1.mcb -meba

Download 1.MCB -Meba

Post on 28-Jul-2015

48 views

Category:

Sales

1 download

Embed Size (px)

TRANSCRIPT

1. 08 Technical parameter: Pole Rated Voltage(Un) Rated Current IN Rated frequency fN Rated breaking capacity Energy limiting class Tripping characteristic 1, 2, 3, 4 230(240)/400(415)V AC, max.60V DC 0.5-63A 50HZ 6KA 3 B,C,D B EN 50022 18mm/pole IEC 60898, EN60898 2 1-25mm Isolating class Mounting on the rail Build-in width Standards Cross-section of connecting lead 77=0.8 45 35.6=0.3 44 65.7 5.5 80=0.8 18 Dimensions(mm): Operation Principle Fig: 1Pole 1 2 2Pole 1 2 3 4 N N 3Pole 1 2 3 4 5 6 4Pole 1 2 3 4 5 6 8 7 N N Technical parameter: Pole Rated Voltage(Un) Rated Current IN Rated frequency fN Rated breaking capacity Energy limiting class Tripping characteristic 1, 2, 3, 4 230(240)/400(415)V AC, max.60V DC 0.5-63A 50HZ 6KA 3 B,C,D B EN 50022 18mm/pole IEC 60898, EN60898 2 1-25mm Isolating class Mounting on the rail Build-in width Standards Cross-section of connecting lead 77=0.8 45 35.6=0.3 44 65.7 5.5 80=0.8 18 Dimensions(mm): Operation Principle Fig: 1Pole 1 2 2Pole 1 2 3 4 N N 3Pole 1 2 3 4 5 6 4Pole 1 2 3 4 5 6 8 7 N N OLB7-1P/2P Miniature Circuit Breaker OLB7-3P Miniature Circuit Breaker www.meba.net Miniature Circuit Breaker OLB7-3POLB7-1P/2P 2. BH Miniature Circuit Breaker Features and Applications: BH seriesminiature circuit breakeris characteristicof smallsize, light weight,novel structure and excellent performance. They are mounted in the illuminating distribution board and used in guest house s, block of flats, high buildings, squar es, airports, railway stations, plants and enterprises etc. inACcircuits 240V (single pole) up to 415V(3 pole) 50Hz for protection of overload short circuit and forcircuit change-over in lighting sys tem. Breaking capacity is 3KA. The items comply with IEC60898 standard. Technical parameter: Number of Poles Rated Current (A) Rated Voltage(V) Breaking Capacity(A) Electrical Life(Times) Mechanical Life(Times) 1P,2P,3P 6, 10, 15, 20, 25, 30, 40, 50, 63, 70,80, 90, 100 110/220 (1P), 240/415 (2P), 415(3P) 3000 6000 16000 Dimension(mm): 75 50 25 95 3P 2P 1P 77 64 100 BH-P Miniature Circuit Breaker Applications: BH-P series miniature circuit breaker applies to industrial, commerical, lighting and electric machine distrib ution system with AC415V, 50/60Hz, ratedworking currentup to100Ato protect against overload and short circuit.The itemis installed intoplug-in type mounting base. Technical parameter: Number of Poles Rated Current (A) Rated Voltage(V) Breaking Capacity(A) Electrical Life(Times) Mechanical Life(Times) 1P,2P,3P 6, 10, 15, 20, 25, 30, 40, 50, 63, 70,80, 90, 100 110/220 (1P), 240/415 (2P), 415(3P) 3000 6000 16000 Dimension(mm): 25 20.7 30 ON SOFAB 57.4 75 89 77 64.2 61 75 57.4 www.meba.net Miniature Circuit Breaker BH 09 BH-P 3. www.mebamfg.com Miniature Circuit Breaker MBGLD4/MBGLD4A Miniature Circuit Breaker Specification needs: Electrical Properties Type of Assembly Features Present Certificates Testing For Acceptance Packing Dial Century,Year, Month andBatch Catalog Shows Technical Warranty Place of Delivery Delivery Product Details Manufacturing Standards Tropicalization Manufacturer: Meba Electric Enterprises Country of Origin: China Brand: Meba Model: MBGLD4/ MBGLD4A IEC 60898 IEC60947 Relative Humidity Room Temperature Rated at 40 Rated operating voltage at 40 Nominal Frequency Interrupting Capacity at 230V Operating temperature Degree of Protection Number of poles Conductor cross section (minimum allowable) Minimum number of power moves Minimum number of mechanical operations Operation curve Current Trip Curve Characteristic Intervention FOR RIEL DIN 35 mm MAGNETIC COIL: ensures the switching of short-circuit, speaking within the following ranges: 5 to 10 times rated current ( Type C ), 3 to 5 times rated current ( Type B ), 10 to 14 times rated current ( TypeD ) BIMETAL: ensuresthe breaker trip when overloaded. ARC CHAMBER: effectivelydissipates the electric arc that is generated by the opening contacts of the trigger mechanism in the presence of an overload or short circuit. CE CB ISO9001-2000awarded bythecompetentcertification body, Mebais qualifiedinthemanufacturing ofthe object IEC 60898 standards in the manufacture of the goods Curve compliance issued Shot by an accredited laboratory for effect Life, given by Meba to ensure that the life of the goods offered by atleast 15 years. Before receiving the circuit breakers (breakers), customers may perform the tests may be necessary to ensure compliance with the technical specifications. The packaging is sure that withstand anyadverse conditions duringtransport and handling to the warehouse of customers In one of its sides the breaker is marked with permanent ink, year, month and batch. Attach catalogs indicating the technical specification Submit sample of the product offered 2 YEARS FOB & CNF 25 Days A Vac Hz kA 2 mm A 93% RH at 25 50% RH at 40 -5 a 40 6/10/16/20/25/32/40/50/63 240/415 50/60 6 -5 a 40 IP20 1/2/3/4 25 