21_3_ps1800 bomba solar sumergible

Upload: jelurmi50505150

Post on 03-Apr-2018

234 views

Category:

Documents


0 download

TRANSCRIPT

  • 7/28/2019 21_3_PS1800 Bomba Solar Sumergible

    1/10

    PS1800 Centr ifugal Pumping SystemsGeneral Data and Sizing Tables

    The curve show the performance range of 4 models at 1800Wpsolar array

    - irradiation of 6kWh/m on a tilted surface- ambient temperature 30C

    Solar tracking will improve performance by aprox 40%

    Application:- drinking water supply- livestock watering- pond management- irrigation

    0

    10

    20

    30

    40

    50

    Pump Lift RangeSJ 12-3 2- 12m head

    SJ 8-5 2- 25m head

    SJ 5-8 2- 40m head

    SJ 3-9 20- 50m head

    Curve is based onIrradiation 6kWh/m day, tilted surface

    Pump ends:

    SJ -xx =centrifugal pump

    Motor:

    brushless DC, maintenance free

    LORENTZ offers standard solar pumpsolutions up to 230m (760ft) head and

    special solutions up to 750m (2500ft)

    head. Ask for charts

    met

    erhead

    SJ12-3

    SJ8-5

    SJ5-8

    SJ3-9

    Solar Pumping System / Capacity Diagram6kWh/m/day, 1800Wp solar array

  • 7/28/2019 21_3_PS1800 Bomba Solar Sumergible

    2/10

    Head Metres /Ft.

    US

    GPD m/day

    Direct operated PV-Pump System :

    Solar Pump System PS1800 C-SJ3-9

    C-SJ3-9

    - 1% cable loss

    Calculation of system performance is based on:

    - non tracked PV-generator, (see ETATRACK for increasing performance)- 11h standard solar day- ambient average temperature of 30C

    40/132

    35/116

    30/100

    25 /83

    50/165

    Wp

    900

    800

    700

    600

    500

    400

    300

    5

    10

    15

    20

    25

    30

    35

    40

    45

    1000

    2000

    3000

    4000

    5000

    7000

    8000

    9000

    11000

    10000

    6000

  • 7/28/2019 21_3_PS1800 Bomba Solar Sumergible

    3/10

    System PerformanceAn irradiation value and the required head in metersare given for a certain solar pumping system.By connecting the point for the power output in Wpof the solar array with an irradiation value, movevertical upwards to the intersection with the requiredhead curve, then horizontal to the left to find thedaily quantity of water that can be pumped ( m/day)Or the other way:

    By starting from the daily required water amounthorizontally to the intersection of the required head,then vertically down to the intersection with theexpected solar irradiation, then horizontally to theleft to find the required output of the solar array.

    Instantaneous Output

    MotorThe LORENTZ submersible motor, type EC1200-C is a 2 pole synchronous brushless DCmotor. Slide ring bearing and ceramic trustbearings are water lubricated.The motor raw earth magnets are hermeticallysealed in stainless steel and encapsulated insynthetic resin.The motor is pressure compensated and thereare no practical depth limitations forsubmergence.No electronics are inside the motor and theentire motor is water filled.

    Data:Voltage 3 X 100V electronicall commutated

    A B C D Emax BSP

    SJ 3A-9 546 186 360 96 98 1 1/4" 11,5 kg

    Pump TypeMinimum Internal Diameter

    of BoreholeWeight

    4" (104mm)

    Dimensions [mm]

    0,0

    0,5

    1,0

    1,5

    2,0

    2,5

    3,0

    3,5

    4,0

    4,5

    5,0

    5,5

    6,0

    200 400 600 800 1000 1200 1400 1600DC Power [W]

    flowr

    ate[m/h]

    0

    100

    200

    300

    400

    500

    600

    700

    800

    900

    1000

    1100

    1200

    1300

    1400

    1500

    flowr

    ate[

    USgal/h]

    PS1800 C-SJ3-9 (Item No. 1160 ) for Solar Operation(Solar generator: Nominal voltage 72 to 96 V DC, open circuit voltage max. 200V DC)

    Instantaneous Output 25 m / 82 ft

    35 m / 115 ft

    45 m / 148 ft

    55 m / 180 ft

    50 m / 164 ft

    30 m / 98 ft

    40 m / 131 ft

    Average Values

  • 7/28/2019 21_3_PS1800 Bomba Solar Sumergible

    4/10

    Head Metres /Ft.

