1006 series electric strike - content.assaabloyusa.com.pdf · 1006 series electric strike 1006...

8
® Installation Instructions 3062006.006, Rev. 1 1006 SERIES ELECTRIC STRIKE 1006 Electric Strike Body Trim Enhancer (with screws) Product Components Electrical Specifications ELECTRICAL RATINGS FOR SOLENOID MINIMUM WIRE GAUGE REQUIREMENTS (One Way) SOLENOID VOLTAGE CONTINUOUS DUTY 12 VDC 12 VDC 25 .48 24 VDC 24 VDC 100 .24 Resistance in Ohms Amps Solenoids are rated at +/- 10% indicated value. 200 feet or less 200 - 300 feet 300 - 400 feet 18 gauge 16 gauge 14 gauge 18 gauge 18 gauge 16 gauge 12 & 24 Volt Pigtails Keeper Shims (2, with screws) 1 2 2 3 4 3 4 1 1

Upload: others

Post on 12-Feb-2020

59 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: 1006 SERIES ELECTRIC STRIKE - content.assaabloyusa.com.pdf · 1006 SERIES ELECTRIC STRIKE 1006 Electric Strike Body Trim Enhancer (with screws) Product Components Electrical Specifications

® Installation Instructions

3062006.006, Rev. 1

1006 SERIES ELECTRIC STRIKE

1006 Electric Strike Body Trim Enhancer (with screws)

Product Components

Electrical SpecificationsELECTRICAL RATINGS FOR SOLENOID MINIMUM WIRE GAUGE REQUIREMENTS (One Way)

SOLENOID VOLTAGECONTINUOUS DUTY 12 VDC 12 VDC25

.48

24 VDC 24 VDC100.24

Resistance in OhmsAmps

Solenoids are rated at +/- 10% indicated value.

200 feet or less

200 - 300 feet

300 - 400 feet

18 gauge

16 gauge

14 gauge

18 gauge

18 gauge

16 gauge

12 & 24 Volt Pigtails Keeper Shims (2, with screws)

1

2

2

3

4

3

4

1

1

Page 2: 1006 SERIES ELECTRIC STRIKE - content.assaabloyusa.com.pdf · 1006 SERIES ELECTRIC STRIKE 1006 Electric Strike Body Trim Enhancer (with screws) Product Components Electrical Specifications

2

Installation Directions

NOTE: Cutout templates are detailed on Page 3 and faceplate options are detailed on Page 4.

4. PREPARE the frame using appropriate lockset template and faceplate combination.

Preparing the Strike

CAUTION! Before connecting any device at the installation site, verify input voltage using a multimeter. Many power supplies and low voltage transformers operate at higher levels than listed. Any input voltage exceeding10% of the solenoid rating may cause severe damage to the unit and will void the warranty.

Preparing the Frame

LBSM WIRING

WhiteOrange Normally OpenGreen Normally Closed

Common BrownBlue Normally Open

Yellow Normally Closed

Common

Diagram 2. 12V to 24V Conversion

BrownBlueYellow

WhiteOrangeGreen

Diagram 3. Latchbolt Monitor Diagram 4. Latchbolt Strike Monitor

BLACK

RED/GREEN

RED

VIOLET

VIOLET

RED/GREEN

BLACK

RED

IF CONNECTOR IS MISSING

(+ 12 VDC)

(-NEG)

(+ 24 VDC)

(-NEG)ELEC

TRIC

ST

RIKE

ELEC

TRIC

ST

RIKE

CONNECT TOGETHER

CONNECT TOGETHER

CONNECT TOGETHER

Finishing the Installation5. ATTACH the electric strike to the jamb using the screws provided with the faceplate option kit.

NOTE: For 12V DC, the pigtail marked “12 VDC” should be used. For 24V DC, the pigtail marked “24 VDC” should be used.

1. SELECT the appropriate Plug In Connector that matches system power and electrically CONNECT as illustrated in Diagram 2.

2. IF no connector is present, THEN CONFIGURE the wires as illustrated in Diagram 2.

3. IF using the Latchbolt Monitor (LBM) or Latchbolt Strike Monitor (LBSM), THEN REFER to Diagrams 3 and 4 to complete wiring.

LBM WIRING

Page 3: 1006 SERIES ELECTRIC STRIKE - content.assaabloyusa.com.pdf · 1006 SERIES ELECTRIC STRIKE 1006 Electric Strike Body Trim Enhancer (with screws) Product Components Electrical Specifications

3

1006 WITH CYLINDRICAL LOCKSETSCutout Templates

1006 WITH CYLINDRICAL LOCKSETS

2X 12-24UNC THREADS

2X 12-24UNC THREADS

1-11/16"

1-1/4"

1-11/16"

1-1/4"

5/32”

1-11/16"

9"

1-3/8"

1006 WITH MORTISE LOCKSETS

Inches [Millimeters]

4-7/8"[123.83]

4-1/8"[104.77]

[85.72]3-3/8"

[42.86]

[31.8]

[42.86]

[85.72]3-3/8"

[31.8]

4-1/8"[104.77]

4-7/8"[123.83]

[85.72]3-3/8"

[42.86]

[34.92]

[228.6]

CL

CL

29/32”[23.01]

19/32”[15.08]

CLStrikePrep

3/8"

4"

8"

1-1/4"

1-3/4"

Vertical Centerline

CLLock

4-7/8"4-1/8"3-1/2"

5/8"

1-1/4"

MortiseLockset

CLStrike

CLStrikePrep

5/8"

1-1/4"

Cylindrical Lock

CL

CLSTRIKE

LOCK

Vertical Centerline

2-1/4"

1-1/4"

1-3/4"

Please note the horizontal centerline of the electric strikein relation to the centerline of the mortise lockset.

