07/000 t rotary switches, p switch-disconnectors · moeller hpl0211-2001/2002 t rotary switches, p...

85
Moeller HPL0211-2001/2002 T Rotary Switches, P Switch-Disconnectors Rotary Switches Switch-Disconnectors 07/000

Upload: phamnhan

Post on 11-Apr-2018

248 views

Category:

Documents


3 download

TRANSCRIPT

Page 1: 07/000 T Rotary Switches, P Switch-Disconnectors · Moeller HPL0211-2001/2002 T Rotary Switches, P Switch-Disconnectors Overview of Functions Rotary Switches Switch-Disconnectors

Moeller HPL0211-2001/2002

T Rotary Switches, P Switch-Disconnectors

Rota

ry S

witc

hes

Swit

ch-D

isco

nnec

tors

07/000

Page 2: 07/000 T Rotary Switches, P Switch-Disconnectors · Moeller HPL0211-2001/2002 T Rotary Switches, P Switch-Disconnectors Overview of Functions Rotary Switches Switch-Disconnectors

07/001Moeller HPL0211-2001/2002

T Rotary Switches, P Switch-DisconnectorsOverview

Rota

ry S

wit

ches

Swit

ch-D

isco

nnec

tors

T rotary switches, P switch-disconnectors TM mini rotary switches

Page PageOverview of functions 07/002 Overview of functions 07/002

Technical overview 07/004 Technical overview 07/004

System overview 07/006 System overview 07/072

Key to type references, modular system 07/010 Key to type references, modular system 07/010

On-Off switches On-Off switchesMain switches 07/012 Control circuit isolators 07/074On-Off switches 07/018 On-Off switches 07/074Safety switches 07/024

Control switches Control switchesChangeover switches 07/026 Changeover switches 07/075Reversing switches 07/032 Reversing switches 07/082Star-delta switches 07/032 Step switches 07/077Multi-speed switches 07/034 On-Off switches 07/081Step switches 07/036 Hand/Auto switches 07/076On-Off switches 07/040 On-Off switches, spring-return 07/081Hand/Auto switches 07/042 Coding switches 07/082On-Off switches, spring-return 07/044 Group switches 07/080Universal control switches 07/046Coding switches 07/046Series switches 07/046Instrument selector switches 07/048

Switches with locking arrangementsPanic switches 07/050On-Off switches 07/050Hand/Auto switches 07/052

Accessories AccessoriesFront plates 07/054 Key operation 07/083Key operation 07/058Additional accessories 07/060

Non-standard switches Non-standard switchesT0 rotary switches 07/084 TM mini rotary switches 07/088T3 rotary switches 07/085T5B rotary switches 07/086T5 rotary switches 07/087Bulk packaged switches 07/088

Technical data 07/090 Technical data 07/095

Dimensions 07/096 Dimensions 07/108

Ordering of non-standard switches 07/110 Ordering of non-standard switches 07/110

For other standard contact sequences, see catalogue K115

Page 3: 07/000 T Rotary Switches, P Switch-Disconnectors · Moeller HPL0211-2001/2002 T Rotary Switches, P Switch-Disconnectors Overview of Functions Rotary Switches Switch-Disconnectors

Moeller HPL0211-2001/2002

T Rotary Switches, P Switch-DisconnectorsOverview of Functions

Rota

ry S

witc

hes

Swit

ch-D

isco

nnec

tors

07/002

Function Flush mounting .../E...

Centre mounting.../EZ...

Surface mounting.../I...

Distribution board mounting.../IVS...

Rear mounting.../Z...

On-Off switchesMain switchesMaintenance switchesFor use as Emergency-Stop devices1)

a 07/012

a 07/013

a 07/013

Main switchesMaintenance switcheswith auxiliary contactsFor use as Emergency-Stop devices1)

a 07/014

a 07/015

a 07/015

Main switches Maintenance switches

a 07/013

a 07/013

a 07/013

Main switchesMaintenance switches with auxiliary contacts

a 07/015

a 07/015

a 07/015

On-Off switches with black thumb-grip

a 07/016

a 07/019

a 07/019

a 07/019

a 07/019

a 07/074

a 07/074

On-Off switches with black thumb-gripWith auxiliary contacts

a 07/020

a 07/021

a 07/021

a 07/021

a 07/021

On-Off switchesFor use as Emergency-Stop devices1)

a 07/022

a 07/023

a 07/023

Control circuit isolators

a 07/074

Safety switches 25 – 100 AFor use as Emergency-Stop devices1)

a 07/024

Safety switches 25 – 100 A

a 07/025

Notes 1) To IEC/EN 60 204-1;With red thumb-grip and yellow front plate

Page 4: 07/000 T Rotary Switches, P Switch-Disconnectors · Moeller HPL0211-2001/2002 T Rotary Switches, P Switch-Disconnectors Overview of Functions Rotary Switches Switch-Disconnectors

Rota

ry S

wit

ches

Swit

ch-D

isco

nnec

tors

07/003Moeller HPL0211-2001/2002

T Rotary Switches, P Switch-DisconnectorsOverview of Functions

Function Flush mounting .../E...

Centre mounting.../EZ...

Surface mounting.../I...

Distribution board mounting.../IVS...

Rear mounting.../Z...

Control switchesChangeover switchesMains transfer-, group switches

a 07/026

a 07/027

a 07/027

a 07/027

a 07/027

a 07/075

a 07/075

Reversing switches

a 07/032

a 07/033

a 07/033

a 07/033

a 07/033

a 07/082

a 07/082

Star-delta switches

a 07/032

a 07/033

a 07/033

a 07/033

a 07/033

Multi-speed switches

a 07/034

a 07/035

a 07/035

a 07/035

a 07/035

Step switches

a 07/036

a 07/036

a 07/037

a 07/037

a 07/037

a 07/077

a 07/077

On-Off switches, changeover switches

a 07/040

a 07/040

a 07/041

a 07/041

a 07/041

a 07/081

a 07/081

Hand/Auto switches

a 07/042

a 07/042

a 07/043

a 07/043

a 07/043

a 07/076

a 07/076

Spring-return switches

a 07/044

a 07/044

a 07/045

a 07/045

a 07/045

a 07/081

a 07/081

Universal control switches

a 07/046

a 07/046

a 07/047

a 07/047

a 07/047

Coding switches

a 07/046

a 07/046

a 07/047

a 07/047

a 07/047

a 07/082

a 07/082

Series switches

a 07/046

a 07/046

a 07/047

a 07/047

a 07/047

Instrument selector switches(voltage)

a 07/048

a 07/048

a 07/049

a 07/049

a 07/049

Instrument selector switches(current)

a 07/048

a 07/048

a 07/049

a 07/049

a 07/049

Switches with locking arrangements

a 07/050

a 07/051

a 07/051

Page 5: 07/000 T Rotary Switches, P Switch-Disconnectors · Moeller HPL0211-2001/2002 T Rotary Switches, P Switch-Disconnectors Overview of Functions Rotary Switches Switch-Disconnectors

Moeller HPL0211-2001/2002

T Rotary Switches, P Switch-DisconnectorsTechnical Overview

Rota

ry S

witc

hes

Swit

ch-D

isco

nnec

tors

07/004

Switch sizeTM T0 T3 T5B

Three-phase motor rating AC-3 220 – 240 V kW 1.5 3 6.5 15380 – 440 V kW 2.2 4 12 22690 V kW – 4 15 22

AC-23 220 – 240 V kW 1.8 3.5 7.5 18.5380 – 440 V kW 3 6.5 13 22690 V kW – – – 22

Rated operational current AC-21 380 – 440 V 3~ A 10 20 32 63AC-15 220 – 240 V A 2.5 6 10 16

380 – 415 V A 1.5 4 6 6Rated uninterrupted current A 10 20 32 63

Mounting formType Degree of protection

Surface mounting1)

.../I... IP65 –

K

K

K

.../I 45/... – – – –

.../I 48/... – – – –

.../ST/... –

K

K

K

Surface mounting main switch1)

.../I.../SVB... IP65 –

K

K

K

.../ST/SVB... –

K

K

K

Flush mounting.../E... Front IP65

K

K

K

K

Flush mounting main switch/flush mounting control circuit isolator

.../EA/SVB... Front IP65 –

K

K

K

TM.../E/SVB

K – – –

Centre mounting.../EZ... Front IP65 –

K

K –TM.../EZ

K – – –

Rear mounting.../Z... Front IP65 –

K

K

K

Rear mounting main switches.../V/SVB... Front IP65 –

K

K

K

Service distribution board mounting.../IVS... Front IP30

K

K – –

Notes 1) Enclosures for metric cable glands to EN 50 262, cable glands

a Page 07/070

Page 6: 07/000 T Rotary Switches, P Switch-Disconnectors · Moeller HPL0211-2001/2002 T Rotary Switches, P Switch-Disconnectors Overview of Functions Rotary Switches Switch-Disconnectors

Rota

ry S

wit

ches

Swit

ch-D

isco

nnec

tors

07/005Moeller HPL0211-2001/2002

T Rotary Switches, P Switch-DisconnectorsTechnical Overview

T5 T6-2 T6-3-8212 T6-160-6 T8-3-8342 T8-3-8212 P1 P318.5 22 22 22 37 37 5.5 7.5 15 2230 37 37 45 55 55 7.5 13 30 3730 22 22 22 37 37 7.5 15 30 37

18.5 37 37 37 75 75 7 8.5 18.5 3030 45 45 55 132 132 13 15 37 5030 30 30 30 37 37 11 18.5 30 75

100 125 125 160 315 315 25 32 63 10016 – – – – – – – – –6 – – – – – – – – –100 125 125 160 315 315 25 32 63 100

K – – – – –

K

K

– – –

K – – – –– – – –

K – – –

K – – – – –

K

K

K – – – – –

K

K

K – – – – –

K

K

K

K

K – –

K

K

K

K

K – – – –

K

K

– – – – – – – –

– – – – – –

K –– – – – – – – –

� – – – – –

K

K

K

K –

K

K –

K

K

– – – – – –

K

K

Page 7: 07/000 T Rotary Switches, P Switch-Disconnectors · Moeller HPL0211-2001/2002 T Rotary Switches, P Switch-Disconnectors Overview of Functions Rotary Switches Switch-Disconnectors

Moeller HPL0211-2001/2002

T Rotary SwitchesSystem Overview

Rota

ry S

witc

hes

Swit

ch-D

isco

nnec

tors

07/006

T0, T3, T5B, T5 On-Off switches

T0, T3, T5B, T5 control switches

10

9

8

7

7

6

5

4

3

2

1

6

8

9

10

10

1

2

3

4

99

10

Page 8: 07/000 T Rotary Switches, P Switch-Disconnectors · Moeller HPL0211-2001/2002 T Rotary Switches, P Switch-Disconnectors Overview of Functions Rotary Switches Switch-Disconnectors

Rota

ry S

wit

ches

Swit

ch-D

isco

nnec

tors

07/007Moeller HPL0211-2001/2002

T Rotary SwitchesSystem Overview

Service distribution board mounting (.../IVS)

1

Front IP30For snap fitting to EN 50 022 top-hat railFlush mounting– service distribution boards: up to

3 contact units (45 mm mounting depth)– control panels: up to 11 contact units

a Page 07/019

Rear mounting (.../Z) 2Front IP65Secured by screw fixing or snap fitting(T0 or T3)For snap fitting to EN 50 022 top-hat railCoupling drive in door or coverConnection from the front

a Page 07/019

Rear mounting main switches(.../V/SVB)

2

Front IP65To IEC/EN 60 204and IEC/EN 60 947-3,up to 8 contacts for T0..., and up to 12contacts for T3With door interlock in I (On) position

a Page 07/013

Flush mounting (.../E) 3Front IP65Fitting and connection from the rearTerminal:Pozidriv plus-minus screwFinger and back-of-hand proofType T8 with extension terminals as standard

a Page 07/018

Flush mounting main switches (.../EA/SVB)

3

Front IP65To IEC/EN 60 204and IEC/EN 60 947-3,up to 8 contacts for T0..., and up to 12contacts for T3N terminal and PE terminal

a Page 07/012

Centre mounting (.../EZ) 3Front IP65Mounting in ∅ 22.3 fixing hole to IEC/EN 60 947-5-1Centre fixing permits installation by one fitter

a Page 07/019

Surface mounting (.../I...) 4IP65 With PE terminalEnclosures designed for metric cable glands to EN 50 262

a Page 07/019

Surface mounting main switches(.../I...)

4

IP65 To IEC/EN 60 204and IEC/EN 60 947-3,up to 8 contacts for T0..., and up to 10contacts for T30 (Off) position lockable using up to 3 padlocksEnclosures designed for metric cable glands to EN 50 262With PE terminal

a Page 07/013

Safety switches (.../I...) 5IP65 With PE terminalWith cover fixing in the 0 (Off) position0 (Off) position lockable using up to 3 padlocksEnclosures designed for metric cable glands to EN 50 262With “Safety Switch” labelColour: orangeFor Switzerland: comply with the Swiss Accident Insurance Institute Directive

a Page 07/024

Main switch (assembly kit)for use as Emergency-Stop device

6

To IEC/EN 60 204-1

With red rotary handle and yellow locking collar

Lockable in the 0 (Off) position

a Page 07/062

Main switch (assembly kit) 7Black rotary handle and locking collarLockable in the 0 (Off) position

a Page 07/062

Thumb-grip for use in Emergency-Stop devices

8

To IEC/EN 60 204-1

Red thumb-grip with yellow front plate

a Page 07/062

Thumb-grip 9Black thumb-grip with front plate

a Page 07/062

Coupling drive 10Includes push-fit shaft For retrofitting T0(T3)-.../XZ basic switchesin the rear mounting form Spare parts for T0(T3)/(P1)-.../ZFor retrofit conversion of T5(B)-.../Eflush mounting switches to rear mounting form Spare part for T5(B)-.../Z

a Page 07/066

Page 9: 07/000 T Rotary Switches, P Switch-Disconnectors · Moeller HPL0211-2001/2002 T Rotary Switches, P Switch-Disconnectors Overview of Functions Rotary Switches Switch-Disconnectors

Moeller HPL0211-2001/2002

P Switch-DisconnectorsSystem Overview

Rota

ry S

witc

hes

Swit

ch-D

isco

nnec

tors

07/008

P1, P3 On-Off switches

11

10

10

9

9

8

7

7

5

3

2

1

4

41

68

11

Page 10: 07/000 T Rotary Switches, P Switch-Disconnectors · Moeller HPL0211-2001/2002 T Rotary Switches, P Switch-Disconnectors Overview of Functions Rotary Switches Switch-Disconnectors

Rota

ry S

wit

ches

Swit

ch-D

isco

nnec

tors

07/009Moeller HPL0211-2001/2002

P Switch-DisconnectorsSystem Overview

Service distribution board mounting (.../IVS)

1

Front IP30Fitting dimensions to DIN 43 880For snap fitting to EN 50 022 top-hat railSpace requirement P1, 3-pole: 3 space unitsP3, 3-pole: 4 space unitsP3-.../IVS can be locked in 0 (Off) position using the padlocking feature

a Page 07/019

Rear mounting (.../Z) 2Front IP65Secured by snap fitting or screw fixing

For snap fitting to EN 50 022 top-hat railCoupling drive in door or coverConnection from the front2 add-on modules can be fitted (or retrofitted)

a Page 07/019

Rear mounting main switches(.../V/SVB)

2

Front IP65To IEC/EN 60 204 andIEC/EN 60 947-3With door interlock in I (On) position Maintenance key for commissioning or fault tracing 0 (Off) position lockable using up to 3 padlocks 2 add-on modules can be fitted (or retrofitted)

a Page 07/013

Flush mounting (.../E) 3Front IP65Fitting and connection from the rearTerminal:Pozidriv plus-minus screwFinger and back-of-hand proof2 add-on modules can be fitted (or retrofitted)

a Page 07/018

Flush mounting main switches (.../EA/SVB)

3

Front IP65To IEC/EN 60 204 andIEC/EN 60 947-3N terminal and PE terminal0 (Off) position lockable using up to 3 padlocks 2 add-on modules can be fitted (or retrofitted)

a Page 07/012

Centre mounting (.../EZ) 3Front IP65Mounting in ∅ 22.3 fixing hole to IEC/EN 60 947-5-1Centre fixing permits installation by one fitter

a Page 07/019

Add-on modules 4Switched neutral(early-make contact)HI 11 auxiliary contact = 1 make contact + 1 break contact

Finger-proofAuxiliary make contact: always connected as load-shedding contact (late-make, early-break)

a Page 07/064

Surface mounting (.../I...) 5IP65 With PE terminalAdd-on modules for retrofitting:P1: + 1, P3: + 2Enclosures designed for metric cable glands to EN 50 262

a Page 07/019

Surface mounting main switches(.../I...)

5

IP65 With PE terminalTo IEC/EN 60 204 andIEC/EN 60 947-30 (Off) position lockable using up to 3 padlocksAdd-on modules for retrofitting: P1: + 1, P3: + 2Enclosures designed for metric cable glands to EN 50 262

a Page 07/013

Safety switches (.../I...-SI) 6IP65 With PE terminalWith cover fixing in the 0 (Off) position0 (Off) position lockable using up to 3 padlocksWith “Safety Switch” labelColour: orangeEnclosures designed for metric cable glands to EN 50 262For Switzerland: comply with the Swiss Accident Insurance Institute Directive

a Page 07/024

Main switch (assembly kit)for use as Emergency-Stop device

7

To IEC/EN 60 204-1With red rotary handle and yellow locking collarLockable in the 0 (Off) position

a Page 07/062

Main switch (assembly kit) 8Black rotary handle and locking collarLockable in the 0 (Off) position

a Page 07/062

Thumb-grip for use in Emergency-Stop devices

9

To IEC/EN 60 204-1Red thumb-grip with yellow front plate

a Page 07/062

Thumb-grip 10Black thumb-grip with front plate

a Page 07/062

Coupling drive 11Includes push-fit shaft For retrofitting T0(T3)-.../XZ basic switchesin the rear mounting form Spare parts for T0(T3)/(P1)-.../ZFor retrofit conversion of T5(B)-.../Eflush mounting switches to rear mounting form Spare part for T5(B)-.../Z

a Page 07/066

Page 11: 07/000 T Rotary Switches, P Switch-Disconnectors · Moeller HPL0211-2001/2002 T Rotary Switches, P Switch-Disconnectors Overview of Functions Rotary Switches Switch-Disconnectors

Moeller HPL0211-2001/2002

T Rotary Switches, P Switch-DisconnectorsKey to Type References, Modular System

Rota

ry S

witc

hes

Swit

ch-D

isco

nnec

tors

07/010

Using the modular system to convert the mounting form

Using the modular system to convert the mounting form of T5(B)

Rotary switches are suitable for many different switching and control functions, e.g. as On-Off switches, main switches, main circuit/auxiliary circuit control switches, instrument selector switches.

The switches consist of a handle, basic switch and mounting accessories.

The contact chamber (contact unit) contains1 or 2 contacts.

Our “T Rotary Switches” catalogue, K115, shows more than 800 often used standard contact sequences (available on request).

On the following Pages, you will find a selection of the standard contact sequences we offer.

T rotary switches and P switch-disconnectors are manufactured without PCB, CFC, asbestos or silicon. The contacts are cadmium-free.

The CI-K insulated enclosures do not contain silicon

Technical Data for CI-K small enclosures:

a See Instal-lation Equipment Catalogue, HPL0212-2000GB

T0 and T3 rotary switches

Key to type references

T . . . . . . . . . . . . - . . . . . . . . . . . . . . . . . . . . . . . . . . . . - . . . . . . . . . . . . . . . . . . . . . . . / . . . . . . . . . . . . . . . . . . . . + . . . . . . . . . . . . . . . . . . + . . . . . . . . . . . . . . . . . .↑ ↑ ↑ ↑ ↑ ↑

Switch sizeT0 or T3

Number of contact chambers = contact units

Contact sequence number

Mounting form

a Page 07/004Front plate Type(if different from list Type)

a Page 07/054

Accessories

a Page 07/056

T5(B) rotary switches

Key to type references

T . . . . . . . . . . . . - . . . . . . . . . . . . . . . . . . . . . . . . . . . . - . . . . . . . . . . . . . . . . . . . . . . . / . . . . . . . . . . . . . . . . . . . . + . . . . . . . . . . . . . . . . . . + . . . . . . . . . . . . . . . . . .↑ ↑ ↑ ↑ ↑ ↑

Switch sizeT5(B)

Number of contact chambers = contact units

Contact sequence number

Mounting form

a Page 07/004Front plate Type(if different from list Type)

a Page 07/054

Accessories

a Page 07/054

Notes Types preceded by “+...” are additions to thebasic Type and cannot be ordered separately.

1) Includes shaft

CI-K1-T0CI-K2-T3

T0-.../I11)

T3-.../I21)T0.../IVS1)

T0(3).../E

T0(3).../EZ

EZ-T0 V/EA/SVB-T0 T0(3).../XZ IVS-T0 DE-T0

T0(3).../Z1)

V/EA/SVB-T0

T0-1-(T3-1-).../V/SVB...T0-4-(T3-1-).../V/SVB

T0-1-(T3-1-).../EA/SVB...T0-4-(T3-6-).../EA/SVB

CI-K4-T5BCI-K5-T5

DE-P3V/EA/SVB-T5T5(B)...E

T5(B).../EA/SVB T5(B).../Z

V/EA/SVB-T5

T5(B).../V/SVB

T5B-.../I4T5-.../I5

SVB-P3

T5B-.../I4/SVBT5-.../I5/SVB

Page 12: 07/000 T Rotary Switches, P Switch-Disconnectors · Moeller HPL0211-2001/2002 T Rotary Switches, P Switch-Disconnectors Overview of Functions Rotary Switches Switch-Disconnectors

Rota

ry S

wit

ches

Swit

ch-D

isco

nnec

tors

07/011Moeller HPL0211-2001/2002

T Rotary Switches, P Switch-DisconnectorsKey to Type References, Modular System

The modular system offers add-on functions

P1 and P3 switch-disconnectors

Key to type references

P . . . . . . . . . . . . - . . . . . . . . . . . . . . . . . . . . . . . . . . . . / . . . . . . . . . . . . . . . . . . . . - . . . . . . . . . . . . . . . . . . / . . . . . . . . . . . . . . . . . .↑ ↑ ↑ ↑ ↑

Switch sizeP1 or P3

Rated uninterrupted current Mounting form

a Page 07/005Type suffix(if required)

Accessories

a Page 07/056

TM mini rotary switchesThe TM rotary switch requires very little space due to its exceptionally small dimensions. It is particularly well suited for switching the low voltages and low currents which occur in electronic control panels, for example. The gold-plated contacts provide extra reli-ability and safety.

TM mini rotary switches have consecutive terminal markings, beginning with 1.

Key to type references

TM-. . . . . . . . . . . . . . . . . . . . . . . . . - . . . . . . . . . . . . . . . . . . . . . . . / . . . . . . . . . . . . . . . . . . . . + . . . . . . . . . . . . . . . . . .↑ ↑ ↑ ↑

Number of contact chambers = contact units

Contact sequence number

Mounting form

a Page 07/074Accessories

a Page 07/083

Circuit diagrams

on Pages 07/012 – 053 and 07/074 – 082

Example:

(see also Ordering Example on Page 07/111)Switch position 1:Contact 1 – 2 open,Contact 3 – 4 closed.

Switching from 1 to 2:Contact 1 – 2 closes with early make,Contact 3 – 4 opens with late break.

Switching from 2 to 3:Contact 1 – 2 opens briefly.

Switching from 3 to 4:Contact 1 – 2 remains closed,Automatic return from 4 to 3.

N-P...E orN-P...Z

HI 11-P1/P3E orHI 11-P1/P3Z

3-pole basic unit.../E oder .../Z

Switched neutralCan be fitted left or right(for P1.../I: left only)

Auxiliary contactCan be fitted leftor right(for P1.../I: left only)

Terminal shroudcan be fitted attop and bottom

N + PE terminals alsoas cover interlockon .../Z-switches.

H-P... UV-P...

1

2

3

4Terminal marking

Link

1

2

3

4

0

1

2

Contact open

Contact closed

Switch position

0

1

2

3

4

Page 13: 07/000 T Rotary Switches, P Switch-Disconnectors · Moeller HPL0211-2001/2002 T Rotary Switches, P Switch-Disconnectors Overview of Functions Rotary Switches Switch-Disconnectors

Moeller HPL0211-2001/2002

T Rotary Switches, P Switch-DisconnectorsMain Switches, Maintenance Switches

Rota

ry S

witc

hes

Swit

ch-D

isco

nnec

tors

Rota

ry S

wit

ches

Swit

ch-D

isco

nnec

tors

Moeller HPL0211-2001/2002

T Rotary Switches, P Switch-DisconnectorsMain Switches, Maintenance Switches

For use as Emergency-Stop device1) Without Emergency-Stop function2)

Circuit diagram Front plate no.

Main contacts

Auxiliary contacts

Max. three-phasemotor rating (per set of 3 contacts)50–60 Hz

Rated uninter-rupted current

Flush mountingFront IP65

Surface mounting 3)

IP65

Rear mountingFront IP65

Flush mountingFront IP65

Surface mounting 3) IP65

Rear mountingFront IP65

No. of poles AC-3

220 V230 V240 V

380 V400 V440 V

660 V690 V

Iu

Basic typeFor ... insert mounting form

Mounting formArticle no.

PriceSee Price List

Mounting formArticle no.

PriceSee Price List

Mounting formArticle no.

PriceSee Price List

Mounting formArticle no.

PriceSee Price List

Mounting formArticle no.

PriceSee Price List

Mounting formArticle no.

PriceSee Price ListM M B kW kW kW A

Main switches1 0 0 1 1.3 – 20 T0-1-8200/... EA/SVB

053110I1/SVB207145

V/SVB057856

EA/SVB-SW055483

I1/SVB-SW207146

V/SVB-SW060229

1.8 3.6 – 32 T3-1-8200/... EA/SVB066576

I2/SVB207200

V/SVB007255

EA/SVB-SW068949

I2/SVB-SW207201

V/SVB-SW004882

5 7.3 – 63 T5B-1-8200/... EA/SVB094279

I4/SVB207240

V/SVB094273

EA/SVB-SW094278

I4/SVB-SW207241

V/SVB-SW094272

7.3 12.3 – 100 T5-1-8200/... EA/SVB097224

I5/SVB207275

V/SVB097222

EA/SVB-SW097223

I5/SVB-SW207276

V/SVB-SW097221

2 0 0 2.2 2.2 – 20 T0-1-102/... EA/SVB091078

I1/SVB207143

V/SVB095824

EA/SVB-SW093451

I1/SVB-SW207144

V/SVB-SW022330

3 5.5 – 32 T3-1-102/... EA/SVB014374

I2/SVB207198

V/SVB019120

EA/SVB-SW016747

I2/SVB-SW207199

V/SVB-SW021493

7.5 11 – 63 T5B-1-102/... EA/SVB094469

I4/SVB207238

V/SVB094463

EA/SVB-SW094468

I4/SVB-SW207239

V/SVB-SW094462

11 18.5 – 100 T5-1-102/... EA/SVB098808

I5/SVB207273

V/SVB098806

EA/SVB-SW098807

I5/SVB-SW207274

V/SVB-SW098805

3 0 0 3 4 4 20 T0-2-1/... EA/SVB038873

I1/SVB207147

V/SVB043619

EA/SVB-SW041246

I1/SVB-SW207148

V/SVB-SW045992

5.5 7.5 7.5 25 P1-25/... EA/SVB041097

I2/SVB207293

V/SVB055335

EA/SVB-SW048365

I2/SVB-SW207294

V/SVB-SW050738

7.5 13 15 32 P1-32/... EA/SVB081438

I2/SVB207314

V/SVB095676

EA/SVB-SW053111

I2/SVB-SW207315

V/SVB-SW055484

15 30 30 63 P3-63/... EA/SVB031607

I4/SVB207343

V/SVB048218

EA/SVB-SW057857

I4/SVB-SW207344

V/SVB-SW060230

22 37 37 100 P3-100/... EA/SVB074320

I5/SVB207373

V/SVB088558

EA/SVB-SW062603

I5/SVB-SW207374

V/SVB-SW064976

22 37 22 125 T6-2/... EA/SVB012679

– V/SVB015052

EA/SVB-SW067349

– V/SVB-SW069722

3+N 0 0 3 4 4 20 T0-2-8900/... EA/SVB207400

I1/SVB207151

V/SVB207405

EA/SVB-SW207401

I1/SVB-SW207152

V/SVB-SW207406

5.5 7.5 7.5 25 P1-25/... EA/SVB/N081587

I2/SVB/N207298

V/SVB/N086333

EA/SVB-SW/N083960

I2/SVB-SW/N207296

V/SVB-SW/N088706

7.5 13 15 32 P1-32/... EA/SVB/N091079

I2/SVB/N207319

V/SVB/N095825

EA/SVB-SW/N093452

I2/SVB-SW/N207317

V/SVB-SW/N098198

15 30 30 63 P3-63/... EA/SVB/N010398

I4/SVB/N207349

V/SVB/N015144

EA/SVB-SW/N012771

I4/SVB-SW/N207346

V/SVB-SW/N017517

22 37 37 100 P3-100/... EA/SVB/N019890

I5/SVB/N207379

V/SVB/N024636

EA/SVB-SW/N022263

I5/SVB-SW/N207376

V/SVB-SW/N027009

6 0 0 3 4 4 20 T0-3-8342/... EA/SVB029382

I1/SVB207159

V/SVB034128

EA/SVB-SW031755

I1/SVB-SW207160

V/SVB-SW036501

6.5 12 15 32 T3-3-8342/... EA/SVB071326

I2/SVB207208

V/SVB076072

EA/SVB-SW073699

I2/SVB-SW207209

V/SVB-SW078445

15 22 22 63 T5B-3-8342/... EA/SVB092308

I4/SVB207242

V/SVB092300

EA/SVB-SW092307

I4/SVB-SW207243

V/SVB-SW092299

18.5 30 30 100 T5-3-8342/... EA/SVB096383

I5/SVB207279

V/SVB096381

EA/SVB-SW096382

I5/SVB-SW207280

V/SVB-SW096380

8 0 0 3 4 4 20 T0-4-8344/... EA/SVB008267

I1/SVB207163

V/SVB014007

EA/SVB-SW008268

I1/SVB-SW207164

V/SVB-SW008272

6.5 12 15 32 T3-4-8344/... EA/SVB008964

I2/SVB207212

V/SVB020598

EA/SVB-SW008965

I2/SVB-SW207213

V/SVB-SW008967

15 22 22 63 T5B-4-8344/... EA/SVB092062

I4/SVB207248

V/SVB092056

EA/SVB-SW092061

I4/SVB-SW207249

V/SVB-SW092055

22 30 30 1004) T5-4-8344/... EA/SVB095961

I5/SVB207283

V/SVB095959

EA/SVB-SW095960

I5/SVB-SW207284

V/SVB-SW095958

Standard pack: 1 off Standard pack: 1 off

Notes 1) To IEC/EN 60 204-1; with red rotary handle and yellow locking collar, lockable in 0 (Off) position2) With black rotary handle and locking collar, lockable in 0 (Off) position3) Enclosure designed for metric cable glands to EN 50 262, cable glands

a Page 07/070

4) T5-4-8344/I5... max. 95 A

FS 908

ON

OFF

1

2

1

2

3

4

1 3 5

2 4 6

2

1 3

4

5

6

7

8

2

1 3

4

5

6

N

N

2

1 3

4

5

6

7

8

9

10 12

11

2

1 3

4

5

6

7

8

9

10 12

11 13

14 16

15

07/012 07/013

Page 14: 07/000 T Rotary Switches, P Switch-Disconnectors · Moeller HPL0211-2001/2002 T Rotary Switches, P Switch-Disconnectors Overview of Functions Rotary Switches Switch-Disconnectors

Moeller HPL0211-2001/2002

T Rotary Switches, P Switch-DisconnectorsMain Switches with Auxiliary Contacts, Maintenance Switches

Rota

ry S

witc

hes

Swit

ch-D

isco

nnec

tors

Rota

ry S

wit

ches

Swit

ch-D

isco

nnec

tors

Moeller HPL0211-2001/2002

T Rotary Switches, P Switch-DisconnectorsMain Switches with Auxiliary Contacts, Maintenance Switches

For use as Emergency-Stop device1) Without Emergency-Stop function2)

Circuit diagram Front plate no.

