Page 1: ARDS Implants Catalog

2@Im

Page 2: ARDS Implants Catalog

@Im

0 4 8 3

ISO13485

@Im

Page 3: ARDS Implants Catalog

@Im@Im

Company’s profileARDS was established by Dr. Uri Arny and deals with thedevelopment, manufacturing and marketing of dentalimplants.ARDS’s guiding philosophy has inspired the company todevelop a unique drilling technique which causes minimum damage to the bone and maximizes the initial stabilization of the implants in it.

ARDS retains a number of international patents regarding-A. The shape of the implant’s surface.B. A drilling technique which preserves bone.C. Unique implants designed for thin ridges.

ARDS’s aspiration for perfection is conveyed in the following ways-1. Shortening the healing phase -immediate implant after extraction.2. The system enables the use of implants also in problematic areas.3. Making the implant process simple to assign. (User friendly).

The main advantages of ARDS drilling and implant process:1. Reduces the amount of drilled bone.2. Unique design of the implant increases the bone-implant contact in the surgery phase(in comparison with other implants of the same diameter) thus stabilizes the implant and shortens the process of bone- implant integration.3. ARDS’s drilling method and the shape of it’s implant causes a compression of the spongyosal bone around the apical part of the implant during its insertion. Dispersing the forces along the entire implant and not only at its upper part as in common implants held at the cortical bone at the end of the implantation.4. The drilling method enables precise control over the placement and shape of the bore hole. This is made possible by the usage of leading pins which direct the drill at the suitable angle throughout the process and stabilize it also in thin ridges.

ARDS’s main office and marketing management are situated at Rishon-Le-Zion, Israel. All manufacturing and packingsupervised processes are done at the production plantsituated at the industrial park of Teffen, Israel.

2

Dr. Arny Uri, ECO

Page 4: ARDS Implants Catalog

ARDS also markets super structures and bone substitutes, thus expanding the variety of solutions dentists can offer their patients.

External SurfaceThe required durable stabilization of the implant in the bone needs oseointegration. In order to intensify theosseointegration two processes are required:The first is blasting theimplant surface with small parts of silica which is notattached to the titanium surface so it leaves it pure.The second stage is etching the surface with organic acids which create the final micro pores of the surface and at the same time constitute the first cleaning stage of the surface area.

Type of TitaniumARDS implants are composed of medical titanium alloy Ti-6 AL-4V which retains all the manufacturers’ regulations.

ManufacturingAll ARDS implants and reconstruction parts aremanufactured at the company’s production plant, situated at the industrial park of Teffen in the north part of Israel. The plant contains quality control system and regulations of the highest required level with the approvals of ISO 9001, ISO 13485 of European body, CE 0483, and Israeli AMAR.

3

Page 5: ARDS Implants Catalog

Excellent approval for ARDS Implants from technicallaboratories and NAMSA laboratory, U.S.A.

4

Testing results - ARDS Implants

Corrosion Biocompetabily

Testing of the surface area Testing fatigue

The test was performed by the Technion,Haifa - Test no. B/82454• The test examined the resistance of the material and its corrosion potential.• The test was performed by immersing the implant in diffrent chemicals, heating to 37˚ and submission to electrical currents.

Results:Complete stability of the ARDS Implant - Theimplants are stable and has no corrosionpotential.

The test was performed by NAMSAlaboratory in the United StatesThere were 3 tests done on laboratory mice• Toxicity test - toxic potential of the implant• Sensitivity test - sensitivity potential that could be caused by the implant• Irritation test - potential irritations of the implant.

Results:All three tests proved that the implantis biocompetabily

The test was performed by the Technion,Haifa - Test no. B/83703The test was performed by an electronicmicroscope (SEM), that is equipped with asystem analysis of chemical elements (EDS).The test was performed by injecting a wet metallicacid on the surface aera of the implant, and finalcleaning by an organic acid.

Results:No absorption of foreign materials on thesurface area, and the observed elementsstands up to the highest standards.

Results:The only cracks were in the abutment screwto the level of 580 neuton, much more thanrequired. In the assembly and the implantthere was NO damage at all.

The test was performed by the Technion,Haifa - Test no. B/83371The test was performed on 3.75mm implants, 13mm in length.The implants were assembled with angulatedabutments of 25 degrees.The implants were exposed to cyclic forces up to afraction of one part.Testing done in accordance with standardsof ISO 14801 and the FDA regulations.

