser’s Order or any other communication
from Buyer shall not be construed as a waiver of these conditions or an acceptance of any such provisions. If Buyer places an Order
with Seller based on Seller’s Quotation, whether the Order is placed in writing or orally, then the Quotation (including Seller’s terms and
conditions) and the Seller’s acceptance of the Order will constitute the entire contract between Buyer and Seller with respect to the
subject matter thereof notwithstanding any terms and conditions inconsistent with these terms and conditions on any of Buyer’s forms
or correspondence. All orders, sales contracts and other documentation between Buyer and Seller shall become effective only when
approved and accepted by the Seller.
2. PRICES: Prices quoted herein are based upon presently prevailing duties, rates of duties, taxes, special assessments, monetary
exchange and freight as applied to materials and/or equipment purchased or imported by Seller. Seller reserves the right to amend the
price(s) in this quotation where variations in regulated costs such as rate of duties, taxes, special assessments, monetaryexchange and
freight between the date of quotation and date of delivery are deemed signifi cant by the Seller.
3. TERMS OF PAYMENT: The standard terms of payment are Net-30 Days from date of invoice, with a service and interest charge of
1-1/2% per month (18% per annum) on past due invoices applying. If Buyer defaults in any payment when due or refuses to accept
delivery or becomes insolvent, the Seller at its option, without prejudice to other lawful remedies, may defer deliveries or cancel the re-
mainder of the order. Equipment held for Buyer shall be at the risk and expense of Buyer and payment shall become due from the date
of which Seller is prepared to make shipment. Printed terms on face of our Quotation will take precedence.
4. TITLE: Title to the goods covered by this Quotation and the right to immediate possession thereof shall remain with the Seller until the
purchase price is paid in full and Buyer hereby grants to Seller a security interest in the equipment (and all proceeds thereof) to secure
the Buyer’s obligation to pay for the equipment.
5. CERTIFICATIONS AND TAXES: Prices do not include sales, use or other similar federal, state or local taxes. Any certifi cation for
special duty or tax rate must be supplied at time of order. A service charge will be applied on any credit notes necessitated by the Buyer
not providing proper certifi cation at time of order. Exception from taxes extended to the buyer does not prejudice our right to charge
the buyer with taxes plus any penalties assessed at any subsequent date should the taxing authorities determinethat the equipment is
taxable.
6. PENALTIES AND DELAYS: No penalty clause of any kind, in any specifi cation of order will be effective unless specifi cally approved
in writing by Seller. Seller shall not be liable for any damage, expenses or consequential damages caused by delays beyond Seller’s
control including without limiting the generality of the foregoing; fi re, strike, act of the Buyer, restriction by civil or military authority, Act
of God, transportation failures or inability to obtain labor, materials or manufacturing facilities. In the event of any such delay, the date of
delivery shall be extended for a period equal to the time lost by reason of the delay.
7. CANCELLATION: Orders once accepted are not subject to cancellation unless on terms that will indemnify Seller against loss and/or
expenses incurred.
8. SHIPMENT: Unless otherwise specifi ed in writing, all shipments are EX-WORKS (Incoterms 2000) Seller’s shop, in which case Seller
is not responsible for damage, apparent or concealed, or loss in transit and all claims on “collect” shipments must be made by Buyer
direct to the carrier. Seller will assist insofar as practical in securing satisfactory adjustment to reasonable claims.
9. ACCEPTANCE, INSPECTION: By virtue of Buyer issuing an order for equipment in accordance with this Quotation, he also accepts
Seller’s Terms and Conditions as part of the order. Buyer shall inspect the goods immediately upon the receipt thereof. All claims by
Buyer (including claims for shortages), except only those provided for under the WARRANTY clauses below, must be asserted in writing
by Buyer within a 10 day period or they are waived. If this contract involves partial performances, all such claims must be asserted
within a 10-day period for each partial performance.
10. WARRANTY: Seller warrants to the Buyer that its products are free from defects in workmanship and materials when operated un-
der normal conditions and in accordance with nameplate characteristic limits. This warranty will be in effect for the following time period
and for the following products:
Low voltage standard effi ciency motors NEMA & IEC frames are warranted for a period of 12 months from date of installation, but not
more than 18 months from date of manufacture.
EPACT & NEMA Premium Effi ciency motors both NEMA & IEC frames are warranted for a period of 24 months from date of installation
but for not more than 30 months from date of manufacture.
IEEE841 motors are warranted for a period of 60 months from date of installation but for not more than 66 months from date of manu-
facture.
Machines & Generators are warranted for a period of 12 months from date of installation, but not more than 18 months from date of
manufacture. These products include but are not limited to; Above NEMA size Motors: low voltage, medium voltage and high voltage,
DC motors, Turbo Generators, Hydro Generators, Synchronous Motors, and Wound Rotor Motors.
Automation products (variable frequency drives and soft starters) and Electrical components are warranted for a period of 12months
from date of installation, but not more than 18 months from date of manufacture. If any defects are claimed by the Buyer during the
101
warranty period, Seller’s sole obligation shall be limited to alteration, repair or replacement at Seller’s expense, EX-WORKS (Incoterms
2000) Seller’s shop, on parts or equipment which upon return to Buyer and upon Buyer’s examination prove to be defective.
UNLESS OTHERWISE SPECIFIED IN WRITING HEREIN, THERE ARE NO REPRESENTATION, WARRANTIES OR CONDITIONS,
EXPRESSED OR IMPLIED STATUTORY OR OTHERWISE, EXCEPT FOR THE FOREGOING AND WITHOUT LIMITING THE GENERAL-
ITY OF THE ABOVE, THERE ARE NO EXPRESS OR IMPLIED REPRESENTATIONS OR WARRANTIES CONCERNING THE QUALITY
OF THE EQUIPMENT OR THAT ANY SUCH EQUIPMENT WILL BE FIT FOR ANY PARTICULAR PURPOSE OF THE PURCHASER. THE
SELLER SHALL HAVE NO OBLIGATION TO REPAIR OR REPLACE SUCH PRODUCTS OR PARTS UNLESS IT RECEIVES AT ITS OF-
FICES IN CANADA WRITTEN NOTICE OF SUCH DEFECT WITHIN THE ABOVE-MENTIONED WARRANTY PERIOD.
This warranty does not cover the cost of transportation, labor, removal, installation, or re-testing of the new or repaired goods or parts,
or any other direct or incidental expenses incurred in shipping the product to or from Seller. Replacement goods or parts are war-
ranted for the remainder of the warranty period applicable to the goods originally supplied by the seller. No warranty shall apply to any
equipment upon which repairs or alterations have been made unless authorized by Seller, nor to equipment which hasbeen subjected to
misuse, negligence or mishandling.
11. DAMAGES: Subject to the balance of the provisions of this clause, Seller shall only be liable for the cost of replacement of any de-
fective Equipment provided hereunder. Seller shall not be liable to the Buyer in any circumstances for any incidental, special, consequen-
tial or indirect damages, including but not limited to loss of profi ts or revenue, loss of use of equipment and facilities, and claims by or
payments to customers, suppliers or other parties who have a relationship with the Buyer. This disclaimer applies to consequential dam-
ages based upon any cause of action whatever asserted against Seller including causes of action arising out ofany breach of warranty,
express or implied, guarantee, product liability, negligence, tort, or any other cause pertaining to the performance or non-performance
of this Quotation or contract by Seller and the Buyer hereby waives any right to claim punitive,aggravated or exemplary damages with
respect to a breach of this Quotation or the performance or non-performance of the Equipment, and whether such claim is founded in
contract, tort or otherwise. Seller shall not be responsible for losses or damages arising out of the negligence of the Buyer, its’ employ-
ees, agents or third party contractors. In no event will Sellers maximumliability to the Purchaser in connection with the Equipment, in-
cluding without limitation resulting from breach of contract or any other performance or non-performance of this Quotation or contract,
exceed the amount of the purchase price paid to Seller hereunder.
12. RETURNING EQUIPMENT: No equipment is to be returned without fi rst obtaining from Seller shipping instructions and a return
material identifi cation number and agreement in writing as to terms. Returned equipment, which Seller elects to accept for credit is sub-
ject to reasonable handling and restocking charge commensurate with the policy of the manufacturer plus all charges incurred by Seller.
Seller is not responsible for equipment that is returned without complying with the foregoing. Equipment isreturned at the expense and
risk of the Buyer. Returned equipment must be in the original packaging and unused.
13. PRIVILEGE AND LIEN RIGHTS: Seller retains all lien rights with regard to the equipment in accordance with any Builder’s Lien Act,
Mechanic’s Lien Act, Builder and Works Act or other legislation passed pursuant to or in replacement thereof.
14. BACK CHARGES: Seller will accept no back charges for any reason without Seller’s written permission to incur such back charges.
15. TECHNICAL ADVICE: Any technical advice furnished or recommendation made by Seller or any representative of Seller concerning
any use or application of any of the goods is believed to be reliable, but SELLER MAKES NO WARRANTY, EXPRESSED OR IMPLIED,
ON RESULTS TO BE OBTAINED. BUYER ASSUMES ALL RESPONSIBILITY FOR LOSS OR DAMAGE RESULTING FROM THE HAN-
DLING OR USE OF ANY OF THE GOODS.
16. INVALIDITY: If any provision of this contract shall be found to be invalid or illegal by reason of any determination made by a court of
competent jurisdiction or any governmental authority having jurisdiction in the circumstances, such provisions shall be severed from this
contract to the extent of such invalidity or illegality and the validity, legality or enforceability of the remaining provisions of this contract
shall not in way be affected or impaired thereby. Waiver of any default shall not be a waiver of any other or subsequent default.
17. GST NUMBER: V.J. Pamensky Canada Inc. GST Number is 105553648
18. APPLICABLE LAWS AND FORUM: This contract shall be interpreted in accordance with and shall be governed by the laws of
the Province of Ontario, and the parties agree that any disputes hereunder or with respect to this quotation or the resulting contract
between the parties shall be determined exclusively by the Courts in the Province of Ontario, and the parties hereby expressly attorn to
the exclusive jurisdiction of the Courts in the Province of Ontario.
19. LANGUAGE: The parties acknowledge that they have required that this contract and all related documents be prepared in English.
Les parties reconnaissent avoir exige que la présente convention et tous les documents connexes solent rédigés en anglais. If the Buyer
requests, a French version of this agreement will be used.
20. LIABILITY: Notwithstanding anything to the contrary herein contained, the Liability of the Seller under any circumstances whatso-
ever and without exception shall be limited to the Purchase Price of the particular item forming part of the goods.
102
Table of Contents
Variable Frequency DrivesCFW 08 Plus - Low Voltage VFD 1.1
CFW 08 Wash - Low Voltage NEMA 4X VFD 1.4
CFW 09 - Low Voltage VFD 1.8
CFW 09 Shark - Low Voltage NEMA 4X VFD 1.12
CFW 10 - Low Voltage VFD 1.18
CFW 11 - Low Voltage VFD 1.21
CFW 11M - - Low Voltage Modular VFD 1.30
CFW 700 - Low Voltage VFD 1.38
CFW 701 - Low Voltage HVAC VFD 1.43
MVW 01 - Medium Voltage VFD 1.50
MVW 01 - Compact Medium Voltage VFD 1.53
Soft StartersSSW 05 Plus - Low Voltage Soft Starter 2.1
SSW 06 - Low Voltage Soft Starter 2.5
SSW 07 - Low Voltage Soft Starter 2.13
PanelsEDP - Enclosed Drive Panels 3.1
GPH - Combination Soft Starter 3.4
Industrial Control ProductsPESW - Enclosed Motor Starters 4.1
CWC - Miniature Contactors 4.8
CWM - Standard Contactors 4.13
RW - Thermal Overload Relays 4.25
MPW - Manual Motor Protector 4.30
Pushbuttons and Pilot Lights 4.37
ReferenceVariable Frequency Drive Sizing Guide 5.1
Direct On-Line Starters Sizing Guide 5.8
Soft Starters Sizing Guide 5.10
Version: CAN.AUT.09.2013
www.pamensky.com
101
1.1Variable Frequency Drives
www.pamensky.com
CFW 08 Plus - VFD - Features
The WEG CFW-08 line of VFD‘s offers Single
and Three Phase Input Power Supply options for
motors up to 20HP. Outstanding features and
options in a NEMA 1 enclosure allow the CFW08
Plus to be successfully used in a large variety of
applications.
Standard Features
• V/Hz or Sensorless Vector Control
• NEMA 1 Enclosure
• Single and Three-phase input voltage
• 200-240V, 380-480V or 500-600V input
voltage, 50 - 60 Hz
• 150% current overload capacity
• 16 bit DSP controlled PWM output
• 2.5 / 5 / 10 / 15 kHz adjustable swiching
frequency
• Four isolated programmable digital inputs
• Two programmable relay outputs
• Two isolated programmable analog inputs
(with special function)
• One analog output
• Protective features: Over current, motor
overload, drive over temperature, output
phase-to-phase and phase-to-ground short
circuit, DC bus over and under voltage and
external fault
• Control features: Linear and “S” ramp
acceleration and deceleration, local/remote
control, DC braking, torque boost, motor slip
compensation, electronic pot, preset speeds,
adjustable V/Hz profi le, maximum and
minimum adjustable frequency limits, two skip
frequencies, adjustable output current limit,
JOG, ride-thru, fl ying start and PID regulator.
• Display readings: Motor speed, frequency,
voltage, current, last fault, heatsink
temperature and drive status
• Ambient: 32ºF (0ºC) to 104ºF (40ºC), 3300ft
(1000m) altitude, 90% humidity,
non-condensing
Optional Features
• Dynamic Braking capabilities available
• Remote Keypad with Copy Function
• RS-232 or RS-485 Serial Interface
• Modbus Communication*
• DIN rail mounting through 2HP
*Requires optional RS-232 or RS-485 Interface
Applications
• Pumps
• Fans
• Blowers
• Conveyors
• Rollout tables
• Agitators
• Mixers
101
Variable Frequency Drives1.2
www.pamensky.com
CFW-08 - Part Number Specifi cation
1 2 3 4 5 6 7 8 9 13121110
S3H1DNA1DBSI--OP3848T0016 CFW08
1. CFW-08 Variable Frequency Drive
2. Output Rated Current 220-240V 380-480V 500-600V
0016 = 1.6 A
0026 = 2.6 A
0040 = 4.0 A
0070 = 7.0 A
0073 = 7.3 A
0100 = 10 A
0160 = 16 A
0220 = 22 A
0280 = 28 A
0330 = 33 A
0010 = 1.0 A
0016 = 1.6 A
0026 = 2.6 A
0027 = 2.7 A
0040 = 4.0 A
0043 = 4.3 A
0065 = 6.5 A
0100 = 10 A
0130 = 13 A
0160 = 16 A
0240 = 24 A
0300 = 30 A
0017 = 1.7 A
0030 = 3.0 A
0043 = 4.3 A
0070 = 7.0 A
0100 = 10 A
0120 = 12 A
* Selection Table for 2
3. Power Supply: S = single-phase
T = three-phase
B = single-phase or three-phase
4. Power Supply Voltage: 2024 = 200-240 V
3848 = 380-480 V
5060 = 500-600 V
5. Language: P = Portuguese
E = English
G = German
S = Spanish
6. Product Version: S = Standard
O = With options
7. Enclosure: blank = Standard (see technical specifi cations table)
N1 = NEMA 1
N4 = NEMA 4X
8. HMI - Human Machine Interface:
blank = standard
SI = without HMI
9. Control Board: blank = standard (CFW-08 Standard)
A1 = control 1 (CFW-08 PLUS)
A2 = control 2 (CFW-08 Plus with bipolar analog inputs)
A3 = CANopen (1)
A4 = DeviceNet (1)
A5 = Pumps
10. EMI Filter: blank = without fi lter
FA = Internal Class A fi lter
11. Special Hardware: Blank = not provided
Hx = X version special hardware
12. Special Software: Blank = not provided
Sx = X version special software
Example: CFW080040B2024EOA1
Note: (1) Not avaliable for 500-600V
101
1.3Variable Frequency Drives
www.pamensky.com
CFW 08 Plus - Table of Products200-240V - Single Phase
Electrical Data Mechanical Data Purchasing Data
Current
(A)
Braking
Transistor
Motor
(HP)Frame
Weight
(lb)
Degree of
Protection
Dimensions (in)
H x W x DWEG Part Number List Price
1.6 N 0.25 1 2.2 NEMA 1 5.95 x 2.95 x 5.16 CFW080016S2024EON1A1 $460
2.6 N 0.5 1 2.2 NEMA 1 5.95 x 2.95 x 5.16 CFW080026S2024EON1A1 465
4.0 N 1 1 2.2 NEMA 1 5.95 x 2.95 x 5.16 CFW080040S2024EON1A1 491
7.3 Y 2 2 4.4 NEMA 1 7.87 X 4.53 X 5.91 CFW080073B2024EON1A1 788
10 Y 3 2 4.4 NEMA 1 7.87 X 4.53 X 5.91 CFW080100B2024EON1A1 866
500-600V - Three Phase
Electrical Data Mechanical Data Purchasing Data
Current
(A)
Braking
Transistor
Motor
(HP)Frame
Weight
(lb)
Degree of
Protection
Dimensions (in)
H x W x DWEG Part Number List Price
1.7 Y 1 3 5.5 NEMA 1 7.99 x 5.63 x 6.50 CFW080017T5060EON1A1 $1,057
3 Y 2 3 5.5 NEMA 1 7.99 x 5.63 x 6.50 CFW080030T5060EON1A1 1,111
4.3 Y 3 3 5.5 NEMA 1 7.99 x 5.63 x 6.50 CFW080043T5060EON1A1 1,256
7 Y 5 3 5.5 NEMA 1 7.99 x 5.63 x 6.50 CFW080070T5060EON1A1 1,406
10 Y 7.5 3 5.5 NEMA 1 7.99 x 5.63 x 6.50 CFW080100T5060EON1A1 1,625
12 Y 10 3 5.5 NEMA 1 7.99 x 5.63 x 6.50 CFW080120T5060EON1A1 1,824
200-240V - Three Phase
Electrical Data Mechanical Data Purchasing Data
Current
(A)
Braking
Transistor
Motor
(HP)Frame
Weight
(lb)
Degree of
Protection
Dimensions (in)
H x W x DWEG Part Number List Price
1.6 N 0.25 1 2.2 NEMA 1 5.95 x 2.95 x 5.16 CFW080016B2024EON1A1 $535
2.6 N 0.5 1 2.2 NEMA 1 5.95 x 2.95 x 5.16 CFW080026B2024EON1A1 543
4.0 N 1 1 2.2 NEMA 1 5.95 x 2.95 x 5.16 CFW080040B2024EON1A1 568
7.0 N 2 1 2.2 NEMA 1 5.95 x 2.95 x 5.16 CFW080070T2024EON1A1 669
7.3 Y 2 2 4.4 NEMA 1 7.87 X 4.53 X 5.91 CFW080073B2024EON1A1 788
10 Y 3 2 4.4 NEMA 1 7.87 X 4.53 X 5.91 CFW080100B2024EON1A1 866
16 Y 5 2 4.4 NEMA 1 7.87 X 4.53 X 5.91 CFW080160T2024EON1A1 1,044
22 Y 7.5 3 5.5 NEMA 1 7.99 x 5.63 x 6.50 CFW080220T2024EON1A1 1,643
28 Y 10 4 13.2 NEMA 1 11.41 x 7.16 x 7.71 CFW080280T2024EON1A1 2,114
33 Y 12.5 4 13.2 NEMA 1 11.41 x 7.16 x 7.71 CFW080330T2024EON1A1 2,711
380-480V - Three Phase
Electrical Data Mechanical Data Purchasing Data
Current
(A)
Braking
Transistor
Motor
(HP)Frame
Weight
(lb)
Degree of
Protection
Dimensions (in)
H x W x DWEG Part Number List Price
1.0 N 0.33 1 2.2 NEMA 1 5.95 x 2.95 x 5.16 CFW080010T3848EON1A1 $662
1.6 N 0.75 1 2.2 NEMA 1 5.95 x 2.95 x 5.16 CFW080016T3848EON1A1 685
2.6 N 1 1 2.2 NEMA 1 5.95 x 2.95 x 5.16 CFW080026T3848EON1A1 705
2.7 Y 1 2 4.4 NEMA 1 7.87 X 4.53 X 5.91 CFW080027T3848EON1A1 767
4 N 2 1 2.2 NEMA 1 5.95 x 2.95 x 5.16 CFW080040T3848EON1A1 793
4.3 Y 2 2 4.4 NEMA 1 7.87 X 4.53 X 5.91 CFW080043T3848EON1A1 979
6.5 Y 3 2 4.4 NEMA 1 7.87 X 4.53 X 5.91 CFW080065T3848EON1A1 1,168
10 Y 5 2 4.4 NEMA 1 7.87 X 4.53 X 5.91 CFW080100T3848EON1A1 1,357
13 Y 7.5 3 5.5 NEMA 1 7.99 x 5.63 x 6.50 CFW080130T3848EON1A1 1,574
16 Y 10 3 5.5 NEMA 1 7.99 x 5.63 x 6.50 CFW080160T3848EON1A1 1,775
24 Y 15 4 13.2 NEMA 1 11.41 x 7.16 x 7.71 CFW080240T3848EON1A1 2,556
30 Y 20 4 13.2 NEMA 1 11.41 x 7.16 x 7.71 CFW080300T3848EON1A1 3,078
Notes: The maximum motor power ratings listed above are based on WEG 2 and 4 pole motors. For motors with different numbers of poles (ie. 6 and 8 poles), other voltages and/
or from other manufacturers, specify the VFD through the motor rated current.
101
Variable Frequency Drives1.4
www.pamensky.com
CFW 08 Wash - NEMA 4X (IP56) VFD
The frequency inverter CFW-08 Wash is an
inverter dedicated to applications that require a
higher protection degree. The Nema 4X
protection degree assures protection against
dust, dirt and directed water jets.
Standard Features - CFW 08
• V/Hz or Sensorless Vector Control
• NEMA 4X Enclosure
• Single and Three-phase input voltage
• 200-240V, 380-480V or 500-600V input
voltage, 50 - 60 Hz
• 150% current overload capacity
• 16 bit DSP controlled PWM output
• 2.5 / 5 / 10 / 15 kHz adjustable swiching
frequency
• Four isolated programmable digital inputs
• Two programmable relay outputs
• Two isolated programmable analog inputs
(with special function)
• One analog output
• Protective features: Over current, motor
overload, drive over temperature, output
phase-to-phase and phase-to-ground short
circuit, DC bus over and under voltage and
external fault
• Control features: Linear and “S” ramp
acceleration and deceleration, local/remote
control, DC braking, torque boost, motor slip
compensation, electronic pot, preset speeds,
adjustable V/Hz profi le, maximum and
minimum adjustable frequency limits, two skip
frequencies, adjustable output current limit,
JOG, ride-thru, fl ying start and PID regulator.
• Display readings: Motor speed, frequency,
voltage, current, last fault, heatsink
temperature and drive status
• Ambient: 32ºF (0ºC) to 104ºF (40ºC), 3300ft
(1000m) altitude, 90% humidity,
non-condensing
Recommended Environments
• NEMA 4X indoor environments
• NEMA 12 indoor environments
• IP56 environments
Optional Features
• Dynamic Braking capabilities available
• RS-232 or RS-485 Serial Interface
• Modbus Communication*
*Requires optional RS-232 or RS-485 Interface
Applications
• Pumps
• Fans
• Blowers
• Conveyors
• Rollout tables
• Agitators
• Mixers
101
1.5Variable Frequency Drives
www.pamensky.com
CFW 08 Wash - Table of Products
Notes: The maximum motor power ratings listed above are based on WEG 2 and 4 pole motors. For motors with different numbers of poles (ie. 6 and 8 poles), other voltages and/
or from other manufacturers, specify the VFD through the motor rated current.
200-240V - Single Phase
Electrical Data Mechanical Data Purchasing Data
Current
(A)
Braking
Transistor
Motor
(HP)Frame
Weight
(lb)
Degree of
Protection
Dimensions (in)
H x W x DWEG Part Number List Price
7.3 Y 2 A 11.2 NEMA 4X 10.43 x 6.50 x 8.50 CFW080073B2024EON4A1 $1,326
10 Y 3 A 11.2 NEMA 4X 10.43 x 6.50 x 8.50 CFW080100B2024EON4A1 1,456
200-240V - Three Phase
Electrical Data Mechanical Data Purchasing Data
Current
(A)
Braking
Transistor
Motor
(HP)Frame
Weight
(lb)
Degree of
Protection
Dimensions (in)
H x W x DWEG Part Number List Price
7.3 Y 2 A 11.2 NEMA 4X 10.43 x 6.50 x 8.50 CFW080073B2024EON4A1 $1,326
10 Y 3 A 11.2 NEMA 4X 10.43 x 6.50 x 8.50 CFW080100B2024EON4A1 1,456
16 Y 5 A 11.0 NEMA 4X 10.43 x 6.50 x 8.50 CFW080160T2024EON4A1 1,558
22 Y 7.5 B 15.4 NEMA 4X 13.40 x 8.47 x 8.50 CFW080220T2024EON4A1 2,090
28 Y 10 B 15.9 NEMA 4X 13.40 x 8.47 x 8.50 CFW080280T2024EON4A1 2,688
33 Y 12.5 B 15.9 NEMA 4X 13.40 x 8.47 x 8.50 CFW080330T2024EON4A1 3,296
500-600V - Three Phase
Electrical Data Mechanical Data Purchasing Data
Current
(A)
Braking
Transistor
Motor
(HP)Frame
Weight
(lb)
Degree of
Protection
Dimensions (in)
H x W x DWEG Part Number List Price
1.7 Y 1 B 13.9 NEMA 4X 13.40 x 8.47 x 8.50 CFW080017T5060EON4A1 $1,578
3 Y 2 B 15.4 NEMA 4X 13.40 x 8.47 x 8.50 CFW080030T5060EON4A1 1,818
4.3 Y 3 B 15.6 NEMA 4X 13.40 x 8.47 x 8.50 CFW080043T5060EON4A1 1,876
7 Y 5 B 15.6 NEMA 4X 13.40 x 8.47 x 8.50 CFW080070T5060EON4A1 2,098
10 Y 7.5 B 15.6 NEMA 4X 13.40 x 8.47 x 8.50 CFW080100T5060EON4A1 2,338
12 Y 10 B 15.6 NEMA 4X 13.40 x 8.47 x 8.50 CFW080120T5060EON4A1 2,624
380-480V - Three Phase
Electrical Data Mechanical Data Purchasing Data
Current
(A)
Braking
Transistor
Motor
(HP)Frame
Weight
(lb)
Degree of
Protection
Dimensions (in)
H x W x DWEG Part Number List Price
2.7 Y 1 A 10.1 NEMA 4X 10.43 x 6.50 x 8.50 CFW080027T3848EON4A1 $1,120
4.3 Y 2 A 11.5 NEMA 4X 10.43 x 6.50 x 8.50 CFW080043T3848EON4A1 1,428
6.5 Y 3 A 11.7 NEMA 4X 10.43 x 6.50 x 8.50 CFW080065T3848EON4A1 1,680
10 Y 5 A 11.7 NEMA 4X 10.43 x 6.50 x 8.50 CFW080100T3848EON4A1 1,800
13 Y 7.5 B 15.9 NEMA 4X 13.40 x 8.47 x 8.50 CFW080130T3848EON4A1 2,088
16 Y 10 B 15.9 NEMA 4X 13.40 x 8.47 x 8.50 CFW080160T3848EON4A1 2,354
24 Y 15 B 17.2 NEMA 4X 13.40 x 8.47 x 8.50 CFW080240T3848EON4A1 3,248
30 Y 20 B 17.4 NEMA 4X 13.40 x 8.47 x 8.50 CFW080300T3848EON4A1 4,250
101
Variable Frequency Drives1.6
www.pamensky.com
CFW 08 Plus - Accessories Keypads
Description Part Number List Price
NEMA4 Remote Keypad (requires CFW08-MIS-RS & cable) HMI-CFW08-RS $148
Remote Keypad Interface MIP-CFW08-RS 70
Keypad Cover TCL-CFW08 14
Keypad Cables
Description Part Number List Price
1m (3.3 ft.) Remote Keypad Cable CAB-RS-1 $23
2m (6.6 ft.) Remote Keypad Cable CAB-RS-2 31
3m (10 ft.) Remote Keypad Cable CAB-RS-3 42
5m (15 ft.) Remote Keypad Cable CAB-RS-5 52
7.5m (25 ft.) Remote Keypad Cable CAB-RS-7.5 62
10m (33 ft.) Remote Keypad Cable CAB-RS-10 73
Communication and Gland Kits
Description Part Number List Price
RS-232 Serial Comm. Module (mounted in place of keypad) KCS-CFW08 $112
PC Communication Kit (SUPERDRIVE) KSD-CFW08 144
Interface for RS-485 Communication KRS-485-CFW08 214
101
1.7Variable Frequency Drives
www.pamensky.com
CFW 08 Plus - Technical Data
Power Supply
Voltage
Single-Phase 200-240V: 200/220/230/240 V (+10% - 15%)
Three-Phase
200-240V: 200/220/230/240 V (+10% - 15%)
380-480V: 380/400/415/440/460/480 V (+10% - 15%)
500-600V: 525/575/600 (+10 - 15%)
Frequency 50 / 60 Hz +/- 2 Hz ( 48...62 Hz)
Cos * (Displacement Power Factor) > 0.98
Enclosure
Drive Standard NEMA 1 in sizes 3 and 4and IP 20 in sizes 1 and 2
HMI OptionalNEMA 12 Parallel, remote HMI (IP54) (HMI-CFW08-RS)
NEMA 12 Serial, remote HMI (IP54) (HMI-CFW08-RS)
Control
Power Supply Type Switching power supply
Control Method DSP (Digital Signal Processor), 16 bits, sinusoidal PWM (Space Vector Modulation)
Control TypeImposed voltage - linear V/Hz or quadratic
Sensorless vector control (WC: Voltage Vector Control)
Switching Frequency IGBT Transistors - Frequencies: 2.5 / 5.0 / 10 / 15 kHz
Frequency Range 0...300Hz
Fequency Resolution Analog Ref.: 0.1% of Fmax. And digital ref.: 0.01 Hz (f<100Hz); 0.1 Hz (f>100 Hz)
Accuracy (25º C = 10ºC) Analog Ref.: 0.5% and digital Ref.: 0.01%
Performance
Overload capacity 150% during 60 sec. Every 10 min (1.5 x Rated Current.)
Effi ciency >95% at full load
Speed control Regulation: 1% of the rated speed with slip compensation (in Sensorless Vector)
Control Inputs
Analog 2 isolated inputs 0..10, 0/4...20mA or - 10...+10V (Al1 e Al2)1
Digital4 Programmable isolated inputs - with NPN or PNP logic (Dl1...Dl4)
2 Isolated PTC inputs via AL1 and AL2
OutputsRelay (2) 2 Programmable outpluts, 1NO & 1NC
Analog (1) 1 Isolated analog output 0...10V, 0/4...20mA ( 8 bits )
CommunicationSerial Interface RS-232 or RS-485 (optional)
“Field Bus” Networks Unit for Profi Bus DP Communication, DeviceNet (optional) and ModBus RTU (optional)
Safety Protections
DC link overvoltage / undervoltage
Overtemperature
Output overcurrent
Motor overload ( i x t )
Hardware fault, external fault and serial communication error
Output phase to phase and phase to ground short circuit
Programming fault and self-tuning error
Human-Machine
Interface
(HMI)
Commands
On/Off , Parameter Setting ( Programming of special functions )
Frequency Increment / Decrement ( Speed )
JOG, Reversal of Direction of Rotation and Local /Remote Selection
Monitoring (Reading)
Motor Output Frequency ( Hz )
DC Link Voltage ( V )
Value proportional to the frequency ( Ex.:RPM )
Heat Sink Temperature
Motor Output Current ( A )
Motor Output Voltage ( V )
Error / Fault Messages
Load Torque
Environment
Temperature 0 ... 40 °C (up to 50 °C with output current derating 2% / °C)
Humidity 5 ... 90% non condensing
Altitude 0 ... 1000 m (up tp 4000 m with output current derating 10% / 1000 m)
Finishing Color Politherm 20 mt gray and Politherm 20 mt blue
Conformities
Electromagnetic Compatibility EMC Directive 89/336/EEC - Industrial Environment; EN 61800-3 (EMC - Emission and Immunity) - Special Request
Low Voltage LVD 73/23/EEC - Low Voltage Directive / UL 508C
IEC 146 Semiconductors convertors
UL 508 C Power conversion equipment
EN 50178 Electronic equipment for use in power installations
EN 61010 Safety requirements for electrical equipment for measurement, control and laboratory use
Certifi cations
UL (USA) and cUL (CANADA) Underwriters Laboratories Inc. / USA
CE (EUROPE) SGS / England
IRAM (ARGENTINA) Instituto Argentino de Normalización
C-Tick (AUSTRALIA) Australian Communications Authority
101
Variable Frequency Drives1.8
www.pamensky.com
CFW 09 - Variable Frequency Drive
The CFW 09‘s Vectrue Technology combines
V/F, Sensorless Vector and Closed Loop Vector
(with encoder) control techniques in one product.
Optimal Braking saves the need for the dynamic
braking resistor in some applications allowing a
more compact and economical solution.
Standard Features
• V/Hz or Sensorless Vector Control
• Self Tuning to motor parameters
• NEMA 1 Enclosure up to 200HP
• IP20 Enclosure from 250 to 500HP
• 200-240V, 380-480V or 500-600/690V input
voltage
• Single or Three-phase input voltage up to
3HP/230V
*Call 1 877 PAMENSKY for higher than 3HP
• 150% current overload capacity
• DC bus connections accessible
• Detachable Smart Keypad with dual display
and Copy Function
• 32 bit RISC microprocessor controlled PWM
output
• 1.25 / 2.5 / 5 / 10 kHz adjustable switching
frequency
• Six isolated programmable digital inputs
• Three programmable relay outputs (250Vac /
1A)
• Two isolated programmable analog inputs
• Two programmable analog outputs (0 - 10
Vdc)
• Protective features: Over current, motor
overload, drive over temperature, output
phase-to-phase and phase-to-ground short
circuit, DC bus over and under voltage,
power supply under voltage and phase loss
and external fault
Standard Features - cont.
• Control features: Linear and “S” ramp
acceleration and deceleration, local/remote
control, DC braking, torque boost, motor
slip compensation, electronic pot, preset
speeds, adjustable V/Hz profi le, maximum
and minimum adjustable motor speed limits,
three skip frequencies, adjustable output
current limit, JOG, ride-thru, fl ying start and
PID regulator
• Display readings: Motor speed, frequency,
voltage, current and torque, output power
(kW), last ten faults, drive status, digital and
analog I/O status, hours powered and hours
running
• Ambient: 32ºF (0ºC) to 104ºF (40ºC), 3300
ft (1000m) altitude, 90% humidity, non-
condensing
Optional Features
• Closed loop vector control
• Remote keypad with cable and mounting
frame
• RS-232 or RS-485 Serial Interface
• On/Off line PC programming with
SUPERDRIVE
• Fieldbus Comm: Profi bus DP, DeviceNet or
Modbus RTU, Ethernet TCP/IP
• Encoder buffered output
• Additional digital and analog I/O
• Dynamic Braking capabilities for most models
• PLC Cards
101
1.9Variable Frequency Drives
www.pamensky.com
CFW-09 - Part Number Specifi cation
1 2 3 4 5 6 7 8 9 13121110
S3H1DNA1DBSI--OP3848T0016 CFW09 Z
1. CFW-09 VSD
2. Output Rated Current for Constant Torque (CT) Sizing 220-230V 380-480V 500-600V 500-690V
0006 = 6.0A
0007 = 7.0A
0010 = 10A
0013 = 13A
0016 = 16A
0024 = 24A
0028 = 28A
0045 = 45A
0054 = 54A
0070 = 70A
0086 = 86A
0105 = 105A
0130 = 130A
0142 = 142A
0180 = 180A
0240 = 240A
0003 = 3.6A
0004 = 4.0A
0005 = 5.5A
0009 = 9.0A
0013 = 13A
0016 = 16A
0024 = 24A
0030 = 30A
0038 = 38A
0045 = 45A
0060 = 60A
0070 = 70A
0086 = 86A
0105 = 105A
0142 = 142A
0180 = 180A
0211 = 211A
0240 = 240A
0312 = 312A
0361 = 361A
0450 = 450A
0515 = 515A
0600 = 600A
0002 = 2.9A
0004 = 4.2A
0007 = 7.0A
0010 = 10A
0012 = 12A
0014 = 14A
0022 = 22A
0027 = 27A
0032 = 32A
0044 = 44A
0053 = 53A
0063 = 63A
0079 = 79A
0107 = 107A
0147 = 147A
0211 = 211A
0247 = 247A
0315 = 315A
0418 = 418A
0472 = 472A
0107 = 107A
0147 = 147A
0211 = 211A
0247 = 247A
0315 = 315A
0343 = 343A
0418 = 418A
0472 = 472A
* Selection Table for 2
3. Power Supply: T = Three-phase
4. Power Supply Voltage: 2223 = 220 ... 230 VAC
3848 = 380 ... 480 VAC
5060 = 500 ... 600 VAC
5069 = 500 ... 690 VAC
5. Language: P = Portuguese
E = English
G = German
S = Spanish
6. Product Version: S = Standard
O = With options
7. Enclosure: blank = Standard (see technical specifi cations table)
N4 = NEMA 4 / IP 56 (models up to 10HP)
8. HMI - Human Machine Interface:
blank = standard (with HMI of LED´S + LCD)
SI = Without HMI
IL = Optional only with LED HM
9. Dynamic Braking: blank = Standard
DB = With Built-in Dynamic Braking Transistor
RB = Regenative rectifying unit (models from 105A
at 220V, and from 86A at 380-480V)
10. Expansion Boards: blank = Standard
A1 = EBA.01-CFW09 optional
A2 = EBA.02-CFW09 optional
A3 = EBA.03-CFW09 optional
B1 = EBB.01-CFW09 optional
B2 = EBB.02-CFW09 optional
B3 = EBB.03-CFW09 optional
B4 = EBB.04-CFW09 optional
B5 = EBB.05-CFW09 optional
C1 = EBC1.01-CFW09 optional
C2 = EBC1.02-CFW09 optional
C3 = EBC1.03-CFW09 optional
E1 = Optional with EBE1.00 - CFW09
P1 = PLC1.01-CFW09 optional
P2 = PLC2.00-CFW09 optional
11. FieldBus Communications cards:
blank = Standard (not provided)
PD = KFB-PD optional (Profi bus DP)
DN = KFB-DN optional (Device Net)
DD = Optional with KFB – DD (Device Net Drive Profi le /
Special software)
EN = EtherNet / IP standard
12. Special Hardware: blank = not provided
H1...Hn = Special Hardware version-Optional
HD = Models from 105A at 220V, and from 86A at 380-480V are power supplied via DC link
HC/HV = The CFW09 VSDs mechanics from 2 to 8 have and inductor line for the DC link built into the product. To
request the VSD with the inductor in place just add the code “HC” (for drives operating on Variable Torque).
13. Special Software: blank = Standard Spftware Version
S1...Sn = Optional with version a special software
SF = Protocol Metasys N2
SC = Hoist functions
SN = Winder I with power calculation
SQ = Special version for Kit Device Net Drive Profi le
14. End of Part Number: Z
Example: CFW090013T2223ESZ
14
101
Variable Frequency Drives1.10
www.pamensky.com
CFW 09 - Table of Products
380-480V
Electrical Data Mechanical Data Purchasing Data
Current
(A)Built-In
Dynamic
Braking
Maximum Applicable Motor
FrameWeight
(lb)
Degree of
Protection
Dimensions
(in)
H x W x D
WEG Part NumberList
PriceConstant Torque Variable Torque
CT VT HP KW HP KW
3.6 Yes 2 1.5 2 1.5 1 8 NEMA 1 8.27 x 5.63 x 7.72 CFW090003T3848ESZ $1,646
4 Yes 2 1.5 2 1.5 1 8 NEMA 1 8.27 x 5.63 x 7.72 CFW090004T3848ESZ 1,685
5.5 Yes 3 2 3 2.2 1 8 NEMA 1 8.27 x 5.63 x 7.72 CFW090005T3848ESZ 1,744
9 Yes 5 4 5 4 1 8 NEMA 1 8.27 x 5.63 x 7.72 CFW090009T3848ESZ 1,884
13 Yes 7.5 6 7.5 5.5 2 13 NEMA 1 11.42 x 7.16 x 7.72 CFW090013T3848ESZ 1,980
16 Yes 10 8 10 7.5 2 13 NEMA 1 11.42 x 7.16 x 7.72 CFW090016T3848ESZ 2,464
24 Yes 15 11 15 11 2 13 NEMA 1 11.42 x 7.16 x 7.72 CFW090024T3848ESZ 2,654
30 36 Yes 20 15 25 18.5 3 42 NEMA 1 15.35 x 8.78 x 10.79 CFW090030T3848ESZ 3,780
38 45 Optional 25 18.5 30 22 4 50 NEMA 1 18.70 x 9.84 x 10.79 CFW090038T3848ESZ 4,502
45 54 Optional 30 22 40 30 4 50 NEMA 1 18.70 x 9.84 x 10.79 CFW090045T3848ESZ 5,628
60 70 Optional 40 30 50 37 5 90 NEMA 1 21.65 x 13.19 x 10.79 CFW090060T3848ESZ 6,976
70 86 Optional 50 37 60 45 5 90 NEMA 1 21.65 x 13.19 x 10.79 CFW090070T3848ESZ 7,430
86 105 Optional 60 45 75 55 6 121 NEMA 1 26.57 x 13.19 x 11.77 CFW090086T3848ESZ 9,110
105 130 Optional 75 55 100 75 6 121 NEMA 1 26.57 x 13.19 x 11.77 CFW090105T3848ESZ 9,956
142 174 Optional 100 75 125 90 7 154 NEMA 1 32.87 x 13.19 x 12.20 CFW090142T3848ESZ 11,862
180 External DB 150 110 150 110 8 221 NEMA 1 38.38 x 16.14 x 14.57 CFW090180T3848ESZ 18,778
211 External DB 150 110 150 110 8 221 NEMA 1 38.38 x 16.14 x 14.57 CFW090211T3848ESZ 21,410
240 External DB 200 150 200 150 8 221 NEMA 1 38.38 x 16.14 x 14.57 CFW090240T3848ESZ 22,280
312 External DB 250 185 250 185 9 476 IP20 39.37 x 27.56 x 19.33 CFW090312T3848ESZ 26,396
361 External DB 300 220 300 220 9 476 IP20 39.37 x 27.56 x 19.33 CFW090361T3848ESZ 27,584
450 External DB 350 260 350 260 10 571 IP20 46.65 x 27.56 x 19.33 CFW090450T3848ESZ 35,964
515 External DB 400 300 400 300 10 571 IP20 46.65 x 27.56 x 19.33 CFW090515T3848ESZ 41,636
600 External DB 500 370 500 370 10 571 IP20 46.65 x 27.56 x 19.33 CFW090600T3848ESZ 47,492
220-230V
Electrical Data Mechanical Data Purchasing Data
Current
(A)Built-In
Dynamic
Braking
Maximum Applicable Motor
FrameWeight
(lb)
Degree of
Protection
Dimensions
(in)
H x W x D
WEG Part NumberList
PriceConstant Torque Variable Torque
CT VT HP KW HP KW
6 Yes 1.5 1.1 1.5 1.1 1 8 NEMA 1 8.27 x 5.63 x 7.72 CFW090006T2223ESZ $1,468
7 Yes 2 1.5 2 1.5 1 8 NEMA 1 8.27 x 5.63 x 7.72 CFW090007T2223ESZ 1,486
10 Yes 3 2.2 3 2.2 1 8 NEMA 1 8.27 x 5.63 x 7.72 CFW090010T2223ESZ 1,563
13 Yes 3 2.2 3 2.2 1 8 NEMA 1 8.27 x 5.63 x 7.72 CFW090013T2223ESZ 1,605
16 Yes 5 3.7 5 3.7 2 13 NEMA 1 11.42 x 7.16 x 7.72 CFW090016T2223ESZ 1,731
24 Yes 7.5 5.5 5.5 5.5 2 13 NEMA 1 11.42 x 7.16 x 7.72 CFW090024T2223ESZ 2,274
28 Yes 10 7.5 10 7.5 2 13 NEMA 1 11.42 x 7.16 x 7.72 CFW090028T2223ESZ 2,517
45 Yes 15 11 15 11 3 42 NEMA 1 15.35 x 8.78 x 10.79 CFW090045T2223ESZ 3,837
54 68 Optional 20 15 25 18.5 4 50 NEMA 1 18.70 x 9.84 x 10.79 CFW090054T2223ESZ 5,339
70 86 Optional 25 18.5 30 22 5 90 NEMA 1 21.65 x 13.19 x 10.79 CFW090070T2223ESZ 7,716
86 105 Optional 30 22 40 30 5 90 NEMA 1 21.65 x 13.19 x 10.79 CFW090086T2223ESZ 8,124
105 130 Optional 40 30 50 37 6 121 NEMA 1 26.57 x 13.19 x 11.77 CFW090105T2223ESZ 9,788
130 150 Optional 50 37 50 37 6 121 NEMA 1 26.57 x 13.19 x 11.77 CFW090130T2223ESZ 10,488
142 174 Optional 50 37 60 45 7 154 NEMA 1 32.87 x 13.19 x 12.20 CFW090142T2223ESZ 12,178
180 External DB 60 45 60 45 8 221 NEMA 1 38.38 x 16.14 x 14.57 CFW090180T2223ESZ 16,863
240 External DB 75 55 75 55 8 221 NEMA 1 38.38 x 16.14 x 14.57 CFW090240T2223ESZ 24,057
Notes: The maximum motor power ratings listed above are based on WEG 2 and 4 pole motors. For motors with different numbers of poles (ie. 6 and 8 poles), other voltages and/
or from other manufacturers, specify the VFD through the motor rated current.
220-230V - With Optional Dynamic Braking
Electrical Data Mechanical Data Purchasing Data
Current
(A)Built-In
Dynamic
Braking
Maximum Applicable Motor
FrameWeight
(lb)
Degree of
Protection
Dimensions
(in)
H x W x D
WEG Part NumberList
PriceConstant Torque Variable Torque
CT VT HP KW HP KW
54 68 Yes 20 15 25 18.5 4 50 NEMA 1 18.70 x 9.84 x 10.79 CFW090054T2223EODBZ $6,377
70 86 Yes 25 18.5 30 22 5 90 NEMA 1 21.65 x 13.19 x 10.79 CFW090070T2223EODBZ 9,109
86 105 Yes 30 22 40 30 5 90 NEMA 1 21.65 x 13.19 x 10.79 CFW090086T2223EODBZ 9,589
105 130 Yes 40 30 50 37 6 121 NEMA 1 26.57 x 13.19 x 11.77 CFW090105T2223EODBZ 11,447
130 150 Yes 50 37 50 37 6 121 NEMA 1 26.57 x 13.19 x 11.77 CFW090130T2223EODBZ 12,266
142 174 Yes 50 37 60 45 7 154 NEMA 1 32.87 x 13.19 x 12.20 CFW090142T2223EODBZ 15,132
101
1.11Variable Frequency Drives
www.pamensky.com
CFW 09 - Table of Products380-480V - With Optional Dynamic Braking
Electrical Data Mechanical Data Purchasing Data
Current
(A)Built-In
Dynamic
Braking
Maximum Applicable Motor
FrameWeight
(lb)
Degree of
Protection
Dimensions
(in)
H x W x D
WEG Part NumberList
PriceConstant Torque Variable Torque
CT VT HP KW HP KW
38 45 Yes 25 19 30 22 4 50 NEMA 1 18.70 x 9.84 x 10.79 CFW090038T3848EODBZ $5,790
45 54 Yes 30 22 40 30 4 50 NEMA 1 18.70 x 9.84 x 10.79 CFW090045T3848EODBZ 7,884
60 70 Yes 40 30 50 37 5 90 NEMA 1 21.65 x 13.19 x 10.79 CFW090060T3848EODBZ 9,984
70 86 Yes 50 37 60 45 5 90 NEMA 1 21.65 x 13.19 x 10.79 CFW090070T3848EODBZ 10,832
86 105 Yes 60 45 75 55 6 121 NEMA 1 26.57 x 13.19 x 11.77 CFW090086T3848EODBZ 13,457
105 130 Yes 75 55 100 55 6 121 NEMA 1 26.57 x 13.19 x 11.77 CFW090105T3848EODBZ 15,678
142 174 Yes 100 75 125 90 7 154 NEMA 1 32.87 x 13.19 x 12.20 CFW090142T3848EODBZ 18,515
Notes: The maximum motor power ratings listed above are based on WEG 2 and 4 pole motors. For motors with different numbers of poles (ie. 6 and 8 poles), other voltages and/
or from other manufacturers, specify the VFD through the motor rated current.