4000 8000 B/C/D Type B: 3 a 5 In Type C: 5 a10 In Type D: 10 a 14 In attach 10 MBGLD4AMBGLD4 4. MBBH Miniature Circuit Breaker Applications: MBBH series miniature circuit breaker, major export to South America, Middle East market, has light weight, smallsize, novel structure and excellent performance. They are mounted in the metal distribution boar d and used in guesthouses. block of fiats, high buildings, squares, airpo rts, railway stations, plants and enterprises etc, in AC circuits 240V(single pole) up to 415V(3poie) 50Hz for protectionof overload short circuitand for circuitchangeover in lightingsystem. Breaking capacityis 3KA.The items complywith BS&NEMASTANDARD. Specification needs: Electrical Properties Type of Assembly Features Present Certificates Testing For Acceptance Packing Dial Century, Year, Month and Batch Catalog Shows Technical Warranty Place of Delivery Delivery Product Details Manufacturing Standards Tropicalization A Vac Hz kA 2 mm A Manufacturer: Meba Electric Enterprises Country of Origin: China Brand: Meba Model: MBBH IEC60947 Relative Humidity Room Temperature Rated at 40 Rated operating voltage at 40 Nominal Frequency Interrupting Capacity at 230V Operating temperature Degree of Protection Number of poles Conductor cross section (minimum allowable) Minimum number of power moves Minimum number of mechanical operations Operation curve Current Trip Curve Characteristic Intervention NEMA Type MAGNETIC COIL: ensures the switching of short-circuit, speaking within the following ranges: 5 to 10 times rated current (Type C), 10 to 14 times rated current ( Type D) BIMETAL: ensuresthe breaker trip when overloaded. ARC CHAMBER: effectively dissipates the electric arcthat is generatedby the openingcontacts of thetrigger mechanism in the presence of an overload or short circuit. CE ISO 9001-2000 awardedby the competent certification body, Meba is qualifiedin the manufacturingof the object IEC 60947 standards in the manufacture of the goods Curve compliance issued Shot by an accredited laboratory for effect Life, given by Meba to ensure that the life of the goods offered by atleast 15 years. Before receiving thecircuit breakers (breakers),customers may performthe tests maybe necessary toensure compliance with the technical specifications. The packaging is sure that withstand any adverse conditions during transport and handling to the warehouse of customers In one of its sides the breaker is marked with permanent ink, year, month and batch. Attach catalogs indicating the technical specification Submit sample of the product offered 2 YEARS FOB & CNF 25 Days 93% RH at 25 10 a 60 6/10/15/20/30/40/50/60 120/240/415 50/60 3 -5 a +40 IP20 1, 2, 3, 4 25 4000 6000 B/C/D Type B 3 a 5 In Type C 5 a 10 In Type D 10 a 14 In attach www.meba.net Miniature Circuit Breaker 11 MBBH 5. MABD Miniature Circuit Breaker Specification needs: Manufacturer: Meba Electric Enterprises Country of Origin: china Brand: meba Model: MABD IEC 60898 IEC60947-2 Relative Humidity Room Temperature Rated at 40 Rated operating voltage at 40 Nominal Frequency Interrupting Capacity at 230 V Operating temperature Degree of Protection Number of poles Conductor cross section (minimum allowable) Minimum number of power moves Minimum number of mechanical operations Operation curve Current Trip Curve Characteristic Intervention NEMA TYPE MAGNETIC COIL: ensures the switching of short-circuit, speaking within the following ranges: 5 to 10 times rated current (Type C). BIMETAL: ensuresthe breaker trip when overloaded. ARC CHAMBER: effectivelydissipates the electric arc that is generated by the opening contacts of the trigger mechanism in the presence of an overload or short circuit. Semko CB ISO9001-2000, awardedby the competentcertification body, Mebais qualifiedin the manufacturingof the object IEC 60898 standards awarded by an international certifying body. Curve compliance issued Shot by an accredited laboratory for effect Life, given by Meba to ensure that the life of the goods offered by atleast 15 years. Before receivingthe circuit breakers (breakers), customers may perform the tests may be necessary to ensure compliance with the technical specifications. The packaging is sure that withstand any adverse conditions during transport and handling to the warehouse of cutomers. In one of its sides the breaker is marked with the symbol permanent ink, year, month and batch. Attach catalogs indicating the technical specifications Submit sample of the product offered 2 YEARS CNF & FOB 25 DAYS A Vac Hz kA 93% RH at 25 10 a 60 6110/6/20/25/32/40/50/63 120/240/415 50/60 6 40 IP20 1/2/3/4 25 4000 8000 B/C/D 5 a 10 In attach Electrical Properties Type of Assembly Features Present Certificates Testing For Acceptance Packing Dial Century,Year, Month and Batch Catalog Shows Technical Warranty Place of Delivery Delivery Product Details Manufacturing Standards Tropicalization 2 mm A www.meba.net Miniature Circuit Breaker 12 MABD 6. Applications: GV series motor protection circuit breaker are mainl