Page 6: ARDS Implants Catalog

5

IntroductionAs the popularity of using implants in dental restorative procedure gains momentum, there is a need to find in-novative dental implant, which will effectively transfer the loads and provide a necessary stabilization into jaw-bone. This paper presents the development results of a novel implant with a Hybrid Dual Thread Screw as shown in Fig. 1. This approach allows obtaining a high reinforce-ment of the implant in the jawbone by a reduction of the drilling bone volume along with an additional gain of pri-mary surface contact relatively to classical implants.To prove the concept, analytical models and experiment tests were carried out during the development of an im-plant with Hybrid Dual Thread Screw (HDTS). The ana-lytical calculations are based on Finite Element Model, while the experiment tests were done on an artificial bone made of Fiberglass and Structural foam, which rep-resents the bone mechanical properties. These unique experimental tests have been chosen, since the clinical tests evaluations on animals are not efficient. The animal has different dental jaw structure and it requires a lot of time to get the results.

HDTS Implant DescriptionThe unique HDTS dental Implant, shown in Fig. 1, uses two different thread types, double thread thin grove at the implant interface area with the cortical bone and single thread thick groves at the cancellous. This unique design allows facilitating the transfer of occlusal forces to the greatest surface area of the bone-implant inter-face for favorable load distribution. Also it reduces the amount of bone removed by using a novel drilling pro-cedure.

Figure 1: Hybrid Dual Thread Screw (HDTS) Implant

Experimental MethodForce-displacement tests have been carried out on Clas-sical Cylindrical Implant and HDTS implant both have diameter of 4.5 mm and 13 mm in length. The implants have been inserted in an artificial bone specimen shown in Fig. 2, the cross section dimensions of this specimen are of a typical mandible as is shown in Fig. 3. An axial load was applied onto the implant head until failure was reached. During the static tests the force-displacement curves were recorded and axial stiffness has been calcu-lated.

Fig. 2: Artificial Bone Specimen

Fig. 3: Artificial Bone Specimen Cross Section (Dimensions in mm>)

Hybrid Dual Thread Screw Implant - Analytical and Experimental Research

Dr. Uri Arny, Ilan Weissberg M.Fc & Oved Gihon, Mechanical engineer.

Single TreadThick Grove

Double TreadThin Grove

ArtificialCortical

Implant

ArtificialCancellous

Page 7: ARDS Implants Catalog

6

Experimental ResultsThe experimental tests showed that the HDTS implant could carry higher axial load compared to classical cylin-der implants, as is shown in figure 4. It is also shown that HDTS implant has higher stiffness then the classical cylin-drical implant. The stiffness of the implants is compatible with measured axial stiffness of 180 Kg/mm published in the literature for Branemark (7 mm’) in trabecular bone. These results increase the reliability of the preformed experimental tests.

Analytical MethodFinite Element Model (FEM) of an implant installed in a standard jawbone cross section has been built using NASTRAN FEM software. The aim of this study was to evaluate the influence of HDTS implant versus classical cylindrical implants on the stress intensity and stress dis-tribution due to axial load. Two analytical models were built for the identical specimen types described above. The Implant stress distribution at the bone cross section was calculated.The FEM model of the dental implant bone system used 2-D Plate elements; the model is symmetrical since only axial (vertical) load was analyzed, as is shown in Fig. 5.

Analytical ResultsThe analytical calculations showed that the HDTS im-plant have favorable stress distribution over the clas-sical cylindrical implant. The maximal shear stress level at the cortical jawbone with HDTS implant is 15% to 25% lower compared with a classical cylindrical implant, this is shown in Fig 6, which plots the max

Fig. 4: Implant tests under compression axial load

Fig. 5: Analytical Model for HDTS Implant

shear stress distribution in the cortical bone under an axial load of 40 Kg for the both type of implants.

Discussion & ConclusionsThe experimental tests showed that HDTS implant achieved the highest vertical load capability compared with a classical cylindrical implant. The unique tests experiments method evaluates in this study provided short development time by using artificial bone speci-men. These experiments were done with a background of analytical calculations. The lower shear stress values at the cortical bone evaluate for the HDTS implant com-pared to with the classical cylindrical implants provides the advantage of the HDTS implant regarding on carry-ing higher loads and increasing life time of the HDTS im-plant. This phenomenon is mostly due to the innovative implant geometry and bone drilling method.