500-600V - With Optional Dynamic Braking
Electrical Data Mechanical Data Purchasing Data
Current
(A)Built-In
Dynamic
Braking
Maximum Applicable Motor
FrameWeight
(lb)
Degree of
Protection
Dimensions
(in)
H x W x D
WEG Part NumberList
PriceConstant Torque Variable Torque
CT VT HP KW HP KW
22 27 Yes 20 15 25 18.5 4 50 NEMA 1 18.7 x 9.8 x 10.8 CFW090022T5060EODBZ $5,526
27 32 Yes 25 18.5 30 22 4 50 NEMA 1 18.7 x 9.8 x 10.8 CFW090027T5060EODBZ 6,516
32 32 Yes 30 22 30 22 4 50 NEMA 1 18.7 x 9.8 x 10.8 CFW090032T5060EODBZ 8,833
44 53 Yes 40 30 50 37 7 154 NEMA 1 32.9 x 13.2 x 11.8 CFW090044T5060EODBZ 11,490
53 63 Yes 50 37 60 45 7 154 NEMA 1 32.9 x 13.2 x 11.8 CFW090053T5060EODBZ 13,454
63 79 Yes 60 45 75 55 7 154 NEMA 1 32.9 x 13.2 x 11.8 CFW090063T5060EODBZ 16,120
79 99 Yes 75 55 100 75 7 154 NEMA 1 32.9 x 13.2 x 11.8 CFW090079T5060EODBZ 18,968
500-600V
Electrical Data Mechanical Data Purchasing Data
Current
(A)Built-In
Dynamic
Braking
Maximum Applicable Motor
FrameWeight
(lb)
Degree of
Protection
Dimensions
(in)
H x W x D
WEG Part NumberList
PriceConstant Torque Variable Torque
CT VT HP KW HP KW
2.9 4.2 Yes 2 1.5 3 2.2 2 13 NEMA 1 11.4 x 7.2 x 7.7 CFW090002T5060ESZ $1,742
4.2 7 Yes 3 2.2 5 4 2 13 NEMA 1 11.4 x 7.2 x 7.7 CFW090004T5060ESZ 1,801
7 10 Yes 5 3.7 7.5 5.5 2 13 NEMA 1 11.4 x 7.2 x 7.7 CFW090007T5060ESZ 2,305
10 12 Yes 7.5 5.5 10 7.5 2 13 NEMA 1 11.4 x 7.2 x 7.7 CFW090010T5060ESZ 2,413
12 14 Yes 10 7.5 15 9.2 2 13 NEMA 1 11.4 x 7.2 x 7.7 CFW090012T5060ESZ 2,935
14 14 Yes 15 9.2 15 9.2 2 13 NEMA 1 11.4 x 7.2 x 7.7 CFW090014T5060ESZ 3,271
22 27 Optional 20 15 25 18.5 4 50 NEMA 1 18.7 x 9.8 x 10.8 CFW090022T5060ESZ 4,194
27 32 Optional 25 18.5 30 22 4 50 NEMA 1 18.7 x 9.8 x 10.8 CFW090027T5060ESZ 4,928
32 32 Optional 30 22 30 22 4 50 NEMA 1 18.7 x 9.8 x 10.8 CFW090032T5060ESZ 6,708
44 53 Optional 40 30 50 37 7 154 NEMA 1 32.9 x 13.2 x 11.8 CFW090044T5060ESZ 8,941
53 63 Optional 50 37 60 45 7 154 NEMA 1 32.9 x 13.2 x 11.8 CFW090053T5060ESZ 10,550
63 79 Optional 60 45 75 55 7 154 NEMA 1 32.9 x 13.2 x 11.8 CFW090063T5060ESZ 12,558
79 99 Optional 75 55 100 75 7 154 NEMA 1 32.9 x 13.2 x 11.8 CFW090079T5060ESZ 14,928
500-690V
Electrical Data Mechanical Data Purchasing Data
Current
(A)Built-In
Dynamic
Braking
Maximum Applicable Motor
FrameWeight
(lb)
Degree of
Protection
Dimensions
(in)
H x W x D
WEG Part NumberList
PriceConstant Torque Variable Torque
CT VT HP KW HP KW
107 147 External DB 100 75 150 110 8E 253 NEMA 1 45.1 x 16.1 x 14.6 CFW090107T5069ESZ 18,119
147 196 External DB 150 110 200 150 8E 253 NEMA 1 45.1 x 16.1 x 14.6 CFW090147T5069ESZ 27,295
211 211 External DB 200 150 200 150 8E 253 NEMA 1 45.1 x 16.1 x 14.6 CFW090211T5069ESZ 36,995
247 315 External DB 250 185 300 220 10E 682 IP20 46.6 x 27.5 x 22.9 CFW090247T5069ESZ 39,018
315 343 External DB 300 220 350 250 10E 682 IP20 46.6 x 27.5 x 22.9 CFW090315T5069ESZ 42,264
343 418 External DB 350 250 400 300 10E 682 IP20 46.6 x 27.5 x 22.9 CFW090343T5069ESZ 56,796
418 472 External DB 400 300 500 370 10E 682 IP20 46.6 x 27.5 x 22.9 CFW090418T5069ESZ 61,225
472 555 External DB 500 370 600 450(370) 10E 682 IP20 46.6 x 27.5 x 22.9 CFW090472T5069ESZ 65,161
101
Variable Frequency Drives1.12
www.pamensky.com
CFW 09 Shark - Variable Frequency DriveCFW 09 Drives with a NEMA 4X (IP 56)
enclosure, designed for highly aggressive
environments including:
• Chemical industry
• Petrochemical
• Food industry
• Other applications requiring full protection
Standard Features
• V/Hz or Sensorless Vector Control
• Self Tuning to motor parameters
• NEMA 4X (IP56) Stainless Steel Enclosure
• 200-240V up to 5HP, 380-480V up to 10HP
• Single or Three-phase input voltage up to
3HP/230V
• 150% current overload capacity
• DC bus connections accessible
• Detachable Smart Keypad with dual display
and Copy Function
• 32 bit RISC microprocessor controlled PWM
output
• 1.25 / 2.5 / 5 / 10 kHz adjustable switching
frequency
• Six isolated programmable digital inputs
• Three programmable relay outputs
(250Vac/1A)
• Two isolated programmable analog inputs
• Two programmable analog outputs (0 - 10
Vdc)
• Protective features: Over current, motor
overload, drive over temperature, output
phase-to-phase and phase-to-ground short
circuit, DC bus over and under voltage,
power supply under voltage and phase loss
and external fault
Standard Features - cont.
• Control features: Linear and “S” amp
acceleration and deceleration, local/remote
control, DC braking, torque boost, motor
slip compensation, electronic pot, preset
speeds, adjustable V/Hz profi le, maximum
and minimum adjustable motor speed limits,
three skip frequencies, adjustable output
current limit, JOG, ride-thru, fl ying start and
PID regulator
• Display readings: Motor speed, frequency,
voltage, current and torque, output power
(kW), last four faults, drive status, digital and
analog I/O status, hours powered and hours
running
• Ambient: 32ºF (0ºC) to 104ºF (40ºC), 3300
ft (1000m) altitude, 90% humidity, non-
condensing
Optional Features
• Closed loop vector control
• RS-485 Serial Interface
• On/Off line PC programming with
SUPERDRIVE
• Fieldbus Comm: Profi bus DP, DeviceNet or
Modbus RTU (Requires optional RS-232 or
RS-485 Interface), Ethernet TCP/IP
• Encoder buffered output
• Additional digital and analog I/O
• Dynamic Braking capabilities for all models
101
1.13Variable Frequency Drives
www.pamensky.com
CFW 09 Shark - Table of Products
Notes: The maximum motor power ratings listed above are based on WEG 2 and 4 pole motors. For motors with different numbers of poles (ie. 6 and 8 poles), other voltages and/
or from other manufacturers, specify the VFD through the motor rated current.
220-230V
Electrical Data Mechanical Data Purchasing Data
Current
(A)Built-In
Dynamic
Braking
Maximum Applicable Motor
FrameWeight
(lb)
Degree of
Protection
Dimensions
(in)
H x W x D
WEG Part NumberList
PriceConstant Torque Variable Torque
CT VT HP KW HP KW
6 Yes 1.5 1.1 1.5 1.1 1 10 NEMA 4X 14.2 x 9.2 x 8.5 CFW090006T2223EON4Z $2,660
7 Yes 2 1.5 2 1.5 1 10 NEMA 4X 14.2 x 9.2 x 8.5 CFW090007T2223EON4Z 2,782
10 Yes 3 2.2 3 2.2 1 10 NEMA 4X 14.2 x 9.2 x 8.5 CFW090010T2223EON4Z 2,906
16 Yes 5 3.7 5 3.7 2 15 NEMA 4X 16.2 x 10.2 x 8.5 CFW090016T2223EON4Z 3,276
380-480V
Electrical Data Mechanical Data Purchasing Data
Current
(A)Built-In
Dynamic
Braking
Maximum Applicable Motor
FrameWeight
(lb)
Degree of
Protection
Dimensions
(in)
H x W x D
WEG Part NumberList
PriceConstant Torque Variable Torque
CT VT HP KW HP KW
3.6 Yes 2 1.5 2 1.5 1 10 NEMA 4X 14.2 x 9.2 x 8.5 CFW090003T3848EON4Z $2,782
4 Yes 2 1.5 2 1.5 1 10 NEMA 4X 14.2 x 9.2 x 8.5 CFW090004T3848EON4Z 2,854
5.5 Yes 3 2.2 3 2.2 1 10 NEMA 4X 14.2 x 9.2 x 8.5 CFW090005T3848EON4Z 2,980
9 Yes 5 3.7 5 3.7 2 15 NEMA 4X 16.2 x 10.2 x 8.5 CFW090009T3848EON4Z 3,114
13 Yes 7.5 5.5 7.5 5.5 2 15 NEMA 4X 16.2 x 10.2 x 8.5 CFW090013T3848EON4Z 3,300
16 Yes 10 7.5 10 7.5 2 15 NEMA 4X 16.2 x 10.2 x 8.5 CFW090016T3848EON4Z 3,980
101
Variable Frequency Drives1.14
www.pamensky.com
CFW 09 - Accessories
* Modbus RTU –requires optional RS-232 or RS-485 interface.
Dynamic Braking
Description Part Number List Price
External Dynamic Braking Module for 180A Model (16 X 9 X 10 NEMA 1 Enclosure) DBW01.0165D21801SZ $2,120
External Dynamic Braking Module for 211 & 240A Models (16 X 9 X 10 NEMA 1 Enclosure) DBW01.0240D21801SZ 2,590
External Dynamic Braking Module for 312, 361,450,515, & 600A Models (16 X 9 X 10 NEMA 1 Enclosure) DBW01.0300D21801SZ 3,159
External Dynamic Braking Module for 107,147,211,& 247A Models at 575V (16 X 9 X 10 NEMA 1 Enclosure) DBW02.0210D50691SZ 3,893
External Dynamic Braking Module for 315 & 343A Models at 575V (16 X 9 X 10 NEMA 1 Enclosure) DBW02.0300D50691SZ 5,133
External Dynamic Braking Module for 418 & 472 Amp Models at 575V (16 X 9 X 10 NEMA 1 Enclosure) DBW02.0380D50691SZ 6,363
Keypads
Description Part Number List Price
Standard Keypad with LED & LCD HMI-CFW09LCD $207
NEMA 4/IP56 Remote Keypad with LED & LCD HMI-CFW09LCD N4 268
Remote Keypad FRAME KIT KMR CFW09 91
Blank Keypad with Power & Error LED’s TCL CFW09 29
Caps
Description Part Number List Price
External DC Bus Cap Kit 1500uF (includes bleeder resistor, mounting bracket, & screws) CFW09CAP1500 $240
External DC Bus Cap Kit 4700uF (includes bleeder resistor, mounting bracket, & screws) CFW09CAP4700 280
Keypad Cables
Description Part Number List Price
1m (3.3 ft) Remote Keypad Cable CFW09HMI091 $31
2m (6.6 ft) Remote Keypad Cable CFW09HMI092 39
3m (10 ft) Remote Keypad Cable CFW09HMI093 50
5m (16 ft) Remote Keypad Cable CFW09HMI095 75
7.5m (25 ft) Remote Keypad Cable (Requires CFW09KMR09) CFW09HMI097 88
10m (33 ft) Remote Keypad Cable (Requires CFW09KMR09) CFW09HMI0910 108
Communication
Description Part Number List Price
SUPERDRIVE PC Communication Kit (includes software & hardware accessories) KSD CFW09 $161
RS-232 Serial Interface KCS CFW09 86
Profi bus DP Communication Kit KFB-PD 1,045
DeviceNet Communication Kit KFB DN 897
Ethernet IP Communication Kit (V3.70 or higher) KFB EN 1,562
101
1.15Variable Frequency Drives
www.pamensky.com
CFW 09 - AccessoriesI/O Expansion Boards
Description Part Number List Price
I/O Exp. Board A with Encoder Input, Encoder Output, RS-485 Serial Interface, I4 bit A/D, I4 bit D/A’s, Digital
Inputs and Outputs + Thermistor (PTC) InputEBA.01 CFW09 $1,414
I/O Exp. Board A with RS-485 Serial Interface, Digital Inputs and Outputs + Thermistor (PTC) Input EBA.02 CFW09 334
I/O Exp. Board A with I4 bit A/D, I4 bit D/A’s, Digital Inputs and Outputs + Thermistor (PTC) Input EBA.03 CFW09 654
I/O Exp. Board B with Encoder Input, Encoder Output, RS-485 Serial Interface, Isolated Analog Input, Isolated
Analog Outputs, Digital Inputs and Outputs + Thermistor (PTC) InputEBB.01-CFW09 1,192
I/O Exp. Board B with Encoder Input with internal Power Supply - 12VDC, Digital Inputs and Outputs + Thermistor
(PTC) InputEBB.02-CFW09 561
I/O Exp. Board B with Isolated Analog Input, Isolated Analog Outputs, Digital Inputs and Outputs + Thermistor
(PTC) InputEBB.03-CFW09 667
I/O Exp. Board B with Encoder Input, 5V Power Supply for Encoder, Buffered Outputs for Encoder Signals, RS-
485 Serial Port, 24V Digital Input, 2 X 24V DC Digital Outputs, 0…10V/4-20mA Analog Input, 2 X 4-20mA Analog
Outputs and PTC Thermistor Input
EBB.04-CFW09 1,487
I/O Exp. Board B with 2 X 4-20mA Analog Outputs EBB.05-CFW09 435
I/O Exp. Board C with Encoder Input, 5-15VDC External Power Supply EBC1.01 CFW09 194
EBC1.02 CFW09 504
I/O Exp. Board C with Encoder Input with internal Power Supply - 12VDC EBC1.03 CFW09 523
I/O Exp. Board E with RS-485 Serial Interface, Digital or Thermistor (PTC) Input EBE.01 CFW09 192
PLC/Motion Control Board PLC1.01 957
PLC/Motion Control Board with Communication Capabilities PLC2.00 1,148
Through Surface Mounting
Description Part Number List Price
Kit for Through Surface Mounting - Size 3 CFW09KMFM3 $16
Kit for Through Surface Mounting - Size 4 CFW09KMFM4 20
Kit for Through Surface Mounting - Size 5 CFW09KMFM5 22
Kit for Through Surface Mounting - Size 6 CFW09KMFM6 22
Kit for Through Surface Mounting - Size 7 CFW09KMFM7 22
Kit for Through Surface Mounting - Size 8 CFW09KMFM8 28
101
Variable Frequency Drives1.16
www.pamensky.com
CFW 09 - Technical Data
Power Supply
Voltage Three-phase:
220-230 V: 220/230 V (+10% -15%)
380-480 V: 380/400/415/440/460/480 V (+10% - 15%)
500-600 V: 525/575/600 V (+10% - 15%)
500-690 V: 525/575/600 (+10% - 15%) /690 V
Frequency 50 / 60 Hz +/- 2 Hz (48 ... 62 Hz)
Phase Unbalance Up to 3%
Cos (Displacement Power Factor) Greater Ihan 0.98 at full load
Enclosure
Degree of ProtectionNEMA 1/IP20 (sizes 1...8 and 8E), IP20 (sizes 9,10 and 10E)
NEMA 4X / IP56 (modules up to 10HP)
Finishing ColorPlastic Cover - Light Gray PANTONE 413 C (sizes 1 and 2)
Metallic Cover and Sides - Light Gray RAL 7032 (sizes 3 to 10)
Base - Dark Gray RAL 7022 (sizes 3 to 10)
Control
Power Supply Switched Mode Power Supply Fed from the DC Link
Microprocessor 32 bit RISC Technology
PWM TechniqueSVM Sine wave PWM (Space Vector Modulation)
Software Implemented Current fl ux and Speed Regulators (Full DigitaI)
Control Modes
V / F
Sensorless Vector (without encoder)
Vector with Encoder
Switching Frequency 1.25 / 2.5 / 5.0 / 10 kHz
Frequency Range0...1020 Hz for V / Hz Control
0...408 Hz for Vector Control
Overload Capacity150% for 60 seconds every 10 minutes
180% for 1 second every 10 minutes
Effi ciency Greater than 97% at full load
Performance
Speed Control
V / F Mode
Regulation (with Slip Compensation) : 1% 01 Motor Rated Speed
Resolution: 1 rpm (Keypad Reference)
Speed Regulation Range: 1: 20
Sensorless
Vector Mode
Regulation: 0.5% of Motor Rated Speed
Resolution: 1 rpm (Keypad Reference)
Speed Regulation Range: 1:100
Encoder Vector
Mode
Regulation with:
10 bit Analogy Reference: +1- 0.1% 01 Motor Rated Speed
14 bit Analogy Reference: +- 0.01% 01 Motor Rated Speed
Digital Reference (Ex: Keypad): + / - 0.01 % of Motor Rated Speed
Speed Regulation Range: Down to 0 rpm
Torque Control Vector ModesRegulation: + - 10% of Motor Rated Torque
Range: O ... 150% 01 Motor Rated Torque
Control Inputs
Analog
2 Programmable Differential Input (10 bit) : 0...10 V 0...20 mA or 4...20 mA
1 Programmable Bipolar Input (14 bit): -10 ... + 10 V 0...20 mA or 4...20 mA
1 Programmable Isolated Input (10 bit) : O ... 10 V 0...20 mA or 4...20 mA
Digital
6 Programmable Isolated Input: 24 Vdc
1 Programmable Isolated Input: 24 Vdc
1 Programmable Isolated Input: 24 Vdc (for Motor PTC Thermistor)
Encorder 1 Isolated Differencial Encoder Signals Output: 5 ...15 Vdc External Power Supply
CommunicationSerial
RS-232 with KCS-GFW09 Kn - RS-485 Isolated with EBA or EBB Board
Johnson Contols-N2 (optional)
Fieldbus Modbus RTU Standard, Profi bus DP, DeviceNet, EtherNet / IP, DeviceNet Drive Profi le with KFB kits.
Safety Protections
DC Link Under Voltage Output Short Circuit
DC Link Over Voltage Output Ground Fault
Drive Over Temperature External Fault
Motor Over Temperature SeIf -diagnosis Fault
Output Over Current Programming Error
Motor Overload (i x t) Serial Communication Fault
Dynamic Braking Resistor Overload Motor or Encoder Connection Fault
CPU / EPROM Error ( watchdog) Power Supply Ohase Fault (30 A and above models)
Encoder Fault Keypad Connection Fault
Ambient
Temperature 0ºC (32ºF)...40ºC (104ºF), up to 50ºC (122ºF) with 2% / ºC (1,1% / ºF) output current derating
Humidity 5...90% Non Condensing
Altitude 0...1000m (3300ft), up to 4000m (13100ft) with 10% / 1000m (3% / 1000ft) output current derating
Conformities
EMC Directive 89 / 336 / EEC - EM 61800-3 Electromagnetie Compatible - Industrial Environment - EMC - Emission and Immunity
LVD 73 / 23 / EEC Low Voltage Directive
IEC 146 Semiconductor drive
UL 508C Power Conversion Enuinment
EN 50178 Electronic Equipment for Use in Power Installations
EN 61010 Safety Requirements for Electrical Equipament for Measurement Control and laboratory Use
Certifi cations
UL (USA) and cUL (CANADA) Underwriters laboratories Ine. USA
CE (EUROPE) Phoenix Test-Lab GmbH – Germany (Competent Body)
IRAM (ARGENTINA) Instituto Argentino de Normalización
C-Tiek (AUSTRALIA) 2250/1132383 Australian Communications Aulhority
101
1.17Variable Frequency Drives
www.pamensky.com
CFW 09 - Technical Data
Keypad
Programming General Drive Functions Programming
Controls Start/Stop , Increase/Decrease Speed, JOG, FWD/REV and Local/Remote
Monitoring
Speed Reference (rpm) Oulput Current (A)
Motor Speed (rpm) Oulput Voltage (Vac)
Speed Proportional Value (Ex: ft/min) Drive Status
Output Frequency (Hz) Digital Inputs Status
DC Link Voftage (Vdc) Transistor Outputs Status
Motor Torque (%) Relay Outputs Status
Outout Power (kW) Analog Inputs Value
Hours Powered Up (h) Four Last Faults
Hours Enabled (h) Fault Messages
Control Features Standard
Keypad wilh LCD + LED displays (HMI-CFW09-LCD)
Password to protect drive programming
LCD display language selection: English, Spanish and Portuguese
Control mode selection (via parameter}: V / F. Sensorless Vector or Vector with Encoder
Fault auto-diagnosis and auto-reset
Parameters reset to factory or user default
Drive Self-tuning to motor and load (Vector Modes)
Specifi c unit indication ( Ex: l/s, t/h, %, etc. )
Motor slip compensation (V / F Mode)
Manual and automatic Torque Boost (V / F Mode)
Adjustable V / F Curve (V / F Mode)
Minimum and maximum speed limits
Output current limit
Adjustable motor overload protection
Digital gain and offset adjustments for the analog inputs
Digital gain adjustment for the analog outputs
JOG function
JOG + I JOG - Function (momentary speed increase/decrease)
COPY Function (Drive to Keypad or Keypad to Drive)
Comparison functions for lhe digital outputs: N* > Nx; N > Nx; N < Nx; N = O; N = N*; Is > Ix ; Is < Ix; T > Tx and T < Tx
Where: N = Motor speed; N* = Speed reference; Is = Output Current and T = Motor torque
Linear and S independent acceleration and deceleration ramps, two sets of ramps
DC Braking
Optimal Braking (Vector Modes)
Built-in dynamic braking transistor – Models up to 45A/220-230V and up to 30A/380-480V and up to 14A/500-600V
Multi-speed function (up to 8 preset speeds)
Speed Profi ling function
Hour meter and Wattrneter
Overlapping PID Regulator (for automatic control of level, pressure, fl ow, etc. )
FWD I REV selection
Local I Remate operation selection
Flying Start function (restart with the motor spinning)
Skip Speed (critical speed rejection)
Ride-Through (operation during momentary power loss)
Built-in dynamic braking transistor:
Models: 6 ... 45 A / 220 - 230 V and 36 ... 30 A / 380 - 480 V
FieldBus communication: Modbus RTU built-in
101
Variable Frequency Drives1.18
www.pamensky.com
CFW 10 - Variable Frequency Drive
Standard Features
• V/Hz control
• IP20 fi nger safe enclosure
• Single Phase 110-127V input voltage up to
1 HP
• Single Phase 200–240V input voltage up to
3 HP
• 150% current overload capacity
• DSP controlled PWM output
• 2.5-15 kHz adjustable switching frequency
• Four isolated programmable digital inputs
• Programmable relay output
• One isolated programmable analog input
• Diagnostic features: Over current, motor
overload, drive over temperature, output short
circuit, DC bus over and under voltage and
external fault
• Control features: Linear and S-Ramp
acceleration and deceleration, local / remote
control, DC braking, torque boost, motor slip
compensation, electronic pot, preset speeds,
minimum and maximum adjustable frequency
limits, adjustable output current limit, JOG
• Display readings: Motor speed, frequency,
voltage, current, last 3 faults, heatsink
temperature and drive status, DC link voltage
• Ambient: 122°F (50°C), 3300 ft (1000 m)
altitude, 90% humidity, non-condensing
Applications
• Pumps
• Fans/Blowers
• Blowers
• Conveyors
• Rollout tables
The WEG CFW 10 VFD provides a robust drive
solution in a compact, easily mounted package.
A simplifi ed keypad and bright LED readout,
complete diagnostics and fully programmable
I/O makes the CFW 10 an ideal control device
when requiring an economical drive solution for
small motors.
101
1.19Variable Frequency Drives
www.pamensky.com
CFW-10 - Part Number Specifi cation
1 2 3 4 5 6 7 8 9 1110
Z-- -- -- --OE2024S0040CFW10
1. CFW-10 Variable Frequency Drive
2. Output Rated Current 110-127V 200-240V
0016 = 1.6 A
0026 = 2.6 A
0040 = 4.0 A
0016 = 1.6A
0026 = 2.6A
0040 = 4.0A
0073 = 7.3A
0100 = 10.0A
* Selection Table for 2
3. Power Supply: S = single-phase
4. Power Supply Voltage: 1112 = 110-127 V (Single-phase only)
2024 = 200-240 V
5. Language: P = Portuguese
E = English
S = Spanish
6. Product Version: S = Standard
O = With options
7. Control Card: blank = Standard
CL = clean
PL = plus (with potentiometer)
8. EMC Built-in Filter: blank = (not avaliable)
FA = with EMC fi lter (class A) –
Only for single-phase models (200-240V) models
9. Special Hardware: Blank = not provided
Hx = special hardware in version X
CP = Cold Plate heatsink version
10. Special Software: Blank = not provided
Sx = special software in version X
11. End of Part Number: Z
Example: CFW100040S2024ESZ
101
Variable Frequency Drives1.20
www.pamensky.com
CFW 10 - Table of Products
CFW 10 - Technical Data
110-127V - Single Phase
Electrical Data Mechanical Data Purchasing Data
Current
(A)
Motor
(HP)Frame
Weight
(lb)Degree of Protection
Dimensions
H x W xD (in)WEG Part Number List Price
1.6 0.25 1 2.0 IP20 5.20 x 3.74 x 4.76 CFW100016S1112ESZ $401
2.6 0.5 1 2.0 IP20 5.20 x 3.74 x 4.76 CFW100026S1112ESZ 432
4.0 1 2 3.3 IP20 6.34 x 4.53 x 4.80 CFW100040S1112ESZ 656
200-240V - Single Phase
Electrical Data Mechanical Data Purchasing Data
Current
(A)
Motor
(HP)Frame
Weight
(lb)Degree of Protection
Dimensions
(in)WEG Part Number List Price
1.6 0.25 1 2.0 IP20 5.20 x 3.74 x 4.76 CFW100016S2024ESZ $349
2.6 0.5 1 2.0 IP20 5.20 x 3.74 x 4.76 CFW100026S2024ESZ 375
4 1 1 2.0 IP20 5.20 x 3.74 x 4.76 CFW100040S2024ESZ 385
7.3 2 2 3.3 IP20 6.34 x 4.53 x 4.80 CFW100073S2024ESZ 571
10 3 3 4.0 IP20 7.46 x 4.53 x 4.80 CFW100100S2024ESZ 680
Power Supply
VoltageSingle phase 110…127V (+10%, -15%)
Single phase 200…240V (+10%, -15%)
Frequency 50 / 60Hz +/- 2Hz
Cos (Displacement Power Factor) Greater than 0.98
EnclosureDegree of Protection IP20
Control Mode Linear or Quadratic V/Hz
Control
Power Output 16 bit DSP
Sinusoidal PWM (Space Vector
Modulation)
Switching Frequency IGBT Transistors 2.5, 5, 10 or 15kHz
Frequency Range 2.5…15kHz Switching Frequency
Overload Capacity 0-300 Hz
Control Inputs
4 programmable isolated digital
outputs150% during 60 sec. every 10 min.
1 programmable differential analog input: 0-10V, 0-20mA or 4-20mA
Control Ouput 1 programmable realy outputs, one reversing (Form C) contact: 250V / 0.5A
Safety Protections
Motor over current DC link over voltage
Motor overload DC link under voltage
output phase-to-phase short circuit Drive over temperature
output phase-to-ground short circuit external fault
programming error
Ambient
Temperature 0…104F (40ºC), up to 122ºF (50ºC) with 2% / 1.8ºF (1ºC) output current derating
Humidity 5…90% Non Condensing
Altitude0…3300 ft (1000m), up to 13,200 ft (4000m) with 10% / 3300ft (1000m) output
current derating
Conformities
EMC Directive 89 / 336 / EEC Electromagnetic compatibility – Industrial Environment EMC – Emission and Immunity
ENC61800-3
LVD 73/23/EEC Low Voltage Directive
UL 508 C Power Conversion Equipment
Special Functions
Linear and “S” ramp accel and decel, local/remote control, FWD/REV selection, DC braking, manual and auto torque
boost, motor slip compensation, electronic pot, two skip frequencies, maximum and minimum adjustable frequency limits,
adjustable output current limit, 8 present speeds and JOG.
Keypad
3 digit display, 2 indication LEDs and 4 keys
Readouts for: output freqency (Hz), output current (A), output voltage (V), value proportional to frequency (Ex: RPM),
heatsink temperature, fault and status messages.
Mounting Surface with screws
Notes: The maximum motor power ratings listed above are based on WEG 2 and 4 pole motors. For motors with different numbers of poles (ie. 6 and 8 poles), other voltages and/
or from other manufacturers, specify the VFD through the motor rated current.
101
1.21Variable Frequency Drives
www.pamensky.com
CFW 11 - System Variable Frequency Drive
Standard Features
• Plug and play philosophy (connect and
use) enables quick and easy installation of
accessories and options
• USB for computer connection for using
SUPERDRIVE G2 programming and
monitoring software
• Human-Machine Interface (HMI) with backlit
graphic display and soft-keys, greatly
facilitates inverter programming and operation
• DC link inductors (symetrically connected
to positive and negative DC link terminals)
enable compliance with IEC61000-3-12
standard requirements regarding harmonics,
(no need for external line reactance)
• Intelligent thermal management enables full
protection of IGBTs, monitoring of heatsink
and internal air temperature
• Automatic control of the heatsink fan with
speed sensor (additional protection) and
easily detachable from the unit for cleaning
and maintenance
• Normal Duty and Heavy Duty ratings to adapt
optimally to all kinds of loads
• Protection with failure and alarm warnings
• Motor overload protection in compliance with
IEC 60947-4-2/UL 508 C
• On board memory allows user to create
functions without the need to use an external
PLC (soft-PLC via IEC61131-3 programming
software)
Standard Features - cont.
• Guided start-up simplifi es initial user
programming.
• Real time clock
• TRACE / SCOPE function to assist with
the start-up and system diagnostics via
SUPERDRIVE G2
Optional Features
• Interface for incremental encoder 5 to 12Vdc
• Interface for RS-485 serial communication
(modbus)
• Interface for RS-232C serial communication
• CAN interface
• Profi bus DP interface
• PLC functions; IEC programming
• Devicenet 4 interface
• Ethernet IP interface
• Blind cover for slot HMI
• Frame for remote HMI
• Conduit kit
• Optimal Braking®
• IP20
Factory Options
• Safety Stop
• RFI Filter
• 24 VDC power input option for control section
The WEG CFW 11 inverters use Plug and Play technology
to recognize and confi gure accessories providing easy and
safe operation. Programming is simpler using the standard
USB port. Soft PLC lets the user create functions without
the need for an external PLC.
ency Driv
101
Variable Frequency Drives1.22
www.pamensky.com
CFW-11 - Part Number Specifi cation
1 32 654 7 8 9 13121110
-- -- -- -- -- ------S4T- 0016 CFW11 Z
1. CFW-11 Variable Frequency Drive
2. Type of Construction: Blank = Inverter in cabinet
M = Inverter with modular construction to meet elevated powers, “modular drive” line
3. Output Rated Current 220-240V 380-480V 500-690V
0007 = 7 A
0010 = 10 A
0013 = 13 A
0016 = 16 A
0024 = 24 A
0028 = 28 A
0033 = 33 A
0045 = 45 A
0054 = 54 A
0070 = 70 A
0086 = 86 A
0105 = 105 A
0142 =142 A
0180 = 180 A
0211 = 211 A
0003 = 3 A
0005 = 5 A
0007 = 7 A
0010 = 10 A
0013 = 13 A
0017 = 17 A
0024 = 24 A
0031 = 31 A
0038 = 38 A
0045 = 45 A
0058 = 58 A
0070 = 70 A
0088 = 88 A
0105 = 105 A
0142 = 142 A
0180 = 180 A
0211 = 211 A
0242 = 242 A
0312 = 312 A
0370 = 370 A
0477 = 477 A
0515 = 515 A
0601 = 601 A
0720 = 720 A
0002 = 2.9 A
0004 = 4.2 A
0007 = 7 A
0010 = 10 A
0012 = 12 A
0017 = 17 A
0022 = 22 A
0027 = 27 A
0032 = 32 A
0044 = 44 A
0053 = 53 A
0063 = 63 A
0080 = 80 A
0107 = 107 A
0125 = 125 A
0150 = 150 A
0170 = 170 A
0216 = 216 A
0289 = 289 A
0315 = 315 A
0365 = 365 A
0435 = 435 A
* Selection Table for 2
4. Power Supply: S = single-phase
T = three-phase
B = single-phase or three-phase
5. Power Supply Voltage: 2 = 200-240 V
4 = 380-480 V
5 = 500-600 V
6 = 660-690 V
6. Product Version: S = Standard
O = With options
7. Enclosure: Blank = factory standard
Sizes A, B and C: IP21
D: Nema 1/IP20
N1 = Nema 1
21 = IP21
8. HMI - Human Machine Interface:
blank = standard (with HMI of LED´S + LCD)
IC = Without HMI
9. Braking: blank = standard
(Sizes A, B, C and D: built-in braking IGBT)
F = Standard product including Brake Chopper
DB = Dynamic Braking (Factory Option)
10. RFI Filter (Not Applicable to CFW-11M Models):
Blank = standard
FA = Category C3 internal RFI fi lter
11. Safety Stop: Blank = standard (without safety stop function)
Y = with safety stop function according to EN-954-1 category 3
12. External Electronic Supply 24 Vdc (not applicable to models CFW-11M):
Blank = factory standard:
model CFW-11 (without) ; model CFW-11M (with)
12. Special Hardware: Blank = factory standard (without)
H1 = special hardware nr. 1
13. Special Software: Blank = factory standard (without)
S1 = special software nr. 1
14. End of Part Number: Z
Example: CFW110016T4SZ
14 15
4 Vdc icable to
CFW-11M):
model CFW-11 (without) ; model CFW-11M (with)
Hardware: Blank = factory standard (without)
H1 = special hardware nr. 1
Software: Blank = factory standard (without)
S1 = special software nr. 1
art Number: Z
: CFW110016T4SZ
101
1.23Variable Frequency Drives
www.pamensky.com
CFW 11 - Table of Products
Notes: The maximum motor power ratings listed above are based on WEG 2 and 4 pole motors. For motors with different numbers of poles (ie. 6 and 8 poles), other voltages and/
or from other manufacturers, specify the VFD through the motor rated current.
200-240V - Single Phase
Electrical Data Mechanical Data Purchasing Data
Current
(A)Built-In
Dynamic
Braking
Maximum Applicable Motor
FrameWeight
(lb)
Degree of
Protection
Dimensions
(in)
H x W x D
Part NumberList
PriceND* HD*
ND* HD* HP HP
6 5 Yes 1.5 1 A 12.6 NEMA 1 12.04 x 5.71 x 8.94 CFW110006B2ON1Z $1,936
7 7 Yes 2 2 A 12.6 NEMA 1 12.04 x 5.71 x 8.94 CFW110007B2ON1Z 1,996
10 10 Yes 3 3 A 13.4 NEMA 1 12.04 x 5.71 x 8.94 CFW110010S2ON1Z 2,117
200-240V - Three Phase
Electrical Data Mechanical Data Purchasing Data
Current
(A)Built-In
Dynamic
Braking
Maximum Applicable Motor
FrameWeight
(lb)
Degree of
Protection
Dimensions
(in)
H x W x D
Part NumberList
PriceND* HD*
ND* HD* HP HP
6 5 Yes 1.5 1 A 12.6 NEMA 1 12.04 x 5.71 x 8.94 CFW110006B2ON1Z $1,936
7 7 Yes 2 2 A 12.6 NEMA 1 12.04 x 5.71 x 8.94 CFW110007B2ON1Z 1,996
7 5.5 Yes 2 1.5 A 12.6 NEMA 1 12.04 x 5.71 x 8.94 CFW110007T2ON1Z 1,851
10 8 Yes 3 2 A 12.6 NEMA 1 12.04 x 5.71 x 8.94 CFW110010T2ON1Z 1,967
13 11 Yes 4 3 A 13.4 NEMA 1 12.04 x 5.71 x 8.94 CFW110013T2ON1Z 2,047
16 13 Yes 5 4 A 13.9 NEMA 1 12.04 x 5.71 x 8.94 CFW110016T2ON1Z 2,203
24 20 Yes 7.5 6 B 20.1 NEMA 1 13.82 x 7.45 x 8.94 CFW110024T2ON1Z 2,740
28 24 Yes 10 7.5 B 20.1 NEMA 1 13.82 x 7.45 x 8.94 CFW110028T2ON1Z 2,794
33.5 28 Yes 12.5 10 B 20.1 NEMA 1 13.82 x 7.45 x 8.94 CFW110033T2ON1Z 3,182
45 36 Yes 15 12.5 C 41.7 NEMA 1 17.64 x 8.66 x 11.51 CFW110045T2ON1Z 3,583
54 45 Yes 20 15 C 41.7 NEMA 1 17.64 x 8.66 x 11.51 CFW110054T2ON1Z 4,410
70 56 Yes 25 20 C 41.7 NEMA 1 17.64 x 8.66 x 11.51 CFW110070T2ON1Z 5,139
86 70 Yes 30 25 D 71.7 NEMA 1 19.82 x 11.81 x 12.00 CFW110086T2SZ 6,514
105 86 Yes 40 30 D 71.7 NEMA 1 19.82 x 11.81 x 12.00 CFW110105T2SZ 8,369
142 115 No 50 40 E 143.3 NEMA 1 26.60 x 13.20 x 14.10 CFW110142T2ON1Z 12,249
180 142 No 60 50 E 143.3 NEMA 1 26.60 x 13.20 x 14.10 CFW110180T2ON1Z 17,051
211 180 No 75 60 E 143.3 NEMA 1 26.60 x 13.20 x 14.10 CFW110211T2ON1Z 21,840
* ND - Normal Duty
• 110% during 60 seconds every 10 minutes
• 150% during 3 seconds every 10 minutes
* HD - Heavy Duty
• 150% during 60 seconds every 10 minutes
• 200% during 3 seconds every 10 minutes
380-480V - Three Phase
Electrical Data Mechanical Data Purchasing Data
Current
(A)Built-In
Dynamic
Braking
Maximum Applicable Motor
FrameWeight
(lb)
Degree of
Protection
Dimensions
(in)
H x W x D
Part NumberList
PriceND* HD*
ND* HD* HP HP
3.6 3.6 Yes 2 2 A 5.7 NEMA 1 12.04 x 5.71 x 8.94 CFW110003T4ON1Z $1,903
5 5 Yes 3 3 A 5.9 NEMA 1 12.04 x 5.71 x 8.94 CFW110005T4ON1Z 2,024
7 5.5 Yes 4 3 A 5.9 NEMA 1 12.04 x 5.71 x 8.94 CFW110007T4ON1Z 2,091
10 10 Yes 6 6 A 6.1 NEMA 1 12.04 x 5.71 x 8.94 CFW110010T4ON1Z 2,161
13.5 11 Yes 7.5 6 A 6.3 NEMA 1 12.04 x 5.71 x 8.94 CFW110013T4ON1Z 2,265
17 13.5 Yes 10 7.5 B 9.1 NEMA 1 13.82 x 7.45 x 8.94 CFW110017T4ON1Z 2,745
24 19 Yes 15 12.5 B 9.7 NEMA 1 13.82 x 7.45 x 8.94 CFW110024T4ON1Z 3,324
31 25 Yes 20 15 B 10.4 NEMA 1 13.82 x 7.45 x 8.94 CFW110031T4ON1Z 4,120
38 33 Yes 25 20 C 18.9 NEMA 1 17.64 x 8.66 x 11.51 CFW110038T4ON1Z 4,542
45 38 Yes 30 25 C 18.9 NEMA 1 17.64 x 8.66 x 11.51 CFW110045T4ON1Z 5,725
58.5 47 Yes 40 30 C 18.9 NEMA 1 17.64 x 8.66 x 11.51 CFW110058T4ON1Z 7,093
70.5 61 Yes 50 40 D 32.5 NEMA 1 19.82 x 11.81 x 12.00 CFW110070T4SZ 7,723
88 73 Yes 60 50 D 32.5 NEMA 1 19.82 x 11.81 x 12.00 CFW110088T4SZ 9,302
105 88 No 75 60 E 143.3 NEMA 1 26.60 x 13.20 x 14.10 CFW110105T4ON1Z 10,388
142 115 No 100 75 E 143.3 NEMA 1 26.60 x 13.20 x 14.10 CFW110142T4ON1Z 12,218
180 142 No 150 100 E 143.3 NEMA 1 26.60 x 13.20 x 14.10 CFW110180T4ON1Z 17,914
211 180 No 150 150 E 143.3 NEMA 1 26.60 x 13.20 x 14.10 CFW110211T4ON1Z 20,837
242 211 No 200 150 F 308.6 IP20 48.58 x 16.93 x 14.17 CFW110242T4SZ 21,719
312 242 No 250 200 F 308.6 IP20 48.58 x 16.93 x 14.17 CFW110312T4SZ 25,735
370 312 No 300 250 F 308.6 IP20 48.58 x 16.93 x 14.17 CFW110370T4SZ 26,893
477 370 No 400 300 F 308.6 IP20 48.58 x 16.93 x 14.17 CFW110477T4SZ 33,217
515 477 No 450 400 G 474.0 IP20 49.76 x 21.06 x 16.77 CFW110515T4SZ 38,456
601 515 No 500 450 G 474.0 IP20 49.76 x 21.06 x 16.77 CFW110601T4SZ 43,866
720 560 No 600 450 G 474.0 IP20 49.76 x 21.06 x 16.77 CFW110720T4SZ 48,740
101
Variable Frequency Drives1.24
www.pamensky.com
CFW 11 - Table of Products500-600V - Three Phase
Electrical Data Mechanical Data Purchasing Data
Current
(A)Built-In
Dynamic
Braking
Maximum Applicable Motor
FrameWeight
(lb)
Degree of
Protection
Dimensions
(in)
H x W x D
Part NumberList
PriceND* HD*
ND* HD* HP HP
2.9 2.7 Standard 2 2 B 20.1 NEMA 1 12.4 x 7.5 x 8.9 CFW110002T5ON1NFZ $2,818
4.2 3.8 Standard 3 3 B 20.1 NEMA 1 12.4 x 7.5 x 8.9 CFW110004T5ON1NFZ 2,895
7.0 6.5 Standard 5 5 B 20.1 NEMA 1 12.4 x 7.5 x 8.9 CFW110007T5ON1NFZ 3,074
10 9.0 Standard 7.5 7.5 B 20.1 NEMA 1 12.4 x 7.5 x 8.9 CFW110010T5ON1NFZ 3,128
12 10 Standard 10 10 B 20.1 NEMA 1 12.4 x 7.5 x 8.9 CFW110012T5ON1NFZ 3,283
17 17 Standard 15 15 B 20.1 NEMA 1 12.4 x 7.5 x 8.9 CFW110017T5ON1NFZ 3,412
500-690V - Three Phase
Electrical Data Mechanical Data Purchasing Data
Current
(A)Built-In
Dynamic
Braking
Maximum Applicable Motor
FrameWeight
(lb)
Degree of
Protection
Dimensions
(in)
H x W x D
Part NumberList
PriceND* HD*
ND* HD* HP HP
22 19 Optional 20 15 D 75 NEMA 1 21.7 x 11.8 x 12.0 CFW110022T6ONBZ $5,072
27 22 Optional 25 20 D 75 NEMA 1 21.7 x 11.8 x 12.0 CFW110027T6ONBZ 5,410
32 27 Optional 30 25 D 75 NEMA 1 21.7 x 11.8 x 12.0 CFW110032T6ONBZ 6,672
44 36 Optional 40 30 D 75 NEMA 1 21.7 x 11.8 x 12.0 CFW110044T6ONBZ 7,894
53 44 Optional 50 40 E 141 NEMA 1 26.6 x 13.2 x 14.1 CFW110053T6ON1NBYZ 10,572
63 53 Optional 60 50 E 141 NEMA 1 26.6 x 13.2 x 14.1 CFW110063T6ON1NBYZ 10,823
80 66 Optional 75 60 E 141 NEMA 1 26.6 x 13.2 x 14.1 CFW110080T6ON1NBYZ 11,872
107 90 Optional 100 75 E 141 NEMA 1 26.6 x 13.2 x 14.1 CFW110107T6ON1NBYZ 14,863
125 107 Optional 125 100 E 141 NEMA 1 26.6 x 13.2 x 14.1 CFW110125T6ON1NBYZ 18,128
150 122 Optional 150 125 E 141 NEMA 1 26.6 x 13.2 x 14.1 CFW110150T6ON1NBYZ 24,863
170 150 Standard 150 150 F 370 IP20 48.6 x 16.9 x 14.2 CFW110170T6ONBYZ 25,820
216 180 Standard 200 200 F 370 IP20 48.6 x 16.9 x 14.2 CFW110216T6ONBYZ 31,612
289 240 Standard 300 250 F 370 IP20 48.6 x 16.9 x 14.2 CFW110289T6ONBYZ 38,746
315 289 Standard 300 300 G 569 IP20 49.8 x 21.1 x 16.8 CFW110315T6ONBYZ 43,846
365 315 Standard 350 300 G 569 IP20 49.8 x 21.1 x 16.8 CFW110365T6ONBYZ 57,147
435 357 Standard 450 350 G 569 IP20 49.8 x 21.1 x 16.8 CFW110435T6ONBYZ 61,689
Notes: The maximum motor power ratings listed above are based on WEG 2 and 4 pole motors. For motors with different numbers of poles (ie. 6 and 8 poles), other voltages and/
or from other manufacturers, specify the VFD through the motor rated current.
* ND - Normal Duty
• 110% during 60 seconds every 10 minutes
• 150% during 3 seconds every 10 minutes
* HD - Heavy Duty
• 150% during 60 seconds every 10 minutes
• 200% during 3 seconds every 10 minutes
101
1.25Variable Frequency Drives
www.pamensky.com
CFW 11 - Table of Products - Dynamic Braking200-240V - Three Phase - with Dynamic Braking
Electrical Data Mechanical Data Purchasing Data
Current
(A)Built-In
Dynamic
Braking
Maximum Applicable Motor
FrameWeight
(lb)
Degree of
Protection
Dimensions
(in)
H x W x D
Part NumberList
PriceND* HD*
ND* HD* HP HP
142 115 Yes 50 40 E 143.3 NEMA 1 26.60 x 13.20 x 14.10 CFW110142T2ON1DBZ $13,102
180 142 Yes 60 50 E 143.3 NEMA 1 26.60 x 13.20 x 14.10 CFW110180T2ON1DBZ 18,232
211 180 Yes 75 60 E 143.3 NEMA 1 26.60 x 13.20 x 14.10 CFW110211T2ON1DBZ 23,357
380-480V - Three Phase - with Dynamic Braking
Electrical Data Mechanical Data Purchasing Data
Current
(A)Built-In
Dynamic
Braking
Maximum Applicable Motor
FrameWeight
(lb)
Degree of
Protection
Dimensions
(in)
H x W x D
Part NumberList
PriceND* HD*
ND* HD* HP HP
105 88 Yes 75 60 E 143.3 NEMA 1 26.60 x 13.20 x 14.10 CFW110105T4ON1DBZ $11,109
142 115 Yes 100 75 E 143.3 NEMA 1 26.60 x 13.20 x 14.10 CFW110142T4ON1DBZ 13,068
180 142 Yes 150 100 E 143.3 NEMA 1 26.60 x 13.20 x 14.10 CFW110180T4ON1DBZ 19,155
211 180 Yes 150 150 E 143.3 NEMA 1 26.60 x 13.20 x 14.10 CFW110211T4ON1DBZ 22,282
Notes: The maximum motor power ratings listed above are based on WEG 2 and 4 pole motors. For motors with different numbers of poles (ie. 6 and 8 poles), other voltages and/
or from other manufacturers, specify the VFD through the motor rated current.
* ND - Normal Duty
• 110% during 60 seconds every 10 minutes
• 150% during 3 seconds every 10 minutes
* HD - Heavy Duty
• 150% during 60 seconds every 10 minutes
• 200% during 3 seconds every 10 minutes
p g p p ( p ), g
m other manufacturers, specify the VFD through the motor rated current.
500-690V - Three Phase - with RFI Filter, Safety Stop and Dynamic Braking
Electrical Data Mechanical Data Purchasing Data
Current
(A)Built-In
Dynamic
Braking
Maximum Applicable Motor
FrameWeight
(lb)
Degree of
Protection
Dimensions
(in)
H x W x D
Part NumberList
PriceND* HD*
ND* HD* HP HP
22 19 Yes 20 15 D 75 IP20 21.7 x 11.8 x 12.0 CFW110022T6OYZ $6,248
27 22 Yes 25 20 D 75 IP20 21.7 x 11.8 x 12.0 CFW110027T6OYZ 6,667
32 27 Yes 30 25 D 75 IP20 21.7 x 11.8 x 12.0 CFW110032T6OYZ 8,220
44 36 Yes 40 30 D 75 IP20 21.7 x 11.8 x 12.0 CFW110044T6OYZ 9,727
53 44 Yes 50 40 E 141 IP20 26.6 x 13.2 x 14.1 CFW110053T6OYZ 12,943
63 53 Yes 60 50 E 141 IP20 26.6 x 13.2 x 14.1 CFW110063T6OYZ 13,250
80 66 Yes 75 60 E 141 IP20 26.6 x 13.2 x 14.1 CFW110080T6OYZ 14,545
107 90 Yes 100 75 E 141 IP20 26.6 x 13.2 x 14.1 CFW110107T6OYZ 18,229
125 107 Yes 125 100 E 141 IP20 26.6 x 13.2 x 14.1 CFW110125T6OYZ 22,250
150 122 Yes 150 125 E 141 IP20 26.6 x 13.2 x 14.1 CFW110150T6OYZ 25,541
101
Variable Frequency Drives1.26
www.pamensky.com
CFW 11 - AccessoriesI/O Expansion
Description Slot Part Number List Price
2 14-bit analog inputs in voltage or current
2 digital inputs
2 14-bit analog outputs in voltage or current
2 open collector type digital outputs
1 IOA-01 $1,052
2 isolated 12-bit analog inputs
2 digital inputs
2 isolated 11-bit analog outputs in voltage or current
2 open collector type digital outputs
1 IOB-01 561
8 Digital Inputs
4 Digital Outputs
(Use with Soft PLC)
1 IOC-01 419
8 Digital Inputs
8 Open Collector Digital Outputs
(Use with Soft PLC)
1 IOC-02 386
5 PTC type temperature sensor Input 1 IOE-01 626
5 PT100 type temperature sensor Input 1 IOE-02 1,631
5 KTY84 type temperature sensor Input 1 IOE-03 809
Interface with Encoder
Description Slot Part Number List Price
Incremental encoder module
5 to 12 Vdc
100 kHz
With encoder signal repeater
2 ENC-01 $461
Incremental encoder module
5 to 12 Vdc
100 kHz
2 ENC-02 404
Communication
Description Slot Part Number List Price
RS-485 Serial Communication Module (Modbus-RTU) 3 RS485-01 $212
RS-232C Serial Communication Module (Modbus-RTU) 3 RS232-01 161
RS-232C Serial Communication Module (Modbus-RTU) with DIP switch for fl ash memory prog. 3 RS232-02 179
CAN/RS-485 Interface Module (CANopen, DeviceNet and Modbus) 3 CAN/RS485-01 453
CAN Interface Module (CANopen and DeviceNet) 3 CAN-01 378
Profi bus DP-V1 Interface Module 3 PROFIBUS DP-01 512
Profi bus DP Interface Module 4 PROFDP-05 1,138
DeviceNet Interface Module 4 DEVICENET-05 1,138
EtherNet/IP Interface Module 4 ETHERNET/IP-05 1,138
RS-232 Interface Module (passive) (Modbus-RTU) 4 RS232-05 277
RS-485 Interface Module (passive) (Modbus-RTU) 4 RS485-05 333
Modbus - TCP/IP interface module 4 MODBUSTCP-05 1,680
Profi net interface module 4 PROFINETIO-05 1,939
PLC Module
Description Slot Part Number List Price
PLC functions; Ladder programming; electronic ggearbox; 9 digital inputs; 3 dry-contact digital
outputs; 3 open-collector digital ouputs; 1 analog input (14 bits); 2 analog outputs (14 bits); 2
encoder interfaces; RS-485 Modbus-RTU interface; CAN interface (CANopen, CANopen master/
slave).
1,2,3 PLC11-01 $1,960
PLC functions; Ladder programming; electronic ggearbox; 4 digital inputs; 1 dry-contact digital
outputs; 3 open-collector digital ouputs; 2 encoder interfaces; RS-485 Modbus-RTU interface; CAN
interface (CANopen, CANopen master/slave).
