aeg battery charger
DESCRIPTION
Technical Details of AEG Battery ChargerTRANSCRIPT
www.powersupplysystems.com
PROTECT RCSRectifiers Chargers and DC SystemsSPRe - Single Phase RectifierTPRe - Three Phase Rectifier
24V – 110V10A – 500A
N
EW RANG
E N
EW RANGE
Designed for all industrial applications• Oil & Gas, Petrochemicals
Offshore, Onshore, Pipelines
• Energy and Power
Generation, Transmission, Distribution• Transportation
Rail, Airports, Shipping
• Water
Desalination, Treatment• Instrumentation & Process Control
Chemicals, Mining, Steel, Paper• All Industrial Applications
Robust, Reliable and FlexibleThese are the latest generation of robust, industrial
rectifiers, chargers and DC Systems from Saft Power
Systems. Using proven microprocessor controlledthyristor technology to provide high-reliability powersupply and battery charging capabilities.
A more flexible approach to providing exact solutions.Choose from: • Standard system configurations and• Customized systems - designed to comply
with precise specifications
>>
Brochure RCS.qxd:PROTECT_1_DE.qxd 7/12/07 15:34 Page 2
• Standard system configurations - cost effective,
short lead time solutions
• Customized systems - enhance the standard system
by selecting from an extensive range of options
• All systems built with advanced GCAU - Generic Control and Alarm Unit
• Communications system used to monitor and controlthe defined parameters locally or remotely.
• Choice of several types of batteries: - nickel-cadmium – vented or gas recombination- lead acid – vented or gas recombination
• Advance Battery Management• Parallel operation• Simplified maintenance• High MTBF and low MTTR
- Bespoke documentation; drawings, manuals- Total solutions – including switchgear, load distribution
• International Service support – comprehensive packages including;
• Product Services: Installation, Commissioning, Service Contracts...
• Site Services: Load testing, monitoring…
>> KEY FEATURES
NEW RANGENEW RANGE: PROTECT RCS INDUSTRIAL RECTIFIERS, CHARGERS & DC SYSTEMS
Protect RCS is an evolution of the highly successfulSPR/TPR range from Saft Power Systems which is installedglobally and used for all Industrial applications.
The main advance of the new Protect RCS range is theintroduction of the GCAU card which integrates more cutting-edge hardware functions.
The Protect RCS rectifiers are thyristor-controlled rectifierssuitable for charging nickel-cadmium or lead-acid batterieswhile supplying DC loads. They can also be used withoutbatteries as direct power supplies.
This new range of DC Systems is available in three levels:
• The first level consists of the Standard Rectifier
with a compact set of alarms.• The second level offers a set of Basic Options,
extensive functions and alarms.• The third level offers a full set of Extended Options,
extensive functions and alarms allowing customizationof the systems to comply with special customer requirements.
The rectifiers are built as independent modules, optionalequipment like distribution boards, diode droppers etc.are installed in separate cubicle sections.
Because of the high level of standardisation and integration, the design reduces the need for extensiveinternal wiring.
Cabinets are floor mounted and can be designed to meet special requirements. The batteries are mounted on free-standing racks or in cabinets together with or separated from the rectifier.
"GCAU" Generic Control and Alarm Unit (A1)
The main card is the GCAU (Generic Control and AlarmUnit). It performs measurements, control and processcontrol (charge process control) and provides a widerange of alarm and monitoring options, a user-friendlycontrol/display interface, and facilities for data loggingand remote communication.
The card has all the necessary controls to pilot single and three phase thyristor chargers. For three phase systems a driver card is connected to the GCAU card.
The GCAU card uses a fully digital control algorithm to ensure the required flexibility.
The GCAU card incorporates two micro controllers, usingthe latest micro controller technology to ensure a highdegree of safety.
The tasks of these micro controllers are:
• Process communication and Monitoring• Regulation and synchronization
Each micro controller has its specific dedicated task. One micro controller is dedicated to the control algorithm while the second takes care of alarm, communication and charge process tasks.
The two micro controllers check each other’s functionality and will shut down the system safely if an operating error is detected.