Main contacts

Auxiliary contacts

Max. three-phasemotor rating (per set of 3 contacts)50–60 Hz

Rated uninter-rupted current

Flush mountingFront IP65

Surface mounting 4) IP65

Rear mountingFront IP65

Flush mountingFront IP65

Surface mounting 4) IP65

Rear mountingFront IP65

No. of poles AC-3

220 V230 V240 V

380 V400 V440 V

660 V690 V

Iu

Basic typeFor ... insert mounting form

Mounting formArticle no.

PriceSee Price List

Mounting formArticle no.

PriceSee Price List

Mounting formArticle no.

PriceSee Price List

Mounting formArticle no.

PriceSee Price List

Mounting formArticle no.

PriceSee Price List

Mounting formArticle no.

PriceSee Price ListM M B kW kW kW A

Main switches with auxiliary contacts3 1 0 3 4 4 20 T0-2-15679/... EA/SVB

081588I1/SVB207149

V/SVB086334

EA/SVB-SW083961

I1/SVB-SW207150

V/SVB-SW088707

3 1 1 5.5 7.5 7.5 25 P1-25/... EA/SVB/HI11091080

I2/SVB/HI11207297

V/SVB/HI11095826

EA/SVB-SW/HI11070194

I2/SVB-SW/HI11207295

V/SVB-SW/HI11098199

7.5 13 15 32 P1-32/... EA/SVB/HI11072567

I2/SVB/HI11207318

V/SVB/HI11015145

EA/SVB-SW/HI11012772

I2/SVB-SW/HI11207316

V/SVB-SW/HI11017518

15 30 30 63 P3-63/... EA/SVB/HI11019891

I4/SVB/HI11207348

V/SVB/HI11024637

EA/SVB-SW/HI11022264

I4/SVB-SW/HI11207345

V/SVB-SW/HI11027010

22 37 37 100 P3-100/... EA/SVB/HI11029383

I5/SVB/HI11207378

V/SVB/HI11034129

EA/SVB-SW/HI11031756

I5/SVB-SW/HI11207375

V/SVB-SW/HI11036502

3 2 1 3 4 4 20 T0-3-15683/... EA/SVB015571

I1/SVB207157

V/SVB015634

EA/SVB-SW015600

I1/SVB-SW207158

V/SVB-SW015664

6.5 12 15 32 T3-3-15683/... EA/SVB040478

I2/SVB207206

V/SVB045224

EA/SVB-SW042851

I2/SVB-SW207207

V/SVB-SW047597

3+N 1 1 3 4 4 20 T0-3-15680/... EA/SVB038875

I1/SVB207153

V/SVB043621

EA/SVB-SW041248

I1/SVB-SW207154

V/SVB-SW045994

6.5 12 15 32 T3-3-15680/... EA/SVB012002

I2/SVB207202

V/SVB016748

EA/SVB-SW014375

I2/SVB-SW207203

V/SVB-SW019121

3+N 1 1 5.5 7.5 7.5 25 P1-25/... EA/SVB/N/HI11048367

– V/SVB/N/HI11053113

EA/SVB-SW/N/HI11050740

– V/SVB-SW/N/HI11055486

7.5 13 15 32 P1-32/... EA/SVB/N/HI11057859

– V/SVB/N/HI11062605

EA/SVB-SW/N/HI11060232

– V/SVB-SW/N/HI11064978

15 30 30 63 P3-63/... EA/SVB/N/HI11067351

I4/SVB/N/HI11207350

V/SVB/N/HI11072097

EA/SVB-SW/N/HI11069724

I4/SVB-SW/N/HI11207347

V/SVB-SW/N/HI11074470

22 37 37 100 P3-100/... EA/SVB/N/HI11076843

I5/SVB/N/HI11207380

V/SVB/N/HI11081589

EA/SVB-SW/N/HI11079216

I5/SVB-SW/N/HI11207377

V/SVB-SW/N/HI11083962

3+N 1 1 3 4 4 20 T0-3-15681/... EA/SVB086335

I1/SVB207155

V/SVB091081

EA/SVB-SW088708

I1/SVB-SW207156

V/SVB-SW093454

6.5 12 15 32 T3-3-15681/... EA/SVB026240

I2/SVB207204

V/SVB030986

EA/SVB-SW028613

I2/SVB-SW207205

V/SVB-SW033359

15 22 22 63 T5B-3-8901/... EA/SVB207420

I4/SVB207244

V/SVB207422

EA/SVB-SW207421

I4/SVB-SW207245

V/SVB-SW207423

18.5 30 30 100 T5-3-8901/... EA/SVB207408

I5/SVB207277

V/SVB207410

EA/SVB-SW207409

I5/SVB-SW207278

V/SVB-SW207411

6 1 1 3 4 4 20 T0-4-15682/... EA/SVB019892

I1/SVB207161

V/SVB024638

EA/SVB-SW022265

I1/SVB-SW207162

V/SVB-SW027011

6.5 12 15 32 T3-4-15682/... EA/SVB054716

I2/SVB207210

V/SVB059462

EA/SVB-SW057089

I2/SVB-SW207211

V/SVB-SW061835

15 22 22 63 T5B-4-15682/... EA/SVB207425

I4/SVB207246

V/SVB207427

EA/SVB-SW207426

I4/SVB-SW207247

V/SVB-SW207428

18.5 30 30 100 T5-4-15682/... EA/SVB207413

I5/SVB207281

V/SVB207415

EA/SVB-SW207414

I5/SVB-SW207282

V/SVB-SW207416

6 1 1 22 42 22 160 T6-160-6/... – I45/SVB/HI115)

201448V/SVB/HI11200619

– I45/SVB-SW/HI115)

201447V/SVB-SW/HI11200127

37 55 37 3153) T8-3-8342/... – I48/SVB/HI116)

201450V/SVB/HI11200620

– I48/SVB-SW/HI116)

201449V/SVB-SW/HI11200128

Standard pack: 1 off Standard pack: 1 off

Notes 1) To IEC/EN 60 204-1; with red rotary handle and yellow locking collar, lockable in 0 (Off) position2) With black rotary handle and locking collar, lockable in 0 (Off) position3) Enclosed version, up to 275 A4) Enclosure designed for metric cable glands to EN 50 262, cable glands

a Page 07/0705) Enclosures without flanges, with K95/1N/BR

6) With KS4-CI and K150/1/BR

FS 908

ON

OFF

2

1 3

4

5

6

7

8

2

1 3

4

5

6

13

14 22

21

L2 L3L1

2

1 3

4

5

6

7

8

9

10 12

11

L2 L3 NL1

2

1 3

4

5

6

7

8

9

10 12

11

N

2

1 3

4

5

6

13 21

14 22

L2 L3

N

L1

L2 L3 NL1

2

1 3

4

5

6

7

8

9

10 12

11

2

1 3

4

5

6

7

8

9

10 12

11 13

14 16

15

2

1 3

4

5

6

7

8

9

10 12

11 13

14 22

21

07/014 07/015

Page 15: 07/000 T Rotary Switches, P Switch-Disconnectors · Moeller HPL0211-2001/2002 T Rotary Switches, P Switch-Disconnectors Overview of Functions Rotary Switches Switch-Disconnectors

Moeller HPL0211-2001/2002

T Rotary Switches, P Switch-DisconnectorsMain Switches, Maintenance Switches in Sheet Steel Enclosures

Rota

ry S

witc

hes

Swit

ch-D

isco

nnec

tors

Rota

ry S

wit

ches

Swit

ch-D

isco

nnec

tors

Moeller HPL0211-2001/2002

T Rotary Switches, P Switch-DisconnectorsMain Switches, Maintenance Switches in Sheet Steel Enclosures

For use as Emergency-Stop device1)

Without Emergency-Stop function2)

Circuit diagram Front plate no.

Main contacts

Auxiliary contacts

Max. three-phasemotor rating (per set of 3 contacts)50–60 Hz

Rated uninter-rupted current

Surface mountingIP65

Surface mountingIP65

No. of poles AC-3

220 V230 V240 V

380 V400 V440 V

660 V690 V

Iu

Basic typeFor ... insert mounting form

Mounting formArticle no.

PriceSee Price List

Mounting formArticle no.

PriceSee Price ListM M B kW kW kW A

Main switches in sheet steel enclosures3 0 0 3 4 4 20 T0-2-1/... ST/SVB

025528ST/SVB-SW201713

5.5 7.5 7.5 25 P1-25/... ST/SVB025523

ST/SVB-SW201714

7.5 13 15 32 P1-32/... ST/SVB025522

ST/SVB-SW201715

15 30 30 63 P3-63/... ST/SVB025521

ST/SVB-SW201716

22 37 37 100 P3-100/... ST/SVB025520

ST/SVB-SW201717

Main switches with auxiliary contacts6 1 1 3 4 4 20 T0-4-15682/... ST/SVB

025527ST/SVB-SW201718

6.5 12 15 32 T3-4-15682/... ST/SVB025526

ST/SVB-SW201719

15 22 22 63 T5B-4-15682/... ST/SVB215328

ST/SVB-SW215329

18.5 30 30 100 T5-4-15682/... ST/SVB215330

ST/SVB-SW215331

Standard pack: 1 off Standard pack: 1 off

Notes 1) To IEC/EN 60 204-1; with red rotary handle and yellow locking collar, lockable in 0 (Off) position2) With black rotary handle and locking collar, lockable in 0 (Off) position

FS 908

ON

OFF

1 3 5

2 4 6

2

1 3

4

5

6

7

8

9

10 12

11 13

14 16

15

07/016 07/017

Page 16: 07/000 T Rotary Switches, P Switch-Disconnectors · Moeller HPL0211-2001/2002 T Rotary Switches, P Switch-Disconnectors Overview of Functions Rotary Switches Switch-Disconnectors

Moeller HPL0211-2001/2002

T Rotary Switches, P Switch-DisconnectorsOn-Off Switches

Rota

ry S

witc

hes

Swit

ch-D

isco

nnec

tors

Rota

ry S

wit

ches

Swit

ch-D

isco

nnec

tors

Moeller HPL0211-2001/2002

T Rotary Switches, P Switch-DisconnectorsOn-Off Switches

Circuit diagram Front plate no.

Main contacts

Auxiliary contacts

Max. three-phasemotor rating (per set of 3 contacts)50–60 Hz

Rated uninter-rupted current

Flush mountingFront IP65

Centre mountingFront IP65

Surface mounting 2) IP65

Service distribution board mountingFront IP30

Rear mountingFront IP65

No. of poles AC-3

220 V230 V240 V

380 V400 V440 V

660 V690 V

Iu

Basic typeFor ... insert mounting form

Mounting formArticle no.

PriceSee Price List

Mounting formArticle no.

PriceSee Price List

Mounting formArticle no.

PriceSee Price List

Mounting formArticle no.

PriceSee Price List

Mounting formArticle no.

PriceSee Price List

M M B kW kW kW A

On-Off switches1)

1 0 0 1 1.3 – 20 T0-1-8200/... E067352

EZ069725

I1207074

IVS074471

Z076844

1.8 3.6 – 32 T3-1-8200/... E064208

EZ066581

I2207167

– Z071327

5 7.3 – 63 T5B-1-8200/... E094281

– I4207218

– Z094270

7.3 12.3 – 100 T5-1-8200/... E097226

– I5207264

– Z097219

2 0 0 2.2 2.2 – 20 T0-1-102/... E088709

EZ091082

I1207061

IVS015147

Z095828

3 5.5 – 32 T3-1-102/... E076073

EZ078446

I2207165

– Z083192

7.5 11 – 63 T5B-1-102/... E094471

– I4207215

– Z094460

11 18.5 – 100 T5-1-102/... E098810

– I5207262

– Z098803

3 0 0 3 4 4 20 T0-2-1/... E024639

EZ027012

I1207081

IVS031758

Z036504

5.5 7.5 7.5 25 P1-25/... E038724

EZ041250

I2207299

IVS052962

Z057708

7.5 13 15 32 P1-32/... E079065

EZ048369

I2207320

IVS093303

Z098049

15 30 30 63 P3-63/... E026861

– I4207356

IVS041099

Z050591

22 37 37 100 P3-100/... E067201

– I5207381

IVS081439

Z090931

22 37 22 125 T6-2/... E098106

– – – –

3+N 0 0 3 4 4 20 T0-2-8900/... E207398

EZ207402

I1207109

IVS207403

Z207407

5.5 7.5 7.5 25 P1-25/... E/N076845

EZ/N079218

I2/N207303

IVS/N083964

Z/N088710

7.5 13 15 32 P1-32/... E/N093456

EZ/N095829

I2/N207324

IVS/N010402

Z/N015148

15 30 30 63 P3-63/... E/N019894

– I4/N207360

IVS/N022267

Z/N027013

22 37 37 100 P3-100/... E/N031759

– I5/N207385

IVS/N034132

Z/N038878

6 0 0 3 4 4 20 T0-3-8342/... E043624

EZ045997

I1207131

IVS050743

Z055489

6.5 12 15 32 T3-3-8342/... E045225

EZ047598

I2207187

– Z052344

15 22 22 63 T5B-3-8342/... E092310

– I4207226

– Z092297

18.5 30 30 100 T5-3-8342/... E096385

– I5207267

– Z096378

8 0 0 3 4 4 20 T0-4-8344/... E014000

EZ014002

I1207139

IVS014006

Z014009

6.5 12 – 32 T3-4-8344/... E020593

EZ020595

I2207194

– Z020600

15 22 22 63 T5B-4-8344/... E092064

– I4207233

– Z092053

22 30 30 1003) T5-4-8344/... E095963

– I5207272

– Z095956

Standard pack: 1 off Standard pack: 1 off

Notes 1) With black thumb-grip and grey front plate2) Enclosure designed for metric cable glands to EN 50 262, cable glands

a Page 07/0703) T5-4-8344/I5 up to 95 A

FS 908

ON

OFF

1

2

1

2

3

4

1 3 5

2 4 6

2

1 3

4

5

6

7

8

2

1 3

4

5

6

N

N2

1 3

4

5

6

N

N

2

1 3

4

5

6

7

8

9

10 12

11

2

1 3

4

5

6

7

8

9

10 12

11 13

14 16

15

07/018 07/019

Page 17: 07/000 T Rotary Switches, P Switch-Disconnectors · Moeller HPL0211-2001/2002 T Rotary Switches, P Switch-Disconnectors Overview of Functions Rotary Switches Switch-Disconnectors

Moeller HPL0211-2001/2002

T Rotary Switches, P Switch-DisconnectorsOn-Off Switches with Auxiliary Contacts

Rota

ry S

witc

hes

Swit

ch-D

isco

nnec

tors

Rota

ry S

wit

ches

Swit

ch-D

isco

nnec

tors

Moeller HPL0211-2001/2002

T Rotary Switches, P Switch-DisconnectorsOn-Off Switches with Auxiliary Contacts

Circuit diagram Front plate no.

Main contacts

Auxiliary contacts

Max. three-phasemotor rating (per set of 3 contacts)50–60 Hz

Rated uninter-rupted current

Flush mountingFront IP65

Centre mountingFront IP65

Surface mounting 2) IP65

Service distribution board mountingFront IP30

Rear mountingFront IP65

No. of poles AC-3

220 V230 V240 V

380 V400 V440 V

660 V690 V

Iu

Basic typeFor ... insert mounting form

Mounting formArticle no.

PriceSee Price List

Mounting formArticle no.

PriceSee Price List

Mounting formArticle no.

PriceSee Price List

Mounting formArticle no.

PriceSee Price List

Mounting formArticle no.

PriceSee Price List

M M B kW kW kW A

On-Off switches with auxiliary contacts1)

3 1 0 3 4 4 20 T0-2-15679/... E029387

EZ031760

I1207094

IVS036506

Z041252

3 1 1 5.5 7.5 7.5 25 P1-25/... E/HI11045998

EZ/HI11048371

I2/HI11207302

IVS/HI11053117

Z/HI11057863

7.5 13 15 32 P1-32/... E/HI11062609

EZ/HI11064982

I2/HI11207323

IVS/HI11069728

Z/HI11074474

15 30 30 63 P3-63/... E/HI11079220

– I4/HI11207359

IVS/HI11081593

Z/HI11086339

22 37 37 100 P3-100/... E/HI11069574

– I5/HI11207384

IVS/HI11091085

Z/HI11093304

3 2 1 3 4 4 20 T0-3-15683/... E016619

EZ016658

I1207118

IVS016722

Z016843

6.5 12 15 32 T3-3-15683/... E014377

EZ040480

I2207182

– Z019123

6 1 1 3 4 4 20 T0-4-15682/... E010405

EZ012778

I1207135

IVS017524

Z022270

6.5 12 15 32 T3-4-15682/... E023869

EZ026242

I2207190

– Z030988

15 22 22 63 T5B-4-15682/... E207424

– I4207229

– Z207429

18.5 30 30 100 T5-4-15682/... E207412

– I5207269

– Z207417

Standard pack: 1 off Standard pack: 1 off

Notes 1) With black thumb-grip and grey front plate2) Enclosure designed for metric cable glands to EN 50 262, cable glands

a Page 07/070

FS 908

ON

OFF

2

1 3

4

5

6

7

8

2

1 3

4

5

6

13

14 22

21

L2 L3L1

2

1 3

4

5

6

7

8

9

10 12

11

2

1 3

4

5

6

7

8

9

10 12

11 13

14 16

15

07/020 07/021

Page 18: 07/000 T Rotary Switches, P Switch-Disconnectors · Moeller HPL0211-2001/2002 T Rotary Switches, P Switch-Disconnectors Overview of Functions Rotary Switches Switch-Disconnectors

Moeller HPL0211-2001/2002

T Rotary Switches, P Switch-DisconnectorsOn-Off Switches

Rota

ry S

witc

hes

Swit

ch-D

isco

nnec

tors

Rota

ry S

wit

ches

Swit

ch-D

isco

nnec

tors

Moeller HPL0211-2001/2002

T Rotary Switches, P Switch-DisconnectorsOn-Off Switches

Circuit diagram Front plate no.

Main contacts

Auxiliary contacts

Max. three-phasemotor rating (per set of 3 contacts)50–60 Hz

Rated uninter-rupted current

Flush mountingFront IP65

Surface mounting 2) IP65

Service distribution board mountingFront IP30

No. of poles AC-3

220 V230 V240 V

380 V400 V440 V

660 V690 V

Iu

Basic typeFor ... insert mounting form

Mounting formArticle no.

PriceSee Price List

Mounting formArticle no.

PriceSee Price List

Mounting formArticle no.

PriceSee Price List

M M B kW kW kW A

On-Off switches for use as Emergency-Stop devices1)

1 0 0 1 1.3 – 20 T0-1-8200/... E-RT009474

I1-RT207075

IVS-RT081956

1.8 3.6 – 32 T3-1-8200/... E-RT017025

I2-RT207168

5 7.3 – 63 T5B-1-8200/... E-RT094280

I4-RT207219

7.3 12.3 – 100 T5-1-8200/... E-RT097225

I5-RT207265

2 0 0 2.2 2.2 – 20 T0-1-102/... E-RT009046

I1-RT207062

IVS-RT079583

3 5.5 – 32 T3-1-102/... E-RT016318

I2-RT207166

7.5 11 – 63 T5B-1-102/... E-RT094470

I4-RT207216

11 18.5 – 100 T5-1-102/... E-RT098809

I5-RT207263

3 0 0 3 4 4 20 T0-2-1/... E-RT011082

I1-RT207082

IVS-RT084329

5.5 7.5 7.5 25 P1-25/... E-RT002388

I2-RT207300

IVS-RT013140

7.5 13 15 32 P1-32/... E-RT003197

I2-RT207321

IVS-RT022632

15 30 30 63 P3-63/... E-RT005743

I4-RT207357

IVS-RT045845

22 37 37 100 P3-100/... E-RT007189

I5-RT207382

IVS-RT086185

3+N 0 0 3 4 4 20 T0-2-8900/... E-RT207399

I1-RT207110

IVS-RT207404

5.5 7.5 7.5 25 P1-25/... E-RT/N002425

I2-RT/N207301

IVS-RT/N017886

7.5 13 15 32 P1-32/... E-RT/N004555

I2-RT/N207322

IVS-RT/N027378

15 30 30 63 P3-63/... E-RT/N007136

I4-RT/N207358

IVS-RT/N041616

22 37 37 100 P3-100/... E-RT/N007280

I5-RT/N207383

IVS-RT/N034497

Standard pack: 1 off Standard pack: 1 off

Notes 1) To IEC/EN 60 204-1; with red thumb-grip and yellow front plate2) Enclosure designed for metric cable glands to EN 50 262, cable glands

a Page 07/070

FS 908 GE

1

0

1

2

1

2

3

4

1 3 5

2 4 6

2

1 3

4

5

6

7

8

2

1 3

4

5

6

N

N

07/022 07/023

Page 19: 07/000 T Rotary Switches, P Switch-Disconnectors · Moeller HPL0211-2001/2002 T Rotary Switches, P Switch-Disconnectors Overview of Functions Rotary Switches Switch-Disconnectors

Moeller HPL0211-2001/2002

T Rotary Switches, P Switch-DisconnectorsSafety Switches

Rota

ry S

witc

hes

Swit

ch-D

isco

nnec

tors

Rota

ry S

wit

ches

Swit

ch-D

isco

nnec

tors

Moeller HPL0211-2001/2002

T Rotary Switches, P Switch-DisconnectorsSafety Switches

For use as Emergency-Stop device1)

Without Emergency-Stop function2)

Circuit diagram Front plate no.

Main contacts

Auxiliary contacts

Max. three-phasemotor rating (per set of 3 contacts)50–60 Hz

Rated uninter-rupted current

Surface mountingIP65

Surface mounting 3) IP65

Notes

No. of poles AC-3

220 V230 V240 V

380 V400 V440 V

660 V690 V

Iu

TypeArticle no.

PriceSee Price List

TypeArticle no.

PriceSee Price ListM M B kW kW kW A

Safety switches3 0 0 5.5 7.5 7.5 25 P1-25/I2-SI

207308P1-25/I2-SI-SW207309

Padlocking feature with captive cover fixing

With “Safety Switch” warning plate(other languages on request)Neutral conductor or HI11 auxiliary contact can also be retrofitted to P1 and P3 safety switches

a Page 07/065

For general information onSafety Switches

a Page 07/109For switches in accordance with the Swiss Accident Insurance Institute Directive, please contact Moeller Switzerland

7.5 13 15 32 P1-32/I2-SI207329

P1-32/I2-SI-SW207330

3+N 0 0 5.5 7.5 7.5 25 P1-25/I2-SI/N207312

P1-25/I2-SI/N-SW207313

7.5 13 15 32 P1-32/I2-SI/N207333

P1-32/I2-SI/N-SW207334

With auxiliary contacts 3 1 1 5.5 7.5 7.5 25 P1-25/I2-SI/HI11207310

P1-25/I2-SI/HI11-SW207311

7.5 13 15 32 P1-32/I2-SI/HI11207331

P1-32/I2-SI/HI11-SW207332

3 0 0 15 30 30 63 P3-63/I4-SI207361

P3-63/I4-SI-SW207362

22 37 37 100 P3-100/I5-SI207386

P3-100/I5-SI-SW207387

3+N 0 0 15 30 30 63 P3-63/I4-SI/N207365

P3-63/I4-SI/N-SW207366

22 37 37 100 P3-100/I5-SI/N207390

P3-100/I5-SI/N-SW207391

With auxiliary contacts 3 1 1 15 30 30 63 P3-63/I4-SI/HI11207363

P3-63/I4-SI/HI11-SW207364

22 37 37 100 P3-100/I5-SI/HI11207388

P3-100/I5-SI/HI11-SW207389

6 0 0 15 22 22 63 T5B-3-8342/I4-SI207250

T5B-3-8342/I4-SI-SW207251

No contacts can be retrofitted to T... rotary switches.

18.5 30 30 100 T5-3-8342/I5-SI207447

T5-3-8342/I5-SI-SW207448

With auxiliary contacts 6 1 1 15 22 22 63 T5B-4-15682/I4-SI207254

T5B-4-15682/I4-SI-SW207255

18.5 30 30 100 T5-4-15682/I5-SI207285

T5-4-15682/I5-SI-SW207286

With auxiliary contacts 6 2 0 15 22 22 63 T5B-4-8903/I4-SI207258

T5B-4-8903/I4-SI-SW207259

18.5 30 30 100 T5-4-8903/I5-SI207289

T5-4-8903/I5-SI-SW207290

Standard pack: 1 off Standard pack: 1 off

Notes 1) To IEC/EN 60 204 Part 1; with red rotary handle and yellow locking collar, lockable in 0 (Off) positionwith cover interlock

2) With black rotary handle and locking collar, lockable in 0 (Off) position with cover interlock3) Enclosure designed for metric cable glands to EN 50 262, cable glands

a Page 07/070

FS 908

ON

OFF

1 3 5

2 4 6

2

1 3

4

5

6

N

N

2

1 3

4

5

6

13

14 22

21

1 3 5

2 4 6

2

1 3

4

5

6

N

N

2

1 3

4

5

6

13

14 22

21

2

1 3

4

5

6

7

8

9

10 12

11

2

1 3

4

5

6

7

8

9

10 12

11 13

14 22

21

2

1 3

4

5

6

7

8

9

10 12

11 13

14 16

15

07/024 07/025

Page 20: 07/000 T Rotary Switches, P Switch-Disconnectors · Moeller HPL0211-2001/2002 T Rotary Switches, P Switch-Disconnectors Overview of Functions Rotary Switches Switch-Disconnectors

Moeller HPL0211-2001/2002

T Rotary SwitchesControl Switches: Changeover Switches

Rota

ry S

witc

hes

Swit

ch-D

isco

nnec

tors

Rota

ry S

wit

ches

Swit

ch-D

isco

nnec

tors

Moeller HPL0211-2001/2002

T Rotary SwitchesControl Switches: Changeover Switches

Circuit diagram Front plate no.

Max. three-phasemotor rating (per set of 3 contacts)50 – 60 Hz

Rated unin-terrupted current

Iu

Flush mountingFront IP65

Centre mountingFront IP65

Surface mounting 2) IP65

Service distribution board mountingFront IP30

Rear mountingFront IP65

No. of poles AC-3

220 V230 V240 V

380 V400 V440 V

660 V690 V

Basic typeFor ... insert mounting form

Mounting formArticle no.

PriceSee Price List

Mounting formArticle no.

PriceSee Price List

Mounting formArticle no.

PriceSee Price List

Mounting formArticle no.

PriceSee Price List

Mounting formArticle no.

