agilent general purpose rf instruments -...

8
Agilent General Purpose RF Instruments

Upload: duongdan

Post on 14-Feb-2018

234 views

Category:

Documents


5 download

TRANSCRIPT

Page 1: Agilent General Purpose RF Instruments - Microsoftprokcssmedia.blob.core.windows.net/sys-master-images/h0d/h39/... · The RF training kit offers unique ... Agilent N9320B RF Spectrum

AgilentGeneral PurposeRF Instruments

Page 2: Agilent General Purpose RF Instruments - Microsoftprokcssmedia.blob.core.windows.net/sys-master-images/h0d/h39/... · The RF training kit offers unique ... Agilent N9320B RF Spectrum

Agilent N9310A RF Signal Generator

www.agilent.com/find/n9310a

Built to Perform, Price to Compete

Professional Performance:

Features• Supports FDD and TDD mode in

frame structure type 1

• Supports 1.4 MHz, 1.6 MHz, 3 MHz,

3.2 MHz, 5 MHz, 10 MHz, 15 MHz, and 20 MHz bandwidth

• Cyclic prefix (normal or extended)

• Modulation type (QPSK, 16QAM, or 64QAM)

• Downlink synchronization signals (P-SCH , S-SCH)

• Supports partial resource block mode when the total number of resource blocks is odd

• Downlink reference signal

• Uplink reference signal (Zadoff-Chu sequence)

• Downlink EVM and uplink EVM measurement

Value

• RF Output frequency Range: 9 kHz to 3 GHz• Low Frequency Output: 20 Hz to 80 kHz• Level: -127 dBm to +13 dBm (settable to +20 dBm)• Sweep: Frequency/Amplitude/List• SSB Phase Noise: -95 dBc/Hz (20 kHz offset)• Switch Time: < 10 ms• Modulation: AM,FM,ΦM, pulse modulation• IQ Modulator: 40 MHz baseband bandwidth

Options• N9310A-001: IQ modulator• N9310A-1PA: 30 dB power attenuator

Design for Usability:• A clear, bright 6.5’ TFT color screen with associated, easy-to-read soft keys help users quickly set• Up to 11 languages user interface shorten the learning curve of users all over the world• USB ports for fast remote control and easy configuration transfer• Compact size and light weight, save your space on a crowded bench

and higher data efficiencies for LTE drives greater design and verifica-

tion needs.

• Validates to the market that your product will effectively meet the need for the latest LTE standard

• Saves you time and money by mak-ing verification a part of the design process and allows testing existing models to the new standard

• Verify both developed hardware and designs by using ADS and connected solutions. This enables you to drive efficiency with co-development and ensuring proper integration.

Optimizing your lab’s flexibilityThe RF training kit offers unique flexibility. Not only can students simulate the typical Tx and Rx paths, but also the main components can be used separately for characterization experiments.

Straightforward and engaging for your studentsAgilent’s industry leading RF instruments and the easy–to-use RF training kit helps you to create a high quality educational lab that enables your students to gain an intuitive understanding of the RF world.

Extended value from a single suiteBesides helping you to generate effective labs for your students, Agilent’s basic RF signal generator andspectrum analyzers have sufficient performance for many basic research projects.

RF training solution Engage your students the moment they touch the real RF world

RF Training Kit: TX board, RX board

2

Page 3: Agilent General Purpose RF Instruments - Microsoftprokcssmedia.blob.core.windows.net/sys-master-images/h0d/h39/... · The RF training kit offers unique ... Agilent N9320B RF Spectrum

Agilent N9320B RF Spectrum AnalyzerBest-in-class performance, practical value

Exceptional Usability

Element W2368 provides the full RF-PHY verification for the latest 3GPP long term evolution (LTE) cellular standard. LTE encompasses high-speed data, high-capacity voice and multi-media broadcast services. This wireless library provides the “golden standard” signal processing models and preconfigured simulation for Agilent’s Advanced Design System (ADS) EDA software to verify the RF components of the physi-cal layer for compliance against the 3GPP LTE standards.