1,2,3 PLC11-02 1,215
101
1.27Variable Frequency Drives
www.pamensky.com
CFW 11 - AccessoriesKeypad Accessories and Cable for HMI
Description Part Number List Price
CFW 11 Keypad HMI-01 $318
Frame for keypad remote assembly, IP56 RHMIF-01 60
Blank cover for keypad slot HMID-01 47
1m (3.3ft) Remote Keypad Cable IHM CAB-RS-1M 47
2m (6.6ft) Remote Keypad Cable IHM CAB-RS-2M 52
3m (10ft) Remote Keypad Cable IHM CAB-RS-3M 57
5m (16ft) Remote Keypad Cable IHM CAB-RS-5M 65
7.5m (25ft) Remote Keypad Cable IHM CAB-RS-7.5M 78
10m (33ft) Remote Keypad Cable IHM CAB-RS-10M 88
Shielding Kits and Exctractable Mounting Kits
Description Part Number List Price
Power cable shielding kit for frame A PCSA-01 $42
Power cable shielding kit for frame B PCSB-01 44
Power cable shielding kit for frame C PCSC-01 47
NEMA 1 Kits
Description Part Number List Price
NEMA 1 - conduit kit kit for frame A KN1A-01 $73
NEMA 1 - conduit kit kit for frame B KN1B-01 86
NEMA 1 - conduit kit kit for frame C KN1C-01 99
Dynamic Braking
Description Part Number List Price
External Dynamic Braking Module DBW03 $5,904
101
Variable Frequency Drives1.28
www.pamensky.com
CFW 11 - Technical Data
Power Supply and
Power Range
Voltage and
power range
Single-Phase 200-240 V: 200/220/230/240 V (+10%/-15%)
Three-Phase
200-240 V: 200/220/230/240 V (+10%/-15%)
380-480 V: 380/400/415/440/460/480 V (+10%/-15%)
500-690 V: 525/575/600/690 V (+10%/-15%)
Frequency 50 / 60 Hz +-2% (48 to 63 Hz)
Displacement factor Greater than 0.98
Effi ciency Greater than 0.97
Motor
Voltage Three Phase, 0 up to power supply voltage
Frequency 0 to 400 Hz
Switching
Frequency
Standard: 5kHz
Options available: 2.5 / 5 / 10 kHz
Overload
Normal Duty Cycle 110% for 1 min every 10min
150% for 3 sec every 10min
Heavy Duty Cycle150% for 1 min every 10min
200% for 3 sec every 10min
Time (ramps)Acceleration 0 to 999 seconds
Deceleration 0 to 999 seconds
Performance
Scalar (V/f)
Speed
Control
Regulation: 1% of rated speed
Speed variation range: 1:20
Voltage Vector
(VVW)
Regulation: 1% of rated speed
Speed variation range: 1:30
Sensorless VectorRegulation: 0.5% of rated speed
Speed variation range: 1:100
Vector with
Encoder
(with accessory
ENC-01 or ENC-
02)
Regulation: +/- 0.01% of rated speed with 14-bit analog input (IOA)
Regulation: +/- 0.01% of rated speed with digital reference (keyboard, serial
fi eldbus, electronic potentiometer, multispeed)
Regulation: +/- 0.05% of rated speed with 12-bit analog input
Torque
Control
Range: 10 to 180%
Regulation: +/- 5% of rated torque
Sensorless VectorRange: 20 to 180%
Regulation: +/-10% of rated torque (above 3 Hz)
Inputs and
Outputs (I/Os)
in the Standard
Product
Inputs
Digital 6 isolated inputs, 24 Vdc, programmable functions
Analog
2 differential inputs isolated by differential amplifi er, programmable functions
Resolution:
- AI1: 12 bits
- AI2: 11 bits + signal
Signals: (0 to 10) V, (0 to 20) mA or (4 to 20) mA
Impedance:
- 400 kΩ for signal (0 to 10) V
- 500 Ω for signal (0 to 20) mA or (4 to 20) mA
Outputs
Relay 3 relays with NA/NF (NO/NC) contacts, 240 Vac / 1A, programmable functions
Analog
2 isolated outputs, programmable functions
Resolution: 11 bits
Load:
0 to 10 V: RL >= 10 kΩ
0 to 20 mA or 4 to 20 mA: RL < 500Ω
Available supply to user 24 Vdc + -20%, 500 mA
Environment
Temperature of
Operation
-10 to 50°C for frame Size A,B,C and D; -10 to 45°C for frame Size E and F; -10 to 40°C for frame Size G with 720A
Up to 60°C with current derating (2% for each 1°C above 50°C)
Humidity 5 to 90% without condensation
Altitude 0 to 1000 meters
Up to 4000 meters with current reduction (1% for every 100 meters above 1000 meters)
Degree of
Protection
IP21 Standard for frame sizes A, B, C. For frame size D the top cover kit has to be added. Frame Sizes E, F and G option not available
IP20 Standard for frame sizes D, E, F and G. Frame Sizes A, B and C the top cover has to be removed.
NEMA1 Standard for frame Size D. Optinal for frame sizes A, B, C, E, F and G
IP54 Frame Sizes 1, 2 and 3
Braking Methods
Rheostatic BrakingSupply available to user
External braking resistor (not provided)
Optimal Braking Does not need braking resistor
DC Braking Direct current applied to the motor
101
1.29Variable Frequency Drives
www.pamensky.com
CFW 11 - Technical Data
Communication
Profi bus DPPROFIBUS DP-01 (slot 3)
PROFDP-05 (slot 4)
DeviceNet
CAN/RS485-01 (slot 3)
CAN-01 (slot 3)
DEVICENET-05 (slot4)
CANopenCAN/RS485-01 (slot 3)
CAN-01 (slot 3)
CANopen Master/Slave PLC11-01 (slot 1/2/3)
EtherNet TCP/IP ETHERNET/IP-05 (slot 4)
RS485 - ModBus RTU
RS485-01
CAN/RS485-01
RS485-05
RS232 - ModBus RTURS232-01
RS232-05
USB
Built-into the standard product
Communication with SUPERDRIVE G2 Software
Communication with WLP Software used for programming and monitoring the Soft
PLC function and the PLC11-01 accessory
Protections
Overcurrent / short circuit
Under / overvoltage in the power circuit
Phase loss
Overtemperature in the inverter (IGBTs, rectifi er and internal air in the electronic cards)
Overtemperature in the motor
Overload in the braking resistor
Overload in the IGBTs
Overload in the motor
Fault / external alarm
Fault in the CPU or memory
Phase-to-ground short circuit at the output
Fault in the heatsink fan
Overspeed of motor
Incorrect connection of encoder
Safety Standards
UL 508C
Power conversion equipment
UL 840
Insulation coordination including clearances and creepage distances for electrical equipment
EN 61800-5-1
Safety requirements electrical, thermal and energy
EN 50178
Electronic equipment for use in power installations
EN 60204-1
Safety of machinery.
Electrical equipment of machines.
Part 1: General requirements.
Note: In order to have a machine in conformity with this norm, the machine manufacturer is responsible for the installation of an emergency shutdown device and
an equipment for network sectioning
EN 60146 (IEC 146)
Semiconductor converters
EN 61800-2
Adjustable speed electrical power drive systems
Part 2: General requirements – rating specifi cations for low voltage adjustable frequency a.c. power drive systems
Mechanical
Construction Stds.
EN 60529 - Degrees of protection provided by enclosures (IP Code)
UL 50 - Enclosures for electrical equipment
Electromagnetic
Compatibility
Standards
EN 61800-3 - Adjustable speed electrical power drive systems
Part 3: EMC product standard including specifi c test methods
EN 55011 - Limits and methods of measurement of radio disturbance characteristics of industrial, scientifi c and medical (ISM)
radio-frequency equipment
CISPR 11 - Industrial, scientifi c and medical (ISM)radio-frequency equipment Electromagnetic disturbance characteristics.
Limits and methods of measurement
EN 61000-4-2 - Electromagnetic Compatibility Standards (EMC)
Part 4: Testing and measurement techniques
Section 2: Electrostatic discharge immunity test
EN 61000-4-3 - Electromagnetic Compatibility Standards (EMC)
Part 4: Testing and measurement techniques
Section 3:Radiated, radiofrequency, electromagnetic fi eld immunity test
EN 61000-4-4 - Electromagnetic Compatibility Standards (EMC)
Part 4: Testing and measurement techniques
Section 4: Electrical fast transient / burst immunity test
EN 61000-4-5 - Electromagnetic Compatibility Standards (EMC)
Part 4: Testing and measurement techniques
Section 5: Surge immunity test
EN 61000-4-6 - Electromagnetic Compatibility Standards (EMC)
Part 4: Testing and measurement techniques
Section 6: Immunity to conducted disturbances, induced by radio-frequency fi elds
101
Variable Frequency Drives1.30
www.pamensky.com
CFW 11M - Modular Variable Frequency Drive
The CFW 11M is the new generation of WEG frequency inverters for large power ranges. It ranges
from 350 to 2500HP rated at 380-480V / 500-600V / 660-690V with the option for 6 or 12 pulses.
Standard Features
• Plug and play philosophy (connect and
use) enables quick and easy installation of
accessories and options
• USB for computer connection for using
SUPERDRIVE G2 programming and
monitoring software
• Human-Machine Interface (HMI) with backlit
graphic display and soft-keys, greatly
facilitates inverter programming and operation
• Intelligent thermal management enables full
protection of IGBTs, monitoring of heatsink
and internal air temperature
• Automatic control of the heatsink fan with
speed sensor (additional protection) and
easily detachable from the unit for cleaning
and maintenance
• Normal Duty and Heavy Duty ratings to adapt
optimally to all kinds of loads
• Protection with failure and alarm warnings
• Motor overload protection in compliance with
IEC 60947-4-2/UL 508 C
• On board memory allows user to create
functions without the need to use an external
PLC (soft-PLC via IEC61131-3 programming
software)
• Guided start-up simplifi es initial user
programming
• Real time clock
• TRACE / SCOPE function to assist with
the start-up and system diagnostics with
SUPERDRIVE G2
Optional Features
• Interface for incremental encoder 5 to 12Vdc
• Interface for RS-485 serial communication
(modbus)
• Interface for RS-232C serial communication
• CAN interface
• Profi bus DP interface
• PLC functions; IEC programming
• Devicenet 4 interface
• Ethernet IP interface
• Blind cover for slot HMI
• Frame for remote HMI
• Conduit kit
101
1.31Variable Frequency Drives
www.pamensky.com
CFW 11M - Specifi cation Table380-480V - Three Phase
Electrical Data Mechanical Data Purchasing Data
Current
(A)
Maximum Applicable Motor
Degree of
Protection
6 Pulse 12 Pulse
Part NumberNormal Duty (ND) Heavy Duty (HD) Dimensions (in)
H x W x D
Dimensions (in)
H x W x DND* HD* HP KW HP KW
600 515 500 370 450 330 IP41 90.55 x 55.12 x 31.50 90.55 x 86.61 x 31.50 AFW11M0600T4Z
1140 979 900 700 800 590 IP41 90.55 x 55.12 x 31.50 90.55 x 86.61 x 31.50 AFW11M1140T4Z
1710 1468 1400 1050 1200 900 IP41 90.55 x 70.87 x 31.50 90.55 x 102.36 x 31.50 AFW11M1710T4Z
2280 1957 1800 1400 1600 1200 IP41 90.55 x 78.74 x 31.50 90.55 x 110.24 x 31.50 AFW11M2280T4Z
2850 2446 2300 1750 2000 1500 IP41 90.55 x 102.36 x 31.50 90.55 x 125.98 x 31.50 AFW11M2850T4Z
500-600V - Three Phase
Electrical Data Mechanical Data Purchasing Data
Current
(A)
Maximum Applicable Motor
Degree of
Protection
6 Pulse 12 Pulse
Part NumberNormal Duty (ND) Heavy Duty (HD) Dimensions (in)
H x W x D
Dimensions (in)
H x W x DND* HD* HP KW HP KW
470 418 500 370 400 300 IP41 90.55 x 55.12 x 31.50 90.55 x 86.61 x 31.50 AFW11M0470T5Z
893 794 900 700 800 590 IP41 90.55 x 55.12 x 31.50 90.55 x 86.61 x 31.50 AFW11M0893T5Z
1339 1191 1400 1050 1250 900 IP41 90.55 x 70.87 x 31.50 90.55 x 102.36 x 31.50 AFW11M1340T5Z
1786 1588 1800 1400 1600 1200 IP41 90.55 x 78.74 x 31.50 90.55 x 110.24 x 31.50 AFW11M1786T5Z
2232 1985 2300 1750 2000 1500 IP41 90.55 x 102.36 x 31.50 90.55 x 125.98 x 31.50 AFW11M2232T5Z
660-690V - Three Phase *CE certifi cation only
Electrical Data Mechanical Data Purchasing Data
Current
(A)
Maximum Applicable Motor
Degree of
Protection
6 Pulse 12 Pulse
Part NumberNormal Duty (ND) Heavy Duty (HD) Dimensions (in)
H x W x D
Dimensions (in)
H x W x DND* HD* HP KW HP KW
427 340 500 370 400 300 IP41 90.55 x 55.12 x 31.50 90.55 x 55.12 x 31.50 AFW11M0427T6Z
811 646 1000 750 800 590 IP41 90.55 x 55.12 x 31.50 90.55 x 62.99 x 31.50 AFW11M0811T6Z
1216 969 1500 1100 1250 900 IP41 90.55 x 62.99 x 31.50 90.55 x 102.36 x 31.50 AFW11M1217T6Z
1622 1292 2000 1500 1600 1200 IP41 90.55 x 78.74 x 31.50 90.55 x 110.24 x 31.50 AFW11M1622T6Z
2028 1615 2500 1850 2000 1500 IP41 90.55 x 94.49 x 31.50 90.55 x 125.98 x 31.50 AFW11M2028T6Z
101
Variable Frequency Drives1.32
www.pamensky.com
CFW 11M - AccessoriesI/O Expansion
Description Slot Part Number List Price
2 14-bit analog inputs in voltage or current
2 digital inputs
2 14-bit analog outputs in voltage or current
2 open collector type digital outputs
1 IOA-01 $1,052
2 isolated 12-bit analog inputs
2 digital inputs
2 isolated 11-bit analog outputs in voltage or current
2 open collector type digital outputs
1 IOB-01 561
8 Digital Inputs
4 Digital Outputs
(Use with Soft PLC)
1 IOC-01 419
8 Digital Inputs
8 Open Collector Digital Outputs
(Use with Soft PLC)
1 IOC-02 386
5 PTC type temperature sensor Input 1 IOE-01 626
5 PT100 type temperature sensor Input 1 IOE-02 1,631
5 KTY84 type temperature sensor Input 1 IOE-03 809
Interface with Encoder
Description Slot Part Number List Price
Incremental encoder module
5 to 12 Vdc
100 kHz
With encoder signal repeater
2 ENC-01 $461
Incremental encoder module
5 to 12 Vdc
100 kHz
2 ENC-02 404
Communication
Description Slot Part Number List Price
RS-485 Serial Communication Module (Modbus-RTU) 3 RS485-01 $212
RS-232C Serial Communication Module (Modbus-RTU) 3 RS232-01 161
RS-232C Serial Communication Module (Modbus-RTU) with DIP switch for fl ash memory prog. 3 RS232-02 179
CAN/RS-485 Interface Module (CANopen, DeviceNet and Modbus) 3 CAN/RS485-01 453
CAN Interface Module (CANopen and DeviceNet) 3 CAN-01 378
Profi bus DP-V1 Interface Module 3 PROFIBUS DP-01 512
Profi bus DP Interface Module 4 PROFDP-05 1,138
DeviceNet Interface Module 4 DEVICENET-05 1,138
EtherNet/IP Interface Module 4 ETHERNET/IP-05 1,138
RS-232 Interface Module (passive) (Modbus-RTU) 4 RS232-05 277
RS-485 Interface Module (passive) (Modbus-RTU) 4 RS485-05 333
Modbus - TCP/IP interface module 4 MODBUSTCP-05 1,680
Profi net interface module 4 PROFINETIO-05 1,939
PLC Module
Description Slot Part Number List Price
PLC functions; Ladder programming; electronic ggearbox; 9 digital inputs; 3 dry-contact digital
outputs; 3 open-collector digital ouputs; 1 analog input (14 bits); 2 analog outputs (14 bits); 2
encoder interfaces; RS-485 Modbus-RTU interface; CAN interface (CANopen, CANopen master/
slave).
1,2,3 PLC11-01 $1,960
PLC functions; Ladder programming; electronic ggearbox; 4 digital inputs; 1 dry-contact digital
outputs; 3 open-collector digital ouputs; 2 encoder interfaces; RS-485 Modbus-RTU interface; CAN
interface (CANopen, CANopen master/slave).
1,2,3 PLC11-02 1,215
101
1.33Variable Frequency Drives
www.pamensky.com
CFW 11M - AccessoriesKeypad Accessories and Cable for HMI
Description Part Number List Price
CFW 11 Keypad HMI-01 $318
Frame for keypad remote assembly, IP56 RHMIF-01 60
Blank cover for keypad slot HMID-01 47
1m (3.3ft) Remote Keypad Cable IHM CAB-RS-1M 47
2m (6.6ft) Remote Keypad Cable IHM CAB-RS-2M 52
3m (10ft) Remote Keypad Cable IHM CAB-RS-3M 57
5m (16ft) Remote Keypad Cable IHM CAB-RS-5M 65
7.5m (25ft) Remote Keypad Cable IHM CAB-RS-7.5M 78
10m (33ft) Remote Keypad Cable IHM CAB-RS-10M 88
Dynamic Braking
Description Part Number List Price
External Dynamic Braking Module DBW03 $5,904
101
Variable Frequency Drives1.34
www.pamensky.com
CFW 11M - Technical Data
Power Supply and
Power Range
Voltage and
power rangeThree-Phase
380-480V: 380/400/415/440/480 V (+10%/-15%)
500-600V: 525/575/600 V (+10%/-15%)
660-690V: 660 (+10%/-15%) /690 V
Frequency 50 / 60 Hz +-2% (48 to 63 Hz)
Displacement factor Greater than 0.98
Effi ciency Greater than 0.97
Motor
Voltage Three Phase, 0 up to power supply voltage
Frequency 0 to 400 Hz
Switching
Frequency
Standard: 5kHz
Options available: 2.5 / 5 / 10 kHz
Overload
Normal Duty Cycle 110% for 1 min every 10min
150% for 3 sec every 10min
Heavy Duty Cycle150% for 1 min every 10min
200% for 3 sec every 10min
Time (ramps)Acceleration 0 to 999 seconds
Deceleration 0 to 999 seconds
Performance
Scalar (V/f)
Speed
Control
Regulation: 1% of rated speed
Speed variation range: 1:20
Voltage Vector
(VVW)
Regulation: 1% of rated speed
Speed variation range: 1:30
Sensorless VectorRegulation: 0.5% of rated speed
Speed variation range: 1:100
Vector with
Encoder
(with accessory
ENC-01 or ENC-
02)
Regulation: +/- 0.01% of rated speed with 14-bit analog input (IOA)
Regulation: +/- 0.01% of rated speed with digital reference (keyboard, serial
fi eldbus, electronic potentiometer, multispeed)
Regulation: +/- 0.05% of rated speed with 12-bit analog input
Torque
Control
Range: 10 to 180%
Regulation: +/- 5% of rated torque
Sensorless VectorRange: 20 to 180%
Regulation: +/-10% of rated torque (above 3 Hz)
Inputs and
Outputs (I/Os)
in the Standard
Product
Inputs
Digital 6 isolated inputs, 24 Vdc, programmable functions
Analog
2 differential inputs isolated by differential amplifi er, programmable functions
Resolution:
- AI1: 12 bits
- AI2: 11 bits + signal
Signals: (0 to 10) V, (0 to 20) mA or (4 to 20) mA
Impedance:
- 400 kΩ for signal (0 to 10) V
- 500 Ω for signal (0 to 20) mA or (4 to 20) mA
Outputs
Relay 3 relays with NO/NC contacts, 240 Vac / 1A, programmable functions
Analog
2 isolated outputs, programmable functions
Resolution: 11 bits
Load:
0 to 10 V: RL >= 10 kΩ
0 to 20 mA or 4 to 20 mA: RL < 500Ω
Available supply to user 24 Vdc + -20%, 500 mA
Environment
Temperature of
Operation
- 10ºC to 50ºC
Up to 60°C with current derating (2% for each 1°C above 50°C)
Humidity 5 to 90% without condensation
Altitude 0 to 1000 meters
Up to 4000 meters with current reduction (1% for every 100 meters above 1000 meters)
Degree of
ProtectionIP41
Braking Methods
Rheostatic BrakingSupply available to user
External braking resistor (not provided)
Optimal Braking Does not need braking resistor
DC Braking Direct current applied to the motor
101
1.35Variable Frequency Drives
www.pamensky.com
CFW 11M - Technical Data
Communication
Profi bus DP PROFIBUS DP (slot 4)
DeviceNet
CAN/RS485-01 (slot 3)
CAN-01 (slot 3)
DEVICENET-05 (slot4)
CANopenCAN/RS485-01 (slot 3)
CAN-01 (slot 3)
CANopen Master/Slave PLC11-01 (slot 1/2/3)
EtherNet TCP/IP ETHERNET/IP-05 (slot 4)
RS485 - ModBus RTU
RS485-01
CAN/RS485-01
RS485-05
RS232 - ModBus RTURS232-01
RS232-05
USB
Built-into the standard product
Communication with SUPERDRIVE G2 Software
Communication with WLP Software used for programming and monitoring the Soft
PLC function and the PLC11-01 accessory
Protections
Overcurrent / short circuit
Under / overvoltage in the power circuit
Phase loss
Overtemperature in the inverter (IGBTs, rectifi er and internal air in the electronic cards)
Overtemperature in the motor
Overload in the braking resistor
Overload in the IGBTs
Overload in the motor
Fault / external alarm
Fault in the CPU or memory
Phase-to-ground short circuit at the output
Fault in the heatsink fan
Overspeed of motor
Incorrect connection of encoder
Safety Standards
UL 508C
Power conversion equipment
UL 840
Insulation coordination including clearances and creepage distances for electrical equipment
EN 61800-5-1
Safety requirements electrical, thermal and energy
EN 50178
Electronic equipment for use in power installations
EN 60204-1
Safety of machinery.
Electrical equipment of machines.
Part 1: General requirements.
Note: In order to have a machine in conformity with this norm, the machine manufacturer is responsible for the installation of an emergency shutdown device and
an equipment for network sectioning
EN 60146 (IEC 146)
Semiconductor converters
EN 61800-2
Adjustable speed electrical power drive systems
Part 2: General requirements – rating specifi cations for low voltage adjustable frequency a.c. power drive systems
Mechanical
Construction
Standards
EN 60529 - Degrees of protection provided by enclosures (IP Code)
UL 50 - Enclosures for electrical equipment
Electromagnetic
Compatibility
Standards (EMC)
EN 61800-3 - Adjustable speed electrical power drive systems
Part 3: EMC product standard including specifi c test methods
EN 55011 - Limits and methods of measurement of radio disturbance characteristics of industrial, scientifi c and medical (ISM)
radio-frequency equipment
CISPR 11 - Industrial, scientifi c and medical (ISM)radio-frequency equipment Electromagnetic disturbance characteristics.
Limits and methods of measurement
EN 61000-4-2 - Electromagnetic Compatibility Standards (EMC)
Part 4: Testing and measurement techniques
Section 2: Electrostatic discharge immunity test
EN 61000-4-3 - Electromagnetic Compatibility Standards (EMC)
Part 4: Testing and measurement techniques
Section 3:Radiated, radiofrequency, electromagnetic fi eld immunity test
EN 61000-4-4 - Electromagnetic Compatibility Standards (EMC)
Part 4: Testing and measurement techniques
Section 4: Electrical fast transient / burst immunity test
EN 61000-4-5 - Electromagnetic Compatibility Standards (EMC)
Part 4: Testing and measurement techniques
Section 5: Surge immunity test
EN 61000-4-6 - Electromagnetic Compatibility Standards (EMC)
Part 4: Testing and measurement techniques
Section 6: Immunity to conducted disturbances, induced by radio-frequency fi elds
101
Variable Frequency Drives1.36
www.pamensky.com
CFW 700 - Variable Frequency Drive
Standard Features
• Built-in DC Link Reactor
• Encoder Interface
• RS485 Port for Modbus-RTU
communication
• 8 Digital Inputs / 5 Digital Outputs.
• 2 Analog Inputs / 2 Analog Outputs.
• Common DC bus Connection
• Multi-speed: up to 8 preset speeds can
be programmed.
• PID regulation: eliminates the use of an
external controller for closed loop control,
thus great performance of speed and
torque can be achieved.
• Ride through: embedded in the CFW700
control this function avoids the drive from
tripping during a power outage.
• Speed/Torque regulation: open and
closed loop (encoder feedback required).
• Flying start: it is able to start smoothly
a motor connected to a rotating load
regardless rotation direction.
• Control options for DC bus regulation:
prevents the drive from tripping when
short deceleration time is required, in
demanding applications with high inertia
loads.
• S ramp: in applications requiring smooth
start-up (e.g. beverage industry) this
function can avoid production losses
traditional start-up incurs.
• Three-wire Start/Stop control: retentive
contact can command the drive to start/
stop the motor. (Soft PLC)
• Electronic potentiometer: increase and
decrease motor speed using pushbutton
control
• Skip frequency: for some applications
specifi c frequencies must be avoided to
protect against resonance effects.
• Motor thermal curve adjustment: separate
adjustment between the motor and drive
allows for more effective protection for
overload cycles.
• Copy function: by using the fl ash memory
card MMF-02 parameter settings can
be easily stored ensuring integrity and
safety in case replacement of the drive is
required.
Factory Options
• Safety Stop
• RFI Filter
• 24 VDC power input option for control section
Designed for controlling squirrel cage three-
phase induction motors the new CFW700 is a
general purpose drive that gives costumers the
fl exibility needed for the control of applications
ranging from simple speed control to more
demanding ones including torque control.
101
1.37Variable Frequency Drives
www.pamensky.com
CFW 700 - Part Number Specifi cation
1 32 654 7 8 9 10
-- Y1 W120DB4TA 03P6CFW700
1. CFW-700 Variable Frequency Drive
2. Frame Size: A, B, C, D or E
3. Output Rated Current: 200-240V 380-480V 500-600V
06P0 = 6.0 A 03P6 = 3.6 A 02P9 = 2.9 A
07P0 = 7.0 A 05P0 = 5.0 A 04P2 = 4.2 A
10P0 = 10 A 06P0 = 6 A 07P0 = 7 A
13P0 = 13 A 07P0 = 7.0 A 10P0 = 10 A
16P0 = 16 A 10P0 = 10 A 12P0 = 12 A
24P0 = 24 A 13P5 = 13.5 A 17P0 = 17 A
28P0 = 28 A 17P0 = 17 A 22P0 = 22 A
33P5 = 33.5 A 24P0 = 24 A 27P0 = 27 A
45P0 = 45 A 31P0 = 31 A 32P0 = 32 A
54P0 = 54 A 38P0 = 38 A 44P0 = 44 A
70P0 = 70 A 45P0 = 45 A 53P0 = 53 A
86P0 = 86 A 58P5 = 58.5 A 63P0 = 63 A
0105 = 105 A 70P5 = 70.5 A 80P0 = 80 A
0142 = 142 A 88P0 = 88 A 0107 = 107 A
0180 = 180 A 0105 = 105 A 0125 = 125 A
0211 = 211 A 0142 = 142 A 0150 = 150 A
0180 = 180 A
0211 = 211 A
* Selection Table for 2
4. Power Supply: S = single-phase
T = three-phase
B = single-phase or three-phase
5. Power Supply Voltage: 2 = 200-240 V (Frames A, B, C, D)
220-230 V (Frame E)
4 = 380-480 V
5 = 500-600 V
6. Braking Module: NB = no built-in IGBT
DB = with built-in braking IGBT (standard for frames
A, B, C, D)
7. Enclosure: 20 = IP 20 (standard for frames A, B, C and E)
N1 = Nema 1 (standard for frame D)
21 = IP21
8. RFI Filter: Blank = standard
9. Safety Stop: Blank = standard (without safety stop function)
Y1 = with safety stop function according to
EN-954-1 category 3
10. External Electronic Supply for Control:
Blank = Control circuit is fed by the inverter SMPS
W1 = Control circuit is supplied from an external +24Vdc
Example: CFW700B28POT2DB20
101
Variable Frequency Drives1.38
www.pamensky.com
CFW 700 - Table of Products
Notes: The maximum motor power ratings listed above are based on WEG 2 and 4 pole motors. For motors with different numbers of poles (ie. 6 and 8 poles), other voltages and/
or from other manufacturers, specify the VFD through the motor rated current.
200-240V - Single Phase
Electrical Data Mechanical Data Purchasing Data
Current
(A)Built-In
Dynamic
Braking
Maximum Applicable Motor
FrameWeight
(lb)
Degree of
Protection
Dimensions
(in)
H x W x D
Part NumberList
PriceND* HD*
ND* HD* HP HP
6 5 Standard 1.5 1 A 13.9 NEMA 1 12.02 x 5.71 x 8.94 CFW700A06POB2DBN1 $1,699
7 7 Standard 2 2 A 13.9 NEMA 1 12.02 x 5.71 x 8.94 CFW700A07POB2DBN1 1,748
10 10 Standard 3 3 A 13.9 NEMA 1 12.02 x 5.71 x 8.94 CFW700A10POS2DBN1 1,854
220-230V - Three Phase
Electrical Data Mechanical Data Purchasing Data
Current
(A)Built-In
Dynamic
Braking
Maximum Applicable Motor
FrameWeight
(lb)
Degree of
Protection
Dimensions
(in)
H x W x D
Part NumberList
PriceND* HD*
ND* HD* HP HP
142 115 Optional 50 40 E 143.3 NEMA 1 28.94 x 13.20 x 14.10 CFW700E0142T2NBN1C3 $10,796
180 142 Optional 60 50 E 143.3 NEMA 1 32.63 x 13.20 x 14.10 CFW700E0180T2NBN1C3 15,125
211 180 Optional 75 60 E 143.3 NEMA 1 32.63 x 13.20 x 14.10 CFW700E0211T2NBN1C3 19,767
200-240V - Three Phase
Electrical Data Mechanical Data Purchasing Data
Current
(A)Built-In
Dynamic
Braking
Maximum Applicable Motor
FrameWeight
(lb)
Degree of
Protection
Dimensions
(in)
H x W x D
Part NumberList
PriceND* HD*
ND* HD* HP HP
6 5 Standard 1.5 1 A 13.9 NEMA 1 12.02 x 5.71 x 8.94 CFW700A06POB2DBN1 $1,699
7 7 Standard 2 2 A 13.9 NEMA 1 12.02 x 5.71 x 8.94 CFW700A07POB2DBN1 1,748
7 5.5 Standard 2 1 A 13.9 NEMA 1 12.02 x 5.71 x 8.94 CFW700A07POT2DBN1 1,626
10 8 Standard 3 2 A 13.9 NEMA 1 12.02 x 5.71 x 8.94 CFW700A10POT2DBN1 1,724
13 11 Standard 3 3 A 13.9 NEMA 1 12.02 x 5.71 x 8.94 CFW700A13POT2DBN1 1,794
16 13 Standard 5 3 A 13.9 NEMA 1 12.02 x 5.71 x 8.94 CFW700A16POT2DBN1 1,923
24 20 Standard 7.5 5 B 22.9 NEMA 1 13.82 x 7.46 x 8.94 CFW700B24POT2DBN1 2,371
28 24 Standard 10 7.5 B 22.9 NEMA 1 13.82 x 7.46 x 8.94 CFW700B28POT2DBN1 2,417
33.5 28 Standard 10 10 B 22.9 NEMA 1 13.82 x 7.46 x 8.94 CFW700B33POT2DBN1 2,748
45 36 Standard 15 10 C 45.2 NEMA 1 17.64 x 8.67 x 11.52 CFW700C45POT2DBN1 3,270
54 45 Standard 20 15 C 45.2 NEMA 1 17.64 x 8.67 x 11.52 CFW700C54POT2DBN1 4,014
70 56 Standard 25 20 C 45.2 NEMA 1 17.64 x 8.67 x 11.52 CFW700C70POT2DBN1 4,676
86 70 Standard 30 25 D 120.2 NEMA 1 21.63 x 11.81 x 12.00 CFW700D86POT2DBN1 5,880
105 86 Standard 40 30 D 120.2 NEMA 1 21.63 x 11.81 x 12.00 CFW700D0105T2DBN1 7,555
* ND - Normal Duty
• 110% during 60 seconds every 10 minutes
• 150% during 3 seconds every 10 minutes
* HD - Heavy Duty
• 150% during 60 seconds every 10 minutes
• 200% during 3 seconds every 10 minutes
gs listed above are based on WEG 2 and 4 pole motors. For motors with different numbers of poles (ie. 6 and 8 poles), other voltages and/
ecify the VFD through the motor rated current.
60 E 143.3 NEMA 1 32.63 x 13.20 x 14.10 CFW700E0211T2NBN1C3 19,767
utes
es
* HD - Heavy Duty
• 150% during 60 seconds every 10 minutes
• 200% during 3 seconds every 10 minutes
101
1.39Variable Frequency Drives
www.pamensky.com
380-480V - Three Phase
Electrical Data Mechanical Data Purchasing Data
Current
(A)Built-In
Dynamic
Braking
Maximum Applicable Motor
FrameWeight
(lb)
Degree of
Protection
Dimensions
(in)
H x W x D
Part NumberList
PriceND* HD*
ND* HD* HP HP
3.6 3.6 Standard 2 2 A 13.9 NEMA 1 12.02 x 5.71 x 8.94 CFW700A03P6T4DBN1 $1,670
5 5 Standard 3 3 A 13.9 NEMA 1 12.02 x 5.71 x 8.94 CFW700A05P0T4DBN1 1,771
7 5.5 Standard 3 3 A 13.9 NEMA 1 12.02 x 5.71 x 8.94 CFW700A07P0T4DBN1 1,833
10 10 Standard 5 5 A 13.9 NEMA 1 12.02 x 5.71 x 8.94 CFW700A10P0T4DBN1 1,887
13.5 11 Standard 7.5 7.5 A 13.9 NEMA 1 12.02 x 5.71 x 8.94 CFW700A13P5T4DBN1 1,978
17 13.5 Standard 10 7.5 B 22.9 NEMA 1 13.82 x 7.46 x 8.94 CFW700B17P0T4DBN1 2,334
24 19 Standard 15 10 B 22.9 NEMA 1 13.82 x 7.46 x 8.94 CFW700B24P0T4DBN1 2,820
31 25 Standard 20 15 B 22.9 NEMA 1 13.82 x 7.46 x 8.94 CFW700B31P0T4DBN1 3,549
38 33 Standard 25 20 C 45.2 NEMA 1 17.64 x 8.67 x 11.52 CFW700C38P0T4DBN1 4,224
45 38 Standard 30 25 C 45.2 NEMA 1 17.64 x 8.67 x 11.52 CFW700C45P0T4DBN1 5,317
58.5 47 Standard 40 30 C 45.2 NEMA 1 17.64 x 8.67 x 11.52 CFW700C58P5T4DBN1 6,576
70.5 61 Standard 50 40 D 120.2 NEMA 1 21.63 x 11.81 x 12.00 CFW700D70P5T4DBN1 7,129
88 73 Standard 60 50 D 120.2 NEMA 1 21.63 x 11.81 x 12.00 CFW700D88P0T4DBN1 8,524
105 88 Optional 75 60 E 143.3 NEMA 1 28.94 x 13.20 x 14.10 CFW700E0105T4NBN1C3 9,902
142 115 Optional 100 75 E 143.3 NEMA 1 28.94 x 13.20 x 14.10 CFW700E0142T4NBN1C3 11,647
180 142 Optional 150 100 E 143.3 NEMA 1 32.63 x 13.20 x 14.10 CFW700E0180T4NBN1C3 17,079
211 180 Optional 150 150 E 143.3 NEMA 1 32.63 x 13.20 x 14.10 CFW700E0211T4NBN1C3 19,863
500-600V - Three Phase
Electrical Data Mechanical Data Purchasing Data
Current
(A)Built-In
Dynamic
Braking
Maximum Applicable Motor
FrameWeight
(lb)
Degree of
Protection
Dimensions
(in)
H x W x D
Part NumberList
PriceND* HD*
ND* HD* HP HP
2.9 2.7 Standard 2 2 B 22.9 NEMA 1 13.82 x 7.46 x 8.94 CFW700B02P9T5DBN1 $2,089
4.2 3.8 Standard 3 2 B 22.9 NEMA 1 13.82 x 7.46 x 8.94 CFW700B04P2T5DBN1 2,169
7 6.5 Standard 5 5 B 22.9 NEMA 1 13.82 x 7.46 x 8.94 CFW700B07P0T5DBN1 2,283
10 9 Standard 7.5 7.5 B 22.9 NEMA 1 13.82 x 7.46 x 8.94 CFW700B10P0T5DBN1 2,464
12 10 Standard 10 7.5 B 22.9 NEMA 1 13.82 x 7.46 x 8.94 CFW700B12P0T5DBN1 2,603
17 17 Standard 15 15 B 22.9 NEMA 1 13.82 x 7.46 x 8.94 CFW700B17P0T5DBN1 3,035
22 19 Optional 20 15 D 120.2 NEMA 1 21.63 x 11.81 x 12.00 CFW700D22P0T5NBN1 4,552
27 22 Optional 25 20 D 120.2 NEMA 1 21.63 x 11.81 x 12.00 CFW700D27P0T5NBN1 4,847
32 27 Optional 30 25 D 120.2 NEMA 1 21.63 x 11.81 x 12.00 CFW700D32P0T5NBN1 6,261
44 36 Optional 40 30 D 120.2 NEMA 1 21.63 x 11.81 x 12.00 CFW700D44P0T5NBN1 7,408
53 44 Optional 50 40 E 143.3 NEMA 1 28.94 x 13.20 x 14.10 CFW700E53P0T5NBN1C3 9,365
63 53 Optional 60 50 E 143.3 NEMA 1 28.94 x 13.20 x 14.10 CFW700E63P0T5NBN1C3 10,676
80 66 Optional 75 60 E 143.3 NEMA 1 28.94 x 13.20 x 14.10 CFW700E80P0T5NBN1C3 11,306
107 90 Optional 100 75 E 143.3 NEMA 1 28.94 x 13.20 x 14.10 CFW700E0107T5NBN1C3 13,604
125 107 Optional 125 100 E 143.3 NEMA 1 28.94 x 13.20 x 14.10 CFW700E0125T5NBN1C3 16,742
150 122 Optional 150 100 E 143.3 NEMA 1 28.94 x 13.20 x 14.10 CFW700E0150T5NBN1C3 21,506
CFW 700 - Table of Products
50 E 143.3 NEMA 1 28.94 x 13.20 x 14.10 CFW700E63P0T5NBN1C3 10,676
60 E 143.3 NEMA 1 28.94 x 13.20 x 14.10 CFW700E80P0T5NBN1C3 11,306
75 E 143.3 NEMA 1 28.94 x 13.20 x 14.10 CFW700E0107T5NBN1C3 13,604
100 E 143.3 NEMA 1 28.94 x 13.20 x 14.10 CFW700E0125T5NBN1C3 16,742
100 E 143.3 NEMA 1 28.94 x 13.20 x 14.10 CFW700E0150T5NBN1C3 21,506
Notes: The maximum motor power ratings listed above are based on WEG 2 and 4 pole motors. For motors with different numbers of poles
(ie. 6 and 8 poles), other voltages and/or from other manufacturers, specify the VFD through the motor rated current.
* ND - Normal Duty
• 110% during 60 seconds every 10 minutes
• 150% during 3 seconds every 10 minutes
* HD - Heavy Duty
• 150% during 60 seconds every 10 minutes
• 200% during 3 seconds every 10 minutes
101
Variable Frequency Drives1.40
www.pamensky.com
CFW 700 - AccessoriesCommunication
Description Part Number List Price
CAN Interface Module (CANopen and DeviceNet) CAN-01 $378
Profi bus DP-V1 Interface modul PROFIBUS DP-01 512
Keypad Accessories and Cable for HMI
Description Part Number List Price
CFW 700 Keypad HMI-02 $233
Frame for keypad remote assembly, IP56 RHMIF-02 52
Blank cover for keypad slot HMID-01 47
1m (3.3ft) Remote Keypad Cable IHM CAB-RS-1M 47
2m (6.6ft) Remote Keypad Cable IHM CAB-RS-2M 52
3m (10ft) Remote Keypad Cable IHM CAB-RS-3M 57
5m (16ft) Remote Keypad Cable IHM CAB-RS-5M 65
7.5m (25ft) Remote Keypad Cable IHM CAB-RS-7.5M 78
10m (33ft) Remote Keypad Cable IHM CAB-RS-10M 88
Shielding Kits
Description Part Number List Price
Power cable shielding kit for frame A PCSA-01 $42
Power cable shielding kit for frame B PCSB-01 44
Power cable shielding kit for frame C PCSC-01 47
NEMA 1 Kits
Description Part Number List Price
NEMA 1 - conduit kit kit for frame A + Power cable shielding KN1A-02 $109
NEMA 1 - conduit kit kit for frame B + Power cable shielding KN1B-02 109
NEMA 1 - conduit kit kit for frame C + Power cable shielding KN1C-02 124
101
1.41Variable Frequency Drives
www.pamensky.com
CFW 700 - Technical Data
Voltage and rating
features
Voltage
Single-phase 200-220 V ac (+10%-15%)
Three-phase
200-220 V ac (+10%-15%)
380-480 V ac (+10%-15%)
500-600 V ac (+10%-15%)
Power
Single-phase 1.5 to 3 HP (1.1 to 2.2 kW)
Three-phase
1.5 to 75 HP (1.1 to 55 kW)
2 to 150 HP (1.5 to 110 kW)
2 to 175 HP (1.5 to 110 kW)
Frequency 50...60 Hz (+/-2%_48 to 63 Hz)
Displacement factor Greater than 0.98
Effi ciency Greater than 0.97
Power factor0.94 for Three-phase input at nominal conditional
0.70 for Single-phase input at nominal conditional
Control
Frequency range0 to 3.4x motor rated frequency (P0403). The rated frequency is programable up to 300Hz (V/Hz) and
120Hz (vector mode). Switching Frequency data must be observed for speed limits.
Switching
frequency
Standard: 5 kHz (A, B, C e D frames)
2.5 kHz for all 380 V models frame E
2.5 kHz for frame E 220 V models 142/180 Amps (ND)
2.5 kHz for frame E 220 V model 211 Amps (ND/HD)
5 kHz for frame E 220 V models 142/180 Amps (HD)
Available options for 2.5/5/10 kHz (check for derating)
Overload
Normal Duty (ND)110% for 1 min every 10 min
150% for 3 s every 10 min
Heavy Duty (HD)150% for 1 min every 10 min
200% for 3 s every 10 min
Aceleration 0 to 999 s
Deceleration 0 to 999 s
Environment
Temperature
-10 to 50 °C (14 to 122 °F) for most of models. For operating temperature of each model the table "Dimensions, Weight and
Temperature”shall be checked.
-10...60ºC for frames A, B, C and D (up to 45 °C without derating for models 13 A and 24 A/200...240 V, 7 and 10 A/380...480 V and up to
50 °C without derating for the other models) and-10...55 °C for frame E (up to 45 °C without derating). If derating has to be considered have
2% current reduction for each °C above the specifi c operating temperature.
Humidity 5 to 90% with no condensation
Altitude0 to 1000 meters with no derating
Up to 4000 meters with current reduction of 1% for each 100 meters above 1000 meters
Braking Methods
Dynamic brakingAvailable as standard for frame sizes A, B, C and D for 460 V and D for 600 V. For frame size E "DB”models has to be used. An extra resistor
must be fi tted in for dynamic braking capability.
Optimal braking There is no need for braking resistor
DC braking DC current applied to motor
Performance
V/f
Speed control
Regulation: 1% of rated speed
Speed Variation range 1:20
Voltage vector VVWRegulation: 1% of rated speed
Speed Variation range 1:30
Sensorless vector Regulation: 0.5% of rated speed
Vector with encoder
(Encoder interface
built-in)
Speed Variation range 1:100
Regulation:+/- 0.1% of rated speed with digital reference
(keypad, serial fi eldbus, multispeed)
Regulation:+/- 0.2% of rated speed with 12 bits analog input
Torque control
Range: 10 to 180%
Regulation: +/-5% of rated torque
Sensorless VectorRange: 20 to 180%
Regulation: +/-10% of rated torque (above 3 Hz)%
I/Os
Inputs
Digital 8 x isolated bidirectional 24 V
Analog2 x +/-10 V, 11 bits + signal (differencial) or 0/4...20 mA, 11 bits (differencial)
Impedance: 400 kΩ for voltage signal / 500 Ω for current signal
OutputRelay
1 x relay NO/NC contact (240 V ac/1 A)
4 x open drain (24 V/200 mA)
Analog 2 x 0...10 V or 0/4...20 mA, 11 bits
24 V power supply
capacity500 mA (available for the user, including I/Os)
101
Variable Frequency Drives1.42
www.pamensky.com
CFW 700 - Technical Data
Communication
Modbus-RTURS485 built-in (available at the control terminals)
RS485 built-in / Superdrive and WLP communication
DeviceNet CAN-01 (slot 3)
CANopen CAN-01 (slot 3)
Profi bus DP PROFIBUS DP-01 (slot 3)
Safety standards
UL 508C Power conversion equipment
UL 840 Insulation coordination including clearences and creepage distances for electrical equipment
EN61800-5-1 - Safety requirements electrical, thermal and energy.
EN 50178 - Electronic equipment for use in power installations.
EN 60204-1 - Safety of machinery. Electrical equipment of machines. Part 1: General requirements. In order to have a machine in conformity with this regulation,
the machine builder is resposible forthe installation of na emergency shutdown device and na equipment for power disconnection.
EN 60146 (IEC 146) - Semiconductor converters.
EN 61800-2 - Adjustable speed electrical power drive systems - Part 2: General requirements - Rating specifi cations for low voltage adjustable frequency
A.C. power drive systems
Mechanical
construction
standards
eletromagnetic
compatibility
standards (EMC)
EN 60529 - Degrees of protection provided by enclosures (IP code).
UL 50 - Enclosures for electrical equipment
EN 61800-3 - Adjustable speed electrical power drive systems - Part 3: EMC product standard including specifc test methods.
EN 55011 - Limits and methods of measurement of radio disturbance characteristics of undustrial, scientifi c and medical (ISM) radio-frequency equipment.
CISPR 11 - Industrial, scientifc and medical (ISM) radio-frequency equipment - Eletromagnetic disturbance characteristics
- Limits and methods of measurement.
EN 61000-4-2 - Electromagnetic compatibility (EMC) - Part 4: Testing and measurement techniques - Section 2: Eletrostatic
discharge immunity test.
EN 61000-4-3 - Electromagnetic compatibility (EMC) - Part 4: Testing and measurement techniques - Section 3: Radiated, radio-
frequency, electromagnetic feld immunity test.
EN 61000-4-4 - Electromagnetic compatibility (EMC) - Part 4: Testing and measurement techniques - Section 4: Electrical fast
transient/burst immunity test.
EN 61000-4-5 - Electromagnetic compatibility (EMC) - Part 4: Testing and measurement techniques - Section 5: Surge immunity test.
EN 61000-4-6 - Electromagnetic compatibility (EMC)- Part 4: Testing and measurement techniques - Section 6: Immunity to conducted
disturbances, induced by radio-frequency fi elds.
Protections
Overcurrent / Short Circuit
Under / Overvoltage in the power section
Phase Loss
VSD thermal Overload (IGBTs, rectifi er and in the eletronics)
Motor thermal overload
Braking resistor overload
IGBTs overload
Motor overload
Fault / external alarm
CPU failure
Phase-to ground short circuit at the output
Failure at the heatsink fan
Motor overspeed
Wrong connection of encoder wiring
101
1.43Variable Frequency Drives
www.pamensky.com
CFW 701 - HVAC Variable Frequency Drive
Standard Features
• 230 V single-phase
Rated output current 6 to 10 A (1,5 to 3
HP - 1.5 to 3 kW)
• 220 V three-phase
Rated output current of 7 to 211 A (0.5 to
75 HP - 0.18 to 55 kW)
• 380-480 V three-phase
Rated output current of 3.6 to 211 A (0.5
to 150 HP - 0.58 to 110 kW)
• Compact structure, ideal for installation in
confi ned spaces
• High accuracy and reliability in speed
control
• Robust hardware
• Degree of protection IP20 - standard
(IP21 and NEMA1 optional)
• RFI fi lter( for electromagnetic interference
mitigation)
• LCD Operating interface with backlight
• Inductors in the DC Link
• Inputs and outputs (I/O):
8 Isolated digital inputs
3 Differential analog inputs (0-10V/4-20
mA (2) and 4-20 mA (1))
5 Digital outputs (2 relays with NA
contacts, 3 isolated transistors)
2 Non-isolated analog outputs
1 Dedicated input for PTC
• Special varnish protects electronic boards
from dust, moisture, high temperatures
and chemicals According to DIN EN
60068-2-60
• RS-485 interface: BACnet MS/TP,
Metasys N2 and Modbus RTU
• Intelligent cooling system
Optional Features
• Operator interface for remote assembly
(up to 10 meters)
• Flash memory module (storage capacity
of 1 MB)
• Safety stop module – Guarantees the
blocking of fi ring circuit and therefore
power to the motor. Meets EN 954-1 / EN
13849-1, category 3 standards.
This VFD complies with the following standards:
• EN 61800-5-2:2007, EN ISO 13849-
1:2008 + AC:2009, IEC 62061:2005, IEC
61508 Parts 1-7:2010, EN 50178:1997,
IEC 60204-1:2005 (in extracts)
The CFW701 HVAC is a variable-speed drive intended for use
with asynchronous motors when heating, ventilation, air
conditioning and refrigeration applications are to be met.
Offering excellent cost-effectiveness, the CFW701 HVAC follows
the CFW700 with plug and play technology, accessories
incorporated in the standard version and simple operation.
101
Variable Frequency Drives1.44
www.pamensky.com
CFW 701 - Part Number Specifi cation
1 32 654 7 8 9 10
-- Y1 W120DB4TA 03P6CFW701
1. CFW-701 HVAC Variable Frequency Drive
2. Frame Size: A, B, C, D or E
3. Output Rated Current: 200-240V 380-480V
06P0 = 6.0 A 03P6 = 3.6 A
07P0 = 7.0 A 05P0 = 5.0 A
10P0 = 10 A 06P0 = 6 A
13P0 = 13 A 07P0 = 7.0 A
16P0 = 16 A 10P0 = 10 A
24P0 = 24 A 13P5 = 13.5 A
28P0 = 28 A 17P0 = 17 A
33P5 = 33.5 A 24P0 = 24 A
45P0 = 45 A 31P0 = 31 A
54P0 = 54 A 38P0 = 38 A
70P0 = 70 A 45P0 = 45 A
86P0 = 86 A 58P5 = 58.5 A
0105 = 105 A 70P5 = 70.5 A
0142 = 142 A 88P0 = 88 A
0180 = 180 A 0105 = 105 A
0211 = 211 A 0142 = 142 A
0180 = 180 A
0211 = 211 A
* Selection Table for 2
4. Power Supply: S = single-phase
T = three-phase
B = single-phase or three-phase
5. Power Supply Voltage: 2 = 200-240 V (Frames A, B, C, D)
220-230 V (Frame E)
4 = 380-480 V
6. Braking Module: NB = no built-in IGBT
DB = with built-in braking IGBT (standard for frames
A, B, C, D)
7. Enclosure: 20 = IP 20 (standard for frames A, B, C and E)
N1 = Nema 1 (standard for frame D)
21 = IP21 (not available for frame E)
8. RFI Filter: Blank = standard
9. Safety Stop: Blank = standard (without safety stop function)
Y1 = with safety stop function according to
EN-954-1 category 3
10. External Electronic Supply for Control:
Blank = Control circuit is fed by the inverter SMPS
W1 = Control circuit is supplied from an external +24Vdc
Example: CFW701B28POT2DB20
101
1.45Variable Frequency Drives
www.pamensky.com
CFW 701 - Table of Products
Notes: The maximum motor power ratings listed above are based on WEG 2 and 4 pole motors. For motors with different numbers of poles (ie. 6 and 8 poles), other voltages and/
or from other manufacturers, specify the VFD through the motor rated current.