PriceSee Price List

M kW kW kW A

Changeover switches with 0 (Off) position 1)

Group switches, mains transfer switches1 1 1.3 – 20 T0-1-8210/... E

012742EZ048337

I1207076

IVS074440

Z019862

1.8 3.6 – 32 T3-1-8210/... E054718

EZ003072

I2207169

– Z057091

5 7.3 – 63 T5B-1-8210/... E094261

– I4207432

– Z094258

2 2.2 2.2 – 20 T0-2-8211/... E022234

EZ053083

I1207102

IVS076813

Z029354

3 5.5 – 32 T3-2-8211/... E061837

EZ003075

I2207178

– Z064210

7.5 11 – 63 T5B-2-8211/... E093094

– I4207220

– Z093082

3 3 4 4 20 T0-3-8212/... E029353

EZ057829

I1207123

IVS079186

Z036473

6.5 12 15 32 T3-3-8212/... E068956

EZ003080

I2207183

– Z071329

15 22 22 63 T5B-3-8212/... E092386

– I4207223

– Z092383

18.5 30 30 100 T5-3-8212/... E096466

– I5207266

– Z096464

3 22 37 22 125 T6-3-8212/... E/HI12214781

– – – –

37 55 37 315 T8-3-8212/... E/HI12214782

– – – –

4 3 4 4 20 T0-4-8213/... E031726

EZ062575

I1207136

IVS081559

Z043592

6.5 12 15 32 T3-4-8213/... E076075

EZ003079

I2207191

– Z078448

15 22 22 63 T5B-4-8213/... E092112

– I4207230

– Z092109

18.5 30 30 100 T5-4-8213/... E096014

– I5207270

– Z096012

4 3 4 4 20 T0-4-8294/... E010371

EZ072069

I1207138

IVS043594

Z048347

6.5 12 15 32 T3-4-8294/... E002513

EZ001014

I2207193

– Z004886

15 22 22 63 T5B-4-8294/... E092084

– I4207232

– Z092081

18.5 30 22 100 T5-4-8294/... E095986

– I5207433

– Z095984

4 6.5 12 15 32 T3-4-8902/... E215222

EZ215223

I2215224

– Z215225

15 22 22 63 T5B-4-8902/... E207430

– I4207237

– Z207431

18.5 30 22 100 T5-4-8902/... E207418

– I5207214

– Z207419

Standard pack: 1 off Standard pack: 1 off

Notes 1) With black thumb-grip and grey front plate2) Enclosure designed for metric cable glands to EN 50 262, cable glands

a Page 07/070

201

2

1 3

4

FS 684

01 2

201

2

1 3

4

5

6

7

8

FS 684

01 2

201

2

1 3

4

5

6

7

8

9

10

11

12

FS 684

01 2

2

1 3

4

5

6

7

8

9

10

11

12

11

12

101

102

103

104

105

106

201

FS 684

01 2

201

2

1 3

4

5

6

7

8

9

10

11

12

13 15

1614

FS 684

01 2

201

2

1 3

4

5

6

7

8

9

10

11

12

13 15

1614

FS 953

0

1 2

2

1 3

4

5

6

7

8

9

10

11

12

13 15

1614

Emergencysupply

0Mains

0

FS 161629

NETZNOT-

STROM

07/026 07/027

Page 21: 07/000 T Rotary Switches, P Switch-Disconnectors · Moeller HPL0211-2001/2002 T Rotary Switches, P Switch-Disconnectors Overview of Functions Rotary Switches Switch-Disconnectors

Moeller HPL0211-2001/2002

T Rotary SwitchesControl Switches: Changeover Switches

Rota

ry S

witc

hes

Swit

ch-D

isco

nnec

tors

Rota

ry S

wit

ches

Swit

ch-D

isco

nnec

tors

Moeller HPL0211-2001/2002

T Rotary SwitchesControl Switches: Changeover Switches

Circuit diagram Front plate no.

Max. three-phasemotor rating (per set of 3 contacts)50–60 Hz

Rated uninter-rupted current

Iu

Flush mountingFront IP65

Centre mountingFront IP65

Surface mounting 2) IP65

Service distribution board mountingFront IP30

Rear mountingFront IP65

No. of poles AC-3

220 V230 V240 V

380 V400 V440 V

660 V690 V

Basic typeFor ... insert mounting form

Mounting formArticle no.

PriceSee Price List

Mounting formArticle no.

PriceSee Price List

Mounting formArticle no.

PriceSee Price List

Mounting formArticle no.

PriceSee Price List

Mounting formArticle no.

PriceSee Price List

M kW kW kW A

Changeover switches with 0 (Off) position1)

With spring-return from both directions to 01 1 1.3 – 20 T0-1-8214/... E

019863EZ076815

I1207077

IVS045967

Z050720

1.8 3.6 – 32 T3-1-8214/... E009632

EZ001073

I2207170

– Z012005

2 2.2 2.2 – 20 T0-2-8215/... E022236

EZ081561

I1207103

IVS048340

Z053093

3 5.5 – 32 T3-2-8215/... E016751

EZ001074

I2207179

– Z019124

3 3 4 4 20 T0-3-8216/... E024609

EZ086307

I1207434

IVS050713

Z055466

6.5 12 15 32 T3-3-8216/... E023870

EZ001077

I2207184

– Z026243

Standard pack: 1 off Standard pack: 1 off

Notes 1) With black thumb-grip and grey front plate2) Enclosure designed for metric cable glands to EN 50 262, cable glands

a Page 07/070

FS 4011

01 2

2

10

2

1 3

4

102

2

1 3

4

5

6

7

8

102

2

1 3

4

5

6

7

8

9

10

11

12

07/028 07/029

Page 22: 07/000 T Rotary Switches, P Switch-Disconnectors · Moeller HPL0211-2001/2002 T Rotary Switches, P Switch-Disconnectors Overview of Functions Rotary Switches Switch-Disconnectors

Moeller HPL0211-2001/2002

T Rotary SwitchesControl Switches: Changeover Switches

Rota

ry S

witc

hes

Swit

ch-D

isco

nnec

tors

Rota

ry S

wit

ches

Swit

ch-D

isco

nnec

tors

Moeller HPL0211-2001/2002

T Rotary SwitchesControl Switches: Changeover Switches

Circuit diagram Front plate no.

Max. three-phasemotor rating (per set of 3 contacts)50–60 Hz

Rated uninter-rupted current

Iu

Flush mountingFront IP65

Centre mountingFront IP65

Surface mounting 2) IP65

Service distribution board mountingFront IP30

Rear mountingFront IP65

No. of poles AC-3

220 V230 V240 V

380 V400 V440 V

660 V690 V

Basic typeFor ... insert mounting form

Mounting formArticle no.

PriceSee Price List

Mounting formArticle no.

PriceSee Price List

Mounting formArticle no.

PriceSee Price List

Mounting formArticle no.

PriceSee Price List

Mounting formArticle no.

PriceSee Price List

M kW kW kW A

Changeover switches without 0 (Off) position1)

Changeover switches1 1.1 1.3 – 20 T0-1-8220/... E

031728EZ095799

I1207078

IVS055459

Z086312

1.8 3.6 – 32 T3-1-8220/... E038108

EZ001018

I2207171

– Z040481

2 2.2 2.2 – 20 T0-2-8221/... E038847

EZ010372

I1207104

IVS057832

Z074450

3 5.5 – 32 T3-2-8221/... E045227

EZ001025

I2207180

– Z047600

7.5 11 – 63 T5B-2-8221/... E093047

– I4207221

– Z093044

3 3 4 4 20 T0-3-8222/... E048339

EZ015118

I1207124

IVS060205

Z088686

6.5 12 15 32 T3-3-8222/... E052346

EZ001069

I2207185

– Z057092

15 22 22 63 T5B-3-8222/... E092378

– I4207224

– Z092375

4 3 4 4 20 T0-4-8223/... E050712

EZ019864

I1207137

IVS062578

Z086315

6.5 12 15 32 T3-4-8223/... E059465

EZ001070

I2207192

– Z061838

15 22 22 63 T5B-4-8223/... E092108

– I4207231

– Z092105

18.5 30 30 100 T5-4-8223/... E096010

– I5207271

– Z096008

5 3 4 4 20 T0-5-8369/... E060204

EZ024610

– IVS064951

Z098180

6.5 12 15 32 T3-5-8369/... E066584

EZ004503

I2207536

– Z068957

6 3 4 4 20 T0-6-8370/... E062577

EZ029356

– IVS067324

Z010380

6.5 12 15 32 T3-6-8370/... E073703

EZ004506

– – Z078449

8 3 4 4 20 T0-8-8372/... E064950

EZ034102

– IVS069697

Z012753

6.5 12 15 32 T3-8-8372/... E080822

EZ004508

– Z083195

Standard pack: 1 off Standard pack: 1 off

Notes 1) With black thumb-grip and grey front plate2) Enclosure designed for metric cable glands to EN 50 262, cable glands

a Page 07/070

1 2

FS 943

12

2

1 3

4

12

2

1 3

4

5

6

7

8

12

2

1 3

4

5

6

7

8

9

10

11

12

12

2

1 3

4

5

6

7

8

9

10

11

12

13 15

1614

12

2

1 3

4

5

6

7

8

9

10

11

12

13 15

1614

17 19

2018

12

2

1 3

4

5

6

7

8

9

10

11

12

13 15

1614

17 19

2018

21

22 24

23

12

2

1 3

4

5

6

7

8

9

10

11

12

13 15

1614

17 19

2018

21

22 24

23 25 27 29 31

26 28 30 32

07/030 07/031

Page 23: 07/000 T Rotary Switches, P Switch-Disconnectors · Moeller HPL0211-2001/2002 T Rotary Switches, P Switch-Disconnectors Overview of Functions Rotary Switches Switch-Disconnectors

Moeller HPL0211-2001/2002

T Rotary SwitchesControl Switches: Reversing Switches, Star-Delta Switches

Rota

ry S

witc

hes

Swit

ch-D

isco

nnec

tors

Rota

ry S

wit

ches

Swit

ch-D

isco

nnec

tors

Moeller HPL0211-2001/2002

T Rotary SwitchesControl Switches: Reversing Switches, Star-Delta Switches

Circuit diagram Front plate no.

Max. three-phasemotor rating (per set of 3 contacts)50–60 Hz

Rated unin-terrupted current

Iu

Flush mountingFront IP65

Centre mountingFront IP65

Surface mounting 2) IP65

Service distribution board mountingFront IP30

Rear mountingFront IP65

No. of poles AC-3

220 V230 V240 V

380 V400 V440 V

660 V690 V

Basic typeFor ... insert mounting form

Mounting formArticle no.

PriceSee Price List

Mounting formArticle no.

PriceSee Price List

Mounting formArticle no.

PriceSee Price List

Mounting formArticle no.

PriceSee Price List

Mounting formArticle no.

PriceSee Price List

M kW kW kW A

Reversing switches with 0 (Off) position1)

2 2.2 2.2 – 20 T0-2-8400/... E053079

EZ055452

I1207111

IVS060198

Z062571

3 5.5 – 32 T3-2-8400/... E073695

EZ000687

I2207181

– Z095060

7.5 11 – 63 T5B-2-8400/... E092918

– I4207222

– Z092915

3 3 4 4 20 T0-3-8401/... E091047

EZ093420

I1207132

IVS098166

Z010366

6.5 12 15 32 T3-3-8401/... E030992

EZ000694

I2207188

– Z035739

15 22 22 63 T5B-3-8401/... E092296

– I4207227

– Z092293

18.5 30 30 100 T5-3-8401/... E096376

– I5207268

– Z096374

With spring-return from both directions to 03 3 4 4 20 T0-3-8228/... E

015112EZ048334

I1207125

IVS062572

Z074437

6.5 12 15 32 T3-3-8228/... E002538

EZ000695

I2207186

– Z004911

15 22 22 63 T5B-3-8228/... E092374

– I4207225

– Z092371

Star-delta switches1)

3 4 5.5 5.5 20 T0-4-8410/... E024604

EZ053080

I1207140

IVS064945

Z083929

7.5 18.5 22 32 T3-4-8410/... E009657

EZ000721

I2207195

– Z012030

22 37 37 63 T5B-4-8410-/... E092052

– I4207234

– Z092049

Reversing Star-delta switches1)

Two-way switches3 4 5.5 5.5 20 T0-5-15876/... E

000893EZ000900

– IVS000902

Z000942

7.5 18.5 22 32 T3-5-15876/... E016776

EZ000797

I2207537

– Z019149

3 22 30 37 63 T5B-5-15876/... E214785

– – – Z214786

Standard pack: 1 off Standard pack: 1 off

Notes 1) With black thumb-grip and grey front plate2) Enclosure designed for metric cable glands to EN 50 262, cable glands

a Page 07/070

201

2

1 3

4

5

6

7

8

FS 684

01 2

201

1 3 5

2 4 6

7

8

9

10

FS 684

01 2

102

1 3 5

2 4 6

7

8

9

10

FS 4011

01 2

Y0

2

1 3

4

5

6

7

8

9

10

11 13 15

12 14 16

FS 635

Y0

Y

Y0

2

1 3

4

5

6

7

8

9 11 13 15 17 19

10 12 14 16 18 20

FS 638

Y0

Y

Y

Y0

2

1 3

4

5

6

7

8

9 11 13 15 17 19

10 12 14 16 18 20

FS 4017

Y0

Y

07/032 07/033

Page 24: 07/000 T Rotary Switches, P Switch-Disconnectors · Moeller HPL0211-2001/2002 T Rotary Switches, P Switch-Disconnectors Overview of Functions Rotary Switches Switch-Disconnectors

Moeller HPL0211-2001/2002

T Rotary SwitchesControl Switches: Multi-Speed Switches, Reversing Multi-Speed Switches

Rota

ry S

witc

hes

Swit

ch-D

isco

nnec

tors

Rota

ry S

wit

ches

Swit

ch-D

isco

nnec

tors

Moeller HPL0211-2001/2002

T Rotary SwitchesControl Switches: Multi-Speed Switches, Reversing Multi-Speed Switches

Circuit diagram

Front plateno.

Max. three-phasemotor rating (per set of 3 contacts)50–60 Hz

Rated unin-terrupted current

Iu

Flush mountingFront IP65

Centre mountingFront IP65

Surface mounting 2)

IP65

Service distribution board mountingFront IP30

Rear mountingFront IP65

No. of poles

AC-3220 V230 V240 V

380 V400 V440 V

660 V690 V

Basic typeFor ... insert mounting form

Mounting formArticle no.

PriceSee Price List

Mounting formArticle no.

PriceSee Price List

Mounting formArticle no.

PriceSee Price List

Mounting formArticle no.

PriceSee Price List

Mounting formArticle no.

PriceSee Price List

M kW kW kW A

Multi-speed switches1)

Two-speed, non reversingFor 2 separate windings

3 3 4 4 20 T0-3-8451/... E038849

EZ083936

I1207133

IVS026985

Z043596

6.5 12 15 32 T3-3-8451/... E028641

EZ000956

I2207189

– Z031014

15 22 22 63 T5B-3-8451/... E092288

– I4207228

– Z092285

For one tapped winding3 3 4 4 20 T0-4-8440/... E

041222EZ088682

I1207141

IVS029358

Z048342

6.5 12 15 32 T3-4-8440/... E035760

EZ000959

I2207196

– Z038133

15 22 22 63 T5B-4-8440/... E092032

– I4207235

– Z092029

3 3 4 4 20 T0-4-8441/... E043595

EZ093428

I1207142

IVS031731

Z053088

6.5 12 15 32 T3-4-8441/... E042879

EZ000960

I2207197

– Z045252

15 22 22 63 T5B-4-8441/... E092028

– I4207236

– Z092025

Reversing multi-speed switches1)

Two-speed, two directionsFor one tapped winding

3 3 4 4 20 T0-6-15866/... E055460

EZ012747

– IVS036477

Z067326

6.5 12 15 32 T3-6-15866/... E054744

EZ000964

– – Z057117

3 15 22 22 63 T5B-7-15866/... E214788

– – – Z214789

Standard pack: 1 off Standard pack: 1 off

Notes 1) With black thumb-grip and grey front plate2) Enclosure designed for metric cable glands to EN 50 262, cable glands

a Page 07/070

210

2

1 3

4

5

6

7

8

9

10

11

12

FS 644

01

2

210

2

1 3

4

5

6

7

8

9 11 13 15

10 12 14 16

FS 644

01

2

201

2

1 3

4

5

6

7

8

9 11 13 15

10 12 14 16

FS 684

01 2

2

2101

2

1 3

4

5

6

7

8

9 11

10 12

13

14

15 17 19

16 18 20

21

22

23

24

FS 629

10

12 2

FS 441

10

12 2

07/034 07/035

Page 25: 07/000 T Rotary Switches, P Switch-Disconnectors · Moeller HPL0211-2001/2002 T Rotary Switches, P Switch-Disconnectors Overview of Functions Rotary Switches Switch-Disconnectors

Moeller HPL0211-2001/2002

T Rotary SwitchesControl Switches: Step Switches

Rota

ry S

witc

hes

Swit

ch-D

isco

nnec

tors

Rota

ry S

wit

ches

Swit

ch-D

isco

nnec

tors

Moeller HPL0211-2001/2002

T Rotary SwitchesControl Switches: Step Switches

Circuit diagram Front plate no.

No. of poles

Steps Flush mountingFront IP65

Centre mountingFront IP65

Surface mounting 2) IP65

Service distribution board mountingFront IP30

Rear mountingFront IP65

Notes

Basic typeFor ... insert mounting form

Mounting formArticle no.

PriceSee Price List

Mounting formArticle no.

PriceSee Price List

Mounting formArticle no.

PriceSee Price List

Mounting formArticle no.

PriceSee Price List

Mounting formArticle no.

PriceSee Price List

Step switches1)

One contact closed per step(without overlap)With additional 0 (Off) position

1 2 T0-1-8240/... E034105

EZ043597

I1207079

IVS027076

Z060208

Suitable for actuating electronic devicesRated uninterrupted current

Iu 20 ARated operational current

Ie AC-15220 – 240 V 6 A380 – 415 V 4 AAC-21A 12 ADC-13 32 V per contact 10 A

Additional Technical Data

a Page 07/090

1 3 T0-2-8241/... E050716

EZ053089

I1207107

IVS057835

Z062581

1 4 T0-2-8242/... E067327

EZ069700

I1207108

IVS074446

Z076819

1 5 T0-3-8243/... E081565

EZ083938

I1207128

IVS088684

Z091057

1 6 T0-3-8244/... E095803

EZ098176

I1207129

IVS012749

Z015122

3 2 T0-3-8280/... E034106

EZ036479

I1207130

IVS041225

Z043598

3 3 T0-5-8281/... E048344

EZ050717

– IVS055463

Z057836

3 4 T0-6-8282/... E062582

EZ064955

– IVS069701

Z072074

Standard pack: 1 off Standard pack: 1 off

Notes 1) With black thumb-grip and grey front plate2) Enclosure designed for metric cable glands to EN 50 262, cable glands

a Page 07/070

2

1 3

4

FS 418

21

0

210

3210

2

1 3

4

5

6

FS 420

21

03

3210

4

2

1 3

4

5

6

7

8

FS 422

21

034

3210

45

2

1 3

4

5

6

7

8

9

10

FS 424

21

034

5

3210

456

2

1 3

4

5

6

7

8

11

1210

9

FS 426

21

034

65

210

2

1 3

4

5

6

7

8

9

10

11

12

FS 418

21

0

210

3

2

1 3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

FS 420

21

03

210

34

2

1 3

4

5

6

7

8

9

10

11 13 15

12 14 16

17 19

18 20

21

22

23

24

FS 422

21

034

07/036 07/037

Page 26: 07/000 T Rotary Switches, P Switch-Disconnectors · Moeller HPL0211-2001/2002 T Rotary Switches, P Switch-Disconnectors Overview of Functions Rotary Switches Switch-Disconnectors

Moeller HPL0211-2001/2002

T Rotary SwitchesControl Switches: Step Switches

Rota

ry S

witc

hes

Swit

ch-D

isco

nnec

tors

Rota

ry S

wit

ches

Swit

ch-D

isco

nnec

tors

Moeller HPL0211-2001/2002

T Rotary SwitchesControl Switches: Step Switches

Circuit diagram Front plate no.

No. of poles

Steps Flush mountingFront IP65

Centre mountingFront IP65

Surface mounting 2) IP65

Service distribution board mountingFront IP30

Rear mountingFront IP65

Notes

Basic typeFor ... insert mounting form

Mounting formArticle no.

PriceSee Price List

Mounting formArticle no.

PriceSee Price List

Mounting formArticle no.

PriceSee Price List

Mounting formArticle no.

PriceSee Price List

Mounting formArticle no.

PriceSee Price List

Step switches1)

One contact closed per step(without overlap)Without 0 (Off) position

1 2 T0-1-8220/... E031728

EZ095799

I1207078

IVS055459

Z086312

Suitable for actuating electronic devicesRated uninterrupted current

Iu 20 ARated operational current

Ie AC-15220 – 240 V 6 A380 – 415 V 4 AAC-21A 12 ADC-13 32 V per contact 10 A

Additional Technical Data

a Page 07/090

1 3 T0-2-8230/... E088685

EZ091058

I1207105

IVS095804

Z098177

1 4 T0-2-8231/... E012750

EZ015123

I1207106

IVS019869

Z022242

1 5 T0-3-8232/... E026988

EZ029361

I1207126

IVS034107

Z036480

1 6 T0-3-8233/... E041226

EZ043599

I1207127

IVS048345

Z050718

3 2 T0-3-8222/... E048339

EZ015118

I1207124

IVS060205

Z088686

3 3 T0-5-8270/... E091059

EZ093432

– IVS098178

Z010378

3 4 T0-6-8271/... E015124

EZ017497

– IVS022243

Z024616

Standard pack: 1 off Standard pack: 1 off

Notes 1) With black thumb-grip and grey front plate2) Enclosure designed for metric cable glands to EN 50 262, cable glands

a Page 07/070

12

2

1 3

4

FS 943

1 2

321

2

1 3

4

5

6

FS 404

32

1

321

4

2

1 3

4

5

6

7

8

FS 606

2

41

3

321

45

2

1 3

4

5

6

7

8

9

10

FS 408

32 4

51

321

456

2

1 3

4

5

6

7

8

9

10

11

12

FS 410

32 4

516

12

2

1 3

4

5

6

7

8

9

10

11

12

FS 943

1 2

321

2

1 3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

FS 404

32

1

21

34

2

1 3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22

23

24

FS 406

23

14

07/038 07/039

Page 27: 07/000 T Rotary Switches, P Switch-Disconnectors · Moeller HPL0211-2001/2002 T Rotary Switches, P Switch-Disconnectors Overview of Functions Rotary Switches Switch-Disconnectors

Moeller HPL0211-2001/2002

T Rotary SwitchesControl Switches: On-Off Switches, Changeover Switches

Rota

ry S

witc

hes

Swit

ch-D

isco

nnec

tors

Rota

ry S

wit

ches

Swit

ch-D

isco

nnec

tors

Moeller HPL0211-2001/2002

T Rotary SwitchesControl Switches: On-Off Switches, Changeover Switches

Circuit diagram Front plateno.

No. of poles

Flush mountingFront IP65

Centre mountingFront IP65

Surface mounting 2) IP65

Service distribution board mountingFront IP30

Rear mountingFront IP65

Notes

Basic typeFor ... insert mounting form

Mounting formArticle no.

PriceSee Price List

Mounting formArticle no.

PriceSee Price List

Mounting formArticle no.

PriceSee Price List

Mounting formArticle no.

PriceSee Price List

Mounting formArticle no.

PriceSee Price List

On-Off switches1)

1 T0-1-15401/... E038854

EZ041227

I1207067

IVS045973

Z048346

Suitable for actuating electronic devicesRated uninterrupted current

Iu 20 ARated operational current

Ie AC-15220 – 240 V 6 A380 – 415 V 4 AAC-21A 12 ADC-13 32 V per contact 10 A

Additional Technical Data

a Page 07/090

2 T0-1-15402/... E053092

EZ055465

I1207068

IVS060211

Z062584

3 T0-2-15403/... E067330

EZ069703

I1207088

IVS074449

Z076822

4 T0-2-15404/... E081568

EZ083941

I1207089

IVS088687

Z091060

Changeover switches1)

1 T0-1-15421/... E095806

EZ098179

I1207069

IVS012752

Z015125

2 T0-2-15422/... E019871

EZ022244

I1207090

IVS026990

Z029363

3 T0-3-15423/... E034109

EZ036482

I1207114

IVS041228

Z043601

Standard pack: 1 off Standard pack: 1 off

Notes 1) With black thumb-grip and grey front plate2) Enclosure designed for metric cable glands to EN 50 262, cable glands

a Page 07/070

01

2

1

FS 415

01

01

2

1

4

3

FS 415

01

01

2

1 3

4

5

6

FS 415

01

01

2

1 3

4

5

6

7

8

FS 415

01

102

2

1 3

4

FS 429

02 1

102

2

1 3

4

5

6

7

8

FS 429

02 1

102

2

1 3

4

5

6

7

8

9

10

11

12

FS 429

02 1

07/040 07/041

Page 28: 07/000 T Rotary Switches, P Switch-Disconnectors · Moeller HPL0211-2001/2002 T Rotary Switches, P Switch-Disconnectors Overview of Functions Rotary Switches Switch-Disconnectors

Moeller HPL0211-2001/2002

T Rotary SwitchesControl Switches: Hand/Auto Switches

Rota

ry S

witc

hes

Swit

ch-D

isco

nnec

tors

Rota

ry S

wit

ches

Swit

ch-D

isco

nnec

tors

Moeller HPL0211-2001/2002

T Rotary SwitchesControl Switches: Hand/Auto Switches

Circuit diagram Front plateno.

No. of poles

Flush mountingFront IP65

Centre mountingFront IP65

Surface mounting 2) IP65

Service distribution board mountingFront IP30

Rear mountingFront IP65

Notes

Basic typeFor ... insert mounting form

Mounting formArticle no.

PriceSee Price List

Mounting formArticle no.

PriceSee Price List

Mounting formArticle no.

PriceSee Price List

Mounting formArticle no.

PriceSee Price List

Mounting formArticle no.

PriceSee Price List

Hand/Auto switches1)

Hand/Auto switches with locking arrangement

a Page 07/052With 0 (Off) position

1 T0-1-15431/... E019872

EZ022245

I1207070

IVS026991

Z029364

Suitable for actuating electronic devicesRated uninterrupted current

Iu 20 ARated operational current

Ie AC-15220 – 240 V 6 A380 – 415 V 4 AAC-21A 12 ADC-13 32 V per contact 10 A

Additional Technical Data

a Page 07/090

2 T0-2-15432/... E034110

EZ036483

I1207091

IVS041229

Z043602

3 T0-3-15433/... E048348

EZ050721

I1207115

IVS055467

Z057840

With spring-return from HAND1 T0-1-15434/... E

062586EZ018053

I1207071

IVS069705

Z072078

2 T0-2-15435/... E003191

EZ003192

I1218971

IVS003195

Z003196

With spring-return from START1 T0-2-15907/... E

066931EZ069304

I1207095

IVS076423

Z078796

Without 0 (Off) position1 T0-1-15451/... E

076824EZ079197

I1207072

IVS083943

Z086316

2 T0-2-15452/... E091062

EZ093435

I1207092

IVS098181

Z010381

3 T0-3-15453/... E015127

EZ017500

I1207116

IVS022246

Z024619

Standard pack: 1 off Standard pack: 1 off

Notes 1) With black thumb-grip and grey front plate2) Enclosure designed for metric cable glands to EN 50 262, cable glands

a Page 07/070

0AUTO

HAND

2

1 3

4

FS 1401

0HAND AUTO

0AUTO

HAND

2

1 3

4

5

6

7

8

FS 1401

0HAND AUTO

0AUTO

HAND

2

1 3

4

5

6

7

8

9

10

11

12

FS 1401

0HAND AUTO

0HAND

AUTO

2

1 3

4

FS 1414000

0HAND AUTO

0AUTO

HAND

2

1 3

4

5

6

7

8

FS 1414000

0HAND AUTO

0AUTO

STARTHAND

2

1 3

4

5

6

7

8

FS 1413890

0AUTO HAND

START

HANDAUTO

2

1 3

4

FS 19334

HAND AUTO

HANDAUTO

2

1 3

4

5

6

7

8

FS 19334

HAND AUTO

HANDAUTO

2

1 3

4

5

6

7

8

9

10

11

12

FS 19334

HAND AUTO

07/042 07/043

Page 29: 07/000 T Rotary Switches, P Switch-Disconnectors · Moeller HPL0211-2001/2002 T Rotary Switches, P Switch-Disconnectors Overview of Functions Rotary Switches Switch-Disconnectors

Moeller HPL0211-2001/2002

T Rotary SwitchesControl Switches: Spring-Return Switches

Rota

ry S

witc

hes

Swit

ch-D

isco

nnec

tors

Rota

ry S

wit

ches

Swit

ch-D

isco

nnec

tors

Moeller HPL0211-2001/2002

T Rotary SwitchesControl Switches: Spring-Return Switches

Circuit diagram Front plateno.

No. of poles

Flush mountingFront IP65

Centre mountingFront IP65

Surface mounting 2) IP65

Service distribution board mountingFront IP30

Rear mountingFront IP65

Notes

Basic typeFor ... insert mounting form

Mounting formArticle no.

PriceSee Price List

Mounting formArticle no.

PriceSee Price List

Mounting formArticle no.

PriceSee Price List

Mounting formArticle no.

PriceSee Price List

Mounting formArticle no.

