50-1,200 amp, -48 vdc vortex power system with 50 …voxtechnologies.com/marconi/pdf/2_31.pdfmodular...

4
LLP 2-31 LLP 2-31 LLP 2-31 LLP 2-31 LLP 2-31 Key Features Single Point Adjustment Single Point Adjustment Single Point Adjustment Single Point Adjustment Single Point Adjustment—no tools required to make settings and adjustments; one intelligence shelf controls up to 56 PCUs • Remote Access • Remote Access • Remote Access • Remote Access • Remote Access—options allow users to view, control and interact with all power systems in a network from a remote location • Plug’n’Play • Plug’n’Play • Plug’n’Play • Plug’n’Play • Plug’n’Play—add PCUs without adjustments and settings; no system shutdown • Front Accessible— • Front Accessible— • Front Accessible— • Front Accessible— • Front Accessible—allows for easy installation, additions and maintenance • Modular Design • Modular Design • Modular Design • Modular Design • Modular Design—simple to install and operate; allows users to grow system in cost- effective increments • High Density • High Density • High Density • High Density • High Density—compact design takes up less floor space; houses four PCUs per 10.5” (26.67cm) H x 23” (58.42cm) W shelf • Optional • Optional • Optional • Optional • Optional Temperature emperature emperature emperature emperature Compensation Compensation Compensation Compensation Compensation—provides automatic adjustment of PCU output voltage when battery temperature increases or decreases • Saf • Saf • Saf • Saf • Safety Compliance ety Compliance ety Compliance ety Compliance ety Compliance—UL listed to UL subject 1801 • NEBS Compliance • NEBS Compliance • NEBS Compliance • NEBS Compliance • NEBS Compliance 50-1,200 amp, -48 VDC Vortex ® Power System with 50 or 65 amp PCUs Description The Vortex power platform with 50 or 65 amp power conversion units (PCUs) is a modular power system providing up to 1,200 amps of power for -48 volt systems. The basic components of a Vortex power system include an intelligence shelf, which houses the meter–control–alarm microprocessor (MCA) and PCUs; expansion shelves for additional PCUs; and a modular distribution cabinet. The intelligence shelf can accommodate up to four PCUs, and the expansion shelves, also housing up to four PCUs each, can be added for larger load requirements. The intelligence and expansion shelves are 23" (58.42cm) wide x 10.5" (26.67cm) high. In addition to housing the PCUs, the intelligence shelf provides a powerful, microprocessor-based meter–control–alarm system which is capable of monitoring and controlling up to 56 PCUs. The front of the intelligence shelf provides a 16-character alphanumeric display which can be activated at the touch of a keypad. Vortex distribution is modular by row and position. The cabinet allows for up to four rows with a maximum of 96 positions. Users can combine any number of 1–150 amp circuit breakers and 1–50 amp TPA-style fuses to customize power plants. GJ-style circuit breakers and TPL-style fuses are also available. Application The Vortex system, powered with 50 or 65 amp PCUs, is ideal for wireline and wireless applications such as switch sites, remote cabinets, CEV and UE sites, customer premises and cell sites. Additional Information For additional specification, engineering and installation information, specify spec. number 582120000 (power system), 588700701 (200 amp power shelf and 50 amp PCUs) or 588703600 (260 amp power shelf and 65 amp PCUs). For ordering information, request drawing number SAG582120000, PD588700701 or PD588703600.