Features• Supports FDD and TDD mode in

frame structure type 1

• Supports 1.4 MHz, 1.6 MHz, 3 MHz,

3.2 MHz, 5 MHz, 10 MHz, 15 MHz, and 20 MHz bandwidth

• Cyclic prefix (normal or extended)

• Modulation type (QPSK, 16QAM, or 64QAM)

• Downlink synchronization signals (P-SCH , S-SCH)

• Supports partial resource block mode when the total number of resource blocks is odd

• Downlink reference signal

• Uplink reference signal (Zadoff-Chu sequence)

• Downlink EVM and uplink EVM measurement

Easy to use RF analysis tool• One-button auto-tune quickly centers and reads out frequency and amplitude of the highest peak• Display 4 traces with independent detectors simultaneous• 12 markers with marker table and peak table• 11 languages user interface

Cost-effective tool for automated test projects• LAN, USB and GPIB connectivity• SCPI remote command set complies with IEEE488.2• Dedicate NI Labview driver• Remote language compatibility with Agilent ESA series spectrum analyzer

Best-in-Class Performance Superior performance• ±1.5 dB overall amplitude accuracy (typical ±0.5 dB)• Down to -148 dBm display average noise level (with 10 Hz RBW)• 10 Hz to 1 MHz RBW in 1-3-10 steps• -88 dBc/Hz at 10 kHz offset

Powerful Features• One button power suite including channel power, adjacent channel power, inter-modulation, spectrum emission mask and occupied bandwidth• AM/FM modulation analysis, tune & listen • Able to analysis ASK/FSK modulated signal, which are most commonly used in consumer electronics• CISPR EMI filters (-6 dB): 200 Hz, 9 kHz, 120 kHz and 1 MHz• Support USB memories for data logging and transfer• 3 GHz tracking generator for transmission test

P rofess iona l P erfo rm ance:

Key Options• N9320B-PA3: 3 GHz pre-amplifier • N9320B-TG3: 3 GHz tracking generator• N9320B-AMA: AM/FM demodulation metrics • N9320B-DAM: ASK/FSK demodulation metrics• N9320B-EMF: EMI filter • N9320B-G01: GPIB interface• N9320B-TR1: RF training kit • N9320B-1HB: Handle and bumper

www.agilent.com/find/n9320b

N9320B spectrum analyzer Minimize your cost Maximize your productivity

3

Page 4: Agilent General Purpose RF Instruments - Microsoftprokcssmedia.blob.core.windows.net/sys-master-images/h0d/h39/... · The RF training kit offers unique ... Agilent N9320B RF Spectrum

Agilent N1996A Portable Spectrum Analyzer

www.agilent.com/find/n1996a

Choice for General Spectrum Analysis up to 6 GHz

Professional Performance:• Frequency Range: 100 kHz to 3GHz/6GHz• Resolution Bandwidth: 10 Hz to 5 MHz• Display Average Noise Level: -156 dBm/Hz with Pre-amplifier on• TOI: +18 dBm (typical)• 1 dB compression: +13 dBm (nominal)• Phase Noise: -85 dBc/Hz (10 kHz offset)• Overall Amplitude Accuracy: + 0.5 dB (95% confidence)

Spectrogram

Stimulus response

Options

Features and Values:• Stimulus Response Measurement: with internal bridge and integrated software function, easy to measure S11, S21 and Distance to Fault• Idea portable Spectrum Analyzer for both bench and field operation: 8.5 kg weight with battery• Spectrogram for long time spectrum monitoring• Remote control through LAN: easiest to configure and stable connectivity• Auto Tune, Auto Scale and Auto Range: most convenient way to configure• Battery operatable

• N1996A-503: 100 kHz to 3 GHz Spectrum Analysis• N1996A-506: 100 kHz to 6 GHz Spectrum Analysis• N8995A-SR3: Stimulus-response suite, 3 GHz• N8995A-SR6: Stimulus-response suite, 6 GHz• N1996A-SRK: Stimulus response calibration kit• N1996A-AFM: AM/FM Tune and Listen• N8996A-1FP: AM/FM Demodulation Analysis• N1996A-271: Spectrogram measurement suite• N1996A-BAT: Battery pack, 2 pieces• N1996A-BCG: External battery charger

Battery pack

4

Page 5: Agilent General Purpose RF Instruments - Microsoftprokcssmedia.blob.core.windows.net/sys-master-images/h0d/h39/... · The RF training kit offers unique ... Agilent N9320B RF Spectrum

Agilent N9330B Cable and Antenna TesterFast test speed and good usability at a competitive price

Optimized designed for Usability • Battery with 4 hours operating time• 6.5’’ TFT screen with bright display for use indoors and outdoors• Rugged design for installation and maintenance measurement• 11 languages user interface

Increased productivity• Modern USB connectivity for unlimited external storage and remote control• Fast test speed to improve test efficiency• Pass/fail test with beep on/off

Fast measurement speed with best performance in class• Able to measure return loss, SWR, one port cable loss and distance to fault• Measurement Ranges: Return Loss: 0 to 60 dB SWR: 0 to 65 Cable Loss: 0 to 30 dB• Corrected directivity 38 dB with electrical calibrator 42 dB with mechanical calibrator• Max sweep points: 521• Typical 1.6 second @ full span, 521 data points