PriceSee Price List

On-switch (make contact)1)

Spring-return from position 11 T0-1-15321/... E

086317EZ088690

I1207064

IVS093436

Z095809

Suitable for actuating electronic devicesRated uninterrupted current

Iu 20 ARated operational current

Ie AC-15220 – 240 V 6 A380 – 415 V 4 AAC-21A 12 ADC-13 32 V per contact 10 A

Additional Technical Data

a Page 07/090

2 T0-1-15322/... E010382

EZ012755

I1207065

IVS017501

Z019874

3 T0-2-15323/... E024620

EZ026993

I1207087

IVS031739

Z034112

On-Off switch1)

Spring-return from positions 0 and 11 T0-1-15366/... E

081572EZ083945

I1207066

IVS088691

Z091064

On-Off switch1)

Spring-return from START1 T0-1-15511/... E

019875EZ022248

I1207073

IVS026994

Z029367

2 T0-2-15512/... E034113

EZ036486

I1207093

IVS041232

Z043605

3 T0-3-15513/... E048351

EZ050724

I1207117

IVS055470

Z057843

See K115 T0-2-8177/... E015130

EZ017503

I1207101

IVS022249

Z024622

Standard pack: 1 off Standard pack: 1 off

Notes 1) With black thumb-grip and grey front plate2) Enclosure designed for metric cable glands to EN 50 262, cable glands

a Page 07/070

1

2

1

FS 4721

1

1

2

1

4

3

FS 4721

1

1

2

1 3

4

5

6

FS 4721

1

1

0

2

1 3

4

FS 456

0 1

10

START

2

1 3

4

FS 147767

START

1

0

10

START

2

1 3

4

5

6

7

8

FS 147767

START

1

0

10

START

2

1 3

4

5

6

7

8

9

10

11

12

FS 147767

START

1

0

2

10

START

START

2

1 3

4

5

6

7

8

FS 140660

01 2

START START

07/044 07/045

Page 30: 07/000 T Rotary Switches, P Switch-Disconnectors · Moeller HPL0211-2001/2002 T Rotary Switches, P Switch-Disconnectors Overview of Functions Rotary Switches Switch-Disconnectors

Moeller HPL0211-2001/2002

T Rotary SwitchesControl Switches: Universal Control Switches, Coding Switches, Series Switches

Rota

ry S

witc

hes

Swit

ch-D

isco

nnec

tors

Rota

ry S

wit

ches

Swit

ch-D

isco

nnec

tors

Moeller HPL0211-2001/2002

T Rotary SwitchesControl Switches: Universal Control Switches, Coding Switches, Series Switches

Circuit diagram Front plateno.

No. of poles

Flush mountingFront IP65

Centre mountingFront IP65

Surface mounting 2) IP65

Service distribution board mountingFront IP30

Rear mountingFront IP65

Notes

Basic typeFor ... insert mounting form

Mounting formArticle no.

PriceSee Price List

Mounting formArticle no.

PriceSee Price List

Mounting formArticle no.

PriceSee Price List

Mounting formArticle no.

PriceSee Price List

Mounting formArticle no.

PriceSee Price List

Universal control switches1)

Stay-put switches with 3 positions1 contact closed in each position; in addition:1 contact closed in positions 0 and 1 1 contact closed in positions 0 and 2 1 contact closed in positions 1 and 2

– T0-3-15391/... E029365

EZ031738

I1207112

IVS036484

Z038857

Suitable for actuating electronic devicesRated uninterrupted current

Iu 20 ARated operational current

Ie AC-15220 – 240 V 6 A380 – 415 V 4 AAC-21A 12 ADC-13 32 V per contact 10 A

Additional Technical Data

a Page 07/090

As above, but with spring-return from positions 1 and 2– T0-3-15394/... E

072079EZ074452

I1207113

IVS079198

Z081571

Coding switches1)

With complete rotation in both directionsDual BCD CODE

T0-4-15602/... E029368

EZ031741

I1207134

IVS036487

Z038860

Series switches1)

With 0 (Off) position(heater switches)

1 T0-1-91/... E072082

EZ074455

I1207080

IVS079201

Z081574

Standard pack: 1 off Standard pack: 1 off

Notes 1) With black thumb-grip and grey front plate2) Enclosure designed for metric cable glands to EN 50 262, cable glands

a Page 07/070

201

2

1 3

4

5

6

7

8

9

10 12

11

FS 429

02 1

201

2

1 3

4

5

6

7

8

9

10 12

11

FS 458

012

9876543210

2

1 3

4

5

6

7

8

9 11 13 15

10 12 14 16

42

0

3

9

6

8

1 5

7

FS 312

210

2

1

4

3

FS 614

0

21

07/046 07/047

Page 31: 07/000 T Rotary Switches, P Switch-Disconnectors · Moeller HPL0211-2001/2002 T Rotary Switches, P Switch-Disconnectors Overview of Functions Rotary Switches Switch-Disconnectors

Moeller HPL0211-2001/2002

T Rotary SwitchesControl Switches: Instrument Selector Switches

Rota

ry S

witc

hes

Swit

ch-D

isco

nnec

tors

Rota

ry S

wit

ches

Swit

ch-D

isco

nnec

tors

Moeller HPL0211-2001/2002

T Rotary SwitchesControl Switches: Instrument Selector Switches

Circuit diagram Front plateno.

No. of poles Flush mountingFront IP65

Centre mountingFront IP65

Surface mounting 2) IP65

Service distribution board mountingFront IP30

Rear mountingFront IP65

Notes

Basic typeFor ... insert mounting form

Mounting formArticle no.

PriceSee Price List

Mounting formArticle no.

PriceSee Price List

Mounting formArticle no.

PriceSee Price List

Mounting formArticle no.

PriceSee Price List

Mounting formArticle no.

PriceSee Price List

Voltmeter selector switches1)

3

x phase to phase with 0 (Off) position

T0-2-15920/... E038861

EZ041234

I1207098

IVS029452

Z048353

Suitable for actuating electronic devicesRated uninterrupted current

Iu 20 ARated operational current

Ie AC-15220 – 240 V 6 A380 – 415 V 4 AAC-21A 12 ADC-13 32 V per contact 10 A

Additional Technical Data

a Page 07/090

3

x phase to phase without 0 (Off) position

T0-2-15922/... E053099

EZ055472

I1207100

IVS060218

Z062591

3

x phase to N with 0 (Off) position

T0-2-15921/... E067337

EZ069710

I1207099

IVS074456

Z076829

3

x phase to phase + 3

xphase to N with 0 (Off) position

T0-3-8007/... E095813

EZ098186

I1207120

IVS012759

Z015132

3

x phase to phase + 3

x phase to N without 0 position with complete rotation in both directions

T0-3-15924/... E019878

EZ022251

I1207119

IVS026997

Z029370

Ammeter selector switches1)

With complete rotation in both directionsMeasurement via current transformers

With 0 (Off) position T0-3-8048/... E034116

EZ036489

I1207122

IVS041235

Z043608

Voltmeter and ammeter selector switches1)

With complete rotation in both directionsMeasurement via current transformers(For other circuits

a catalogue K115)With 0 (Off) position T0-3-8030/... E

013401EZ013402

I1207121

IVS013404

Z013406

Standard pack: 1 off Standard pack: 1 off

Notes 1) With black thumb-grip and grey front plate2) Enclosure designed for metric cable glands to EN 50 262, cable glands

a Page 07/070

0

L3+L1L2+L3L1+L2

2

1 3

4

5

6

7

8

L1-L2L2-L3

L3-L10

FS 1410755

L3-L1L2-L3L1-L2

2

1 3

4

5

6

7

8

L1-L2L2-L3

L3-L1

FS 164854

0

L3-NL2-NL1-N

2

1 3

4

5

6

7

8L1-N

L2-NL3-N

FS 1410757

0

0

L3-NL2-NL1-N

L1-L2L2-L3L3-L1

2

1 3

4

5

6

7

8

9 11

10 12

L1-L2

FS 1410759

0

L2-L3

L3-L1

L1-N

L2-N

L3-N

L3-NL2-NL1-NL3-L1L2-L3L1-L2

2

1 3

4

5

6

7

8

9 11

10 12

L1-L2L2-L3

L3-L1

L1-NL2-N

L3-N

FS 164721

0

L3L2L1

2

1 3

4

5

6

7

8

9

10 12

11 L1

L2

FS 9440

0

L3

0

201

2

1 3

4

5

6

7

8

9

10 12

11

FS 928

1

2

0 0

07/048 07/049

Page 32: 07/000 T Rotary Switches, P Switch-Disconnectors · Moeller HPL0211-2001/2002 T Rotary Switches, P Switch-Disconnectors Overview of Functions Rotary Switches Switch-Disconnectors

Moeller HPL0211-2001/2002

T Rotary Switches, P Switch-DisconnectorsSwitches with Locking Arrangements

Rota

ry S

witc

hes

Swit

ch-D

isco

nnec

tors

Rota

ry S

wit

ches

Swit

ch-D

isco

nnec

tors

Moeller HPL0211-2001/2002

T Rotary Switches, P Switch-DisconnectorsSwitches with Locking Arrangements

Circuit diagram

Front plateno.

No. of poles

Max. three-phasemotor rating (per set of 3 contacts)50–60 Hz

Rated uninter-rupted current

Flush mountingIP65

Surface mounting 3) IP65

Rear mountingIP65

Notes

AC-3220 V230 V240 V

380 V400 V440 V

660 V690 V

Iu TypeArticle no.

PriceSee Price List

TypeArticle no.

PriceSee Price List

TypeArticle no.

PriceSee Price ListkW kW kW A Std. pack

Switches with locking arrangements, KMS1 lock mechanismPanic switches without Emergency-Stop function1)

With SVA cylinder lock Key withdrawable in positions 0 and 1 When the key is withdrawn in position 1, the switchcan still be switched Off, but cannot be switched back On again without the key

3 3 4 4 20 T0-2-1/E/SVA(S)050977

T0-2-1/I1/SVA(S)207084

– 1 off

Code letters for lockable switch positionsLetter S for panic lock with FS908GE

4 5.5 7.5 25 P1-25/E/SVA(S)050966

P1-25/I2/SVA(S)207305

5.5 11 15 32 P1-32/E/SVA(S)044977

P1-32/I2/SVA(S)207326

5.5 11 15 32 T3-2-1/E/SVA(S)050983

T3-2-1/I2/SVA(S)207173

On-Off switch without Emergency-Stop function1)

With SVA cylinder lockKey withdrawable in 0 position only (code letter A)

3 3 4 4 20 T0-2-1/E/SVA(A)050976

T0-2-1/I1/SVA(A)207083

T0-2-1/Z/SVA(A)050978

4 5.5 7.5 25 P1-25/E/SVA(A)050965

P1-25/I2/SVA(A)207304

P1-25/Z/SVA(A)050969

5.5 11 15 32 P1-32/E/SVA(A)050970

P1-32/I2/SVA(A)207325

P1-32/Z/SVA(A)050973

5.5 11 15 32 T3-2-1/E/SVA(A)050982

T3-2-1/I2/SVA(A)207172

T3-2-1/Z/SVA(A)050984

Panic switches with Emergency-Stop function2)

With SVA cylinder lockKey withdrawable in positions 0 and 1 When the key is withdrawn in position 1, the switchcan still be switched Off, but cannot be switched back On again without the key

3 3 4 4 20 T0-2-1/E/SVA(S)-RT228971

T0-2-1/I1/SVA(S)-RT207085

4 5.5 7.5 25 P1-25/E/SVA(S)-RT050967

P1-25/I2/SVA(S)-RT207306

5.5 11 15 32 P1-32/E/SVA(S)-RT050971

P1-32/I2/SVA(S)-RT207327

5.5 11 15 32 T3-2-1/E/SVA(S)-RT044972

T3-2-1/I2/SVA(S)-RT207174

Panic switches with Emergency-Stop function2)

With SVC padlocking feature Locking slide can be padlocked in positions 0 and 1. When the locking slide is padlocked in position 1, the switch can still be switched Off, but cannot be switched back On again without first removing the padlock. Lockable using up to 3 padlocks.

3 3 4 4 20 T0-2-1/E/SVC(S)-RT044973

T0-2-1/I1/SVC(S)-RT207086

4 5.5 7.5 25 P1-25/E/SVC(S)-RT044974

P1-25/I2/SVC(S)-RT207307

5.5 11 15 32 P1-32/E/SVC(S)-RT044975

P1-32/I2/SVC(S)RT207328

5.5 11 15 32 T3-2-1/E/SVC(S)-RT044976

T3-2-1/I2/SVC(S)-RT207175

On-Off switches without Emergency-Stop function1)

With S-T0 key operation Key withdrawable in position 0 only (code letter A)

2 2.2 2.2 – 20 T0-1-102/EZ/S014933

4) T0-1-102/I1/S207063

T0-1-102/Z/S014971

Notes 1) With black thumb-grip and grey front plate2) To IEC/EN 60204-1; with red thumb-grip and yellow front plate

3) Enclosure designed for metric cable glands to EN 50 262, cable glands

a Page 07/0704) Degree of protection IP53

1 3 5

2 4 6

FS 908

ON

OFF

330 0 30

300

240225

210180

150

135120

90

6045

270

F

HG

J

KL

MN

PQ

R

A

BC

DE

315

1 3 5

2 4 6

FS 908

ON

OFF

1 3 5

2 4 6

FS 908 GE

1

0

1 3 5

2 4 6

FS 908 GE

1

0

1

2

3

4

FS 908

ON

OFF

07/050 07/051

Page 33: 07/000 T Rotary Switches, P Switch-Disconnectors · Moeller HPL0211-2001/2002 T Rotary Switches, P Switch-Disconnectors Overview of Functions Rotary Switches Switch-Disconnectors

Moeller HPL0211-2001/2002

T Rotary SwitchesSwitches with Locking Arrangements

Rota

ry S

witc

hes

Swit

ch-D

isco

nnec

tors

Rota

ry S

wit

ches

Swit

ch-D

isco

nnec

tors

Moeller HPL0211-2001/2002

T Rotary SwitchesSwitches with Locking Arrangements

Circuit diagram

Front plateno.

Rated uninter-rupted current

Flush mountingFront IP65

Surface mounting1) IP65

Rear mountingFront IP65

Notes

Iu TypeArticle no.

PriceSee Price List

TypeArticle no.

PriceSee Price List

TypeArticle no.

PriceSee Price ListA Std. pack

Switches with locking arrangements, KMS1 lock mechanismHand/Auto switches with SVA cylinder lock

Suitable for actuating electronic devicesRated uninterrupted current

Iu 20 ARated operational current

Ie AC-15220 – 240 V 6 A380 – 415 V 4 AAC-21A 12 ADC-13 32 V per contact 10 A

Additional Technical Data

a Page 07/090

Rotary switches with an SVA locking arrangement can also be used as Operating Mode Selector Switches for the purposes of EU Machine Directive 89/392 (Minimum switching angle: 60°)

Code letters for lockable switch positions

Key withdrawable in all positionsWhen the key is withdrawn in the HAND position, then START can be actuated without first removing the padlock, but not position 0(only admissible with separate Off switch)

20 T0-2-15907/E/SVA(C,E,G-J)050979

T0-2-15907/I1/SVA(C,E,G-J)207096

– 1 off

32 T3-2-15907/E/SVA(C,E,G-J)050985

T3-2-15907/I2/SVA(C,E,G-J)207176

Hand/Auto switches with SVC padlocking feature

Locking slide can be padlocked in all positions.When the locking slide is padlocked in the HAND position, then START can be actuated without the key,but not position 0 (only admissible with separate Off switch)

20 T0-2-15907/E/SVC(C,E,G-J)044996

T0-2-15907/I1/SVC(C,E,G-J)207097

T0-2-15907/Z/SVC(C,E,G-J)050980

32 T3-2-15907/E/SVC(C,E,G-J)044997

T3-2-15907/I2/SVC(C,E,G-J)207177

T3-2-15907/Z/SVC(C,E,G-J)050986

Notes 1) Enclosure designed for metric cable glands to EN 50 262, cable glands

a Page 07/070Contactor interlocking circuitsControl section for standard contactor interlocking circuits.If a standard switch is to contain one of the contactor interlocking circuits as well, it can be ordered using another circuit number from catalogue K115, or as a non-standard switch.

The electrical interlocking of rotary switch and contactor makes possible a wide range of control functions.For example: remote disconnection via a stop switch, overload protection via overload relays, protection against automatic restarting after a power failure or overload, and Off position interlocking, etc.

SOND 27 SOND 28 SOND 29 SOND 30

Mains disconnection only by contactor.Restarting possible only with the rotary switch in the Off position.Application: primarily for star-delta circuits (only at 60 or 90° switching angles)

Mains disconnection by contactor and rotary switch together Restarting: as SOND 27 Application: primarily for star-delta and changeover circuits (only at 60 or 90° switching angles)

Mains connection by contactor, only with the rotary switch in the Off position (Off position interlock)Application: star-delta, changeover and multi-speed circuits

Mains connection by contactor, only with the rotary switch in a run position Each change in the switch position causes the contactor to drop out Application: changeover and multi-speed circuits

330 0 30

300

240225

210180

150

135120

90

6045

270

F

HG

J

KL

MN

PQ

R

A

BC

DE

315

0AUTO

STARTHAND

2

1 3

4

5

6

7

8

FS 1413890

0AUTO HAND

START

0AUTO

STARTHAND

2

1 3

4

5

6

7

8

FS 1413890

0AUTO HAND

START

F0

F2

S0

K1M

K1M

Q1

0 21

M3~

K1M

ControlsectionSOND 27

Powersectionwithoutmainsdisconnection

Contactsequence asrequired

F0

F2

S0

K1M

K1M

Q1

0 1 2

M3~

KM1

ControlsectionSOND 28

Powersectionwithmainsdisconnection

Contactsequence asrequired

K1M

F0

F2

K1M

K1M

S1

Q1

0 1 2

M3~

S0Control sectionSOND 29

Powersection

Contactsequence as required

K1M

F0

F2

S0

K1M

K1M

S1

Q1

10 2

M3~

Control sectionSOND 30

Powersection

Contactsequence as required

07/052 07/053

Page 34: 07/000 T Rotary Switches, P Switch-Disconnectors · Moeller HPL0211-2001/2002 T Rotary Switches, P Switch-Disconnectors Overview of Functions Rotary Switches Switch-Disconnectors

Moeller HPL0211-2001/2002

T Rotary Switches, P Switch-DisconnectorsFront Plates

Rota

ry S

witc

hes

Swit

ch-D

isco

nnec

tors

Rota

ry S

wit

ches

Swit

ch-D

isco

nnec

tors

Moeller HPL0211-2001/2002

T Rotary Switches, P Switch-DisconnectorsFront Plates

Standard front plates Emergency-Stop front plates Blank plates Non-standard front plates Non-standard front platesSwitch size Dimensions Yellow Can be engraved

TypeArticle no.

PriceSee Price List

Std. pack TypeArticle no.

PriceSee Price List

Std. pack TypeArticle no.

PriceSee Price List

Std. pack TypeArticle no.

PriceSee Price List

Std. pack Height of letters

mm

State the front plate no. required

F 2 characters

mm

> 2 characters

mm

Standard Front platesT0, T3, P1 45

x 45 (for frame size 48

x 48)FS...-T0903197

10 off FS908 GE-T0003198

5 off FS980-T0003199

50 off FS-SOND-ERSTBESTELLUNG-T01)

2253555 off 4 3

P3, T5, T5B 84

x 84 (for frame size 88

x 88)FS...-P3995545

10 off FS908 GE-P3031475

5 off FS980-P3043340

50 off FS-SOND-ERSTBESTELLUNG-P32)

2253565 off 8 5

TM 29

x 29 (for frame size 30

x30 )– – FS980-TM-E

07143810 off FS-SOND-TM-E

0928295 off 3.5 2.5

– – FS980-TM-EZ073811

50 off FS-SOND-TM-EZ095202

5 off 3.5 2.5

1) = first order; for subsequent orders use FS...-T02) = first order; for subsequent orders use FS...-P3

Standard front plates Non-standard front platesThe standard front plates illustrated should be used for non-standard switches where possible. Standard catalogue front plates for standard switches can be exchanged on request with order, for those illustrated here, at no extra charge (not applicable to T6, T8 and TM), provided the switching angles, the number of switch positions, and the location of the 0 (Off) position match.Example: T0-1-8210/E+FS161570

Inscription to order (note maximum number of characters per field).The FS number is sufficient for reordering.For non-standard T0, T3 and T5(B) switches, the front plate is included in the price.For standard switches, the front plate is included in the price for orders exceeding 49 off.

a Page 07/113Switching angle 90°

Switching angle 60° Standard front platesarranged in their numerical sequence:

Switching angle 45°

Switching angle 30 °

1

0

HEIZUNG-NOTSCHALTER

AUS

EIN

STOP

ON OFF

EIN START AUTO ZU SLOW

ZU

OFF

AUS STOP HAND AUF ABAUF DOWNUP FAST

AUTO

AUF

AUS

L3

L2

L1

908

0

1

9508

2

1

902 190719

1

193935

0

1

907

0 1

945 1992

1 2

943 19334 190550 19143 193975 190431

192219589

0

T R

S

935

0

9440

2

1 3

4

906

1

0 2

3

912

1+2

1

0

2

1938409441

0

0

1 2

1

2 2

1

923

1

2

0 0

9281921911957

1

0 0

1

926

2

1 3

904

21

192190

0

1 2

953

0 2

1

910

190334

L3

L2

L1

OFF

ONON ONOFFOFF OFF

ON

OFF

ON

OFF

911

13

0

2

START

RUN

STOPSTART

RUN

SLOW

FAST

STOPSLOW

FAST

STOPAUTOSLOWHAND

FAST STOPSTART

RUN NETZAUF

HALTNOT-STROM

AB AUF AB

HALTHALTLINKS RECHTS

AUTO

AUS

HAND AUTO

AUS

HAND AUTO

OFF

HAND

OFF

L2-N L2-L3AUTO

OFFMAN REV.

OFFFORW.

STOPSLOW FAST REV.

STOPFORW. L1-N L3-N

01

611

12

601 1601

01

2

644 16052 635

Y0

16616 684

01 2

621

012

161629

0

161570

0

161359 161358 1610 1614 1673 1617

2 1

6034

0 Y

606

2

41

3

160772616

1

0

2

3

604

2

1

3

614

0

21

164854164855655

21 3

1665166216281627

01

164222

2

1

3

4

0

667 645

2

13

4

0

629

10

12 2

161002 638

Y0

Y

161683

1

0

2

3

4

618 620

1

0

2

345

610

2

1

3

4

56

640

2

10

0

2

1

Y0

0Y

6010 164721 661

L1-L2 L3-L1HIGHOFF

MED.LOW

S-TT-R

R-O

R-S

T-OS-O

L2-L3L3-L1L1-L2

L3-N L1-NL2-N

START

301

12

3 4 567

891011

12

310

12 3 4

56

78910

110

302

12

3 4 5 67

891011

311

12 3 4

56

78910

0

303

12

3 4 567

8910

312

42

0

3

9

6

8

1 5

7

304

12

3 4 567

89

313

12 3 4 5

67

8

0

305

12

3 4 567

8

314

12 3 4

56

70

315

12 3 4

560

307

12

3 4 56

316

12 3 4

50

308

12

3 4 5

317

12 3 4

0

309

12

3 4

408

32 4

51

414

21

345

687

428

0

21 3

4567

412

32

1

7 65

4

426

21

034

65

410

32 4

516

424

21

034

5

422

21

034

406

23

14

420

21

03

404

32

1

418

21

0

429

02 1

01

415

12

402 416

01

610

2

1

3

4

56

614

0

21

604

2

1

3

616

1

0

2

3

606

2

41

312

601

01

611496

1 2

453

23 1

4

0

449

0

211

233

459

21

0

21

456

0 1

458

012

462

21

0

461

01

2

455

10

2

1 3

904

2

1 3

4

906

0

1

907

2

1

902640

2

10

0

2

1

620

1

0

2

345

638

Y0

Y

635

Y0

621

012

629

10

12 2

01

2

644 645

2

13

4

0

655

21 3

661

2

1

3

4

0

667 684

01 2

14201411

02 1

1409140414031401

0

980

0

1 2

953

0 1

945

1 2

943

0

T R

S

935

1

2

0 0

928

1

0 0

1

926

1

2 2

1

923

0 2

1

910

1423

1

1426

0

1446

0

1475 1601 1610 1614 1617

2 1

1627 1628 1662 1665 1673 1922 1957 1992 4011

01 2

4017

Y0

Y

4026

20

1

4117

20

1

4721

1

4722

1 0

4723

0

Y0

0Y

6010 6034

0 Y0

9440 9441

0

0

1 2 0

1

9508 14195

0

14196

0

14510

1

14712 14944

0

147474

0

147472142074

0

2 1

142003141883141879141538141537140660

01 2

140055

0

41409

1 20

195891933419143166161605214988

0

147479 147767

1

0

160772 161002 161358 161359 161570

0

161629

0

161683

01

164222 164721 164854 164855 190334 190431 190550 1907190

141400014139051413903

0

1413890

0

14107631410759

0

1410758

0

1410757

0

1410756

0

1410755

0

194323194321193975

1

193935

1+2

1

0

2

193840192191

21

192190

S-TT-RR-S

S-OT-O R-O

S-T

T-R R-SS-O

R-OR-SS-O

T-O

HAND AUTO

S-T

T-R

T-O R-O

ZU-RUCK

HALTVOR. LINKS RECHTS

HALT

STARTSTART

AUTOAUS

HAND HAND AUTOOFF

EINAUS

OFF

ONAUTO

HAND

AUS

AUTO

OFF

ON

OFFZU AUF

STARTSTART

STOPFORW. REV.

TRIP CLOSE

AUTO

HAND

HAND HANDAUTO

AUTO

AUSAUSAUTO

OFFOFFOFF OFFMANMAN REV. FORW.

STOPSLOW FAST

AUTOHAND

EINAUS EINAUS LINKS RECHTS LANG-

SAM

AUSSCHNELL

EIN

AUS

STOP START

STOP

START START

FORW. REV.

OFFON

STOP

START

STOP

START

HANDAUTO

HEIZUNG-NOTSCHALTER

STOP

FORW. REV.STARTSTART

START

L3 L1

L2

L3 L1

L2

OFFABAUFSTOP

STARTRUNSTOP

SLOWFAST

ZUAUF

ZUAUF S-T

T-R

R-S R-S

S-T

T-R

STOP START SLOW FASTL2-NL3-NL1-N

L2-L3L3-L1L1-L2

DOWNOFF

UPL2-L3

L3-L1L1-L2L2-N

L3-N

L1-N

L2-L3

L3-L1

L1-L2L2-NL3-N

L1-N

L2-L3

L3-L1

L1-L2L2-N

L3-NL1-NL2-L3

L3-L1

L1-L2L1-L2

L2-NL3-N L1-N

L2-L3L3-L1L1-L2

L2-N

L3-N L1-NL2-L3L3-L1

L1-L2

L1-N

OFF

L2-L3

L3-L1 L1-L2

OFFOFF

ON

LOW

START

OFF

OFF

OFF

ON

L2-N

L3-N

L1-NL2-L3

L3-L1

L1-L2OFF MED.

HIGH

STOPSLOW SLOW

FAST FAST

STOP

LINKS RECHTSHALT

ABAUF

HALT

ABAUFNETZ

NOT-STROM STARTSTART

RUNRUN

STOP

HANDAUTO HAND AUTO HANDOFF

RAISESTART LOWER

AUTO

142010

1

0 START

911

13

0

2

318

12 3

0

441

10

12 2

1

0

2

3

4

618

908

ON

OFF

912

20

1

3

OFFON

STOP

STARTAUTO

HAND

START

STOPAUTOHAND

HAND AUTO AUTOOFF

AUTOAUS

HAND

416

01

12

402

01

415 142003 147472 141883 455

10

142010

1

0

141879 4721

1

4722

1 0

4723

0

496

1 2

41409

1 20

429

02 1

1401

0

1413905

0

14140004117

20

1

462

21

0

4026

20

1

461

01

2

147767

1

0

14153814031404147514201411

4011

01 2

458

012

1426

0

14988

0

147474

0

1413903

0

1446

0

456

0 1

1423

1

14510

1

141537 1413890

0

418

21

0

404

32

1

420

21

03

406

23

14

422

21

034

408

32 4

51

441

10

12 2

453

23 1

4

0

4017

Y0

Y

459

21

0

21

1409

02 1

140660

01 2

14712 142074

0

2 1

424

21

034

5

410

32 4

516

426

21

034

65

412

32

1

7 65

4

449

0

2112

33

428

0

21 3

4567

414

21

345

687

1410757

0

14196

0

1410755

0

14195

0

1410756

0

1410758

0

1410759

0

147479 14944

0

1410763 140055

0

194321 194323

HAND AUTOOFF

LANG-SAM

AUSSCHNELL ZU-

RUCKLINKS RECHTS

HALT HALTVOR.

STOP

STARTFORW. REV. HAND

TRIPEIN CLOSEAUS ZUAUFRAISE LOWER

LINKS RECHTSEINAUS STARTSTOP

STOP

FORW. REV. START

START

AUTO HAND

STARTSTART

START

REV.STOP

START

FORW.