Brochure RCS.qxd:PROTECT_1_DE.qxd 7/12/07 15:34 Page 3
AC LineInput
InputTransformer
GCAU CARD
RectifierBridge
RippleFilter
RectifierFuse
Stabilizer (Option)
DCOutput
IsolatedSerialPortOut
TPC Board(Three phase)
Extended filter as option
Battery
ACVoltagePS
ThyristorGateControl
OVPinput
RectifierCurrentsense
RectifierVolatgesense
BatteryTemp.Sensor(Option)
BatteryCurrentSense(Option)
DCPC
Loadvoltagesense
AmbientTempSensor (Option)
RS232
RS485
SerialCommunicationBoard (Option)
RJ 4-4Connector
Front alpha numeric Display2 LED indicatorsKeyboard
RJ 4-4Connector
RelayBoard
(Option)
LED box(Option)
RemoteAlarmContacts
8 Multifunctionalspareinputs
Display: 9mm character height, two line by sixteen-character alpha numeric LCD with LED backlight.
SYSTEM DISPLAY
BLOCK DIAGRAM OF THE RECTIFIER
An extensive human interface ensures that all the importantparameters are accessible from the front panel. A large16 characters by 2 lines LCD unit displays all the relativeinformation to the user. A three push button keyboard is used with 2 LEDs (green and red) indicating the charger state.
The Display card is mounted on the front of the systemand is controlled by the GCAU card. It is a plug-in deviceand is connected through two RJ 4-4 connectors with a 4-wire cable. All data and necessary power supply voltages are transferred over this cable.
Brochure RCS.qxd:PROTECT_1_DE.qxd 7/12/07 15:34 Page 4
>> PROTECT RCS - SINGLE PHASE RANGE
NOMINAL NOMINAL STANDARD SYSTEMS & BASIC OPTIONS WEIGHT2
DC OUTPUT DC OUTPUT DIMENSIONS1 (APPROX)RECTIFIER VOLTAGE CURRENT
TYPE V A HEIGHT (MM) WIDTH (MM) DEPTH (MM) KG
24SPRe10 24 10 1200 600 821 85
24SPRe15 24 15 1200 600 821 95
24SPRe25 24 25 1200 600 821 105
24SPRe50 24 50 1200 600 821 160
24SPRe75 24 75 1200 600 821 180
24SPRe100 24 100 1200 600 821 195
48SPRe10 48 10 1200 600 821 95
48SPRe15 48 15 1200 600 821 100
48SPRe25 48 25 1200 600 821 145
48SPRe50 48 50 1200 600 821 200
48SPRe75 48 75 1600 600 821 295
110SPRe10 110 10 1200 600 821 110
110SPRe15 110 15 1200 600 821 145
110SPRe25 110 25 1200 600 821 190
110SPRe50 110 50 1600 600 821 345
1. Dimensions may vary for systems with Extended Options.
2. Weights may vary depending on selection of Basic Options and Extended Options.
Please consult Saft Power Systems for alternative systems.
(including systems with Basic Options)
APPLICATIONSDesigned to provide secure DC power for all Industrialapplications; for Oil & Gas and Petrochemical Plants,Power Stations and Substations, Water Treatment Plants,Manufacturing Plants, Airports, Railways, etc
• Navigational Aids• Emergency Lighting• Fire & Gas Detection Systems• Fire Fighting• Emergency Shutdown Systems• Radio & Telecommunications• Signaling• Telemetry
• Instrumentation & Process Control• Gas Turbine Control• Switchgear Tripping• Motor Starting• Lube-oil pump supply• Power Generation, Transmission
and Distribution
Brochure RCS.qxd:PROTECT_1_DE.qxd 7/12/07 15:34 Page 5
>> PROTECT RCS - THREE PHASE RANGE
NOMINAL NOMINAL STANDARD SYSTEMS & BASIC OPTIONS WEIGHT2
DC OUTPUT DC OUTPUT DIMENSIONS1 (APPROX)RECTIFIER VOLTAGE CURRENT
TYPE V A HEIGHT (MM) WIDTH (MM) DEPTH (MM) KG
24TPRe25 24 25 1200 600 821 145
24TPRe50 24 50 1200 600 821 185
24TPRe75 24 75 1200 600 821 250
24TPRe100 24 100 1600 600 821 285
24TPRe150 24 150 1600 600 821 305
24TPRe200 24 200 1600 600 821 345
24TPRe300 24 300 2000 600 821 *(4)
24TPRe400 24 400 2000 821
(2065 max)3 900 *(4)
24TPRe500 24 500 2000 821
(2065 max)3 900 *(4)
48TPRe25 48 25 1200 600 821 190
48TPRe50 48 50 1200 600 821 215
48TPRe75 48 75 1600 600 821 315
48TPRe100 48 100 1600 600 821 340
48TPRe150 48 150 1600 600 821 495
48TPRe200 48 200 1600 600 821 515
48TPRe300 48 300 2000 600 821 *(4)
48TPRe400 48 400 2000 821
(2065 max)3 900 *(4)
48TPRe500 48 500 2000 821
(2065 max)3 900 *(4)
110TPRe25 110 25 1200 600 821 215
110TPRe50 110 50 1600 600 821 365
110TPRe75 110 75 1600 600 821 495
110TPRe100 110 100 1600 600 821 520
110TPRe150 110 150 1600 600 821 585
110TPRe200 110 200 2000 821 770
(2065 max)3 900
110TPRe300 110 300 2000 821
(2065 max)3 900 *(4)
110TPRe400 110 400 2000 821 *(4)
(2065 max)3 900
110TPRe500 110 500 2080 1200 821 *(4)