N9330B Options• N9330B-201: Precision mechanical short/open/50ohm load DC-4GHz N M• N9330B-202: Precision mechanical short/open/50ohm load DC-4GHz 7/16 DIN M• N9330B-203: Electronic Calibrator

• N9330B-301: Phase stable extension cable 1.5m Nm to N F

• N9330B-302: Phase stable extension cable 1.5m Nm to 7/16 DIN F

• N9330B-303: NM to 7/16 DIN F Adaptor

• N9330B-304: Extended cable1.5m N (male) – 1N(male)

• N9330B-BAT: Spare Battery Pack

www.agilent.com/find/n9330b

Tower

LightningDamage

Loose connectors

Pinched cable

Test port Cable

Signal Transmission

5

Page 6: Agilent General Purpose RF Instruments - Microsoftprokcssmedia.blob.core.windows.net/sys-master-images/h0d/h39/... · The RF training kit offers unique ... Agilent N9320B RF Spectrum

Agilent N9340B Handheld Spectrum Analyzer

www.agilent.com/find/n9340b

6

Built to Perform, Price to Compete

Usability designed for field testing• 6.5’’ TFT screenwith bright display for use indoors and outdoors• Back-lit keys for night use• Battery with 4 hours operating time, ruggedized design for installation and maintenance measurement

Increased productivitywithmodernconnectivity for remote control anddata transfer• USB, LAN and free PC software for remote control and data transfer, 11-language user interface

Options

More powerful features for field applications• Comprehensive interference analysis capability with spectrogram, to capture, logging and analysis time deviated or transient signal.• Spectrum emission mask for out-of-channel emission measurement• USB power sensor support• Field strength measurement to measure electric field strength and power flux density• Measurement of occupied bandwidth and channel power• AM/FM, ASK/FSK modulation analysis (optional)• Dedicate low frequency channel for high sensitivity test from 3 kHz to 12 MHz.

Achieve more complete understanding of spectrum, improve networks quality• Best sensitivity: DANL –144 dBm (with preamp)• Fastest sweep time: 10 ms min (None-zero span)• Narrowest resolution bandwidths: 30 Hz–1 MHz in 1-3-10 steps

INN

OVA

TIO

NS

Agilent MXG —Signal Generation

TechnologyReaches New

Heights

Innovations

T

Exceptional Usability

Superior Performance

introduced in September 2006 and its technical contributions have prompted signifi cant interest and curiosity

The Agilent MXG has been a huge success, due in part to the technical breakthroughs that made it possible. How were these breakthroughs achieved? What were the enabling technologies and processes that enabled these breakthroughs? How can

• N9340B-PA3: 3 GHz preamplifier• N9340B-TG3: 3 GHz tracking generator• N9340B-INM: Interference monitoring• N9340B-AMA: AM/FM modulation analysis• N9340B-DMA: ASK/FSK modulation analysis• N9340B-XDM: xDSL Measurement• N9340B-IBC: IBOC Measurement

Page 7: Agilent General Purpose RF Instruments - Microsoftprokcssmedia.blob.core.windows.net/sys-master-images/h0d/h39/... · The RF training kit offers unique ... Agilent N9320B RF Spectrum

Agilent N9311X RF and Microwave Accessory Kit

Exceptional Usability Best-in-Class Performance

P rofess iona l P erfo rm ance:

