4210 lb-1343 rev b fibulock brochure - surgical...

2
SPECIFICATIONS Syndesmosis Screws Catalog # Label Description CO3540-D 3.5mm x 40mm Quick Thread Cortical Screw CO3545-D 3.5mm x 45mm Quick Thread Cortical Screw CO3550-D 3.5mm x 50mm Quick Thread Cortical Screw CO3555-D 3.5mm x 55mm Quick Thread Cortical Screw CO3560-D 3.5mm x 60mm Quick Thread Cortical Screw CO3565-D 3.5mm x 65mm Quick Thread Cortical Screw CO3570-D 3.5mm x 70mm Quick Thread Cortical Screw 40, 45, 50, 55, 60, 65, 70mm 3.5mm 6mm 2.5 mm Distal Screws Catalog # Label Description SC2712 2.7mm x 12mm Self Tapping Cortical Screw SC2714 2.7mm x 14mm Self Tapping Cortical Screw SC2716 2.7mm x 16mm Self Tapping Cortical Screw SC2718 2.7mm x 18mm Self Tapping Cortical Screw SC2720 2.7mm x 20mm Self Tapping Cortical Screw 2.7mm 5mm 2.0mm References 1. K.E. Bugler, T.O. White, P.T. Appleton, M.M. McQueen and C.M. Court-Brown. A Prospective, Randomised Controlled Trial Of A Fibular Nail Versus Standard Open Reduction And Internal Fixation For Fixation Of Ankle Fractures In Elderly Patients. Bone Joint J 2013 vol. 95-B no. SUPP 25 8 2. Avilucea F, et al. The Costs of Operative Complications for Ankle Fractures: A Case Control Study. Advances in Orthopedics. 2014 Ankle Fracture System STRENGTH FROM WITHIN™ Prior to the use of the Sonoma Orthopedic Products FibuLock™ nail system, the surgeon should refer to the product instruction for use (IFU) for complete indications, warnings, precautions and contra indications. Package inserts are also available by contacting Sonoma Orthopedic Products, Inc. The Gold Standard Changed It’s NowTime for In the 1970s, intramedullary nails supplanted surgical plates as the gold standard for treating femoral and tibial fractures. Nails are now generally accepted as advantageous over plates because nails: • Reduce skin and soft-tissue trauma • Decrease infection rates • Are load sharing instead of load bearing to expedite patient rehabilitation • Cause less patient pain with fewer requests for implant removal The Sonoma FibuLock nail is the first intramedullary device that has the same indications as plates and delivers anatomic reductions with all of the other advantages of intramedullary nailing. IN THE 1970s! FIBULA NAILING Forceps hold reduction Fibular reaming FibuLock nail Implantation FibuLock Holds Your Reduction In most cases, the fibula can be reduced percutaneously with slight traction and the application of forceps. However, surgeons can use the same reduction methods they would use for a plate through a much smaller incision. STRENGTH FROM WITHIN™ Spanning COMMINUTION Like femoral and tibial nails, the FibuLock nail is an excellent solution for comminuted fractures. The FibuLock nail can be used to span a highly comminuted portion of the fibula to avoid making an incision over the fragmented bone. The nail then holds the fibula to length and rotation while the soft-tissue envelope maintains the bone fragments in proximity for healing. Despite these advantages, fibula fractures are still predominantly repaired with surgical plates. Plates generally deliver an anatomic reduction, but require a substantial incision and frequently cause patient discomfort with subsequent removal. Peer-reviewed literature demonstrates incision-site infections and healing are significant issues which surgeons take multiple precautions to avoid. Locks Anatomic Reductions for Weber A, B and C Fractures Syndesmosis screws L/M screws Single A/P screw 30 o 25 o Sonoma Orthopedic Products, Inc. 1388 Busch Parkway Buffalo Grove, IL 60089 847-807-4378 Phone 847-947-8082 Fax www.sonomaorthopedics.com TM Trademarks and ® Registered Marks of Sonoma Orthopedic Products, Inc. ©2015 Sonoma Orthopedic Products, Inc. All Rights Reserved USA Patents 7,846,162; 7,909,825; 7,914,533 and 7,942,875 USA and International Patents Pending LB-1343 Rev B MediTech Strategic Consultants B.V. Maastrichterlaan 127-129 6291 EN Vaals Catalog # Label Description FIB30130L 3.0x130mm Sonoma FibuLock™ Nail, Standard Left FIB30130R 3.0x130mm Sonoma FibuLock™ Nail, Standard Right FIB30180L 3.0x180mm Sonoma FibuLock™ Nail, Long Left FIB30180R 3.0x180mm Sonoma FibuLock™ Nail, Long Right FIB38130L 3.8x130mm Sonoma FibuLock™ Nail, Standard Left FIB38130R 3.8x130mm Sonoma FibuLock™ Nail, Standard Right FIB38180L 3.8x180mm Sonoma FibuLock™ Nail, Long Left FIB38180R 3.8x180mm Sonoma FibuLock™ Nail, Long Right 13mm 40mm 30mm 19mm 14mm 10mm 6 o 130mm & 180mm 5mm & 6mm *Available upon request * * End Cap Catalog # Label Description FIB6000 Sonoma FibuLock™ Nail End Cap Medial Malleolus Screw Washer Catalog # Label Description WA4000 4.0mm Medial Malleolus Bone Screw Washer 7mm 4mm 0.8mm Medial Malleolar Screws (cannulated) Catalog # Label Description CA4040-C 4.0mm x 40mm Cancellous Screw, Cannulated CA4045-C 4.0mm x 45mm Cancellous Screw, Cannulated CA4050-C 4.0mm x 50mm Cancellous Screw, Cannulated CA4055-C 4.0mm x 55mm Cancellous Screw, Cannulated CA4060-C 4.0mm x 60mm Cancellous Screw, Cannulated 4.0mm 6mm 2.7mm 40, 45, 50, 55, 60mm 6mm 3mm & 3.8mm