STARTSTARTSTARTSTART

L2-NL3-NL1-N

S-OT-OR-O

L2-L3L3-L1L1-L2

L2-N

L3-N

L1-N

L2-L3

L3-L1

L1-L2S-T

T-RR-S L2-L3L3-L1

L1-L2L2-NL3-NL1-N

L1-N

L1-L2 L2-N

L3-N

L1-NL2-L3

L3-L1

L1-L2OFF OFF

L2-L3

L3-L1

L1-L2

L2-N

L3-N L1-N

OFF OFF

L2-L3

L3-L1

L1-L2

L2-L3

L3-L1 L1-L2S-T

T-R

R-S

S-O

T-O

R-O

S-T

T-R

R-S R-S

S-T

T-R

318

12 3

0

309

12

3 4

317

12 3 4

0

308

123 4 5

316

12 3 4

50

307

12

3 4 56

315

12 3 4

560

314

12 3 4

56

70

305

12

3 4 5678

313

12 3 4 5

67

8

0

304

12

3 4 567

89

312

42

0

3

9

6

8

1 5

7

303

12

3 4 5678

910

311

12 3 4

56

78910

0

302

12

3 4 567

891011

310

12 3 4

56

78910

110

301

12

3 4 567

891011

12

07/054 07/055

Page 35: 07/000 T Rotary Switches, P Switch-Disconnectors · Moeller HPL0211-2001/2002 T Rotary Switches, P Switch-Disconnectors Overview of Functions Rotary Switches Switch-Disconnectors

Moeller HPL0211-2001/2002

T Rotary Switches, P Switch-DisconnectorsAccessories

Rota

ry S

witc

hes

Swit

ch-D

isco

nnec

tors

Rota

ry S

wit

ches

Swit

ch-D

isco

nnec

tors

Moeller HPL0211-2001/2002

T Rotary Switches, P Switch-DisconnectorsAccessories

For use with Type suffix Price Std. pack Type Price Std. pack Type suffix Price Std. pack Type PriceArticle no. See Price

ListArticle no. See Price

ListArticle no. See Price

ListArticle no. See Price

ListStd. pack

When orderedwith basic unit

When ordered separately

When orderedwith basic unit

When ordered separately

Add-on front plates, clip-on

For use with front plates and for padlocking features. They comprise a black label mount and an insert plate.Blank, can be engraved T.../I2/SVB(-SW) and

P.../I2/SVB(-SW) except...I1, 2.../IVS T..., P..., except.../I1, 2, 3 .../IVS

– ZFS60-T0019924

25 off – ZFS60-P3022297

25 off ZFS...-T0 and ZFS...-P3 can be used for any T... and P...switches, as required. Dimensions with frame W

x H = 48

x 17 mmDimensions with frame W

x H = 88

x 27 mm

With inscription: “Main switch - Open only in the Off position“

T.../E, T.../Z, P.../E, P.../Z 61/62 = German/English63 = French64 = Bulgarian65 = Danish66 = Finnish67 = Dutch68 = Italian69 = Greek70 = Norwegian71 = Polish72 = Portuguese73 = Romanian74 = Russian75 = Swedish76 = Serbo-Croat77 = Spanish78 = Czech79 = Turkish80 = Hungarian81 = Afrikaans

+ZFS61/62-T0065740

1off ZFS61/62-T0030170

25 off +ZFS61/62-P3065742

1off ZFS61/62-P3065739

25 off ZFS61/62-... included as standard withT.../EA/SVB, P.../EA/SVBT.../V/SVB, P.../V/SVB+ZFS63-T0

065741ZFS63-T0047424

+ZFS63-P3065743

ZFS63-P3047423

+ZFS64-T0205501

ZFS64-T0205535

+ZFS64-P3205518

ZFS64-P3205552

+ZFS65-T0205502

ZFS65-T0205536

+ZFS65P3205519

ZFS65P3205553

+ZFS66-T0205503

ZFS66-T0205537

+ZFS66-P3205520

ZFS66-P3205554

+ZFS67-T0065744

ZFS67-T0065750

+ZFS67-P3065747

ZFS67-P3065753

+ZFS68-T0065745

ZFS68-T0065751

+ZFS68-P3065748

ZFS68-P3065754

+ZFS69-T0205504

ZFS69-T0205538

+ZFS69-P3205521

ZFS69-P3205555

+ZFS70-T0205505

ZFS70-T0205539

+ZFS70-P3205522

ZFS70-P3205556

+ZFS71-T0205506

ZFS71-T0205540

+ZFS71-P3205523

ZFS71-P3205557

+ZFS72-T0205507

ZFS72-T0205541

+ZFS72-P3205524

ZFS72-P3205558

+ZFS73-T0205508

ZFS73-T0205542

+ZFS73-P3205525

ZFS73-P3205559

+ZFS74-T0205509

ZFS74-T0205543

+ZFS74-P3205526

ZFS74-P3205560

+ZFS75-T0205510

ZFS75-T0205544

+ZFS75-P3205527

ZFS75-P3205561

+ZFS76-T0205511

ZFS76-T0205545

+ZFS76-P3205528

ZFS76-P3205562

+ZFS77-T0065746

ZFS77-T0065752

+ZFS77-P3065749

ZFS77-P3047422

+ZFS78T0205512

ZFS78T0205546

+ZFS78-P3205529

ZFS78-P3205563

+ZFS79-T0205513

ZFS79-T0205547

+ZFS79-P3205530

ZFS79-P3205564

+ZFS80-T0205514

ZFS80-T0205548

+ZFS80-P3205531

ZFS80-P3205565

+ZFS81-T0205515

ZFS81-T0205549

+ZFS81-P3205532

ZFS81-P3205566

Label mounts, blackT.../I2/SVB(-SW) and P.../I2/SVB(-SW) except...I1, 2.../IVS

T..., P..., except.../I1, 2, 3 .../IVS

– ZFSX-T0024670

25 off – ZFSX-P3027043

25 off ZFSX...-T0 and ZFSX...-P3 can be used for any T... and P...switches, as required. ZFSX...-T0: dimensions with frame W

x H = 48

x 17 mmZFSX...-P3: dimensions with frame W

x H = 88

x 27 mm

07/056 07/057

Page 36: 07/000 T Rotary Switches, P Switch-Disconnectors · Moeller HPL0211-2001/2002 T Rotary Switches, P Switch-Disconnectors Overview of Functions Rotary Switches Switch-Disconnectors

Moeller HPL0211-2001/2002

T Rotary Switches, P Switch-DisconnectorsAccessories

Rota

ry S

witc

hes

Swit

ch-D

isco

nnec

tors

Rota

ry S

wit

ches

Swit

ch-D

isco

nnec

tors

Moeller HPL0211-2001/2002

T Rotary Switches, P Switch-DisconnectorsAccessories

For use with Key withdrawal Type suffix Price Key withdrawal Type PriceArticle no. See Price

ListArticle no. See Price

ListStd. pack Notes

When orderedwith basic unit

When ordered separately

S-T0 key operated lock mechanism, Front IP53

Includes two keys

KMS 1 lock mechanismIndividual lock mechanism, not suitable for master key systems

T0-.../E, .../I1, .../Z Up to 6 contact unitsT3-.../E, .../I2, .../Z Up to 5 contact unitsP1-.../E, .../I2, .../Z

Key withdrawal positions are programmed ex-works to match the switch

+S-T0001753

Key withdrawal positions can be programmed by the user

S-T0086709

1 off S-T0 can be used for P1-..., T0-1... to T0-6... and T3-1... to T3-5... switches.The key replaces the thumb-grip. Switching is not possible with-out the key. The switch position indicator is on the lock. In standard applications, the key can be withdrawn in any position, on switches with FS908, only in the Off position. New positions for key withdrawal can be selected (even retrospectively) by fitting VR-T0 locking cams.The switching angle is determined by the switch.When retrofitting the S-T0, use the front plate of the switch.Lock mechanism: standard KMS 1 (CES lock)

SVA-T3 can be fitted to T0, T3 and P1 switches. Switching is carried out using the thumb-grip.The switch is locked by turning the key; the key is withdrawable. In standard applications, all positions are lockable. Lock mechanism: standard KMS 1 (CES lock). Individual positions or ranges can be locked (also with VR-T3 fitted by the user). The key cannot be withdrawn in positions which are not lockable. Where ranges are locked, switching without the key is possible only within a locked range.The lockable positions or ranges are shown below; use the code letters to state your selection on the order:Example 1: SVA(A)-T3 = Only position A lockableExample 2: SVA(A, E)-T3 = Positions A and E lockableExample 3: SVA(A–J)-T3 = Range A to J lockableExample 4: SVA(S)-T3 = Main switches, for use as Emergency-Stop devices to IEC/EN 60 204-1; with red handle and yellow front plate as panic lock version, lockable in positions A and E; switching is still possible from E to A, but not from A to E.When retrofitting the SVA-T3, use the front plate of the switch. With letter S for panic lock, use FS908GE. Ordering example: P1-25/I2-RT+SVA(S)-T3.

Letter S for panic lock with FS908GE

Ordering example:SVA(A-G)-SOND-(SAA 6294-1/2)

KMS 2–101) lock mechanismsKMS 201–4001) lock mechanismsIndividual lock mechanisms, not suitable for master key systems

+S-SOND(KMS...)-T0903210

S-SOND(KMS...)-T0903207

There is no master key for KMS...- lock mechanisms(SAE) = Individual lock mechanism supplied with a security certificate

+S-SOND(SAE)-T0003212

S-SOND(SAE)-T0003209

(SA...) = Master key system (with master key) supplied with a security certificate. See also note below.2)

+S-SOND-(SA...)-T0914737

S-SOND-(SA...)-T0991023

SVA-T3 cylinder lock, Front IP65

Includes two keys

Key withdrawable in all positions KMS 1 lock mechanismIndividual lock mechanism, not suitable for master key systems

T0-.../E, .../I1, .../Z T3-.../E, .../I2, .../Z P1-.../E, .../I2, .../Z

Key withdrawal positions are programmed ex-works to match the switch

+SVA-T3050962

Key withdrawal positions can be programmed by the user

SVA-T3050974

1 off

KMS 2–101) lock mechanismsKMS 201–4001) lock mechanismsIndividual lock mechanisms, not suitable for master key systems

+SVA-SOND-KMS...-T3907739

SVA-SOND-KMS...-T3907747

Key can be withdrawn in positions as specified KMS 1 lock mechanismSwitches with FS 908 are suitable as main switches:T0-1-... to T0-4-.../I1, .../E T3-1-... to T3-5-.../I2T3-1-... to T3-6- .../EP1-.../I2, .../E

T0-.../E, .../I1, .../Z T3-.../E, .../I2, .../Z P1-.../E, .../I2, .../Z

Key withdrawal positions are programmed ex-works as ordered

+SVA(...)-T3907737

Key withdrawal positions are programmed ex-works as ordered

SVA(...)-T3907745

KMS 2–101) lock mechanismsKMS 201–4001) lock mechanismsIndividual lock mechanisms, not suitable for master key systems

+SVA(...)-SOND-KMS...-T3907734

SVA(...)-SOND-KMS...-T3907742

(SAE) = Individual lock mechanism supplied with a security certificate

+SVA(...)-SOND-SAE-T3907736

SVA(...)-SOND-SAE-T3907744

(SA...) = Master key system (with master key) supplied with a security certificate. Order must include a lock plan (FO276) showing the full configuration of the envisaged lock system. For subsequent part orders, simply state the item number within the lock plan, e.g. (X4711, item 7).2)

+SVA(...)-SOND-(SA...)-T3914735

SVA(...)-SOND-(SA...)-T3914736

Notes 1) KMS 1: can be supplied ex-stock; KMS 2 – 10, 201 – 400and master key systems: delivery time < 6 weeks from order receipt at the factory

2) For subsequent orders, the keys must be ordered separately

a Page 07/061

330 0 30

300

240225

210180

150

135120

90

6045

270

F

HG

J

KL

MN

PQ

R

A

BC

DE

315

07/058 07/059

Page 37: 07/000 T Rotary Switches, P Switch-Disconnectors · Moeller HPL0211-2001/2002 T Rotary Switches, P Switch-Disconnectors Overview of Functions Rotary Switches Switch-Disconnectors

Moeller HPL0211-2001/2002

T Rotary Switches, P Switch-DisconnectorsAccessories

Rota

ry S

witc

hes

Swit

ch-D

isco

nnec

tors

Rota

ry S

wit

ches

Swit

ch-D

isco

nnec

tors

Moeller HPL0211-2001/2002

T Rotary Switches, P Switch-DisconnectorsAccessories

For use with Locking facility Type suffix Price Locking facility Type PriceArticle no. See Price

ListArticle no. See Price

ListStd. pack Notes

When orderedwith basic unit

When ordered separately

SVC-T3 padlocking feature, Front IP65

In the depressed position, the locking slide is lockable with up to 3 padlocks

All positions are lockable T0-.../E, .../I1, .../Z T3-.../E, .../I2, .../Z P1-.../E, .../I2, .../Z

Lockable positions are programmed ex-works to match the switch

+SVC-T3050963

Lockablepositions can be programmed by the user

SVC-T3050975

1 off SVC-T3 can be fitted to T0, T3 and P1 switches. Switching is carried out using the thumb-grip,and interlocking by depressing an actuator which can be locked in position using up to 3 padlocks. In standard applications, all positions are lockable. With type reference SVC(...)-T3, only the specified positions or ranges are lockable. Where ranges are locked, switching is possible only within a locked range, unless the padlock is removed first.The lockable positions or ranges for SVC(...)-T3 and the locked position for DTV(...)-T3 are shown below. As with SVA(...)-T3, use the code letters to state your selection on the order:Example 1: SVC(A)-T3 = Only position A lockableExample 2: SVC(A, E)-T3 = Positions A and E lockableExample 3: SVC(A–J)-T3 = Range A to J lockableExample 4: DTV(G)-T3 = The release mechanism must be actuated to allow switching in this position.Example 5: SVC(S)-T3 = Main switches, for use as Emergency-Stop devices to IEC / EN 60 204-1; with red handle and yellow front plate as panic lock version, lockable in positions A and E; switching is still possible from E to A, but not from A to E.When retrofitting the SVA-T3, use the front plate of the switch. With letter S for panic lock, use FS908GE. Ordering example: P1-25/I2-RT+SVC(S)-T3

Master keys must always be ordered separately. Please send or submit the security certificate with repeat orders. For SA(...), the precise designation of the key must be stated e.g. SVS-SA(A6294-1/2)

Specified positions or ranges are lockableSwitches with FS908 may be used as main switches for

T0-1-... to T0-4-.../I1, .../ET3-1-... to T3-5-.../I2 T3-1-... to T3-6-.../E P1-.../I2, .../E

Lockable positions are programmed ex- works as ordered

+SVC(...)-T3907740

Lockable positions are programmed ex- works as ordered

SVC(...)-T3907748

1 off

DTV-T3 push-button interlock, Front IP65

Only after depressing the release button is it possible to switch from an unlocked position or range into a locked position or range, but not the reverse (protection against tampering).With a padlock in place when the release button is in the non-actuated position, it is not possible to switch into the locked positions.

T0-.../E, .../I1, .../Z T3-.../E, .../I2, .../Z P1-.../E, .../I2, .../Z Lockable using2 padlocks

Lockable positions are programmed ex-works to match the switch

+DTV-T3050961

– 1 off

Specified positions lockedRelease mechanism can be locked in the non-actuatedposition with 1–2 padlocks

Lockable positions are programmed ex- works as ordered

+DTV(...)-T3907733

– 1 off

Locking cams (2 cams per set)For user to select indexingposition in which key canbe withdrawn

S-T0 for all switching angles – VR-T0089082

1 off

For changing the locked positions/ranges SVA-T3, SVC-T3, for all switching anglesfor DTV-T3: order 2

x VR-T3– VR-T3

0509871 off

Keys

For KMS 1 individual lock mechanism S-T0, SVA-T3 – SVS-KMS1001871

1 off

For KMS 2 – 10 individual lock mechanismor KMS 201 – 400

S-T0, SVA-T3 – SVS-KM...914714

For master key systems andrecorded individual lock mechanisms: state lockplan no. and lock

S-T0, SVA-T3 – SVS-SA(...)901982

330 0 30

300

240225

210180

150

135120

90

6045

270

F

HG

J

KL

MN

PQ

R

A

BC

DE

315

07/060 07/061

Page 38: 07/000 T Rotary Switches, P Switch-Disconnectors · Moeller HPL0211-2001/2002 T Rotary Switches, P Switch-Disconnectors Overview of Functions Rotary Switches Switch-Disconnectors

Moeller HPL0211-2001/2002

T Rotary Switches, P Switch-DisconnectorsAccessories

Rota

ry S

witc

hes

Swit

ch-D

isco

nnec

tors

Rota

ry S

wit

ches

Swit

ch-D

isco

nnec

tors

Moeller HPL0211-2001/2002

T Rotary Switches, P Switch-DisconnectorsAccessories

For use with Type suffix Price Type PriceArticle no. See Price

ListArticle no. See Price

ListStd. pack

When orderedwith basic unit

When ordered separately

Main switch assembly kits

Padlocking feature, exclusively for main switches, to permit them to be used as Emergency-Stop devices1)

Admissible for T0 up to 4 contact units and for T3... up to 6 contact units

T0-.../E, .../Z, .../I1 T3-.../E, .../Z, .../I2 P1-.../E, .../Z, .../I2

+SVB-T0026450

SVB-T0057892

1 off For locking in the 0 (Off) position:For switches with the positions 0 – I at 90° switching angle, as front plate: FS908

T5(B)-.../E, .../Z, .../I4 P3-63/E, .../Z, .../I4 P3-100/E, .../Z, .../I5

+SVB-P3026364

SVB-P3052999

1 off

Padlocking feature, exclusively for main switches without Emergency-Stop functionBlack handle, black locking collarAdmissible for T0 up to 4 contact units and for T3... up to 6 contact units

T0-.../E, .../Z, .../I1 T3-.../E, .../Z, .../I2 P1-.../E, .../Z, .../I2

+SVB-SW-T0076917

SVB-SW-T0060265

1 off For locking in the Off position or in the On position if required.Lockable using up to 3 padlocks

Padlocks with KMS lock mechanism, Type 219/38 (KMS...): please enquire.

T5(B)-.../E, .../Z, .../I4 P3-63/E, .../Z, .../I4 P3-100/E, .../Z, .../I5

– SVB-SW-P3062491

1 off

Main switch assembly kits, with PE terminal and N terminal

Padlocking feature, exclusively for main switches, to permit them to be used as Emergency-Stop devices1)

Admissible for T0 up to 4 contact units and for T3... up to 6 contact units

T0-.../E, .../Z T3-.../E, .../Z

– V/EA/SVB-T0062638

1 off For conversion of:

• T.../E flush mounting switches (with front plate FS908) into T.../EA/SVB... flush mounting main switches

• T.../Z rear mounting switches (with front plate FS908) into T.../V/SVB interlocked rear mounting main switches

T5(B)-.../E, .../Z – V/EA/SVB-T5045065

Padlocking feature, exclusively for main switches without Emergency-Stop functionBlack handle, black locking collarAdmissible for T0 up to 4 contact units and for T3... up to 6 contact units

T0-.../E, .../Z T3-.../E, .../Z

– V/EA/SVB-SW-T0065011

T5(B)-.../E, .../Z – V/EA/SVB-SW-T5045064

Thumb-grips

Black T0-.../E, .../EZ, .../IVS, .../Z, .../I1 T3-.../E, .../EZ, .../IVS, .../Z, .../I2 P1-.../E, .../EZ, .../IVS, .../Z, .../I2

– KNB-T0038909

1 off

Red T0-.../E, .../IVS, .../Z, .../I1 T3-.../E, .../IVS, .../Z, .../I2 P1-.../E, .../IVS, .../Z, .../I2

+KNB-RT-T0003214

KNB-RT-T0043655

When ordered separately:Use red handle to IEC/EN 60 204 for Emergency-Stop switches only, and order corresponding yellow front plate FS908GE-T0

Black T5(B)-.../E, .../Z, .../I4 P3-63/E, .../Z, .../I4 P3-100/E, .../Z, .../I5

– KNB-P3041282

1 off

Red T5(B)-.../E, .../Z, .../I4 P3-63/E, .../Z, .../I4 P3-100/E, .../Z, .../I5

+KNB-RT-P3003215

KNB-RT-P3046028

When ordered separately:Use red handle to IEC/EN 60 204 for Emergency-Stop switches only, and order corresponding yellow front plate FS908GE-P3

Maintenance keysFor interlocked main switches T0-.../V, T3-.../V, P1-.../V – KNK-T0

0006501 off Special devices for electricians, to allow them to switch

interlocked main switches On and Off, when the panel door is open for maintenance purposes (to IEC/EN 60 204 Part 1, Clause 5.1.1.1)

T5(B)-.../V, P3-.../V – KNK-P3000649

1 off

Notes 1) To IEC/EN 60 204-1; with red rotary handle and yellow locking collar, lockable in 0 (Off) position

07/062 07/063

Page 39: 07/000 T Rotary Switches, P Switch-Disconnectors · Moeller HPL0211-2001/2002 T Rotary Switches, P Switch-Disconnectors Overview of Functions Rotary Switches Switch-Disconnectors

Moeller HPL0211-2001/2002

T Rotary Switches, P Switch-DisconnectorsAccessories

Rota

ry S

witc

hes

Swit

ch-D

isco

nnec

tors

Rota

ry S

wit

ches

Swit

ch-D

isco

nnec

tors

Moeller HPL0211-2001/2002

T Rotary Switches, P Switch-DisconnectorsAccessories

For use with Type suffix Price Type PriceArticle no. See Price

ListStd. pack Article no. See Price

ListStd. pack

When orderedwith basic unit

When ordered separately

Neutral poles

Early-make, late-break

Can be fitted to left and/or right of 3-pole P switch-disconnectors P1-.../E, .../EA, .../EZ – N-P1E000651

5 off The neutral contact is always early-make and late-break.

Switching capacity of N-P1... equivalent to P1-32... contacts

with P1-.../I2:optional N-P1Z or HI11-P1/P3Zcan only be fitted to left

P1-.../Z, .../V, .../I2, .../ST, .../IVS +N-P1Z000416

1 off N-P1Z000652

P3-.../E, .../EA... – N-P3E062432

The neutral contact is always early-make and late-break.

Switching capacity of N-P3... equivalent to P3-100... contacts

P3-.../Z, .../V, .../IVS P3-63/E, .../Z, .../I4, .../STP3-100/E, .../Z, .../I5, .../ST

+N-P3Z009036

1 off N-P3Z064805

Auxiliary contacts

1 make contact, 1 break contact

Can be fitted to left and/or right of 3-pole P switch-disconnectors P1-.../E, .../EA..., .../EZ P3-.../E, .../EA

+HI11-P1/P3E064100

1 off HI11-P1/P3E061813

5 off The make contact is always connected as a load-shedding contact, i.e. late-make, early-break.

With P1-.../I2:HI11-P1/P3Z or N-P1Z can be fitted to left only

P1-.../Z, .../V, .../I2, .../ST, .../IVS P3-63/Z, .../V, .../I4, .../ST, .../IVSP3-100/Z, .../V, .../I5, .../ST, .../IVS

+HI11-P1/P3Z064526

1 off HI11-P1/P3Z062031

5 off

Centre mounting accessories

For single-hole fittingMounting diameter 22.3 mm

With front plate T0-.../E, T3-.../E +EZ-T0001750

1 off EZ-T0081622

1 off Rapid snap-fitting in panel sides, plates and doors.Legend plates from the RMQ range of control circuit devices can be used.Without front plate

For engraved front platesT0-.../E, T3-.../E +EZ/OFS-T0

0017511 off EZ/OFS-T0

0018691 off

Mounting diameter 22.3 mm and 30.5 mm T0-.../E, T3-.../E, P1-.../E +EZ-P1026222

1 off EZ-P1091455

5 off Screw fixing enables one person to fit the equipment into panel sides, plates and doors.Legend plates from the RMQ range of control circuit devices can be used.

Service distribution board mounting accessoriesIncludes push-fit shaft T0-.../XZ +IVS-T0

0454721 off IVS-T0

0911141 off Use the front plate of the basic switch

For retrofitting T0-.../XZ basic switches as T0-.../IVS into service distribution boards

07/064 07/065

Page 40: 07/000 T Rotary Switches, P Switch-Disconnectors · Moeller HPL0211-2001/2002 T Rotary Switches, P Switch-Disconnectors Overview of Functions Rotary Switches Switch-Disconnectors

Moeller HPL0211-2001/2002

T Rotary Switches, P Switch-DisconnectorsAccessories

Rota

ry S

witc

hes

Swit

ch-D

isco

nnec

tors

Rota

ry S

wit

ches

Swit

ch-D

isco

nnec

tors

Moeller HPL0211-2001/2002

T Rotary Switches, P Switch-DisconnectorsAccessories

For use with Type suffix Price Type PriceArticle no. See Price

ListStd. pack Article no. See Price

ListStd. pack

When orderedwith basic unit

When ordered separately

Coupling drive

Includes push-fit shaft

For retrofitting T0(T3)-.../XZ basic switchesin the rear mounting form Spare parts for T0(T3)/(P1)-.../Z

– DE-T0093487

1 off

For conversion of T5 (B)-.../E flush mounting switchinto a rear mounting switchSpare parts for T5(B)/(P3)-.../Z

– DE-P3093972

3 off

Interlock sections

With PE and N conductor connection T0-.../E, .../EZ T3-.../E, .../EZ P1-.../E, .../EZ

+UV-T0038519

1 off UV-T0019925

1 off Fits on the reverse of flush mounting switches

T5(B)-.../E P3-.../E

+UV-P3030402

1 off UV-P3048289

1 off

For cover or door interlockWith PE and N conductor connection

T0-.../Z T3-.../Z P1-.../Z

+UV-T0038519

1 off UV-T0019925

1 off With interlocking function for rear mounting switches

T5(B)-.../Z P3-.../Z

+UV-P3030402

1 off UV-P3048289

1 off

Interlock extensions1) Up to four off, 25 mm each, can be plugged onto interlock section(An equal number of shaft extensions is required for this purpose)

UV-T0 +ZVV-T0024662

1 off ZVV-T0022298

10 off Notes relating to installation in enclosures

a Page 07/089UV-P3 +ZVV-P3

0243791 off ZVV-P3

02467110 off

Shaft extensionsUp to four off, 25 mm each,can be plugged onto switch shaft

T0-.../Z T3-.../Z P1-.../Z

+ZAV-T0023736

1 off ZAV-T0027044

10 off Notes relating to installation in enclosures

a Page 07/089

T5(B)-.../Z P3-.../Z

+ZAV-P3026623

1 off ZAV-P3029417

10 off

Notes 1) Use ZVV-T0 only with T0/T3-.../Z and P1-.../Z Use ZVV-P3 only with T5(B)-.../Z and P3-.../Z

07/066 07/067

Page 41: 07/000 T Rotary Switches, P Switch-Disconnectors · Moeller HPL0211-2001/2002 T Rotary Switches, P Switch-Disconnectors Overview of Functions Rotary Switches Switch-Disconnectors

Moeller HPL0211-2001/2002

T Rotary Switches, P Switch-DisconnectorsAccessories

Rota

ry S

witc

hes

Swit

ch-D

isco

nnec

tors

Rota

ry S

wit

ches

Swit

ch-D

isco

nnec

tors

Moeller HPL0211-2001/2002

T Rotary Switches, P Switch-DisconnectorsAccessories

For use with Type suffix Price Type PriceArticle no. See Price

ListArticle no. See Price

ListStd. pack

When orderedwith basic unit

When ordered separately

Sleeves/coversFor flush-mounting switches with up to 4 contact units T0-.../E

T3-.../E P1-.../E

– H3-T0093828

1 off Cable entriesQuantity:

2

x

o 20 mm+ 2

x

o 15 mmCross-section: 5

x 6 mm2 5

x 2.5 mm2

Cover for protection of terminalsFor up to 2 contact units

T5(B)-.../E, .../Z – H1-T5045062

1 off Can be used for input and/or output wiring

Extension of H1-T5 coverTo protect 3 to 8 contact units

H1-T5 – HZ-T5045063

10 off 1

x HZ-T5 required per contact unit

To cover terminals on3-pole switch-disconnectors

P1-.../E, .../EZ, .../Z, .../EA, .../V – H-P1017253

5 off Can be used for input and/or output wiring

P1-...N, ...HI11, ...N...HI11 – H-P14019626

5 off

To cover terminals on3-pole open switch-disconnectors with N neutral conductor and/or HI11 auxiliary contact modules fitted

P3-.../E, .../Z, .../EA, .../V P3-...N, ...HI11, ...N...HI11

– H-P3021999

5 off The shroud is designed for fitting onto both sides of the switch-disconnector. Parts which are not required can be broken off.

Cover assembly to protect the 6 terminals T6-160-6/... – H-T6-160200183

1 off

Cover assembly to protect the 6 terminals T8-3-8342/... – H-T8200184

1 off

07/068 07/069

Page 42: 07/000 T Rotary Switches, P Switch-Disconnectors · Moeller HPL0211-2001/2002 T Rotary Switches, P Switch-Disconnectors Overview of Functions Rotary Switches Switch-Disconnectors

Moeller HPL0211-2001/2002

T Rotary Switches, P Switch-DisconnectorsAccessories

Rota

ry S

witc

hes

Swit

ch-D

isco

nnec

tors

07/070

For use with Type PriceArticle no. See Price

ListStd. pack

Insulated enclosures, IP65Enclosures designed for metric cable glands to EN 50 262

1 – 2 contact units T0-.../XZ CI-K1-T0-2207435

1 off Cable sizes which may be pushed through the diaphragm

3 – 4 contact units T0-.../XZ CI-K1-T0-4207436 Type Main-/control current

1 – 2 contact units T3-.../XZ CI-K2-T3-2207437

Cl-K1-T0-...Cl-K2-T3-...