200-240V - Single Phase
Electrical Data Mechanical Data Purchasing Data
Current
(A)
Built-In Dynamic
Braking
Maximum
Applicable Motor FrameWeight
(lb)
Degree of
Protection
Dimensions
(in)
H x W x D
Part Number
HP
6 Standard 1.5 A 13.9 NEMA 1 12.02 x 5.71 x 8.94 CFW701A06POS2DB20
7 Standard 2 A 13.9 NEMA 1 12.02 x 5.71 x 8.94 CFW701A07POS2DB20
10 Standard 3 A 13.9 NEMA 1 12.02 x 5.71 x 8.94 CFW701A10POS2DB20
200-240V - Single and Three Phase
Electrical Data Mechanical Data Purchasing Data
Current
(A)
Built-In Dynamic
Braking
Maximum
Applicable Motor FrameWeight
(lb)
Degree of
Protection
Dimensions
(in)
H x W x D
Part Number
HP
6 Standard 1.5 A 13.9 NEMA 1 12.02 x 5.71 x 8.94 CFW701A06POB2DB20
7 Standard 2 A 13.9 NEMA 1 12.02 x 5.71 x 8.94 CFW701A07POB2DB20
200-240V - Three Phase
Electrical Data Mechanical Data Purchasing Data
Current
(A)
Built-In Dynamic
Braking
Maximum
Applicable Motor FrameWeight
(lb)
Degree of
Protection
Dimensions
(in)
H x W x D
Part Number
HP
7 Standard 2 A 13.9 NEMA 1 12.02 x 5.71 x 8.94 CFW701A07POT2DB20
10 Standard 3 A 13.9 NEMA 1 12.02 x 5.71 x 8.94 CFW701A10POT2DB20
13 Standard 3 A 13.9 NEMA 1 12.02 x 5.71 x 8.94 CFW701A13POT2DB20
16 Standard 5 A 13.9 NEMA 1 12.02 x 5.71 x 8.94 CFW701A16POT2DB20
24 Standard 7.5 B 22.9 NEMA 1 13.82 x 7.46 x 8.94 CFW701B24POT2DB20
28 Standard 10 B 22.9 NEMA 1 13.82 x 7.46 x 8.94 CFW701B28POT2DB20
33.5 Standard 10 B 22.9 NEMA 1 13.82 x 7.46 x 8.94 CFW701B33POT2DB20
45 Standard 15 C 45.2 NEMA 1 17.64 x 8.67 x 11.52 CFW701C45POT2DB20
54 Standard 20 C 45.2 NEMA 1 17.64 x 8.67 x 11.52 CFW701C54POT2DB20
70 Standard 25 C 45.2 NEMA 1 17.64 x 8.67 x 11.52 CFW701C70POT2DB20
86 Standard 30 D 71.8 NEMA 1 21.63 x 11.81 x 12.00 CFW701D86POT2DB20
105 Standard 40 D 71.8 NEMA 1 21.63 x 11.81 x 12.00 CFW701D0105POT2DB20
220-230V - Three Phase
Electrical Data Mechanical Data Purchasing Data
Current
(A)
Built-In Dynamic
Braking
Maximum
Applicable Motor FrameWeight
(lb)
Degree of
Protection
Dimensions
(in)
H x W x D
Part Number
HP
142 Optional 50 E 143.3 NEMA 1 28.94 x 13.20 x 14.10 CFW701E0142POT2NB20
180 Optional 60 E 143.3 NEMA 1 32.63 x 13.20 x 14.10 CFW701E0180POT2NB20
211 Optional 75 E 143.3 NEMA 1 32.63 x 13.20 x 14.10 CFW701E0211POT2NB20
* ND - Normal Duty
• 110% during 60 seconds every 10 minutes
101
Variable Frequency Drives1.46
www.pamensky.com
CFW 701 - Table of Products380-480V - Three Phase
Electrical Data Mechanical Data Purchasing Data
Current
(A)
Built-In Dynamic
Braking
Maximum
Applicable Motor FrameWeight
(lb)
Degree of
Protection
Dimensions
(in)
H x W x D
Part Number
HP
3.6 Standard 2 A 13.9 NEMA 1 12.02 x 5.71 x 8.94 CFW701A03P6T4DB20
5 Standard 3 A 13.9 NEMA 1 12.02 x 5.71 x 8.94 CFW701A05P0T4DB20
7 Standard 3 A 13.9 NEMA 1 12.02 x 5.71 x 8.94 CFW701A07P0T4DB20
10 Standard 5 A 13.9 NEMA 1 12.02 x 5.71 x 8.94 CFW701A10P0T4DB20
13.5 Standard 7.5 A 13.9 NEMA 1 12.02 x 5.71 x 8.94 CFW701A13P5T4DB20
17 Standard 10 B 22.9 NEMA 1 13.82 x 7.46 x 8.94 CFW701B17P0T4DB20
24 Standard 15 B 22.9 NEMA 1 13.82 x 7.46 x 8.94 CFW701B24P0T4DB20
31 Standard 20 B 22.9 NEMA 1 13.82 x 7.46 x 8.94 CFW701B31P0T4DB20
38 Standard 25 C 45.2 NEMA 1 17.64 x 8.67 x 11.52 CFW701C38P0T4DB20
45 Standard 30 C 45.2 NEMA 1 17.64 x 8.67 x 11.52 CFW701C45P0T4DB20
58.5 Standard 40 C 45.2 NEMA 1 17.64 x 8.67 x 11.52 CFW701C58P5T4DB20
70.5 Standard 50 D 71.8 NEMA 1 21.63 x 11.81 x 12.00 CFW701D70P5T4DB20
88 Standard 60 D 71.8 NEMA 1 21.63 x 11.81 x 12.00 CFW701D88P0T4DB20
105 Optional 75 E 143.3 NEMA 1 28.94 x 13.20 x 14.10 CFW701E0105T4NB20
142 Optional 100 E 143.3 NEMA 1 28.94 x 13.20 x 14.10 CFW701E0142T4NB20
180 Optional 150 E 143.3 NEMA 1 32.63 x 13.20 x 14.10 CFW701E0180T4NB20
211 Optional 150 E 143.3 NEMA 1 32.63 x 13.20 x 14.10 CFW701E0211T4NB20
500-600V - Three Phase
Electrical Data Mechanical Data Purchasing Data
Current
(A)
Built-In Dynamic
Braking
Maximum
Applicable Motor FrameWeight
(lb)
Degree of
Protection
Dimensions
(in)
H x W x D
Part Number
HP
2.9 Standard 2 B 22.9 NEMA 1 13.82 x 7.46 x 8.94 CFW701B02P9T5DB20
4.2 Standard 3 B 22.9 NEMA 1 13.82 x 7.46 x 8.94 CFW701B04P2T5DB20
7 Standard 5 B 22.9 NEMA 1 13.82 x 7.46 x 8.94 CFW701B07P0T5DB20
10 Standard 7.5 B 22.9 NEMA 1 13.82 x 7.46 x 8.94 CFW701B10P0T5DB20
12 Standard 10 B 22.9 NEMA 1 13.82 x 7.46 x 8.94 CFW701B12P0T5DB20
17 Standard 15 B 22.9 NEMA 1 13.82 x 7.46 x 8.94 CFW701B17P0T5DB20
22 Optional 20 D 71.8 NEMA 1 21.63 x 11.81 x 12.00 CFW701D22P0T5NB20
27 Optional 25 D 71.8 NEMA 1 21.63 x 11.81 x 12.00 CFW701D27P0T5NB20
32 Optional 30 D 71.8 NEMA 1 21.63 x 11.81 x 12.00 CFW701D32P0T5NB20
44 Optional 40 D 71.8 NEMA 1 21.63 x 11.81 x 12.00 CFW701D44P0T5NB20
53 Optional 50 E 143.3 NEMA 1 32.63 x 13.20 x 14.10 CFW701E53P0T5NB20
63 Optional 60 E 143.3 NEMA 1 32.63 x 13.20 x 14.10 CFW701E63P0T5NB20
80 Optional 75 E 143.3 NEMA 1 32.63 x 13.20 x 14.10 CFW701E80P0T5NB20
107 Optional 100 E 143.3 NEMA 1 32.63 x 13.20 x 14.10 CFW701E0107T5NB20
125 Optional 125 E 143.3 NEMA 1 32.63 x 13.20 x 14.10 CFW701E0125T5NB20
150 Optional 150 E 143.3 NEMA 1 32.63 x 13.20 x 14.10 CFW701E0150T5NB20
211 Optional 150 E 143.3 NEMA 1 32.63 x 13.20 x 14.10 CFW701E0211T4NB20
Notes: The maximum motor power ratings listed above are based on WEG 2 and 4 pole motors. For motors with different numbers of poles (ie. 6 and 8 poles), other voltages and/
or from other manufacturers, specify the VFD through the motor rated current.
* ND - Normal Duty
• 110% during 60 seconds every 10 minutes
101
1.47Variable Frequency Drives
www.pamensky.com
CFW 701 - AccessoriesCommunication
Description Part Number
CAN Interface Module (CANopen and DeviceNet) CAN-01
Profi bus DP-V1 Interface modul PROFIBUS DP-01
Keypad Accessories and Cable for HMI
Description Part Number
CFW 700 Keypad HMI-03
Frame for keypad remote assembly, IP56 RHMIF-03
Blank cover for keypad slot HMID-01
1m (3.3ft) Remote Keypad Cable IHM CAB-RS-1M
2m (6.6ft) Remote Keypad Cable IHM CAB-RS-2M
3m (10ft) Remote Keypad Cable IHM CAB-RS-3M
5m (16ft) Remote Keypad Cable IHM CAB-RS-5M
7.5m (25ft) Remote Keypad Cable IHM CAB-RS-7.5M
10m (33ft) Remote Keypad Cable IHM CAB-RS-10M
Shielding Kits
Description Part Number
Power cable shielding kit for frame A PCSA-01
Power cable shielding kit for frame B PCSB-01
Power cable shielding kit for frame C PCSC-01
NEMA 1 Kits
Description Part Number
NEMA 1 - conduit kit kit for frame A + Power cable shielding KN1A-02
NEMA 1 - conduit kit kit for frame B + Power cable shielding KN1B-02
NEMA 1 - conduit kit kit for frame C + Power cable shielding KN1C-02
101
Variable Frequency Drives1.48
www.pamensky.com
Voltage and rating
features
Voltage
Single phase 200-220 V ac (+10 %-15 %)
Three phase
200-220 V ac (+10 %-15 %)
380-480 V ac (+10 %-15 %)
500-600 V ac (+10%-15%)
Power
Single phase 1.5 to 3 HP (1.1 to 2.2 kW)
Three phase1.5 to 75 HP (1.1 to 55 kW)
2 to 150 HP (1.5 to 110 kW)
Frequency 50...60 Hz (+/-2%_48 to 63 Hz)
Displacement
factorGreater than 0.98
Effi ciency Greater than 0.97
Power factor0.94 for three phase input at nominal conditional
0.70 for single phase input at nominal conditional
Control
Frequency range0 to 3.4x motor rated frequency (P0403). The rated frequency is programable up to 300 Hz (V/Hz) and
120 Hz (vector mode). Switching Frequency data must be observed for speed limits.
Switching
frequency
Standard: 5 kHz ( A, B, C D frames)
2.5 kHz for all 380 V models frame E
2.5 kHz for frame E 220 V models 142/180 Amps (ND)
2.5 kHz for frame E 220 V model 211 Amps (ND/HD)
5 kHz for frame E 220 V models 142/180 Amps (HD)
Available options for 2.5 / 5 / 10 kHz ( check for derating)
Overload
Normal Duty
(ND)110% for 1min every 10 min
Aceleration 0 to 999 s
Deceleration 0 to 999 s
Environment
Temperature
-10 to 50 °C (14 to 122 °F) for most of models. For operating temperature of each model the table " Dimensions,
Weight and Temperature" shall be checked.-10...60ºC for frames A, B, C and D (up to 45 °C without derating for models 13 A and 24 A/200...240 V, 7 and
10 A/380...480 V and up to 50 °C without derating for the other models) and-10...55 °C for frame E (up to 45 °C
without derating). If derating has to be considered have 2% current reduction for each °C above the specifi c operating
temperature.
Humidity 5 to 90% with no condensation
Altitude0 to 1000 meters with no derating
Up to 4000 meters with current reduction of 1% for each 100 meters above 1000 meters
Braking methods
Dynamic brakingAvailable as standard for frame sizes A, B, C and D for 460 V and D for 600 V. For frame size E "DB" models has to be
used. An extra resistor must be fi tted in for dynamic braking capability.
Optimal braking There is no need for braking resistor
DC braking DC Current applied to motor
Performance
V/f
Speed control
Regulation: 1% of rated speed
Speed Variation range 1:20
Voltage Vector
VVW
Regulation: 1% of rated speed
Speed Variation range 1:30
I/Os
Inputs
Digital 8 x isolated bidirectional 24 V
Analog2 x +/-10V, 11 bits + signal (differencial) or 0/4...20 mA, 11 bits (differencial)
Impedance: 400 kΩ for voltage signal / 500Ω for current signal
Output
Relay2 x relay NO/NC contact (240 V ac/1 A)
4 x open drain (24 V/200 mA)
Analog
1 x 0/4 - 20 mA 11bits
2 x 0...10 V or 0/4...20 mA, 11 bits
(not isolated from inverter ground)24 V power
supply capacity500 mA (available for the user, including I/Os)
Communication
Modbus RTU
BACnet MS/TP
Metasys N2
RS485 built-in ( Available in control terminals)
RS485 built-in / Superdrive and WLP communication
CFW 701 - Technical Data
101
1.49Variable Frequency Drives
www.pamensky.com
Safety standards
UL 508C Power conversion equipment
UL 840 Insulation coordination including clearences and creepage distances for electrical equipment
EN61800-5-1 - Safety requirements electrical, thermal and energy.
EN 50178 - Electronic equipment for use in power installations.
EN 60204-1 - Safety of machinery. Electrical equipment of machines. Part 1: General requirements. In order to have a machine in
conformity with this regulation, the machine builder is resposible forthe installation of na emergency shutdown device and na equipment for
power disconnection.
EN 60146 (IEC 146) - Semiconductor converters.
EN 61800-2 - Adjustable speed electrical power drive systems - Part 2: General requirements - Rating specifi cations for low voltage
adjustable frequency A.C. power drive systems
Mechanical
Construccion
Standards
Eletromagnetic
Compatibility
Standards (EMC)
EN 60529 - Degrees of protection provided by enclosures (IP code).
UL 50 - Enclosures for electrical equipment
EN 61800-3 - Adjustable speed electrical power drive systems - Part 3: EMC product standard including specifc test methods.
EN 55011 - Limits and methods of measurement of radio disturbance characteristics of undustrial, scientifi c and medical (ISM) radio-
frequency equipment.CISPR 11 - Industrial, scientifc and medical (ISM) radio-frequency equipment - Eletromagnetic disturbance characteristics - Limits and
methods of measurement.EN 61000-4-2 - Electromagnetic compatibility (EMC) - Part 4: Testing and measurement techniques - Section 2: Eletrostatic discharge
immunity test.EN 61000-4-3 - Electromagnetic compatibility (EMC) - Part 4: Testing and measurement techniques - Section 3: Radiated, radio-frequency,
electromagnetic feld immunity test.EN 61000-4-4 - Electromagnetic compatibility (EMC) - Part 4: Testing and measurement techniques - Section 4: Electrical fast transient/
burst immunity test.
EN 61000-4-5 - Electromagnetic compatibility (EMC) - Part 4: Testing and measurement techniques - Section 5: Surge immunity test.
EN 61000-4-6 - Electromagnetic compatibility (EMC)- Part 4: Testing and measurement techniques - Section 6: Immunity to conducted
disturbances, induced by radio-frequency fi elds.
Protections
Overcurrent / Short circuit
Under / Overvoltage in the power section
Phase loss
VSD thermal overload ( IGBTs, rectifi er and in the eletronics)
Motor thermal overload
Braking resistor overload
IGBTs overload
Motor overload
Fault / external alarm
CPU failure
Phase-to ground short circuit at the output
Failure at the heatsink fan
Motor overspeed
Wrong connection of encoder wiring
CFW 701 - Technical Data
coder wiring
101
Variable Frequency Drives1.50
www.pamensky.com
MVW 01- Medium Voltage VFD
WEG is a traditional supplier of solutions in speed variation, manufacturing all the parts of a system:
Input switchgear, transformer(dry-type or oil-type), frequency inverter and electric motor.
The MVW01 is designed to control medium voltage induction motors. It features unique innovations,
combining hardware robustness with simplicity, reliability and safety in a compact solution with few
components and state-of-the-art technology.
MVW01 follows the same programming
philosophy of the WEG low voltage inverter line,
simplifying its application.
It has a multilevel topology with high-voltage
IGBTs (3.3 or 6.5 kV) and optimal switching
reducing the motor harmonic currents to
extremely low levels. By reducing the number
of components in the drive WEG has made the
MVW-01 more effi cient and reliables.
The multipulse diode confi guration of the input
rectifi er gives a high power factor in the power
supply meeting IEEE 519 requirements.
In the control stage, it has a multiprocessing
architecture using 32-bit processors (64-bit
bus) with fl oating point capability and high
performance, ensuring high effi ciency in motor
control.
Standard Features
• Motor voltage: 2.3 kV, 3.3 kV, 4.16 kV or up
to 6.0 kV - 6.9 kV
• Power ratings up to 8,000 hp (6,000 kW)
• 12-pulse diode input rectifi er (18 or 24
pulses are also available)
• Reduced number of components, which
results in high effi ciency and reliability
• Assembled in IP41/NEMA1 panel
• Multilevel power topology: Neutral Point
Clamped (NPC)
• 3/5 level up to 4160 V
• 5/9 level above 6000 V
• Power and control sections isolated by fi ber
optic cable or optics
• Network communication
• Dry-type plastic fi lm power capacitors of high
reliability and long useful life
• Voltage Source Inverter (VSI)
• Air-cooled
• High effi ciency (> 99%)
• High power factor (> 95%)
• Low noise level (< 75 dBa)
• Low heat dissipation
2300, 6600 & 6900V:
3300 & 4160V:
101
1.51Variable Frequency Drives
www.pamensky.com
MVW 01 - Specifi cation Table2300V - Three Phase
Electrical Data Mechanical Data Purchasing Data
Current
(A)
Maximum Applicable Motor
FrameWeight
(lb)
Degree of
Protection
Dimensions (in)
H x W x DPart NumberConstant Torque Variable Torque
CT VT HP KW HP KW
120 137 500 400 600 450 A 3,432 IP41 86.22 x 94.49 x 37.80 MVW010120T2300ESZ
140 160 600 450 700 500 A 3,432 IP41 86.22 x 94.49 x 37.80 MVW010140T2300ESZ
165 175 700 500 750 560 A 3,432 IP41 86.22 x 94.49 x 37.80 MVW010165T2300ESZ
175 200 750 560 900 710 A 3,432 IP41 86.22 x 94.49 x 37.80 MVW010175T2300ESZ
210 240 900 710 1000 750 A 3,432 IP41 86.22 x 94.49 x 37.80 MVW010210T2300ESZ
250 280 1000 800 1250 900 A 3,432 IP41 86.22 x 94.49 x 37.80 MVW010250T2300ESZ
280 320 1250 900 1500 1120 B 3,740 IP41 86.22 x 102.36 x 37.80 MVW010280T2300ESZ
386 440 1750 1250 2000 1400 B 3,740 IP41 86.22 x 102.36 x 37.80 MVW010386T2300ESZ
450 490 2000 1400 2250 1600 B 3,740 IP41 86.22 x 102.36 x 37.80 MVW010450T2300ESZ
490 560 2250 1600 2500 1600 B 3,740 IP41 86.22 x 102.36 x 37.80 MVW010490T2300ESZ
560 640 2500 1800 3000 2200 B 3,740 IP41 86.22 x 102.36 x 37.80 MVW010560T2300ESZ
730 835 3000 2200 3500 2500 C 5,940 IP41 86.22 x 157.48 x 37.80 MVW010730T2300ESZ
855 930 3700 2800 4000 3000 C 5,940 IP41 86.22 x 157.48 x 37.80 MVW010855T2300ESZ
930 1064 4000 3000 4500 3400 C 5,940 IP41 86.22 x 157.48 x 37.80 MVW010930T2300ESZ
1064 1216 4500 3400 5000 3700 C 5,940 IP41 86.22 x 157.48 x 37.80 MVW011064T2300ESZ
3300V - Three Phase
Electrical Data Mechanical Data Purchasing Data
Current
(A)
Maximum Applicable Motor
FrameWeight
(lb)
Degree of
Protection
Dimensions (in)
H x W x DPart NumberConstant Torque Variable Torque
CT VT HP KW HP KW
85 97 500 400 600 450 A 3,432 IP41 86.22 x 94.49 x 37.80 MVW010085T3300ESZ
100 112 600 450 700 500 A 3,432 IP41 86.22 x 94.49 x 37.80 MVW010100T3300ESZ
112 128 700 500 800 630 A 3,432 IP41 86.22 x 94.49 x 37.80 MVW010112T3300ESZ
138 150 800 630 900 710 A 3,432 IP41 86.22 x 94.49 x 37.80 MVW010138T3300ESZ
150 160 900 710 1000 800 A 3,432 IP41 86.22 x 94.49 x 37.80 MVW010150T3300ESZ
160 182 1000 800 1250 900 A 3,432 IP41 86.22 x 94.49 x 37.80 MVW010160T3300ESZ
186 212 1250 900 1500 1120 A 3,432 IP41 86.22 x 94.49 x 37.80 MVW010186T3300ESZ
235 265 1500 1120 1750 1250 A 3,432 IP41 86.22 x 94.49 x 37.80 MVW010235T3300ESZ
265 312 1750 1250 2000 1400 A 3,432 IP41 86.22 x 94.49 x 37.80 MVW010265T3300ESZ
310 354 2000 1400 2250 1600 A 3,432 IP41 86.22 x 94.49 x 37.80 MVW010310T3300ESZ
375 428 2500 1800 2750 2000 C 5,940 IP41 86.22 x 157.48 x 37.80 MVW010375T3300ESZ
500 571 3000 2200 3750 2800 C 5,940 IP41 86.22 x 157.48 x 37.80 MVW010500T3300ESZ
580 650 3750 2800 4000 3000 C 5,940 IP41 86.22 x 157.48 x 37.80 MVW010580T3300ESZ
670 755 4000 3000 4500 3300 D 9,900 IP41 87.52 x 233.07 x 39.57 MVW010670T3300ESZ
880 1008 5500 4100 6000 4500 D 9,900 IP41 87.52 x 233.07 x 39.57 MVW010880T3300ESZ
1178 1235 7000 5225 8000 6000 E 11,000 IP41 87.52 x 283.46 x 39.57 MVW011178T3300ESZ
4160V - Three Phase
Electrical Data Mechanical Data Purchasing Data
Current
(A)
Maximum Applicable Motor
FrameWeight
(lb)
Degree of
Protection
Dimensions (in)
H x W x DPart NumberConstant Torque Variable Torque
CT VT HP KW HP KW
70 80 500 400 600 450 A 3,432 IP41 86.22 x 94.49 x 37.80 MVW010070T4160ESZ
80 91 600 450 700 500 A 3,432 IP41 86.22 x 94.49 x 37.80 MVW010080T4160ESZ
94 107 700 500 800 630 A 3,432 IP41 86.22 x 94.49 x 37.80 MVW010094T4160ESZ
110 120 800 630 900 710 A 3,432 IP41 86.22 x 94.49 x 37.80 MVW010110T4160ESZ
120 130 900 710 1000 800 A 3,432 IP41 86.22 x 94.49 x 37.80 MVW010120T4160ESZ
130 148 1000 800 1250 900 A 3,432 IP41 86.22 x 94.49 x 37.80 MVW010130T4160ESZ
162 170 1250 900 1350 1000 A 3,432 IP41 86.22 x 94.49 x 37.80 MVW010162T4160ESZ
170 188 1350 1000 1500 1120 A 3,432 IP41 86.22 x 94.49 x 37.80 MVW010170T4160ESZ
188 214 1500 1120 1750 1300 A 3,432 IP41 86.22 x 94.49 x 37.80 MVW010188T4160ESZ
250 286 2000 1400 2250 1600 A 3,432 IP41 86.22 x 94.49 x 37.80 MVW010250T4160ESZ
300 342 2250 1600 2750 2000 C 5,940 IP41 86.22 x 157.48 x 37.80 MVW010300T4160ESZ
357 403 3000 2250 3900 2600 C 5,940 IP41 86.22 x 157.48 x 37.80 MVW010357T4160ESZ
475 542 4000 2900 4500 3300 C 5,940 IP41 86.22 x 157.48 x 37.80 MVW010475T4160ESZ
536 610 4000 2900 5000 3700 D 9,900 IP41 87.52 x 233.07 x 39.57 MVW010536T3300ESZ
712 815 5500 4100 6000 4500 D 9,900 IP41 87.52 x 233.07 x 39.57 MVW010712T4160ESZ
950 1086 7000 5225 8000 6000 E 11,000 IP41 87.52 x 283.46 x 39.57 MVW010950T4160ESZ
101
Variable Frequency Drives1.52
www.pamensky.com
MVW 01 - Specifi cation Table
Notes• Power rating guide, specify the MVW01 through the inverter output rated current• VT= Variable torque – allowable overload of 115% for 60s, every 10 min
6000 to 6300V - Three Phase
Electrical Data Mechanical Data Purchasing Data
Current
(A)
Maximum Applicable Motor
FrameWeight
(lb)
Degree of
Protection
Dimensions (in)
H x W x DPart NumberConstant Torque Variable Torque
CT VT HP KW HP KW
44 58 500 370 600 450 C1 3,740 IP41 90.79 x 70.87 x 47.24 MVW010058T6300ESZ
59 78 600 450 800 600 C1 3,740 IP41 90.79 x 70.87 x 47.24 MVW010078T6300ESZ
79 104 800 600 1000 750 C1 3,740 IP41 90.79 x 70.87 x 47.24 MVW010104T6300ESZ
95 124 900 675 1350 1000 C1 3,740 IP41 90.79 x 70.87 x 47.24 MVW010124T6300ESZ
107 140 1000 750 1500 1120 C1 3,740 IP41 90.79 x 70.87 x 47.24 MVW010140T6300ESZ
127 166 1350 1000 1750 1300 C2 6,820 IP41 87.64 x 137.87 x 39.57 MVW010166T6300ESZ
144 188 1500 1120 2250 1680 C2 6,820 IP41 87.64 x 137.87 x 39.57 MVW010188T6300ESZ
164 214 1750 1300 2500 1865 C2 6,820 IP41 87.64 x 137.87 x 39.57 MVW010214T6300ESZ
199 260 2250 1680 3000 2240 C2 6,820 IP41 87.64 x 137.87 x 39.57 MVW010260T6300ESZ
220 288 2500 1865 3500 2600 C2 6,820 IP41 87.64 x 137.87 x 39.57 MVW010288T6300ESZ
253 330 3000 2240 4000 3000 C3 11,000 IP41 87.52 x 182.68 x 39.57 MVW010330T6300ESZ
322 420 3700 2760 5000 3700 C3 11,000 IP41 87.52 x 182.68 x 39.57 MVW010420T6300ESZ
379 495 4500 3350 6000 4475 C3 11,000 IP41 87.52 x 182.68 x 39.57 MVW010495T6300ESZ
440 575 5000 3700 7000 5225 C3 11,000 IP41 87.52 x 182.68 x 39.57 MVW010575T6300ESZ
6600 to 6900V - Three Phase
Electrical Data Mechanical Data Purchasing Data
Current
(A)
Maximum Applicable Motor
FrameWeight
(lb)
Degree of
Protection
Dimensions (in)
H x W x DPart NumberConstant Torque Variable Torque
CT VT HP KW HP KW
40 53 500 370 600 450 C1 3,740 IP41 90.79 x 70.87 x 47.24 MVW01C0053T6900ESZ
53 70 600 450 800 600 C1 3,740 IP41 90.79 x 70.87 x 47.24 MVW01C0070T6900ESZ
72 94 800 600 1000 750 C1 3,740 IP41 90.79 x 70.87 x 47.24 MVW01C0094T6900ESZ
85 112 1000 750 1350 1000 C1 3,740 IP41 90.79 x 70.87 x 47.24 MVW01C0112T6900ESZ
99 130 1250 900 1500 1120 C1 3,740 IP41 90.79 x 70.87 x 47.24 MVW01C0123T6900ESZ
115 150 1350 1000 2000 1500 C2 6,820 IP41 87.64 x 137.87 x 39.57 MVW010150T6900ESZ
130 170 1500 1120 2250 1680 C2 6,820 IP41 87.64 x 137.87 x 39.57 MVW010170T6900ESZ
144 188 1750 1300 2500 1865 C2 6,820 IP41 87.64 x 137.87 x 39.57 MVW010188T6900ESZ
180 235 2250 1680 3000 2240 C2 6,820 IP41 87.64 x 137.87 x 39.57 MVW010235T6900ESZ
203 265 2500 1865 3500 2600 C2 6,820 IP41 87.64 x 137.87 x 39.57 MVW010265T6900ESZ
230 300 3000 2240 4000 3000 C3 11,000 IP41 87.52 x 182.68 x 39.57 MVW010300T6900ESZ
287 375 3700 2760 5000 3730 C3 11,000 IP41 87.52 x 182.68 x 39.57 MVW010375T6900ESZ
345 450 4500 3350 6000 4475 C3 11,000 IP41 87.52 x 182.68 x 39.57 MVW010450T6900ESZ
398 520 5000 3700 7000 5225 C3 11,000 IP41 87.52 x 182.68 x 39.57 MVW010520T6900ESZ
101
1.53Variable Frequency Drives
www.pamensky.com
MVW 01- Compact Medium Voltage VFD
WEG is a traditional supplier of solutions in speed variation, manufacturing all the parts of a system:
Input switchgear, transformer(dry-type or oil-type), frequency inverter and electric motor.
The MVW01 is designed to control medium voltage induction motors. It features unique innovations,
combining hardware robustness with simplicity, reliability and safety in a compact solution with few
components and state-of-the-art generation technology.
MVW01 follows the same programming
philosophy of the WEG low voltage inverter line,
simplifying its application.
It has a multilevel topology with high-voltage
IGBTs (3.3 or 6.5 kV) and optimal switching
reducing the motor harmonic currents to
extremely low levels. By reducing the number
of components in the drive WEG has made the
MVW-01 more effi cient and reliables.
The multipulse diode confi guration of the input
rectifi er gives a high power factor in the power
supply meeting IEEE 519 requirements.
In the control stage, it has a multiprocessing
architecture using 32-bit processors (64-bit
bus) with fl oating point capability and high
performance, ensuring high effi ciency in motor
control.
Standard Features
• Motor voltage: 2.3 kV, 3.3 kV, 4.16 kV or up
to 6.0 kV - 6.9 kV
• Power ratings up to 8,000 hp (6,000 kW)
• 18-pulse diode input rectifi er standard (12
pulse is also available)
• Reduced number of components, which
results in high effi ciency and reliability
• Assembled in IP41/NEMA1 panel
• Multilevel power topology: Neutral Point
Clamped (NPC)
• 3/5 level up to 4160 V
• 5/9 level above 6000 V
• Power and control sections isolated by fi ber
optic cable or optics
• Network communication
• Dry-type plastic fi lm power capacitors of high
reliability and long useful life
• Voltage Source Inverter (VSI)
• Air-cooled
• High effi ciency (> 99%)
• High power factor (> 95%)
• Low noise level (< 75 dBa)
• Low heat dissipation
101
Variable Frequency Drives1.54
www.pamensky.com
MVW 01 Compact - Specifi cation Table3300V - Three Phase
Electrical Data Mechanical Data Purchasing Data
Current
(A)
Maximum Applicable Motor
FrameWeight
(lb)
Degree of
Protection
Dimensions (in)
H x W x DPart NumberConstant Torque Variable Torque
CT VT HP KW HP KW
85 97 500 375 600 450 A0 1,980 IP41 91.18 x 39.37 x 39.45 MVW01C0085T3300ESZ
100 112 600 450 700 525 A0 1,980 IP41 91.18 x 39.37 x 39.45 MVW01C0100T3300ESZ
112 128 700 525 800 600 A0 1,980 IP41 91.18 x 39.37 x 39.45 MVW01C0112T3300ESZ
125 138 800 600 900 675 AO 1,980 IP41 91.18 x 39.37 x 39.45 MVW01C0125T3300ESZ
4160V - Three Phase
Electrical Data Mechanical Data Purchasing Data
Current
(A)
Maximum Applicable Motor
FrameWeight
(lb)
Degree of
Protection
Dimensions (in)
H x W x DPart NumberConstant Torque Variable Torque
CT VT HP KW HP KW
70 80 500 375 600 450 A0 1,980 IP41 91.18 x 39.37 x 39.45 MVW01C0070T4160ESZ
80 91 600 450 700 525 A0 1,980 IP41 91.18 x 39.37 x 39.45 MVW01C0080T4160ESZ
94 107 700 525 800 600 A0 1,980 IP41 91.18 x 39.37 x 39.45 MVW01C0094T4160ESZ
110 120 800 600 900 675 A0 1,980 IP41 91.18 x 39.37 x 39.45 MVW01C0110T4160ESZ
120 130 900 675 1000 750 A0 1,980 IP41 91.18 x 39.37 x 39.45 MVW01C0120T4160ESZ
Notes• Power rating guide, specify the MVW01 through the inverter output rated current• CT= Constant torque – allowable overload of 150% for¨60s, every 10 min• VT= Variable torque – allowable overload of 115% for 60s, every 10 min
101
1.55Variable Frequency Drives
www.pamensky.com
Main Power Supply
Voltage 2300, 3300, 4160, 6300 or 6900 V (± 10%, -20% with reduced output power)
Frequency 50 or 60 Hz (specify)± 3%
Phase Unbalance <3%
Cos >0,97
Overvoltage category Category III
Auxiliary supply
Voltages 220, 380, 400, 415, 440, 460 , 480, 525, 575, 660 or 690 V
Frequency 50 or 60 Hz, )±3 %
Phase Unbalance <3%
Protection degree Standard IP41
Dimensions Width / Height / Depth (mm) 7 different mechanics (see item 9.4)
Environmental Conditions
Temperature 0 to 40o C (up to 50o C with reduction of 2.5% / oC on the output current)
Humidity 5 to 90% noncondensing
Altitude 0 to 1000 m (up to 4000 m with reduction of 10% / 1000 m)
Pollution degree 2
Finishing Color (Standard)Light Blue cod. 14040 (Doors)
Dark Blue cod 42350 (Base, roof, shutters)
Control
Microprocessor 32 bits
Control Method PWM sinusoidal SVM (Space Vector Modulation) and optimal pulse patterns (OPP)
Control Types Scalar (Imposed voltage - V/F), sensorless vector and closed loop vector
Switching Device High voltage IGBT (HV – IGBT)
Frequency variation 0 to 100 Hz
Overload capacity150 % for 60 seconds, every 10 min. (1.5 x I rated. – CT)
115 % for 60 seconds, every 10 min. (1.15 x I rated – VT)
Effi ciency 99%
Performance Speed Control
V / FRegulation 1 % of rated speed with slip compensation
Resolution: 1 rpm (keypad reference)
SensorlessSpeed regulation: 0.5% of rated speed
Speed variation range:1:100
With Encoder (Use EBA
or EBB card)
Regulation:
± 0.1% of rated speed with analog input of 14 bits (EBA);
± 0.1% of rated spedd wth digital reference (keyboard, serial, Fieldbus,
Electronic Potetionmeter, multispeed);
± 0.1% of rated speed with analog input of 10 bits (CC9)
Inputs
Analog
2 Programmable differential inputs ( 10 bits ): 0 to 10 V, 0 to 20 mA ou 4 to 20 mA
1 Programmable bipolar input ( 14 bits ): -10 to + 10 V, 0 to 20 mA or 4...20 mA 1)
1 Programmable isolated input ( 10 bits ): 0 to 10 V, 0 a 20 mA or 4 to 20 mA 1)
1 Programmable isolated input ( 10 bits ): 0 to 10 V, 0 a 20 mA or 4 to 20 mA
Digital
8 Programmable isolated inputs: 24 Vdc
1 Programmable isolated input: 24 Vdc 1)
1 Programmable isolated input: 24 Vdc ( for motor PTC thermistor) 1)
Outputs
Analog
2 Programmable outputs ( 11 bits ) : 0 to 10 V
2 Programmable bipolar outputs ( 14 bits ) : (-10 to + 10) V1)
2 Programmable isolated outputs ( 11 bits ) : 0 to 20 mA or 4 to 20 mA 1)
2 Programmable isolated outputs ( 11 bits ) : 0 to 20 mA or 4 to 20 mA
Relay 5 Programmable outputs, contacts NA/NF ( NO/NC ) : 240 Vac, 1 A
Transistor 2 DC Programmable isolated outputs: 24 Vdc, 50 mA 1)
Communication
Serial InterfaceRS-232 (point to point)
RS-485, isolated via EBA or EBB cards (multi-point up to 30 inverters) 1)
FieldBus NetworksModbus RTU (embedded software) via serial interface RS-485
Ethernet, Profi bus DP or DeviceNet via additional kits KFB 1)
SafetyProtections
(memories of the last 100 faults/
alarms with date and time)
Overvoltage in the circuit: intermediate Output short-circuit
Undervoltage in the circuit: intermediate Output ground-short-circuit
Overtemperature in the inverter and the motor External fault
Overcurrent in the output Failed self-test and programming
Motor overload (I x t) Failed self-test and programming
Overload in braking resistor Phase fault in power supply
Failed CPU (Watchdog) / EPROM Interface MMI-MVW-01 connection fault
Incremental Encoder fault
1) Optional
MVW 01 - Technical Data
101
Variable Frequency Drives1.56
www.pamensky.com
Compliances /
Standards
Electromagnetic
compatibility
EMC directive 89 / 336 / EEC – industrial environment
CEI Standard - IEC 61800-3 (EMC – Emisson and Immunity)
CEI - IEC 61800
Adjustable Speed Electrical Power Drive System
Part 4 – General Requirements
Part 5 – Safety Requirements
Keypad
Commands
Start / Stop, General Functions Programming
Increase / Decrease Speed
JOG, FWD/VER and Local/Remote
Monitoring
Speed Reference (rpm) Output Current (A)
Motor Speed (rpm) Output Voltage (V)
Speed Proportional Value (Ex: ft/min) Drive Status
Output Frequency (Hz) Status of Digital Inputs
DC Link Voltage (V) Status of Digital Outputs
Motor Torque (%) Status of Relay Outputs
Output Power (kW) Analog Inputs Value
Hours Powered Up (h) 100 Last Faults with Date and Time
Hours Enabled (h) Fault / Alert Messages
Control features
Standard
Keypad with LCD + LED displays
Password to protect drive programming
LCD display language selection: English, Spanish and Portuguese
Fault auto-diagnosis and auto-reset
Parameters reset to factory or user default
Inverter Self-tuning to motor and load (Vector Modes)
Specifi c unit indication (Ex: l/s, t/h, %, etc.)
Slip compensation (V / Hz Mode)
Manual and Automatic Torque Boost – I x R (V / Hz Mode)
Adjustable V / Hz Curve (V / Hz Mode)
Minimum and maximum speed limits
Maximum current limit
Adjustable motor overload protection
Adjustable digital gain and offset for the analog inputs
Adjustable digital gain for the analog outputs
JOG function
JOG + / JOG – Function (momentary speed increase/decrease)
COPY Function (Drive Keypad or Keypad Drive)
Comparison functions for the digital outputs:
N* > Nx; N > Nx; N < Nx ; N = 0; N = N*; Is > Ix ; Is < Ix; T > Tx and T < Tx
Where: N = Motor speed; N* = Speed reference; Is = Output Current and T = Motor torque
Linear and “S type” ramps / double ramp
Independent acceleration and deceleration ramps
Multi-speed function (up to 8 preset speeds)
Special resources (Hour meter and Wattmeter)
Overlapped PID Regulator (for automatic level, fl ow, pressure, and weight control)
Direction of Rotation selection (FWD/REV)
Local / Remote Operation selection
Flying Start function (restart with a spinning load)
Critical Speed Avoidance (Skip Speed)
Ride-Through function (operation during momentary power loss)
Built-in Modbus RTU (needs the RS-232 or RS-485 interface)
Options
NEMA 4 Remote Keypad (LCD display)
Remote Keypad cable (3.3, 6.6, 10, 16, 25 and 35 ft)
Remote Keypad frame kit
Expansion Boards with special functions
Profi bus-DP
DeviceNet
SUPERDRIVE G2 Kit with RS-232 Serial Interface Communication (Drive - PC)
MVW 01 - Technical Data
101
2.1Soft Starters
www.pamensky.com
SSW 05 Plus - Soft Starter
The SSW-05 Plus Micro Soft-Starters, with DSP control (Digital Signal Processor) have been
designed to supply excellent performance during starting and stopping of electric motors with an
excellent cost effectiveness ratio. The Operator Interface allows easy parameter setting, simplifying
the start-up and operation activities. The SSW-05 Plus Micro Soft-Starters are compact, optimizating
space in electrical panels. The SSW-05 Plus already incorporates protection for the driven motor.
Standard Features
• 208 - 460V, 460-575V 50/60Hz input power
supply
• Duty cycle: 300% rated current during 10
seconds, 4 starts per hour
• Built-in bypass contacts
• One digital input for Start/Stop
(90 - 250 Vac)
• One digital input for Fault Reset
(90 - 250 Vac)
• One relay output for Run indication
(1 Amp - 250V)
• One relay output for Full Voltage indication
(1 Amp - 250V)
• RS-232 serial port
• Adjustable acceleration and deceleration
ramps (1 - 20 seconds)
• Adjustable pedestal voltage
(30 - 80% of line voltage)
• Protective features: Motor overload, over
current and locked rotor, SCR overload,
phase loss and phase sequence
• DIN rail or direct mount
• Ambient: 32ºF (0ºC) to 131ºF (55ºC), 3300ft
(1000m) altitude, 90% non-condensing
humidity
Optional Features
• Remote Keypad
• PC Programming Software
101
Soft Starters2.2
www.pamensky.com
SSW-05 - Part Number Specifi cation
9
Z
7
--
8
--
6
P
5
E
4
2246
3
T
2
0010
1
SSW05
1. Soft-Starter line SSW-05
2. Output Rated Current 0003 = 3 A
0010 = 10 A
0016 = 16 A
0023 = 23 A
0030 = 30 A
0045 = 45 A
0060 = 60 A
0085 = 85 A
* Selection Table for 2
3. Power Supply: T = Three-phase
4. Power Supply Voltage: 2246 = 220 ... 460 V
4657 = 460 ... 575 V
5. Language: P = Portuguese
E = English
G = German
S = Spanish
6. Product Version: P = Plus
7. Special Hardware: Blank = Standard (not available)
Hx = Optional version x (H1 ... Hn)
8. Special Software: Blank = Standard (not available)
Sx = Optional version x (S1 ... Sn)
9. End of Part Number: Z
Example: SSW050060T4657PPZ
101
2.3Soft Starters
www.pamensky.com
SSW 05 Plus - Table of Products230-460V - Three Phase
Electrical Data Mechanical Data Purchasing Data
Current
(A)
Maximum Applicable Motor
FrameWeight
(lb)
Degree of
Protection
Dimensions
(in)
H x W x D
Part NumberList
PriceHP Kw Voltage
3 0.75 0.55 230 1 1.63 IP00 5.1 x 2.3 x 5.7 SSW050003T2246EPZ $ 581
10 3 2.2 230 1 1.63 IP00 5.1 x 2.3 x 5.7 SSW050010T2246EPZ 594
16 5 3.7 230 1 1.63 IP00 5.1 x 2.3 x 5.7 SSW050016T2246EPZ 654
23 7.5 5.5 230 1 1.63 IP00 5.1 x 2.3 x 5.7 SSW050023T2246EPZ 705
30 10 7.5 230 1 1.63 IP00 5.1 x 2.3 x 5.7 SSW050030T2246EPZ 757
45 15 11 230 2 3.68 IP00 7.3 x 3.1 x 6.8 SSW050045T2246EPZ 974
60 20 15 230 2 3.68 IP00 7.3 x 3.1 x 6.8 SSW050060T2246EPZ 1,191
85 30 22 230 2 3.68 IP00 7.3 x 3.1 x 6.8 SSW050085T2246EPZ 1,432
230-460V - Three Phase
Electrical Data Mechanical Data Purchasing Data
Current
(A)
Maximum Applicable Motor
FrameWeight
(lb)
Degree of
Protection
Dimensions
(in)
H x W x D
Part NumberList
PriceHP Kw Voltage
3 1.5 1.1 460 1 1.63 IP00 5.1 x 2.3 x 5.7 SSW050003T2246EPZ $ 581
10 5 307 460 1 1.63 IP00 5.1 x 2.3 x 5.7 SSW050010T2246EPZ 594
16 10 7.5 460 1 1.63 IP00 5.1 x 2.3 x 5.7 SSW050016T2246EPZ 654
23 15 11 460 1 1.63 IP00 5.1 x 2.3 x 5.7 SSW050023T2246EPZ 705
30 20 15 460 1 1.63 IP00 5.1 x 2.3 x 5.7 SSW050030T2246EPZ 757
45 30 22 460 2 3.68 IP00 7.3 x 3.1 x 6.8 SSW050045T2246EPZ 974
60 40 30 460 2 3.68 IP00 7.3 x 3.1 x 6.8 SSW050060T2246EPZ 1,191
85 60 45 460 2 3.68 IP00 7.3 x 3.1 x 6.8 SSW050085T2246EPZ 1,432
460-575V - Three Phase
Electrical Data Mechanical Data Purchasing Data
Current
(A)
Maximum Applicable Motor
FrameWeight
(lb)
Degree of
Protection
Dimensions
(in)
H x W x D
Part NumberList
PriceHP Kw Voltage
3 2 1.5 575 1 1.63 IP00 5.1 x 2.3 x 5.7 SSW050003T4657EPZ $ 581
10 7.5 5.5 575 1 1.63 IP00 5.1 x 2.3 x 5.7 SSW050010T4657EPZ 594
16 10 7.5 575 1 1.63 IP00 5.1 x 2.3 x 5.7 SSW050016T4657EPZ 654
23 20 15 575 1 1.63 IP00 5.1 x 2.3 x 5.7 SSW050023T4657EPZ 705
30 25 18.5 575 1 1.63 IP00 5.1 x 2.3 x 5.7 SSW050030T4657EPZ 757
45 40 30 575 2 3.68 IP00 7.3 x 3.1 x 6.8 SSW050045T4657EPZ 974
60 50 37 575 2 3.68 IP00 7.3 x 3.1 x 6.8 SSW050060T4657EPZ 1,191
85 75 55 575 2 3.68 IP00 7.3 x 3.1 x 6.8 SSW050085T4657EPZ 1,432
101
Soft Starters2.4
www.pamensky.com
SSW 05 - AccessoriesAccessories
Keypad and Keypad Cables
Description Part Number List Price
Remote Keypad with LED Display SSW05HMIRS $130
1m (3.3 ft.) Remote Keypad Cable CAB-RS-1 23
2m (6.6 ft.) Remote Keypad Cable CAB-RS-2 31
3m (10 ft.) Remote Keypad Cable CAB-RS-3 42
5m (15 ft.) Remote Keypad Cable CAB-RS-5 52
7.5m (25 ft.) Remote Keypad Cable CAB-RS-7.5 62
10m (33 ft.) Remote Keypad Cable CAB-RS-10 73
SSW 05 - Technical Data
Power Supply
Voltage220 - 460 Vac (+10%, -15%)
460 - 575 Vac (+10%, -15%)
Frequency 50 / 60 Hz
Electronic Supply Switched mode power supply (90 – 250 Vac )
Enclosure Injected Plastic Case IP00
ControlMethod Motor Voltage Variation
CPU DSP type microprocessor
Starting Duty Cycle Standard 300% ( 3 x Inom. ) during 10 s, 4 starts per hour
Inputs Digital1 input for starting and stopping
1 input for error reset
Outputs Digital1 relay output for full voltage indication (By-Pass)
1 relay output for operation indication
Communication Serial Interface RS-232C
Safety Protections
Motor overload
Phase sequence
Phase loss
Locked rotor
SCRs overload
Overcurrent
Internal fault (watchdog)
Functions Starting Voltage 30 - 80% of the rated voltage
Resources
Programmable Acceleration
Ramp1 – 20 s
Programmable Deceleration
RampOff – 20 s
Motor Rated Current and Soft-
Starter Rated Current Ratio30 - 100%
Ambient
Temperature 0 ... 55ºC - standard operation at rated current
Humidity 0 ... 90% non condensing
Altitude0 ... 1000 m (3,300 ft) - standard operation at rated current
1000...4000m - with current derating (1%/ 100 m (328 ft) above 1000m (13.300ft)
Finishing Color Ultra mat gray (cover) and ultra mat blue (base) WEG standard
Installation Fixing Fixing by bolts or assembly on DIN 35 mm rail
Conformities /
Standards
Safety UL 508 Standard – Industrial Control Equipment / IRAM
Low Voltage IEC 60947-4-2
EMC EMC Directive 89 / 336 / EEC - Industrial Environment
101
2.5Soft Starters
www.pamensky.com
SSW 06 - Soft StarterWEG SSW-06 series soft-starters are micro-
processor controlled and designed to start and
stop induction motors. Excellent acceleration
and deceleration control is achieved with an
optimized cost to benefi t ratio.
