TRANSCRIPT

  • 205

    GREASE INTERCEPTORSGREASE INTERCEPTORSIN

    TERCEPTORS

    Grease Interceptor FeaturesA grease interceptor is a plumbing device installed in the sanitary drainage system to intercept fats, oils and grease (FOG) from the waste waterdischarge. It works by slowing the flow of water into the interceptor, which allows the FOG time to separate from the waste water. The FOG iscontained in the body of the interceptor allowing the FOG-free water to pass downstream by exiting the interceptor via a trap leg. Hydro-mechanicalgrease interceptors range in size from small 7 GPM units to large 500 GPM units. Units with installed grease removal devices are self-cleaning.For maximum grease efficiency JOSAM provides an external flow control with every interceptor which must be used as directed.

    60100H-GRD TIMER-CONTROLLED GREASE REMOVAL PUMP

    TIMER/CONTROLLERWall-mounted Programmable Timeractivates evacuation pump at pre-determined time (1-99 Days).

    GREASE REMOVAL PUMPevacuates contained grease regardless of temperature.

    EXTERNAL FLOW CONTROLWITH AIR INTAKE (Not Shown)

    REMOVABLE BAFFLE

    SECURED COVER (Removed)White acid-resisting coating,gasketed air and watertight,single-bolt, non-skid safety pattern.

    NO-HUBInlet/Outlet Connections

    BODYSteel with whiteacid-resisting coating

    INTERNALTRAP LEG

    RECLAIM CHAMBERprovides visual evidence thatgrease layer is removed, assuringcorrect interval has been selected.

    GRDP OPTIONincludes the sensing and alarm probe which enables the use of the probe as the primary source of sensing with the timer as a back-up system.

    Interceptors_08.qxd 3/27/08 11:58 AM Page 205

    WARNING: Cancer and Reproductive Harm - www.p65warnings.ca.gov

  • 206

    INTERCEPTORS INTERCEPTORSIN

    TERC

    EPTO

    RS

    This checklist of interceptors is provided as a guide to selection of the proper type interceptor to control specific waste materials. First determine the waste material to becontrolled, then follow the check marks for the types of interceptors recommended.

    How to OrderSelect Type Number from Dimension Table and use suffix numbers to indicate options.

    EXAMPLE: Series No. 60100H Type No. 6010

    60106H -EXT -ISI

    Type No.Option, Integral ExtensionOption, Integrated Solids Interceptor

    HOW TO ORDER INTERCEPTORS WITH EXTENDED TOPSWhen ordering extensions for Grease and Oil Interceptors (-EXT), specify dimension from the pipe centerline to finished floor.

    Selection Checklist

    TYPE OFWASTE

    MATERIAL

    TYPES OF INTERCEPTORS

    GREASE INTERCEPTORSOIL

    SEPARATORSSOLIDS INTERCEPTORS

    AUTOMATICSEMI-

    AUTOMATIC MANUAL AUTOMATIC

    Barium P PBenzine P P P P P PCheese P P P P P P P P P P P P P PCutting Oils P P P P P PElemental Mercury* PFats P P P P P P P P P P P P P PGasoline P P P P P PGauze P P PGlass Grindings PGravel P P P PGrease P P P P P P P P P P P P P PHair P P P PJewels P P PKerosene P P P P PLint P P P P PLubricating Oil P P P P P PNaphtha P P P P P POil P P P P P POil Sludge PParaffin P P P P P P P P P PPlaster P PPrecious Metals P P PQuench Oil P P P P P PRouge PRubber Grindings PSand P P P PSediment P P P PWax P P P P P P P P P P*Cast Iron Interceptor Only

    6010

    0H-G

    RD

    6030

    0A

    6010

    0-SA

    6011

    0-SA

    6010

    0-SA

    -RT

    6010

    0-SA

    -ET

    6010

    0H

    6011

    5A

    6011

    7A

    6010

    0H-E

    XT

    6010

    0H-R

    T

    6010

    0H-E

    T

    6021

    0A

    6021

    0A-E

    XT

    6050

    0B

    6050

    0B-E

    XT

    6050

    0-ES

    T

    6061

    0A

    6061

    0A-E

    XT

    6061

    0-ES

    T

    6081

    0

    6100

    0

    6103

    0

    6104

    0

    6107

    0

    6108

    0

    6180

    0

    Interceptors_08.qxd 3/27/08 11:58 AM Page 206

    WARNING: Cancer and Reproductive Harm - www.p65warnings.ca.gov

  • 207

    GREASE INTERCEPTORSGREASE INTERCEPTORSIN

    TERCEPTORS

    SizingConsult PDI-G101 or ASME A112.14.3 Standards or your local codes.

    Selection Table

    TYPE NO.RATING

    IN G.P.M.INLET & OUTLETSIZE (INCHES)

    AUTOMATIC TYPE

    60306A 25 3

    60307A 35 3

    60308A 50 3

    60309A 75 4

    60310A 100 4

    60311A 150 4

    60312A 200 6

    60313A 250 6

    60314A 350 6

    60315A 500 6

    SEMI-AUTOMATIC TYPE

    60102-SA, -RT, -ET 7 2

    60103-SA, -RT, -ET 10 2

    60104-SA, -RT, -ET 15 2

    60105-SA, -RT, -ET 20 3

    60106-SA, -RT, -ET 25 3

    60107-SA, -RT, -ET 35 3

    60108-SA, -RT, -ET 50 3

    SEMI-AUTOMATIC LOW TYPE

    60115-SA 35 3

    GREASE MONITORING DEVICE

    EGOLD-1000

    CEGOLD-2000

    -SAP

    TYPE NO.RATING

    IN G.P.M.INLET & OUTLETSIZE (INCHES)