    US

    GPD m/day

    Direct operated PV-Pump System :Solar Pump System PS1800 C-SJ5-8

    C-SJ5-8

    - 1% cable loss

    Calculation of system performance is based on:- non tracked PV-generator, (see ETATRACK for increasing performance)- 11h standard solar day- ambient average temperature of 30C

    10/335 /16.5

    15/49.5

    Wp

    1000

    900

    800

    700

    600

    500

    400

    300

    10

    20

    30

    40

    50

    60

    70

    2500

    5000

    10000

    7500

    12500

    15000

    17500

    20/66

    25/82.5

    30/100

    35/115.5

    40/132

    45/148.5

    50/165

    80

  • 7/28/2019 21_3_PS1800 Bomba Solar Sumergible

    5/10

    System PerformanceAn irradiation value and the required head in metersare given for a certain solar pumping system.By connecting the point for the power output in Wpof the solar array with an irradiation value, movevertical upwards to the intersection with the requiredhead curve, then horizontal to the left to find thedaily quantity of water that can be pumped ( m/day)

    Or the other way:

    By starting from the daily required water amounthorizontally to the intersection of the required head,then vertically down to the intersection with theexpected solar irradiation, then horizontally to theleft to find the required output of the solar array.

    Motor

    The LORENTZ submersible motor, type EC1200-C is a 2 pole synchronous brushless DCmotor. Slide ring bearing and ceramic trustbearings are water lubricated.The motor raw earth magnets are hermeticallysealed in stainless steel and encapsulated insynthetic resin.The motor is pressure compensated and thereare no practical depth limitations for

    submergence.No electronics are inside the motor and theentire motor is water filled.

    Data:Voltage: 3 X 100V electronically commutatedPower: 1,4kW / 2HP

    0,0

    1,0

    2,0

    3,0

    4,0

    5,0

    6,0

    7,0

    8,0

    9,0

    10,0

    11,0

    12,0

    0 200 400 600 800 1000 1200 1400 1600DC power [W]

    flowr

    ate[m/h]

    0

    200

    400

    600

    800

    1000

    1200

    1400

    1600

    1800

    2000

    2200

    2400

    2600

    2800

    3000

    flowr

    ate[USgal/h]

    PS1800 C-SJ5-8 (Item No. 1162 ) for Solar Operation(Solar generator: Nominal voltage 72 to 96 V DC, open circuit voltage max. 200V DC)

    5 m / 16 ft

    10 m / 33 ft

    15 m / 49 ft

    20 m / 66 ft

    25 m / 82 ft

    30 m / 98 ft

    35 m / 115 ft

    40 m / 131 ft

    45 m / 148 ft

    50 m / 164 ft

    Instantaneous Output Average Values

    A B C D Emax BSP

    SJ 5A-8 525 186 339 96 98 1 1/2" 11,2 kg

    Pump TypeMinimum Internal Diameter

    of BoreholeWeight

    4" (104mm)

    Dimensions [mm]

  • 7/28/2019 21_3_PS1800 Bomba Solar Sumergible

    6/10

    Head Metres /Ft.

    US

    GPD m/day

    Direct operated PV-Pump System :

    Solar Pump System PS1800 C-SJ8-5

    C-SJ8-5

    - 1% cable loss

    Calculation of system performance is based on:

    - non tracked PV-generator, (see ETATRACK for increasing performance)- 11h standard solar day- ambient average temperature of 30C

    10/33

    5 /16.5

    15/49.5

    Wp

    1000

    900

    800

    700600

    500

    400

    300

    10

    20

    30

    40

    50

    60

    70

    5000

    10000

    15000

    20/66

    25/82.5

    30/100

    80

    90

    100

    110

    120

    130

    20000

    25000

    30000

  • 7/28/2019 21_3_PS1800 Bomba Solar Sumergible

    7/10

    System Performance

    An irradiation value and the required head in metersare given for a certain solar pumping system.By connecting the point for the power output in Wpof the solar array with an irradiation value, movevertical upwards to the intersection with the requiredhead curve, then horizontal to the left to find thedaily quantity of water that can be pumped ( m/day)

    Or the other way:

    By starting from the daily required water amounthorizontally to the intersection of the required head,then vertically down to the intersection with theexpected solar irradiation, then horizontally to theleft to find the required output of the solar array.