Upload: buianh

Post on 15-Mar-2018

233 views

Category:

Documents


2 download

TRANSCRIPT

Page 1: 50-1,200 amp, -48 VDC Vortex Power System with 50 …voxtechnologies.com/Marconi/pdf/2_31.pdfmodular power system providing up to 1,200 amps of power for -48 volt ... -48 VDC Vortex

LLP 2-31LLP 2-31LLP 2-31LLP 2-31LLP 2-31

Key Features

••••• Single Point Adjustment Single Point Adjustment Single Point Adjustment Single Point Adjustment Single Point Adjustment—notools required to makesettings and adjustments; oneintelligence shelf controls upto 56 PCUs

• Remote Access• Remote Access• Remote Access• Remote Access• Remote Access—optionsallow users to view, controland interact with all powersystems in a network from aremote location

• Plug’n’Play• Plug’n’Play• Plug’n’Play• Plug’n’Play• Plug’n’Play—add PCUswithout adjustments andsettings; no system shutdown

• Front Accessible—• Front Accessible—• Front Accessible—• Front Accessible—• Front Accessible—allows foreasy installation, additionsand maintenance

• Modular Design• Modular Design• Modular Design• Modular Design• Modular Design—simple toinstall and operate; allowsusers to grow system in cost-effective increments

• High Density• High Density• High Density• High Density• High Density—compact designtakes up less floor space;houses four PCUs per 10.5”(26.67cm) H x 23” (58.42cm)W shelf

• Optional • Optional • Optional • Optional • Optional TTTTTemperatureemperatureemperatureemperatureemperatureCompensationCompensationCompensationCompensationCompensation—providesautomatic adjustment of PCUoutput voltage when batterytemperature increases ordecreases

• Saf• Saf• Saf• Saf• Safety Complianceety Complianceety Complianceety Complianceety Compliance—UL listedto UL subject 1801

• NEBS Compliance• NEBS Compliance• NEBS Compliance• NEBS Compliance• NEBS Compliance

50-1,200 amp, -48 VDC Vortex® PowerSystem with 50 or 65 amp PCUsDescription

The Vortex power platform with 50 or 65 amp power conversion units (PCUs) is amodular power system providing up to 1,200 amps of power for -48 volt systems. Thebasic components of a Vortex power system include an intelligence shelf, which houses themeter–control–alarm microprocessor (MCA) and PCUs; expansion shelves for additionalPCUs; and a modular distribution cabinet.

The intelligence shelf can accommodate up to four PCUs, and the expansion shelves, alsohousing up to four PCUs each, can be added for larger load requirements. The intelligenceand expansion shelves are 23" (58.42cm) wide x 10.5" (26.67cm) high.

In addition to housing the PCUs, the intelligence shelf provides a powerful,microprocessor-based meter–control–alarm system which is capable of monitoring andcontrolling up to 56 PCUs. The front of the intelligence shelf provides a 16-characteralphanumeric display which can be activated at the touch of a keypad.

Vortex distribution is modular by row and position. The cabinet allows for up to four rowswith a maximum of 96 positions. Users can combine any number of 1–150 amp circuitbreakers and 1–50 amp TPA-style fuses to customize power plants. GJ-style circuitbreakers and TPL-style fuses are also available.

Application

The Vortex system, powered with 50 or 65 ampPCUs, is ideal for wireline and wireless applicationssuch as switch sites, remote cabinets, CEV and UEsites, customer premises and cell sites.

Additional Information

For additional specification, engineering andinstallation information, specify spec. number582120000 (power system), 588700701 (200 amppower shelf and 50 amp PCUs) or 588703600(260 amp power shelf and 65 amp PCUs).

For ordering information, request drawingnumber SAG582120000, PD588700701 orPD588703600.

Page 2: 50-1,200 amp, -48 VDC Vortex Power System with 50 …voxtechnologies.com/Marconi/pdf/2_31.pdfmodular power system providing up to 1,200 amps of power for -48 volt ... -48 VDC Vortex

50-1,200 amp, -48 VDC Vortex Power System with 50 or65 amp PCUsThe System

Distribution

LLP 2-32LLP 2-32LLP 2-32LLP 2-32LLP 2-32

One Row DistribOne Row DistribOne Row DistribOne Row DistribOne Row Distributionutionutionutionution FFFFFour Row Distribour Row Distribour Row Distribour Row Distribour Row Distributionutionutionutionution

Intelligence ShelfIntelligence ShelfIntelligence ShelfIntelligence ShelfIntelligence Shelf