1. Dimensions may vary for systems with Extended Options.
2. Weights may vary depending on selection of Basic Options and Extended Options.
3. Cabinet with additional fan cooling – top cover 65mm Height.
4. Weights on request.
Please consult Saft Power Systems for alternative systems.
(including systems with Basic Options)
Brochure RCS.qxd:PROTECT_1_DE.qxd 7/12/07 15:34 Page 6
SPECIFICATIONINPUT
Protect RCS single phase (SPRe) Single phase 230Vac ± 10%
OUTPUT
Nominal voltage (Udc) 24V 48V 110V (Other voltages available as non-standard option)
PROTECTION
ENVIRONMENTAL
• Polarity reversal of battery (blows battery fuse, optional) • Soft-start function 0 to 100% • Short-circuits • Limited to 100% of rated current • Internal DC fuse • Non-volatile storage of system parameters and user setting • Mains failure shutdown • Rectifier failure shutdown • High-voltage DC shutdown • Thermal protection
Acoustic noise Typical 45-65 dB(A)
Tropicalisation Suitable for ambient temperature and relative humidity specified aboveand for ambient air free from dust and corrosive gases.
Ambient temperature Operating: 0°C to + 40°C Derate from 40°C to 55°C by lowering the output current by 1.25% per °C.Storage: -25°C to +70°C
Static voltage regulation ± 0.5% under the following conditions:• at float charge• 0-100% DC load variation• input voltage ± 10%• input frequency ± 6%• temperature from 0°C to 40°C
Exceptional variations + 15 / -20% (functional)
Long-term stability of UDC 0.15% for 1000 hours
Temperature coefficient of UDC 0.18% per °C
Safety According to EN 50178 standard
Input/Output isolation 2500 VAC between input/output and electrical earth
Relative humidity Operation: from 20% to 95% non condensing.Storage: from 15% to 90% (in original packaging).
Altitude Up to 1000m, derate from 1000 to 4000m by lowering the output current by 7% per 1000 m.
Ripple Max 2% rms of nom. DC voltage, with a battery Ah capacity of 5 times the charger nom rating, battery connected (see our filter options).2.5% rms typical (max 5%) on rectifier output, battery not connected.
EMC emissions Generic emission standards EN 50081-2 and generic immunity standardsEN 50082-2 available as standard option.