12 mm16 mm

–8 mm

3 – 4 contact units T3-.../XZ CI-K2-T3-4225325

5 contact units T3-.../Z CI-K2-T3-5207438

1 – 2 contact units T5B-.../E CI-K4-T5B-2207439

3 – 4 contact units T5B-.../Z CI-K4-T5B-4207440

1 – 2 contact units T5-.../Z CI-K5-T5-2207441

Converts T5-.../Z into T5-.../I5 and T5B-.../E into T5B.../I4:Order AW-T5-... extension terminals in addition

a Page 07/0713 – 4 contact units T5-.../Z CI-K5-T5-4

207442

Neutral terminals

For connection of 5th conductor T0-.../I1, Cl-K1-T0-...T3-.../I2, Cl-K2-T3-...P1-.../I2

K-CI-K1/2207451

20 off

T5B-.../I4, Cl-K4-T5B-...P3-.../I4

K-CI-K4206916

20 off

T5-.../I5, Cl-K5-T5-...P3-.../I5

K-CI-K5218488

1 off

Set of external fixing bracketsT5B-.../I4, T5-.../I5,P3-63/I4, P3-100/I5,

AB-CI-K4/5206914

1 off For fixing CI-K4 and CI-K5 directly to the wallOne set comprises 4 brackets

Metric diaphragm grommets

• IP65• With integral push-through diaphragm

External cable diametermm

Cable entry Hole diametermm

H03VV-F 3

x 0.75 mm², NYM 5

x 1.5/5

x 2.5 mm²KT-M20207602

100 off 1 – 13 M20 20.5

H03VV-F 3

x 0.75 mm², NYM 4

x 10 mm²KT-M25207603

1 – 18 M25 25.5

H03VV-F 3

x 0.75 mm², NYM 4

x 16/5

x 10 mm²KT-M32207604

1 – 24 M32 32.5

Metric cable glands to EN 50 262

• With lock nut and integral cable clamp• IP68 up to 5 bar, halogen free

H05VV-F 4

x 2.5/3

x 4 mm², NYM 5

x 1.5/5

x 2,5 mm²V-M20206910

20 off 6 – 13 M20 20.5

H05VV-F 5

x 2.5/5

x 4 mm², NYM 5

x 2.5/5

x 6 mm²V-M25206911

20 off 9 – 17 M25 25.5

NYM 5

x 10 mm² V-M32206912

10 off 13 – 21 M32 32.5

NYM 5

x 16 mm² V-M32G226156

10 off 18 – 25 M32 32.5

NYM 4

x 35/5

x 25 mm² V-M50206913

5 off 18 – 35 M50 50.5

Page 43: 07/000 T Rotary Switches, P Switch-Disconnectors · Moeller HPL0211-2001/2002 T Rotary Switches, P Switch-Disconnectors Overview of Functions Rotary Switches Switch-Disconnectors

Rota

ry S

wit

ches

Swit

ch-D

isco

nnec

tors

07/071Moeller HPL0211-2001/2002

T Rotary Switches, P Switch-DisconnectorsAccessories

For use with Type PriceArticle no. See Price

ListStd. pack

Set of extension terminalsFor cable connection in the enclosure

For the lowest contact unit T5B-.../I4 T5-.../I5

AW-T5-1/2032601

1 off Included with T5B-.../I4 and T5-.../I5 as standardFit T5(B) with extension terminals to install it as T5(B)-.../E in an insulated enclosure.

For the second contact unit from the bottom T5-.../I5 AW-T5-3/4032602

1 off

Indicator lights, conical, BA9sFor fitting in M20/M25 pre-mouldings in the enclosure baseFor filament bulbs and neon bulbs up to 2.4 W

a Page 02/040

Colour: red P1-.../I2, P3-.../I..., T...-.../I...

L-R208689

5 off

Colour: white L-W208692

Colour: green L-G208690

Colour: yellow L-Y208691

Set of adapter ringsTo allow PG cable glands to be used in metric cable entries

M25-PG16218923

1 set 1 set = 50 off

M32-PG21218924

1 set = 25 off

M40-PG29218925

1 set = 10 off

M50-PG36218926

1 set = 10 off

Page 44: 07/000 T Rotary Switches, P Switch-Disconnectors · Moeller HPL0211-2001/2002 T Rotary Switches, P Switch-Disconnectors Overview of Functions Rotary Switches Switch-Disconnectors

Moeller HPL0211-2001/2002

TM Mini Rotary SwitchesSystem Overview

Rota

ry S

witc

hes

Swit

ch-D

isco

nnec

tors

07/072

TM On-Off switches

TM control switches

1

2

5

3

4

4

4

66

6

7

8

8

8

8

9

8

9

10

8

AUTO

HAND

O

2

11

3

4

5

66

6 4

4

9

9

10

1

Page 45: 07/000 T Rotary Switches, P Switch-Disconnectors · Moeller HPL0211-2001/2002 T Rotary Switches, P Switch-Disconnectors Overview of Functions Rotary Switches Switch-Disconnectors

Rota

ry S

wit

ches

Swit

ch-D

isco

nnec

tors

07/073Moeller HPL0211-2001/2002

TM Mini Rotary SwitchesSystem Overview

Flush mounting (.../E) 1Front IP65Fitting from rear in panel sides, platesor doorsTerminal:Pozidriv screwFinger-proof

a Page 07/074

Flush mountingcontrol circuit isolators (.../E/SVB)

1

Front IP65To IEC/EN 60 947-5Lockable in 0 (Off) position using two padlocks, 4 mm ∅ or 1 padlock, 6 mm ∅Can be used at up to 250 V AC per contactUp to 6 contacts admissible

a Page 07/074

Product attributes

Contact chamber• Rated uninterrupted current 10 A• Gold-plated contacts for safe switching

of extra low voltages and currentseven in corrosive atmospheres

• Positively opening contacts• 1 – 2 contacts per contact chamber,

up to 16 contacts per switch• Switching of differing potentials• Control circuit reliability

Centre mounting (.../EZ) 2Front IP65Mounting in a standard 16.2 mm aperture, or in 22.3 mm to IEC/EN 60 947-5-1 following removal of supplied adapterM22-ST... legend plate mounts from the RMQ control circuit range can be used for marking(see Page 02/027)

a Page 07/074

Key operation for centre mounting 3, 42 keys are suppliedOption for key withdrawal at 90° with KABA micro cylinder lockOption for key withdrawal at 60° withRONIS cylinder lockAlways state the position in which the key is to be withdrawable

a Page 07/083

Circuit diagrams (examples)

Switch position 1:Contact 1 – 2 open,Contact 3 – 4 closed.

Switching from 1 to 2:Contact 1 – 2 early-make,Contact 3 – 4 late-break.

Switching from 2 to 3:Contact 1 – 2 opens briefly.

Switching from 3 to 4:Contact 1 – 2 remains closed.

1

2

3

4Terminal marking

Link

0

1

2

Contact open

Contact closed

Switch position

1

2

3

4

0

1

2

3

4

Centre mounting switches, standard 5, 6Black thumb-grip and silver-coloured front plate

a Page 07/074

Control circuit isolators 7, 8Red rotary handle and yellow locking collarBlack rotary handle and black locking collarLockable in the 0 (Off) position

a Page 07/074

Flush mounting switches, standard 9, 10Black thumb-grip and silver-coloured front plate

a Page 07/074

Standard switches for distribution board mounting (.../IVS)

11

Mounting in service distribution boardsMounting width: 2 space units(45 mm mounting depth)Up to 2 contact units

a Page 07/074

Switch position• Reliable switching due to indexing

mechanism

• Switching angles 30°, 45°, 60°, 90°• Automatic return with up to

6 contacts• Complete rotation• Switching angle of 360°

allows complete rotation in both directions

Page 46: 07/000 T Rotary Switches, P Switch-Disconnectors · Moeller HPL0211-2001/2002 T Rotary Switches, P Switch-Disconnectors Overview of Functions Rotary Switches Switch-Disconnectors

Moeller HPL0211-2001/2002

TM Mini Rotary SwitchesControl Circuit Isolators, On-Off Switches

Rota

ry S

witc

hes

Swit

ch-D

isco

nnec

tors

07/074

Circuit diagram Front plate no.

No. of poles

Flush mountingFront IP65

Centre mountingFront IP65

Service distribution board mountingFront IP30

Type Price Type Price Type PriceArticle no. See Price

ListArticle no. See Price

ListArticle no. See Price

List

Control circuit isolators, 90°

With padlocking facility, lockable in the Off positionUp to 250 V AC per contact

1 TM-1-8290/E/SVB045477

– –

TM-1-8290/E/SVB-SW215351

– –

2 TM-1-8291/E/SVB045478

– –

TM-1-8291/E/SVB-SW215352

– –

3 TM-2-8292/E/SVB045484

– –

TM-2-8292/E/SVB-SW210955

– –

3+N TM-2-8293/E/SVB045485

– –

TM-2-8293/E/SVB-SW215353

– –

6 TM-3-8326/E/SVB045498

– –

TM-3-8326/E/SVB-SW215354

– –

On-Off switches, 90°1 TM-1-8290/E

070131TM-1-8290/EZ000693

TM-1-8290/IVS225334

2 TM-1-8291/E072504

TM-1-8291/EZ015073

TM-1-8291/IVS225335

3 TM-2-8292/E074877

TM-2-8292/EZ015096

TM-2-8292/IVS225336

3+N TM-2-8293/E077250

TM-2-8293/EZ045486

TM-2-8293/IVS225337

6 TM-3-8326/E079623

TM-3-8326/EZ045499

Standard pack: 1 off

01

2

1

01

2

1

4

3

01

2

1 3

4

5

6

01

2

1 3

4

5

6

7

8

2

1 3

4

5

6

7

8

9

10

11

1201

2

1

01

1

0

F 056

2

1 3

4

01

1

0

F 056

2

1 3

4

5

6

01

1

0

F 056

2

1 3

4

5

6

7

8

01

1

0

F 056

2

1 3

4

5

6

7

8

9

10

11

1201

1

0

F 056

Page 47: 07/000 T Rotary Switches, P Switch-Disconnectors · Moeller HPL0211-2001/2002 T Rotary Switches, P Switch-Disconnectors Overview of Functions Rotary Switches Switch-Disconnectors

Rota

ry S

wit

ches

Swit

ch-D

isco

nnec

tors

07/075Moeller HPL0211-2001/2002

TM Mini Rotary SwitchesControl Switches: Changeover Switches

Circuit diagram Front plate no.

No. of poles

Flush mountingFront IP65

Centre mountingFront IP65

Service distribution board mountingFront IP30

Type Price Type Price Type PriceArticle no. See Price

ListArticle no. See Price

ListArticle no. See Price

List

Changeover switches without 0 (Off) position, 60°1 TM-1-8220/E

081996TM-1-8220/EZ000692

TM-1-8220/IVS225338

2 TM-2-8221/E084369

TM-2-8221/EZ015197

TM-2-8221/IVS225339

3 TM-3-8222/E086742

TM-3-8222/EZ045493

4 TM-4-8223/E089115

TM-4-8223/EZ046119

5 TM-5-8369/E091488

TM-5-8369/EZ046126

6 TM-6-8370/E093861

TM-6-8370/EZ046130

Changeover switches with 0 (Off) position, 60°1 TM-1-8210/E

096234TM-1-8210/EZ015137

TM-1-8210/IVS225340

2 TM-2-8211/E098607

TM-2-8211/EZ015166

TM-2-8211/IVS225341

3 TM-3-8212/E010807

TM-3-8212/EZ045491

4 TM-4-8213/E013180

TM-4-8213/EZ045847

Standard pack: 1 off

2

1 3

4

12 F 072

1 2

2

1 3

4

5

6

7

8

12 F 072

1 2

2

1 3

4

5

6

7

8

9

10

11

12

12 F 072

1 2

2

1 3

4

5

6

7

8

9

10

11

12

13 15

1614

12 F 072

1 2

2

1 3

4

5

6

7

8

9

10

11

12

13 15

1614

17 19

2018

12 F 072

1 2

12

2

1 3

4

5

6

7

8

9

10

11

12

13 15

1614

17 19

2018

21

22 24

23

F 072

1 2

2

1 3

4

201

F 071

1 20

2

2

1 3

4

5

6

7

8

01

F 071

1 20

2

1 3

4

5

6

7

8

9

10

11

12

102 F 249

102

2

1 3

4

5

6

7

8

9

10

11

12

13 15

1614

102 F 249

102

Page 48: 07/000 T Rotary Switches, P Switch-Disconnectors · Moeller HPL0211-2001/2002 T Rotary Switches, P Switch-Disconnectors Overview of Functions Rotary Switches Switch-Disconnectors

Moeller HPL0211-2001/2002

TM Mini Rotary SwitchesControl Switches: Changeover Switches, Hand/Auto Switches

Rota

ry S

witc

hes

Swit

ch-D

isco

nnec

tors

07/076

Circuit diagram Front plate no.

No. of poles

Flush mountingFront IP65

Centre mountingFront IP65

Service distribution board mountingFront IP30

Type Price Type Price Type PriceArticle no. See Price

ListArticle no. See Price

ListArticle no. See Price

ListChangeover switches with 0 (Off) position, 90°

1 TM-1-8218/E015553

TM-1-8218/EZ045476

2 TM-2-8219/E017926

TM-2-8219/EZ045482

3 TM-3-8299/E020299

TM-3-8299/EZ045497

3+N TM-4-8294/E022672

TM-4-8294/EZ046121

Hand/Auto switches, 60°1 – TM-1-8220 F288/EZ

016925–

1 TM-1-15431/E025045

TM-1-15431/EZ000691

TM-1-15431/IVS225342

2 TM-2-15432/E027418

TM-2-15432/EZ016878

TM-2-15432/IVS225343

3 TM-3-15433/E029791

TM-3-15433/EZ045490

Changeover switches with spring-return from both directions, 30°

1 TM-1-8214/E032164

TM-1-8214/EZ016673

2 TM-2-8215/E034537

TM-2-8215/EZ045481

3 TM-3-8216/E036910

TM-3-8216/EZ045492

Standard pack: 1 off

2

1 3

4

201

F 057

0

1 2

2

1 3

4

5

6

7

8

201

F 057

0

1 2

2

1 3

4

5

6

7

8

9

10

11

12

201

F 057

0

1 2

2

1 3

4

5

6

7

8

9

10

11

12

13 15

1614

201

F 057

0

1 2

2

1 3

4

AUTOHAND

F 288

HAND AUTOM

2

1 3

4

HAND

AUTO0 F 085

0HAND AUTO

0AUTO

HAND

2

1 3

4

5

6

7

8

F 085

0HAND AUTO

AUTO

HAND0

2

1 3

4

5

6

7

8

9

10

11

12

F 085

0HAND AUTO

2

1 3

4

102 F 025

01 2

2

1 3

4

5

6

7

8

102 F 025

01 2

2

1 3

4

5

6

7

8

9

10

11

12

102 F 025

01 2

Page 49: 07/000 T Rotary Switches, P Switch-Disconnectors · Moeller HPL0211-2001/2002 T Rotary Switches, P Switch-Disconnectors Overview of Functions Rotary Switches Switch-Disconnectors

Rota

ry S

wit

ches

Swit

ch-D

isco

nnec

tors

07/077Moeller HPL0211-2001/2002

TM Mini Rotary SwitchesControl Switches: Step Switches

Circuit diagram Front plate no.

No. of poles

Flush mountingFront IP65

Centre mountingFront IP65

Service distribution board mountingFront IP30

Type Price Type Price Type PriceArticle no. See Price

ListArticle no. See Price

ListArticle no. See Price

List

Step switches without 0 (Off) position, 60°3 steps

1 TM-2-8230/E039283

TM-2-8230/EZ000701

TM-2-8230/IVS225344

3 TM-5-8270/E041656

TM-5-8270/EZ046124

4 steps1 TM-2-8231/E

044029TM-2-8231/EZ000700

TM-2-8231/IVS225345

3 TM-6-8271/E046402

TM-6-8271/EZ046128

Standard pack: 1 off

2

1 3

4

5

6

321

F 076

2

1

3

2

1 3

4

5

6

7

8

9

10

11

12

13 15

1614

17

18

321

F 076

2

1

3

2

1 3

4

5

6

7

8

1234

F 077

2

1

3

4

2

1 3

4

5

6

7

8

9

10

11

12

13 15

1614

17 19

2018

21

22 24

23

1234

F 077

2

1

3

4

Page 50: 07/000 T Rotary Switches, P Switch-Disconnectors · Moeller HPL0211-2001/2002 T Rotary Switches, P Switch-Disconnectors Overview of Functions Rotary Switches Switch-Disconnectors

Moeller HPL0211-2001/2002

TM Mini Rotary SwitchesControl Switches: Step Switches

Rota

ry S

witc

hes

Swit

ch-D

isco

nnec

tors

07/078

Circuit diagram Front plate no. No. of poles

Flush mountingFront IP65

Centre mountingFront IP65

Type Price Type PriceArticle no. See Price

ListArticle no. See Price

List

Step switches without 0 (Off) position 5 steps, 60°

1 TM-3-8232/E039298

TM-3-8232/EZ015592

2 TM-5-8252/E041671

TM-5-8252/EZ046123

6 steps, 60°

Without complete rotation1 TM-3-8233/E

053521TM-3-8233/EZ015630

2 TM-6-8253/E055894

TM-6-8253/EZ046127

10 steps, 30°1 TM-5-8237/E

069150TM-5-8237/EZ015661

Standard pack: 1 off

321

45

2

1 3

4

5

6

7

8

9

10

F 078

2

1

3

4

5

321

45

2

1 3

4

5

6

7

8

9

10

11

12

13 15

1614

17 19

2018

F 078

2

1

3

4

5

2

1 3

4

5

6

7

8

9

10

11

12

321

456

21

34

56

F 079

2

1 3

4

5

6

7

8

9

10

11

12

13 15

1614

17 19

2018

21

22 24

23

321

456

21

34

56

F 079

321

45678 9

10

2

1 3

4

5

6

7

8

9

10

11

12

13 15

1614

17 19

2018

F 011

12

3 4 567

8910

Page 51: 07/000 T Rotary Switches, P Switch-Disconnectors · Moeller HPL0211-2001/2002 T Rotary Switches, P Switch-Disconnectors Overview of Functions Rotary Switches Switch-Disconnectors

Rota

ry S

wit

ches

Swit

ch-D

isco

nnec

tors

07/079Moeller HPL0211-2001/2002

TM Mini Rotary SwitchesControl Switches: Step Switches

Circuit diagram Front plate no. No. of poles

Flush mountingFront IP65

Centre mountingFront IP65

Type Price Type PriceArticle no. See Price

ListArticle no. See Price

List

Step switches with additional 0 (Off) position2 steps, 60°

1 TM-1-8240/E058267

TM-1-8240/EZ015226

2 TM-2-8260/E060640

TM-2-8260/EZ045483

3 TM-3-8280/E063013

TM-3-8280/EZ045496

3 steps, 45°1 TM-2-8241/E

065386TM-2-8241/EZ015256

2 TM-3-8261/E067759

TM-3-8261/EZ000698

3 TM-5-8281/E070132

TM-5-8281/EZ046125

4 steps, 30°1 TM-2-8242/E

072505TM-2-8242/EZ015506

2 TM-4-8262/E074878

TM-4-8262/EZ046120

3 TM-6-8282/E077251

TM-6-8282/EZ046129

Standard pack: 1 off

2

1 3

4

210

F 075

1

0

2

2

1 3

4

5

6

7

8

210

F 075

1

0

2

2

1 3

4

5

6

7

8

9

10

11

12

210

F 075

1

0

2

2

1 3

4

5

6

3210 F 109

0

1 2 3

2

1 3

4

5

6

7

8

9

10

11

12

3210 F 109

0

1 2 3

2

1 3

4

5

6

7

8

9

10

11

12

13 15

1614

17

18

3210 F 109

0

1 2 3

2

1 3

4

5

6

7

8

1234

0 F 002

01

2 3 4

2

1 3

4

5

6

7

8

9

10

11

12

13 15

1614

1234

0 F 002

01

2 3 4

2

1 3

4

5

6

7

8

9

10

11

12

13 15

1614

17 19

2018

21

22 24

23

1234

0 F 002

01

2 3 4

Page 52: 07/000 T Rotary Switches, P Switch-Disconnectors · Moeller HPL0211-2001/2002 T Rotary Switches, P Switch-Disconnectors Overview of Functions Rotary Switches Switch-Disconnectors

Moeller HPL0211-2001/2002

TM Mini Rotary SwitchesControl Switches: Step Switches, Group Switches

Rota

ry S

witc

hes

Swit

ch-D

isco

nnec

tors

07/080

Circuit diagram Front plate no. No. of poles

Flush mountingFront IP65

Centre mountingFront IP65

Type Price Type PriceArticle no. See Price

ListArticle no. See Price

List

Step switches with additional 0 (Off) position, 30°5 steps

1 TM-3-8243/E079624

TM-3-8243/EZ015537

6 steps1 TM-3-8244/E

081997TM-3-8244/EZ045495

9 steps1 TM-5-8247/E

009741TM-5-8247/EZ015565

Group switches2 groups, 60°

1 TM-1-8310/E084370

TM-1-8310/EZ045479

3 groups, 30°1 TM-2-8311/E

086743TM-2-8311/EZ045487

Standard pack: 1 off

2

1 3

4

5

6

7

8

9

10

321

45

0 F 003

12 3 4

50

2

1 3

4

5

6

7

8

9

10

11

12

321

45

0

6

F 004

12 3 4

560

2

1 3

4

5

6

7

8

9

10

11

12

13 15

1614

17

18

210

3456789

F 007

01

2 3 4567

89

2

1 3

4

210

F 075

1

0

2

2

1 3

4

5

6

210

3F 001

12 3

0

Page 53: 07/000 T Rotary Switches, P Switch-Disconnectors · Moeller HPL0211-2001/2002 T Rotary Switches, P Switch-Disconnectors Overview of Functions Rotary Switches Switch-Disconnectors

Rota

ry S

wit

ches

Swit

ch-D

isco

nnec

tors

07/081Moeller HPL0211-2001/2002

TM Mini Rotary SwitchesControl Switches: On/Off Switches, Spring-Return

Circuit diagram Front plate no. No. of poles

Flush mountingFront IP65

Centre mountingFront IP65

Type Price Type PriceArticle no. See Price

ListArticle no. See Price

List

On/Off switches with spring-return, 30°Off switches, spring-return

1 TM-1-8174/E089116

TM-1-8174/EZ016646

On switches, spring-return1 TM-1-8175/E

091489TM-1-8175/EZ015690

On-Off switches, spring-return1 TM-1-8176/E

093862TM-1-8176/EZ016714

2 TM-2-8183/E096235

TM-2-8183/EZ045480

On-Off spring-return switches, 90°/30°With spring-return from START to 1

1 TM-1-8178/E098608

TM-1-8178/EZ016786

Standard pack: 1 off

2

1

STOPF 022

STOP

2

1

START F 023

START

2

1 3

4

START

STOP F 024

STOP START

2

1 3

4

5

6

7

8

START

STOP F 024

STOP START

2

1 3

4

START

0

1

F 119

START

Page 54: 07/000 T Rotary Switches, P Switch-Disconnectors · Moeller HPL0211-2001/2002 T Rotary Switches, P Switch-Disconnectors Overview of Functions Rotary Switches Switch-Disconnectors

Moeller HPL0211-2001/2002

TM Mini Rotary SwitchesControl Switches: Reversing Switches, Coding Switches

Rota

ry S

witc

hes

Swit

ch-D

isco

nnec

tors

07/082

Circuit diagram Front plate no. No. of poles

Flush mountingFront IP65

Centre mountingFront IP65

Type Price Type PriceArticle no. See Price

ListArticle no. See Price

List

Reversing switchesWith spring-return from Start to 1 or 2, 60°/30°

1 TM-2-8177/E010808

TM-2-8177/EZ016838

Reversing switches, 60°2 TM-2-8400/E

013181TM-2-8400/EZ045488

3 TM-3-8401/E015554

TM-3-8401/EZ045500

Reversing switches with spring-return to 0, 30°3 TM-3-8228/E

017927TM-3-8228/EZ045494

Coding switches, BCD Code 0 – 9, 30°

1 TM-2-8550/E020300

TM-2-8550/EZ000699

Complementary BCD code 0 – 9, 30°1 TM-2-8551/E

022673TM-2-8551/EZ045489

BCD code 0 – 9 + complement, 30°1 TM-4-8552/E

025046TM-4-8552/EZ046122

Standard pack: 1 off

1

20

2

1 3

4

5

6

7

8

START

START

0 21

F 121

START START

2

1 3

4

5

6

7

8

201 F 071

1 20

2

1 3

4

5

6

7

8

9

10

201 F 071

1 20

2

1 3

4

5

6

7

8

9

10

102

F 025

01 2

2

1 3

4

5

6

7

8

210

3456789

F 007

01

2 3 4567

89

2

1 3

4

5

6

7

8

210

3456789

F 007

01

2 3 4567

89

2

1 3

4

5

6

7

8

9

10

11

12

13 15

1614

210

3456789

F 007

01

2 3 4567

89

Page 55: 07/000 T Rotary Switches, P Switch-Disconnectors · Moeller HPL0211-2001/2002 T Rotary Switches, P Switch-Disconnectors Overview of Functions Rotary Switches Switch-Disconnectors

Rota

ry S

wit

ches

Swit

ch-D

isco

nnec

tors

07/083Moeller HPL0211-2001/2002

TM Mini Rotary SwitchesAccessories

Type PriceArticle no. See Price

List

Key operation1)

Includes two keysKABA lock for 90° switching angle1)

Degree of protection IP65The key can be withdrawn only in specified positions, see diagrams below. However, the KABA lock mechanism for 90° can also be used for other switching angles provided the positions for key withdrawal correspond with those specified for the Type of switch. Example: +EZ/S-B can be used on a step switch having a switching angle of 30°, provided the key is to be with-drawn only in the Off position at 270°.The key is not withdrawable in positions which exceed the total switching angle of the switch.

Options for key withdrawal

For example of position marking see

a Page 07/111

Key withdrawable at: 0° +EZ/S-A045458

270° +EZ/S-B045459

270 + 0° +EZ/S-F045463

0 + 90° +EZ/S-E045462

270 + 0 + 90° +EZ/S-R045471

270 + 0 + 90 + 180° +EZ/S-G045464

RONIS lock for 60° switching angle1)

Degree of protection IP55Key withdrawable at: 0 + 180° +EZ/S-C

045460270 + 90° +EZ/S-D

045461300 + 0 + 60 + 120 + 180 + 240° +EZ/S-H

045465270 + 330 + 30 + 90 + 150 + 210° +EZ/S-J

0454660 + 60 + 180 + 240° +EZ/S-M

045467270 + 330 + 90 + 150° +EZ/S-N

045468300 + 0 + 120 + 180° +EZ/S-P

045469270 + 30 + 90 + 210° +EZ/S-Q

045470

Standard pack: 1 off 1) For mounting forms E and EZ

A B F E R G

C D H J M N P Q

3300

30

300

270

240 225

210180

150

135 120

90

60315 45

Page 56: 07/000 T Rotary Switches, P Switch-Disconnectors · Moeller HPL0211-2001/2002 T Rotary Switches, P Switch-Disconnectors Overview of Functions Rotary Switches Switch-Disconnectors

Moeller HPL0211-2001/2002

T Rotary SwitchesT0 Non-Standard Switches

Rota

ry S

witc

hes

Swit

ch-D

isco

nnec

tors

07/084

Type Price Type Price PriceSee Price List

See Price List

See Price List

Std. pack

T0 rotary switches T0-1-SOND.../E T0-5-SOND.../E 1 off T0-1-SOND.../EA/SVB T0-5-SOND.../EZ T0-1-SOND.../EA/SVB-SW T0-5-SOND.../EZ/OFS T0-1-SOND.../EZ T0-5-SOND.../IVS T0-1-SOND.../EZ/OFS T0-5-SOND.../XZ T0-1-SOND.../I1 T0-5-SOND.../Z T0-1-SOND.../I1/SVB T0-1-SOND.../I1/SVB-SW T0-6-SOND.../E T0-1-SOND.../IVS T0-6-SOND.../EZ T0-1-SOND.../V/SVB T0-6-SOND.../EZ/OFS T0-1-SOND.../V/SVB-SW T0-6-SOND.../IVS T0-1-SOND.../XZ T0-6-SOND.../XZ T0-1-SOND.../Z T0-6-SOND.../Z

T0-2-SOND.../E T0-7-SOND.../E T0-2-SOND.../EA/SVB T0-7-SOND.../EZ T0-2-SOND.../EA/SVB-SW T0-7-SOND.../EZ/OFS T0-2-SOND.../EZ T0-7-SOND.../IVS T0-2-SOND.../EZ/OFS T0-7-SOND.../XZ T0-2-SOND.../I1 T0-7-SOND.../Z T0-2-SOND.../I1/SVB T0-2-SOND.../I1/SVB-SW T0-8-SOND.../E T0-2-SOND.../IVS T0-8-SOND.../EZ T0-2-SOND.../V/SVB T0-8-SOND.../EZ/OFS T0-2-SOND.../V/SVB-SW T0-8-SOND.../IVS T0-2-SOND.../XZ T0-8-SOND.../XZ T0-2-SOND.../Z T0-8-SOND.../Z

T0-3-SOND.../E T0-9-SOND.../E T0-3-SOND.../EA/SVB T0-9-SOND.../EZ T0-3-SOND.../EA/SVB-SW T0-9-SOND.../EZ/OFS T0-3-SOND.../EZ T0-9-SOND.../IVS T0-3-SOND.../EZ/OFS T0-9-SOND.../XZ T0-3-SOND.../I1 T0-9-SOND.../Z T0-3-SOND.../I1/SVB T0-3-SOND.../I1/SVB-SW T0-10-SOND.../E T0-3-SOND.../IVS T0-10-SOND.../EZ T0-3-SOND.../V/SVB T0-10-SOND.../EZ/OFS T0-3-SOND.../V/SVB-SW T0-10-SOND.../IVS T0-3-SOND.../XZ T0-10-SOND.../XZ T0-3-SOND.../Z T0-10-SOND.../Z

T0-4-SOND.../E T0-11-SOND.../E T0-4-SOND.../EA/SVB T0-11-SOND.../EZ T0-4-SOND.../EA/SVB-SW T0-11-SOND.../EZ/OFS T0-4-SOND.../EZ T0-11-SOND.../IVS T0-4-SOND.../EZ/OFS T0-11-SOND.../XZ T0-4-SOND.../I1 T0-11-SOND.../Z T0-4-SOND.../I1/SVB T0-4-SOND.../I1/SVB-SW T0-4-SOND.../IVS T0-4-SOND.../V/SVB T0-4-SOND.../V/SVB-SW T0-4-SOND.../XZ T0-4-SOND.../Z

Notes These Pages show T rotary switches with non-

standard contact sequences (-SOND...) which are priced accordingly (See Price List). Use the Initial Order form on

a Page 07/112 for ordering any T rotary switch combination.

