Agilent 5977 MSD

Overview

New GC/MSD Introduction

January 2013

January 15, 2013 1

New Agilent 5977 Series GC/MSD

January 15, 2013 2

The 5977 is the new Agilent GC/MSD platform and replaces the

5975C and 5975E systems

• Improves performance with high sensitivity Extractor Ion

Source

• MassHunter GC/MS Acquisition

• MassHunter and MSD ChemStation data analysis

• Integration of new Agilent Vacuum Pumps brings intelligent

operation

• Direct Communication between 7890B and 5977A for more

productivity

New Agilent 5977 Series GC/MSD

What is the same as 5975?

January 15, 2013 3

Quality

Reliability

Proven core technology since 5973/5975

• Inert Ion Source

• Heatable Gold Quartz Quadrupole

• Triple Axis Detector

• High Energy Diode

• Triple Channel EM Detector

• Productivity Software

(MSD ChemStation Data Analysis)

New Agilent 5977 Series GC/MSD

January 15, 2013 4

What is new with 5977?

Better Performance

• High Sensitive Extractor Ion Source

• Improved Agilent Vacuum Pump

More Productivity

• Direct Communication 7890B5977A

• Protect system

• Vent the system faster

• Power save (Sleep/Wake)

• MassHunter Software

• Data Acquisition (Method/Sequence)

• Data Analysis

New Extractor Ion Source for 5977

Page 5

Why the Extractor EI Source?

Increase in ion count

True increase in sensitivity

Better trace level precision

Lower IDL and MDL

Proven sensitivity increase demonstrated with

over 1500 7000 Series GC/TQ!

January 15, 2013

Comparison between Inert Ion Source and

Extractor Ion Source

Page 6

Repeller

(Push)

Drawout Plate

Ion Focus Lens

Entrance Lens

Ionization area

Ions

Inert Ion Source

Extractor Lens

(Pull)

Extractor Source

More ions to

Mass Filter

Mass Filter

January 15, 2013

How Extractor Ion source with “Etune” be seen in

the Chromatogram?

January 15, 2013 7

Blue – Extractor 40ppb solution (SVOC)

Red – Standard 40ppb solution (SVOC)

More improvements on 5977’s Extractor Ion Source:

Improved Thermal Profile

Page 8

Why is this important? Better performance of high boilers

i.e. PAH even at lower concentration!

10 Injections 80 min analysis

Good repeatability of

PAH even at the trace

level (5ppb)!!

Improvement for better Mass

Spectrometer of Gas Chromatograph

January 15, 2013

Sensitivity Specifications of the 5977

January 15, 2013 9

Full Scan EI Specification: S/N - Signal-to-Noise

The 5977 in scan mode has some background noise even if only OFN standard is injected, therefore the traditional Signal-to-Noise (S/N) is used as specification.

Agilent’s 5977 has the highest S/N (1500:1) with Extractor Ion Source among the SQ system. (1pg OFN)

SIM Specification: IDL - Instrument Detection Limit

Agilent 5977A uses this sensitivity specification for detection

techniques where no or little noise is generated, such as when OFN standard is injected. IDL is a new specification for SIM, but have been used with MS/MS for over a year.

5977A GC/MSD IDL Specification

IDL is a statistically derived value from the precision (%RSD) of 8

consecutive, splitless injections of 100fg OFN at 99 % confidence

level. The more precise instruments (lower %RSD) will generate lower

IDLs.

The Agilent 7890B/5977A with an ALS or CTC autosampler has the

following specifications:

January 15, 2013 10

Ion Source type High Vacuum pump type IDL of OFN by 8 replicates of ALS*

Extractor Source Turbo Pump 10fg

Inert Source

Turbo Pump 24fg

Diffusion Pump 30fg

*Systems without an Autosampler will have only S/N specification.

These are installation specification, performed on customer site, immediately

after installation and carry a lot more value than a reference specs.