Upload: dominh

Post on 07-Jul-2018

226 views

Category:

Documents


1 download

TRANSCRIPT

Page 1: 4210 LB-1343 Rev B Fibulock Brochure - Surgical …surgicalinnovations.co.nz/.../uploads/2016/08/Fibulock-Brochure.pdf · MediTech Strategic ... delivering the same union and reduction

SPECIFICATIONS

Syndesmosis ScrewsCatalog # Label DescriptionCO3540-D 3.5mm x 40mm Quick Thread Cortical ScrewCO3545-D 3.5mm x 45mm Quick Thread Cortical ScrewCO3550-D 3.5mm x 50mm Quick Thread Cortical ScrewCO3555-D 3.5mm x 55mm Quick Thread Cortical ScrewCO3560-D 3.5mm x 60mm Quick Thread Cortical ScrewCO3565-D 3.5mm x 65mm Quick Thread Cortical ScrewCO3570-D 3.5mm x 70mm Quick Thread Cortical Screw

40, 45, 50, 55, 60, 65, 70mm3.5mm

6mm2.5 mm

Distal ScrewsCatalog # Label DescriptionSC2712 2.7mm x 12mm Self Tapping Cortical ScrewSC2714 2.7mm x 14mm Self Tapping Cortical ScrewSC2716 2.7mm x 16mm Self Tapping Cortical ScrewSC2718 2.7mm x 18mm Self Tapping Cortical ScrewSC2720 2.7mm x 20mm Self Tapping Cortical Screw

2.7mm

5mm2.0mm

References1. K.E. Bugler, T.O. White, P.T. Appleton, M.M. McQueen and C.M. Court-Brown. A Prospective, Randomised Controlled Trial Of A Fibular Nail Versus Standard Open Reduction And Internal Fixation For Fixation Of Ankle Fractures In Elderly Patients. Bone Joint J 2013 vol. 95-B no. SUPP 25 8

2. Avilucea F, et al. The Costs of Operative Complications for Ankle Fractures: A Case Control Study. Advances in Orthopedics. 2014

Ankle Fracture System

STRENGTH FROM WITHIN™Prior to the use of the Sonoma Orthopedic Products FibuLock™ nail system, the surgeon should refer to the product instruction for use (IFU) for complete indications, warnings, precautions and contra indications. Package inserts are also available by contacting Sonoma Orthopedic Products, Inc.

The Gold Standard Changed

It’s Now Time for

In the 1970s, intramedullary nails supplanted surgical plates as the gold standard for treating femoral and tibial fractures.

