  • Residual Current Breaker With Overload Protection

    www.mebamfg.com

    OLLB7 Residual Current Breaker With Overload Protection

    Brand Name: MebaModel Number: OLLB7Type: Residual Current Breaker With Overload Protection(RCBO)Poles Number: 2P

    36

    35.6

    0.3

    45

    44.56677 0.8

    5.5

    800.

    8

    Dimensions(mm): Operation Principle Fig:

    1 N

    2 N

    H

    Specification:

    OLLB7 RCBO, function as combination of circuit breaker and residual curre nt device, which protec t human from the fault of electric because of over-cu rrent, short circuit, earth fault current. OLLB7 is self-protecting up to a maximum short-circuit current 63A. All breaking capacities comply with Standard IEC/EN 61009.

    Technical parameter:

    Residual current device with overcurrent protectionCombine in residual current device function and MCB over-current protection functionShort circuit capacity: 6KARated current(A): 6, 16, 20, 25, 32, 40, 50, 63ARated leakage operating current(mA): 30, 100, 300mAAC and A types, B-C characteristicModular Din Rail products 35mm.

    OLLB7

    127

    MPFIM4

    www.mebamfg.com

    Residual Current Circuit Breaker

    128

    MPFIM4 Residual Current Circuit Breaker

    Earth Leakage Circuit Breaker(ELCB), Residual Current Device(RCD), Residual Current Circuit Breaker(RCCB)Brand Name: MebaModel Number: MPFIM4Type: Residual Current Circuit Breaker or Residual Current DevicePoles Number: 4P

    Specification:

    MPFIM4, Residual Current Devices for earth leakage detection. It is to be used in association with miniature circuit breakers, its function is to detect earth leakage current and open the connected circuit to protect people and equipment, major used in industrial app lication. These devices are designed to meet the Earth Leakage Protection Standards of the IEC: IEC/EN 61008.

    Technical parameter:

    Electromagnetic and Electronic type35mm wide for 4 pole Din Rail installation.Standsrd: IEC1008/EN61008Rated Voltage(Un): 2pole, 230V ACRated Current(In): 25, 40, 63ARated residual operating current(In): 30, 100, 300, 500mARated residual non-operating current(Ino): 0.5 InResidual current off-time: 0.1sMinimum value of rated breaking capacity(lm): 630ARated conditional short-circuit capacity (lnc): 6KA

    Dimensions:77 0.8

    35.6

    0.3

    44.566

    5.5

    4583

    0.8

    35.5 0.372

    66.3

    0.3

    36

  • www.mebamfg.com

    Specification:

    Technical parameter:

    Specification:

    Technical parameter:

    CF-362 Residual Current Circuit Breaker

    www.mebamfg.com

    Residual Current Circuit Breaker

    Residual Current Circuit Breaker

    Earth Leakage Circuit Breaker(ELCB), Residual Current Device(RCD), Residual Current Circuit Breaker(RCCB)Brand Name: MebaModel Number: CF-362Type: Residual Current Circuit Breaker or Residual Current Device Poles Number: 2P

    Specification:

    CF-362, Residual Current Devices for earth leakage detection. It is to be used in association with miniature circuit breakers, its function is to detect earth leakage current and open the connected circuit to protect people and equipment, major used in industrial application. These devices are designed to meet the Earth Leakage Protection Standards of the IEC: IEC/EN 61008.

    Technical parameter:

    Electromagnetic and Electronic type35mm wide for 2 pole Din Rail installation.Standsrd: IEC1008/EN61008Rated Voltage(Un): 2pole, 230V ACRated Current(In): 25, 40, 63ARated residual operating current(I n): 30, 100, 300, 500mARated residual non-operating current(I no): 0.5 I nResidual current off-time: 0.1sMinimum value of rated breaking capacity(lm): 630ARated conditional short-circuit capacity (lnc): 6KA

    CF-364 Residual Current Circuit BreakerEarth Leakage Circuit Breaker(ELCB), Residual Current Device(RCD), Residual Current Circuit Breaker(RCCB)Brand Name: MebaModel Number: CF-364Type: Residual Current Circuit Breaker or Residual Current Device) Poles Number: 4P

    Specification:

    CF-364, Residual Current Devices for earth leakage detection. It is to be used in association with miniature circuit breakers, its function is to detect earth leakage current and open the connected circuit to protect people and equipment , major used in industrial application. These devices are designed to meet the Earth Leakage Protection Standards of the IEC: IEC/EN 61008.