Standard Features
• 220 - 575V, 50/60Hz input power supply
(-15/+10%)
• Built-in run rated (AC1) bypass contactor
• Duty cycle: 300% full load amps for 30
seconds, 10 starts per hour
• Voltage ramp or current limit start modes
• Detachable keypad with dual display
(LCD and LED) and copy function
• 90 - 250Vac auxiliary control voltage
• Single 32 bit RISC processor based control
board
• IP00 protected chassis enclosure
• Six isolated 24Vdc programmable digital
inputs
• Three programmable relay outputs (2 Amp -
250V)
• One 0 - 10Vdc programmable analog output
• One 4 - 20mA programmable analog output
• Motor PTC thermistor input
• RS-232 serial interface
• Adjustable acceleration (1-999 seconds) and
deceleration ramps (0 - 299 seconds)
• Adjustable pedestal voltage (25 - 90% of line
voltage)
• Current limitation from 150-500% torque
control
• Diagnostic features: Motor overload, over
current and phase loss, motor immediate
over and under current, SCR over
temperature and fault, line phase loss and
phase sequence, line over and under voltage
• Display readings: Motor current, voltage, kW
and power factor, line voltage and frequency,
four last fault trips, run and power-up timers
• Ambient: 32ºF (0ºC) to 131ºF (55ºC), 3300
ft (1000m) altitude, 90% non-condensing
humidity
• Braking capabilities: Reverse Braking, Optimal
Braking, DC Braking
• ModBUS ( Built-in)
Optional Features
• RS-485 serial interface
• Remote keypad cables and mounting frame
• PC programming software
• Profi bus Expansion Board
• DeviceNet Expansion Board
• Ethernet TCP/IP
• USB Communication Kit
101
Soft Starters2.6
www.pamensky.com
SSW-06 - Part Number Specifi cation
1 2 3 4 5 6 7 8 9 1110
ZS1------OP2223T0085 SSW06
1. SSW-06 Soft Starter
2. Output Rated Current 0010 = 10A
0016 = 16A
0023 = 23A
0030 = 30A
0045 = 45A
0060 = 60A
0085 = 85A
0130 = 130A
0170 = 170A
0205 = 205A
0255 = 255A
0312 = 312A
0365 = 365A
0412 = 412A
0480 = 480A
0604 = 604A
0670 = 670A
0820 = 820A
0950 = 950A
1100 = 1100A
1400 = 1400A
* Selection Table for 2
3. Power Supply: T = Three-phase
4. Power Supply Voltage: 2257 = 220… 575 V
5769 = 575... 690V
5. Language: P = Portuguese
E = English
S = Spanish
6. Product Version: S = Standard
O = With options
7. Degree of Protection (IP):
blank = Standard (see technical specifi cations table)
8. HMI - Human Machine Interface:
Blank = Standard (with LED + LCD HMI)
SI = Without HMI
9. Special Hardware: Blank = Standard
H1 = Fan 115V (950A model)
H2 = Fan 220V (950A up to 1400A model)
10. Special Software: Blank = Standard
S1 = optional with special sofware version
11. End of Part Number: Z
Note: 1 - Communication kits are optional
2 - From 950A up to 1400A models the ventilation voltage must be defi ned (H1 or H2)
3 - 575... 690V are not UL certifi ed
4 - Up to 820A standard built-in bypass
101
2.7Soft Starters
www.pamensky.com
SSW 06 - Table of Products230V - Three Phase
Electrical Data Mechanical Data Purchasing Data
Current
(A)
Maximum Applicable Motor
FrameWeight
(lb)
Degree of
Protection
Dimensions
(in)
H x W x D
Part NumberList
Price3 Leads 6 Leads
VoltageHP Kw HP Kw
10 3 2.2 - - 230 1 7.3 IP20 10.08 x 5.20 x 7.16 SSW060010T2257ESZ $1,559
16 5 3.7 - - 230 1 7.3 IP20 10.08 x 5.20 x 7.16 SSW060016T2257ESZ 1,608
23 7.5 5.5 - - 230 1 7.3 IP20 10.08 x 5.20 x 7.16 SSW060023T2257ESZ 1,768
30 10 7.5 - - 230 1 7.3 IP20 10.08 x 5.20 x 7.16 SSW060030T2257ESZ 1,915
45 15 11 25 18.5 230 2 18.7 IP00 14.57 x 5.20 x 9.61 SSW060045T2257ESZ 2,223
60 20 15 30 22 230 2 18.7 IP00 14.57 x 5.20 x 9.61 SSW060060T2257ESZ 2,453
85 30 22 50 37 230 2 18.7 IP00 14.57 x 5.20 x 9.61 SSW060085T2257ESZ 3,008
130 50 37 75 55 230 2 18.7 IP00 14.57 x 5.20 x 9.61 SSW060130T2257ESZ 3,760
170 60 45 100 75 230 3 40.8 IP00 17.32 x 8.78 x 10.94 SSW060170T2257ESZ 4,605
205 75 55 125 90 230 3 40.8 IP00 17.32 x 8.78 x 10.94 SSW060205T2257ESZ 5,791
255 100 75 150 110 230 4 91.5 IP00 21.65 x 14.57 x 12.24 SSW060255T2257ESZ 8,021
312 125 90 200 150 230 4 91.5 IP00 21.65 x 14.57 x 12.24 SSW060312T2257ESZ 8,509
365 150 110 250 185 230 4 91.5 IP00 21.65 x 14.57 x 12.24 SSW060365T2257ESZ 8,643
412 150 110 - - 230 5 121 IP00 25.59 x 14.57 x 13.66 SSW060412T2257ESZ 10,142
480 200 150 - - 230 5 121 IP00 25.59 x 14.57 x 13.66 SSW060480T2257ESZ 12,556
604 250 185 - - 230 5 121 IP00 25.59 x 14.57 x 13.66 SSW060604T2257ESZ 14,005
670 250 185 - - 230 6 265 IP00 31.30 x 21.26 x 14.05 SSW060670T2257ESZ 15,936
820 300 225 - - 230 6 265 IP00 31.30 x 21.26 x 14.05 SSW060820T2257ESZ 18,832
950 350 260 - - 230 7 236 IP00 33.27 x 22.44 x 13.66 SSW060950T2257ESZ 28,491
1100 450 330 - - 230 8 480 IP00 45.16 x 26.97 x 17.01 SSW061100T2257ESZ 35,737
1400 500 370 - - 230 8 480 IP00 45.16 x 26.97 x 17.01 SSW061400T2257ESZ 45,876
460V - Three Phase
Electrical Data Mechanical Data Purchasing Data
Current
(A)
Maximum Applicable Motor
FrameWeight
(lb)
Degree of
Protection
Dimensions
(in)
H x W x D
Part NumberList
Price3 Leads 6 Leads
VoltageHP Kw HP Kw
10 5 3.7 - - 460 1 7.3 IP20 10.08 x 5.20 x 7.16 SSW060010T2257ESZ $1,559
16 10 7.5 - - 460 1 7.3 IP20 10.08 x 5.20 x 7.16 SSW060016T2257ESZ 1,608
23 15 11 - - 460 1 7.3 IP20 10.08 x 5.20 x 7.16 SSW060023T2257ESZ 1,768
30 20 15 - - 460 1 7.3 IP20 10.08 x 5.20 x 7.16 SSW060030T2257ESZ 1,915
45 30 22 60 45 460 2 18.7 IP00 14.57 x 5.20 x 9.61 SSW060045T2257ESZ 2,223
60 40 30 75 55 460 2 18.7 IP00 14.57 x 5.20 x 9.61 SSW060060T2257ESZ 2,453
85 60 45 100 75 460 2 19 IP00 14.57 x 5.20 x 9.61 SSW060085T2257ESZ 3,008
130 100 75 150 110 460 2 19 IP00 14.57 x 5.20 x 9.61 SSW060130T2257ESZ 3,760
170 125 90 200 150 460 3 41 IP00 17.32 x 8.78 x 10.94 SSW060170T2257ESZ 4,605
205 150 110 250 185 460 3 41 IP00 17.32 x 8.78 x 10.94 SSW060205T2257ESZ 5,791
255 200 150 350 260 460 4 91 IP00 21.65 x 14.57 x 12.24 SSW060255T2257ESZ 8,021
312 250 185 450 330 460 4 91 IP00 21.65 x 14.57 x 12.24 SSW060312T2257ESZ 8,509
365 300 225 500 370 460 4 91 IP00 21.65 x 14.57 x 12.24 SSW060365T2257ESZ 8,643
412 350 260 550 410 460 5 121 IP00 25.59 x 14.57 x 13.66 SSW060412T2257ESZ 10,142
480 400 300 650 485 460 5 121 IP00 25.59 x 14.57 x 13.66 SSW060480T2257ESZ 12,556
604 500 370 800 600 460 5 121 IP00 25.59 x 14.57 x 13.66 SSW060604T2257ESZ 14,005
670 550 410 900 670 460 6 265 IP00 31.30 x 21.26 x 14.05 SSW060670T2257ESZ 15,936
820 600 450 1150 820 460 6 265 IP00 31.30 x 21.26 x 14.05 SSW060820T2257ESZ 18,832
950 700 525 1350 1000 460 7 236 IP00 33.27 x 22.44 x 13.66 SSW060950T2257ESZ 28,491
1100 800 600 1600 1175 460 8 480 IP00 45.16 x 26.97 x 17.01 SSW061100T2257ESZ 35,737
1400 1050 775 2000 1475 460 8 480 IP00 45.16 x 26.97 x 17.01 SSW061400T2257ESZ 45,876
Notes: 3 Leads - Inline Connection
6 Leads - Inside Delta Connection
101
Soft Starters2.8
www.pamensky.com
SSW 06 - Table of Products575V - Three Phase
Electrical Data Mechanical Data Purchasing Data
Current
(A)
Maximum Applicable Motor
FrameWeight
(lb)
Degree of
Protection
Dimensions
(in)
H x W x D
Part NumberList
Price3 Leads 6 Leads
VoltageHP Kw HP Kw
10 7.5 5.5 - - 575 1 7.3 IP20 10.08 x 5.20 x 7.16 SSW060010T5257ESZ $1,559
16 10 7.5 - - 575 1 7.3 IP20 10.08 x 5.20 x 7.16 SSW060016T5257ESZ 1,608
23 20 15 - - 575 1 7.3 IP20 10.08 x 5.20 x 7.16 SSW060023T5257ESZ 1,768
30 25 18.5 - - 575 1 7.3 IP20 10.08 x 5.20 x 7.16 SSW060030T5257ESZ 1,915
45 40 30 75 55 575 2 18.7 IP00 14.57 x 5.20 x 9.61 SSW060045T5257ESZ 2,223
60 50 37 100 75 575 2 18.7 IP00 14.57 x 5.20 x 9.61 SSW060060T5257ESZ 2,453
85 75 55 150 110 575 2 19 IP00 14.57 x 5.20 x 9.61 SSW060085T5257ESZ 3,008
130 125 90 200 150 575 2 19 IP00 14.57 x 5.20 x 9.61 SSW060130T5257ESZ 3,760
170 150 110 300 220 575 3 41 IP00 17.32 x 8.78 x 10.94 SSW060170T5257ESZ 4,605
205 200 150 350 260 575 3 41 IP00 17.32 x 8.78 x 10.94 SSW060205T5257ESZ 5,791
255 250 185 450 330 575 4 91 IP00 21.65 x 14.57 x 12.24 SSW060255T5257ESZ 8,021
312 300 225 550 410 575 4 91 IP00 21.65 x 14.57 x 12.24 SSW060312T5257ESZ 8,509
365 350 260 650 485 575 4 91 IP00 21.65 x 14.57 x 12.24 SSW060365T5257ESZ 8,643
412 450 330 750 550 575 5 121 IP00 25.59 x 14.57 x 13.66 SSW060412T5257ESZ 10,142
480 500 370 850 630 575 5 121 IP00 25.59 x 14.57 x 13.66 SSW060480T5257ESZ 12,556
604 600 450 1100 800 575 5 121 IP00 25.59 x 14.57 x 13.66 SSW060604T5257ESZ 14,005
670 650 485 1200 900 575 6 265 IP00 31.30 x 21.26 x 14.05 SSW060670T5257ESZ 15,936
820 750 550 1500 1200 575 6 265 IP00 31.30 x 21.26 x 14.05 SSW060820T5257ESZ 18,832
950 850 630 1750 1290 575 7 236 IP00 33.27 x 22.44 x 13.66 SSW060950T5257ESZ 28,491
1100 1000 750 2000 1475 575 8 480 IP00 45.16 x 26.97 x 17.01 SSW061100T5257ESZ 35,737
1400 1300 1000 2500 1850 575 8 480 IP00 45.16 x 26.97 x 17.01 SSW061400T5257ESZ 45,876
Notes: 3 Leads - Inline Connection
6 Leads - Inside Delta Connection
101
2.9Soft Starters
www.pamensky.com
SSW 06 - AccessoriesKeypad and Keypad Cables
Description Part Number List Price
Local Keypad with LED and LCD SSW06HMILCD $230
Remote Keypad Frame Kit KMR-SSW-06 31
1m (3.3 ft) Remote Keypad Cable CFW09HMI091 31
2m (6.6 ft) Remote Keypad Cable CFW09HMI092 39
3m (10 ft) Remote Keypad Cable CFW09HMI093 50
5m (16 ft) Remote Keypad Cable CFW09HMI095 75
7.5m (25 ft) Remote Keypad Cable (Requires CFW09KMR09) CFW09HMI097 88
10m (33 ft) Remote Keypad Cable (Requires CFW09KMR09) CFW09HMI0910 108
Communication
Description Part Number List Price
Profi bus DP Communication Kit KFB PD SSW06 $1,045
DeviceNet Communication Kit KFB DN SSW06 897
Interface for RS-485 Communication KRS 485 183
Ethernet/IP Communication Kit KFB ENIP SSW06 2,070
IP20 Kits
Description Part Number List Price
SSW06 IP20 Kit - Frame Size 2 KIT IP20 SSW06 M2 $210
SSW06 IP20 Kit - Frame Size 3 KIT IP20 SSW06 M3 236
SSW06 IP20 Kit - Frame Size 4 & 5 KIT IP20 SSW06 M4/M5 254
SSW06 IP20 Kit - Frame Size 6 KIT IP20 SSW06 M6 517
I/O Expansion
Description Part Number List Price
I/Os Expansion Module for SoftPLC applications SSW06 KEIO $758
101
Soft Starters2.10
www.pamensky.com
SSW 06 - Technical Data
Power Supply
Power 220 to 575 Vac -15% to +10%, or 198 to 632 Vac
Control 110 to 230 Vac -15% to +10%, or 94 to 253 Vac
Fan
Models from 255 to 820 A: 115 Vac (104 to 127) Vac / 230 vac (207 to 253) Vac
Model 950 A: 115 Vac (103,5 to 122) Vac / 230 Vac (207 to 243,8) Vac
Models from 1100 to 1400 A: 230 vac (207 to 243,8) Vac
Frequency 50 to 60 Hz (+/- 10%), or 45 to 66 Hz
Degree of protection Metallic cabinet IP00
Control
Control method Motor voltage variation (Three phase induction motor)
CPU 32-Bit RISC microcontroller
Types of control
Voltage ramp
Current limitation
Current limitation ramp
Pump control
Torque control 1, 2 or 3 points
Starting Duty cycles
(10 starts / hour)
Rated 300% (3 x I nom.) during 30 s for 3-cable connection and during 25 s for 6-cable connection
Heavy450% (4,5 x I nom.) during 30 s with 33% rated current reduction;
450 % ( 4,5 x I nom.) during 25 s for 6-cable connection
Inputs Digital5 x 24 Vdc isolated programmable inputs
1 x 24 Vdc insolated programmable input for motor PTC
Outputs
Relay 3 programmable outputs 250 Vac / 2 A: (2 x NA) + (1 x NO + NC – Fault)
Analog1 Programmable output (11 bits) 0…10 Vdc
1 programmable output (11 bits) 0...20 mA or 4...20 mA
Safety Protections
Overvoltage Power supply phase loss
Undervoltage Output phase loss (motor)
Voltage imbalance Thyristor failure
Undercurrent CPU failure (watch dog)
Overcurrent Programming error
Current imbalance Serial communication error
Overload (motor) – i²t Self-check error
Thyristors over temperature HMI-SSW06 communication error
Motor over temperature / PTC Starting time expired
Phase sequence failure Fieldbus communication error
External fault Serial communication error
Open by-pass contact failure (1) Undervoltage in the electronic board
Closed by-pass contact failure (1) Frequency out of range
Overcurrent in the by-pass (1) Undercurrent before by-pass closing (1)
Functions/resources Standard
Removable human-machine interface with double display LED + LCD
Programming access password
HMI language selection: Portuguese, English, Spanish and German
Control type selection: Voltage ramp, current limitation, current
Limitation ramp, pump control and torque control
Local/ Remote operation selection
Self-checking and automatic fault reset
Oriented start-up according to the control type
Standard or within-the-delta (6 leads) connection
All protections and functions available in both types of connection to the motor
PUMP CONTROL function (protection against “water hammer” in pumps)
COPY function (Soft-starter to HMI or HMI to soft-starter)
Built-in by-pass for the models 85 to 820 A
Serial interface RS-232 with Modbus RTU protocol. RS-485 optional
Insolated input for motor PTC
Standard or user parameters reset (Brings back the standard or user values)
Special features: Running hours
Programmable over and undervoltage and voltage imbalance between phases
Programmable over and undercurrent and current imbalance between phases
Under and overcurrent before by-pass
Programmable immediate overcurrent
Programmable time for immediate overcurrent
Programmable immediate undercurrent
Programmable time for immediate undercurrentProgrammable line nominal voltageFully programmable voltage rampProgrammable current limitationProgrammable current rampProgrammable pump controlFully fl exible torque controlAuto reset of the programmable thermal memory Thermal class protection (motor overload) programmable from class 5 to 45.
101
2.11Soft Starters
www.pamensky.com
Notes: (1) Models from 10A to 820A (2) Models from 85A to 1400A approved
SSW 06 - Technical Data
Functions/resourcesOptional
Frame for remote HMI
Cable to interconnect the soft-starter with the remote HMI 1, 2, 3 and 5 m
Rs-485 communication kit
PROFIBUS-DP communication kit
Device Net communication kit
IP20 protection for the models from 85 up to 820 A
Human-Machine
Interface
(HMI-SSW06-LCD)
Controls Start, stop, reset and parameterization (main functions programming)
Supervision
Increase and decrease parameters and their values
Motor current (% Soft-starter In)
Motor current (% Motor In)
Motor current (A)
Line frequency (0…99.9 Hz)
Line voltage (0…999 V)
Output voltage (0…999 V)
Motor torque (% motor I n)
Load active power – (kW)
Load apparent power – (kVA)
Soft-starter status
Digital and analog inputs and outputs status
Load Cos φ (0.00 – 0.99)
Energized hours
Enabled hours
Last six error codes memory
Soft-starter software version
Enviroment Conditions
Temperature0 to 55ºC (Models from 85 to 820 A) standard operation at rated current
0 to 40ºC (Models from 950 to 1400 A) standard operation at rated current
Humdity 5...90 %, non-condensing
Altitude0... 1000 m: standard operation at rated current
1000... 4000 m; with output current reduction of 1%/100 m, over 1000 m
Finishing Painting ColorCover: ultra mat gray
Cabinet: ultra mat blue
Standards
Safety UL 508 Standard – Industrial control equipment (2)
Low voltage EN 60947-4-2 Standard; LVD 73/23/EEC – Low voltage directive
EMC EMC directive 89 / 336 / EEC – Industrial environment
UL (USA) / cUL (Canadá) Underwritters Laboratories Inc. – USA (2)
CE (Europe) Certifi ed by EPCOS
IRAM (Argentina) Instituto Argentino de Normalización (2)
C-Tick (Australia) Australian Communications Authority
101
Soft Starters2.12
www.pamensky.com
SSW 07 - Soft Starter
The SSW-07 Soft Starter from WEG was designed for high
performance starting and stopping while providing an excellent
cost-benefi t ratio. The Starter is designed to be easily set-up and
makes start up and daily activities simpler. Excellent for applications
with heavy loads, the SSW-07 is suitable for Crusher applications
as well as conveyors, hammer mills, centrifuges and many others.
Standard Features
• Strong reduction on mechanical stresses
over the coupling and transmission devices
(gearboxes, pulleys, gears, conveyors, etc.)
during the start
• Eliminates mechanical shock
• Increases motor and machine mechanical
equipment lifetime due to the elimination of
mechanical shock
• Easy operation, setup, maintenance &
installation
• Simple electric installation
• Operates in environments up to 55ºC (without
current reduction for all models)
• Integral, electronic motor protection
• Built-in electronic thermal relay
• Avoids the “Water Hammer” in pump
applications
• Limitation of voltage drop during start
• Universal voltage (220 to 575 Vac)
• Switched type power supply with EMC fi lter
for the control electronics (110 to 240 Vac)
• Voltage monitoring of the electronics to back-
up l2t values (thermal image)
• Local Keypad
Optional Features
• RS 485 Serial Interface
• RS 232 Serial Interface
• Remote keypad
• PTC Kit
• IP20 Kit for M3
101
2.13Soft Starters
www.pamensky.com
1. SSW-07 Soft Starter
2. Output Rated Current 0017 = 17A
0024 = 24A
0030 = 30A
0045 = 45A
0061 = 61A
0085 = 85A
0130 = 130A
0171 = 171A
0200 = 200A
0255 = 255A
0312 = 312A
0365 = 365A
0412 = 412A
* Selection Table for 2
3. Power Supply: T = Three-phase
4. Power Supply Voltage: 5 = 220 to 575 V
5. Product Version: S = Standard
O = With options
6. Enclosure: blank = Standard (see technical specifi cations table)
IP = IP20 for models from 130 A to 412 A
7. Special Hardware: Blank = Standard
8. Special Software: Blank = Standard
9. End of Part Number: Z
SSW-07 - Part Number Specifi cation
1 2 3 4 5 6 7 8 9
Z------S5T0017SSW07
101
Soft Starters2.14
www.pamensky.com
SSW 07 - Table of Products230V - Three Phase
Electrical Data Mechanical Data Purchasing Data
Current
(A)
Maximum Applicable Motor
FrameWeight
(lb)
Degree of
Protection
Dimensions
(in)
H x W x D
Part NumberList
PriceHP Kw Voltage
17 5 3.7 230 1 2.90 iP20 6.38 x 3.74 x 6.18 SSW070017T5SZ $1,266
24 7,5 5.5 230 1 2.90 iP20 6.38 x 3.74 x 6.18 SSW070024T5SZ 1,346
30 10 7.5 230 1 2.90 iP20 6.38 x 3.74 x 6.18 SSW070030T5SZ 1,386
45 15 11 230 2 7.28 iP20 8.19 x 5.67 x 7.99 SSW070045T5SZ 1,558
61 20 15 230 2 7.28 iP20 8.19 x 5.67 x 7.99 SSW070061T5SZ 1,736
85 30 22 230 2 7.28 iP20 8.19 x 5.67 x 7.99 SSW070085T5SZ 2,070
130 50 37 230 3 16.80 IP00 10.90 x 8.78 x 8.66 SSW070130T5SZ 2,560
171 60 45 230 3 16.80 IP00 10.90 x 8.78 x 8.66 SSW070171T5SZ 3,210
200 75 55 230 3 16.80 IP00 10.90 x 8.78 x 8.66 SSW070200T5SZ 3,778
255 100 75 230 4 20.32 IP00 13.00 x 8.94 x 9.53 SSW070255T5SH1Z 5,026
312 125 90 230 4 20.32 IP00 13.00 x 8.94 x 9.53 SSW070312T5SH1Z 5,457
365 150 110 230 4 20.32 IP00 13.00 x 8.94 x 9.53 SSW070365T5SH1Z 5,671
412 150 110 230 4 20.32 IP00 13.00 x 8.94 x 9.53 SSW070412T5SH1Z 6,655
460V - Three Phase
Electrical Data Mechanical Data Purchasing Data
Current
(A)
Maximum Applicable Motor
FrameWeight
(lb)
Degree of
Protection
Dimensions
(in)
H x W x D
Part NumberList
PriceHP Kw Voltage
17 10 7.5 460 1 2.90 iP20 6.38 x 3.74 x 6.18 SSW070017T5SZ $1,266
24 15 11 460 1 2.90 iP20 6.38 x 3.74 x 6.18 SSW070024T5SZ 1,346
30 20 15 460 1 2.90 iP20 6.38 x 3.74 x 6.18 SSW070030T5SZ 1,386
45 30 22 460 2 7.28 iP20 8.19 x 5.67 x 7.99 SSW070045T5SZ 1,558
61 40 30 460 2 7.28 iP20 8.19 x 5.67 x 7.99 SSW070061T5SZ 1,736
85 60 45 460 2 7.28 iP20 8.19 x 5.67 x 7.99 SSW070085T5SZ 2,070
130 100 75 460 3 16.80 IP00 10.90 x 8.78 x 8.66 SSW070130T5SZ 2,560
171 125 90 460 3 16.80 IP00 10.90 x 8.78 x 8.66 SSW070171T5SZ 3,210
200 150 110 460 3 16.80 IP00 10.90 x 8.78 x 8.66 SSW070200T5SZ 3,778
255 200 160 460 4 20.32 IP00 13.00 x 8.94 x 9.53 SSW070255T5SH1Z 5,026
312 250 185 460 4 20.32 IP00 13.00 x 8.94 x 9.53 SSW070312T5SH1Z 5,457
365 300 220 460 4 20.32 IP00 13.00 x 8.94 x 9.53 SSW070365T5SH1Z 5,671
412 350 260 460 4 20.32 IP00 13.00 x 8.94 x 9.53 SSW070412T5SH1Z 6,655
575V - Three Phase
Electrical Data Mechanical Data Purchasing Data
Current
(A)
Maximum Applicable Motor
FrameWeight
(lb)
Degree of
Protection
Dimensions
(in)
H x W x D
Part NumberList
PriceHP Kw Voltage
17 15 11 575 1 2.90 iP20 6.38 x 3.74 x 6.18 SSW070017T5SZ $1,266
24 20 15 575 1 2.90 iP20 6.38 x 3.74 x 6.18 SSW070024T5SZ 1,346
30 25 18.5 575 1 2.90 iP20 6.38 x 3.74 x 6.18 SSW070030T5SZ 1,386
45 40 30 575 2 7.28 iP20 8.19 x 5.67 x 7.99 SSW070045T5SZ 1,558
61 50 37 575 2 7.28 iP20 8.19 x 5.67 x 7.99 SSW070061T5SZ 1,736
85 75 55 575 2 7.28 iP20 8.19 x 5.67 x 7.99 SSW070085T5SZ 2,070
130 125 90 575 3 16.80 IP00 10.90 x 8.78 x 8.66 SSW070130T5SZ 2,560
171 150 110 575 3 16.80 IP00 10.90 x 8.78 x 8.66 SSW070171T5SZ 3,210
200 200 150 575 3 16.80 IP00 10.90 x 8.78 x 8.66 SSW070200T5SZ 3,778
255 250 185 575 4 20.32 IP00 13.00 x 8.94 x 9.53 SSW070255T5SH1Z 5,026
312 300 220 575 4 20.32 IP00 13.00 x 8.94 x 9.53 SSW070312T5SH1Z 5,457
365 350 260 575 4 20.32 IP00 13.00 x 8.94 x 9.53 SSW070365T5SH1Z 5,671
412 400 330 575 4 20.32 IP00 13.00 x 8.94 x 9.53 SSW070412T5SH1Z 6,655
101
2.15Soft Starters
www.pamensky.com
SSW 07 - AccessoriesKeypad and Keypad Cables
Description Part Number List Price
Local Keypad HMI-LOCAL-SSW07/08 $160
Remote Keypad Kit HMI-REMOTE-SSW07 312
1m (3.3 ft.) Remote Keypad Cable CAB-RS-1 23
2m (6.6 ft.) Remote Keypad Cable CAB-RS-2 31
3m (10 ft.) Remote Keypad Cable CAB-RS-3 42
5m (15 ft.) Remote Keypad Cable CAB-RS-5 52
7.5m (25 ft.) Remote Keypad Cable CAB-RS-7.5 62
10m (33 ft.) Remote Keypad Cable CAB-RS-10 73
Communication
Description Part Number List Price
RS-232 Communication Kit KRS-232-SSW07/08 $128
RS-485 Communication Kit KRS-485-SSW07/08 150
Kits
Description Part Number List Price
Ventilation Kit M2 (Frame Size 2, 45 to 85A) SSW07M2V.K $70
Ventilation Kit M3 (Frame Size 3, 130 to 200A) SSW07M3V.K 101
PTC Kit for motor KITPTCSSW07/08 118
IP20 Kit for M3 (Frame Size 3, 130 to 200A) KITIP20SIZE3 60
IP20 Kit for M4 (Frame Size 4, 255 to 412A) KITIP20SIZE4 115
101
Soft Starters2.16
www.pamensky.com
Power Supply
Power 220 to 575 Vac
Control 110 to 240 Vac (-15% to +10%), or 94 to 264 Vac
Frequency 50 to 60 Hz (+/- 10%), or 45 to 66 Hz
Degree of
protectionInjected plastic case
IP20 in models from 17 to 85 A
IP00 in models from 130 to 200 A (IP20 as option)
Control
Control Method Motor Voltage Variation
CPU DSP type microprocessor (Digital Signal Processor)
Types of Control Voltage ramp
Current limit
Starting Cycle (1) Normal 300% (3 x Inom.) during 30 s, 10 starts per hour ( every 6 minutes)
Inputs Digital 3 isolated programmable inputs
Outputs Relay 2 relays with NO contacts, 240Vac, 1A, programmable functions
Starting Duty Cycle
Normal 17 - 30A 300%
Normal 45 - 200A 3 starts
With optional ventilation kit 45-200A 10 starts
Safety
Protections (Standard)
Overcurrent Locked rotor
Overcurrent before By-pass Excess starting time
Phase loss Frequency outside tolerance
Inverted phase sequence By-pass contact open
Overtemperature in power heatsink Undervoltage in control supply
Motor overload (class 5 to 30)
Protections (with Accessory)
Undercurrent Programming error
Current imbalance Serial communication error
Undercurrent before by-pass HMI communication error
External fault Overtemperature in motor PTC
Functions /
ResourcesStandard
Voltage ramp (Initial voltage: 30% to 90%)
Current limitation (150% to 450% of SSW-07 rated current)
Starting time (1 to 40s)
Kick Start (Off - 0.2 to 2s)
Deceleration ramp ( 0 to 40s)
Motor and SSW-07 current relation (50% to 100%)
Faults automatic-reset
Thermal memory automatic-reset
Factory standard reset
Soft-starter built-in By-pass
Programming
Accessory
(HMI or Serial
communication)
Command On, Off / Reset and Parameterization (function programming)
Additional Functions/Resources
Starting time up to 999s
Deceleration time up to 999s
Program enabling password
Selection for Local / Remote operation
COPY function (SSW-07 >>> HMI and HMI >>> SSW-07)
Programmable rated voltage
Supervision
Motor current (%Soft-Starter In)
Motor current (%motor In)
Motor current (A)
Current indication in each phase R-S-T
Supply network frequency
Apparent power supplied to load (kVA)
Soft-Starter status
Digital input and output status
Last 4 faults
Soft-Starter Software Version
Heatsink temperature
Motor thermal protection status
Accessories and
Options Options
Plug-in type local HMI
HMI remote Kit
5 and 10m cable for remote HMI interconnection
RS-232 communication kit
SSW-07 interconnection leads >>> PC Serial (RS-232) 3 and 10m
RS-485 communication kit
Motor PTC kit
Ventilation kit for size 2 (45 to 85 A)
Ventilation kit for size 3 (130 to 200 A)
IP20 kit for size 3 (130 to 200 A)
Finishing ColorLid: Ultra mat gray
Cabinet: Ultra mat blue
Conformities /
Standards
Safety UL 508 Standard- Industrial Control Equipment
Low voltage EN60947-4-2; LVD 2006/95/EC Standard – Low voltage Directive
EMC EMC 89/336/EEC Directive – Industrial Environment
UL (USA) / cUL (Canada) Underwriters Laboratories Inc. – USA
CE (Europe) Conformity test conducted by EPCOS
C-Tick (Australia) Australian Communication Authority
SSW 07 - Technical Data
101
3.1Panels
www.pamensky.com
EDP - Enclosed Drive PanelThe Enclosed Drive Panel is an industrial general purpose AC motor control and protection
package. It is designed for simple and quick installation and start-up, requiring only input
power and output motor connections.
The Enclosed Drive Panel is built to complement the ruggedness and reliability of WEG
electric motors, providing a complete, simple, and cost effective AC motor control, monitor
and protection solution.
Standard Features
• V/Hz and Sensorless Vector Control
• 230V, 460V or 575V Input Voltage
• 2 Isolated Analog Inputs
• 6 Programmable Digital Inputs
• 3 Programmable Relay Outputs
• 2 Analog Outputs
• 150% Overload 1min
Standard Panel Includes
• Variable Frequency Drive CFW09
• Keypad Mounted to Panel Door
• Through Door Disconnect
• Control Power Transformer
• NEMA 12 Ventilated Enclosure
• Canadian Certifi cation
Optional Features
• Line Reactor
• Load Reactor
• Panel Control Option
• Start/Stop Pushbuttons
• Run/Stop/Fault Pilot Lights
• Local/Remote Selector Switch
Applications
• Pumps
• Fans
• Blowers
• Conveyors
• Rollout tables
• Agitators
• Mixers
Wall Mounted230V: 30 - 50HP: 86 - 130A
460V: 30 - 75HP: 45 - 105A
575V: 30HP: 32A
Free Standing 230V: 60 - 75HP: 180 - 240A
460V: 100 - 500HP: 142 - 600A
575V: 40 - 500HP: 44 - 472A
101
Panels3.2
www.pamensky.com
EDP - Table of Products230V
Standard Product Optional Features
Current (A) HP*
Part Number List Price Dimensions
Panel Control Line Reactor Load Reactor
CT VT CT VT Part Number List Price Part Number List Price Part Number List Price
86 105 30 40 EDP09.86/230 $18,129 60 x 36 x 16 EDP-PNLCTRL $681 EDP-KDRF24LI $741 EDP-KDRF24LO $741
105 130 40 50 EDP09105/230 $22,048 72 x 36 x 16 EDP-PNLCTRL $681 EDP-KDRF25LI $1,036 EDP-KDRF25LO $1,036
130 150 50 50 EDP09130/230 $23,032 72 x 36 x 16 EDP-PNLCTRL $681 EDP-KDRF26LI $1,194 EDP-KDRF26LO $1,194
142 174 50 60 EDP09142/230 $25,300 72 x 36 x 18 EDP-PNLCTRL $681 EDP-KDRF26LI $1,212 EDP-KDRF26LO $1,212
180 60 EDP09180/230 $30,104 72 x 36 x 18 EDP-PNLCTRL $681 EDP-KDRI22LI $1,390 EDP-KDRI22LO $1,390
240 75 EDP09240/230 $36,985 72 x 36 x 18 EDP-PNLCTRL $681 EDP-KDRI23LI $1,415 EDP-KDRI23LO $1,415
575V
Standard Product Optional Features
Current (A) HP*
Part Number List Price Dimensions
Panel Control Line Reactor Load Reactor
CT VT CT VT Part Number List Price Part Number List Price Part Number List Price
32 32 30 30 EDP09.32/575 $13,790 48 x 36 x 16 EDP-PNLCTRL $681 EDP-KDRD42LI $535 EDP-KDRD42LO $535
44 53 40 50 EDP09.44/575 $17,278 72 x 36 x 18 EDP-PNLCTRL $681 EDP-KDRC43LI $570 EDP-KDRC43LO $570
53 63 50 60 EDP09.53/575 $19,023 72 x 36 x 18 EDP-PNLCTRL $681 EDP-KDRC44LI $605 EDP-KDRC44LO $605
63 79 60 75 EDP09.63/575 $20,753 72 x 36 x 18 EDP-PNLCTRL $681 EDP-KDRF46LI $761 EDP-KDRF46LO $761
79 99 75 100 EDP09.79/575 $23,280 72 x 36 x 18 EDP-PNLCTRL $681 EDP-KDRF47LI $786 EDP-KDRF47LO $786
107 147 100 150 EDP09107/575 $35,071 72 x 72 x 18 EDP-PNLCTRL $681 EDP-KDRF47LI $1,058 EDP-KDRF47LO $1,058
147 196 150 200 EDP09147/575 $42,721 72 x 72 x 18 EDP-PNLCTRL $681 EDP-KDRH44LI $1,433 EDP-KDRH44LO $1,433
211 211 200 200 EDP09211/575 $48,646 72 x 72 x 18 EDP-PNLCTRL $681 EDP-KDRI42LI $1,517 EDP-KDRI42LO $1,517
247 315 250 300 EDP09247/575 $63,850 90 x 72 x 36 EDP-PNLCTRL $681 EDP-KDRG47LI $1,675 EDP-KDRG47LO $1,675
315 343 300 350 EDP09315/575 $68,011 90 x 72 x 36 EDP-PNLCTRL $681 EDP-KDRG45LI $1,938 EDP-KDRG45LO $1,938
343 418 350 400 EDP09343/575 $84,040 90 x 72 x 36 EDP-PNLCTRL $681 EDP-KDRJ45LI $2,150 EDP-KDRJ45LO $2,150
418 472 400 500 EDP09418/575 $89,672 90 x 72 x 36 EDP-PNLCTRL $681 EDP-KDRJ43LI $2,254 EDP-KDRJ43LO $2,254
472 555 500 600 EDP09472/575 $98,022 90 x 72 x 36 EDP-PNLCTRL $681 EDP-KDRL45LI $2,675 EDP-KDRL45LO $2,675
460V
Standard Product Optional Features
Current (A) HP*
Part Number List Price Dimensions
Panel Control Line Reactor Load Reactor
CT VT CT VT Part Number List Price Part Number List Price Part Number List Price
45 54 30 40 EDP09.45/460 $14,204 48 x 36 x 16 EDP-PNLCTRL $681 EDP-KDRD2LI $644 EDP-KDRD2LO $644
60 70 40 50 EDP09.60/460 $15,959 60 x 36 x 16 EDP-PNLCTRL $681 EDP-KDRC1LI $697 EDP-KDRC1LO $697
70 86 50 60 EDP09.70/460 $16,605 60 x 36 x 16 EDP-PNLCTRL $681 EDP-KDRF2LI $792 EDP-KDRF2LO $792
86 105 60 75 EDP09.86/460 $19,785 72 x 36 x 16 EDP-PNLCTRL $681 EDP-KDRF4LI $810 EDP-KDRF4LO $810
105 130 75 100 EDP09105/460 $22,499 72 x 36 x 16 EDP-PNLCTRL $681 EDP-KDRF3LI $1,058 EDP-KDRF3LO $1,058
142 174 100 125 EDP09142/460 $25,270 72 x 36 x 18 EDP-PNLCTRL $681 EDP-KDRH3LI $1,201 EDP-KDRH3LO $1,201
180 150 EDP09180/460 $32,953 72 x 36 x 18 EDP-PNLCTRL $681 EDP-KDRH1LI $1,673 EDP-KDRH1LO $1,673
211 150 EDP09211/460 $36,339 72 x 36 x 18 EDP-PNLCTRL $681 EDP-KDRG3LI $2,084 EDP-KDRG3LO $2,084
240 200 EDP09240/460 $37,187 72 x 36 x 18 EDP-PNLCTRL $681 EDP-KDRG3LI $2,084 EDP-KDRG3LO $2,084
312 250 EDP09312/460 $50,888 72 x 72 x 24 EDP-PNLCTRL $681 EDP-KDRG1LI $2,280 EDP-KDRG1LO $2,280
361 300 EDP09361/460 $52,144 72 x 72 x 24 EDP-PNLCTRL $681 EDP-KDRG2LI $2,328 EDP-KDRG2LO $2,328
450 350 EDP09450/460 $64,021 72 x 72 x 24 EDP-PNLCTRL $681 EDP-KDRJ2LI $2,673 EDP-KDRJ2LO $2,673
515 400 EDP09515/460 $73,451 72 x 72 x 24 EDP-PNLCTRL $681 EDP-KDRJ1LI $2,935 EDP-KDRJ1LO $2,935
600 500 EDP09600/460 $83,399 72 x 72 x 24 EDP-PNLCTRL $681 EDP-KDRL2LI $5,055 EDP-KDRL2LO $5,055
* Please note that HP reference is for 4 pole motors (1800 RPM). To size the drive correctly please confi rm the Current (A).
Sizing table is used for approximation only, fi nal sizing subject to review of application/load details.
Standard Panel includes drive, fuse disconnect, control transformer, door mounted keypad and fi ltered fan mounted in a NEMA 12 ventilated enclosure.
Panel Control Option Includes Start/Stop Pushbuttons, Run/Stop/Fault Pilot Lights and Local/Remote Selector Switch.
101
3.3Panels
www.pamensky.com
EDP - Sample Wiring Diagram
This wiring diagram is reprinted for illustrative purposes only and may be subject to change.
101
Panels3.4
www.pamensky.com
GPH - Combination Soft StarterThe GPH Series of WEG Combination Soft Starters is an industrial general purpose
AC motor Soft Starter package designed for simple and quick installation and
start-up, requiring only input power and output motor connections. The NEMA
4/12 enclosure is ideal for dusty or wet environments. The GPH starters are built
to complement the ruggedness and reliability of WEG motors, providing a complete
and cost effective AC motor starting and protection solution.
Standard Features
• Rated 500%
• 5 - 250HP at 230V, 10 -500HP at 460V
and 15 - 500HP at 575V
• NEMA 4/12 wall mount enclosure suitable
for dusty, wet, or outdoor applications
• Circuit breaker with door mounted
operator provides built-in short circuit
protection and input power disconnect
• Automatic run rated bypass contactor
• Fused Control Power Transformer (CPT)
• Start and Stop Pushbuttons and Run and
Fault Pilot Lights on the front cover
• Keypad with protective cover mounted on
enclosure door, all parameter changes are
through the cover-mounted keypad. Dust
and water stay out of the enclosure.
• Monitoring of current, voltage, kVA and
kW can be done from the outside
Standard Panel Includes
• Soft Starter SSW 07
• Through Door Disconnect
• Control Power Transformer
• NEMA 4/12 Enclosure
Applications
• Pumps
• Fans
• Blowers
• Compressors
• Conveyors
• Mixers
• Crushers
• Saws
101
3.5Panels
www.pamensky.com
GPH - Table of Products230V
HP Current (A) Part Number List Price Dimensions
5 17 GPH070017230 $5,084 24x24x12
7.5 24 GPH070024230 $5,445 24x24x12
10 30 GPH070030230 $5,478 24x24x12
15 45 GPH070045230 $5,440 24x24x12
20 61 GPH070061230 $6,897 24x24x12
30 85 GPH070085230 $7,182 24x24x12
50 130 GPH070130230 $9,584 42x30x12
60 171 GPH070171230 $11,511 42x30x12
75 200 GPH070200230 $11,997 42x30x12
100 255 GPH070255230 $13,356 60x36x16
125 312 GPH070312230 $13,680 60x36x16
150 365 GPH070365230 $13,841 60x36x16
150 412 GPH070412230 $17,210 60x36x16
460V
HP Current (A) Part Number List Price Dimensions
10 17 GPH070017460 $5,084 24x24x12
15 24 GPH070024460 $5,445 24x24x12
20 30 GPH070030460 $5,478 24x24x12
30 45 GPH070045460 $5,440 24x24x12
40 61 GPH070061460 $6,897 24x24x12
60 85 GPH070085460 $7,182 24x24x12
100 130 GPH070130460 $9,584 42x30x12
125 171 GPH070171460 $11,511 42x30x12
150 200 GPH070200460 $11,997 42x30x12
200 255 GPH070255460 $13,356 60x36x16
250 312 GPH070312460 $13,680 60x36x16
300 365 GPH070365460 $13,841 60x36x16
350 412 GPH070412460 $17,210 60x36x16
575V
HP Current (A) Part Number List Price Dimensions
15 17 GPH070017575 $5,084 24x24x12
20 24 GPH070024575 $5,445 24x24x12
25 30 GPH070030575 $5,478 24x24x12
40 45 GPH070045575 $5,440 24x24x12
50 61 GPH070061575 $6,897 24x24x12
75 85 GPH070085575 $7,182 24x24x12
125 130 GPH070130575 $9,584 42x30x12
150 171 GPH070171575 $11,511 42x30x12
200 200 GPH070200575 $11,997 42x30x12
250 255 GPH070255575 $13,356 60x36x16
300 312 GPH070312575 $13,680 60x36x16
350 365 GPH070365575 $13,841 60x36x16
400 412 GPH070412575 $17,210 60x36x16
101
Panels3.6
www.pamensky.com
GPH - Sample Wiring Diagram
FusedDisconnect
Motor
DoorMountedKeypad
ControlTransformer120VSecondary
R
S
U
V
WT
A1
DI1
DI3
DI2
13
Fuse
Fuse
Fuse
Run
Fault
Start
Stop
14/23
24
A2
102
Industrial Control Products 4.1
www.pamensky.com
PESW - Enclosed Motor StarterWEG offers non-reversing and non-combination NEMA-4X magnetic starter up to 75HP at
460V.
Featuring components that meet IEC design standards and UL horsepower ratings, including
WEG contactors and overload relays, the PESW magnetic starters are ideal to help protect
motors and ensure smooth operation year-after-year. Assembled together in a NEMA 4X
enclosure with two options.
WEG PESW starters are recommended for all single and three phase applications where
across-the-line starters can be applied.
Standard Features
• High horsepower ratings in four compact
sizes
• Bimetallic Overload Relays
• Adjustable trip current
• Direct heated bimetallic elements – class
10
• Ambient temperature compensated
• Phase-loss sensitivity protection
• Selectable Manual or Automatic RESET
• Electrically isolated NO-NC auxiliary
contacts
• NEMA 4X polymeric enclosure with
knockouts
Ground and Neutral (supplied as
standard)
Start/Stop contacts independent
from main contactor and from
thermal overload relay
Thermal overload relay reset
integrated to the stop button up to
25-30HP - 460V, 25HP - 575V
102
Industrial Control Products4.2
www.pamensky.com
PESW - Part Number Specifi cation
6
X --
5
A
2
S
4
V24
3
105
1
PESW
7
RM38
1. PESW Enclosed Starter, Non-Combination, Non-Reversing
2. Number of Phases: S = Single Phase
Blank = Three Phase
3. CWM (Contactor) Type:
Code Contactor Part Number Description
9 CWM9 - 10 - 30 Contactor 9 A, 1NO
12 CWM12 - 10 - 30 Contactor 12 A, 1NO
18 CWM18 - 10 - 30 Contactor 18 A, 1NO
25 CWM25 - 11 - 30 Contactor 25 A, 1NO/1NC
32 CWM32 - 11 - 30 Contactor 32 A, 1NO/1NC
40 CWM40 - 11 - 30 Contactor 40 A, 1NO/1NC
50 CWM50 - 11 - 30V Contactor 50 A, 1NO/1NC
65 CWM65 - 11 - 30 Contactor 65 A, 1NO/1NC
80 CWM80 - 11 - 30 Contactor 80 A, 1NO/1NC
95 CWM95 - 11 - 30 Contactor 95 A, 1NO/1NC
105 CWM105 - 11 - 30 Contactor 105 A, 1NO/1NC
4. Control Voltage: Code Coil Voltage Coil Part Number Description
V18 120 V BCA4 - 25V-18 AC coil contactor 9 -25 A
V24 208-240 V BCA4 - 25V-24 AC coil contactor 9 -25 A
V47 480 V BCA4 - 25V-47 AC coil contactor 9 -25 A
V56 575 V BCA4 - 25V-56 AC coil contactor 9 -25 A
V18 120 V BCA4 - 40V-18 AC coil contactor 32 - 40 A
V24 208-240 V BCA4 - 40V-24 AC coil contactor 32 - 40 A
V47 480 V BCA4 - 40V-47 AC coil contactor 32 - 40 A
V56 575 V BCA4 - 40V-56 AC coil contactor 32 - 40 A
V18 120 V BCA - 105V-18 AC coil contactor 50 - 105 A
V24 208-240 V BCA - 105V-24 AC coil contactor 50 - 105 A
V47 480 V BCA - 105V-47 AC coil contactor 50 - 105 A
V56 575 V BCA - 105V-56 AC coil contactor 50 - 105 A
5. Pilot Device: A = Start & Stop/Reset Pushbutton
E = Reset Pushbutton
6. Enclosure Type: X = NEMA 4X
7. Overload Ampere Range:
Single Phase Class 10 Three Phase Class 10
Code Part Number Description Code Part Number Description Code Part Number Description
RM26 RW27-1D2-U004 2.8 - 4A R23 RW27-1D3-D012 0.8 - 1.2A R36 RW67-2D3-U040 25 - 40A
RM27 RW27-1D2-D063 4 - 6.3A R24 RW27-1D3-D018 1.2 - 1.8A R37 RW67-1D3-U050 32 - 50A
RM28 RW27-1D2-U008 5.6 - 8A R25 RW27-1D3-D028 1.8 - 2.8A R38 RW67-2D3-U050 32 - 50A
RM29 RW27-1D2-U010 7 - 10A R26 RW27-1D3-U004 2.8 - 4.0A R39 RW67-2D3-U057 40 - 57A
RM30 RW27-1D2-D125 8 - 12.5A R27 RW27-1D3-D063 4.0 - 6.3A R40 RW67-2D3-U063 50 - 63A
RM31 RW27-1D2-U015 10 - 15A R28 RW27-1D3-U008 5.6 - 8.0A R41 RW67-2D3-U070 57 - 70A
RM32 RW27-1D2-U017 11 - 17A R29 RW27-1D3-U010 7.0 - 10A R42 RW67-2D3-U080 63 - 80A
RM33 RW27-1D2-U023 15 - 23A R30 RW27-1D3-D125 8.0 - 12.5A R43 RW117-1D3-U080 63 - 80A
RM34 RW27-1D2-U032 22 - 32A R31 RW27-1D3-U015 10 - 15A R44 RW117-1D3-U097 75 - 97A
RM35 RW67-1D2-U040 25 - 40A R32 RW27-1D3-U017 11 - 17A R45 RW117-1D3-U112 90 - 112A
RM36 RW67-2D2-U040 25 - 40A R33 RW27-1D3-U023 15 - 23A
RM37 RW67-1D2-U050 32 - 50A R34 RW27-1D3-U032 22 - 32A
RM38 RW67-2D2-U050 32 - 50A R35 RW67-1D3-U040 25 - 40A
102
Industrial Control Products 4.3
www.pamensky.com
PESW - Table of Products115V - Single Phase
Electrical Data Mechanical Data Purchasing Data
Overload
Range
(A)
Max.
Motor
(HP)
Coil
VoltageFrame
Degree of
Protection
Dimensions
H x W xD (in)WEG Part Number List Price
7 - 10 0.5 120 V 04 NEMA 4X 7.3 x 4.1 x 4.4 PESWS-9V18AX-RM29 $123
10 - 15 0.75 120 V 04 NEMA 4X 7.3 x 4.1 x 4.4 PESWS-12V18AX-RM31 135
11 - 17 1 120 V 04 NEMA 4X 7.3 x 4.1 x 4.4 PESWS-18V18AX-RM32 141
15 - 23 2 120 V 04 NEMA 4X 7.3 x 4.1 x 4.4 PESWS-25V18AX-RM33 148
25 - 40 3 120 V 06 NEMA 4X 8.3 x 4.7 x 5.0 PESWS-40V18AX-RM35 289
25 - 40 3 120 V 08 NEMA 4X 11.0 x 7.1 x 5.6 PESWS-50V18AX-RM36 504
40 - 57 5 120 V 08 NEMA 4X 11.0 x 7.1 x 5.6 PESWS-50V18AX-RM39 539
208-230V - Single Phase
Electrical Data Mechanical Data Purchasing Data
Overload
Range
(A)
Max.
Motor
(HP)
Coil
VoltageFrame
Degree of
Protection
Dimensions
H x W xD (in)WEG Part Number List Price
5.6 - 8 1 230 V 04 NEMA 4X 7.3 x 4.1 x 4.4 PESWS-9V24AX-RM28 $123
8 - 12.5 1.5 230 V 04 NEMA 4X 7.3 x 4.1 x 4.4 PESWS-9V24AX-RM30 123
10 - 15 2 230 V 04 NEMA 4X 7.3 x 4.1 x 4.4 PESWS-12V24AX-RM31 135
11 - 17 3 230 V 04 NEMA 4X 7.3 x 4.1 x 4.4 PESWS-18V24AX-RM32 141
15 - 23 5 230 V 04 NEMA 4X 7.3 x 4.1 x 4.4 PESWS-25V24AX-RM33 148
25 - 40 7.5 230 V 08 NEMA 4X 11.0 x 7.1 x 5.6 PESWS-50V24AX-RM36 504
32 - 50 10 230 V 08 NEMA 4X 11.0 x 7.1 x 5.6 PESWS-65V24AX-RM38 539
208-230V - Three Phase
Electrical Data Mechanical Data Purchasing Data
Overload
Range
(A)
Max.