The Vortex platform includes a modular distribution product line that can be designed with one to four panels. Eachmodular panel can be configured with any combination of distribution positions, low voltage disconnect and batterydisconnect. Distribution cabinets are front accessible, modular in design and are initially configured in the factory.The cabinets are 24.375" (58.42cm) wide, 17.5” (44.45cm) deep andvary in height depending on the capacity. Circuit breakers and/orfuse modules snap into the multi-position distribution blocks toprovide for easy installation. For larger device requirements, TPL-style fuses and GJ-style breakers are available up to 600 amp ratings.

Intelligence Shelf

A front access intelligence shelf houses up to four PCUs. Availableshelf ratings are 200 amps (with 50 amp PCUs) or 260 amps (with65 amp PCUs). The intelligence shelf includes the MCA, whichprovides a single point of adjustment for such features as floatvoltage, test/equalize voltage, high voltage shutdown and currentlimit adjustments for all PCUs in the entire power system. Theintelligence shelf allows users to view specific alarm conditions,system measurements and system settings. All adjustments can beperformed locally via the alphanumeric display panel on the frontof the intelligence shelf or remotely via optional software andhardware. The MCA provides local indicators and the ability totransmit various alarm conditions such as PCU failure, highvoltage shutdown and AC failure.

Page 3: 50-1,200 amp, -48 VDC Vortex Power System with 50 …voxtechnologies.com/Marconi/pdf/2_31.pdfmodular power system providing up to 1,200 amps of power for -48 volt ... -48 VDC Vortex

50-1,200 amp, -48 VDC Vortex Power System with 50 or65 amp PCUsExpansioExpansioExpansioExpansioExpansion Sn Sn Sn Sn Shehehehehelflflflflf

A standard 7’ high power system can contain one to fourfront-access expansion shelves, each of which houses up tofour PCUs. Available shelf ratings are 200 amp (with 50amp PCUs) and 260 amp (with 65 amp PCUs). Theexpansion shelves are 23" (58.42cm) wide, 10.5" (26.67cm)high and 14.88" (37.78cm) deep.

Power Conversion Units

The modular, high frequency, switch-mode Vortex PCUsare the foundation of the Vortex platform. Plug’n’play technology allows for easy system configuration. System capacity canbe increased by simply plugging an additional PCU into an existing intelligence or expansion shelf — no adjustments orsetup is required. The Vortex power system can house up to 20 PCUs which provide load power, battery float current andbattery recharge current. The PCUs are monitored and controlled by the intelligence shelf. The PCUs allow the user toappropriately size a power plant (50 to 1,200 amps) to meet specific applications.

Power Conversion Unit Specifications

InputVoltage: Nominal 208/240 volts AC, single phase, 50/60 Hz,with a range of 176 to 264 volts. Extended range is 150 voltsAC to 290 volts AC (50 amp unit only).Inrush Current: Peak does not exceed 2 times the RMSinput at full load, under any conditions of input voltagewithin the rated input voltage range.Frequency: 45–70 HzProtection: Each PCU is individually wired andconnections for individual AC input branch circuits areprovided. If the AC input voltage decreases or increasesbeyond a non-adjustable predetermined value, the PCUpower conversion circuitry inhibits, disabling PCU output.The PCU will recover automatically when the AC inputvoltage is re-established within specifications limits.Typical Power Factor: Greater than or equal to 98% for anyload greater than or equal to 50% of rated full load atnominal line. Meets IEC 1000–3–2.Typical Operating Efficiency: 90% at full load.