Why IDL specification is useful for the 5977 in SIM?

Influence of Noise in S/N specs

• In SIM (or MS/MS) when the Noise is too low, such as during acquisition of an OFN standard, S/N results may not give the best characterization

• If the noise level is insignificant - varies a lot and too low- the derived value from it (S/N) also becomes insignificant

Value of IDL

• IDL is derived from reproducibility/precision results, the same metrics most users utilize every day in their work. The IDL statistical process is the same used for Method Detection Limit calculations, and the %RSD values are tools to monitor analytical performance

• IDL characterizes the whole system – AS, GC, MS- giving confidence in overall reliability. It is the results of 8 consecutive injections, unlike S/N in a single shut, which can be influenced by many parameters/conditions

January 15, 2013 11

The Influence of the low Noise on S/N values Same Data File, RMS, 5 Second Noise Region

Noise region: 5.66min - 5.74 min

S/N: 3335

Noise region: 5.65min - 5.73 min

S/N: 10785

A 0.01 min. shift in the noise region resulted a 6000 higher S/N value.

When the noise is insignificant (low), the derived S/N value is also insignificant!

Noise region:

5.65min-5.73 min

Noise region:

5.66min-5.74 min

S/N S/N

January 15, 2013 12

Better HW Features: Agilent Turbo Pump (V304)

Page 13

Agilent Quality Standard

TwisTorr 304 FS

Innovation for:

•Higher pumping performance

• especially for He and H2

•High reliability

• lower cost of operation

January 15, 2013

Press release : http://www.agilent.com/about/newsroom/presrel/2012/19dec-ca12077.html

Better HW Features: Agilent Rough Pumps

Page 14

New DS42i New IDP-3c

High performance

Energy saving design “Inverter” mode not active with diff pump

High performance

Oil-free scroll pump

NH3 CI compatible

with Agilent Quality Standards

January 15, 2013

Better HW Features: Power consumption saving of

MSD by Inverter Pump (DS42i)

15

0

100

200

300

400

Operation mode Sleep Mode

320W

190W

What this means to the

laboratory cost of ownership?

January 15, 2013

Example of Cost simulation of saving power with

Agilent 7890B/5977A at Environmental Lab

Assumptions

• GC/MSD cycle time: 40 minutes (30min for data acq./10 min for cool down & prep)

• Sample: 30 samples/day

• Working day: 5 days/week, no operating on Sat/Sun

GC/MSD wake time = 40 min/sample * 30 samples * 5 days/week

= 6,000 min/week = 100 hours/week

= 32 kWh

GC/MSD sleep time = 168 hours/week – 100 hours/week = 68 hours/week

= 13 kWh

Total Power usage (1 week) = 45 kWh (with Sleep mode)

Total Power Usage (1 week) = 54 kWh (without Sleep mode

Weekly MS Power saving per instrument = 9kWh (17%)

January 15, 2013 16

3 ways to go to Sleep mode

January 15, 2013 17

From the Sequence Keyword

From the menu item of

MassHunter

From the 7890B Keypad

Key features of “Direct Communication” between

7890B and 5977A

Page 18

Sleep/Wake mode

• In sleep mode, MSD will go to the Power save mode (320W 190W)

Laboratory Operating Cost Reduction (see the previous slide for detail)

Safety Control

• If 5977A MSD Pumps fail, 7890B will shut off the gas supply for protecting

GC/MSD system.

Cool Down MSD Faster (FastVent)

• When MSD Vent Cycle started, GC will cool down MSD analyzer at the

optimum gas flow to MSD.

Helium Carrier gas : This prevents wasting gas.

Hydrogen Carrier gas: This reduces the risk of explosion in MSD.