Dynamic voltage regulation Using standard filter and the battery connected (capacity higher than 5 times I nom)Load step Deviation 10-90% -5% 90%-10% +5%
Range of operating voltage Floating charge 75% to 125% of Udc NominalHigh rate charge 75% to 135% of Udc NominalCommissioning charge 75% to 140% of Udc Nominal
Frequency 50Hz or 60Hz ± 6%
Protect RCS Three Phase (TPRe) Three phase 400Vac ± 10% Other voltages available as option
Charging characteristic Constant current / constant voltage (I/U as per IEC 478-1) during float charge
Insulation resistance > 200 MΩ, 500 VDC
Current regulation 0-2% of current limit
Brochure RCS.qxd:PROTECT_1_DE.qxd 7/12/07 15:34 Page 7
>> PRODUCT RANGE ARCHITECTURE
Architecture Documentation Cabinet Availability
A Standard RectifierSystem
(Building block)
StandardDocumentation
StandardSize
Short leadtime
Plus Basic Options
(Building block)
StandardDocumentation
StandardSize
Short leadtime
Plus Extended Options
Customized Documentation
Standardor optional size
Project dependent
The product range is configurable with three levels of architecture:
1
2
3
Cabinet construction
Floor Mounted 19” cabinetProtection degree IP21Colour RAL 7035 - Powdered textured paintingCabinet natural cooling (except TPRe 110V-400A and 110V-500A)Door with air inletRear panel with air outlet (φ 5mm punched panel) (requires 10 cm minimum clearance at the rear of the cabinet)Door swing 180 degrees with two key locksLogo/ Brand name on frontBottom open (vermin proof as option)Standard cable entry at the bottomStandard cable gland plate on the roofBottom opening (10 cm) for pallet truck handling facilitiesStandard labelling/nameplateStandard PVC cableStandard cable markingNone isolated aluminium earth bar (screwed directly in frame)
Electrical components
Terminal X1 and X2 (Mains, battery, load, common fault)Internal input power switch Q1Input transformer T1 (with taps 220V-230V-240V for SPRe and 380V-400V-415V for TPRe)Rectifier bridge (SPRe: mixed diode/thyristor bridge V1-V5, TPRe: 6-pulse bridge V1-V7)GCAU card A1 with non-volatile history and English display language + second language available (factory setting)TPC card A2 for TPRe onlyOutput filter L1-C1 ripple voltage < 5% RMS without batteryRectifier fuse F1Rectifier shunt R2Common fault remote alarm (changeover contact wired on terminal)The Display card (A300) and keyboard assembly (A310) are mounted on the front of the system
STANDARD SYSTEMThe Protect RCS range of systems have been pre-configuredwith a number of the most commonly requested features built-in as standard. These systems are available “off-the-shelf”
with standard drawings and standard user documentation.A Standard Rectifier System without additional optionsprovides a very cost effective, short lead time solution.
STANDARD SYSTEM
Availability of TPRe 300A, 400A and 500A systems is project dependent
Brochure RCS.qxd:PROTECT_1_DE.qxd 7/12/07 15:34 Page 8
>> STANDARD SYSTEM PLUS BASIC OPTIONS
The Standard System can be enhanced by the addition of some Basic Options. System specific drawing packages and userdocumentation will be automatically generated to reflect the actual options configuredA Standard Rectifier System with Basic Options provides a cost effective, short lead time solution with additionalsystem capabilities.
Option n° Basic options Select ( )
Alarm/signalling/measurement option
100 LED box signalling (A6) (all alarms, events, high rate charge, commissioning)101 First 8 relays card ( A5.1)102 Rectifier voltage analog DC meter (P2)103 Rectifier current analog DC meter (P1)104 Battery current analog DC meter (P3)105 Temperature alarm (bridge natural cool. ≤50A,+TH1 shutdown+TH2 alarm)
Temperature alarm (bridge forced cool. ≥75A, TH1 shutdown, +TH2 alarm+TH3 fan assisted)
Communication options
200 EIA232 SPG* communication (A71) - WINSPARC software required
201 EIA485 SPG* communication (A71 + A72) - WINSPARC software required
202 EIA485 SPG* PC side interface (one set for PC)203 WINSPARC software (CD-ROM + documentation)204 EIA232 MODBUS communication (A71)205 EIA485 MODBUS communication (A71 + A72)
Control and command options
300 Remote forced floating charge command
AC input options
400 Input fuse (without alarm) DIN (F34)401 Input fuse (without alarm) Cylindrical (F34)402 Input circuit breaker (without alarm) (Q1)403 Input contactor (K1) controlled by ON-OFF switch S1 on front door404 EMI filter (CE) (Z1) - mandatory for “CE” mark
Load options
500 Load fuse (without alarm) DIN (F23)501 Load fuse (without alarm) Cylindrical (F23)502 Load circuit breaker (without alarm) (Q2)503 Load Switch (handle inside the cabinet) (Q2)504 Blocking diode (V21)505 0.1% filter SPRe ≤ 25A (Telecom filter for 24V and 48V)506 1% filter
Battery options
600 Battery fuse (without alarm) DIN (F13)601 Battery fuse (without alarm) Cylindrical (F13)602 Battery circuit breaker (without alarm) (Q3)603 Battery Switch (handle inside the cabinet)604 Battery current limit/display (Battery shunt R3 same as rectifier shunt R2)605 Battery voltage temperature compensation (5 m length sensor wire) (NTC)606 Temperature sensor wires: 10m, 30m607 Battery Low Voltage Disconnect contactor (K2) I Battery same as I Rectifier608 VOM battery charging (Ni Cd gas recombination)609 Dual rate charge C15 100 battery monitoring board (A3)610 Single rate charge C15 100 monitoring board (A3)611 High Rate interlock: (high rate inhibited as load switch is ON)
Cabinet options
700 Cabinet heating resistor (230V) controlled by thermostat701 Eye bolts 702 IP42
*SPG = Saft Power Systems Protocol for GCAU.