    Technical parameter:

    Electromagnetic and Electronic type70mm wide for 4 pole Din Rail installation.Standsrd: IEC1008/EN61008Rated Voltage(Un): 4pole, 400V ACRated Current(In): 25, 40, 63ARated residual operating current(I n): 30, 100, 300, 500mARated residual non-operating current(I no): 0.5 I nResidual current off-time: 0.1sMinimum value of rated breaking capacity(lm): 630ARated conditional short-circuit capacity (lnc): 6KA

    CF-462 Residual Current Circuit Breaker

    Earth Leakage Circuit Breaker(ELCB), Residual Current Device(RCD), Residual Current Circuit Breaker(RCCB)Brand Name: MebaModel Number: CF-462Type: Residual Current Circuit Breaker or Residual Current Device Poles Number: 2P

    CF-462, Residual Current Devices for earth leakage detection. It is to be used in association with miniature circuit breakers, its function is to detect earth leakage curre nt and open the connected circuit to protect people and equipment, major used in industrial application. These devices are designed to meet the Earth Leakage Protection Standards of the IEC: IEC/EN 61008.

    Electromagnetic and Electronic type35mm wide for 2 pole Din Rail installation.Standsrd: IEC1008/EN61008Rated Voltage(Un): 2pole, 230V ACRated Current(In): 25, 40, 63ARated residual operating current(I n): 30, 100, 300, 500mARated residual non-operating current(I no): 0.5 I nResidual current off-time: 0.1sMinimum value of rated breaking capacity(lm): 630ARated conditional short-circuit capacity (lnc): 6KA

    CF-464 Residual Current Circuit BreakerEarth Leakage Circuit Breaker(ELCB), Residual Current Device(RCD), Residual Current Circuit Breaker(RCCB)Brand Name: MebaModel Number: CF-464Type: Residual Current Circuit Breaker or Residual Current Device) Poles Number: 4P

    CF-464, Residual Current Devices for earth leakage detection. It is to be used in association with miniature circuit breakers, its function is to detect earth leakage current and open the connected circuit to protect people and equipment, major used in industri al application. These devices are designed to meet the Earth Leakage Protection Standards of the IEC: IEC/EN 61008.

    Electromagnetic and Electronic type70mm wide for 4 pole Din Rail installation.Standsrd: IEC1008/EN61008Rated Voltage(Un): 4pole, 400V ACRated Current(In): 25, 40, 63ARated residual operating current(I n): 30, 100, 300, 500mARated residual non-operating current(I no): 0.5 I nResidual current off-time: 0.1sMinimum value of rated breaking capacity(lm): 630ARated conditional short-circuit capacity (lnc): 6KA

    CF-362 CF-364 CF-462 CF-464

    129 130

  • www.mebamfg.com

    Specification:

    Technical parameter:

    Specification:

    Technical parameter:

    CF-362 Residual Current Circuit Breaker

    www.mebamfg.com

    Residual Current Circuit Breaker

    Residual Current Circuit Breaker

    Earth Leakage Circuit Breaker(ELCB), Residual Current Device(RCD), Residual Current Circuit Breaker(RCCB)Brand Name: MebaModel Number: CF-362Type: Residual Current Circuit Breaker or Residual Current Device Poles Number: 2P

    Specification:

    CF-362, Residual Current Devices for earth leakage detection. It is to be used in association with miniature circuit breakers, its function is to detect earth leakage current and open the connected circuit to protect people and equipment, major used in industrial application. These devices are designed to meet the Earth Leakage Protection Standards of the IEC: IEC/EN 61008.

    Technical parameter:

    Electromagnetic and Electronic type35mm wide for 2 pole Din Rail installation.Standsrd: IEC1008/EN61008Rated Voltage(Un): 2pole, 230V ACRated Current(In): 25, 40, 63ARated residual operating current(I n): 30, 100, 300, 500mARated residual non-operating current(I no): 0.5 I nResidual current off-time: 0.1sMinimum value of rated breaking capacity(lm): 630ARated conditional short-circuit capacity (lnc): 6KA

    CF-364 Residual Current Circuit BreakerEarth Leakage Circuit Breaker(ELCB), Residual Current Device(RCD), Residual Current Circuit Breaker(RCCB)Brand Name: MebaModel Number: CF-364Type: Residual Current Circuit Breaker or Residual Current Device) Poles Number: 4P

    Specification:

    CF-364, Residual Current Devices for earth leakage detection. It is to be used in association with miniature circuit breakers, its function is to detect earth leakage current and open the connected circuit to protect people and equipment , major used in industrial application. These devices are designed to meet the Earth Leakage Protection Standards of the IEC: IEC/EN 61008.

    Technical parameter:

    Electromagnetic and Electronic type70mm wide for 4 pole Din Rail installation.Standsrd: IEC1008/EN61008Rated Voltage(Un): 4pole, 400V ACRated Current(In): 25, 40, 63ARated residual operating current(I n): 30, 100, 300, 500mARated residual non-operating current(I no): 0.5 I nResidual current off-time: 0.1sMinimum value of rated breaking capacity(lm): 630ARated conditional short-circuit capacity (lnc): 6KA

    CF-462 Residual Current Circuit Breaker

    Earth Leakage Circuit Breaker(ELCB), Residual Current Device(RCD), Residual Current Circuit Breaker(RCCB)Brand Name: MebaModel Number: CF-462Type: Residual Current Circuit Breaker or Residual Current Device Poles Number: 2P

    CF-462, Residual Current Devices for earth leakage detection. It is to be used in association with miniat