Less time to wait for cooling down MSD analyzer (40 min 25 min when cooling

down from 280C to 100C)

January 15, 2013

MassHunter GC/MS Acquisition for GC/MSD

Unified GC/MS Acquisition and

MassHunter Data Analysis; with

MSD ChemStation workflow for GC/MSD

January 15, 2013 19

GC/MSD Software

January 15, 2013 20

MassHunter Qual

MassHunter Quant MH

CS

MassHunter GC/MS Acquisition

And Use Either

MassHunter Data Analysis

OR

MSD ChemStation Data Analysis MSD ChemStation DA

G1701FA

The Value of G1701FA Software

All Inclusive G1701FA Software Package

• MassHunter GC/MS Acquisition

• MassHunter Quantitative Analysis

• MassHunter Qualitative Analysis

• MSD ChemStation Data Analysis

• 21CFR11 Compliance tools (Acquisition and

MH Quantitative Analysis)

• GC/MS and LC/MS Translators

Collated User Information

• Workflow guides, Video Tutorials, all in one

location

Support

• 1yr Upgrade, Updates, and Phone Support

• Training and Familiarization options

MSD ChemStation DA

MassHunter Qual

MassHunter Quant

January 15, 2013 21

MassHunter GC/MSD Rollout Plan

Feb 2013: • Add GC/MSD systems

– 5975 & 5977 Series GC/MSD

– 7890B & 7820A

– 7697A HSS

• Continue MassHunter GC/MS and GC

support

– 7000 Series Triple Quad GC/MS

– 7200 Series Q-TOF GC/MS

• MH DrugQuant

• GC and GC/MSD Data Analysis with

MassHunter OR MSD ChemStation

modes

Late 2013: • Expand Compatibility

– 5973 Network

– 6890 Network & 6850 GC

• MH EnviroQuant

January 15, 2013 22

23

ASK When can I start using

MassHunter if I buy a 5977

Series GC/MSD?

ANSWER Anytime!

Without added cost!

January 15, 2013

GC/MSD Acquisition Methods

MSD Productivity ChemStation MassHunter GC/MS Acquisition

January 15, 2013 24

GC/MS Acquisition Methods are Transparent

from MSD ChemStation to MassHunter GC/MS (Except PAL)

Migrate MSD ChemStation Data to MassHunter

January 15, 2013 25

Data

Data

Data

MassHunter Quant

MassHunter Qual

MSD ChemStation (.D)

WorkStation (.SMS)

Generic (.CDF)

Migrate MSD ChemStation Quantitative Methods to

MassHunter

January 15, 2013 26

MSD ChemStation (QDB.MTH)

WorkStation (.mth)

MassHunter Quant

Method

Method

Expanded Capabilities: 7890B/5977A Improving the Industry Standards for GC/SQ

Higher Ion Count • Extractor EI source

• Increased ion count

• S/N > 1500:1

• IDL < 10 fg (industry first)

• Improved thermal profile

Save Time & Energy •Sequence Scheduler

• “Standby” post run

• “Ready to run” from standby

• “Bake Mode” as needed

• Factory backflush option

• Fast Vent capability

• DS42i rough pump“standby”

power reduction

Safety/Protection • Vacuum failure Shut off gas (He or H2)

Better Vacuum by

Agilent Pump • New Agilent V304 Turbo

• TwisTorr • Molecular Drag technology

• Improved pumping light gases

• H2 (220 L/s); He (255 L/s)

• Agilent Floating Suspension

• Longer life

• Quiet operation

Faster Scanning • 20,000 u/s

• But best choice of fast

scanning GC/MS is GC/QTOF

7890B GC Features • EMF, calculator, etc.

All of 5975’s features also built in 5977, such as “Hot Gold Quad”, SIM/Scan,

Gain tuning, Triple-Axis Detector, Trace Ion Detection, Auto CI, etc..

January 15, 2013 27

28

7890B/5977A GC/MS Solution Portfolio Driving Business Value and Success

Proven 7890 and 5977 Reliability

MassHunter & ChemStation SW

Integrated Intelligence

Improved Performance

Greater Operating Efficiency

Expanded Accessories and Options