Please note the horizontal centerline of the electric strikein relation to the centerline of the cylindrical lockset.

[203.2]

[101.6]

[44.45]

[31.8]

[9.53]

[15.88]

[31.8]

[88.9] [104.77] [123.83] [57.15]

[31.8]

[44.45]

[15.88]

[31.8]

3-1/2"[88.9]

4-1/8"[104.77]

4-7/8"[123.83]

METAL JAMB WOOD JAMB

“LB Latchbolt” “DB Dead Bolt” ”AS Deadbolt Recapture” “-2- Latchbolt or Deadbolt”Cutout dimenstions for option faceplates: Cutout dimenstions for option faceplates: Cutout dimenstions for option faceplates:J, K, KM, N, NM, H, Z, R and E N, KD, ND, HD, HM, and NM J2, K2, KM2, N2, and H2

Note: Normally used with mortise locks without deadbolt. Not used with Schlage L9000 or Yale 8700 series.

Note: Normally used with mortise locks without deadbolt recapture. “AS” option only used with mortise locks with deadbolt with continuous recapture. Can be use with Schlage L9000 or Yale 8700 series

Installation for 1006 Series Complete PACs and Faceplate Options

Page 4: 1006 SERIES ELECTRIC STRIKE - content.assaabloyusa.com.pdf · 1006 SERIES ELECTRIC STRIKE 1006 Electric Strike Body Trim Enhancer (with screws) Product Components Electrical Specifications

4

Complete Pac Options (continued)E

Components

Low Profile Floor

6-32 x 1/4” Screws 6-32 Nuts

# 6 Lock Washers 4-40 x 5/16” Screw

Deadbolt Catcher

1. Remove the 4-40 x 3/16” screws and standard floor from the electric strike as illustrated above.

2. Install the Low Profile Floor using the 4-40 x 5/16” screw provided with the Faceplate Option Kit as illustrated above.

Installation

Page 5: 1006 SERIES ELECTRIC STRIKE - content.assaabloyusa.com.pdf · 1006 SERIES ELECTRIC STRIKE 1006 Electric Strike Body Trim Enhancer (with screws) Product Components Electrical Specifications

5

Complete Pac Options (continued)H, HD, HM, and H2

Components

Deadbolt Bracket

10-32 x 1/8” Screw

# 6 Lock Washers(HT and HTD only)

6-32x 1/4” Screw(HT and HTD only)

Deadlatch Bracket(HT and HTD only)

Installation

1. Install the Deadbolt Bracket using the 10-32 x 1/8”screw as illustrated above. If using an HT or HTD option,proceed to step 2.

2. Install the Deadlatch Bracket using the 6-32 x 1/4”screw and #6 Lock Washer as illustrated above.

Page 6: 1006 SERIES ELECTRIC STRIKE - content.assaabloyusa.com.pdf · 1006 SERIES ELECTRIC STRIKE 1006 Electric Strike Body Trim Enhancer (with screws) Product Components Electrical Specifications

6

Complete Pac Options (continued)R

Components

Installation

# 6 Lock Washers 10-32 x 1/8” Screw 6-32 x 1/4” Screws

Hookbolt CatcherHookbolt Bracket

4-40 x 5/16” Screw

Low Profile Floor

1. Remove the 4-40 x 3/16” screws and standard floor from the electric strike as illustrated above.

2. Install the Low Profile Floor using the 4-40 x 5/16” screw provided with the Faceplate Option Kit as illustrated above.

3. Attach the Hookbolt Catcher to the mounting plate using the 6-32 x 1/4” screws, #6 Lock Washers and the 6-32 nuts as illustrated above.

4. Install the Hookbolt Bracket using the 10-32 x 1/8”screw as illustrated above. If using an HT or HTD option,proceed to step 2.

Page 7: 1006 SERIES ELECTRIC STRIKE - content.assaabloyusa.com.pdf · 1006 SERIES ELECTRIC STRIKE 1006 Electric Strike Body Trim Enhancer (with screws) Product Components Electrical Specifications

7

Faceplate Options Inches [Millimeters]

5/32[3.97]

3-1/8”[79.37]

23/32”[18.26]

3-1/8”[79.37]

7/8”[22.23]

2-7/8”[73.02]

1-9/64”[28.83]

1/8”[3.17]

1-11/32” [34.11]

23/32”[18.22]

1-1/16”[26.72]

29/32”[23.39]

1-11/32” [34.11]

27/32”[21.46] 27/32”

[21.46]

23/32”[18.22]

19/32”[15.46] 1-15/32”

[37.29]

1-3/32”[27.81]

5/16”[7.79]

1-23/32”[43.64]

1-37/64”[40.08]

HD, ND H, N HM, NM

KD K R

KM Z J, E

(4-7/8” x 1-1/4” SQUARE CORNER)

1-15/32”[37.29]

1-25/64”[35.48]

1-3/4”[44.45]

CL = center line of faceplate (2nd line = center line of faceplate opening)

Copyright © 2017, Hanchett Entry Systems, Inc., an ASSAABLOY Group company. All rights reserved. Reproduction inwhole or in part without the express written permission ofHanchett Entry Systems, Inc. is prohibited.

Page 8: 1006 SERIES ELECTRIC STRIKE - content.assaabloyusa.com.pdf · 1006 SERIES ELECTRIC STRIKE 1006 Electric Strike Body Trim Enhancer (with screws) Product Components Electrical Specifications

8

Copyright © 2017, Hanchett Entry Systems, Inc., an ASSAABLOY Group company. All rights reserved. Reproduction inwhole or in part without the express written permission ofHanchett Entry Systems, Inc. is prohibited.

®

HES, Inc.Phoenix, AZ 85044800-626-7590www.hesinnovations.com