Motor
(HP)
Coil
VoltageFrame
Degree of
Protection
Dimensions
H x W xD (in)WEG Part Number List Price
1.8 - 2.8 0.75 230 V 04 NEMA 4X 7.3 x 4.1 x 4.4 PESW-9V24AX-R25 $139
2.8 - 4 1 230 V 04 NEMA 4X 7.3 x 4.1 x 4.4 PESW-9V24AX-R26 139
4 - 6.3 1.5 230 V 04 NEMA 4X 7.3 x 4.1 x 4.4 PESW-9V24AX-R27 139
5.6 - 8 2 230 V 04 NEMA 4X 7.3 x 4.1 x 4.4 PESW-9V24AX-R28 139
7 - 10 3 230 V 04 NEMA 4X 7.3 x 4.1 x 4.4 PESW-9V24AX-R29 139
11 - 17 5 230 V 04 NEMA 4X 7.3 x 4.1 x 4.4 PESW-18V24AX-R32 161
15 - 23 7.5 230 V 04 NEMA 4X 7.3 x 4.1 x 4.4 PESW-25V24AX-R33 169
15 - 23 7.5 230 V 06 NEMA 4X 8.3 x 4.7 x 5.0 PESW-32V24AX-R33 226
22 - 32 10 230 V 06 NEMA 4X 8.3 x 4.7 x 5.0 PESW-32V24AX-R34 226
25 - 40 15 230 V 06 NEMA 4X 8.3 x 4.7 x 5.0 PESW-40V24AX-R35 340
25 - 40 15 230 V 08 NEMA 4X 11.0 x 7.1 x 5.6 PESW-50V24AX-R36 622
32 - 50 15 230 V 08 NEMA 4X 11.0 x 7.1 x 5.6 PESW-50V24AX-R38 622
40 - 57 20 230 V 08 NEMA 4X 11.0 x 7.1 x 5.6 PESW-65V24AX-R39 637
57 - 70 25 230 V 08 NEMA 4X 11.0 x 7.1 x 5.6 PESW-80V24AX-R41 691
63 - 80 30 230 V 10 NEMA 4X 14.2 x 9.9 x 6.6 PESW-95V24AX-R43 836
90 - 112 40 230 V 10 NEMA 4X 14.2 x 9.9 x 6.6 PESW-105V24AX-R45 871
102
Industrial Control Products4.4
www.pamensky.com
460V - Three Phase
Electrical Data Mechanical Data Purchasing Data
Overload
Range
(A)
Max.
Motor
(HP)
Coil
VoltageFrame
Degree of
Protection
Dimensions
H x W xD (in)WEG Part Number List Price
1.2 - 1.8 1 460V 04 NEMA 4X 7.3 x 4.1 x 4.4 PESW-9V47AX-R24 $139
1.8 - 2.8 1.5 460V 04 NEMA 4X 7.3 x 4.1 x 4.4 PESW-9V47AX-R25 139
2.8 - 4 2 460V 04 NEMA 4X 7.3 x 4.1 x 4.4 PESW-9V47AX-R26 139
4 - 6.3 3 460V 04 NEMA 4X 7.3 x 4.1 x 4.4 PESW-9V47AX-R27 139
5.6 - 8 5 460V 04 NEMA 4X 7.3 x 4.1 x 4.4 PESW-9V47AX-R28 139
8 - 12.5 7.5 460V 04 NEMA 4X 7.3 x 4.1 x 4.4 PESW-12V47AX-R30 145
11 - 17 10 460V 04 NEMA 4X 7.3 x 4.1 x 4.4 PESW-18V47AX-R32 161
15 - 23 15 460V 04 NEMA 4X 7.3 x 4.1 x 4.4 PESW-25V47AX-R33 169
15 - 23 15 460V 06 NEMA 4X 8.3 x 4.7 x 5.0 PESW-32V47AX-R33 226
22 - 32 20 460V 06 NEMA 4X 8.3 x 4.7 x 5.0 PESW-32V47AX-R34 226
25 - 40 25 460V 06 NEMA 4X 8.3 x 4.7 x 5.0 PESW-40V47AX-R35 340
32 - 50 30 460V 08 NEMA 4X 11.0 x 7.1 x 5.6 PESW-50V47AX-R38 622
40 - 57 40 460V 08 NEMA 4X 11.0 x 7.1 x 5.6 PESW-65V47AX-R39 637
57 - 70 50 460V 08 NEMA 4X 11.0 x 7.1 x 5.6 PESW-80V47AX-R41 691
63 - 80 60 460V 10 NEMA 4X 14.2 x 9.9 x 6.6 PESW-95V47AX-R43 836
75 - 97 75 460V 10 NEMA 4X 14.2 x 9.9 x 6.6 PESW-105V47AX-R44 871
575V - Three Phase
Electrical Data Mechanical Data Purchasing Data
Overload
Range
(A)
Max.
Motor
(HP)
Coil
VoltageFrame
Degree of
Protection
Dimensions
H x W xD (in)WEG Part Number List Price
1.2 - 1.8 1 575V 04 NEMA 4X 7.3 x 4.1 x 4.4 PESW-9V56AX-R24 $139
1.8 - 2.8 1.5 575V 04 NEMA 4X 7.3 x 4.1 x 4.4 PESW-9V56AX-R25 139
2.8 - 4 3 575V 04 NEMA 4X 7.3 x 4.1 x 4.4 PESW-9V56AX-R26 139
4 - 6.3 5 575V 04 NEMA 4X 7.3 x 4.1 x 4.4 PESW-9V56AX-R27 139
7 - 10 7.5 575V 04 NEMA 4X 7.3 x 4.1 x 4.4 PESW-9V56AX-R29 139
8 - 12.5 10 575V 04 NEMA 4X 7.3 x 4.1 x 4.4 PESW-12V56AX-R30 145
11 - 17 15 575V 04 NEMA 4X 7.3 x 4.1 x 4.4 PESW-18V56AX-R32 161
15 - 23 20 575V 06 NEMA 4X 8.3 x 4.7 x 5.0 PESW-32V56AX-R33 226
22 - 32 25 575V 06 NEMA 4X 8.3 x 4.7 x 5.0 PESW-32V56AX-R34 226
25 - 40 30 575V 08 NEMA 4X 11.0 x 7.1 x 5.6 PESW-50V56AX-R36 622
32 - 50 40 575V 08 NEMA 4X 11.0 x 7.1 x 5.6 PESW-50V56AX-R38 622
40 - 57 50 575V 08 NEMA 4X 11.0 x 7.1 x 5.6 PESW-65V56AX-R39 637
57 - 70 60 575V 08 NEMA 4X 11.0 x 7.1 x 5.6 PESW-80V56AX-R41 691
63 - 80 75 575V 10 NEMA 4X 14.2 x 9.9 x 6.6 PESW-95V56AX-R43 836
PESW - Table of Products
102
Industrial Control Products 4.5
www.pamensky.com
PESW - Wiring Diagrams
Three phase D.O.L. Starter
Control circuit with phase to phase coil supply
Figure 1
Single-phase D.O.L Starter
Control circuit with separate coil supply
Figure 2
When using 24V, 48V, 110V, etc. on the
Part Number, WEG D.O.L. starters (DLW) will be factory-connected, as per
wiring diagrams of figure 2, that is, with control circuit to be connected
through a separate coil supply.
When using 230V, 400V, 500V, and 690V on the
Part Number, WEG D.O.L. starters (DLW) will
be factory-connected, as per wiring diagrams of figure 1, that is, with phase to
phase coil suplly.
For the voltages with phase to phase coil supply, contact WEG.
Note: When using remote control, disconnect the circuit at the points marked with the “x” in figures 1 and 2 and connect the external devices (Thermostat, pushbutton, etc),
as indicated with dotted lines.
Pilot Devices
102
Industrial Control Products4.6
www.pamensky.com
PESW - Dimensions
Dimensions in inches.
* For wall mounting on starters size 08 and 10, four screws with the following characteristics should be used: • Pan, dome or rounded shaped head;• Starter size 08:
• Screws size 1/4 (or M6 – ISO Standard);• Dimensions: diameter thread shall be maximum 1/4 in. and diameter head shall be maximum 15/64 in.
• Starter size 10: • Screws size 12 (or M5 – ISO Standard);
• Dimensions: diameter thread shall be maximum 0.236 in. and diameter head shall be maximum 0.394 in.
Frame øA B C D E
Provision for cable gland fi tting
Top Bottom Back
Size 04 0.2 7.1 4.4 4.1 7.3 2 x 1/2” 2 x 1/2” ø0.7
Size 06 0.3 8.1 5.0 4.7 8.3 2 x 1/2” and 3/4” 2 x 1/2” and 3/4” ø0.9
Size 08 0.2 10.8 5.6 7.1 11.0 2 x 3/4” and 1” 2 x 3/4” and 1” N/A *
Size 10 0.3 14.0 6.6 9.9 14.2 1 x 1” and 1 1/4” 1 x 1” and 1 1/4” N/A *
102
Industrial Control Products 4.7
www.pamensky.com
Other Starter Options
ESW Series NEMA 1 Non-Combination Starters
• High horsepower ratings in three compact sizes
• NEMA type 1 metallic lift-off enclosure with
knockouts
• Bimetallic ambient compensated overload relays
• Easy addition of pilot devices for fi eld modifi cation
• Manual RESET plunger is provided as standard
feature on all models
Customized Starter Solution
V.J. Pamensky Canada Inc. has a Toronto based panel
shop to design and build custom solutions for motor
control applications. Customized NEMA 4 starters
with Emergency Stop, Start-Stop and control options
can be built quickly and to fi t the demands of different
applications.
Explosion Proof Manual Motor Starters
• Suitable for Hazardous Areas: Class I, Groups C &
D - Class II, Groups E, F, G
• Motor Control
• Circuit Disconnect
• Short Circuit Protection up to 10 kA @ 600 VAC
• Thermal Overload Protection Class 10
• Control Devices: Start & Stop / Reset
102
Industrial Control Products4.8
www.pamensky.com
CWC Miniature ContactorsThe CWC Series miniature contactor features more horsepower for its size than any other
miniature contactor on the market. The CWC’s compact dimensions for its current rating, up
to 25A, AC-3 utilization category, allows it to take up less space inside electrical enclosures
while still running motors up to 10HP @ 575V. The dimensions remain the same whether the
coil voltage is AC or DC making panel design and assembly easier. DC models feature low
consumption coils allowing the CWC to be operated directly from a PLC without interface
relays.
The following confi gurations are available “off-the-shelf.”
• 3 Pole Normally Open Power Contacts
with one built-in Auxiliary Contact (Can be
Normally Open or Normally Closed)
• 3 Pole Normally Open Reversing Contactors rated AC-4 Utilization Category
• 4 Pole Power Contacts (four Normally Open, or two Normally Open and two Normally
Closed)
• Control Relay
An extensive lineup of modular and tool-free accessories makes the CWC Series the most
fl exible and easy-to-use miniature contactor available today.
Features
• Rated up to 10 HP @ 575V
• Direct mounting to the WEG RW17D
overload relay and MPW25 manual motor
protector with ECCMP-C0 accessory
• Frame size remains the same for AC and
DC coil contactors
• Heavy-duty operation
• Tool-free DIN rail mounting
• Complete line of snap-on accessories
102
Industrial Control Products 4.9
www.pamensky.com
CWC - Part Number Specifi cation-
5
V18
2
16
4
30
3
10
1
CWC
1. CWC Miniature Contactor
2. Frame Rating: Blank: Control Relay (Ith = 10Amps)
07: 7Amps
09: 9Amps
12: 12Amps
16: 16Amps
25: 25Amps
3. Auxiliary Contacts: 00: None
10: 1 NO
01: 1 NC
4. Power Pole: 00: Control Relay (4 auxiliary terminals)
30: CWC0 with 3 NO Power Poles
22: CWC0 with 2 NO + 2 NC Power Poles
40: CWC0 with 4 NO Power Poles
5. Coil Voltage: VAC Coil VDC Coil (Standard Consumption) VDC Coil (Low Consumption)
Description Code Description Code Description Code
24Vac 60Hz V04 24Vdc C03 24Vdc L03
120Vac 60Hz V18 110Vdc C12
208-240Vac 60Hz V24
480Vac 60Hz V47
600Vac 60Hz V56
102
Industrial Control Products4.10
www.pamensky.com
CWC Miniature Contactors - Table of Products
Replace ‘X’ with code for AC Coil Voltage Code Selection
60 Hz 120V 208-240V
CODE V18 V24
50 Hz 110V -
Replace ‘X’ with code for AC Coil Voltage Code Selection
60 Hz 120V 208-240V 480V 600V
CODE V18 V24 V47 V56
50 Hz 110V - 400-415V -
Three Pole Miniature Contactors with AC Coil
Electrical Data Mechanical Data Purchasing Data
Current
(A)
Maximum Applicable Motor (HP)Auxiliary Contacts Weight
(lb)Part Number List PriceSingle Phase Three Phase
115V 230V 200V 230V 460V 575V NO NC
7 1/3 3/4 1 1/2 1 1/2 5 5 1 0 0.43 CWC07-10-30* $29
7 1/3 3/4 1 1/2 1 1/2 5 5 0 1 0.43 CWC07-01-30* 29
9 1/3 1 2 3 5 7 1/2 1 0 0.43 CWC09-10-30* 31
9 1/3 1 2 3 5 7 1/2 0 1 0.43 CWC09-01-30* 31
12 1/2 2 3 3 7 1/2 7 1/2 1 0 0.43 CWC12-10-30* 32
12 1/2 2 3 3 7 1/2 7 1/2 0 1 0.43 CWC12-01-30* 32
16 1 2 3 5 10 10 1 0 0.43 CWC16-10-30* 33
16 1 2 3 5 10 10 0 1 0.43 CWC16-01-30* 33
25 1 1/2 3 5 7 1/2 15 15 0 0 0.44 CWC25-00-30* 42
Miniature Control Relay with AC Coils
Electrical Data Purchasing Data
Current
(A)Rating
Auxiliary ContactsPart Number List Price
N.O. N.C.
10 A600, Q600 2 2 CAW04R422X $30
10 A600, Q600 3 1 CAW04R431X 30
10 A600, Q600 1 3 CAW04R413X 30
10 A600, Q600 4 0 CAW04R440X 30
10 A600, Q600 0 4 CAW04R404X 30
102
Industrial Control Products 4.11
www.pamensky.com
CWC Miniature Contactors - Technical DataPart number CWC07 CWC09 CWC012 CWC016 CWC025 CWCA0
Standards IEC/EN 60 947. DIN VDE 0660. UL. CSA
Rated insulation voltage Ui
IEC/EN 60 947. DIN VDE 0660 690 V
600 VUL. CSA
Rated impuse withstand voltage Uimp
4kV
Rated operational frequency 25 - 400 Hz
Degree of protection
Main circuits IP20
IP20Control circuits and auxiliary contacts
Ambient temperature
Operating temperature
Storage temperature-25oC to +55oC
-55oC to +80oC
Altitude
Normal values
90 % Ie / 80 % U
e
80 % Ie / 75 % U
e
to 3000 m
3000 to 4000 m
4000 to 5000 m
Overvoltage category / Pollution degree III / 3
Climatic proofi ng IEC 60 680-2
Pole number of main circuits 3 4
Rated operational voltage Ue
690V 690 V
Conv. thermal current Ith
at < 55oC rated operational current Ie / AC-1
18 A 20 A 22 A 22 A 32 A 10 A
Rated operational current Ie AC-4 (U
e ≤ 440V) 2.8 3.5 4.5 5 9 -
AC-3 Utilization Category
Rated operational power
220/230 V kW / hp
380 V kW / hp
400/415 V kW / hp
440 V kW / hp
500 V kW / hp
690 V kW / hp
1.5 / 2
3 / 4
3 / 4
3.7 / 5
3.7 / 5
3.7 / 5
2.2 / 3
4 / 5
4.5 / 6
4.5 / 6
4.5 / 6
5.5 / 7.5
3 / 4
5.5 / 7.5
5.5 / 7.5
5.5 / 7.5
5.5 / 7.5
7.5 / 10
4 / 5
7.5 / 10
7.5 / 10
7.5 / 10
7.5 / 10
7.5 / 10
5.5 / 7.5
11 / 15
11 / 15
11 / 15
11 / 15
11 / 15
-
-
-
-
-
-
Maximum numbers of auxiliary contacts 5 2 4
Short circuit rating max. fuse gL-gG (A) 20 20 25 25 35 10
Maximum electrical operations per hour
AC-1 Ops/h
AC-3 Ops/h
AC-4 Ops/h
no load Ops/h
300
600
300
2500
-
-
-
2500
Mechanical lifespan Ops x 106 10 3 10
Electrical lifespan (AC-3) Ops x 106 1.4 1.3 1.2 1.1 0.6 -
Rated operational current Ie
AC-15
220-230 V A - - - - - 10
380-400 V A - - - - - 6
415 V A - - - - - 5
500 V A - - - - - 4
DC-13
24 V A - - - - - 6
48 V A - - - - - 4
110 V A - - - - - 2
220 V A - - - - - 0.7
Control circuit reliability -U
e min=17 V
Ie min= 5 mA
Terminal capacity
1 or 2 x (0.5...2.5)1 or 2 x (1...2.5)
1 or 2 x (2.5...6.0)1 or 2 x (0.5...2.5)
Tightening torque N.m 1...1.5 1.8 1...1.5
102
Industrial Control Products4.12
www.pamensky.com
CWC Miniature Contactors - Technical Data
Control circuit
Part number CWC07 CWC09 CWC012 CWC016 CWC025 CWCA0
Coil consumption AC
Pick-up VA 30 58 30
Cos j 0.8 0.8 0.8
Sealing VA 2...3 4.5...5.8 2...3
Cos j 0.27 0.27 0.27
Operation time Closing / Opening (AC) ms 8...20 / 6...13 13...16 / 13.5...17 8...20 / 6...13
Coils rated voltage V 12-660VAC / 12-440VDC 12-660VAC 12-660VAC / 12-440VDC
Coil operational limits 0.85...1.1
Bifrequency coilsPick-up xUs 0.5...0.8
Drop-out xUs 0.2...0.6
Timing Relay
Rated insulation voltage (Ui ) V 300
Supply voltage (Ue )
1 – 2
terminals
24...240 VDC/VAC 50/60 Hz (TEC0)
24...60 VDC/VAC 50/60 Hz (TDC0)
100...240 VDC/VAC 50/60 Hz (TDC0)
220-240 VAC 50/60Hz (TETC0)
110-130 VAC 50/60Hz (TETC0)
24-28 VAC 50/60Hz (TETC0)
Control Voltage (Uc )
only TDC0 - pg 18
2 – B1
terminals
24...60 VDC/VAC 50/60 Hz (TDC0)
100...240 VDC/VAC 50/60 Hz (TDC0)
Voltage operational limits0.85...1.1 x Uc (VAC)
0.8...1.25 x Uc (VDC)
Consumption mA ≤ 5
Minimum time for Reset (Recovery time) ms 650
Minimum control time (only TDC0) ms 50
Setting accuracy (% of the full scale value) % +/-5
Repeat Accuracy % +/-1
Changeover time Y - Δ ms 50
Auxiliary contact block BFC
Terminal capacity
Number of conductors and Cross section
(min. and max.)
Flexible without cable lug (mm2) 2x (0.5...2.5)
Flexible without cable lug (mm2) 2x (0.75...1.5)
AWG Cables (12...22)
Tightening torque Nm 08...1.5Nm
Conventional thermal current (lth) A 10
Rated operational current (Ie) AC - 15
A6/4(220/240V). 3/2(380/440V). 2(500V)
Rated operational current (Ie) DC - 13 1.5(24V). 0.5(60V). 0.2(220-240V)
102
Industrial Control Products 4.13
www.pamensky.com
CWM Standard ContactorsThe CWM general-purpose contactor line has been designed to take into consideration
industrial duty and reliability.
Rated for inductive loads up to 800A or 440kW @380/400V, WEG can offer the suitable
contactor for your application.
CWM contactors allow total panel space optimization, with only a few compact frame
sizes from 4 to 440kW @ 400/415V. Reducing inventory is a “snap” with CWM’s common
accessories. For example, side-mounted auxiliary contact blocks are the same from 9 to
300A (AC-3) @ 440V.
Designed for extended mechanical and electrical life, dependable switching in even the most
heavy-duty applications can be achieved. No matter how demanding the application, all
WEG contactors are tested and approved to be used under Type 1 and Type 2 short circuit
coordination. Ensuring global acceptance, all components conform to UL508 (USA and
Canada), IEC60947 and CE.
Features
• General purpose motor applications
• Fractional power through 600HP @ 460V
• Compact frame sizes
• Panel mountable or 35mm DIN rail up to
75HP @ 460V
• Built-in auxiliary contacts up to 10HP @
460V
• Front and side mountable auxiliary contact
blocks
• IP20 Finger-touch protection
• Wide coil voltage selection AC or DC
• AC/DC coils with electronic modules
available from 100HP and up
• Replaceable main contacts for entire line
102
Industrial Control Products4.14
www.pamensky.com
CWM - Part Number Specifi cation-
5
V18
2
18
4
30
3
10
1
CWM
1. CWM Contactor CWM: Contactor up to 300ACWME: Contactor 400A and above
2. Frame Rating: 9: 9Amps
12: 12Amps
18: 18Amps
25: 25Amps
32: 32Amps
40: 40Amps
50: 50Amps
65: 65Amps
80: 80Amps
95: 95Amps
105: 105Amps
112: 112Amps
150: 150Amps
180: 180Amps
250: 250Amps
300: 300Amps
400: 400Amps
600: 630Amps
800: 800Amps
3. Auxiliary Contacts: 00: None
10: 1 NO
01: 1 NC
11: 1 NO + 1 NC
22: 2 NO + 2 NC
4. Power Pole: 30: 3 NO Power Poles
20: 2 NO Power Poles
5. Coil Voltage: VAC Coil (CWM9 to CWM105) VDC Coil (CWM9 to CWM105) VAC / VDC Coil (CWM112 to CWME800)
Description Code Description Code Description Code
24Vac 60Hz V04 24Vdc (CWM9…CWM25) C03 24-28Vac/Vdc (CWM112…CWM300) E02
120Vac 60Hz V18 24-28Vdc (CWM32…CWM105) C34 110-130Vac/Vdc (CWM112…CWM300) E10
208-240Vac 60Hz V24 110Vdc (CWM9…CWM25) C12 208-250Vac/Vdc (CWM112…CWM300) E13
480Vac 60Hz V47 110-130Vdc (CWM32…CWM105) C40 430-500Vac/Vdc (CWM112…CWM300) E42
600Vac 60Hz V56 100-127Vac/Vdc (CWME630…CWME800) E35
100-240Vac/Vdc (CWME400) E36
200-240Vac/Vdc (CWME630…CWME800) E39
440-575Vac (CWME400…CWME800) D82
102
Industrial Control Products 4.15
www.pamensky.com
CWM Standard Contactors - Table of ProductsThree Pole Contactors with AC Coil
Electrical Data Mechanical Data Purchasing Data
Current
(A)
Maximum Applicable Motor (HP)Auxiliary Contacts Weight
(lb)Part Number List PriceSingle Phase Three Phase
115V 230V 200V 230V 460V 575V NO NC
9 1/2 1.5 3 3 5 7 1/2 1 0 0.65 CWM9-10-30* $42
9 1/2 1.5 3 3 5 7 1/2 0 1 0.65 CWM9-01-30* 42
12 3/4 2 3 3 7 1/2 10 1 0 0.65 CWM12-10-30* 55
12 3/4 2 3 3 7 1/2 10 0 1 0.65 CWM12-01-30* 55
18 1 3 5 5 10 15 1 0 0.65 CWM18-10-30* 60
18 1 3 5 5 10 15 0 1 0.65 CWM18-01-30* 60
25 2 5 7 1/2 7 1/2 15 15 0 0 0.65 CWM25-00-30* 71
25 2 5 7 1/2 7 1/2 15 15 1 1 0.65 CWM25-11-30* 71
32 3 5 10 10 20 25 0 0 1.15 CWM32-00-30* 101
32 3 5 10 10 20 25 1 1 1.15 CWM32-11-30* 101
40 3 7.5 10 15 30 25 0 0 1.19 CWM40-00-30* 143
40 3 7.5 10 15 30 25 1 1 1.19 CWM40-11-30* 143
50 3 10 15 15 40 40 0 0 2.44 CWM50-00-30* 163
50 3 10 15 15 40 40 1 1 2.44 CWM50-11-30* 163
65 5 10 20 20 50 50 0 0 2.47 CWM65-00-30* 182
65 5 10 20 20 50 50 1 1 2.47 CWM65-11-30* 182
80 7 1/2 15 20 25 50 60 0 0 2.49 CWM80-00-30* 233
80 7 1/2 15 20 25 50 60 1 1 2.49 CWM80-11-30* 233
95 7 1/2 15 25 30 60 75 0 0 3.20 CWM95-00-30* 284
95 7 1/2 15 25 30 60 75 1 1 3.20 CWM95-11-30* 284
105 10 20 30 40 75 75 0 0 3.24 CWM105-00-30* 331
105 10 20 30 40 75 75 1 1 3.24 CWM105-11-30* 331
150 - - 50 60 125 150 2 2 5.60 CWM150L322X 658
180 - - 60 75 150 200 2 2 8.91 CWM180L322X 909
250 - - 75 100 200 250 2 2 13.54 CWM250L322X 1,321
300 - - 100 125 250 350 2 2 13.54 CWM300L322X 1,514
400 - - 125 150 300 300 2 2 call CWME400L322X 2,082
630 - - 150 200 400 400 2 2 call CWME630L322X 3,158
800 - - 200 300 600 600 2 2 call CWME800L322X 4,620
Replace ‘X’ with code for AC Coil Voltage Code Selection for Contactors CWM9 to CWM105
60 Hz 24V 48V 120V 208-240V 480V 600V
CODE V04 V10 V18 V24 V47 V56
50 Hz - 42V 110V - 400-415V 500V
Replace ‘X’ with AC/DC Coil voltage code selection for Contactors CWM150, 180, 250, 300
Voltage 110-130Vac/Vdc 208-250Vac/Vdc
CODE E10 E13
Mounting on CWM112-300 CWM112-300
Replace ‘X’ with AC/DC Coil voltage code selection for Contactors CWM400, 630, 800
Voltage 100-240Vac/100-220Vdc 100-127Vac/100-110Vdc 200-240Vac/200-220Vdc 440-575Vac
CODE E36 E35 E39 D82
Mounting on CWME400 CWME630-800 CWME630-800 CWME400-800
102
Industrial Control Products4.16
www.pamensky.com
CWM Standard Contactors - Accessories
Maximum # of added auxiliary contacts per contactor frame size: Note that side mountable version has 2 aux. contacts per block.CWM9…25 = 4 aux. contacts; CWM32…40 = 6 aux. contacts; CWM50…300E = 8 aux. contacts.
Auxiliary contact blocks for CWM9 to CWME800
• Terminal markings to EN 50 005 and EN 50 012
• Positive driven contacts in accordance with IEC/EN 60947-4-1 resp. IEC/EN60947-5-1
Description For ContactorAuxiliary
Part Number List PriceNO NC
Front Mounting CWM9…105 1 0 BCXMF10 $5
Front Mounting CWM9…105 0 1 BCXMF01 5
Side Mounting CWM9…300 1 1 BCXML11 15
Side Mounting CWM9…300 2 0 BCXML20 15
Side Mounting CWM400…CWM800 1 1 BCXML11 CWME800 44
Side Mounting, Second Block CWM400…CWM800 1 1 BCXMRL11 CWME800 44
For CWM9…CWM105 the mechanical interlock can be used to interlock different frame sizes. For CWM112…CWM300, the mechanical interlock has to be used with contactors that have the same mechanical frame size.For BLIM CWME800, a metal mount base is provided with this accessory for an accurate assembling of the contactors.
Mechanical Interlock
Description For ContactorAuxiliary
Part Number List PriceNO NC
Side mounted between two contactors CWM9…105 0 0 BLIM 9-105 $30
Side mounted between two contactors CWM112…CWM300 0 0 BLIM 112-300 54
Side mounted between two contactors CWM400 0 0 BLIM CWME400 44
Bottom mounted between two contactors CWM630…CWM800 0 0 BLIM CWME800 1424
Surge Suppressors
Description For Contactor Voltage Range Part Number List Price
Limits switching transients from contactor pick-up CWM9...40 130...250V CWMBAMRC6 $23
Limits switching transients from contactor pick-up CWM50...105 130...250V CWMBAMRC9 23
102
Industrial Control Products 4.17
www.pamensky.com
CWM Standard Contactors - AccessoriesIndividual spare coils
Description Part Number List Price
AC Coil CWM9....25. CWMC25 CWMBCA425X $10
AC Coil CWM32...40. CWMC32 CWMBCA440X 16
AC Coil CWM50...105. CWMC50...65 CWMBCA105X 22
AC Coil CWM112 CWMBCA112X 24
AC Coil CWM180 CWMBCA180X 44
AC Coil CWM250 CWMBCA250X 60
Dual-Voltage Coils AC/DC (contactors with electronic module) CWM112...150 CWMBCE-150X 28
Dual-Voltage Coils AC/DC (contactors with electronic module) CWM180 CWMBCE-180X 44
Dual-Voltage Coils AC/DC (contactors with electronic module) CWM250...300 CWMBCE-300X 74
Dual-Voltage Coils AC/DC (contactors with electronic module) CWME400 CWMEBCE-400X 492
Dual-Voltage Coils AC/DC (contactors with electronic module) CWME630...800 CWMEBCE-800X 600
Replace ‘X’ with AC/DC Coil voltage code selection for Contactors CWM150, 180, 250, 300
Voltage 110-130Vac/Vdc 208-250Vac/Vdc
CODE E10 E13
Mounting on CWM112-300 CWM112-300
Replace ‘X’ with AC/DC Coil voltage code selection for Contactors CWM400, 630, 800
Voltage 100-240Vac/100-220Vdc 100-127Vac/100-110Vdc 200-240Vac/200-220Vdc 440-575Vac
CODE E36 E35 E39 D82
Mounting on CWME400 CWME630-800 CWME630-800 CWME400-800
Replace ‘X’ with code for AC Coil Voltage Code Selection for Contactors CWM9 to CWM105
60 Hz 24V 48V 120V 208-240V 480V 600V
CODE V04 V10 V18 V24 V47 V56
50 Hz - 42V 110V - 400-415V 500V
102
Industrial Control Products4.18
www.pamensky.com
CWM Standard Contactors - Technical DataGeneral Ratings - CWM9 to CWM105
Type CWM9 CWM12 CWM18 CWM25 CWM32 CWM40 CWM50 CWM65 CWM80 CWM95 CWM105
StandardsDevices according to International Standards IEC 60947-1 / 60947-4-1, European Standards EN 60947-1 / 60947-4-1,
Underwriters Laboratories - UL 508; CSA C.22.2/14; VDE 0660/102
Rated Insulation Volt-
age Ui
Acc. IEC; VDE 0660
Acc. UL; CSA
[V]
[V]
1000
600
Rated Impulse Voltage
Uimp
Acc. IEC60947-1[kV] 6 8
Rated Operating
Frequency[Hz] 25…400
Degree of Protection
Main terminals
Coil terminals
Auxiliary terminals
Protection against direct contact Acc. VDE 0160 - Part. 100
IP20 IP10
IP20
IP20
Ambient Temperature
Storage
Operating
-55 to +80oC (-67 to +176oF)
-25 to +55oC (-13 to +131oF)
Altitude
Up to 1,500m
Other altitudes
Nominal values
See graphic on page 94
Pollution Degree 3
Climatic Withstand According to IEC 68-2
Mounting 35mm rail Acc. DIN EN 50 022
Vibration Resistance
(5 to 200 Hz)
Contactor open
Contactor closed at Uc
[g]
[g]
3
6
3
6
3
6
7.5
8
8
12
8
12
4.5
9
4.5
9
4.5
9
5
7
5
7
Mechanical Endurance
AC CoilMillion
ops.10
Electrical Endurance
AC-3
Million
ops.1.8 1.6 1.2 1.3 1.2 1.2 1.1 1.3 1.1 1.1 1
Shock Resistance
(1/2 sin wave = 11ms)
Contactor open
Contactor closed at Uc
[g]
[g]
8
12
8
12
8
12
8
12
7
12
7
12
6
10
6
10
6
10
6
10
6
10
Weight
AC Coil
[kg]
[lb]
0.30
0.65
0.30
0.65
0.30
0.65
0.30
0.65
0.52
1.15
0.54
1.19
1.11
2.44
1.12
2.47
1.13
2.49
1.45
3.20
1.47
3.24
Terminal Capacity Cross / Slotted Combination Allen Head
Fine - Stranded with
sleeve
Top
[mm2]2x0.5-2.5 2x0.5-2.5 2x0.5-2.5 2x1-2.5 0.75-16 0.75-16 1-35 1-35 1-35 1.5-50 1.5-50
Bot-
tom
[mm2]
or 2x2.5-6 or 2x2.5-6 or 2x2.5-6 or 2x2.5-10 1.0-16 1.0-16 2.5-35 2.5-35 2.5-35 4-35 4-35
Coarse - Stranded /
Solid
Top
[mm2]2x1-2.5 2x1-2.5 2x1-2.5 2x1-2.5 1-16 1-16 1.5-35 1.5-35 1.5-35 2.5-50 2.5-50
Bot-
tom
[mm2]
or 2x2.5-6 or 2x2.5-6 or 2x2.5-6 or 2x2.5-10 1.5-16 1.5-16 6-35 6-35 6-35 6-35 6-35
Stranded / Solid (UL
/ CSA)
Top
[AWG]2x20-12 2x20-12 2x20-12 2x18-12 18-6 18-6 16-2 16-2 16-2 16-1 16-1
Bot-
tom
[AWG]
or 2x12-10 or 2x12-10 or 2x12-10 or 2x12-8 16-6 16-6 14-2 14-2 14-2 10-2 10-2
Drive Size Philips #2 5/32” (4mm.)
Tightening Torquelb-in
(Nm)
8.9...15
(1...1.7)
8.9...15
(1...1.7)
8.9...15
(1...1.7)
14.2...26.6
(1.6...3)
22.1...35..4
(2.5...4)
22.1...35..4
(2.5...4)
35.4...53.1
(4...6)
35.4...53.1
(4...6)
35.4...53.1
(4...6)
44.3...57.5
(5...6.5)
44.3...57.5
(5...6.5)
Operating Position see next page
102
Industrial Control Products 4.19
www.pamensky.com
CWM Standard Contactors - Technical Data
General Ratings - CWM112 to CWME800
Type CWM112 CWM150 CWM180 CWM250 CWM300 CWME400 CWME630 CWME800
StandardsDevices according to International Standards IEC 60947-1 / 60947-4-1, European Standards EN 60947-1 / 60947-4-1,
Underwriters Laboratories - UL 508; CSA C.22.2/14; VDE 0660/102
Rated Insulation Volt-
age Ui
Acc. IEC; VDE 0660
Acc. UL; CSA
[V]
[V]
1000
600
Rated Impulse Voltage
Uimp
Acc. IEC60947-1
Rated Operating
Frequency
[kV]
[Hz]
8
25…400
Degree of protection
Main terminals
Coil terminals
Auxiliary terminals
Protection against direct contact acc. VDE 0160 - Part. 100
IP00
IP20
IP20
Ambient Temperature
Storage
Operating
-55 to +80oC (-67 to +176oF)
-25 to +55oC (-13 to +131oF)
Altitude
Up to 1,500m
Other altitudes
Nominal values
See graphic on page __ up to 2000m
Pollution Degree 3
Climatic withstand According to IEC 68-2
Mounting Screw to panel
Vibration Resistance
(5 to 200 Hz)
Contactor open
Contactor closed at Uc
[g]
[g]
4
4
Mechanical Endurance
AC CoilMillion
ops.10 5
Electrical Endurance
AC-3
Million
ops.1.1 1.1 1.0 1.0 1.0 0.5
Shock Resistance
(1/2 sin wave = 11ms)
Contactor open
Contactor closed at Uc
[g]
[g]
3
3
Weight
AC/DC Coil - CWM_E
Series only
[kg]
[lb]
2.54
5.60
2.54
5.60
4.04
8.91
6.14
13.54
6.14
13.54
-
-
-
-
-
-
Terminal Capacity
Fine - Stranded with
sleeve [mm2] 2 x (25-70) 2 x (25-70) 2 x (50-120) 2 x (50-150) 2 x (50-150) 1 x 150 1 x 240 1 x 240
AWG wires with end
sleeve
1 x 300
or 2 x 107
1 x 300
or 2 x 107
1 x 300
or 2 x 107
1 x 500
or 2 x 300
1 x 500
or 2 x 300Nº2 30×5 Nº2 50×5 Nº2 60×5
Busbars [mm] 2 x (15 x 3) 2 x (15 x 3) 2 x (20 x 3) 2 x (30 x 5) 2 x (30 x 5) - - -
Tightening Torquelb-in
(Nm)
47.8-53.1
(5.4-6)
47.8-53.1
(5.4-6)
123.9-141.6
(14-16)
203.6-230.1
(23-26)
203.6-230.1
(23-26)
203.6
(23)
504.5
(57)
504.5
(57)
Operating Position see below
Operating Position
CWM9 to CWM105 CWM112 to CWM800
102
Industrial Control Products4.20
www.pamensky.com
Power Contacts - CWM9 to CWM105
Type CWM9 CWM12 CWM18 CWM25 CWM32 CWM40 CWM50 CWM65 CWM80 CWM95 CWM105
Standard UL/CSA Ratings
Rated Operating Voltage [V] 600
General Purpose Rating [A] 25 25 32 32 60 60 90 110 110 140 140
Switching Motor Loads
Full Voltage - 60Hz
1-phase 115V [A] 9.8 13.8 16 24 34 34 56 56 80 80 100
230V [A] 10 12 17 28 28 28 40 50 68 68 88
115V [HP] 1/2 3/4 1 2 3 3 5 5 7-1/2 7-1/2 10
230V [HP] 1-1/2 2 3 5 5 5 7-1/2 10 15 15 20
3-phase 200V [A] 11 11 17.5 25 32.2 32.2 48.3 62.1 62.1 78.2 92
230V [A] 9.6 9.6 15.2 22 28 42 42 54 68 80 104
460V [A] 7.6 11 14 21 27 40 52 65 65 77 96
575V [A] 9 11 17 17 27 27 41 52 62 77 77
200V [HP] 3 3 5 7-1/2 10 10 15 20 20 25 30
230V [HP] 3 3 5 7-1/2 10 15 15 20 25 30 40
460V [HP] 5 7-1/2 10 15 20 30 40 50 50 60 75
575V [HP] 7-1/2 10 15 15 25 25 40 50 60 75 75
Standard IEC Ratings
Rated Operating Voltage [V] 690 1000
Rated Thermal Current Ith [A] 25 25 32 45 60 60 90 110 110 140 140
Switching Motor Loads
AC-2; AC-3; AC-4 - 50Hz
3-phase 220-240V [A] 9 12 18 25 32 40 50 65 80 95 105
380-400V [A] 9 12 18 25 32 40 50 65 80 95 105
415-440V [A] 9 12 18 25 32 40 50 65 80 95 105
500V [A] 7.5 10.5 14 19 24 32 38 55 63 79 85
660-690V [A] 7 9 13 15 22 25 34 44 48 60 80
220-240V [kW] 2.2 3 4 7.5 9 11 15 18.5 22 25 30
380-400V [kW] 4 5.5 7.5 11 15 18.5 22 30 37 45 55
415-440V [kW] 4 5.5 7.5 11 15 22 25 37 45 50 55
500V [kW] 5.5 7.5 10 15 18.5 25 30 40 45 55 65
660-690V [kW] 5.5 7.5 10 15 18.5 30 35 45 45 55 65
Maximum Switching Rate
AC-4
AC-1 [ops/hr] 1,200 1,200 1,200 1,200 1,200 1,200 1,200 1,200 1,200 1,200 1,200
AC-3 [ops/hr] 1,200 1,200 1,200 1,200 1,200 1,200 1,200 1,200 1,200 600 600
no load [ops/hr] 9,000 9,000 9,000 9,000 9,000 9,000 5,000 5,000 5,000 5,000 5,000
200,000 operations <= 690V [A] 5 7 8 12 16 18.5 23 30 37 44 50
50/60Hz 220-230V [kW] 1.1 1.5 1.5 3 4 4.5 5.5 7.5 9.2 11 12.5
[HP] 1.5 2 2 4 5.4 6 7.5 10 12.5 15 17
380-400V [kW] 2.2 3 3.7 5.5 7.5 9.2 11 15 18.5 22 22
[HP] 3 4 5 7.5 10 12.5 15 20 25 30 30
415-440V [kW] 2.2 3.7 4.5 5.5 9.2 11 11 15 22 22 30
[HP] 3 5 6 7.5 12.5 15 15 20 30 30 40
500V [kW] 3 4 5.5 7.5 10 11 15 18.5 22 25 30
[HP] 4 5.4 7.5 10 13 15 20 25 30 33 40
660-690V [kW] 3 4.5 5.5 7.5 11 12.5 15 20 25 30 33
[HP] 4 6 7.5 10 15 17 20 27 33 40 45
Maximum Switching Rate [ops/hr] 360 360 360 360 360 200 200 200 200 200 200
Making Capacity [A] 450 450 450 450 550 1000 1000 1000 1000 1280 1280
Breaking Capacity Ue=400V
Ue<=400V[A] 250 250 250 450 450 920 920 920 920 1050 1050
Ue=500V [A] 250 250 250 320 450 920 920 920 920 1050 1050
Ue=690V [A] 130 130 130 170 205 780 780 780 780 950 950
Impedance per Pole [mW] 2.41 2.41 2.35 1.65 1.28 0.95 0.85 0.86 0.86 0.76 0.76
Power Dissipation per Pole
AC-1 [W] 1.47 1.47 2.46 3.34 4.6 3.42 6.86 10.4 10.4 14.89 14.89
AC-3 [W] 0.19 0.34 0.78 1.03 1.31 1.52 2.12 3.63 5.5 6.86 8.37
Short Time Current Icw
1 sec. [A] 455 455 570 630 1010 1265 1580 2530 2530 3300 3300
5 sec. [A] 205 205 254 280 450 450 710 1130 1130 1485 1485
10 sec. [A] 144 144 180 200 320 400 500 800 800 1050 1050
30 sec. [A] 85 85 104 115 185 230 290 460 460 600 600
1 min. [A] 60 60 74 80 130 165 205 325 325 430 430
3 min. [A] 35 35 46 50 90 100 120 185 185 250 250
Rec. time [min.] 10 10 10 10 10 10 10 10 10 10 10
Short Circuit Coordination
Coordination Type “1” gL/gG [A] 50 50 63 63 100 125 200 200 200 250 250
Coordination Type “2” gL/gG [A] 25 35 35 50 63 80 100 125 125 160 200
CWM Standard Contactors - Technical Data
102
Industrial Control Products 4.21
www.pamensky.com
CWM Standard Contactors - Technical DataPower Contact - CWM112 to CWME800
Type CWM112 CWM150 CWM180 CWM250 CWM300 CWME400 CWME630 CWME800
UL/CSA Applications
Rated Operating Voltage [V] 600
General Purpose Rating [A] 170 170 200 300 400 450 660 900
Switching Motor Loads
Full Voltage - 60Hz
1-phase 115V [A] - - - - - - - -
230V [A] - - - - - - - -
115V [HP] - - - - - - - -
230V [HP] - - - - - - - -
3-phase 200V [A] 120 150 177 221 285 359 414 552
230V [A] 130 154 192 248 312 360 480 772
460V [A] 124 156 180 240 302 361 477 -
575V [A] 99 144 192 242 336 289 382 -
200V [HP] 40 50 60 75 100 125 150 200
230V [HP] 50 60 75 100 125 150 200 300
460V [HP] 100 125 150 200 250 300 400 600
575V [HP] 100 150 200 250 350 300 400 600
Standard IEC Ratings
Rated Operating Voltage [V] 1000
Rated Thermal Current Ith [A] 180 225 225 350 350 450 660 900
Switching Motor Loads
AC-3 - 60Hz
3-phase 220-240V [A] 112 150 180 250 300 400 630 800
380-400V [A] 112 150 180 250 300 400 630 800
415-440V [A] 112 150 180 250 300 400 630 800
500V [A] 95 130 155 220 265 350 500 720
660-690V [A] 82 110 135 185 220 300 420 630
220-240V [kW] 30 45 55 75 90 110 185 220
380-400V [kW] 55 75 90 132 160 220 330 450
415-440V [kW] 55 90 110 150 185 220 370 500
500V [kW] 55 90 110 160 200 220 330 500
660-690V [kW] 75 110 110 160 200 260 400 560
Maximum Switching
Rate AC-1 [ops/hr] 600 600 600 600 600 500 500 500
AC-3 [ops/hr] 600 600 600 600 600 500 500 500
no load [ops/hr] 1,000 1,000 1,000 1,000 1,000 1,000 1,000 1,000
AC-4
200,000 operations <= 690V [A] 50 55 58 100 130 - - -
50/60Hz220-230V
[kW] 18.5 20 22 37 45 90 110 185
[HP] 25 27 30 50 60 125 150 250
380-400V[kW] 30 33 37 55 75 150 220 330
[HP] 40 44 50 75 100 200 300 450
415-440V[kW] 37 40 45 63 80 185 220 370
[HP] 50 54 60 84 107 250 300 500
500V[kW] 40 45 50 75 90 - - -
[HP] 54 60 67 100 121 - - -
660-690V[kW] 45 50 55 90 100 - - -
[HP] 600 67 75 121 133 - - -
Maximum Switching
Rate[ops/hr] 150 150 150 150 150 - - -
Making Capacity [A] 1430 1820 2100 2600 3000
Breaking Capacity
Ue<=400V [A] 1290 1350 1400 2000 - 4000 6300 8000
Ue=500V [A] 1290 1350 1400 2000 - 4000 6300 8000
Impedance per pole [mW] 0.5 0.5 0.45 0.3 0.3 - - -
Power Dissipation per Pole
AC-1 [W] 16 25 21.6 35 45.7 - - -
AC-3 [W] 6.2 11.1 13.8 17.9 25.7 - - -
Short Time Current Icw
1 sec. [A] 3165 3763 4649 4427 - - - -
5 sec. [A] 1820 2164 2673 2546 - - - -
10 sec. [A] 1430 1700 2100 2000 - - - -
30 sec. [A] 826 980 1212 1155 - - - -
1 min. [A] 584 694 857 816 - - - -
3 min. [A] 337 401 495 471 - - - -
Recovery time [min.] 10 10 10 10 10 - - -
Short Circuit Coordination
Coordination type “1” gL/gG [A] 315 355 355 500 630 630 800 1000
Coordination type “2” gL/gG [A] 224 250 250 400 500 - - -
102
Industrial Control Products4.22
www.pamensky.com
Built-in Auxiliary Contacts - CWM9 to CWM18
Type CWM9 CWM12 CWM18
Rated Insulation Voltage Ui
Acc. IEC; VDE 0660 [V] 1000
Acc. UL; CSA [V] 600
Rated Operating Voltage Ue
Acc. IEC; VDE 0660 [V] 690
Acc. UL; CSA [V] 600
Rated Thermal Current Ith <=55oC [A] 20
Rated Operating Current Ie
Acc. IEC 60947-5-1 / AC-15
110-127V [A] 10
220-240V [A] 10
380-400V [A] 6
415-450V [A] 5
500V [A] 4
660-690V [A] 2
Acc. UL; CSA A600
Rated Operating Current Ie
Acc. IEC 60947-5-1 / DC-13
24V [A] 6
48V [A] 4
110V [A] 2
220V [A] 0.7
440V [A] 0.7
Acc. UL; CSA P600
Making Capacity Im
AC-15 / AC-11 Ue <= 690V 50/60Hz [A] 250
DC-13 / DC-11 Ue <= 440Vdc [A] 250
Breaking Capacity Ic
AC-15 / AC-11 Ue <= 400V 50/60Hz [A] 250
DC-13 / DC-11 Ue <=220Vdc [A] 2
Short Circuit Protection with Fuses
Acc. IEC 60947-5-1 - gL/gG [A] 10
Minimum Switching Capacity [V/mA] 17/5
Electrical Endurance Million ops. 1
Mechanical Endurance Million ops. 10
Guaranteed Non-Overlap Time [ms] 1.5
Insulation Resistance [MOhm] >10
CWM Standard Contactors - Technical Data
Control Circuit Ratings - AC Coil - CWM9 to CWM105
Type CWM9 CWM12 CWM18 CWM25 CWM32 CWM40 CWM50 CWM65 CWM80 CWM95 CWM105
Rated Insulation Voltage Ui
Acc. IEC; VDE 0660 [V] 1000
Acc. UL; CSA [V] 600
Rated Operating Voltage Ue
Acc. IEC; VDE 0660 [V] 690
Acc. UL; CSA [V] 600
Standard Voltages 60Hz [V] 24...600
Coil Operating limits
Monofrequency coils xUc 0.85…1.1
Pick-up xUc [V] 0.4...0.76 0.5...0.76 0.5...0.76
Drop-out xUc [V] 0.25...0.65 0.3...0.65 0.25...0.6
Reinforced coils xUc
Pick-up xUc [V] 0.4...0.7
Drop-out xUc [V] 0.3...0.6
Operating Time
Coil energization - N.O. [ms] 8...20 10...19 15...30
Coil de-energization - N.O. [ms] 6...13 5...25 9...15
Coil Consumption
Monofrequency coils
Sealed [VA] 5.5...9.3 9.5...12.5 16.8...25 16.8...25
Inrush [VA] 70 115 295 295
Thermal Power Dissipation
60Hz [W] 2.6 4.3 8.0
Power Factor
Closed Cos phi 0.28 0.34 0.32
Opened Cos phi 0.85 0.69 0.54
102
Industrial Control Products 4.23
www.pamensky.com
CWM Standard Contactors - Technical DataControl Circuit Ratings - DC Coil - CWM9 to CWM105
Type CWM9 CWM12 CWM18 CWM25 CWM32 CWM40 CWM50 CWM65 CWM80 CWM95 CWM105
Rated Insulation Voltage Ui
Acc. IEC; VDE 0660 [V] 1000
Acc. UL; CSA [V] 600
Standard Voltages [V] 12...440 24...240 24...240
Coil Operating limits 0.85...1.1
Pick-up xUc [V] 0.4...0.7 0.45...0.75 0.7...0.8
Drop-out xUc [V] 0.15...0.4 0.15...0.45 0.4...0.6
Operating Time
Coil energization - N.O. [ms] 35...45 40...55 50...60
Coil de-energization - N.O. [ms] 7...12 30...65 55...60
Coil Consumption
Closed [W] 3.8...7.5 6 6.5
Magnetic circuit opened [W] 3.8...7.5 240 340
Electronic Module Control Circuit - CWM112 to CWME800
Type CWM112 CWM150 CWM180 CWM250 CWM300 CWME400 CWME630 CWME800
Rated Insulation Voltage Ui
Acc. IEC; VDE 0660 [V] 1000
Acc. UL; CSA [V] 600
Rated Operating Voltage Ue
Acc. IEC; VDE 0660 [V] 690
Acc. UL; CSA [V] 600
Standard Voltages 50Hz; 60Hz; DC [V] 24…600
Coil Operating limits
xUc [V] 0.65…1.1
Pick-up xUc [V] 0.70...0.85
Drop-out xUc [V] 0.40...0.60
Operating Time
Coil energization - N.O. [ms] 60…70 60…70 60…70 60…70 60…70 64…68 66…70 66…70
Coil de-energization - N.O. [ms] 13…17 13…17 13…17 13…17 13…17 43…47 45…49 45…49
Coil Consumption
Closed AC [VA] 14.8 14.8 14.1 14.1 14.1 14 17 29
Opened AC [VA] 213 213 214 229 229 571 1000 1000
Closed DC [VA] 2.4 2.4 2.4 2.5 2.5 14 17 17
Opened DC [VA] 166 166 154 171 171 571 1000 1000
Thermal Power Dissipation
AC [W] 3.9 3.9 3.8 3.7 3.7 4.7 4.9 5.3
DC [W] 2.4 2.4 2.4 2.5 2.5 5.0 6.3 7.8
102
Industrial Control Products4.24
www.pamensky.com
Auxiliary Contact Block Ratings
Type BCXMF BCXML BCXMRL BLIM.02
Rated Insulation Voltage Ui
Acc. IEC; VDE 0660 [V] 1000
Acc. UL; CSA [V] 600
Rated Operating Voltage Ue
Acc. IEC; VDE 0660 [V] 690
Acc. UL; CSA [V] 600
Rated Thermal Current Ith <=55oC [A] 10
Rated Operating Current Ie
Acc. IEC 60947-5-1 / AC-15 110-127V [A] 6
220-240V [A] 6
380-400V [A] 4
415-450V [A] 3.5
500V [A] 2.5
660-690V [A] 1.5
Acc. UL; CSA A600
Rated Operating Current Ie
Acc. IEC 60947-5-1 / DC-13 24V [A] 4
48V [A] 2
110V [A] 0.7
220V [A] 0.3
440V [A] 0.15
Acc. UL; CSA Q600
Making Capacity Im
AC-15 / AC-11 Ue <= 400V 50/60Hz [A] 90
DC-13 / DC-11 Ue <= 220Vdc [A] 90
Breaking Capacity Ic
AC-15 / AC-11 Ue <= 400V 50/60Hz [A] 60
DC-13 / DC-11 Ue <= 220Vdc [A] 0.95
Short Circuit Protection with Fuses
Acc. IEC 60947-5-1 - gL/gG [A] 10
Minimum Switching Capacity [V/mA] 17/5
Electrical Endurance Million ops. 1
Mechanical Endurance Million ops. 10
Guaranteed Non-Overlap Time [ms] 1.5
Insulation Resistance [MOhm] >10
CWM Standard Contactors - Technical Data
102
Industrial Control Products 4.25
www.pamensky.com
RW Thermal Overload RelaysRW overload relays are important equipment within the WEG Controls range of products. As
usual for WEG products, an extended operational service life is one of the main features you
will fi nd in RW overload relays. WEG’s RW Class 10 Thermal Overload Relays are designed
to work with, and compliment WEG’s minicontactors and contactors. Effectively, RW overload
relays can be mounted directly to WEG minicontactors and contactors, assuring electrical and
mechanical operation as an open across-the-line starter.