Nails are now generally accepted as advantageous over plates because nails: • Reduce skin and soft-tissue trauma • Decrease infection rates • Are load sharing instead of load bearing to expedite patient

rehabilitation • Cause less patient pain with fewer requests for implant removal

The Sonoma FibuLock™ nail is the first intramedullary device that has the same indications as plates and delivers anatomic reductions with all of the other advantages of intramedullary nailing.

IN THE 1970s!

FIBULA NAILINGForceps hold

reduction

Fibularreaming

FibuLock™ nail Implantation

FibuLock™ Holds Your ReductionIn most cases, the fibula can be reduced

percutaneously with slight traction and the application of forceps. However, surgeons can use the same reduction methods they would use for a plate through a much smaller incision.

STRENGTH FROM WITHIN™

Spanning COMMINUTIONLike femoral and tibial nails,

the FibuLock™ nail is an excellent solution for comminuted fractures.

The FibuLock™ nail can be used to span a highly comminuted portion of the fibula to avoid making an incision over the fragmented bone. The

nail then holds the fibula to length and rotation while the soft-tissue envelope maintains the bone

fragments in proximity for healing.

Despite these advantages, fibula fractures are still predominantly repaired with surgical plates. Plates generally deliver an anatomic reduction, but require a substantial incision and frequently cause patient discomfort with subsequent removal. Peer-reviewed literature demonstrates incision-site infections and healing are significant issues which surgeons take multiple precautions to avoid.

Locks Anatomic Reductions for Weber A, B and C Fractures

Syndesmosis screws

L/M screws

Single A/P screw

30o

25o

Sonoma Orthopedic Products, Inc.1388 Busch ParkwayBuffalo Grove, IL 60089847-807-4378 Phone847-947-8082 Faxwww.sonomaorthopedics.com

TM Trademarks and ® Registered Marks of Sonoma Orthopedic Products, Inc. ©2015 Sonoma Orthopedic Products, Inc. All Rights Reserved USA Patents 7,846,162; 7,909,825; 7,914,533 and 7,942,875USA and International Patents Pending

LB-1343 Rev B

MediTech Strategic Consultants B.V.Maastrichterlaan 127-1296291 EN Vaals

Catalog # Label DescriptionFIB30130L 3.0x130mm Sonoma FibuLock™ Nail, Standard LeftFIB30130R 3.0x130mm Sonoma FibuLock™ Nail, Standard RightFIB30180L 3.0x180mm Sonoma FibuLock™ Nail, Long LeftFIB30180R 3.0x180mm Sonoma FibuLock™ Nail, Long RightFIB38130L 3.8x130mm Sonoma FibuLock™ Nail, Standard LeftFIB38130R 3.8x130mm Sonoma FibuLock™ Nail, Standard RightFIB38180L 3.8x180mm Sonoma FibuLock™ Nail, Long LeftFIB38180R 3.8x180mm Sonoma FibuLock™ Nail, Long Right

13mm

40mm30mm

19mm14mm

10mm

6o

130mm & 180mm

5mm & 6mm

*Available upon request

**

End CapCatalog # Label Description

FIB6000 Sonoma FibuLock™ Nail End Cap

Medial Malleolus Screw WasherCatalog # Label Description

WA4000 4.0mm Medial Malleolus Bone Screw Washer

7mm

4mm 0.8mm

Medial Malleolar Screws (cannulated)Catalog # Label DescriptionCA4040-C 4.0mm x 40mm Cancellous Screw, Cannulated CA4045-C 4.0mm x 45mm Cancellous Screw, CannulatedCA4050-C 4.0mm x 50mm Cancellous Screw, CannulatedCA4055-C 4.0mm x 55mm Cancellous Screw, CannulatedCA4060-C 4.0mm x 60mm Cancellous Screw, Cannulated

4.0mm

6mm2.7mm

40, 45, 50, 55, 60mm

6mm3mm

& 3.8mm

Page 2: 4210 LB-1343 Rev B Fibulock Brochure - Surgical …surgicalinnovations.co.nz/.../uploads/2016/08/Fibulock-Brochure.pdf · MediTech Strategic ... delivering the same union and reduction

STEP 1 | REDUCE THE FRACTUREThe lateral malleolus may be reduced percutaneously before reaming.