Fig. 6: The Max Cortical Shear Stress Distribution for the Two Implants Models @ 40 Kg Vertical Load

ReferencesLawrence B. Lum,A Biomechanical Rationale for the use of Short Implants. Journal of Oral Implantology Vol. XVII/No. Tow/1991 pp126-131Borchers L. Relchart P. “Three- dimensional stress dis-tribution around a dental implant at different stages of interface development”. J. Dent Res 1983 62(2):156-159Kitoh, M; Matsushita, Y.; Yamautue, S; Ikedda, H.; and Suetsugu, T. The Stress Distribution of Hydroxyapatite Implant Under Vertical Load by the Two-Dimensional Fi-nite Element Method. Journal of Implantol 14:65-71Dechow P.C. Naill G.A. Schwartz-Dabney C.L. and Ash-man R.B., “Elastic properties of the human supraorbital and mandibular bone”. Am J Phys Anthropol 90, pp 291-306. 1993.

Page 8: ARDS Implants Catalog

7

Packaging

Packaging contains:Implant, Healing cap, Leading pin, double-label to allow recording used implant on patient’s form.

All implants are sterilized and gamma-ray.

All implants are packed with mounling tool, no-touch delivery carrier.

All implants are double packed – the outer clean, the inner sterilized.

All super structure clean and ready to be used.

All implants comes with colour code improve their usability.

4.5mm4.2mm3.75mm3mm

Page 9: ARDS Implants Catalog

8

Implants

CodeLength

13mm

11.5mm

10mm

S37513

S37511

S37510

CodeLength

13mm

11.5mm

10mm

S42013

S42011

S42010

CodeLength

13mm

11.5mm

10mm

S45013

S45011

S45010

3mm

3.75mm

4.2mm

4.5mm

Length Code

13mm

11.5mm

10mm

N31300

N31100

N31000CodeLength

13mm

11.5mm

10mm

N31317

N31117

N31017

3mm

Page 10: ARDS Implants Catalog

9

Leading PinsLeading pin of titanium alloyMarked 3mm from tip, both sides comes with the implant disposable.

Code

S45013

CodeLength

10mm

11.5mm

13mm

LD0013

LD0014

LD0016

16mm 14.5mm 13mm

Healing screwSurgical screw of titanium alloy to cover all ARDS implants,3.75, 4.2, 4.5comes with every implant.

Page 11: ARDS Implants Catalog

10

5.5

mm

13

mm

10m

m

5

.5m

m

13m

m

10m

m

5.5m

m

13m

m

10m

m

13m

m

10

mm

5.5

mm

DR0010

Code

DR0020

Code

DR0028

Code

DR0036

Code

DR0040

Code

DR0042

Code

Marking

2mm

2.8mm

3.6mm

4mm

4.2mm

Drills

Marking

Marking2mm

2mm2.8mm

Marking

2mm2.8mm

Marking

3.6mm

2mm2.8mm

Marking

3.6mm4mm

3mm

3.75mm

4.2mm

4.5mm

Page 12: ARDS Implants Catalog

11

Prosthetic Components Healing Caps

HO3000

Code

HO3753

Code

HO3755

Code

HW3753

Code

HW3755

Code

Healing cap – widehight: 3mm

Healing cap – widehight: 5mm

Healing cap for 3mm ARDS implants

Healing cap - straighthight: 3mm

Healing cap - straighthight: 5mm

Page 13: ARDS Implants Catalog

12

Prosthetic ComponentsAbutments

A37515

Code

A37525

Code

A37530

Code

A37500

Code

A3753W

Code

A3750W

Code

A30000

Code

Straight abutmenthight: 0mm

Straight abutmenthight: 3mm

Straight abutment -Widehight: 0mm

Straight abutment -Widehight: 3mm

Abutment for 3mm ARDS implants

15deg. Abutment

25deg. Abutment

Page 14: ARDS Implants Catalog

13

Prosthetic ComponentsShoulder AbutmentsAbutment made of titanium alloy antirotational Available in 4 heights of neck: 1mm, 2mm ,3mm ,4mm

Fits 3.75, 4.2, 4.5 mm ARDS implantsIndicated specially for one stage and immediate loading technique.

AS3751

Code

AS3752

Code

AS3753

Code

AS3754

Code

AS375S

Code

Shoulder Abutmenthight: 1mm

Shoulder Abutmenthight: 2mm

Shoulder Abutmenthight: 3mm

Shoulder Abutmenthight: 4mm

Universal Plastic Sleevewith internal hex

Page 15: ARDS Implants Catalog

14

Prosthetic Components Ball Attachment Components

BA3751

Code

BA3752

Code

BA3753

Code

BA3000

Code

TITHOL

Code

SILATC

Code

Ball attachment with 1mm, 2mm and 3mm neck for 3.75mm, 4.2mm and 4.5mm ARDS Implants

Ball attachment for 3mm ARDS Implants

Ball Attachmenthight: 1mm

Ball Attachmenthight: 2mm

Ball Attachmenthight: 3mm

Silicon Cap Metal Cap

Page 16: ARDS Implants Catalog

15

Prosthetic ComponentsOverdenture Components

OD3751

Code

OD3752

Code

OD3753

Code

ODS002

Code

ODS001

Code

1mm overdenture intermediate component that connect between The implant and the plastic sleeve.