Features
Dial FLC SettingThe trip-current is set via an infi nitely adjustable dial designed for the motor’s full load current.
Temperature CompensationBecause RW overload relays include a fourth bimetallic strip in addition to the three that are
directly heated by the motor current, ambient temperature variations in the range of -20ºC
to +60ºC are no obstacle for accurate protection of your motors under even the toughest
conditions.
Phase Failure SensitivityWEG overload relays include phase failure sensitivity protection as standard. This feature
ensures fast tripping in case of phase loss, protecting your motor and avoiding expensive
repairs or corrective maintenance services.
Multi Function ButtonThe programmable RESET button can be selected to operate in a Manual or Automatic mode,
with or without TEST capabilities of the isolated “trip” NC and “alarm” NO auxiliary contacts.
The multifunction RESET / TEST button can be set in four different positions; H (manual
RESET only), HAND (manual RESET/TEST), AUTO (automatic RESET/ TEST) and A (automatic
RESET only). In HAND and AUTO positions, when RESET button is pushed, both NO (97-98)
and NC (95-96) contacts change states.
102
Industrial Control Products4.26
www.pamensky.com
RW - Part Number Specifi cation-
2
27-1D
4
D004
3
3
1
RW
1. RW Thermal Overload Relay
2. Frame Size and Terminal Type:
17-1D: to use with CWC07…016
17-2D: to use with CWC025
27-1D: to use with CWM9…25
67-1D: to use with CWM32…40
67-2D: to use with CWM50…80
117-1D: to use with CWM95…105
117-2D: to use with CWM112…150
317-1D: to use with CWM112…300
407-1D: to use with CWME400…800
3. Power Pole: 3: 3 NO Power Poles
2: 2 NO Power Poles
4. Overload Setting Current:
RW17 RW27 RW67 RW117 RW317 RW407
Description Code Description Code Description Code Description Code Description Code Description Code
0.28 ... 0.40A D004 0.28 ... 0.40A D004 25 ... 40A U040 63 … 80A U080 100 … 150A U150 400 … 600A U600
11 … 32A U032 11 … 32A U032 63 … 80A U080 90 ... 112A U112 275 ... 420A U420 560 ... 840A U840
102
Industrial Control Products 4.27
www.pamensky.com
Three Pole Contactors with AC Coil
Electrical Data Purchasing Data
For Contactor
Setting Range (A)
Max. Fuse
(A)Part Number List Price
Min. Max.
CWC07…CWC016 & CWCA0 (Mini-Contactor) 0.28 0.40 15 RW17-1D3-D004 $44
CWC07…CWC016 & CWCA0 (Mini-Contactor) 0.40 0.63 15 RW17-1D3-C063 44
CWC07…CWC016 & CWCA0 (Mini-Contactor) 0.56 0.80 15 RW17-1D3-D008 44
CWC07…CWC016 & CWCA0 (Mini-Contactor) 0.80 1.20 15 RW17-1D3-D012 44
CWC07…CWC016 & CWCA0 (Mini-Contactor) 1.20 1.80 15 RW17-1D3-D018 44
CWC07…CWC016 & CWCA0 (Mini-Contactor) 1.80 2.80 15 RW17-1D3-D028 44
CWC07…CWC016 & CWCA0 (Mini-Contactor) 2.80 4.00 15 RW17-1D3-U004 44
CWC07…CWC016 & CWCA0 (Mini-Contactor) 4.00 6.30 25 RW17-1D3-D063 44
CWC07…CWC016 & CWCA0 (Mini-Contactor) 5.60 8.00 30 RW17-1D3-U008 44
CWC07…CWC016 & CWCA0 (Mini-Contactor) 7.00 10.0 40 RW17-1D3-U010 44
CWC07…CWC016 & CWCA0 (Mini-Contactor) 8.00 12.5 50 RW17-1D3-D125 44
CWC07…CWC016 & CWCA0 (Mini-Contactor) 10.0 15.0 60 RW17-1D3-U015 44
CWC07…CWC016 & CWCA0 (Mini-Contactor) 11.0 17.0 60 RW17-1D3-U017 44
CWC025 (Mini-Contactor) 15.0 23.0 90 RW17-2D3-U023 45
CWC025 (Mini-Contactor) 22.0 32.0 100 RW17-2D3-U032 45
CWM9...CWM40 0.28 0.40 15 RW27-1D3-D004 48
CWM9...CWM40 0.40 0.63 15 RW27-1D3-C063 48
CWM9...CWM40 0.56 0.80 15 RW27-1D3-D008 48
CWM9...CWM40 0.80 1.20 15 RW27-1D3-D012 48
CWM9...CWM40 1.20 1.80 15 RW27-1D3-D018 48
CWM9...CWM40 1.80 2.80 15 RW27-1D3-D028 48
CWM9...CWM40 2.80 4.00 15 RW27-1D3-U004 48
CWM9...CWM40 4.00 6.30 25 RW27-1D3-D063 48
CWM9...CWM40 5.60 8.00 30 RW27-1D3-U008 54
CWM9...CWM40 7.00 10.0 40 RW27-1D3-U010 54
CWM9...CWM40 8.00 12.5 50 RW27-1D3-D125 54
CWM9...CWM40 10.0 15.0 60 RW27-1D3-U015 54
CWM9...CWM40 11.0 17.0 60 RW27-1D3-U017 54
CWM9...CWM40 15.0 23.0 90 RW27-1D3-U023 54
CWM9...CWM40 22.0 32.0 90 RW27-1D3-U032 54
CWM32...CWM40 25.0 40.0 90 RW67-1D3-U040 92
CWM32...CWM40 32.0 50.0 125 RW67-1D3-U050 100
CWM50...CWM80 25.0 40.0 90 RW67-2D3-U040 100
CWM50...CWM80 32.0 50.0 125 RW67-2D3-U050 100
CWM50...CWM80 40.0 57.0 150 RW67-2D3-U057 100
CWM50...CWM80 50.0 63.0 150 RW67-2D3-U063 152
CWM50...CWM80 57.0 70.0 175 RW67-2D3-U070 152
CWM50...CWM80 63.0 80.0 175 RW67-2D3-U080 152
CWM95...CWM105 63.0 80.0 200 RW117-1D3-U080 152
CWM95...CWM105 75.0 97.0 225 RW117-1D3-U097 152
CWM95...CWM105 90.0 112 250 RW117-1D3-U112 152
CWM112E...CWM150E 75.0 97 225 RW117-2D3-U097 154
CWM112E...CWM150E 90.0 112 250 RW117-2D3-U112 154
CWM112E…CWM300E 100 150 300 RW317-1D3-U150 215
CWM112E…CWM300E 140 215 350 RW317-1D3-U215 215
CWM112E…CWM300E 200 310 500 RW317-1D3-U310 269
CWME400...CWME800 275 420 700 RW317-1D3-U420 269
CWME400...CWME800 400 600 1000 RW407-1D3-U600 632
CWME400...CWME800 560 840 1250 RW407-1D3-U840 692
RW Thermal Overload Relays - Accessories
RW Thermal Overload Relays - Table of Products
Mounting Brackets
Description Part Number List Price
Enables overload to be mounted directly to a panel via screws or DIN rail RW27-1D BF27D $14
Enables overload to be mounted directly to a panel via screws or DIN rail RW67-1D BF67.1D 24
Enables overload to be mounted directly to a panel via screws or DIN rail RW67-2D BF67.2D 24
Enables overload to be mounted directly to a panel via screws or DIN rail RW117-1D BF117D 30
102
Industrial Control Products4.28
www.pamensky.com
RW Thermal Overload Relays - Technical Data
General Ratings
Type RW17D RW27D RW67D RW117D RW317D
Standards Devices according to International Standards, IEC 60947-4-1 and Underwriters Laboratories, UL
Number of poles 3
Tripping Class 10
Phase failure sensitivity Yes
Temperature Compensation Yes
Multi function button R Yes
Rated Insulation Voltage Ui
acc. IEC 60947-4-1 [V] 690 1000
acc. UL; CSA [V] 600
Rated Operation Voltage Ue
acc. IEC 60947-4-1 [V] 690 1000
acc. UL; CSA [V] 600
Rated Impulse Voltage
UimpkV 6
Current
direct yes no
alternating Hz up to 400 Hz 50/60 Hz
Degree of protection Protection against direct contact acc. VDE 0160 - Part 100 - IP20
Temperature Compensation -20 to +60oC (-4 to 140oF)
Storage -50 to +80oC (-58 to 176oF)
Operating -20 to +70oC (-4 to 158oF)
Pollution Degree 3
Mounting Direct on contactor or separately with the accessory
Power Dissipation per pole W up to 3 up to 5.5 -
WeightKgs. 0.15 0.147 0.31 0.52 2.3
Lbs. 0.33 0.323 0.683 1.15 5.06
Dimensions
height mm 45 79.5 73 100 155
width mm 79.5 45 50 75 115
lenght mm 92 92 106 99 166
Shock Resistance
IEC 60 068 part 2-27 g/ms 8/10
Front auxiliary contact 1 NO + 1 NC
Rated auxiliary contacts
24V A 4
60V A 3.5
125V A 3
AC (AC-14/15), 230V A 2
400V A 1.5
500V A 0.5
690V A 0.3
DC (DC-13/14), 24V A 1
60V A 0.5
110V A 0.25
220V A 0.1
Rated thermal current A 6
Short Circuit protection
Fuses type D or NH gL/gG 6
Terminal Capacity
Type RW17D RW27D RW67D RW117D RW317D
Terminal Description Cross / Slotted Combination Allen Head Slide bar
Fine - Stranded with Sleeve (mm2) 1.5 - 10 1.5 - 10 6.0 - 35 6.0 - 35 -
Coarse - Stranded / Solid (mm2) 1.5 - 6.0 1.5 - 6.0 6.0 - 35 25 - 35 -
Slide Bars max. (mm2) - - - - 2x(25x5)
Tightening Torque Nm 1.4 - 2.3 1.4 - 2.3 4.0 - 6.0 4.0 - 6.0 14 - 26
Stranded / Solid (UL / CSA) AWG - min and max. 14 - 6 14 - 6 18 - 2 8 – 1/0 8 – 1/0
Tightening Torque Lb-in 20 20 20 40 40
102
Industrial Control Products 4.29
www.pamensky.com
Operating Positions
RW17D, RW27D, RW67D, RW117D, RW317D, RW407D
RW27D, RW67D, RW117D, RW317D, RW407D
RW17D with CWC07
Mounting without contactor
The relays can be mounted at any position.
Mounting without contactor
The mounting position showed in the left-hand figure is equivalent to 0° - not requiring a correction factor on the dial of the relay. The assembly can work with mounting variations of 0° to 180°. However, the mounting with the relay above the contactor, position between 135° and 225°, requires a correction factor of +10% on the dial of the relay. Laterally, as shown in the right-hand figure, the inclination can not exceed ±30° for perfect functioning of the contactor.
As shown in the left-hand figure, the inclination can not exceed ±30° for perfect functioning of the contactor. Laterally, as shown in the right-hand figure, the mounting position is equivalent to 0° - not requiring a correction factor on the dial of the relay. The assembly can work with mounting variations of 0° to 180°.
RW Thermal Overload Relays - Technical Data
102
Industrial Control Products4.30
www.pamensky.com
WEG Manual Motor Protectors are the state-of-the-art products available for the worldwide
market. With the latest technology and design, you’ll fi nd how easy is to save panel space
and to face almost any application in motor control. Built in a very compact frame size, WEG’s
Manual Motor Protectors combine, motor control, disconnect means short-circuit and motor
overload protections in just one component.
These devices include pushbutton operators or a three-position rotary ON-TRIP-OFF handle,
which can be padlocked in the OFF position. WEG Manual Motor Protectors are designed for
DIN rail mounting, while lugs for direct panel mounting are also available as an accessory.
Features
• High short-circuit interrupting rating – up to
50kA @ 480V
• Current limiting short-circuit protection
• Thermal overload protection Class 10
• Phase loss sensitivity protection
• Ambient temperature compensation -4ºF
+140ºF (-20ºC +60ºC)
• Lockable rotary handle mechanism for
disconnect
• Visual indication of ON-TRIP-OFF status
• 35mm DIN-rail mounting
• Snap-in accessories
• Finger safe protected terminals
• Rated for DC applications
• Test trip feature
• Coordination type 2 per IEC60947-4-1 and
UL508E, with WEG’s CWM contactors
• Manual Motor Starters
• Group motor installations (per NEC Article
430)
• Multi-motor starter applications
• Suitable for motor disconnect applications
• UL Type-E self protected combination starter
MPW Manual Motor Protector
102
Industrial Control Products 4.31
www.pamensky.com
MPW - Part Number Specifi cation- -
2 3
25 3
4
U016
1
MPW
1. MPW Manual Motor Protector
2. Frame Size: 25: to use with CWC07…025 & CWM9…40
65: to use with CWM32…80
100: to use with CWM95…105
3. Power Pole: 3: 3 NO Power Poles
4. Overload Setting Current:
MPW25 MPW65 MPW100
Description Code Description Code Description Code
0.10 ... 0.16A C016 10 … 16A U016 55 … 75A U075
25 … 32A U032 50 ... 65A U065 80 ... 100A U100
102
Industrial Control Products4.32
www.pamensky.com
MPW Manual Motor Protector - Table of ProductsManual Motor Protector MPW25
Electrical Data Purchasing Data
Maximum UL Horsepower Thermal
Setting
Short-Circuit
interruption capacity Part NumberList
PriceSingle Phase Three Phase
115V 230V 200V 230V 460V 575V [A] 480V 600V
- 1/10 1/4 1/3 3/4 1 1.0 - 1.6 50kA 25kA MPW25-3-D016 $100
- 1/6 1/2 1/2 1 1/2 1 1/2 1.6 - 2.5 50kA 25kA MPW25-3-D025 100
1/8 1/3 3/4 1 2 3 2.5 - 4.0 50kA 25kA MPW25-3-U004 100
1/4 3/4 1 1/2 1 1/2 3 5 4.0 - 6.3 50kA 25kA MPW25-3-D063 100
1/2 1 1/2 3 3 5 7 1/2 6.3 - 10 50kA 25kA MPW25-3-U010 110
1 3 5 5 10 15 10 - 16 50kA 25kA MPW25-3-U016 110
1 1/2 3 5 7 1/2 15 15 16 - 20 50kA 25kA MPW25-3-U020 124
2 3 7 1/2 7 1/2 15 20 20 - 25 50kA 25kA MPW25-3-U025 146
- 5 10 10 20 25 25 - 32 42kA 25kA MPW25-3-U032 158
Manual Motor Protector MPW65
Electrical Data Purchasing Data
Maximum UL Horsepower Thermal
Setting
Short-Circuit
interruption capacity Part NumberList
PriceSingle Phase Three Phase
115V 230V 200V 230V 460V 575V [A] 480V 600V
3 7 1/2 - 15 25 30 32 ... 40 35kA 10kA MPW65-3-U040 $300
- 10 15 15 30 40 40 ... 50 35kA 10kA MPW65-3-U050 300
5 10 20 20 50 60 50 ... 65 35kA 10kA MPW65-3-U065 300
Manual Motor Protector MPW100
Electrical Data Purchasing Data
Maximum UL Horsepower Thermal
Setting
Short-Circuit
interruption capacity Part NumberList
PriceSingle Phase Three Phase
115V 230V 200V 230V 460V 575V [A] 480V 600V
5 15 20 25 50 60 55 ... 75 50kA 10kA MPW100-3-U075 $500
7 1/2 20 25 30 60 75 70 ... 90 50kA 10kA MPW100-3-U090 534
10 20 30 30 75 100 80 ... 100 50kA 10kA MPW100-3-U100 534
102
Industrial Control Products 4.33
www.pamensky.com
MPW Manual Motor Protector - AccessoriesAuxiliary Contact Blocks
Description For Protector Part Number List Price
1NO&1NC auxiliary contact block front mounting - 250Vmax. MPW25 & MPW65 ACBF-11 $14
1NO&1NC auxiliary contact block left side mounting - 600Vmax. MPW25 & MPW65 ACBS-11 14
2NO Auxiliary contact block left side mounting - 600Vmax. MPW25 & MPW65 ACBS-20 14
2NC Auxiliary contact block left side mounting - 600Vmax. MPW25 & MPW65 ACBS-02 14
1NO&1NC auxiliary contact block front mounting - 250Vmax. MPW100 ACBF-11 MPW100 28
1NO&1NC auxiliary contact block left side mounting - 600Vmax. MPW100 ACBS-11 MPW100 40
2NO Auxiliary contact block left side mounting - 600Vmax. MPW100 ACBS-20 MPW100 40
2NC Auxiliary contact block left side mounting - 600Vmax. MPW100 ACBS-02 MPW100 40
Accessories for Group Motor Installation
Description For Protector Part Number List Price
Income power terminal for bus bar system MPW25 FTBBS $23
Bus bar system 45mm (for 2 MPW without side mounting auxiliary contacts) MPW25 BBS45-2 24
Bus bar system 45mm (for 3 MPW without side mounting auxiliary contacts) MPW25 BBS45-3 28
Bus bar system 45mm (for 4 MPW without side mounting auxiliary contacts) MPW25 BBS45-4 36
Bus bar system 45mm (for 5 MPW without side mounting auxiliary contacts) MPW25 BBS45-5 38
Bus bar system 54mm (for 2 MPW with side mounting auxiliary contacts) MPW25 BBS54-2 28
Bus bar system 54mm (for 3 MPW with side mounting auxiliary contacts) MPW25 BBS54-3 32
Bus bar system 54mm (for 4 MPW with side mounting auxiliary contacts) MPW25 BBS54-4 38
Bus bar system 54mm (for 5 MPW with side mounting auxiliary contacts) MPW25 BBS54-5 39
Link Modules
Description For Protector Part Number List Price
Mechanical and electrical link module for CWC07 to CWC016 miniature contactor
seriesMPW25 ECCMP-07 $11
Mechanical and electrical link module for CWM9…CWM25 contactor series MPW25 ECCMP-25 11
Accessories for Combination Type-E Construction
Description For Protector Part Number List Price
Line power terminal MPW25 LST25 $31
Trip Signaling and Alarm Contact Block (1NO&1NC for Short-circuit and 1NO&1NC for
Overload) MPW25 & MPW65 TSB-22 33
Line power terminal MPW65 LST65 68
Insulators MPW100 IB MPW100 15
Trip Signaling and Alarm Contact Block (1NO&1NC for Short-circuit and Overload) MPW100 TSB-11 MPW100 40
102
Industrial Control Products4.34
www.pamensky.com
Through-the-door Rotary Mechanisms NEMA 1
Description For Protector Part Number List Price
Rotary NEMA 1 Through the Door Mechanism - gray/black handle with 130mm shaft MPW25 RMMP-130 $58
Rotary NEMA 1 Through the Door Mechanism - yellow/red handle with 130mm shaft MPW25 RMMP-130-E 58
Rotary NEMA 1 Through the Door Mechanism - gray/black handle with 330mm shaft MPW25 RMMP-330 69
Rotary NEMA 1 Through the Door Mechanism - yellow/red handle with 330mm shaft MPW25 RMMP-330-E 69
Rotary NEMA 1 Through the Door Mechanism - gray/black handle with 130mm shaft MPW65 RMMP65-130 58
Rotary NEMA 1 Through the Door Mechanism - yellow/red handle with 130mm shaft MPW65 RMMP65-130-E 58
Rotary NEMA 1 Through the Door Mechanism - gray/black handle with 330mm shaft MPW65 RMMP65-330 69
Rotary NEMA 1 Through the Door Mechanism - yellow/red handle with 330mm shaft MPW65 RMMP65-330-E 69
Rotary NEMA 1 Through the Door Mechanism - gray/black handle with 115 mm shaft MPW100 MR MPW100-115 80
Rotary NEMA 1 Through the Door Mechanism - gray/black handle with 315mm shaft MPW100 MR MPW100-315 80
Through-the-door Rotary Mechanisms NEMA 4X
Description For Protector Part Number List Price
Rotary NEMA 4X Through the Door Mechanism - gray/black handle with 130mm shaft MPW25 MRX-130 62
Rotary NEMA 4X Through the Door Mechanism - yellow/red handle with 130mm shaft MPW25 MRX-130-E 62
Rotary NEMA 4X Through the Door Mechanism - gray/black handle with 330mm shaft MPW25 MRX-330 72
Rotary NEMA 4X Through the Door Mechanism - yellow/red handle with 330mm shaft MPW25 MRX-330-E 72
Rotary NEMA 4X Through the Door Mechanism - black/red handle with 130mm shaft MPW65 MRX65-130 63
Rotary NEMA 4X Through the Door Mechanism - yellow/red handle with 130mm shaft MPW65 MRX65-130-E 63
Rotary NEMA 4X Through the Door Mechanism - black/red handle with 330mm shaft MPW65 MRX65-330 72
Rotary NEMA 4X Through the Door Mechanism - yellow/red handle with 330mm shaft MPW65 MRX65-330-E 72
Rotary NEMA 4X Through the Door Mechanism - gray/black handle with 130mm shaft MPW100 MRX100-130 86
Rotary NEMA 4X Through the Door Mechanism - yellow/red handle with 130mm shaft MPW100 MRX100-130E 86
MPW Manual Motor Protector - Accessories
102
Industrial Control Products 4.35
www.pamensky.com
MPW Manual Motor Protector - Technical DataGeneral Ratings
Part Number MPW25 MPW65 MPW100
Maximum Rated Current Imax
(Iu) 32A 65A 100A
Number of poles 3 3 3
Instantaneous short-circuit 13 x Iemax. 13 x I
emax. 13 x I
emax.
Rated operational voltage Ue
690V 1) 690V 690V
Rated operational frequency 2) 50/60Hz 50/60Hz 50/60Hz
Insulation Voltage Ui
690V 690V 1000V
Rated impulse withstand voltage Uimp
6kV 6kV 8kV
Utilization category IEC 60 947-2 (Circuit breaker) A A A
IEC 60 947-4-1 (Motor starter) AC-3 AC-3 AC-3
Tripping Test Yes Yes Yes
Overload Protection Yes Yes Yes
Phase failure sensitivity Yes Yes Yes
Tripping indication Yes Yes Yes
Tripping Class 10 10 10
Maximum operation per hour Operations/hour 15 15 25
Altitude (m) 2000 2000 2000
Degree of protection IP20 IP20 IP20
Mechanical life span Number of operations 100,000 50,000 50,000
Electrical life span Number of operations 100,000 25,000 25,000
Ambient temperatures allowed
Transport and storage -50...+80ºC -50...+80ºC -50...+80ºC
Operation 3) -20...+70ºC -20...+70ºC -20...+60ºC
Temperature compensation -20...+60ºC -20...+60ºC -20...+60ºC
Resistance to Impact (g) 15 15 25
Standards
IEC/EN 60 947-1. DIN VDE 0660 (part 100) Yes Yes Yes
IEC/EN 60 947-2. DIN VDE 0660 (part 101) Yes Yes Yes
IEC/EN 60 947-4-1. DIN VDE 0660 (part 102) Yes Yes Yes
Terminal capacity
Type of terminal Flat Box Box
Tightening torqueN.m 2...2.5 4...6 4...6
lb.in 18...22 35...55 35...53
Type of screws Philips (Nº2) Allen (4mm) Allen (4mm)
Dimensions
Width (mm) 45 54 70
Height (mm) 97 125 165
Depth (mm) 98 157 171
Altitude Correction Factor
Altitude
(above sea level) - hRated operational voltage U
eCurrent correction factor I
u
h ≤ 2000 m 690 V 1 x Iu
2000 < h ≤ 3000 m 550 V 0,96 x Iu
3000 < h ≤ 4000 m 480 V 0,93 x Iu
4000 < h ≤ 5000 m 420 V 0,90 x Iu
The MPW motor protective circuit breakers do not undergo any
change to their specifi ed performance when applied at an altitude of
up to 2000 meters above sea level.
However, as the altitude increases, the atmospheric properties vary
in terms of dielectric rigidness and pressure.
Therefore, current and voltage correction factors must be applied for
altitudes exceeding 2000 meters, as shown in the table on the left:
Notes: 1) 500V with plastic box;
2) On request: 0 to 400Hz
3) Reduce current for temperatures exceeding +60°C (87% to 70°C)
102
Industrial Control Products4.36
www.pamensky.com
MPW Manual Motor Protector - Technical DataAuxiliary Contact Block - ACB - MPW25 & MPW65
Part Number ACBF-11 ACBS-11. ACBS-20. ACBS-02. TSB
For use with MPW16/16i. MPW25/25i/25t. MPW65/65i
Utilization Category 24 VAC 220-230 VAC 24 VAC 230 VAC 400 VAC 690 VAC
AC-15 2 A 0.5 A 6 A 6 A 3 A 1 A
AC-12 2.5 A 2.5 A 10 A 10 A 10 A 10 A
DC-1324 VDC 48 VDC 60 VDC 24 VDC 110 VDC 220 VDC 440 VDC
1 A 0.3 A 0.15 A 2 A 0.5 A 0.25 A 0.1 A
Type of terminal Flat
Type of screw Philips (Nº2)
Tightening torque 0.8…1.2 N.m (7…10 lb.in)
Rigid cable1 or 2 x (0.5...1.5 mm2). 1 or 2 x (0.75…2.5 mm2). 2 x (18…14 AWG)
Flexible cable
Backup fuses gL/gG 10 A
Auxiliary Contact Block - ACB - MPW100
Part Number ACBF-11 MPW100 ACBS-11/ACBS-20/ACBS-02/TSB AT-11 MPW100
For use with MPW100
Utilization Category 240 VAC 24 VAC 240 VAC
AC-15 3 A 6 A 4 A
DC-1324 VDC 220VDC 24 VDC 220VDC
1 A 0.1 A 2 A 0.25 A
Type of screw Philips (Nº2)
Tightening torque 0.8…1.2 N.m (7…10 lb.in)
Rigid cable 1 (0.5…2.5mm2 / 20…14 AWG) 1 or 2 x (0.5…2.5mm2 / 20…14 AWG)
Flexible cable 1(0.5...4mm2 / 20...10 AWG) or 2(0.75...2.5mm2 / 18...14 AWG)
Back-up fuses gL/gG 16 A
Undervoltage Release - URMP
Part Number URMP URMP V_ _ MPW100
For use with MPW16/16i. MPW25/25i/25t. MPW65/65i MPW100
Operating voltage
(Enables cir. breaker switch ON)0.85...1.1xU
s
Non-operating voltage
(guarantees circuit breaker switch OFF)0.7...0.35xU
s
Energization Consumption 20.2 VA / 13 W 8.5 VA / 6 W
Consumption 7.2 VA / 2.4 W 3 VA / 1.2 W
Max. opening time 20 ms
Type of terminal Flat
Type of screws Philips (Nº2)
Tightening torque 0.8…1.2 N.m (7…10 lb.in)
Rigid cable 1 or 2 x (0.5...1.5 mm2). 1 or 2 x (0.75…2.5 mm2).
2 x (18…14 AWG)
1 or 2 x (0.5...2.5 mm2 / 20...14 AWG)
Flexible cable 1 (0.5...4 mm2 / 20...10 AWG) or 2 x (0.75...2.5 mm2 / 18...14 AWG)
Back-up fuses gL/gG 10 A
Shunt Release - SRMP
Part Number SRMP SRMP-K_ _ MPW100
For use with MPW16/16i. MPW25/25i/25t. MPW65/65i MPW100
Operating Voltage
(guarantee circuit breaker switch OFF)0.7...1.1xUs
Consumption - Energization 20.2 VA / 13 W 8.5 VA / 6 W
Maximum opening time 20 ms
Type of terminal Flat
Type of screw Philips (Nº2)
Tightening torque 0.8…1.2 N.m (7…10 lb.in)
Rigid cable 1 or 2 x (0.5...1.5 mm2). 1 or 2 x (0.75…2.5 mm2)
2 x (18…14 AWG)
1 ou 2 x (0.5...2.5 mm2 / 20...14 AWG)
Flexible cable 1 (0.5...4 mm2 / 20...10 AWG) or 2 x (0.75...2.5 mm2 / 18...14 AWG)
Back-up fuses gL/gG 10 A
102
Industrial Control Products 4.37
www.pamensky.com
WEG has used its leading-edge technology & development capability to design the CSW
series of pushbuttons, pilot lights, selector switches and accessories. These user friendly and
durable Ø22mm pilot devices are used in many industrial applications and environments.
Besides the brightness, the BIDL blocks have many other valuable characteristics, such as:
• Long life expectancy
• Great performance on shock and vibration applications
• Extremely low power consumption and thermal dissipation
• High luminosity and color defi nition (independant of the lens)
Fast and easy assembling system
The Mounting of the contact blocks to the operator (pushbutton, selector switch or indicator)
is done via a snap on fl ange which ensures a fast tight fi t. This system can also be removed
quickly, without tools. Each block can be mounted or removed individually: to assemble,
just snap the components together and a common screwdriver is all that is necessary for
disassembly. The ergonomic design of the new locking ring allows hand tightening, without
the need for a screwdriver.
Contact blocks – safety and reliability
High effi ciency self-cleaning contact blocks; Pure Silver Contacts (Ag100), ensures maximum
reliability in every condition even at low energy levels (5mA/12V). NC Contacts with “Positive
Break” system, ensures circuit interruption.
Pushbuttons and Pilot Lights
102
Industrial Control Products4.38
www.pamensky.com
Flush Color Part Number List Price
White
Red
Green
Yellow
Blue
Black
CSW-BF0
CSW-BF1
CSW-BF2
CSW-BF3
CSW-BF4
CSW-BF5
$6.80
6.80
6.80
6.80
6.80
6.80
Double Color Part Number List Price
N/A CSW-BD $14.30
Illuminated Flush Color Part Number List Price
White
Red
Green
Yellow
Blue
CSW-BFI0
CSW-BFI1
CSW-BFI2
CSW-BFI3
CSW-BFI4
$11.40
11.40
11.40
11.40
11.40
Emergency Stop - Twist Release Color Part Number List Price
Red CSW-BEG $15.10
Pilot Lights Color Part Number List Price
White
Red
Green
Yellow
Blue
CSW-SD0
CSW-SD1
CSW-SD2
CSW-SD3
CSW-SD4
$10.10
10.10
10.10
10.10
10.10
Pushbuttons and Pilot Lights - Table of Products
102
Industrial Control Products 4.39
www.pamensky.com
Pushbuttons and Pilot Lights - Table of Products
KNOB LEVER with KEY(1) ILLUMINATED Colour Code
substitute # for colour code
(see right)
Clear/White 0
Red 1
Green 2
Yellow 3
Blue 4
Part Number List Price Part Number List Price Part Number List Price Part Number List Price POSITION DIAGRAM
CSW-CK2F45 $16 CSW-CA2F45 $17 CSW-CY2F45 $45 1
CSW-CK2R45 18 CSW-CA2R45 19 1
CSW-CK2F90 16 CSW-CA2F90 17 CSW-CKI2F90* $10 2
CSW-CK2R90 18 CSW-CA2R90 19 2
CSW-CK3F45 16 CSW-CA3F45 17 CSW-CY3F45 45 CSW-CKI3F45* 10 3
CSW-CK3R45 18 CSW-CA3R45 19 3
CSW-CK3RE45 18 CSW-CA3RE45 19 3
CSW-CK3RD45 18 CSW-CA3RD45 19 3
(1) Key is released in any position
Substitute CY for CYD for key release on the right only
Substitute CY for CYE for key release on the left only
Substitute CY for CYC for key release in the center only
DIAGRAM 1 DIAGRAM 2 DIAGRAM 3
Handle Position
Contact Status
2 3 1
0
-
I
Handle Position
Contact Status
2 3 1
I
II
Handle Position
Contact Status
2 3 1
0
I
II
Contacts in rest position
Contacts actuated
Mounting position for the LED or lamp blocks only
102
Industrial Control Products4.40
www.pamensky.com
Pushbuttons and Pilot Lights - Assembled UnitsPushbuttons
Description Parts Part Number List Price
Stop pushbutton, 1NC, red CSW-BF1, CSW-BC01 CSW-BF1-01 $12.70
Start pushbutton, 1NO, green CSW-BF2, CSW-BC10 CSW-BF2-10 12.70
pushbutton, 1NO, black CSW-BF5, CSW-BC10 CSW-BF5-10 12.70
Emergency stop pushbutton w/1NC twist release CSW-BEG-01, CSW-BC01 CSW-BEG-01 22.00
Double pushbutton Start/Stop 1NO/1NC CSW-BD, CSW-BC11 CSW-BD-11 26.00
Selector Switches
Description Parts Part Number List Price
2 position selector switch with 1 NO CSW-CK2F45, CSW-BC10 CSW-CK2F45-10 $23.00
3 position selector switch with 2 NO CSW-CK3F45, CSW-BC20 CSW-CK3F45-20 29.00
Pilot Lights
Description Parts Part Number List Price
Pilot light colour red, with LED 110 V CSW-SD1, BIDL110-130VAC1 CSW-SD1-D61 $30.00
Pilot light colour green, with LED 110 V CSW-SD2, BIDL110-130VAC2 CSW-SD2-D61 30.00
Illuminated Pushbutton
Description Parts Part Number List Price
Illuminated pushbutton LED red, 1 NC, 110 V CSW-BFI1, CSW-BC01, BIDL110-130VAC1 CSW-BFI1-01 $37.00
Illuminated pushbutton LED green, 1 NO, 110 V CSW-BFI2, CSW-BC10, BIDL110-130VAC2 CSW-BFI2-10 37.00
102
Industrial Control Products 4.41
www.pamensky.com
Single Contact Block Double Contact Block
1NC
Part Number: CSW-BC01
1NO
Part Number: CSW-BC10
List Price: $5.10
1NO-1NC
Part Number: CSW-BC11
2NO
Part Number: CSW-BC20
List Price: $9.20
Push-on / Push-off Block Full Voltage AC/DC Lamp Block
Part Number: CSW-BR
- Device for fl ush, extended and mushroom push-
buttons
List Price: $8.50
Note: Use only with single contact blocks. 1NO-
-contacts must be CSW-BCA10 (early make) type.
Part Number: CSW-BR
List Price: $8.50
Note: For BA9S lamps
380V / 2W max.
LED Block Colour Code
Part Numbers:
24Vac/Vdc: BIDL24VAC/VDC#
110-130Vac: BIDL110-130VAC#
220-240Vac: BIDL220-240VAC#
List Price: $17.60
Note: Replace # with desired colour code
(see right)
Clear/White 0
Red 1
Green 2
Yellow 3
Blue 4
Pushbuttons and Pilot Lights - Accessories
102
Industrial Control Products4.42
www.pamensky.com
Pushbuttons and Pilot Lights - Technical DataStandards IEC/EN 60947-5-1, VDE 0660, NFC63140, UL 508, UL 50, CENELEC EN50007
Rated insulation voltage 660 Vac / Vdc
Degree of protection IP66 (IEC/EN 60529)
Degree of protection - Terminals IP2X (IEC/EN 60529)
UL ratings Type 1, 2, 3, 3R, 35, 4, 4X, 5, 12, 12K e 13
Electrical ratings
Conventional thermal current Ith = 10A (IEC 947-5-1)
Utilization category AC-15 (V) (A)
24 10
48 10
60 10
110 6
230 3
400 2
500 1.5
600 1.2
Utilization category DC-13 (V) (A)
24 2.5
48 1.4
60 1
110 0.55
230 0.27
400 0.2
600 0.1
UL / CSA ratings
Contacts resistance
AC / Heavy Duty (A600)
DC / Standard Duty (Q600)
≤ 25mΩ (IEC/EN 60255)
Short circuit protection 16A gL/gG fuse or MPW25-10
Electrical shock protection Class II
Rated impulse voltage 2.5 kV (IEC 947-5-1)
Terminal capacity 1 or 2 x (0.5 - 2.5mm2) / 1 or 2 x 14-20AWG
Temperature range -25ºC to 70ºC (-13ºF to 158ºF)
Shock resitance No damage or disassembling at 100g for all devices according to MIL 202 Bmethod 202A ≤ ½ sinusoid 11ms
Vibration resistance 16g with frequency range from 40 to 500Hz
IEC/EN 6068-2-6 and max shifting 0.75mm (peak-to-peak)
Mechanical endurance
Pushbuttons 3 x 106
Selector Switches 1 x 106
Emergency-Stop 3 x 105
Maximum number of contacts AF3 Flange AF5 Flange
Pushbuttons (BF) Max. 6 Max 10
101
Reference 5.1
www.pamensky.com
Variable Frequency Drive Sizing GuideCFW 08 Plus
Motor CFW-08 Plus Variable Frequency Drive Part Number
HP RPM Frame Voltage 230V 460V 575V
1
3600 143T 208-230/460 & 575V CFW080040B2024EON1A1 CFW080026T3848EON1A1 CFW080017T5060EON1A1
1800 143T 208-230/460 & 575V CFW080040B2024EON1A1 CFW080026T3848EON1A1 CFW080017T5060EON1A1
1200 145T 208-230/460 & 575V CFW080040B2024EON1A1 CFW080026T3848EON1A1 CFW080017T5060EON1A1
900 182T 208-230/460 & 575V CFW080040B2024EON1A1 CFW080026T3848EON1A1 CFW080017T5060EON1A1
1.5
3600 143T 208-230/460 & 575V CFW080073B2024EON1A1 CFW080040T3848EON1A1 CFW080030T5060EON1A1
1800 145T 208-230/460 & 575V CFW080073B2024EON1A1 CFW080040T3848EON1A1 CFW080030T5060EON1A1
1200 182T 208-230/460 & 575V CFW080073B2024EON1A1 CFW080040T3848EON1A1 CFW080030T5060EON1A1
900 184T 208-230/460 & 575V CFW080073B2024EON1A1 CFW080040T3848EON1A1 CFW080030T5060EON1A1
2
3600 145T 208-230/460 & 575V CFW080073B2024EON1A1 CFW080043T3848EON1A1 CFW080030T5060EON1A1
1800 145T 208-230/460 & 575V CFW080073B2024EON1A1 CFW080043T3848EON1A1 CFW080030T5060EON1A1
1200 184T 208-230/460 & 575V CFW080073B2024EON1A1 CFW080043T3848EON1A1 CFW080030T5060EON1A1
900 213T 208-230/460 & 575V CFW080073B2024EON1A1 CFW080043T3848EON1A1 CFW080030T5060EON1A1
3
3600 W182T 208-230/460 & 575V CFW080100B2024EON1A1 CFW080065T3848EON1A1 CFW080042T5060EON1A1
1800 W182T 208-230/460 & 575V CFW080100B2024EON1A1 CFW080065T3848EON1A1 CFW080042T5060EON1A1
1200 213T 208-230/460 & 575V CFW080100B2024EON1A1 CFW080065T3848EON1A1 CFW080042T5060EON1A1
900 215T 208-230/460 & 575V CFW080100B2024EON1A1 CFW080065T3848EON1A1 CFW080042T5060EON1A1
5
3600 184T 208-230/460 & 575V CFW080160T2024EON1A1 CFW080100T3848EON1A1 CFW080070T5060EON1A1
1800 184T 208-230/460 & 575V CFW080160T2024EON1A1 CFW080100T3848EON1A1 CFW080070T5060EON1A1
1200 215T 208-230/460 & 575V CFW080160T2024EON1A1 CFW080100T3848EON1A1 CFW080070T5060EON1A1
900 254T 208-230/460 & 575V CFW080160T2024EON1A1 CFW080100T3848EON1A1 CFW080070T5060EON1A1
7.5
3600 213T 208-230/460 & 575V CFW080220T2024EON1A1 CFW080130T3848EON1A1 CFW080100T5060EON1A1
1800 213T 208-230/460 & 575V CFW080220T2024EON1A1 CFW080130T3848EON1A1 CFW080100T5060EON1A1
1200 254T 208-230/460 & 575V CFW080220T2024EON1A1 CFW080130T3848EON1A1 CFW080100T5060EON1A1
900 256T 208-230/460 & 575V CFW080220T2024EON1A1 CFW080130T3848EON1A1 CFW080100T5060EON1A1
10
3600 215T 208-230/460 & 575V CFW080280T2024EON1A1 CFW080160T3848EON1A1 CFW080120T5060EON1A1
1800 215T 208-230/460 & 575V CFW080280T2024EON1A1 CFW080160T3848EON1A1 CFW080120T5060EON1A1
1200 256T 208-230/460 & 575V CFW080280T2024EON1A1 CFW080160T3848EON1A1 CFW080120T5060EON1A1
900 284T 208-230/460 & 575V CFW080280T2024EON1A1 CFW080160T3848EON1A1 CFW080120T5060EON1A1
15
3600 254T 208-230/460 & 575V CFW080240T3848EON1A1
1800 254T 208-230/460 & 575V CFW080240T3848EON1A1
1200 284T 208-230/460 & 575V CFW080240T3848EON1A1
900 286T 208-230/460 & 575V CFW080240T3848EON1A1
20
3600 256T 208-230/460 & 575V CFW080300T3848EON1A1
1800 256T 208-230/460 & 575V CFW080300T3848EON1A1
1200 286T 208-230/460 & 575V CFW080300T3848EON1A1
900 324T 208-230/460 & 575V CFW080300T3848EON1A1
Notes: This chart is designed as a guide only. For specifi c sizing please contact V.J. Pamensky Canada Inc.
101
Reference5.2
www.pamensky.com
Variable Frequency Drive Sizing GuideCFW 09
Motor CFW-09 Variable Frequency Drive Part Number
HP RPM Frame Voltage 230V 460V 575V
1
3600 143T 208-230/460 & 575V CFW090006T2223ESZ CFW090003T3848ESZ CFW090002T5060ESZ
1800 143T 208-230/460 & 575V CFW090006T2223ESZ CFW090003T3848ESZ CFW090002T5060ESZ
1200 145T 208-230/460 & 575V CFW090006T2223ESZ CFW090003T3848ESZ CFW090002T5060ESZ
900 182T 208-230/460 & 575V CFW090006T2223ESZ CFW090003T3848ESZ CFW090002T5060ESZ
1.5
3600 143T 208-230/460 & 575V CFW090006T2223ESZ CFW090003T3848ESZ CFW090002T5060ESZ
1800 145T 208-230/460 & 575V CFW090006T2223ESZ CFW090003T3848ESZ CFW090002T5060ESZ
1200 182T 208-230/460 & 575V CFW090006T2223ESZ CFW090003T3848ESZ CFW090002T5060ESZ
900 184T 208-230/460 & 575V CFW090006T2223ESZ CFW090003T3848ESZ CFW090002T5060ESZ
2
3600 145T 208-230/460 & 575V CFW090007T2223ESZ CFW090004T3848ESZ CFW090002T5060ESZ
1800 145T 208-230/460 & 575V CFW090007T2223ESZ CFW090004T3848ESZ CFW090002T5060ESZ
1200 184T 208-230/460 & 575V CFW090007T2223ESZ CFW090004T3848ESZ CFW090002T5060ESZ
900 213T 208-230/460 & 575V CFW090007T2223ESZ CFW090004T3848ESZ CFW090002T5060ESZ
3
3600 W182T 208-230/460 & 575V CFW090010T2223ESZ CFW090005T3848ESZ CFW090004T5060ESZ
1800 W182T 208-230/460 & 575V CFW090010T2223ESZ CFW090005T3848ESZ CFW090004T5060ESZ
1200 213T 208-230/460 & 575V CFW090010T2223ESZ CFW090005T3848ESZ CFW090004T5060ESZ
900 215T 208-230/460 & 575V CFW090010T2223ESZ CFW090005T3848ESZ CFW090004T5060ESZ
5
3600 184T 208-230/460 & 575V CFW090016T2223ESZ CFW090009T3848ESZ CFW090007T5060ESZ
1800 184T 208-230/460 & 575V CFW090016T2223ESZ CFW090009T3848ESZ CFW090007T5060ESZ
1200 215T 208-230/460 & 575V CFW090016T2223ESZ CFW090009T3848ESZ CFW090007T5060ESZ
900 254T 208-230/460 & 575V CFW090016T2223ESZ CFW090009T3848ESZ CFW090007T5060ESZ
7.5
3600 213T 208-230/460 & 575V CFW090024T2223ESZ CFW090013T3848ESZ CFW090010T5060ESZ
1800 213T 208-230/460 & 575V CFW090024T2223ESZ CFW090013T3848ESZ CFW090010T5060ESZ
1200 254T 208-230/460 & 575V CFW090024T2223ESZ CFW090013T3848ESZ CFW090010T5060ESZ
900 256T 208-230/460 & 575V CFW090024T2223ESZ CFW090013T3848ESZ CFW090010T5060ESZ
10
3600 215T 208-230/460 & 575V CFW090028T2223ESZ CFW090016T3848ESZ CFW090012T5060ESZ
1800 215T 208-230/460 & 575V CFW090028T2223ESZ CFW090016T3848ESZ CFW090012T5060ESZ
1200 256T 208-230/460 & 575V CFW090028T2223ESZ CFW090016T3848ESZ CFW090012T5060ESZ
900 284T 208-230/460 & 575V CFW090028T2223ESZ CFW090016T3848ESZ CFW090012T5060ESZ
15
3600 254T 208-230/460 & 575V CFW090045T2223ESZ CFW090024T3848ESZ CFW090014T5060ESZ
1800 254T 208-230/460 & 575V CFW090045T2223ESZ CFW090024T3848ESZ CFW090014T5060ESZ
1200 284T 208-230/460 & 575V CFW090045T2223ESZ CFW090024T3848ESZ CFW090014T5060ESZ
900 286T 208-230/460 & 575V CFW090045T2223ESZ CFW090024T3848ESZ CFW090014T5060ESZ
20
3600 256T 208-230/460 & 575V CFW090054T2223ESZ CFW090030T3848ESZ CFW090022T5060ESZ
1800 256T 208-230/460 & 575V CFW090054T2223ESZ CFW090030T3848ESZ CFW090022T5060ESZ
1200 286T 208-230/460 & 575V CFW090054T2223ESZ CFW090030T3848ESZ CFW090022T5060ESZ
900 324T 208-230/460 & 575V CFW090054T2223ESZ CFW090030T3848ESZ CFW090022T5060ESZ
25
3600 284TS 208-230/460 & 575V CFW090070T2223ESZ CFW090038T3848ESZ CFW090027T5060ESZ
1800 284T 208-230/460 & 575V CFW090070T2223ESZ CFW090038T3848ESZ CFW090027T5060ESZ
1200 324T 208-230/460 & 575V CFW090070T2223ESZ CFW090038T3848ESZ CFW090027T5060ESZ
900 326T 208-230/460 & 575V CFW090070T2223ESZ CFW090038T3848ESZ CFW090027T5060ESZ
30
3600 286TS 208-230/460 & 575V CFW090086T2223ESZ CFW090045T3848ESZ CFW090032T5060ESZ
1800 286T 208-230/460 & 575V CFW090086T2223ESZ CFW090045T3848ESZ CFW090032T5060ESZ
1200 326T 208-230/460 & 575V CFW090086T2223ESZ CFW090045T3848ESZ CFW090032T5060ESZ
900 364/5T 208-230/460 & 575V CFW090086T2223ESZ CFW090045T3848ESZ CFW090032T5060ESZ
40
3600 324TS 208-230/460 & 575V CFW090105T2223ESZ CFW090060T3848ESZ CFW090044T5060ESZ
1800 324T 208-230/460 & 575V CFW090105T2223ESZ CFW090060T3848ESZ CFW090044T5060ESZ
1200 364/5T 208-230/460 & 575V CFW090105T2223ESZ CFW090060T3848ESZ CFW090044T5060ESZ
900 364/5T 208-230/460 & 575V CFW090105T2223ESZ CFW090060T3848ESZ CFW090044T5060ESZ
50
3600 326TS 208-230/460 & 575V CFW090130T2223ESZ CFW090070T3848ESZ CFW090053T5060ESZ
1800 326T 208-230/460 & 575V CFW090130T2223ESZ CFW090070T3848ESZ CFW090053T5060ESZ
1200 364/5T 208-230/460 & 575V CFW090130T2223ESZ CFW090070T3848ESZ CFW090053T5060ESZ
900 404/5T 208-230/460 & 575V CFW090130T2223ESZ CFW090070T3848ESZ CFW090053T5060ESZ
101
Reference 5.3
www.pamensky.com
Variable Frequency Drive Sizing GuideCFW 09
Motor CFW-09 Variable Frequency Drive Part Number
HP RPM Frame Voltage 230V 460V 575V
60
3600 364/5TS 208-230/460 & 575V CFW090180T2223ESZ CFW090086T3848ESZ CFW090063T5060ESZ
1800 364/5T 208-230/460 & 575V CFW090180T2223ESZ CFW090086T3848ESZ CFW090063T5060ESZ
1200 404/5T 208-230/460 & 575V CFW090180T2223ESZ CFW090086T3848ESZ CFW090063T5060ESZ
900 404/5T 208-230/460 & 575V CFW090180T2223ESZ CFW090086T3848ESZ CFW090063T5060ESZ
75
3600 364/5TS 208-230/460 & 575V CFW090240T2223ESZ CFW090105T3848ESZ CFW090079T5060ESZ
1800 364/5T 208-230/460 & 575V CFW090240T2223ESZ CFW090105T3848ESZ CFW090079T5060ESZ
1200 404/5T 208-230/460 & 575V CFW090240T2223ESZ CFW090105T3848ESZ CFW090079T5060ESZ
900 444/5T 208-230/460 & 575V CFW090240T2223ESZ CFW090105T3848ESZ CFW090079T5060ESZ
100
3600 404/5TS 208-230/460 & 575V CFW090142T3848ESZ CFW090107T5069ESZ
1800 404/5T 208-230/460 & 575V CFW090142T3848ESZ CFW090107T5069ESZ
1200 444/5T 208-230/460 & 575V CFW090142T3848ESZ CFW090107T5069ESZ
900 444/5T 208-230/460 & 575V CFW090142T3848ESZ CFW090107T5069ESZ
125
3600 444/5TS 460 & 575V CFW090180T3848ESZ CFW090147T5069ESZ
1800 444/5T 460 & 575V CFW090180T3848ESZ CFW090147T5069ESZ
1200 444/5T 460 & 575V CFW090180T3848ESZ CFW090147T5069ESZ
900 504/5T 460 & 575V CFW090180T3848ESZ CFW090147T5069ESZ
150
3600 445TS 460 & 575V CFW090180T3848ESZ CFW090147T5069ESZ
1800 445T 460 & 575V CFW090180T3848ESZ CFW090147T5069ESZ
1200 447T 460 & 575V CFW090180T3848ESZ CFW090147T5069ESZ
900 504/5T 460 & 575V CFW090180T3848ESZ CFW090147T5069ESZ
200
3600 447TS 460 & 575V CFW090240T3848ESZ CFW090211T5069ESZ
1800 447T 460 & 575V CFW090240T3848ESZ CFW090211T5069ESZ
1200 447T 460 & 575V CFW090240T3848ESZ CFW090211T5069ESZ
900 449T 460 & 575V CFW090240T3848ESZ CFW090211T5069ESZ
250
3600 447TS 460 & 575V CFW090312T3848ESZ CFW090247T5069ESZ
1800 447T 460 & 575V CFW090312T3848ESZ CFW090247T5069ESZ
1200 586/7T 460 & 575V CFW090312T3848ESZ CFW090247T5069ESZ
900 586/7T 460 & 575V CFW090312T3848ESZ CFW090247T5069ESZ
300
3600 586/7TS 460 & 575V CFW090361T3848ESZ CFW090315T5069ESZ
1800 586/7T 460 & 575V CFW090361T3848ESZ CFW090315T5069ESZ
1200 586/7T 460 & 575V CFW090361T3848ESZ CFW090315T5069ESZ
900 586/7T 460 & 575V CFW090361T3848ESZ CFW090315T5069ESZ
Notes: This chart is designed as a guide only. For specifi c sizing or sizing for larger motors please contact V.J. Pamensky Canada Inc.