For subsequent orders, state contact sequence number together with country identifer (eg 4711GB)

The contact numbers for non-standard contact sequences are: >200 <8000 or >9000 <15000 or >16000.

Page 57: 07/000 T Rotary Switches, P Switch-Disconnectors · Moeller HPL0211-2001/2002 T Rotary Switches, P Switch-Disconnectors Overview of Functions Rotary Switches Switch-Disconnectors

Rota

ry S

wit

ches

Swit

ch-D

isco

nnec

tors

07/085Moeller HPL0211-2001/2002

T Rotary SwitchesT3 Non-Standard Switches

Type Price Type PriceSee Price List

See Price List

Std. pack

T3 rotary switches T3-1-SOND.../E T3-5-SOND.../E 1 off T3-1-SOND.../EA/SVB T3-5-SOND.../EA/SVB T3-1-SOND.../EA/SVB-SW T3-5-SOND.../EA/SVB-SW T3-1-SOND.../EZ T3-5-SOND.../EZ T3-1-SOND.../EZ/OFS T3-5-SOND.../EZ/OFS T3-1-SOND.../I2 T3-5-SOND.../I2 T3-1-SOND.../I2/SVB T3-5-SOND.../I2/SVB T3-1-SOND.../I2/SVB-SW T3-5-SOND.../I2/SVB-SW T3-1-SOND.../V/SVB T3-5-SOND.../V/SVB T3-1-SOND.../V/SVB-SW T3-5-SOND.../V/SVB-SW T3-1-SOND.../XZ T3-5-SOND.../XZ T3-1-SOND.../Z T3-5-SOND.../Z

T3-2-SOND.../E T3-6-SOND.../E T3-2-SOND.../EA/SVB T3-6-SOND.../EA/SVB T3-2-SOND.../EA/SVB-SW T3-6-SOND.../EA/SVB-SW T3-2-SOND.../EZ T3-6-SOND.../EZ T3-2-SOND.../EZ/OFS T3-6-SOND.../EZ/OFS T3-2-SOND.../I2 T3-6-SOND.../V/SVB T3-2-SOND.../I2/SVB T3-6-SOND.../V/SVB-SW T3-2-SOND.../I2/SVB-SW T3-6-SOND.../XZ T3-2-SOND.../V/SVB T3-6-SOND.../Z T3-2-SOND.../V/SVB-SW T3-2-SOND.../XZ T3-7-SOND.../E T3-2-SOND.../Z T3-7-SOND.../EZ

T3-7-SOND.../EZ/OFS T3-3-SOND.../E T3-7-SOND.../XZ T3-3-SOND.../EA/SVB T3-7-SOND.../Z T3-3-SOND.../EA/SVB-SW T3-3-SOND.../EZ T3-8-SOND.../E T3-3-SOND.../EZ/OFS T3-8-SOND.../EZ T3-3-SOND.../I2 T3-8-SOND.../EZ/OFS T3-3-SOND.../I2/SVB T3-8-SOND.../XZ T3-3-SOND.../I2/SVB-SW T3-8-SOND.../Z T3-3-SOND.../V/SVB T3-3-SOND.../V/SVB-SW T3-9-SOND.../E T3-3-SOND.../XZ T3-9-SOND.../EZ T3-3-SOND.../Z T3-9-SOND.../EZ/OFS

T3-9-SOND.../XZ T3-4-SOND.../E T3-9-SOND.../Z T3-4-SOND.../EA/SVB T3-4-SOND.../EA/SVB-SW T3-10-SOND.../E T3-4-SOND.../EZ T3-10-SOND.../EZ T3-4-SOND.../EZ/OFS T3-10-SOND.../EZ/OFS T3-4-SOND.../I2 T3-10-SOND.../XZ T3-4-SOND.../I2/SVB T3-10-SOND.../Z T3-4-SOND.../I2/SVB-SW T3-4-SOND.../V/SVB T3-11-SOND.../E T3-4-SOND.../V/SVB-SW T3-11-SOND.../EZ T3-4-SOND.../XZ T3-11-SOND.../EZ/OFS T3-4-SOND.../Z T3-11-SOND.../XZ

T3-11-SOND.../Z

Page 58: 07/000 T Rotary Switches, P Switch-Disconnectors · Moeller HPL0211-2001/2002 T Rotary Switches, P Switch-Disconnectors Overview of Functions Rotary Switches Switch-Disconnectors

Moeller HPL0211-2001/2002

T Rotary SwitchesT5B Non-Standard Switches

Rota

ry S

witc

hes

Swit

ch-D

isco

nnec

tors

07/086

Type Price Type PriceSee Price List

See Price List

Std. pack

T5B rotary switches T5B-1-SOND.../E T5B-5-SOND.../E 1 off T5B-1-SOND.../EA/SVB T5B-5-SOND.../EA/SVB T5B-1-SOND.../EA/SVB-SW T5B-5-SOND.../EA/SVB-SW T5B-1-SOND.../I4 T5B-5-SOND.../V/SVB T5B-1-SOND.../I4/SVB T5B-5-SOND.../V/SVB-SW T5B-1-SOND.../I4/SVB-SW T5B-5-SOND.../X T5B-1-SOND.../V/SVB T5B-5-SOND.../Z T5B-1-SOND.../V/SVB-SW T5B-1-SOND.../X T5B-6-SOND.../E T5B-1-SOND.../Z T5B-6-SOND.../EA/SVB

T5B-6-SOND.../EA/SVB-SW T5B-2-SOND.../E T5B-6-SOND.../V/SVB T5B-2-SOND.../EA/SVB T5B-6-SOND.../V/SVB-SW T5B-2-SOND.../EA/SVB-SW T5B-6-SOND.../X T5B-2-SOND.../I4 T5B-6-SOND.../Z T5B-2-SOND.../I4/SVB T5B-2-SOND.../I4/SVB-SW T5B-7-SOND.../E T5B-2-SOND.../V/SVB T5B-7-SOND.../EA/SVB T5B-2-SOND.../V/SVB-SW T5B-7-SOND.../EA/SVB-SW T5B-2-SOND.../X T5B-7-SOND.../V/SVB T5B-2-SOND.../Z T5B-7-SOND.../V/SVB-SW

T5B-7-SOND.../X T5B-3-SOND.../E T5B-7-SOND.../Z T5B-3-SOND.../EA/SVB T5B-3-SOND.../EA/SVB-SW T5B-8-SOND.../E T5B-3-SOND.../I4 T5B-8-SOND.../EA/SVB T5B-3-SOND.../I4/SVB T5B-8-SOND.../EA/SVB-SW T5B-3-SOND.../I4/SVB-SW T5B-8-SOND.../V/SVB T5B-3-SOND.../V/SVB T5B-8-SOND.../V/SVB-SW T5B-3-SOND.../V/SVB-SW T5B-8-SOND.../X T5B-3-SOND.../X T5B-8-SOND.../Z T5B-3-SOND.../Z

T5B-9-SOND.../E T5B-4-SOND.../E T5B-9-SOND.../X T5B-4-SOND.../EA/SVB T5B-9-SOND.../Z T5B-4-SOND.../EA/SVB-SW T5B-4-SOND.../I4 T5B-10-SOND.../E T5B-4-SOND.../I4/SVB T5B-10-SOND.../X T5B-4-SOND.../I4/SVB-SW T5B-10-SOND.../Z T5B-4-SOND.../V/SVB T5B-4-SOND.../V/SVB-SW T5B-4-SOND.../X T5B-4-SOND.../Z

Notes These Pages show T rotary switches with non-standard contact sequences (-SOND...) which are priced accordingly (See Price List). Use the Initial Order form on

a Page 07/112 for ordering any T rotary switch combination.

For subsequent orders, state contact sequence number together with country identifer (eg 4711GB)

The contact numbers for non-standard contact sequences are: >200 <8000 or >9000 <15000 or >16000.

Page 59: 07/000 T Rotary Switches, P Switch-Disconnectors · Moeller HPL0211-2001/2002 T Rotary Switches, P Switch-Disconnectors Overview of Functions Rotary Switches Switch-Disconnectors

Rota

ry S

wit

ches

Swit

ch-D

isco

nnec

tors

07/087Moeller HPL0211-2001/2002

T Rotary SwitchesT5 Non-Standard Switches

Type Price Type PriceSee Price List

See Price List

Std. pack

T5 rotary switches T5-1-SOND.../E T5-5-SOND.../E 1 off T5-1-SOND.../EA/SVB T5-5-SOND.../EA/SVB T5-1-SOND.../EA/SVB-SW T5-5-SOND.../EA/SVB-SW T5-1-SOND.../I5 T5-5-SOND.../V/SVB T5-1-SOND.../I5/SVB T5-5-SOND.../V/SVB-SW T5-1-SOND.../I5/SVB-SW T5-5-SOND.../X T5-1-SOND.../V/SVB T5-5-SOND.../Z T5-1-SOND.../V/SVB-SW T5-1-SOND.../X T5-6-SOND.../E T5-1-SOND.../Z T5-6-SOND.../EA/SVB

T5-6-SOND.../EA/SVB-SW T5-2-SOND.../E T5-6-SOND.../V/SVB T5-2-SOND.../EA/SVB T5-6-SOND.../V/SVB-SW T5-2-SOND.../EA/SVB-SW T5-6-SOND.../X T5-2-SOND.../I5 T5-6-SOND.../Z T5-2-SOND.../I5/SVB T5-2-SOND.../I5/SVB-SW T5-7-SOND.../E T5-2-SOND.../V/SVB T5-7-SOND.../EA/SVB T5-2-SOND.../V/SVB-SW T5-7-SOND.../EA/SVB-SW T5-2-SOND.../X T5-7-SOND.../V/SVB T5-2-SOND.../Z T5-7-SOND.../V/SVB-SW

T5-7-SOND.../X T5-3-SOND.../E T5-7-SOND.../Z T5-3-SOND.../EA/SVB T5-3-SOND.../EA/SVB-SW T5-8-SOND.../E T5-3-SOND.../I5 T5-8-SOND.../EA/SVB T5-3-SOND.../I5/SVB T5-8-SOND.../EA/SVB-SW T5-1-SOND.../I5/SVB-SW T5-8-SOND.../V/SVB T5-3-SOND.../V/SVB T5-8-SOND.../V/SVB-SW T5-3-SOND.../V/SVB-SW T5-8-SOND.../X T5-3-SOND.../X T5-8-SOND.../Z T5-3-SOND.../Z

T5-9-SOND.../E T5-4-SOND.../E T5-9-SOND.../X T5-4-SOND.../EA/SVB T5-9-SOND.../Z T5-4-SOND.../EA/SVB-SW T5-4-SOND.../I5 T5-10-SOND.../E T5-4-SOND.../I5/SVB T5-10-SOND.../X T5-4-SOND.../I5/SVB-SW T5-10-SOND.../Z T5-4-SOND.../V/SVB T5-4-SOND.../V/SVB-SW T5-4-SOND.../X T5-4-SOND.../Z

Page 60: 07/000 T Rotary Switches, P Switch-Disconnectors · Moeller HPL0211-2001/2002 T Rotary Switches, P Switch-Disconnectors Overview of Functions Rotary Switches Switch-Disconnectors

Moeller HPL0211-2001/2002

T Rotary SwitchesTM Non-Standard Switches, Bulk Packaged Switches

Rota

ry S

witc

hes

Swit

ch-D

isco

nnec

tors

07/088

Type1) Price Type2) PriceSee Price List

See Price List

Std. pack

TM mini rotary switches

TM-1-SOND.../E TM-1-SOND-ERSTBESTELLUNG/E 1 off TM-1-SOND.../EZ TM-1-SOND-ERSTBESTELLUNG/EZTM-1-SOND.../IVS TM-1-SOND-ERSTBESTELLUNG/IVS TM-2-SOND.../E TM-2-SOND-ERSTBESTELLUNG/E TM-2-SOND.../EZ TM-2-SOND-ERSTBESTELLUNG/EZ TM-2-SOND.../IVS TM-2-SOND-ERSTBESTELLUNG/IVS TM-3-SOND.../E TM-3-SOND-ERSTBESTELLUNG/E TM-3-SOND.../EZ TM-3-SOND-ERSTBESTELLUNG/EZ TM-4-SOND.../E TM-4-SOND-ERSTBESTELLUNG/E TM-4-SOND.../EZ TM-4-SOND-ERSTBESTELLUNG/EZ TM-5-SOND.../E TM-5-SOND-ERSTBESTELLUNG/E TM-5-SOND.../EZ TM-5-SOND-ERSTBESTELLUNG/EZ TM-6-SOND.../E TM-6-SOND-ERSTBESTELLUNG/E TM-6-SOND.../EZ TM-6-SOND-ERSTBESTELLUNG/EZ TM-7-SOND.../E TM-7-SOND-ERSTBESTELLUNG/E TM-7-SOND.../EZ TM-7-SOND-ERSTBESTELLUNG/EZ TM-8-SOND.../E TM-8-SOND-ERSTBESTELLUNG/E TM-8-SOND.../EZ TM-8-SOND-ERSTBESTELLUNG/EZ

Notes 1) For subsequent orders, for which the design number is known.Form FO2 is not required for these.

2) For initial orders. Form FO2 has to be completed and submitted for these.

Type PriceArticle no. See Price

ListStd. pack

Bulk packaged switches

T0-2-1/EA/SVB-GVP50217168

50 off

P1-25/EA/SVB-GVP50217370

50 off

P1-32/EA/SVB-GVP50217169

50 off

P3-63/EA/SVB-GVP25218130

25 off

P3-100/EA/SVB-GVP25218132

25 off

Page 61: 07/000 T Rotary Switches, P Switch-Disconnectors · Moeller HPL0211-2001/2002 T Rotary Switches, P Switch-Disconnectors Overview of Functions Rotary Switches Switch-Disconnectors

Rota

ry S

wit

ches

Swit

ch-D

isco

nnec

tors

07/089Moeller HPL0211-2001/2002

T Rotary SwitchesFitting Rotary Switches with Coupling (T.../Z or T.../V/SVB) into Enclosures

Notes

CI-K... insulated enclosures are enclosures specifically designed for the installation of rotary switches, such as T0, T5B and T5 with up to 4 contact units = 8 contacts, T3 with up to 5 contact units = 10 contacts. They have a high degree of protection and up to 5 cable entries. If more than 5 cables or large cross-section cables are to be connected, then we recommend the use of insulated enclosures from the CI System.

1) Select the required switch and determine the cables to be connected.

2) Select an enclosure (

a HPL0214-2001) according to the minimum mounting depth of the switch. This depth dimension has to be less than or equal to the internal mounting depth of the enclosure. In addition, the quantity and size of the cable entries must be taken into account.

Use the tables below to determine whether, and if so how many, ZAV-... shaft extensions are required and, for .../SVB switches, the identical quantity of ZVV-... interlock extensions.

Example:Switch:T3-6-.../V/SVBMinimum mounting depth:T...-6/Z = 147 mmExtensions:No extension is required for an enclosure having a mounting depth of 150 mm. Two ZAV-T0 shaft extensions and two ZVV-T0 interlock extensions are required for an enclosure having a mounting depth of 200 mm.

T0-...mounting depths

T3-...mounting depths

T5(B)-...mounting depths

Dimensions in mmWith extension Without/ With ZAV-T0 Without/ With ZAV-T0 Without/ With ZAV-P3Number +1 +2 +3 +4 +1 +2 +3 +4 +1 +2 +3 +4Switch type From To To To To To From To To To To To From To To To To ToT...-1-.../Z(V/SVB) 86 102 127 152 177 202 89 105 130 155 180 205 92 107 132 157 182 207T...-2-.../Z(V/SVB) 96 112 137 162 187 212 101 116 141 166 191 216 109 124 149 174 199 224T...-3-.../Z(V/SVB) 105 121 146 171 196 221 112 128 153 178 203 228 125 140 165 190 215 240T...-4-.../Z(V/SVB) 115 131 156 181 206 231 124 139 164 189 214 239 142 157 182 207 232 257T...-5-.../Z(V/SVB) 124 140 165 190 215 240 135 151 176 201 226 251 158 173 198 223 248 273T...-6-.../Z(V/SVB) 134 150 175 200 225 250 147 162 187 212 237 262 175 190 215 240 265 290T...-7-.../Z(V/SVB) 143 159 184 209 234 259 158 174 199 224 249 274 191 206 231 256 281 306T...-8-.../Z(V/SVB) 153 169 194 219 244 269 170 185 210 235 260 285 208 223 248 273 298 323T...-9-.../Z(V/SVB) 162 178 203 228 253 278 181 197 222 247 272 297 224 239 264 289 314 339T...-10-.../Z(V/SVB) 172 188 213 238 263 288 193 208 233 258 283 308 241 256 281 306 331 356T...-11-.../Z(V/SVB) 181 197 222 247 272 279 204 220 245 270 295 320

Page 62: 07/000 T Rotary Switches, P Switch-Disconnectors · Moeller HPL0211-2001/2002 T Rotary Switches, P Switch-Disconnectors Overview of Functions Rotary Switches Switch-Disconnectors

Moeller HPL0211-2001/2002

T Rotary SwitchesTechnical Data

Rota

ry S

witc

hes

Swit

ch-D

isco

nnec

tors

07/090

T0-... T3-... T5B-... T5-... T6-...(T6-160-6)

T8-...

General technical dataStandards IEC/EN 60 947, IEC/EN 60 204, CSA, UL

Switch-disconnector to IEC/EN 60 947-3Load-break switch to IEC/EN 60 947-3Shipping classifications

a SK0200-1043Lifespan, mechanicalMax. operating frequency

OperationsOps./h

> 106

30005

x 105

30005

x 105

30005

x 105

3000> 105

50> 105

50 Climatic proofing Damp heat, constant, to IEC 60 068 Part 2-3

Damp heat, cyclical, to IEC 60 068 Part 2-30Ambient temperature Open Min./Max. °C −25/+50 −25/+50 −25/+50 −25/+50 −25/+50 −25/+50

Enclosed Min./Max. °C −25/+40 −25/+40 −25/+40 −25/+40 −25/+40 −25/+40Mounting position As requiredDimensions

a Page 07/096

a Page 07/101

a Page 07/103Weight

a Page 15/023Mechanical shock resistance (shock duration 20 ms) g > 15 > 15 4) > 15 > 15 > 15 –ContactsRated operational voltage

Ue V AC 690 690 690 690 690 690Rated impulse withstand voltage

Uimp V 6000 6000 6000 6000 6000 (8000)2) 8000Overvoltage category/pollution degree III/3 III/3 III/3 III/3 III/3 III/3Rated uninterrupted current

Iu with max. cable connected A 20 32 63 1005) 125 (160)2) 3156)

Load-carrying capacity in intermittent operation, Class 12, AB 60/40/25

% DF 1.3/1.6/2

x

Ie

Short-circuit rating maximum fuse A gG/gL 20 25 80 100 200 (160)2) 315

Rated short-time withstand current (1 s current)

Icw Arms 320 650 1300 1850 2000 (3000)2) 4200Safe isolation to IEC 536 between the contacts V AC 440 440 440 440 – –

Protection against direct contact Finger and back-of-hand proofto IEC 536

– –

Switching angles 90°/60°/45°/30° 90°/60° 60° (90°)3

Contact units Max. 11 11 10 10 3 3Double-break contacts Max. 22 22 20 20 6 6Current heat loss per contact at

Ie W 0.6 1.1 4.5 7.5 11 11Terminal capacitySolid or stranded1) mm2 1

x

(1 – 2.5)1

x

(1 – 6)1

x

(2.5 – 35)1

x

(2.5 – 35)1

x 70 (95)2) 150

mm2 2

x

(1 – 2.5)2

x

( 1 – 6)2

x

(2.5 – 16)2

x

(2.5 – 16)2

x 25 –

Flexible with ferrule1)

(ferrule to DIN 46 228)mm2 1

x

(0.75 – 1.5)1

x

(0.75 – 4)1

x

(1.5 – 25)1

x

(1.5 – 25)1

x 50 (50)2) 120

mm2 2

x

(0.75 – 1.5)2

x

(0.75 – 4)2

x

(1.5 – 10)2

x

(1.5 – 10)2

x 16 –

Flat conductor connection mm2 – – – – – 1 busbar25

x 53)

2 busbars20

x 33)

Terminal screw M3.5 M4 M6 M6 (counter-sunk M5)2)

M12

Max. tightening torque Nm 1 1.5 4 5.6(14)2)

25

T0-1-...toT0-4-...

T3-1-toT3-6-

T5B-... T5-... T6-...(T6-160-6)

T8-3-8342

Switch-disconnector(Main switches)Switching angles 90° 90° 90° 90° 90° 90°Max. number of switch positions 2 2 2 2 2 2Max. number of contactsfor isolating characteristics to IEC/EN 60 947

8 12 20 20 3 (6)2) 6

Isolating characteristics to IEC/EN 60 947 Up to V AC 500 500 690 690 690 690

Notes 1) T0(3), (6), (8)...: Max. 2 cross-section sizes difference admissible between 2 conductorsT5(B)-...: Max. 1 cross-section size difference admissible between 2 conductors

2) For T6-160-6/...3) For T8-3-8342/...4) T3-.../I... > 12 g5) T5-4-8344/I5: max. 95 A6) Enclosed version: max. 275 A

Page 63: 07/000 T Rotary Switches, P Switch-Disconnectors · Moeller HPL0211-2001/2002 T Rotary Switches, P Switch-Disconnectors Overview of Functions Rotary Switches Switch-Disconnectors

Rota

ry S

wit

ches

Swit

ch-D

isco

nnec

tors

07/091Moeller HPL0211-2001/2002

T Rotary SwitchesTechnical Data

T0-... T3-... T5B-... T5-... T6-...(T6-160-6)

T8-...

Switching capacityAC

Rated making capacity cos

v = 0.35 A 130 320 800 950 1600 2390Rated breaking capacity 230 V AC, cos

v = 0.35 A 100 260 520 760 1280 1910Motor load switches 400 V AC, cos

v = 0.35 A 110 260 600 740 900 1800500 V AC, cos

v = 0.35 A 80 240 480 590 880 1200690 V AC, cos

v = 0.35 A 60 170 340 420 340 420AC-21A Load-break switches Rated operational current

Ie380 – 440 V, 3

hA 20 32 63 100 125 (160) 315

AC-3 Motor load switches,for operationalswitchingStar-delta valuesY

d : for star-deltaswitches without automatic spring-return

220 – 240 V, 3

h kW 3 6.5 15 18.5 22 37220 – 240 V, Y

d kW 4 11 22 30 22 37380 – 440 V, 3

h kW 4 12 22 30 37 (45) 55380 – 440 V, Y

d kW 5.5 18.5 37 45 37 (45) 55500 V, 3

h kW 5.5 15 22 37 37 37500 V, Y

d kW 7.5 22 37 55 37 37660/690 V, 3

h kW 4 15 22 30 22 37660/690 V, Y

d kW 5.5 22 37 45 22 37AC-23A Motor load switches

(main switches,maintenance switches)

220 – 240 V, 3

h kW 3.5 7.5 18.5 18.5 37 75380 – 440 V, 3

h kW 6.5 13 22 30 45 (55) 132500 V, 3

h kW 7.5 15 22 37 55 75660/690 V, 3

h kW – – 22 30 30 37AC-15 Control switches Rated operational current

Ie220 – 240/380 – 415/500 V

A 6/4/2 10/6/4 16/6/4 16/6/4 – –

DCDC-1 Load-break switches

L/R = 1 msRated operational current

Ie A 10 25 63 80 125 315

Voltage per contact pair in series

V 60 60 60 60 42 42

DC-21A 240 V A 1 (1) 1 (1) – – – –DC-23A Motor load switches

L/R = 15 ms

Figures in brackets:number of contacts to be switched in series

24 V A 10 (1) 25 (1) 50 (1) – 125 (1) 250 (1) 48 V A 10 (2) 25 (2) 50 (2) – 125 (2) 250 (2) 60 V A 10 (3) 25 (3) 50 (3) – 125 (3) 125 (3)120 V A 5 (3) 12 (3) 25 (3) – 50 (3) 50 (3)240 V A 5 (5) 10 (5) 20 (6) – – –

DC-13 Control switchesL/R = 50 ms

Rated operational current

Ie A 10 20 25 – 125 250

Voltage per contact pair in series

V 32 32 24 – 24 –

Control circuit reliability at24 V DC, 10 mA

Fault probability HF < 10−5, < 1 fault in 100000 operations

T6-160-6/...T8-3-8342/...

Auxiliary contacts

Standards Control circuit isolator to IEC/EN 60 947-5

Rated insulation voltage

Ui V AC 500Rated uninterrupted current

Iuwith max. cable connected

A 10

Rated operational current

Ie AC-15 with 220 –240/380 – 415/500 V

A 6/4/3

Short-circuit rating without welding,Max. fuse

A gG/gL 10

Terminal capacity Min. solid or flexible mm2 0.75/0.5Max. solid or flexible mm2 2.5/1.5

Max. tightening torque Nm 0.35Control circuit reliability at24 V DC, 10 mA

Fault probability HF < 10−5, < 1 fault in 100 000 operations

Page 64: 07/000 T Rotary Switches, P Switch-Disconnectors · Moeller HPL0211-2001/2002 T Rotary Switches, P Switch-Disconnectors Overview of Functions Rotary Switches Switch-Disconnectors

Moeller HPL0211-2001/2002

P Switch-DisconnectorsTechnical Data

Rota

ry S

witc

hes

Swit

ch-D

isco

nnec

tors

07/092

P1-25 P1-32 P3-63 P3-100

General technical dataStandards IEC/EN 60 947, VDE 0660, IEC/EN 60 204, CSA, UL

Switch-disconnector to IEC/EN 60 947-3Lifespan, mechanical Operations 3

x 105 3

x 105 105 105

Max. operating frequency Ops./h 50 50 50 50Climatic proofing Damp heat, constant, to IEC 60 068 Part 2-3

Damp heat, cyclical, to IEC 60 068 Part 2-30Ambient temperature Open Min./Max. °C −25/+50 −25/+50 −25/+50 −25/+50

Enclosed Min./Max. °C −25/+40 −25/+40 −25/+40 −25/+40Mounting position As requiredDimensions

a Page 07/104Weight

a Page 15/023Mechanical shock resistance (half-sinusoidal shock 20 ms) g > 20 > 20 > 20 > 20ContactsRated operational voltage

Ue V AC 690 690 690 690Rated impulse withstand voltage Uimp V 6000 6000 6000 6000Overvoltage category/pollution degree III/3 III/3 III/3 III/3Rated uninterrupted current

Iu with max. cable connected A 25 32 63 100Load-carrying capacity in intermittent operation, Class 12, AB 60/40/25 % DF

x

Ie 1.3/1.6/2 1.3/1.6/2 1.3/1.6/2 1.3/1.6/2 Short-circuit rating Max. fuse A gG/gL 25 50 80 100Rated short-time withstand current (1 s current)

Icw Arms 640 640 1260 2000Isolating characteristics to IEC/EN 60 947 Up to VAC 690 690 690 690

Safe isolation to IEC 536 between the main contacts and the auxiliary contacts V AC 440 440 440 440Protection against direct contact Finger and back-of-hand proof to IEC 536

Switching angles 90° 90° 90° 90°Contacts (current paths) Max. 3(+N) 3(+N) 3(+N) 3(+N)Current heat loss per contact at

Ie W 1.1 1.8 4.5 7.5Terminal capacitySolid or stranded1) mm2 1 × (1.5 – 6) 1 × (1.5 – 6) 1 × (2.5 – 35) 1 × (2.5 – 35)

mm2 2 × (1.5 – 6) 2 × (1.5 – 6) 2 × (2.5 – 10) 2 × (2.5 – 10)Flexible with ferrule1)

(ferrule to DIN 46 228)mm2 1 × (1 – 4) 1 × (1 – 4) 1 × (1.5 – 25) 1 × (1.5 – 25)mm2 2 × (1 – 4) 2 × (1 – 4) 2 × (1.5 – 6) 2 × (1.5 – 6)

Terminal screw M4 M4 M5 M5Max. tightening torque Nm 1.6 1.6 4 4

Notes Main switch characteristics to IEC/EN 60 204; positive opening of contacts, operator element positively located on shaft

1) P1-...:Max. 2 cross-section sizes difference admissible when using 2 conductorsP3-...:Max. 1 cross-section size difference admissible when using 2 conductors

Page 65: 07/000 T Rotary Switches, P Switch-Disconnectors · Moeller HPL0211-2001/2002 T Rotary Switches, P Switch-Disconnectors Overview of Functions Rotary Switches Switch-Disconnectors

Rota

ry S

wit

ches

Swit

ch-D

isco

nnec

tors

07/093Moeller HPL0211-2001/2002

P Switch-DisconnectorsTechnical Data

P1-25 P1-32 P3-63 P3-100

Switching capacityAC

Rated making capacity cos

v = 0.35 A 240 320 800 950Rated breaking capacity 230 V AC, cos

v = 0.35 A 190 260 640 760Motor load switches 400 V AC, cos

v = 0.35 A 150 300 600 740500 V AC, cos

v = 0.35 A 170 290 590 880690 V AC, cos

v = 0.35 A 150 250 340 520AC-21A Load-break switches Rated operational current

Ie380 – 440 V, 3

hA 25 32 63 100

AC-3 Motor load switches,for operationalswitching

220 – 240 V, 3

h kW 5.5 7.5 15 22380 – 440 V, 3

h kW 7.5 13 30 37500 V, 3

h kW 7.5 18.5 30 45660/690 V, 3

h kW 7.5 15 30 37AC-23A Motor load switches

(main switches,maintenance switches)

220 – 240 V, 3

h kW 7 8.5 18.5 30380 – 440 V, 3

h kW 13 15 37 50500 V, 3

h kW 11 18.5 37 65660/690 V, 3

h kW 11 18.5 30 75DC

DC-1 Load-break switchesL/R = 1 ms

Rated operational current

Ie A 25 32 63 100

Voltage per contact pair in series

V 60 60 60 60

DC-23A Motor load switchesL/R = 15 ms

Figures in brackets:number of contacts to be switched in series

24 V A 25 (1) 25 (1) 50 (1) 50 (1)48 V A 25 (2) 25 (2) 50 (2) 50 (2)60 V A 25 (3) 25 (3) 50 (3) 50 (3)120 V A 12 (3) 12 (3) 25 (3) 25 (3)

N-P1... N-P3...