www.agilent.com/find/n9311x

7

Antenna Frequencyrange

Antenna gain Weight Dimension

N9311x-500 70 to 1000 MHz N/A

N/A

65 g 113.5 cm (full length), 19.5 cm (retracted), 10 stages

N9311x-501 700 to 2500 MHz 70 g 210 x 20 mm

N9311x-504

N9311x-501Antenna

700 MHz-4 GHz 4 dBi 270 g 340 x200 x 25 mm

N9311x-508 680 MHz-8 GHz 5 dBi 250 g 340 x 200 x 25 mm

N9311x-518 680 MHz-18 GHz 5 dBi 250 g 340 x 200 x 25 mm

Other information

180 degrees tilt angle adjustable, telescopic whip antenna

Logarithmic-periodic

Omni-directional

Logarithmic-periodic

Logarithmic-periodic

Bandpass FilterBandpass filter 3 dB Passband Rejection Insertion loss VSWR

N9311X-550 814 to 850 MHz ≥36 dBc @ 740 MHz≥36 dBc @ 915 MHz ≤0.5 dB ≤1.5

N9311X-551

N9311X-551

880 to 915 MHz ≥35 dBc @ 862 MHz≥35 dBc @ 932 MHz ≤1 dB ≤1.5

N9311X-552 1707.5 to 1787.5 MHz ≥35 dBc @ 1550 MHz≥35 dBc @ 1925 MHz

≤0.4 dB ≤1.5

N9311X-553 1845 to 1915 MHz ≥35 dBc @ 1770 MHz≥35 dBc @ 1986 MHz ≤0.6 dB ≤1.5

N9311X-554 1910 to 1990 MHz ≥35 dBc @ 1825 MHz≥35 dBc @ 2070 MHz ≤0.6 dB ≤1.5

AdapterN9311X-540N9311X-541 N9311X-543 N9311X-544N9311X-545 N9311X-546

Type-N(m) to BNC(f), DC to

2 GHz

Type-N(m) to SMA(f),

DC to 12.4 GHz

Type-N(f) to BNC(m), DC

to 4 GHz

Type-N(f) to 7/16 DIN(m), DC to 7.5 GHz

Type-N(f) to SMA(m), DC to 12.4 GHz

Type-N(f) to Type-N(f), DC

to 18 GHz

N9311X-542Type-N(f)

to 7/16 DIN(f), DC to 7.5 GHz

CableN9311X-580

1.5 m, Type-N(m) to type-N(m), DC to 18 GHz

N9311X-5813.0 m, Type-N(m) to type-N(m), DC to 18 GHz

N9311X-5821.5 m, Type-SMA(m) to type-SMA(m), DC to 8 GHz

N9311X-5831.5 m, Type-BNC(m) to type-BNC(m), DC to 1 GHz

Attenuator

N9311X-560 40 dB N (m) to N (f)

N9311X-561 40 dB N (m) to N (f)

N9311X-562 40 dB N (m) to N (f)

DC – 4.0 GHz: 1.154.0 – 8.5 GHz: 1.2DC – 4.0 GHz: 1.24.0 – 8.5 GHz: 1.3

DC – 4.0 GHz: 1.24.0 – 8.5 GHz: 1.3

10 watts average 67.3 mm (2.65 inch) 0.085 kg/3 oz

50 watts average 111.76 mm (4.37 inch) 0.28 kg/10 oz

100 watts average 112.01 mm (4.41 inch) 1.5 kg/3.3 lb

Attenuator Attenuation Port VSWR Power rating Length Weight

Page 8: Agilent General Purpose RF Instruments - Microsoftprokcssmedia.blob.core.windows.net/sys-master-images/h0d/h39/... · The RF training kit offers unique ... Agilent N9320B RF Spectrum

Remove all doubtOur repair and calibration serviceswill get your equipment back toyou, performing like new, whenpromised. You will get full value outof your Agilent equipment through-out its lifetime. Your equipmentwill be serviced by Agilent-trainedtechnicians using the latest factorycalibration procedures, automatedrepairdiagnosticsandgenuineparts.Youwill always have the utmost confidencein your measurements. For informationregarding self maintenance of thisproduct, please contact your Agilentoffice.

Agilentoffersawide rangeofadditionalexpert test and measurement servicesfor your equipment, including initialstart-up assistance, onsite educationand training, as well as design, systemintegration, and project management.

For more information on repair andcalibration services, go to:www.agilent.com/find/removealldoubt

Agilent Email Updates

www.agilent.com/find/emailupdatesGet the latest information on the products and applications you select.

www.lxistandard.orgLXI is the LAN-based successor to GPIB, providing faster, more efficient connectivity. Agilent is a founding member of the LXI consortium.

Agilent Channel Partners

www.agilent.com/find/channelpartnersGet the best of both worlds: Agilent’s measurement expertise and product breadth, combined with channel partner convenience.

For more information on Agilent Technologies’ products, applications or services, please contact your local Agilent office. The complete list is available at:www.agilent.com/find/contactus

AmericasCanada (877) 894 4414 Latin America 305 269 7500United States (800) 829 4444

Asia PacificAustralia 1 800 629 485China 800 810 0189Hong Kong 800 938 693India 1 800 112 929Japan 0120 (421) 345Korea 080 769 0800Malaysia 1 800 888 848Singapore 1 800 375 8100Taiwan 0800 047 866Thailand 1 800 226 008

Europe & Middle EastAustria 43 (0) 1 360 277 1571Belgium 32 (0) 2 404 93 40 Denmark 45 70 13 15 15Finland 358 (0) 10 855 2100France 0825 010 700*

*0.125 €/minuteGermany 49 (0) 7031 464 6333 Ireland 1890 924 204Israel 972-3-9288-504/544Italy 39 02 92 60 8484Netherlands 31 (0) 20 547 2111Spain 34 (91) 631 3300Sweden 0200-88 22 55Switzerland 0800 80 53 53United Kingdom 44 (0) 118 9276201Other European Countries: www.agilent.com/find/contactusRevised: October 1, 2009

Product specifications and descriptions in this document subject to change without notice.

© Agilent Technologies, Inc. 2009Printed in USA, February 10, 20105990-5212EN

www.agilent.com