Page 1: 30 GHz waveguide line modification towards 12 GHz

30 GHz waveguide line modification towards 12 GHz.

Page 2: 30 GHz waveguide line modification towards 12 GHz

CTF3

CTF2

Overmoded 90 bend

Mode converter

CTF3

CTF2

Customized 90 degrees WR90 H bend

RF/vac. Gate valve

Current 30 GHz layoutModification towards 12 GHz

Vac. Pumping port

H10-> H01 mode converter (CEA)

Ø36 ->Ø50 matched taper (CEA)

Ø50 circular waveguide (existing line)

The gate valve and vacuum port are the new components for our group. I recommend to adopt our fresh designs (see next page) for their low price and high performance.Otherwise we can use already existing gate valve designed by CEA (quite bulky and expensive it also requires two mode converters) and pumping ports being design for stand along power source (they are quite long!). TBD.

Directional coupler

Page 3: 30 GHz waveguide line modification towards 12 GHz

Mini UHV gate valve

+ = Compact RF/vacuum gate valve

New components based on existing/tested RF designs

Compact RF/vacuum pumping port

(design)

pumping port

CLIC choke mode flange

Existing T-splitter To be re-placed by vacuum flange

Page 4: 30 GHz waveguide line modification towards 12 GHz

CEA based CEA + CERN

H10 -> H01 Mode converters:

Circular tapers:

Gate valves:

Pumping ports:

Directional couplers:RF load

8 (incl. 4 for 2 gate valves) (prototypes exist, needed to be ordered from industry)

2 bodies (prototypes exist, needed to be ordered from industry)

3 (prototypes exist, needed to be ordered from industry)

4 (prototypes exist, needed to be ordered from industry)

4 (prototypes exist, needed to be ordered from industry) 4 (prototypes exist, needed to be ordered from industry) 2 units. Needed technical design

3 units. Needed technical (little) design

The components table

The additional WR90 waveguide straight sections, bends and splitters to connect the structure and klystron’s line are not counted, should be defined when complete layout is ready.

2 units 1 units

Page 5: 30 GHz waveguide line modification towards 12 GHz

Other developments towards 5 MW klystrons cluster and new 50 MW

stations

Page 6: 30 GHz waveguide line modification towards 12 GHz

Compact SLED-type X-band pulse compressor. Design & components by F. Peauger, CEA.

H01 Mode Converter F36mm Short circuit

+ pumping port

H0 1 31 Cavity

H01 Circular Taper (F36mm→ F50mm)

IrisHybrid

To Accelerating Structure

From Klystron

SLAC-type Double height 3 dB hybrid

KEK-type compact H10-H01 mode converter

H01 tapers (36->50)

These components were designed and fabricated by CEA as a French in-kind contribution to the 12 GHz klystron station waveguide network at CERN

H01M ‘rugby’ cavityMode: H0,1,31

Length: 420mmMax. : 110 mmQ0: 1.82x105 (HFSS)

Currently we anticipating to furnish 6x50 MW stations. With development of a klystron cluster and collaboration with KVI (and others?), another 6 klystron could appear, thus at least 12 pulse compressors are needed to be build. CERN-CEA design uses existing components (mode converter, taper and hybrid). It needs technical support to design of the cavities and the whole system to be complete. The work should be done in collaboration with CEA. We should not consider other supplier (GYCOM) due to steady decay of their production quality.

Page 7: 30 GHz waveguide line modification towards 12 GHz

The components table for x12 pulse compressors

H10 -> H01 Mode converters:

Circular tapers:

Cavities:

Hybrids:

24 (prototypes exist, needed to be ordered from industry)

24 bodies (to be designed) 12 (many prototypes exist, needed to be ordered from industry)

24 (prototypes exist, needed to be ordered from industry)

Additional: - Every klystron channel should be equipped with 2 gate valves and 2 pumping ports, so we should foresee extra 24 valves and 24 pumping ports.- For diagnostic and power termination at least 12 directional coupler and 12 RF loads will be needed.

Page 8: 30 GHz waveguide line modification towards 12 GHz

H10 -> H01 Mode converters: 28

Circular tapers: 28

Hybrids: 12

Gate valves: 26

Pumping ports: 27

Directional couplers: 14

RF loads: 13

Overall summary of components I’ve considered that for the valve and pumping port we can use our new design

Page 9: 30 GHz waveguide line modification towards 12 GHz

Other business

Page 10: 30 GHz waveguide line modification towards 12 GHz

11 11.2 11.4 11.6 11.8 12 12.2 12.4 12.6 12.8 13-70

-60

-50

-40

-30

-20

-10

0"OFF" case

Frequency [GHz]

S P

aram

eter

s [d

B]

S41

S31

S21

S11

11 11.2 11.4 11.6 11.8 12 12.2 12.4 12.6 12.8 13-70

-60

-50

-40

-30

-20

-10

0"ON" case

Frequency [GHz]

S P

aram

eter

s [d

B]

S41

S31

S21

S11

11 11.2 11.4 11.6 11.8 12 12.2 12.4 12.6 12.8 13-70

-60

-50

-40

-30

-20

-10

0"OFF" case

Frequency [GHz]

S P

aram

eter

s [d

B]

S41

S31

S21

S11

11 11.2 11.4 11.6 11.8 12 12.2 12.4 12.6 12.8 13-70

-60

-50

-40

-30

-20

-10

0"ON" case

Frequency [GHz]

S P

aram

eter

s [d

B]

S41

S31

S21

S11

11 11.2 11.4 11.6 11.8 12 12.2 12.4 12.6 12.8 13-70

-60

-50

-40

-30

-20

-10

0"OFF" case

Frequency [GHz]

S P

aram

eter

s [d

B]

S41

S31

S21

S11

11 11.2 11.4 11.6 11.8 12 12.2 12.4 12.6 12.8 13-70

-60

-50

-40

-30

-20

-10

0"ON" case

Frequency [GHz]

S P

aram

eter

s [d

B]

S41

S31

S21

S11

11 11.2 11.4 11.6 11.8 12 12.2 12.4 12.6 12.8 13-70

-60

-50

-40

-30

-20

-10

0"OFF" case

Frequency [GHz]

S P

aram

eter

s [d

B]

S41

S31

S21

S11

11 11.2 11.4 11.6 11.8 12 12.2 12.4 12.6 12.8 13-70

-60

-50

-40

-30

-20

-10

0"ON" case

Frequency [GHz]

S P

aram

eter

s [d

B]

S41

S31

S21

S11

Compact variable splitter/attenuator

The existing (GYCOM) attenuators are bulky , have 10% Ohmic losses and ~6 ns group delay. In the future we will need such a devices to connect the existing TBTS PETS with CLEX module PETSes. The new attenuator design is based on CLIC components. The other place for splitter to be used is an interface between structure testing area and dog-leg RF line.At least 3 units will be needed.

CLIC E-plane hybrid

CLIC variable reflector