Agilent GC/MS Portfolio

Smallest footprint, single GC column

Power of MRM

Industry leading GC/MS System

5975C with 7890GC

7000A GC/MS/MS

5975VL with 6850GC

Page 2: Agilent GC 7000

32nd ISCCRiva del GardaGC/MS Users Meeting

ISCC User Meeting

May, 2008Page 2

Agilent 7000A GC/MS/MS

Platform2.5 cm/ 1 inches

7000A Width36 cm/14 inches

5975: 31 cm/12 inches

Page 3: Agilent GC 7000

32nd ISCCRiva del GardaGC/MS Users Meeting

ISCC User Meeting

May, 2008Page 3

GC/MS Triple Quad (QQQ)

DetectorQuad 1Mass

Analysis

Collision Gas (Ar, N2, He)

Quad 2 Collision

Cell

Ion Source•Ionize

Quad 3Mass

Analysis

Carrier Gas (He, H2 )

Page 4: Agilent GC 7000

32nd ISCCRiva del GardaGC/MS Users Meeting

ISCC User Meeting

May, 2008Page 4

GC/MS Triple Quad (QQQ)

DetectorQuad 1Mass

Analysis

Collision Gas (Ar, N2, He)

Quad 2 Collision

Cell

Ion Source•Ionize

Quad 3Mass

Analysis

Carrier Gas (He, H2 )

Mean Free Path

Long LongShort

Page 5: Agilent GC 7000

32nd ISCCRiva del GardaGC/MS Users Meeting

ISCC User Meeting

May, 2008Page 5

GC/MS Triple Quad (QQQ)

DetectorQuad 1Mass

Analysis

Collision Gas (Ar, N2, He)

Quad 2 Collision

Cell

Ion Source•Ionize

Quad 3Mass

Analysis

Carrier Gas (He, H2 )

Q1 Post-filter

Q2 Pre-filter

Page 6: Agilent GC 7000

32nd ISCCRiva del GardaGC/MS Users Meeting

ISCC User Meeting

May, 2008Page 6

Agilent 7000 GC/MS/MS (QHQ)

DetectorQuad 1

Collision Gas (N2 )

Hexapole Collision

Cell

Ion Source•Ionize Quad 2

The hexapole field has excellent transmission efficiency for precursor and product ions

Q1 Post-filter

Q2 Pre-filter

Page 7: Agilent GC 7000

32nd ISCCRiva del GardaGC/MS Users Meeting

ISCC User Meeting

May, 2008Page 7

What is MRM MS/MS?Multiple Reaction Monitoring

Product 3

Product 2

EI: many ions from the source

Product 1

EI-MS/MS

Q1 SIM isolate precursor before CID

CID + Q2 SIM

Page 8: Agilent GC 7000

32nd ISCCRiva del GardaGC/MS Users Meeting

ISCC User Meeting

May, 2008Page 8

Why MS/MS?Greater Selectivity Than SIM

PrecursorIon

Product 1Product 3

Product 2

EI-SIMselectivity proportional to

spectral resolutionno selectivity against ions

with same m/z

EI-MS/MSPrecursor selectivity same as SIM

High probability that at least one product ion will be a unique dissociation product

of the precursor BUT not the interferenceinterference

analyte

interference

The precursor ion should NOT be used for ion ratios or quantitation since the interferences will

be the same as the SIM ion

unit mass resolution

Page 9: Agilent GC 7000

32nd ISCCRiva del GardaGC/MS Users Meeting

ISCC User Meeting

May, 2008Page 9

Why MS/MS?Lower detection limits by reducing noise

EI: many ions from the source

Q1 SIM isolate precursor before CID

chemical noise eliminated

Product ion signal often decreases, but the percentage decrease in noise is much larger for real samples; S/N and detection limits improve

Product 1Product 3

Product 2

CID + Q2 SIM

Product ion measured against zero chemical noise

Page 10: Agilent GC 7000

32nd ISCCRiva del GardaGC/MS Users Meeting

ISCC User Meeting

May, 2008Page 10

Why a GC/MS/MS System?

Allows for the selective quantitation of target compounds in high chemical background samples

Better S/N in complex matrices than can be achieved by single quadrupole scan or SIM approaches.

Newer regulations in some markets specify analytical power commensurate with GC/MS/MS

Page 11: Agilent GC 7000

32nd ISCCRiva del GardaGC/MS Users Meeting

ISCC User Meeting

May, 2008Page 11

Why GC/MS/MS? A Picture Is Worth a Thousand Words

GC/MS/MS QQQ MRM

GC/MS Single Quad SIM

EI 100fg HCB in “DIRTY” Matrix

S/N: 116:1 RMS

100 fg HCB

MS SIM

MS/MS MRM

A chromatographer’s dream: single peak on flat baseline

Page 12: Agilent GC 7000

32nd ISCCRiva del GardaGC/MS Users Meeting

ISCC User Meeting

May, 2008Page 12

Why GC/MS/MS? A Picture Is Worth a Thousand Words

GC/MS/MS QQQ MRM

GC/MS Single Quad SIM

EI 100fg HCB in “DIRTY” Matrix

S/N: 116:1 RMS

100 fg HCB

MS SIM

MS/MS MRM

A chromatographer’s dream: single peak on flat baseline