2mm overdenture intermediate component that connect between The implant and the plastic sleeve.

3mm overdenture intermediate component that connect between The implant and the plastic sleeve.

Plastic casting sleeve without internal hex for overdentureIntermediate components.

Screw for overdenture intermediate part.

Page 17: ARDS Implants Catalog

AN3000

Code

TR3750

Code

16

Prosthetic ComponentsAccessories

AN3750

Code

AOD375

Code

P3750W

Code

OD3000

Code

P3750M

Code

P3750S

Code

Laboratory analog for 3mm ARDS implants.

Laboratory analog to be used for overdenture, fits 3.75mm, 4.2mm,4.5mm implantdiameters.

Laboratory analog to be used along with transfer, fits 3.75mm, 4.2mm, 4.5mm implant diameters.

Transfer for impression to be used along with 3.75mm, 4.2mm, 4.5mm ARDS implants.

Plastic SleeveMulti

Plastic SleeveSingle

Plastic SleeveWide/Single

Plastic Sleevefor 3mmARDS Implants

Page 18: ARDS Implants Catalog

17

BOX001

Code

Tools

Surgical box

CodeLength

7mm

15mm

MT0001

MT0002

MT0008

Code

CodeLength

7mm

15mm

MT0003

MT0004

Ratchet for ARDS implants

Ratchet Driver for ARDS implants

Hand Driver for ARDS abutments and screws

Page 19: ARDS Implants Catalog

18

CodeLength

7mm

15mm

MT0005

MT0006

MT0009

Code

Ratchet Driver for ARDS abutments and screws

MT0007

Code

Ratchet Driver for ARDS overdentures

Implant Driver for hand piece

Page 20: ARDS Implants Catalog

19

Gen-OsMix of cancellous and cortical heterologous bone with collagen.Granulometry : 250 -1000µ (micron)

ApatosHeterologous cortical and cancellous bone without collagen.Granulometry - 600 - 1000µ (micron)

MP3Heterologous cortico-cancellous collagenated bone mix with 10% collagen gel type 1 and 3.Granulometry - 600 - 1000µ (micron)

Gel 40Collagen gel loaded with 60% bone mix of cancellous and corticalheterologous bone.Granulometry ≥ 300µ (micron)

SpecialTranslucent dried membrane,heterologous pericardium.Packeging : 20x20, Xfine

EvolutionDried heterologous pericardium membrane.Packaging : 20x20, 25x35Standard or fine

Bone Substitutes and Membranes

Collagenated fillers composition

Page 21: ARDS Implants Catalog

20

Post - Extractive Sockets Only if Defect WallsAre Preserved

Only if there isGraft Exposure Risk

In case of CoagulationProblems

Crestal Access Sinus Lift Gel with granules≤ 300 Micron

Granulometry250 - 1000

Lateral Access Sinus Lift Granulometry600 - 1000

Antrostomy Covering Granulometry250 - 1000

Two Wall Defects Granulometry250 - 1000

Standard Model Must be fixed withOsteosynthesis Screws

Intrabony Defects Small Defectswith < 30˚ Angle

Deep Defectsand Furcations

Regeneration Type Product 1 Product 2 Possible Alternatives

Page 22: ARDS Implants Catalog

21

Prosthetic OptionsFixed Removable Overdenture

Healing Caps Intermediate Parts

Casting Sleeves Customized Tray in place

Final RestorationFinal Casted Bar

Page 23: ARDS Implants Catalog

22

Prosthetic OptionsRemovable Overdenture

Healing Caps Intermediate Parts

Casting Sleeves Customized Tray in place

Final RestorationFinal Casted Bar with ball attachments

Page 24: ARDS Implants Catalog

2@Im

2@Im

23

Prosthetic OptionsFixed Removable Restorations

Prosthetic OptionsCemented Related Restorations

Straight Abutment 15˚ Abutment 25˚ Abutment Shoulder Abutment

Plastic Sleevefor single restoration

Plastic Sleevefor Multiple restoration

Wide Plastic Sleeve

Plastic Sleevefor 3mm implant

Plastic Sleevewith intermediate part

Abutmentfor 3mm implant

Page 25: ARDS Implants Catalog