air slide version 24 sept 03
DESCRIPTION
cement transport air slideTRANSCRIPT
-
Fuller Airslide Conveying TechnologyFluidized Gravity Conveying Systems
n Economical, energy-efficient
n High capacity, high performance
n Versatile and reliable
-
Fuller AirslideTM Operation Air-activated gravity conveyor
Fluidization of material on the Airslide media
Fluidization reduces the angle of repose causing flow.
Example: A material with a normal angle repose of45 with fluidization may flow like a liquid on a 5 to6 slope.
Fuller Airslide Manufacturing Standards Heavy-gauge steel sections with bent flanges
Airslide conveyors are shipped in standard sectionlengths of 12ft (3.65m)
Standard widths of fluidized area is 4 up to 34(100 to 850mm)
Bolted airtight flanges
Optional fabric media available to fit the application
There is no conveying length limitation to the Airslide conveyor based upon availability of headroom and proper slope.
Designed for dependability.Proven to perform.
Fluidized Material Chamber
Porous Membrane Fabric
Low-Pressure Air Chamber (.5-5.0 psi)
5
-
Airslide Loading & Unloading Systems
Railcar High-capacity loading and unloading systems
Trailer Dust-controlled loading and unloading systems
Large Diameter Silos Efficient filling and unloading systems
Uniform filling system
Fluidized silo bottom
Fuller Airlift and Airslide conveying systems convey alumina at a net rate of 750 mtph in a major Western United States facility.
F.L.Smidth Advantages Engineered system
Single-source responsibility
Global service / technology support
Reliable designs based upon experience
2
-
Airslide Conveyor Applications
Conveying: Quiet & Simple Point-to-Point Transfer
Positive flow regulation (low - high capacities)
Quiet operation
Low maintenance no rotating parts in contact
with materials being conveyed
Fully fluidized gentle conveying action Minimized wear from abrasion
Generally, materials passing through 35 mesh US Std. can be conveyed through a Fuller Airslide.
Proven Application Examples: Alumina
Barytes
Bentonite
Calcined Magnesite
Cement Raw and Finish Material
Clay
Fly Ash
Ground Ores
Phosphates
Precipitator Dust
Resins
Silica
Enlarged detail below
Controlled Discharge
From Silo
Typical Isolation and Flow ControlValve Arrangement
Drum Roller
3
-
Airslide ConveyingMultiple Inlet to Multiple Outlets
A
B
C
D
E
FG
HI
J
K
L MN
O
P
Q
L
A. Blank End PlateB. Air ConnectionC. Air Control ValveD. Positive Displacement BlowerE. FanF. Rotary Cut-Off ValveG. Inlet NeckH. Butterfly Flow GateI. Rotary Metering Flow Gate
J. Side Discharge ValveK. Observation PortL. TurnboxM. Discharge BoxN. Vent ConnectionO. Airslide Conveyor Swivel AssemblyP. Telescopic Loading SpoutQ. Fuller-Kinyon Pump
Flexibility No additional conveyors needed to
change directions
Single Power Source One blower or fan is sufficient for system
High Capacity / Long Distance Conveying volumes up to 1500 cubic meters and
conveying distances in the 100s of feet
4
-
Up-to-date addresses of worldwide subsidiaries and sales offices are available from our website.
USAF.L.Smidth Inc. 2040 Avenue CBethlehem, PA 18017Tel: +1-610-264-6011Fax: +1-610-264-6170Toll-free: +1-800-523-9482
09-2
003-
PT A
S
SIZE
TYPE
4
6
8
10
12
14
16
19
24
A
mm
100
150
200
250
300
350
400
480
600
NOMINAL CAPACITY
(1) cu.ft./hr.
720
1200
3060
4030
7620
12700
15000
21200
56000
B
(1) in.
1.25
1.25
1.25
1.25
1.25
1.25
1.25
1.50
2.25
C
(1) in.
7.87
7.87
11.81
11.81
15.75
19.69
19.69
22.05
23.62
D
(1) in.
2.95
2.95
2.95
2.95
2.95
2.95
2.95
2.95
3.94
WEIGHT
lb./ft.
13
15
20
22
26
30
32
38
46
HI-TOP DESIGN
kg./m
19
22
30
33
39
45
48
57
68
mm
75
75
75
75
75
75
75
75
100
mm
200
200
300
300
400
500
500
560
600
mm
32
32
32
32
32
32
32
38
57
cu.m/hr.
20
34
87
114
216
360
425
600
1586
Nominal capacity ratings are based upon loose poured bulk density of the material and proper application. (1) English dimensions andcapacities are nominal.
See chart below for dimensions.
Fuller AirslideConveying Media Options
Section Material Application
F Woven 5-Ply Polyester Standard up to 350F
FS Silicon-Treated Polyester Special for Static Dissipation
GAX 19 Woven Fiberglass High Temperature up to 850F
FN Needle Felt Non-Woven Standard Non-Silo BottomApplications
KN Needle Kevlar Fabric Standard Non-Silo BottomApplications up to 475F
K Woven Kevlar Fabric Standard Including Silo Bot-tom Applications up to 475F
Data in this brochure is intended for preliminary project planning only. Manufacturer reserves the rightto modify equipment details and/or specifications without notice.
www.flsmidth.comwww.fls-pt.com