STEP 4 | PREPARE THE DISTAL FIBULA Drive the 6.2mm tapered reamer over the K-wire. Drive a flexible guide wire through the reamer into the proximal fibula.

STEP 5 | REAM PROXIMALLYSequentially ream the proximal canal using the proximal reamers

STEP 6 | IMPLANTATION Insert the implant and activate the talons

STEP 7 | INSERT SCREWS Insert the compression, distal and syndesmosis screws

STEP 2 | ENTRY POINTAlign the entry point with the long axis of the fibula in the lateral view. Aim for the canal center in the A/P view.

STEP 3 | STARTING K-WIRE Drive the K-wire across the fracture line

Mechanisms to MAINTAIN STABILITYMost biomechanical research indicates the fibula sees 4% to 15% of body weight through

mild compressive, bending and rotational loads. The FibuLock™ nail stabilizes the fractured canal against these forces with four mechanisms:

1. Proximal triangulation talons – Unlike other long bones, the fibula has a triangular cross section. The talons of the FibuLock™ nail are designed to engage the apexes of the triangular canal geometry to resist compression and rotation.

2. Shaft interference fit – The shaft locks into the canal as it is forced to flex in response to the slight curvature of the bone

3. Multiplanar locking screws – Provide distal fixation 4. Compression mechanism – Increases proximity of bone fragments if necessary

Due to these stability and alignment mechanisms, the FibuLock™ nail is indicated for Weber A (high), B and C ankle fractures.

Reduced COST AND COMPLICATIONSA recent study investigated whether intramedullary nailing of fibula fractures would reduce the incidence of wound and implant issues while

delivering the same union and reduction rates as surgical plates. The study compared 50 plate and 50 intramedullary nail patients. The average patient age was 74-years-old and 75% were women. Functional results were slightly better for the intramedullary nail group, and the following table lists the complication results at 12-months.1

In addition, the costs of treating intramedullary patients were lower. This finding is supported by a 2014 study by The Vanderbilt Orthopaedic Institute Center for Health Policy which examined the hospital economic impact of plate repair complications in patients with isolated ankle fractures without associated injuries.2 Infections (1.8%) and hardware-related pain (2.3%) added $78,000 and $39,000 respectively to the cost of treating each patient. If the increased expense for this small subset of patients was distributed across all 439 patients within the study, it would add $2,300 to the cost of each patient’s care.

PLATES

NUMBER OF PATIENTSNUMBER OF PATIENTS

8

COMPLICATION

Wound Infections 0

PERCENTAGE OF TOTALPERCENTAGE OF TOTAL

16% 0 0.002

NAILS P VALUE

Fibula cross section with FibuLock™ multiplanar screws (distal view)

Fibula cross section with FibuLock™ talons deployed (proximal view)

Surgical TECHNIQUE

1

2

3

4

Simple SYNDESMOSISThe anatomic angulation of the FibuLock™ nail combined

with the screw targeting outrigger ensures the syndesmosis screw will be parallel to the plafond. “Quick Thread” screws bore into bone twice as fast as traditional screws to expedite the procedure.

Patented COMPRESSIONThe FibuLock™ nail features a patent-pending

mechanism that provides 2.5mm of compression.

Removal TECHNIQUE

STEP 1 | REMOVE THE END CAP AND SCREWS WITH A 2.5MM HEX DRIVER

STEP 2 | DEACTIVATE THE TALONS The talons will close during extraction

STEP 3 | EXTRACT WITH THE SLAPHAMMER

Plate Features In A Nail… SYNDESMOSIS FIXATION, COMPRESSION and REMOVAL

STRENGTH FROM WITHIN™

SYNDESMOSIS FIXATION• 3.5mm screws (40-70mm)• Accommodates suture-button fixation• Nail geometry ensures screws are parallel to the plafond

COMPRESSION SLOT AND SCREW• Allows 2.5mm of compression

END CAP (OPTIONAL)• Locks in compression• Prevents bone ingrowth

MULTIPLANAR SCREWS• 2.7mm cortical • Locking

TRIANGULATION TALONS• Provide proximal fixation• Over 4,000 implantations without a known breakage

SPECIFICATIONS:• 3.0mm and 3.8mm diameters• 130mm and 180mm lengths• 316L stainless steel