    MANUAL CLEANING TYPE

    60102H, -EXT, -RT, -ET 7 2

    60103H, -EXT, -RT, -ET 10 2

    60104H, -EXT, -RT, -ET 15 2

    60105H, -EXT, -RT, -ET 20 3

    60106H, -EXT, -RT, -ET 25 3

    60107H, -EXT, -RT, -ET 35 3

    60108H, -EXT, -RT, -ET 50 3

    60109H, -EXT, -RT, -ET 75 3

    60110H, -EXT, -RT, -ET 100 4

    MANUAL CLEANING LOW TYPE

    60115A 20 2

    60117A 35 3

    MANUAL CLEANING HIGH VOLUME TYPE

    60213A, -EXT 150 4

    60214A, -EXT 200 5

    60215A, -EXT 250 5

    60216A, -EXT 350 6

    60217A, -EXT 500 6

    Interceptors_08.qxd 3/27/08 11:58 AM Page 207

    WARNING: Cancer and Reproductive Harm - www.p65warnings.ca.gov

  • INTERCEPTORS Pictorial Selection GuideINTERCEPTORS Pictorial Selection Guide

    208

    INTE

    RCEP

    TORS

    AUTOMATIC ELECTRONIC GREASE/OIL LEVEL DETECTORS60300AGI-2000A Fully Electronic SS Interceptor

    Page 219

    60100H-GRDGrease Removal Device

    Page 211

    EGOLD-1000Monitoring Device forInterceptors Inside Building

    Page 220

    CEGOLD-2000Monitoring Device forInterceptors Outside Building

    Page 220

    SAPSensing & Alarm Probe

    Page 217

    MANUAL CLEANING60115A/60117ALow-Boy

    Page 216

    60210AHigh Volume

    Page 217

    60210A-EXTHigh Volume, Extended Top

    Page 218

    MANUAL CLEANING60100HOn-Floor Type

    Page 211

    60100H-EXTExtended Top

    Page 212

    60100H-ETEnclosed Top

    Page 212

    60100H-RTRecessed Type

    Page 213

    SEMI-AUTOMATIC CLEANING60100-SAOn-Floor Type

    Page 214

    60100-SA-ETEnclosed Type

    Page 215

    60100-SA-RTRecessed Type

    Page 215

    60115-SALow Boy

    Page 216

    Interceptors_08.qxd 3/27/08 11:58 AM Page 208

    WARNING: Cancer and Reproductive Harm - www.p65warnings.ca.gov

  • INTERCEPTORS Pictorial Selection GuideINTERCEPTORS Pictorial Selection Guide

    209

    INTERCEPTO

    RS

    OIL SEPARATORS60500BGravity-Type Draw-Off

    Page 225

    60500B-EXTExtended Top, Draw-Off Type

    Page 225

    60500-ESTwith External Storage Tank

    Page 226

    OIL SEPARATORS60610AHigh Volume, Draw-Off Type

    Page 227

    60610A-EXTHigh Volume, Extended Top, Draw-Off Type

    Page 227

    60610-ESTHigh Volume with External Storage Tank

    Page 228 (EST NOT SHOWN)

    OIL/SEDIMENT LINT INTERCEPTOR60810

    Page 229

    61800Galvanized Steel Bucket

    Page 232

    SOLIDS INTERCEPTORS61000Barber Shop Type, Bottom Access

    Page 229

    61030Jewelry Shop Type, Top Access

    Page 229

    61040A18" x 18" Top Access

    Page 230

    61070 6108010-1/2" Top 16-1/2 Top

    Top Access

    Pages 230, 231

    Interceptors_08.qxd 3/27/08 11:58 AM Page 209

    WARNING: Cancer and Reproductive Harm - www.p65warnings.ca.gov

  • 210

    GREASE INTERCEPTORS GREASE INTERCEPTORSIN

    TERC

    EPTO

    RS

    Typical InstallationsThe typical illustrations shown below are suggested ways of installing various types of JOSAM Interceptors. All installations are subject togovernment and local code requirements.

    60100H Series Interceptor on floor, servicing a sink. 60110-SA Series Semi-Automatic shallow Interceptor installed onfloor, servicing a double compartment sink and dishwasher.

    60115A Series Interceptor installed on floor under sink.(Recommended only if there is adequate head room for coverremoval and service.)

    NOTE: Install air intake from flow control to outside of building and terminate with elbow, turned down or intersect a local vent or vent stack without trap if permittedby code. Top of air intake from flow control should not be lower than rim of fixture.

    60100H-EXT Series Interceptor recessed with deep roughingextended flush with floor.

    60100-SA-RT Series Semi-Automatic Interceptor recessed flush withfloor, servicing a dishwasher.

    60210A-EXT Series Interceptor recessed flush with floor, servicing asink and an additional fixture.

    Interceptors_08.qxd 3/27/08 11:58 AM Page 210

    WARNING: Cancer and Reproductive Harm - www.p65warnings.ca.gov

  • APPLICATIONFor use in restaurant and institutional kitchens and all types of food handling andprocessing areas where waste water contains fats, oil and grease (FOG). Adequatespace and head room for removal of cover must be available for manual cleaning.

    SPECIFICATIONJOSAM 60100H Series epoxy coated fabricated steel Grease Interceptor, no-hub connec-tions, internal trap, removable diffuser baffle, gasketed non-skid cover, flow control fittingand PDI Seal of Approval. Conforms to Plumbing & Drainage Institute Standard PDI-G101.

    Conforms to Plumbing and Drainage Institute Standard PDI-G101.

    Available Options-40 Cover Recess for Floor Finish-61 Flange and Clamp Device

    * -ISI Integrated Solids Interceptort -EXT Extension, 6 Standard.

    (Specify Extension Height)t -RT

Recommended

View more >