101
Reference5.4
www.pamensky.com
Variable Frequency Drive Sizing GuideCFW 11
Motor CFW-11 Variable Frequency Drive Part Number
HP RPM Frame Voltage 230V 460V 575V
1
3600 143T 208-230/460 & 575V CFW110006B2ON1Z CFW110003T40N1Z CFW110002T5ON1NFZ
1800 143T 208-230/460 & 575V CFW110006B2ON1Z CFW110003T40N1Z CFW110002T5ON1NFZ
1200 145T 208-230/460 & 575V CFW110006B2ON1Z CFW110003T40N1Z CFW110002T5ON1NFZ
900 182T 208-230/460 & 575V CFW110006B2ON1Z CFW110003T40N1Z CFW110002T5ON1NFZ
1.5
3600 143T 208-230/460 & 575V CFW110006B2ON1Z CFW110003T40N1Z CFW110002T5ON1NFZ
1800 145T 208-230/460 & 575V CFW110006B2ON1Z CFW110003T40N1Z CFW110002T5ON1NFZ
1200 182T 208-230/460 & 575V CFW110006B2ON1Z CFW110003T40N1Z CFW110002T5ON1NFZ
900 184T 208-230/460 & 575V CFW110006B2ON1Z CFW110003T40N1Z CFW110002T5ON1NFZ
2
3600 145T 208-230/460 & 575V CFW110007B2ON1Z CFW110003T40N1Z CFW110002T5ON1NFZ
1800 145T 208-230/460 & 575V CFW110007B2ON1Z CFW110003T40N1Z CFW110002T5ON1NFZ
1200 184T 208-230/460 & 575V CFW110007B2ON1Z CFW110003T40N1Z CFW110002T5ON1NFZ
900 213T 208-230/460 & 575V CFW110007B2ON1Z CFW110003T40N1Z CFW110002T5ON1NFZ
3
3600 W182T 208-230/460 & 575V CFW110010T2ON1Z CFW110005T40N1Z CFW110004T5ON1NFZ
1800 W182T 208-230/460 & 575V CFW110010T2ON1Z CFW110005T40N1Z CFW110004T5ON1NFZ
1200 213T 208-230/460 & 575V CFW110010T2ON1Z CFW110005T40N1Z CFW110004T5ON1NFZ
900 215T 208-230/460 & 575V CFW110010T2ON1Z CFW110005T40N1Z CFW110004T5ON1NFZ
5
3600 184T 208-230/460 & 575V CFW110024T2ON1Z CFW110010T40N1Z CFW110007T5ON1NFZ
1800 184T 208-230/460 & 575V CFW110024T2ON1Z CFW110010T40N1Z CFW110007T5ON1NFZ
1200 215T 208-230/460 & 575V CFW110024T2ON1Z CFW110010T40N1Z CFW110007T5ON1NFZ
900 254T 208-230/460 & 575V CFW110024T2ON1Z CFW110010T40N1Z CFW110007T5ON1NFZ
7.5
3600 213T 208-230/460 & 575V CFW110028T2ON1Z CFW110017T40N1Z CFW110010T5ON1NFZ
1800 213T 208-230/460 & 575V CFW110028T2ON1Z CFW110017T40N1Z CFW110010T5ON1NFZ
1200 254T 208-230/460 & 575V CFW110028T2ON1Z CFW110017T40N1Z CFW110010T5ON1NFZ
900 256T 208-230/460 & 575V CFW110028T2ON1Z CFW110017T40N1Z CFW110010T5ON1NFZ
10
3600 215T 208-230/460 & 575V CFW110033T2ON1Z CFW110024T40N1Z CFW110012T5ON1NFZ
1800 215T 208-230/460 & 575V CFW110033T2ON1Z CFW110024T40N1Z CFW110012T5ON1NFZ
1200 256T 208-230/460 & 575V CFW110033T2ON1Z CFW110024T40N1Z CFW110012T5ON1NFZ
900 284T 208-230/460 & 575V CFW110033T2ON1Z CFW110024T40N1Z CFW110012T5ON1NFZ
15
3600 254T 208-230/460 & 575V CFW110054T2ON1Z CFW110031T40N1Z CFW110017T5ON1NFZ
1800 254T 208-230/460 & 575V CFW110054T2ON1Z CFW110031T40N1Z CFW110017T5ON1NFZ
1200 284T 208-230/460 & 575V CFW110054T2ON1Z CFW110031T40N1Z CFW110017T5ON1NFZ
900 286T 208-230/460 & 575V CFW110054T2ON1Z CFW110031T40N1Z CFW110017T5ON1NFZ
20
3600 256T 208-230/460 & 575V CFW110070T2ON1Z CFW110038T40N1Z CFW110022T6SZ
1800 256T 208-230/460 & 575V CFW110070T2ON1Z CFW110038T40N1Z CFW110022T6SZ
1200 286T 208-230/460 & 575V CFW110070T2ON1Z CFW110038T40N1Z CFW110022T6SZ
900 324T 208-230/460 & 575V CFW110070T2ON1Z CFW110038T40N1Z CFW110022T6SZ
25
3600 284TS 208-230/460 & 575V CFW110086T2SZ CFW110045T40N1Z CFW110027T6SZ
1800 284T 208-230/460 & 575V CFW110086T2SZ CFW110045T40N1Z CFW110027T6SZ
1200 324T 208-230/460 & 575V CFW110086T2SZ CFW110045T40N1Z CFW110027T6SZ
900 326T 208-230/460 & 575V CFW110086T2SZ CFW110045T40N1Z CFW110027T6SZ
30
3600 286TS 208-230/460 & 575V CFW110105T2SZ CFW110058T40N1Z CFW110032T6SZ
1800 286T 208-230/460 & 575V CFW110105T2SZ CFW110058T40N1Z CFW110032T6SZ
1200 326T 208-230/460 & 575V CFW110105T2SZ CFW110058T40N1Z CFW110032T6SZ
900 364/5T 208-230/460 & 575V CFW110105T2SZ CFW110058T40N1Z CFW110032T6SZ
40
3600 324TS 208-230/460 & 575V CFW110142T2SZ CFW110070T4SZ CFW110044T6SZ
1800 324T 208-230/460 & 575V CFW110142T2SZ CFW110070T4SZ CFW110044T6SZ
1200 364/5T 208-230/460 & 575V CFW110142T2SZ CFW110070T4SZ CFW110044T6SZ
900 364/5T 208-230/460 & 575V CFW110142T2SZ CFW110070T4SZ CFW110044T6SZ
50
3600 326TS 208-230/460 & 575V CFW110180T2ON1Z CFW110088T4SZ CFW110053T6ON1NBYZ
1800 326T 208-230/460 & 575V CFW110180T2ON1Z CFW110088T4SZ CFW110053T6ON1NBYZ
1200 364/5T 208-230/460 & 575V CFW110180T2ON1Z CFW110088T4SZ CFW110053T6ON1NBYZ
900 404/5T 208-230/460 & 575V CFW110180T2ON1Z CFW110088T4SZ CFW110053T6ON1NBYZ
101
Reference 5.5
www.pamensky.com
Variable Frequency Drive Sizing GuideCFW 11
Motor CFW-11 Variable Frequency Drive Part Number
HP RPM Frame Voltage 230V 460V 575V
60
3600 364/5TS 208-230/460 & 575V CFW110211T2ON1Z CFW110105T40N1Z CFW110063T6ON1NBYZ
1800 364/5T 208-230/460 & 575V CFW110211T2ON1Z CFW110105T40N1Z CFW110063T6ON1NBYZ
1200 404/5T 208-230/460 & 575V CFW110211T2ON1Z CFW110105T40N1Z CFW110063T6ON1NBYZ
900 404/5T 208-230/460 & 575V CFW110211T2ON1Z CFW110105T40N1Z CFW110063T6ON1NBYZ
75
3600 364/5TS 208-230/460 & 575V CFW110142T40N1Z CFW110080T6ON1NBYZ
1800 364/5T 208-230/460 & 575V CFW110142T40N1Z CFW110080T6ON1NBYZ
1200 404/5T 208-230/460 & 575V CFW110142T40N1Z CFW110080T6ON1NBYZ
900 444/5T 208-230/460 & 575V CFW110142T40N1Z CFW110080T6ON1NBYZ
100
3600 404/5TS 208-230/460 & 575V CFW110180T40N1Z CFW110107T6ON1NBYZ
1800 404/5T 208-230/460 & 575V CFW110180T40N1Z CFW110107T6ON1NBYZ
1200 444/5T 208-230/460 & 575V CFW110180T40N1Z CFW110107T6ON1NBYZ
900 444/5T 208-230/460 & 575V CFW110180T40N1Z CFW110107T6ON1NBYZ
125
3600 444/5TS 460 & 575V CFW110211T40N1Z CFW110125T6ON1NBYZ
1800 444/5T 460 & 575V CFW110211T40N1Z CFW110125T6ON1NBYZ
1200 444/5T 460 & 575V CFW110211T40N1Z CFW110125T6ON1NBYZ
900 504/5T 460 & 575V CFW110211T40N1Z CFW110125T6ON1NBYZ
150
3600 445TS 460 & 575V CFW110242T4SZ CFW110150T6ON1NBYZ
1800 445T 460 & 575V CFW110242T4SZ CFW110150T6ON1NBYZ
1200 447T 460 & 575V CFW110242T4SZ CFW110150T6ON1NBYZ
900 504/5T 460 & 575V CFW110242T4SZ CFW110150T6ON1NBYZ
200
3600 447TS 460 & 575V CFW110312T4SZ CFW110216T6ONBYZ
1800 447T 460 & 575V CFW110312T4SZ CFW110216T6ONBYZ
1200 447T 460 & 575V CFW110312T4SZ CFW110216T6ONBYZ
900 449T 460 & 575V CFW110312T4SZ CFW110216T6ONBYZ
250
3600 447TS 460 & 575V CFW110370T4SZ CFW110289T6ONBYZ
1800 447T 460 & 575V CFW110370T4SZ CFW110289T6ONBYZ
1200 586/7T 460 & 575V CFW110370T4SZ CFW110289T6ONBYZ
900 586/7T 460 & 575V CFW110370T4SZ CFW110289T6ONBYZ
300
3600 586/7TS 460 & 575V CFW110477T4SZ CFW110315T6ONBYZ
1800 586/7T 460 & 575V CFW110477T4SZ CFW110315T6ONBYZ
1200 586/7T 460 & 575V CFW110477T4SZ CFW110315T6ONBYZ
900 586/7T 460 & 575V CFW110477T4SZ CFW110315T6ONBYZ
Notes: This chart uses Normal Duty (ND) ratings for sizing. See CFW-11 product table for more information.
This chart is designed as a guide only. For specifi c sizing or sizing for larger motors please contact V.J. Pamensky Canada Inc.
101
Reference5.6
www.pamensky.com
Variable Frequency Drive Sizing GuideCFW 700
Motor CFW-700 Variable Frequency Drive Part Number
HP RPM Frame Voltage 230V 460V 575V
1
3600 143T 208-230/460 & 575V CFW700A06POB2DBN1 CFW700A03P6T4DBN1 CFW700B02P9T5DBN1
1800 143T 208-230/460 & 575V CFW700A06POB2DBN1 CFW700A03P6T4DBN1 CFW700B02P9T5DBN1
1200 145T 208-230/460 & 575V CFW700A06POB2DBN1 CFW700A03P6T4DBN1 CFW700B02P9T5DBN1
900 182T 208-230/460 & 575V CFW700A06POB2DBN1 CFW700A03P6T4DBN1 CFW700B02P9T5DBN1
1.5
3600 143T 208-230/460 & 575V CFW700A06POB2DBN1 CFW700A03P6T4DBN1 CFW700B02P9T5DBN1
1800 145T 208-230/460 & 575V CFW700A06POB2DBN1 CFW700A03P6T4DBN1 CFW700B02P9T5DBN1
1200 182T 208-230/460 & 575V CFW700A06POB2DBN1 CFW700A03P6T4DBN1 CFW700B02P9T5DBN1
900 184T 208-230/460 & 575V CFW700A06POB2DBN1 CFW700A03P6T4DBN1 CFW700B02P9T5DBN1
2
3600 145T 208-230/460 & 575V CFW700A07POB2DBN1 CFW700A03P6T4DBN1 CFW700B02P9T5DBN1
1800 145T 208-230/460 & 575V CFW700A07POB2DBN1 CFW700A03P6T4DBN1 CFW700B02P9T5DBN1
1200 184T 208-230/460 & 575V CFW700A07POB2DBN1 CFW700A03P6T4DBN1 CFW700B02P9T5DBN1
900 213T 208-230/460 & 575V CFW700A07POB2DBN1 CFW700A03P6T4DBN1 CFW700B02P9T5DBN1
3
3600 W182T 208-230/460 & 575V CFW700A10POT2DBN1 CFW700A05P0T4DBN1 CFW700B04P2T5DBN1
1800 W182T 208-230/460 & 575V CFW700A10POT2DBN1 CFW700A05P0T4DBN1 CFW700B04P2T5DBN1
1200 213T 208-230/460 & 575V CFW700A10POT2DBN1 CFW700A05P0T4DBN1 CFW700B04P2T5DBN1
900 215T 208-230/460 & 575V CFW700A10POT2DBN1 CFW700A05P0T4DBN1 CFW700B04P2T5DBN1
5
3600 184T 208-230/460 & 575V CFW700B24POT2DBN1 CFW700A10P0T4DBN1 CFW700B07P0T5DBN1
1800 184T 208-230/460 & 575V CFW700B24POT2DBN1 CFW700A10P0T4DBN1 CFW700B07P0T5DBN1
1200 215T 208-230/460 & 575V CFW700B24POT2DBN1 CFW700A10P0T4DBN1 CFW700B07P0T5DBN1
900 254T 208-230/460 & 575V CFW700B24POT2DBN1 CFW700A10P0T4DBN1 CFW700B07P0T5DBN1
7.5
3600 213T 208-230/460 & 575V CFW700B28POT2DBN1 CFW700B17P0T4DBN1 CFW700B10P0T5DBN1
1800 213T 208-230/460 & 575V CFW700B28POT2DBN1 CFW700B17P0T4DBN1 CFW700B10P0T5DBN1
1200 254T 208-230/460 & 575V CFW700B28POT2DBN1 CFW700B17P0T4DBN1 CFW700B10P0T5DBN1
900 256T 208-230/460 & 575V CFW700B28POT2DBN1 CFW700B17P0T4DBN1 CFW700B10P0T5DBN1
10
3600 215T 208-230/460 & 575V CFW700B33POT2DBN1 CFW700B24P0T4DBN1 CFW700B12P0T5DBN1
1800 215T 208-230/460 & 575V CFW700B33POT2DBN1 CFW700B24P0T4DBN1 CFW700B12P0T5DBN1
1200 256T 208-230/460 & 575V CFW700B33POT2DBN1 CFW700B24P0T4DBN1 CFW700B12P0T5DBN1
900 284T 208-230/460 & 575V CFW700B33POT2DBN1 CFW700B24P0T4DBN1 CFW700B12P0T5DBN1
15
3600 254T 208-230/460 & 575V CFW700C54POT2DBN1 CFW700B31P0T4DBN1 CFW700B17P0T5DBN1
1800 254T 208-230/460 & 575V CFW700C54POT2DBN1 CFW700B31P0T4DBN1 CFW700B17P0T5DBN1
1200 284T 208-230/460 & 575V CFW700C54POT2DBN1 CFW700B31P0T4DBN1 CFW700B17P0T5DBN1
900 286T 208-230/460 & 575V CFW700C54POT2DBN1 CFW700B31P0T4DBN1 CFW700B17P0T5DBN1
20
3600 256T 208-230/460 & 575V CFW700C70POT2DBN1 CFW700C38P0T4DBN1 CFW700D22P0T5NBN1
1800 256T 208-230/460 & 575V CFW700C70POT2DBN1 CFW700C38P0T4DBN1 CFW700D22P0T5NBN1
1200 286T 208-230/460 & 575V CFW700C70POT2DBN1 CFW700C38P0T4DBN1 CFW700D22P0T5NBN1
900 324T 208-230/460 & 575V CFW700C70POT2DBN1 CFW700C38P0T4DBN1 CFW700D22P0T5NBN1
25
3600 284TS 208-230/460 & 575V CFW700D86POT2DBN1 CFW700C45P0T4DBN1 CFW700D27P0T5NBN1
1800 284T 208-230/460 & 575V CFW700D86POT2DBN1 CFW700C45P0T4DBN1 CFW700D27P0T5NBN1
1200 324T 208-230/460 & 575V CFW700D86POT2DBN1 CFW700C45P0T4DBN1 CFW700D27P0T5NBN1
900 326T 208-230/460 & 575V CFW700D86POT2DBN1 CFW700C45P0T4DBN1 CFW700D27P0T5NBN1
30
3600 286TS 208-230/460 & 575V CFW700D0105T2DBN1 CFW700C58P5T4DBN1 CFW700D32P0T5NBN1
1800 286T 208-230/460 & 575V CFW700D0105T2DBN1 CFW700C58P5T4DBN1 CFW700D32P0T5NBN1
1200 326T 208-230/460 & 575V CFW700D0105T2DBN1 CFW700C58P5T4DBN1 CFW700D32P0T5NBN1
900 364/5T 208-230/460 & 575V CFW700D0105T2DBN1 CFW700C58P5T4DBN1 CFW700D32P0T5NBN1
40
3600 324TS 208-230/460 & 575V CFW700E0142T2NBN1C3 CFW700D70P5T4DBN1 CFW700D44P0T5NBN1
1800 324T 208-230/460 & 575V CFW700E0142T2NBN1C3 CFW700D70P5T4DBN1 CFW700D44P0T5NBN1
1200 364/5T 208-230/460 & 575V CFW700E0142T2NBN1C3 CFW700D70P5T4DBN1 CFW700D44P0T5NBN1
900 364/5T 208-230/460 & 575V CFW700E0142T2NBN1C3 CFW700D70P5T4DBN1 CFW700D44P0T5NBN1
50
3600 326TS 208-230/460 & 575V CFW700E0180T2NBN1C3 CFW700D88P0T4DBN1 CFW700E53P0T5NBN1C3
1800 326T 208-230/460 & 575V CFW700E0180T2NBN1C3 CFW700D88P0T4DBN1 CFW700E53P0T5NBN1C3
1200 364/5T 208-230/460 & 575V CFW700E0180T2NBN1C3 CFW700D88P0T4DBN1 CFW700E53P0T5NBN1C3
900 404/5T 208-230/460 & 575V CFW700E0180T2NBN1C3 CFW700D88P0T4DBN1 CFW700E53P0T5NBN1C3
101
Reference 5.7
www.pamensky.com
Variable Frequency Drive Sizing GuideCFW 700
Motor CFW-700 Variable Frequency Drive Part Number
HP RPM Frame Voltage 230V 460V 575V
60
3600 364/5TS 208-230/460 & 575V CFW700E0211T2NBN1C3 CFW700E0105T4NBN1C3 CFW700E63P0T5NBN1C3
1800 364/5T 208-230/460 & 575V CFW700E0211T2NBN1C3 CFW700E0105T4NBN1C3 CFW700E63P0T5NBN1C3
1200 404/5T 208-230/460 & 575V CFW700E0211T2NBN1C3 CFW700E0105T4NBN1C3 CFW700E63P0T5NBN1C3
900 404/5T 208-230/460 & 575V CFW700E0211T2NBN1C3 CFW700E0105T4NBN1C3 CFW700E63P0T5NBN1C3
75
3600 364/5TS 208-230/460 & 575V CFW700E0142T4NBN1C3 CFW700E80P0T5NBN1C3
1800 364/5T 208-230/460 & 575V CFW700E0142T4NBN1C3 CFW700E80P0T5NBN1C3
1200 404/5T 208-230/460 & 575V CFW700E0142T4NBN1C3 CFW700E80P0T5NBN1C3
900 444/5T 208-230/460 & 575V CFW700E0142T4NBN1C3 CFW700E80P0T5NBN1C3
100
3600 404/5TS 208-230/460 & 575V CFW700E0180T4NBN1C3 CFW700E0107T5NBN1C3
1800 404/5T 208-230/460 & 575V CFW700E0180T4NBN1C3 CFW700E0107T5NBN1C3
1200 444/5T 208-230/460 & 575V CFW700E0180T4NBN1C3 CFW700E0107T5NBN1C3
900 444/5T 208-230/460 & 575V CFW700E0180T4NBN1C3 CFW700E0107T5NBN1C3
125
3600 444/5TS 460 & 575V CFW700E0211T4NBN1C3 CFW700E0125T5NBN1C3
1800 444/5T 460 & 575V CFW700E0211T4NBN1C3 CFW700E0125T5NBN1C3
1200 444/5T 460 & 575V CFW700E0211T4NBN1C3 CFW700E0125T5NBN1C3
900 504/5T 460 & 575V CFW700E0211T4NBN1C3 CFW700E0125T5NBN1C3
150
3600 445TS 460 & 575V CFW700E0150T5NBN1C3
1800 445T 460 & 575V CFW700E0150T5NBN1C3
1200 447T 460 & 575V CFW700E0150T5NBN1C3
900 504/5T 460 & 575V CFW700E0150T5NBN1C3
Notes: This chart uses Normal Duty (ND) ratings for sizing. See CFW-700 product table for more information.
This chart is designed as a guide only. For specifi c sizing please contact V.J. Pamensky Canada Inc.
101
Reference5.8
www.pamensky.com
Direct On-Line Starter Sizing GuidePESW
Motor PESW Direct On-Line Starter Part Number
HP RPM Frame Voltage 230V 460V 575V
1
3600 143T 208-230/460 & 575V PESW-9V24AX-R26 PESW-9V47AX-R24 PESW-9V56AX-R24
1800 143T 208-230/460 & 575V PESW-9V24AX-R26 PESW-9V47AX-R24 PESW-9V56AX-R24
1200 145T 208-230/460 & 575V PESW-9V24AX-R26 PESW-9V47AX-R24 PESW-9V56AX-R24
900 182T 208-230/460 & 575V PESW-9V24AX-R26 PESW-9V47AX-R24 PESW-9V56AX-R24
1.5
3600 143T 208-230/460 & 575V PESW-9V24AX-R27 PESW-9V47AX-R25 PESW-9V56AX-R25
1800 145T 208-230/460 & 575V PESW-9V24AX-R27 PESW-9V47AX-R25 PESW-9V56AX-R25
1200 182T 208-230/460 & 575V PESW-9V24AX-R27 PESW-9V47AX-R25 PESW-9V56AX-R25
900 184T 208-230/460 & 575V PESW-9V24AX-R27 PESW-9V47AX-R25 PESW-9V56AX-R25
2
3600 145T 208-230/460 & 575V PESW-9V24AX-R28 PESW-9V47AX-R26 PESW-9V56AX-R25
1800 145T 208-230/460 & 575V PESW-9V24AX-R28 PESW-9V47AX-R26 PESW-9V56AX-R25
1200 184T 208-230/460 & 575V PESW-9V24AX-R28 PESW-9V47AX-R26 PESW-9V56AX-R25
900 213T 208-230/460 & 575V PESW-9V24AX-R28 PESW-9V47AX-R26 PESW-9V56AX-R25
3
3600 W182T 208-230/460 & 575V PESW-9V24AX-R29 PESW-9V47AX-R27 PESW-9V56AX-R26
1800 W182T 208-230/460 & 575V PESW-9V24AX-R29 PESW-9V47AX-R27 PESW-9V56AX-R26
1200 213T 208-230/460 & 575V PESW-9V24AX-R29 PESW-9V47AX-R27 PESW-9V56AX-R26
900 215T 208-230/460 & 575V PESW-9V24AX-R29 PESW-9V47AX-R27 PESW-9V56AX-R26
5
3600 184T 208-230/460 & 575V PESW-18V24AX-R32 PESW-9V47AX-R28 PESW-9V56AX-R27
1800 184T 208-230/460 & 575V PESW-18V24AX-R32 PESW-9V47AX-R28 PESW-9V56AX-R27
1200 215T 208-230/460 & 575V PESW-18V24AX-R32 PESW-9V47AX-R28 PESW-9V56AX-R27
900 254T 208-230/460 & 575V PESW-18V24AX-R32 PESW-9V47AX-R28 PESW-9V56AX-R27
7.5
3600 213T 208-230/460 & 575V PESW-25V24AX-R33 PESW-12V47AX-R30 PESW-9V56AX-R29
1800 213T 208-230/460 & 575V PESW-25V24AX-R33 PESW-12V47AX-R30 PESW-9V56AX-R29
1200 254T 208-230/460 & 575V PESW-25V24AX-R33 PESW-12V47AX-R30 PESW-9V56AX-R29
900 256T 208-230/460 & 575V PESW-32V24AX-R33 PESW-12V47AX-R30 PESW-9V56AX-R29
10
3600 215T 208-230/460 & 575V PESW-32V24AX-R34 PESW-18V47AX-R32 PESW-12V56AX-R30
1800 215T 208-230/460 & 575V PESW-32V24AX-R34 PESW-18V47AX-R32 PESW-12V56AX-R30
1200 256T 208-230/460 & 575V PESW-32V24AX-R34 PESW-18V47AX-R32 PESW-12V56AX-R30
900 284T 208-230/460 & 575V PESW-32V24AX-R34 PESW-18V47AX-R32 PESW-12V56AX-R30
15
3600 254T 208-230/460 & 575V PESW-40V24AX-R35 PESW-25V47AX-R33 PESW-18V56AX-R32
1800 254T 208-230/460 & 575V PESW-40V24AX-R35 PESW-25V47AX-R33 PESW-18V56AX-R32
1200 284T 208-230/460 & 575V PESW-40V24AX-R35 PESW-25V47AX-R33 PESW-18V56AX-R32
900 286T 208-230/460 & 575V PESW-50V24AX-R36 PESW-32V47AX-R33 PESW-18V56AX-R32
20
3600 256T 208-230/460 & 575V PESW-65V24AX-R39 PESW-32V47AX-R34 PESW-32V56AX-R33
1800 256T 208-230/460 & 575V PESW-65V24AX-R39 PESW-32V47AX-R34 PESW-32V56AX-R33
1200 286T 208-230/460 & 575V PESW-65V24AX-R39 PESW-32V47AX-R34 PESW-32V56AX-R33
900 324T 208-230/460 & 575V PESW-65V24AX-R39 PESW-32V47AX-R34 PESW-32V56AX-R33
25
3600 284TS 208-230/460 & 575V PESW-80V24AX-R41 PESW-40V47AX-R35 PESW-32V56AX-R34
1800 284T 208-230/460 & 575V PESW-80V24AX-R41 PESW-40V47AX-R35 PESW-32V56AX-R34
1200 324T 208-230/460 & 575V PESW-80V24AX-R41 PESW-40V47AX-R35 PESW-32V56AX-R34
900 326T 208-230/460 & 575V PESW-80V24AX-R41 PESW-50V47AX-R36 PESW-32V56AX-R34
30
3600 286TS 208-230/460 & 575V PESW-95V24AX-R43 PESW-50V47AX-R36 PESW-50V56AX-R36
1800 286T 208-230/460 & 575V PESW-95V24AX-R43 PESW-50V47AX-R38 PESW-50V56AX-R36
1200 326T 208-230/460 & 575V PESW-95V24AX-R43 PESW-50V47AX-R38 PESW-50V56AX-R36
900 364/5T 208-230/460 & 575V PESW-95V24AX-R43 PESW-50V47AX-R38 PESW-50V56AX-R36
40
3600 324TS 208-230/460 & 575V PESW-105V24AX-R45 PESW-65V47AX-R39 PESW-50V56AX-R38
1800 324T 208-230/460 & 575V PESW-105V24AX-R45 PESW-65V47AX-R39 PESW-50V56AX-R38
1200 364/5T 208-230/460 & 575V PESW-105V24AX-R45 PESW-65V47AX-R39 PESW-50V56AX-R38
900 364/5T 208-230/460 & 575V PESW-105V24AX-R45 PESW-65V47AX-R39 PESW-50V56AX-R38
50
3600 326TS 208-230/460 & 575V PESW-80V47AX-R41 PESW-65V56AX-R39
1800 326T 208-230/460 & 575V PESW-80V47AX-R41 PESW-65V56AX-R39
1200 364/5T 208-230/460 & 575V PESW-80V47AX-R41 PESW-65V56AX-R39
900 404/5T 208-230/460 & 575V PESW-80V47AX-R41 PESW-65V56AX-R39
101
Reference 5.9
www.pamensky.com
Direct On-Line Starter Sizing GuidePESW
Motor PESW Direct On-Line Starter Part Number
HP RPM Frame Voltage 230V 460V 575V
60
3600 364/5TS 208-230/460 & 575V PESW-95V47AX-R43 PESW-80V56AX-R41
1800 364/5T 208-230/460 & 575V PESW-95V47AX-R43 PESW-80V56AX-R41
1200 404/5T 208-230/460 & 575V PESW-95V47AX-R43 PESW-80V56AX-R41
900 404/5T 208-230/460 & 575V PESW-95V47AX-R43 PESW-80V56AX-R41
75
3600 364/5TS 208-230/460 & 575V PESW-105V47AX-R44 PESW-95V56AX-R43
1800 364/5T 208-230/460 & 575V PESW-105V47AX-R44 PESW-95V56AX-R43
1200 404/5T 208-230/460 & 575V PESW-105V47AX-R44 PESW-95V56AX-R43
900 444/5T 208-230/460 & 575V PESW-105V47AX-R44 PESW-95V56AX-R43
Notes: This chart is designed as a guide only. For specifi c sizing please contact V.J. Pamensky Canada Inc.
101
Reference5.10
www.pamensky.com
Soft Starter Sizing GuideSSW 06
Motor SSW 06 Soft Starter Part Number
HP RPM Frame Voltage 230V 460V 575V
1
3600 143T 208-230/460 & 575V SSW060010T2257ESZ
1800 143T 208-230/460 & 575V SSW060010T2257ESZ
1200 145T 208-230/460 & 575V SSW060010T2257ESZ
900 182T 208-230/460 & 575V SSW060010T2257ESZ
1.5
3600 143T 208-230/460 & 575V SSW060010T2257ESZ
1800 145T 208-230/460 & 575V SSW060010T2257ESZ
1200 182T 208-230/460 & 575V SSW060010T2257ESZ
900 184T 208-230/460 & 575V SSW060010T2257ESZ
2
3600 145T 208-230/460 & 575V SSW060010T2257ESZ
1800 145T 208-230/460 & 575V SSW060010T2257ESZ
1200 184T 208-230/460 & 575V SSW060010T2257ESZ
900 213T 208-230/460 & 575V SSW060010T2257ESZ
3
3600 W182T 208-230/460 & 575V SSW060010T2257ESZ SSW060010T2257ESZ SSW060010T5257ESZ
1800 W182T 208-230/460 & 575V SSW060010T2257ESZ SSW060010T2257ESZ SSW060010T5257ESZ
1200 213T 208-230/460 & 575V SSW060010T2257ESZ SSW060010T2257ESZ SSW060010T5257ESZ
900 215T 208-230/460 & 575V SSW060010T2257ESZ SSW060010T2257ESZ SSW060010T5257ESZ
5
3600 184T 208-230/460 & 575V SSW060016T2257ESZ SSW060010T2257ESZ SSW060010T5257ESZ
1800 184T 208-230/460 & 575V SSW060016T2257ESZ SSW060010T2257ESZ SSW060010T5257ESZ
1200 215T 208-230/460 & 575V SSW060016T2257ESZ SSW060010T2257ESZ SSW060010T5257ESZ
900 254T 208-230/460 & 575V SSW060016T2257ESZ SSW060010T2257ESZ SSW060010T5257ESZ
7.5
3600 213T 208-230/460 & 575V SSW060023T2257ESZ SSW060016T2257ESZ SSW060010T5257ESZ
1800 213T 208-230/460 & 575V SSW060023T2257ESZ SSW060016T2257ESZ SSW060010T5257ESZ
1200 254T 208-230/460 & 575V SSW060023T2257ESZ SSW060016T2257ESZ SSW060010T5257ESZ
900 256T 208-230/460 & 575V SSW060023T2257ESZ SSW060016T2257ESZ SSW060010T5257ESZ
10
3600 215T 208-230/460 & 575V SSW060030T2257ESZ SSW060016T2257ESZ SSW060016T5257ESZ
1800 215T 208-230/460 & 575V SSW060030T2257ESZ SSW060016T2257ESZ SSW060016T5257ESZ
1200 256T 208-230/460 & 575V SSW060030T2257ESZ SSW060016T2257ESZ SSW060016T5257ESZ
900 284T 208-230/460 & 575V SSW060030T2257ESZ SSW060016T2257ESZ SSW060016T5257ESZ
15
3600 254T 208-230/460 & 575V SSW060045T2257ESZ SSW060023T2257ESZ SSW060016T5257ESZ
1800 254T 208-230/460 & 575V SSW060045T2257ESZ SSW060023T2257ESZ SSW060016T5257ESZ
1200 284T 208-230/460 & 575V SSW060045T2257ESZ SSW060023T2257ESZ SSW060016T5257ESZ
900 286T 208-230/460 & 575V SSW060045T2257ESZ SSW060023T2257ESZ SSW060016T5257ESZ
20
3600 256T 208-230/460 & 575V SSW060060T2257ESZ SSW060030T2257ESZ SSW060023T5257ESZ
1800 256T 208-230/460 & 575V SSW060060T2257ESZ SSW060030T2257ESZ SSW060023T5257ESZ
1200 286T 208-230/460 & 575V SSW060060T2257ESZ SSW060030T2257ESZ SSW060023T5257ESZ
900 324T 208-230/460 & 575V SSW060060T2257ESZ SSW060030T2257ESZ SSW060023T5257ESZ
25
3600 284TS 208-230/460 & 575V SSW060085T2257ESZ SSW060045T2257ESZ SSW060030T5257ESZ
1800 284T 208-230/460 & 575V SSW060085T2257ESZ SSW060045T2257ESZ SSW060030T5257ESZ
1200 324T 208-230/460 & 575V SSW060085T2257ESZ SSW060045T2257ESZ SSW060030T5257ESZ
900 326T 208-230/460 & 575V SSW060085T2257ESZ SSW060045T2257ESZ SSW060030T5257ESZ
30
3600 286TS 208-230/460 & 575V SSW060085T2257ESZ SSW060045T2257ESZ SSW060030T5257ESZ
1800 286T 208-230/460 & 575V SSW060085T2257ESZ SSW060045T2257ESZ SSW060030T5257ESZ
1200 326T 208-230/460 & 575V SSW060085T2257ESZ SSW060045T2257ESZ SSW060030T5257ESZ
900 364/5T 208-230/460 & 575V SSW060085T2257ESZ SSW060045T2257ESZ SSW060030T5257ESZ
40
3600 324TS 208-230/460 & 575V SSW060130T2257ESZ SSW060060T2257ESZ SSW060045T5257ESZ
1800 324T 208-230/460 & 575V SSW060130T2257ESZ SSW060060T2257ESZ SSW060045T5257ESZ
1200 364/5T 208-230/460 & 575V SSW060130T2257ESZ SSW060060T2257ESZ SSW060045T5257ESZ
900 364/5T 208-230/460 & 575V SSW060130T2257ESZ SSW060060T2257ESZ SSW060045T5257ESZ
50
3600 326TS 208-230/460 & 575V SSW060130T2257ESZ SSW060085T2257ESZ SSW060060T5257ESZ
1800 326T 208-230/460 & 575V SSW060130T2257ESZ SSW060085T2257ESZ SSW060060T5257ESZ
1200 364/5T 208-230/460 & 575V SSW060130T2257ESZ SSW060085T2257ESZ SSW060060T5257ESZ
900 404/5T 208-230/460 & 575V SSW060130T2257ESZ SSW060085T2257ESZ SSW060060T5257ESZ
101
Reference 5.11
www.pamensky.com
Soft Starter Sizing GuideSSW 06
Motor SSW 06 Soft Starter Part Number
HP RPM Frame Voltage 230V 460V 575V
60
3600 364/5TS 208-230/460 & 575V SSW060170T2257ESZ SSW060085T2257ESZ SSW060060T5257ESZ
1800 364/5T 208-230/460 & 575V SSW060170T2257ESZ SSW060085T2257ESZ SSW060060T5257ESZ
1200 404/5T 208-230/460 & 575V SSW060170T2257ESZ SSW060085T2257ESZ SSW060060T5257ESZ
900 404/5T 208-230/460 & 575V SSW060170T2257ESZ SSW060085T2257ESZ SSW060060T5257ESZ
75
3600 364/5TS 208-230/460 & 575V SSW060205T2257ESZ SSW060130T2257ESZ SSW060085T5257ESZ
1800 364/5T 208-230/460 & 575V SSW060205T2257ESZ SSW060130T2257ESZ SSW060085T5257ESZ
1200 404/5T 208-230/460 & 575V SSW060205T2257ESZ SSW060130T2257ESZ SSW060085T5257ESZ
900 444/5T 208-230/460 & 575V SSW060205T2257ESZ SSW060130T2257ESZ SSW060085T5257ESZ
100
3600 404/5TS 208-230/460 & 575V SSW060255T2257ESZ SSW060130T2257ESZ SSW060130T5257ESZ
1800 404/5T 208-230/460 & 575V SSW060255T2257ESZ SSW060130T2257ESZ SSW060130T5257ESZ
1200 444/5T 208-230/460 & 575V SSW060255T2257ESZ SSW060130T2257ESZ SSW060130T5257ESZ
900 444/5T 208-230/460 & 575V SSW060255T2257ESZ SSW060130T2257ESZ SSW060130T5257ESZ
125
3600 444/5TS 460 & 575V SSW060312T2257ESZ SSW060170T2257ESZ SSW060130T5257ESZ
1800 444/5T 460 & 575V SSW060312T2257ESZ SSW060170T2257ESZ SSW060130T5257ESZ
1200 444/5T 460 & 575V SSW060312T2257ESZ SSW060170T2257ESZ SSW060130T5257ESZ
900 504/5T 460 & 575V SSW060312T2257ESZ SSW060170T2257ESZ SSW060130T5257ESZ
150
3600 445TS 460 & 575V SSW060365T2257ESZ SSW060205T2257ESZ SSW060170T5257ESZ
1800 445T 460 & 575V SSW060365T2257ESZ SSW060205T2257ESZ SSW060170T5257ESZ
1200 447T 460 & 575V SSW060365T2257ESZ SSW060205T2257ESZ SSW060170T5257ESZ
900 504/5T 460 & 575V SSW060365T2257ESZ SSW060205T2257ESZ SSW060170T5257ESZ
200
3600 447TS 460 & 575V SSW060480T2257ESZ SSW060255T2257ESZ SSW060205T5257ESZ
1800 447T 460 & 575V SSW060480T2257ESZ SSW060255T2257ESZ SSW060205T5257ESZ
1200 447T 460 & 575V SSW060480T2257ESZ SSW060255T2257ESZ SSW060205T5257ESZ
900 449T 460 & 575V SSW060480T2257ESZ SSW060255T2257ESZ SSW060205T5257ESZ
250
3600 447TS 460 & 575V SSW060604T2257ESZ SSW060312T2257ESZ SSW060255T5257ESZ
1800 447T 460 & 575V SSW060604T2257ESZ SSW060312T2257ESZ SSW060255T5257ESZ
1200 586/7T 460 & 575V SSW060604T2257ESZ SSW060312T2257ESZ SSW060255T5257ESZ
900 586/7T 460 & 575V SSW060604T2257ESZ SSW060312T2257ESZ SSW060255T5257ESZ
300
3600 586/7TS 460 & 575V SSW060820T2257ESZ SSW060365T2257ESZ SSW060312T5257ESZ
1800 586/7T 460 & 575V SSW060820T2257ESZ SSW060365T2257ESZ SSW060312T5257ESZ
1200 586/7T 460 & 575V SSW060820T2257ESZ SSW060365T2257ESZ SSW060312T5257ESZ
900 586/7T 460 & 575V SSW060820T2257ESZ SSW060365T2257ESZ SSW060312T5257ESZ
Notes: This chart is designed as a guide only. For specifi c sizing or sizing for larger motors please contact V.J. Pamensky Canada Inc.
101
Reference5.12
www.pamensky.com
Soft Starter Sizing GuideSSW 07
Motor SSW 07 Soft Starter Part Number
HP RPM Frame Voltage 230V 460V 575V
3
3600 W182T 208-230/460 & 575V SSW070017T5SZ
1800 W182T 208-230/460 & 575V SSW070017T5SZ
1200 213T 208-230/460 & 575V SSW070017T5SZ
900 215T 208-230/460 & 575V SSW070017T5SZ
5
3600 184T 208-230/460 & 575V SSW070017T5SZ SSW070017T5SZ SSW070017T5SZ
1800 184T 208-230/460 & 575V SSW070017T5SZ SSW070017T5SZ SSW070017T5SZ
1200 215T 208-230/460 & 575V SSW070017T5SZ SSW070017T5SZ SSW070017T5SZ
900 254T 208-230/460 & 575V SSW070017T5SZ SSW070017T5SZ SSW070017T5SZ
7.5
3600 213T 208-230/460 & 575V SSW070024T5SZ SSW070017T5SZ SSW070017T5SZ
1800 213T 208-230/460 & 575V SSW070024T5SZ SSW070017T5SZ SSW070017T5SZ
1200 254T 208-230/460 & 575V SSW070024T5SZ SSW070017T5SZ SSW070017T5SZ
900 256T 208-230/460 & 575V SSW070024T5SZ SSW070017T5SZ SSW070017T5SZ
10
3600 215T 208-230/460 & 575V SSW070030T5SZ SSW070017T5SZ SSW070017T5SZ
1800 215T 208-230/460 & 575V SSW070030T5SZ SSW070017T5SZ SSW070017T5SZ
1200 256T 208-230/460 & 575V SSW070030T5SZ SSW070017T5SZ SSW070017T5SZ
900 284T 208-230/460 & 575V SSW070030T5SZ SSW070017T5SZ SSW070017T5SZ
15
3600 254T 208-230/460 & 575V SSW070045T5SZ SSW070024T5SZ SSW070017T5SZ
1800 254T 208-230/460 & 575V SSW070045T5SZ SSW070024T5SZ SSW070017T5SZ
1200 284T 208-230/460 & 575V SSW070045T5SZ SSW070024T5SZ SSW070017T5SZ
900 286T 208-230/460 & 575V SSW070045T5SZ SSW070024T5SZ SSW070017T5SZ
20
3600 256T 208-230/460 & 575V SSW070061T5SZ SSW070030T5SZ SSW070024T5SZ
1800 256T 208-230/460 & 575V SSW070061T5SZ SSW070030T5SZ SSW070024T5SZ
1200 286T 208-230/460 & 575V SSW070061T5SZ SSW070030T5SZ SSW070024T5SZ
900 324T 208-230/460 & 575V SSW070061T5SZ SSW070030T5SZ SSW070024T5SZ
25
3600 284TS 208-230/460 & 575V SSW070085T5SZ SSW070045T5SZ SSW070030T5SZ
1800 284T 208-230/460 & 575V SSW070085T5SZ SSW070045T5SZ SSW070030T5SZ
1200 324T 208-230/460 & 575V SSW070085T5SZ SSW070045T5SZ SSW070030T5SZ
900 326T 208-230/460 & 575V SSW070085T5SZ SSW070045T5SZ SSW070030T5SZ
30
3600 286TS 208-230/460 & 575V SSW070085T5SZ SSW070045T5SZ SSW070030T5SZ
1800 286T 208-230/460 & 575V SSW070085T5SZ SSW070045T5SZ SSW070030T5SZ
1200 326T 208-230/460 & 575V SSW070085T5SZ SSW070045T5SZ SSW070030T5SZ
900 364/5T 208-230/460 & 575V SSW070085T5SZ SSW070045T5SZ SSW070030T5SZ
40
3600 324TS 208-230/460 & 575V SSW070130T5SZ SSW070061T5SZ SSW070045T5SZ
1800 324T 208-230/460 & 575V SSW070130T5SZ SSW070061T5SZ SSW070045T5SZ
1200 364/5T 208-230/460 & 575V SSW070130T5SZ SSW070061T5SZ SSW070045T5SZ
900 364/5T 208-230/460 & 575V SSW070130T5SZ SSW070061T5SZ SSW070045T5SZ
50
3600 326TS 208-230/460 & 575V SSW070130T5SZ SSW070061T5SZ SSW070061T5SZ
1800 326T 208-230/460 & 575V SSW070130T5SZ SSW070061T5SZ SSW070061T5SZ
1200 364/5T 208-230/460 & 575V SSW070130T5SZ SSW070061T5SZ SSW070061T5SZ
900 404/5T 208-230/460 & 575V SSW070130T5SZ SSW070061T5SZ SSW070061T5SZ
60
3600 364/5TS 208-230/460 & 575V SSW070171T5SZ SSW070085T5SZ SSW070061T5SZ
1800 364/5T 208-230/460 & 575V SSW070171T5SZ SSW070085T5SZ SSW070061T5SZ
1200 404/5T 208-230/460 & 575V SSW070171T5SZ SSW070085T5SZ SSW070061T5SZ
900 404/5T 208-230/460 & 575V SSW070171T5SZ SSW070085T5SZ SSW070061T5SZ
75
3600 364/5TS 208-230/460 & 575V SSW070200T5SZ SSW070130T5SZ SSW070085T5SZ
1800 364/5T 208-230/460 & 575V SSW070200T5SZ SSW070130T5SZ SSW070085T5SZ
1200 404/5T 208-230/460 & 575V SSW070200T5SZ SSW070130T5SZ SSW070085T5SZ
900 444/5T 208-230/460 & 575V SSW070200T5SZ SSW070130T5SZ SSW070085T5SZ
100
3600 404/5TS 208-230/460 & 575V SSW070255T5SH1Z SSW070130T5SZ SSW070130T5SZ
1800 404/5T 208-230/460 & 575V SSW070255T5SH1Z SSW070130T5SZ SSW070130T5SZ
1200 444/5T 208-230/460 & 575V SSW070255T5SH1Z SSW070130T5SZ SSW070130T5SZ
900 444/5T 208-230/460 & 575V SSW070255T5SH1Z SSW070130T5SZ SSW070130T5SZ
101
Reference 5.13
www.pamensky.com
Soft Starter Sizing GuideSSW 07
Motor SSW 07 Soft Starter Part Number
HP RPM Frame Voltage 230V 460V 575V
125
3600 444/5TS 460 & 575V SSW070312T5SH1Z SSW070171T5SZ SSW070130T5SZ
1800 444/5T 460 & 575V SSW070312T5SH1Z SSW070171T5SZ SSW070130T5SZ
1200 444/5T 460 & 575V SSW070312T5SH1Z SSW070171T5SZ SSW070130T5SZ
900 504/5T 460 & 575V SSW070312T5SH1Z SSW070171T5SZ SSW070130T5SZ
150
3600 445TS 460 & 575V SSW070365T5SH1Z SSW070200T5SZ SSW070171T5SZ
1800 445T 460 & 575V SSW070365T5SH1Z SSW070200T5SZ SSW070171T5SZ
1200 447T 460 & 575V SSW070412T5SH1Z SSW070200T5SZ SSW070171T5SZ
900 504/5T 460 & 575V SSW070412T5SH1Z SSW070200T5SZ SSW070171T5SZ
200
3600 447TS 460 & 575V SSW070255T5SH1Z SSW070200T5SZ
1800 447T 460 & 575V SSW070255T5SH1Z SSW070200T5SZ
1200 447T 460 & 575V SSW070255T5SH1Z SSW070200T5SZ
900 449T 460 & 575V SSW070255T5SH1Z SSW070200T5SZ
250
3600 447TS 460 & 575V SSW070312T5SH1Z SSW070255T5SH1Z
1800 447T 460 & 575V SSW070312T5SH1Z SSW070255T5SH1Z
1200 586/7T 460 & 575V SSW070312T5SH1Z SSW070255T5SH1Z
900 586/7T 460 & 575V SSW070312T5SH1Z SSW070255T5SH1Z
300
3600 586/7TS 460 & 575V SSW070365T5SH1Z SSW070312T5SH1Z
1800 586/7T 460 & 575V SSW070365T5SH1Z SSW070312T5SH1Z
1200 586/7T 460 & 575V SSW070365T5SH1Z SSW070312T5SH1Z
900 586/7T 460 & 575V SSW070365T5SH1Z SSW070312T5SH1Z
Notes: This chart is designed as a guide only. For specifi c sizing or sizing for larger motors please contact V.J. Pamensky Canada Inc.