1
work processing channel is lined with 0.5 to 1.0 in. of urethane and is equipped with a self-contained com- pound rinsing system. The system em- ploys a combination of the Raytech AVT-250 vibratory tub machine and the MS-75 automatic parts/media sep- arator. Circle 419 on the reader service card Crossflow Scrubber Tri-Mer Corp. Owosso, Mich. The Tri-Mer Crossflow Series l/25 is engineered to scrub virtually all in- organic compounds. Dual-stage, high- speed liquid recirculation produces in- tense contact between the contaminant and scrubbing liquid and produces ex- tremely low stack emissions (below 80 ppb), regardless of input loading. Three system configurations are avail- able in capacities of 50 through 100,000 cfm, 50 through 50,000 cfm, and 120,000 cfm. Crossflow scrubbers are supplied with control panels, which incorporate flow meters, pH controls, flow indicators, ORP, alarms and aux- iliaries. Circle 420 on the reader service card Air-Operated Double Diaphragm Pumps Versa-Math! Pump Co. Pittsburgh Versa-Matic Pump recently was granted UL (Underwriters Laboratory) listing on two of its l-in. V-Series. The UL listing for the V-Series l-in. alumi- num foot-mounted pumps and the V- Series l-in. stainless steel foot- mounted pumps, both fitted with Teflon elastomers, allows for their use in hazardous and flammable liquid transfer applications. In accordance with UL-79 Standards, these pumps should be used only in applications where inlet pressure does not exceed 50 psig and discharge pressure does not exceed 32 psig. Circle 421 on the reader service card Drain Valve Van Air Systems Inc. Lake City Pa. The model EDV-2002 Terminator, internally-piloted solenoid drain valve, automatically drains compressed air condensate from air dryers, receivers, separators, aftercoolers, and filters. For installation indoors or out, the EDV- 2002 is available in AC or DC volt- ages, with standard connection sizes of i/4 or i/2 in., and is rated for maximum working pressure of 300 psig. Circle 422 on the reader service card Air-Powered Double-Diaphragm Pump Yamada America Inc. E/gin, 111. A 3-in. air-powered double-dia- phragm pump with aluminum housing is now available from Yamada Amer- ica. Designed for handling viscous liq- uids, the Yamada NDP-80 Aluminum Pump features transfer rates as high as 214 gpm and can handle particles as large as 13i32 in. The pump is available with either Neoprene, Buna N, Hytral, EPDM, PTFE, or Viton diaphragms, can withstand liquid temperatures as high as 248”F, and incorporates a non- stalling air valve that never requires lubrication. Other standard features of the NDP-80 include leak-free flange connections, an integral air valve reset button, and corrosion resistant Ryton air valve components. Circle 423 on the reader service card Stainless Steel Heaters Watlow Electric Manufacturing Co. St Louis Watlow’s line of 316 stainless steel heaters are specifically designed to re- sist corrosion in deionized water and cleaning and corrosive liquid applica- tions. All wetted surfaces on the heat- ers are 316 stainless steel to resist cor- rosion, and passivated to remove free iron that might contaminate processes. The heaters are available in tubular screw plug, flange, and circulation de- signs. Watlow’s 3 16 stainless steel heaters are ideal for ultrasonic cleaning applications where 3 16 stainless steel 66 METAL FINISHING . DECEMBER 1996

Upload: vodat

Post on 01-Jan-2017

220 views

Category:

Documents


3 download

TRANSCRIPT

Page 1: Air-operated double diaphragm pumps

work processing channel is lined with 0.5 to 1.0 in. of urethane and is equipped with a self-contained com- pound rinsing system. The system em- ploys a combination of the Raytech AVT-250 vibratory tub machine and the MS-75 automatic parts/media sep- arator.

Circle 419 on the reader service card

Crossflow Scrubber Tri-Mer Corp. Owosso, Mich.

The Tri-Mer Crossflow Series l/25 is engineered to scrub virtually all in- organic compounds. Dual-stage, high- speed liquid recirculation produces in- tense contact between the contaminant and scrubbing liquid and produces ex- tremely low stack emissions (below 80 ppb), regardless of input loading. Three system configurations are avail- able in capacities of 50 through 100,000 cfm, 50 through 50,000 cfm, and 120,000 cfm. Crossflow scrubbers are supplied with control panels, which incorporate flow meters, pH controls, flow indicators, ORP, alarms and aux- iliaries.

Circle 420 on the reader service card

Air-Operated Double Diaphragm Pumps Versa-Math! Pump Co. Pittsburgh

Versa-Matic Pump recently was granted UL (Underwriters Laboratory) listing on two of its l-in. V-Series. The

UL listing for the V-Series l-in. alumi- num foot-mounted pumps and the V- Series l-in. stainless steel foot- mounted pumps, both fitted with Teflon elastomers, allows for their use in hazardous and flammable liquid transfer applications. In accordance with UL-79 Standards, these pumps should be used only in applications where inlet pressure does not exceed 50 psig and discharge pressure does not exceed 32 psig.

Circle 421 on the reader service card

Drain Valve Van Air Systems Inc. Lake City Pa.

The model EDV-2002 Terminator, internally-piloted solenoid drain valve, automatically drains compressed air condensate from air dryers, receivers, separators, aftercoolers, and filters. For installation indoors or out, the EDV- 2002 is available in AC or DC volt- ages, with standard connection sizes of i/4 or i/2 in., and is rated for maximum working pressure of 300 psig.

Circle 422 on the reader service card

Air-Powered Double-Diaphragm Pump Yamada America Inc. E/gin, 111.

A 3-in. air-powered double-dia- phragm pump with aluminum housing is now available from Yamada Amer- ica. Designed for handling viscous liq- uids, the Yamada NDP-80 Aluminum

Pump features transfer rates as high as 214 gpm and can handle particles as large as 13i32 in. The pump is available with either Neoprene, Buna N, Hytral, EPDM, PTFE, or Viton diaphragms, can withstand liquid temperatures as high as 248”F, and incorporates a non- stalling air valve that never requires lubrication. Other standard features of the NDP-80 include leak-free flange connections, an integral air valve reset button, and corrosion resistant Ryton air valve components.

Circle 423 on the reader service card

Stainless Steel Heaters Watlow Electric Manufacturing Co. St Louis

Watlow’s line of 316 stainless steel heaters are specifically designed to re- sist corrosion in deionized water and cleaning and corrosive liquid applica- tions. All wetted surfaces on the heat- ers are 316 stainless steel to resist cor- rosion, and passivated to remove free iron that might contaminate processes. The heaters are available in tubular screw plug, flange, and circulation de- signs. Watlow’s 3 16 stainless steel heaters are ideal for ultrasonic cleaning applications where 3 16 stainless steel

66 METAL FINISHING . DECEMBER 1996