    Motor

    The LORENTZ submersible motor, type EC1200-C is a 2 pole synchronous brushless DCmotor. Slide ring bearing and ceramic trustbearings are water lubricated.The motor raw earth magnets are hermeticallysealed in stainless steel and encapsulated insynthetic resin.The motor is pressure compensated and thereare no practical depth limitations for

    submergence.No electronics are inside the motor and theentire motor is water filled.

    Data:Voltage: 3 X 100V electronically commutatedPower: 1,4kW / 2HP

    0

    2

    4

    6

    8

    10

    12

    14

    16

    18

    0 200 400 600 800 1000 1200 1400 1600DC power [W]

    flowr

    ate[m/h]

    0

    500

    1000

    1500

    2000

    2500

    3000

    3500

    4000

    4500

    flowra

    te[USgal/h]

    PS1800 C-SJ8-5 (Item No. 1164) for Solar Operation(Solar generator: Nominal volt age 72 to 96 V DC, open circu it vo ltage max. 200V DC)

    5 m / 16 ft

    10 m / 33 ft

    15 m / 49 ft

    20 m / 66 ft

    25 m / 82 ft

    30 m / 98 ft

    Instantaneous Output Average Values

    A B C D Emax BSP

    SJ 8A-5 601 186 415 96 98 2" 12,7 kg

    Pump TypeMinimum Internal Diameter

    of BoreholeWeight

    4" (104mm)

    Dimensions [mm]

  • 7/28/2019 21_3_PS1800 Bomba Solar Sumergible

    8/10

    Head Metres /Ft.

    USGPD m/day

    Direct operated PV-Pump System :Solar Pump System PS1800 C-SJ12-3

    C-SJ12-3

    - 1% cable loss

    Calculation of system performance is based on:

    - non tracked PV-generator, (see ETATRACK for increasing performance)- 11h standard solar day- ambient average temperature of 30C

    12.5/41

    10/33

    7.5/25

    5 /16.5

    15/50

    Wp

    800

    700

    600

    500400

    300

    20

    40

    60

    80

    100

    120

    140

    160

    180

    200 2.5/8

    5000

    10000

    20000

    15000

    25000

    30000

    35000

    40000

    45000

    50000

  • 7/28/2019 21_3_PS1800 Bomba Solar Sumergible

    9/10

    System Performance

    An irradiation value and the required head in metersare given for a certain solar pumping system.By connecting the point for the power output in Wpof the solar array with an irradiation value, movevertical upwards to the intersection with the requiredhead curve, then horizontal to the left to find thedaily quantity of water that can be pumped ( m/day)

    Or the other way:

    By starting from the daily required water amounthorizontally to the intersection of the required head,then vertically down to the intersection with theexpected solar irradiation, then horizontally to theleft to find the required output of the solar array.

    Motor

    The LORENTZ submersible motor, type EC1200-C is a 2 pole synchronous brushless DCmotor. Slide ring bearing and ceramic trustbearings are water lubricated.The motor raw earth magnets are hermeticallysealed in stainless steel and encapsulated insynthetic resin.The motor is pressure compensated and thereare no practical depth limitations for

    submergence.No electronics are inside the motor and theentire motor is water filled.

    Data:Voltage: 3 X 100V electronically commutatedPower: 1,4kW / 2HP

    0

    2

    4

    6

    8

    10

    12

    14

    16

    18

    20

    22

    24

    0 200 400 600 800 1000 1200 1400 1600DC power [W]

    flowr

    ate[m/h]

    0

    500

    1000

    1500

    2000

    2500

    3000

    3500

    4000

    4500

    5000

    5500

    6000

    flowra

    te[USgal/h]

    PS1800 C-SJ12-3 (Item No. 1166) for Solar Operation(Solar generator: Nominal volt age 72 to 96 V DC, open circu it vo ltage max. 200V DC)

    5 m / 16 ft

    10 m / 33 ft

    15 m / 49 ft

    12,5 m / 41 ft

    7,5m / 25 ft

    Instantaneous Output Average Values

    A B C D Emax BSP

    SJ 12A-3 566 186 380 96 98 2" 12,5 kg

    Pump TypeMinimum Internal Diameter

    of BoreholeWeight

    4" (104mm)

    Dimensions [mm]

  • 7/28/2019 21_3_PS1800 Bomba Solar Sumergible

    10/10

    Depth of Well

    Tank Height

    Well to Basin

    Cable Length

    Trans. Pipe Diameter

    Riser Pipe Diameter

    Well Diameter

    Trans. Pipeline Length

    Static Level

    Drawdown

    Pump Intake Depth