Brochure RCS.qxd:PROTECT_1_DE.qxd 7/12/07 15:34 Page 9
WINSPARC SOFTWARE-SAMPLE SCREENSHOT
SPECIFICATION
WINSPARC SOFTWARE-SAMPLE SCREENSHOT
The WINSPARC software (WINDOWS based) is an applicationdesigned for local and remote supervision to have controlof the entire GCAU configuration in order to monitor andconfigure the systems.This software interacts with the GCAU through a serialdata link. To do this the communication card A71 is pluggedinto the GCAU through the extension connector (See options 200, 201 and 202).
This software function allows visualizing on a PC screensystem data such as alarms, measurements, modes, andhistory. Remote commands can be sent to the system.
The available types of communication are:• Locally (via PC port COMx)• Remotely (via Modem -extended option 250)
If only one charger is to be connected to the PC, the GCAU card has to be equipped with an isolatedEIA232/EIA485 communication extension board (A71).Option 200.
If more than one charger is to be connected to the samecommunication bus (centralized supervision of chargers),the GCAU card has to be equipped with an isolatedEIA232/EIA485 communication extension board (A71) +one EIA485 interface & connecting board (A72). Option 201.
With Option 201 (EIA485 bus), the PC side is usuallyequipped with a PC side interface providingEIA485/EIA232 conversion. Option 202.
The rectifiers are acting as slaves and the central comput-er as the master. By giving the different rectifiers differentslave numbers, it is possible to command each individualrectifier.
WINSPARC is compliant with the WINSITE software (site management application).
Platform: PC compatibleOperating system: Windows NT4, Windows 2000 or Windows XP.
Brochure RCS.qxd:PROTECT_1_DE.qxd 7/12/07 15:34 Page 10
>> FURTHER CUSTOMIZATION WITH EXTENDED OPTIONS
The Standard System can be enhanced by the addition of some Basic Options. System specific drawing packages and userdocumentation will be automatically generated to reflect the actual options configuredA Standard Rectifier System with Basic Options provides a cost effective, short lead time solution with additionalsystem capabilities.
Option n° Extended options Select ( )
Alarm /signalling/measurement options
150 LED Box LED test push button
151 AC input voltage analog meter (with phase selector switch for TPRe)
152 AC input current analog meter (with phase selector switch for TPRe)
153 AC input voltage and current analog meters with 3-phase selector switch
154 Load voltage analog DC meter
155 Load current analog DC meter
156 Additional spare input alarm (to centralize an external signalling with additional terminal and auxiliary relay – if isolated input required)
157 Second 8 relays signalling card (with additional auxiliary power supply required)
158 Alarm buzzer
159 High ripple voltage alarm
160 Low electrolyte level alarm
161 Battery circuit failure alarm
162 DC line permanent insulation controllers
See options Protection device (Fuse or MCB) with signalling alarm AC input, Load or Battery
163 Ambient temperature indicator/alarm
Communication options
250 Modem communication
Control and command options
350 Remote rectifier shutdown command (Using one spare input)
351 Remote alarm reset / acknowledgement command (Using one spare input)
352 Battery room fan control (One relay of extension relay card required)
353 Remote high rate charge command (Using one spare input)
354 Float/Auto/High rate internal switch (Using two spare inputs)
AC input options
450 Input fuse (with alarm) DIN
451 Input fuse (with alarm) Cylindrical
452 Input circuit breaker (with alarm)
453 Special transformer( earth screen, tapping, lower inrush current)
454 Special mains input voltage (3x460/480V 60Hz; 3x500V 50Hz; 3x690V 50Hz; other)
455 AC surge arrestor
Load options
550 Load fuse (with alarm) DIN
551 Load fuse (with alarm) Cylindrical
552 Load circuit breaker (with alarm)
553 Diode dropper
554 0.1% filter all other models SPRe ≥50A & TPRe
555 High DC voltage trip mechanical
556 DC distribution
557 DC surge arrestor
Brochure RCS.qxd:PROTECT_1_DE.qxd 7/12/07 15:34 Page 11
ONS
Option n° Extended options Select ( )