OutputVoltage: Nominal -48 volts DC, Positive Ground.Current: 50 amps per PCU, up to a total of 200 amps pershelf with four PCUs installed. 65 amps per PCU, up to atotal of 260 amps per shelf with four PCUs installed.Regulation: Steady state output voltage remains within±0.5% of any voltage within the range of 44.0 to 58.0 voltsDC (44.0 to 57.0 volts DC for 65 amp PCUs) for anycombination of frequency, normal input voltage, and loadfrom no load to full load over the temperature range of-20° C to +65° C (-4° F to +149° F) for 50 amp PCUs, -20°C to +50° C (-4° F to +122° F) for 65 amp PCUs.Filtering: On or off batteryVoice Band Noise — Less than 32 dBrndCWide Band Noise — Does not exceed 500 mv peak-to-peak,or 30 mv rmsPsophometric Noise — Does not exceed 1 mv

LLP 2-33LLP 2-33LLP 2-33LLP 2-33LLP 2-33

Easy System ExpEasy System ExpEasy System ExpEasy System ExpEasy System Expansionansionansionansionansion

Page 4: 50-1,200 amp, -48 VDC Vortex Power System with 50 …voxtechnologies.com/Marconi/pdf/2_31.pdfmodular power system providing up to 1,200 amps of power for -48 volt ... -48 VDC Vortex

LLP 2-34LLP 2-34LLP 2-34LLP 2-34LLP 2-34

© 2000 Marconi Communications Inc.Printed in the USA. All rights reserved. Any unauthorizedreproduction or transmission without the prior consent ofMarconi Communications Inc. is prohibited.

wwwwwwwwwwwwwww.marcon i .com.marcon i .com.marcon i .com.marcon i .com.marcon i .com/pow/pow/pow/pow/powerererererMarconi CommunicationsMarconi CommunicationsMarconi CommunicationsMarconi CommunicationsMarconi Communications1122 F StreetLorain, OH 44052800-800-1280Fax: 440-246-4876

50-1,200 amp, -48 VDC Vortex Power System with 50 or65 amp PCUsPower Conversion Unit Specifications (continued)

ProtectionCurrent Limiting — Maximum output current of eachPCU can be set from 10% to 110% (105% maximum for 65amp PCU) of full load current.High Voltage Shutdown — If PCU output voltage exceedsan adjustable preset value, the PCU shuts down. Afterapproximately three seconds, the PCU automaticallyrestarts.DC Output Breakers — Connects or disconnects PCUoutput power to/from the PCUs output terminals.

Status/Alarm Indicators and MeteringExtensive alarming and status indicators such as AC on/off,fan fail, PCU failure and open sense are displayed on the16–character numerical display of the intelligence shelf andon the PCUs within the shelf.

EnvironmentalOperating Temperature:-40° C to +65° C (-40° F to +149° F) for 50 amp PCUs,-20° C to +50° C (-4° F to +122° F) for 65 amp PCUStorage Temperature: -40° C to +85° C (-40° F to +185° F)Humidity: 0% to 95% relative humidity, non-condensingAltitude: The maximum operating ambient temperatureshould be derated by +10° C (+50°F) at an elevation of10,000' (3,048m) above sea level. For elevations between3,000' (914m) and 10,000' (3,048m), derate the maximumoperating ambient temperature linearly.

Ventilation: Fan-cooled front to rearEMI/RFI Suppression: Conforms to FCC rules Part 15,Subpart B, Class A with an option for FCC and CISPR22Class B emission ratings.Audible Noise: 3' from any vertical surface does not exceed65dBA; 50dBA with low fan speed selected.

Physical CharacteristicsMounting: Plug-in installationDimensions:Width: 5.13" (13.02cm)Height: 9.88" (25.08cm)Depth: 14.5" (36.83cm)Weight: 18 lbs. (8.16 kgs)

Safety ComplianceUL Recognized (UL 1950)CSA 22.2, No. 950CE

Vortex® and Lorain® are trademarks of Marconi Communications Inc.

50 or 65 amp50 or 65 amp50 or 65 amp50 or 65 amp50 or 65 amp,,,,,-48 V-48 V-48 V-48 V-48 Volt Powolt Powolt Powolt Powolt PowerererererConversion UnitConversion UnitConversion UnitConversion UnitConversion Unit