Battery options
650 Battery fuse (with alarm) DIN
651 Battery fuse (with alarm) Cylindrical
652 Battery circuit breaker (with alarm)
653 Special battery current limit/display shunt (R3 # R2)
654 Special battery LVD contactor (I batt. # I red.)
655 Reversed battery protection
656 Cable drop compensation
657 Battery protection/isolation box (Fuse/fuse switch/MCB/MCCB/switch)
See alarm options High ripple voltage alarm card
Low electrolyte level alarm
Battery circuit failure alarm card
See control options Battery room fan control
Float/Auto/High rate internal switch
Remote high rate charge command
Cabinet options
750 Cabinet interior light and AC mains socket with circuit breaker (without differential)
751 Cabinet interior light and AC mains socket with differential protection circuit breaker
752 Interior light with circuit breaker (without differential)
753 AC mains socket with differential protection MCB
754 AC mains socket with circuit breaker (without differential)
755 IP20 Open Door
756 IP21 with back panel
757 Protection up to IP54
758 Special colour
759 Copper earth bar
760 Vermin proof protection plate
761 Tropicalisation (Varnished PCB’s)
762 Special wiring (low smoke low fume wiring and cable duct halogen free)
763 Identification of internal components by sticky labels on plexi strip
764 Identification of internal components by engraved labels on plexi strip
765 Cabinet coupling
766 Cabinet separation plate
767 Additional cabinets option
768 Battery cabinet
769 Battery separation plate
System options
850 Parallel high rate - Automatic high rate inhibition for the chargers in parallel
851 Passive loadsharing (droop factor)
852 Shared high rate
Option n° Miscellaneous options Select ( )
950 Extra drawing files
951 Factory acceptance test
952 Extra test (Heat run test)
953 Packing (various categories)
954 Freight (as required)
Detailed explanations of all Options are available on request.
Miscellaneous options (Additional Miscellaneous Options can be selected and include);
Brochure RCS.qxd:PROTECT_1_DE.qxd 7/12/07 15:34 Page 12
Power SystemsWhenever wherever wattever
Industry - IT - Telecoms - Transportation - Services
For further information see SPS Service Brochure
For more information please refer to our website:
www.powersupplysystems.com
Rea
lized
by
yvyd
y. -
Pro
tect
RC
S -
09/0
7- E
N-V
1.
Due
to
our
polic
y of
con
tinuo
us d
evel
opm
ent,
dat
a in
thi
s do
cum
ent
is s
ubje
ct t
o ch
ange
with
out
notic
e an
d be
com
es c
ontr
actu
al o
nly
afte
r w
ritte
n co
nfirm
atio
n.
BATTERIESSaft Power Systems has considerable in-house knowledge inbattery technology and is able to offer expert advice on thespecifying, selection, operation and testing of batteries. Our total system solutions include a wide range of productsusing lead acid and nickel-cadmium batteries in vented and
gas recombination technologies. Batteries can be suppliedon racks or inside cabinets which match the chargers andcan be mechanically coupled to the charger cabinet if necessary.Replacement batteries can be supplied and installed by ourGlobal Service Team.
POWER SERVICESAdvanced power supplies require advanced technical
service and support. Our customers know that they can
count on Saft Power Systems specialists to deliver the
right service and support rapidly and efficiently.
A comprehensive range of services are availableProduct ServicesRefurbishmentConsultingLoad Bank & Capacity TestingInstallation & CommissioningFacility & equipment ManagementBattery MonitoringSpare Parts
Battery ReplacementIn-house/Express RepairTrainingRemote MonitoringPower Quality ServicesService Contracts - 24/7 Global Service CoverageCorrective MaintenanceDesign & Build - Turnkey Solutions
Brochure RCS.qxd:PROTECT_1_DE.qxd 7/12/07 15:34 Page 1