Switched neutralSwitching capacity As P1-32 As P3-100

HI11-P1/P3

Auxiliary contacts

Standards Control circuit isolator to IEC/EN 60 947-5

Rated insulation voltage

Ui V AC 500Rated uninterrupted current

Iu with max. cable connected A 10Rated operational current

Ie AC-15 220 – 240/380 – 415/500 V A 6/4/3DC-13 250 V DC A 0.55

125 V DC A 1.1Short-circuit rating without welding,Max. fuse A gG/gL 10Terminal capacity Min. solid or flexible mm2 0.75/0.5

Max. solid or flexible mm2 2.5/1.5Max. tightening torque Nm 0.6Control circuit reliability at24 V DC, 10 mA

Fault probability HF < 10−5, < 1 fault in 100 000 operations

Page 66: 07/000 T Rotary Switches, P Switch-Disconnectors · Moeller HPL0211-2001/2002 T Rotary Switches, P Switch-Disconnectors Overview of Functions Rotary Switches Switch-Disconnectors

Moeller HPL0211-2001/2002

T Rotary Switches, P Switch-DisconnectorsTripping Characteristics

Rota

ry S

witc

hes

Swit

ch-D

isco

nnec

tors

07/094

Component lifespan in relation to breaking current and utilization category 1)

In order to achieve a reasonable lifespan in utilization category AC-4 (severe duty: 100 % inching, reversing or plugging), the stalled motor current should not exceedthe rated current of the switch at AC-21.

Notes 1) AC-3 and AC-21 at 400 V, AC-15 at 230 V

1 2 3 4 5 6 7 8 10 20 A

T0

0.5

1

2

3

4568

10

Com

pone

nt li

fesp

an (o

pera

tions

10

)

5

Breaking pointAs control switch (AC-15)As motor load switch (AC-3)As load-break switch (AC-21)

Breaking pointAs motor load switch (AC-3)As load-break switch (AC-21)

T3

Com

pone

nt li

fesp

an (o

pera

tions

10

)

5

1 2 3 4 6 128 30 40 A0.5

1

2

3456

8

10

16 20 25

0.6

0.8

Breaking pointAs motor load switch (AC-3)As load-break switch (AC-21)

T5B, T5

Com

pone

nt li

fesp

an (o

pera

tions

10

)

5

1 2 3 4 6 128 30 400.5

1

2

3456

8

10

16 20

0.6

0.8

60 80 100 A

T5B

T5B T5

T5

T5B T5

T5B T5

Breaking pointAs motor load switch (AC-3)As load-break switch (AC-21)

T6, T8

Com

pone

nt li

fesp

an (o

pera

tions

10

)

5

4 6 8 16120.1

0.2

0.3

0.5

1

2

3

5

6020 30 40 100 250A

T6 T8

T6 T8

T6

T8

T6

T8

Breaking pointAs motor load switch (AC-3)As load-break switch (AC-21)

P1

Com

pone

nt li

fesp

an (o

pera

tions

10

)

5

1 2 3 4 6 128 30 40 A0.5

1

2

3456

8

10

16 20 25

0.6

0.8

P1-32

P1-25

P1-25 P1-32

P1-25

Breaking pointAs motor load switch (AC-3)As load-break switch (AC-21)

P3

Com

pone

nt li

fesp

an (o

pera

tions

10

)

5

1 2 3 5 2010 80 100 A0.1

40 60

0.2

0.3

0.40.50.6

0.81

2

P3-100P3-63

P3-63 P3-100

P3-100

P3-63

Page 67: 07/000 T Rotary Switches, P Switch-Disconnectors · Moeller HPL0211-2001/2002 T Rotary Switches, P Switch-Disconnectors Overview of Functions Rotary Switches Switch-Disconnectors

Rota

ry S

wit

ches

Swit

ch-D

isco

nnec

tors

07/095Moeller HPL0211-2001/2002

TM Mini Rotary SwitchesTechnical Data

General technical dataStandards IEC/EN 60 947, UL, CSA

Control switches to IEC/EN 60 947-5-1Control circuit isolators to IEC/EN 60 947-5-1

Control circuit isolators (IEC/EN 60 947-5-1) Maximum 6 contacts; switching angle 90°

Lifespan, mechanical Operations Ops. > 1

x 106

Max. operating frequency Ops./h 3000Climatic proofing Damp heat, constant, to IEC 60 068 Part 2-3

Damp heat, cyclical, to IEC 60 068 Part 2-30Ambient temperature Open Min./Max. °C −25/+50

Enclosed Min./Max. °C −25/+40Mounting position As requiredMechanical shock resistance (shock duration 20 ms) g > 15Protection against direct contact Finger and back-of-hand proof to IEC 536

Terminal capacity Solid 1 conductor Min./Max. mm2 0.75/1.52 conductors Max. mm2 1.5 (AWG 14)

Flexible 1 conductor Min. mm2 0.75 (AWG 18)2 conductors Max. mm2 0.75

Terminal screw M2.5Max. tightening torque Nm 0.35Dimensions

a Page 07/108

ContactsMechanical values

Contacts Max. 16Contact units Max. 8Switching angles 90°/60°/45°/30°Min. switching angle for On-Off-On 60°Switch positions Max. 12Thickness of gold coating

mm 35Electrical values

Rated operational voltage

Ue V AC 500Rated impulse withstand voltage

Uimpapplicable to systems with earthed neutral point kV 4 Overvoltage category/pollution degree III/3Rated insulation voltage

Ui V AC 500 (UL/CSA 300 V AC)Rated uninterrupted current

Iu with max. cable connected A 10Switching capacity

AC-23AMotor load switches

220 – 240 V, 3

h kW 1.8380 – 440 V, 3

h kW 3500 V, 3

h kW 3.7220 – 240 V, 1

h kW 0.75380 – 440 V, 1

h kW 1.1AC-15Control switches

220 – 240 V, 1

h A 2.5380 – 415 V, 1

h A 1.5440 V, 1

h A 1DC-1Load-break switches

1 – 24 V DC A 10110 – 240 V DC A 0.7 – 0.3

DC-13Control switches

L/R = 50 msMax. 32 V DC per contact

A 3

Switching capacity for North America240 V, 3

h HP 1277 V, 1

h HP

o

300 V AC A 10 Heavy dutyShort-circuit protective device

Maximum fuse A gG/gL 10Control circuit reliability

24 V DC, 10 mA Fault probability

HF < 10−5, < 1 fault in 100 000 operations

Page 68: 07/000 T Rotary Switches, P Switch-Disconnectors · Moeller HPL0211-2001/2002 T Rotary Switches, P Switch-Disconnectors Overview of Functions Rotary Switches Switch-Disconnectors

Moeller HPL0211-2001/2002

T0, T3 Rotary Switches Dimensions

Rota

ry S

witc

hes

Swit

ch-D

isco

nnec

tors

07/096

Flush mounting

T0.../E (+ H3-T0)T3.../E (+ H3-T0)

Drilling dimensions

Centre mounting

T0.../EZ (/OFS)T3.../EZ (/OFS) T0 T3 Drilling dimensions

T.../EZ/OFS

48

48

ZFS-...-T0

17

525 101

c20 35

H3-T0

75

90

10 –

11

3.1 – 3.5

12.2

30

48

4817

1.5 – 5

c21 35

45

48

48 54

61

3.2

24.1

+0.

4 0

22.3 +0.4 0

35

29

Type c20 c21T0-1...T0-2...T0-3...T0-4...T0-5...T0-6...T0-7...T0-8...T0-9...T0-10...T0-11...

41506069798898107117126136

6170808999108118127137146156

Depth of one contact unit: 9.5 mm

Type c20 c21T3-1...T3-2...T3-3...T3-4...T3-5...T3-6...T3-7...T3-8...T3-9...T3-10...T3-11...

4456677990102113125136148159

64768799110122133145156168179

Depth of one contact unit: 11.5 mm

Page 69: 07/000 T Rotary Switches, P Switch-Disconnectors · Moeller HPL0211-2001/2002 T Rotary Switches, P Switch-Disconnectors Overview of Functions Rotary Switches Switch-Disconnectors

Rota

ry S

wit

ches

Swit

ch-D

isco

nnec

tors

07/097Moeller HPL0211-2001/2002

T0, T3 Rotary Switches Dimensions

Service distribution board mounting

T0.../IVS Drilling dimensionsBase

T3.../XZ + IVS-T0 Drilling dimensionsBase

Rear mounting

T0.../ZT3.../Z

Drilling dimensions Base

Drilling dimensionsDoor

� Can be extendedusing ZVV-T0,

F 4

x 25 = 100 mm

54

5545 M4 50

48

60 50

� 5

� 528

45

55c22

5

63

6545

54

M4 65

5

� 5

48

75 65

63

28

45

55c22

5 �

548

4817

ZFS-...-T0

M450

5 – 5.5

36

36

5 – 5.5

3636M465

48

50 60

63

65 7555

5 5

25

c23c24 35

O 5

O

O

O

5

5

38,ZAV:

54154

22.3 + 0.4 0

22.3 + 0.4 0

100R

a

T3

T0

Type c20 c21 c22 c23 c24f/F

c24 with

F 4 ZAVc25

T0-1...T0-2...T0-3...T0-4...T0-5...T0-6...T0-7...T0-8...T0-9...T0-10...T0-11...

41506069798898107117126136

6170808999108118127137146156

778796106115125134144154163173

485767768695105114124133143

86 – 10296 – 112105 – 121115 – 131124 – 140134 – 150143 – 159153 – 169162 – 178172 – 188181 – 197

202212221231240250259269278288297

72729191–––––––

Depth of one contact unit: 9.5 mm

Type c20 c21 c22 c23 c24f/F

c24 with

F 4 ZAVc25

T3-1...T3-2...T3-3...T3-4...T3-5...T3-6...T3-7...T3-8...T3-9...T3-10...T3-11...

4456677990102113125136148159

64768799110122133145156168179

8092103115126138149161172184195

5163748697109120132143155166

86 – 105101 – 115112 – 128124 – 139135 – 151147 – 162158 – 174170 – 185181 – 196193 – 208204 – 219

205216228239251262274285296308319

7979101101–––––––

Depth of one contact unit: 11.5 mm

Page 70: 07/000 T Rotary Switches, P Switch-Disconnectors · Moeller HPL0211-2001/2002 T Rotary Switches, P Switch-Disconnectors Overview of Functions Rotary Switches Switch-Disconnectors

Moeller HPL0211-2001/2002

T0, T3 Rotary Switches Dimensions

Rota

ry S

witc

hes

Swit

ch-D

isco

nnec

tors

07/098

Flush mounting main switches

T0.../EA/SVBT3.../EA/SVB

Drilling dimensionsDoor

T0

T3

Rear mounting main switches

T0.../V/SVBT3.../V/SVB

Drilling dimensions Base

Drilling dimensionsDoor

� Interlock can be extended using ZVV-T0 + ZAV-T0,

F 4

x 25 = 100 mm

T0

T3

Sheet steel enclosures

T0-.../ST, P1-.../ST P3-.../ST

T3-.../ST, T5(B)-.../ST

65

3317

48

ON

OFF

OFF

I

o

o

25 c2035

5ZFS-...T0

61

54

49

45

3.1 – 3.5

30

10 –

11

12.2

I

o

o

65

3317

48ZFS-...T0

55 25

c23c24 35

38, 54 ZVV+ZAV: 154

100R

ON

OFF

OFF

� 65 7563

5

5

M465

M450

50 60

49

� 522.3 + 0.4 0

5 – 5.5

36

36

M20

M4

174

M20162

60

104

130

M4

184

M20

M25

M25

M20

184

140

184

140

M4

284

M25

M32

M25

184 193

140

140

Page 71: 07/000 T Rotary Switches, P Switch-Disconnectors · Moeller HPL0211-2001/2002 T Rotary Switches, P Switch-Disconnectors Overview of Functions Rotary Switches Switch-Disconnectors

Rota

ry S

wit

ches

Swit

ch-D

isco

nnec

tors

07/099Moeller HPL0211-2001/2002

T0, T3 Rotary Switches Dimensions

Surface mounting

T0.../I1 Drilling dimensionsBase

T3.../I2 Drilling dimensionsBase

Surface mounting main switches

T0.../I1/SVBDrilling dimensionsBase

T3.../I2/SVB Drilling dimensionsBase

F 3 padlocks

L-...

80

120

33.5

c25 27

137 M20

127

M4

L-...

100

160

35.5

c25 c33

180 M25

∅8

171

M4

L-...

80

120

33.5

c25 35

M20

137

I

OFFo

ON

oOFF 12

7

M4

L-...

100

160

33.5

180

35c25

M25

�8

I

OFFo

ON

oOFF

d b

d = 4 – 8 mmb + d F 47 mm

171

M4

Type c25T0-1...T0-2...T0-3...T0-4...

75759595

Type c25 c33T3-1...T3-2...T3-3...T3-4...T3-5...

8080100100145

2727353535

Page 72: 07/000 T Rotary Switches, P Switch-Disconnectors · Moeller HPL0211-2001/2002 T Rotary Switches, P Switch-Disconnectors Overview of Functions Rotary Switches Switch-Disconnectors

Moeller HPL0211-2001/2002

T0, T3 Rotary Switches, AccessoriesDimensions

Rota

ry S

witc

hes

Swit

ch-D

isco

nnec

tors

07/100

Key operation

S-T0S-SOND...-T0

T0.../E(I1) + S-(SOND-)T0T3.../E(I2) + S-(SOND-)T0

T0.../Z + S-(SOND-)T0T3.../Z + S-(SOND-)T0

T0.../EZ � T0../E + EZ-T0 + S-(SOND-)T0T3.../EZ � T3../E + EZ-T0 + S-(SOND-)T0

Cylinder lock

SVA-T3 T0.../I1/SVAT3.../I2/SVA

T0.../E/SVA...T3.../E/SVA...

T0.../Z/SVA...T3.../Z/SVA...

Push-button interlockPadlocking feature Dimensions as DTV-T3

DTV-T3SVC-T3

T0.../I1/DTVT3.../I2/DTVT0.../I1/SVCT3.../I2/SVC

T0.../E/DTV...T3.../E/DTV...T0.../E/SVC...T3.../E/SVC...

T0.../Z/DTV...T3.../Z/DTV...T0.../Z/SVC...T3.../Z/SVC...

Mounting clearance

� Mounting clearances a and b: 4 mm� Exposed conductive part (metal)

17

27

48

48

ZFS-...-T0

1930

5

36

12.2

3.1 – 3.5

30

10...

11

527

44

5 – 5.5

36

36

22.3 + 0.4 0

100R

2 – 5

c20 22:25 – 28 30:23 – 26

3.2

30.5

17

3.2 12.5

��

22.3 + 0.4 0

73

48

ZFS...-T0 56

73

46 30

5673

46 30

56

73

46 30

73

48

ZFS...-T0 56

73

46

48

56

73

46

48

56

73

46

48

b

a

a

b

Page 73: 07/000 T Rotary Switches, P Switch-Disconnectors · Moeller HPL0211-2001/2002 T Rotary Switches, P Switch-Disconnectors Overview of Functions Rotary Switches Switch-Disconnectors

Rota

ry S

wit

ches

Swit

ch-D

isco

nnec

tors

07/101Moeller HPL0211-2001/2002

T5B, T5 Rotary SwitchesDimensions

Flush mounting

T5(B).../E Drilling dimensionsDoor

Rear mounting

T5(B).../Z Drilling dimensionsBase

Drilling dimensionsDoor

� Shaft can be extended using ZAV-P3,

F 4

x 25 = 100 mmFlush mounting main switches

T5(B).../EA/SVBDrilling dimensionsDoor

Rear mounting main switches

T5(B).../V/SVB Drilling dimensionsBase

Drilling dimensionsDoor

� Can be extendedusing ZVV-P3,

F 4

x 25 = 100 mm

88

8827

ON

OFF

I

o

18

c2

86

37

514

37

4.1 – 4.5

12 – 13

ON

OFFo

I

88

8827

48

5 – 5.5

48

30.5

c20

c2 37

2525

5

38, 54 ZAV: 154

7973 86

� 6.4

100R

a

88

2788

ON

OFF

OFF

I

o

o

5

25c2

88

80/9

0

40.516.5

44

100

80/9

0

14

37

4.1 – 4.5

12 – 13

ON

OFF

OFF

o

I

o

48

5 – 5.5

48

30.5 48

5 – 5.5

48

30.5

2788

88

1216.5

5c20

5

25 25

40.5

44

100

80/9

0

73

85

100R�

Page 74: 07/000 T Rotary Switches, P Switch-Disconnectors · Moeller HPL0211-2001/2002 T Rotary Switches, P Switch-Disconnectors Overview of Functions Rotary Switches Switch-Disconnectors

Moeller HPL0211-2001/2002

T5B, T5 Rotary SwitchesDimensions

Rota

ry S

witc

hes

Swit

ch-D

isco

nnec

tors

07/102

Surface mounting

T5(B).../I4 T5.../I5

Surface mounting main switches

T5(B).../I4/SVB Drilling dimensions

F 3 padlocks

T5.../I5/SVB Drilling dimensions

External fixing bracket

160 c22 37

M20

M25M32

240

33.5 33

.5

280

L-...

200 c22 37

L-...

M20

M25M50

L-...

160

240

33.5

c22 44

193

142

M5

I

OFFo

ON

oOFF

d b

d = 4 – 8 mmb + d F 47 mm

280

33.5

L-...

200 c22 44

233

182

M5

I

OFFo

ON

oOFF

Type c2 c20f/F

c24 with

F 4 ZAVc21 c22

T5(B)-1...T5(B)-2...T5(B)-3...T5(B)-4...

547187104

92 – 107109 – 124125 – 140142 – 157

207224240257

9090123123

125 (95)125 (95)160 (160)160 (160)

T5(B)-5...T5(B)-6...T5(B)-7...T5(B)-8...T5(B)-9...T5(B)-10...

120137153170186203

158 – 173175 – 190191 – 206208 – 223224 – 239240 – 356

273290306323339356

––––––

––––––

Depth of one contact unit: 16.5 mm

The rotary switches T5B and T5 are of identical designbut differ in their contacts

20 5.5 6.2

7.5

5

2.5

M5

∅6

50

34

4.6

7.8

6

Page 75: 07/000 T Rotary Switches, P Switch-Disconnectors · Moeller HPL0211-2001/2002 T Rotary Switches, P Switch-Disconnectors Overview of Functions Rotary Switches Switch-Disconnectors

Rota

ry S

wit

ches

Swit

ch-D

isco

nnec

tors

07/103Moeller HPL0211-2001/2002

T6, T8 Rotary SwitchesDimensions

Flush mounting

T6.../ET8.../E

Flush mounting main switches

T6-2/EA/SVB

Rear mounting main switches

T6-2/V/SVB

F 3 padlocks for T.../SVB

T6-160-6/V/SVB-SW/HI11 T8-3-8342/V/SVB-SW/HI11

Drilling dimensionsDoor

T6: 4 M5

x 20T8: 4 M6

x 20

15058

5c2 c30

b2

a2

88

88

90

125

ZS

5.4

68

68 88

88 5

100 50

88

88

90

125

ZS

5.4

68

68 88

884.5 5

110 50

40100 300

R

d b

d = 4 – 8 mmb + d F 47 mm

9

88

73

5.5 1

93 216 200

5

76224

6.4 H-T6-100

118

22

68108

100R

7

130

250

1044.5

172.8

315 218

9.2

86.5

7 1

130

68H-T8

19

100R

Type a2 b2 c2 2 BE 3 BE c30 d1 d2 x1 y1BE = Number of contact units

T6...T8.../ET8.../SVB

88130–

88130–

100––

152173–

4462–

∅ 26–30∅ 22–25∅ 38–42

∅ 6.0∅ 7.0∅ 7.0

6810468

6810468

d2

d1

x1

y1

Page 76: 07/000 T Rotary Switches, P Switch-Disconnectors · Moeller HPL0211-2001/2002 T Rotary Switches, P Switch-Disconnectors Overview of Functions Rotary Switches Switch-Disconnectors

Moeller HPL0211-2001/2002

P Switch-DisconnectorsDimensions

Rota

ry S

witc

hes

Swit

ch-D

isco

nnec

tors

07/104

Flush mountingP.../E

Centre mounting

P1.../EZ Drilling dimensionsDoorP1-.../E P1-.../EZ P3-.../E

Service distribution board mounting

P3.../IVS

F 3 padlocks

P1.../IVS

Rear mounting

P.../Z

� Shaft can be extended using ZAV-...,

F 4

x 25 = 100 mm

Drilling dimensionsBaseP1.../Z

P3.../Z

Drilling dimensionsDoor

ON

0

I

OFF

a2

b2b2

2

b3

a3

L3 L1

T3 T1

L2

T2

1

2

3

4

5

6

5c2 c21

P1.../EZ = c2 + 5 mm

4.1 – 4.53.2

22.3 +0.40

12.5

10 –

11

12.2

3.1 – 3.5

30

14

37

12 – 13

b3

a4

c22c23

c3

5

45

N

HI11

L3L2L1

T3T2T1

L3L2L1

T3T2T1

a32 a32

a31

d b

d = 4 – 8 mmb + d F 47 mm

49

L1 L2 L3

T1 T2 T3

55

28

b3 45

5 c3

38154

3

5

a3

5

b22

b2

a2

c21c25c20

R 100

c31 c32b3

5 – 5.5

M4 65 36

36

22.3 +0.40

M4 75

25

5 – 5.5

48

48

30.5

Type a2 a3 a4 a21 a22 a23 a31 a32 a33 b2 b3 b21 b22 b23 b24 b31P1P3

4887

4972

53.571.5

6587

4887

87125

1518

1515

83114

4887

7083

6587

1727

125175

32–

4960

Type c2 c3 c20f/

F

c20 with

F4ZAV/ZVV

c21 c22 c23 c24 c25 c27 c28 c31 c32 c33

P1P3

5959

8682

96 – 112103 – 118

212218

3537

3241

6563

6881

5865

3544

7790

2525

2525

2729

Page 77: 07/000 T Rotary Switches, P Switch-Disconnectors · Moeller HPL0211-2001/2002 T Rotary Switches, P Switch-Disconnectors Overview of Functions Rotary Switches Switch-Disconnectors

Rota

ry S

wit

ches

Swit

ch-D

isco

nnec

tors

07/105Moeller HPL0211-2001/2002

P Switch-DisconnectorsDimensions

Flush mounting main switches

P.../EA/SVB Drilling dimensionsDoor

P1... P3...

Rear mounting main switches

P.../V/SVB

� Interlock can be extended using ZVV-T0 + ZAV-T0,

F 4

x 25 = 100 mm

Drilling dimensionsBase

P1.../V/SVB

P3.../V/SVB

Drilling dimensionsDoor

Surface mounting

P1.../I2

Surface mounting main switches / safety switchesP1.../I2/SVBP1.../I2/SI

Drilling dimensions

5

b3

a3

ON

OFF

b22

ZFS-....

c27c225

o

o OFF

I 1

2

3

4

5

6

N

N y

y

a22

b21

a21

b31

H-P...

14

4.1 – 4.5

10 –

11

12.2

3.1 – 3.5

30 37

12 – 13

5

38 154

3

R 100

I ON

OFF

OFF

ZFS-.... 5

b3

c 27

o

o

1

2

3

4

5

6

N

N

a 22

b22

b31

b21

a 21 a 3 c 25

c 20

H-P... �5 – 5.5

M4 65 36

36

22.3 +0.40

M4 75

25

5 – 5.5

4848

30.5

L-...

a23

160

b24

c28 c33

M25

171

c27

M4

b23

M25M258

Page 78: 07/000 T Rotary Switches, P Switch-Disconnectors · Moeller HPL0211-2001/2002 T Rotary Switches, P Switch-Disconnectors Overview of Functions Rotary Switches Switch-Disconnectors

Moeller HPL0211-2001/2002

P Switch-DisconnectorsDimensions

Rota

ry S

witc

hes

Swit

ch-D

isco

nnec

tors

07/106

Surface mountingP3-63/I4

Surface mounting main switches/safety switchesP3-63/I4/SVBP3-63/I4/SIT5B-.../I4/SI

Drilling dimensions

Surface mounting

P3-100/I5

Surface mounting main switches/safety switchesP3-100/I5/SVBP3-100/I5/SIT5-.../I5/SI

Drilling dimensions

L-...

a23

L—PKZ0

95 37

b23

b24

95 44

193

142

M5

M25M32 M20

L-...

a23 125 37 125 44

233

182

M5

L—PKZ0

M25M50 M20

b23

b24

Type a2 a3 a4 a21 a22 a23 a31 a32 a33 b2 b3 b21 b22 b23 b24 b31P1.../I2P3-63/I4P3-100/I5

488787

497272

53.571.571.5

658787

488787

100160200

151818

151515

83114114

488787

708383

658787

172727

180240280

35.535.535.5

496060

Type c2 c3 c20f/

F

c20 with

F4ZAV/ZVV

c21 c22 c23 c24 c25 c27 c28 c31 c32 c33

P1...P3-63P3-100

595959

868282

96 – 112103 – 118103 – 118

212218218

353737

324141

656363

688181

586565

354444

80125125

252525

252525

273737

Page 79: 07/000 T Rotary Switches, P Switch-Disconnectors · Moeller HPL0211-2001/2002 T Rotary Switches, P Switch-Disconnectors Overview of Functions Rotary Switches Switch-Disconnectors

Rota

ry S

wit

ches

Swit

ch-D

isco

nnec

tors

07/107Moeller HPL0211-2001/2002

P Switch-Disconnectors, AccessoriesDimensions

Cylinder lock

SVA-T3 P1.../I2/SVA P1.../E/SVA P1.../Z/SVA

Padlocking feature

SVC-T3 P1.../I2/SVC P1.../E/SVC P1.../Z/SVC

ModulesSwitched neutral N-P...HI 11-P1/P3 auxiliary contacts

F 3 padlocks

73

48

ZFS...-T0 56

73

46 30

56

73

46 30

56

73

46 30

73

48

ZFS...-T0 5673

46

48

56

73

46

48

56

73

46

48

L3 L2 L1

T3 T2 T16 4 2

5 3 1 b31

a3

N-P

H-P...

HI 11

N

N

1 3

2 4 6

a32 a31 a32 a32 a31 a32

a33

5

Type a3 a31 a32 a33 b31P1-...P3-..

4972

1518

1515

83114

4960

d b

d = 4 – 8 mmb + d F 47 mm

Page 80: 07/000 T Rotary Switches, P Switch-Disconnectors · Moeller HPL0211-2001/2002 T Rotary Switches, P Switch-Disconnectors Overview of Functions Rotary Switches Switch-Disconnectors

Moeller HPL0211-2001/2002

TM Mini Rotary SwitchesDimensions

Rota

ry S

witc

hes

Swit

ch-D

isco

nnec

tors

07/108

Flush mounting

TM.../E Drilling dimensions

Control circuit isolatorsLockable using 2 padlocks ∅ 4 mm or 1 padlock ∅ 6 mm

TM-.../E/SVB(-SW) Drilling dimensions

Centre mounting

TM-.../EZ Drilling dimensions1)

Centre mounting with key operation

TM-...+EZ/S-.. Drilling dimensions1)

Service distribution board mounting

TM-.../IVS

Notes 1)) Drilling dimension options: 16.2 mm = use without adapter � RMQ16; 22.3 mm = adapter required � RMQ-Titan

28

c20

3

� 4

.8

30

30

28

28

M3 M33.2

20

8

48

48

28

c21

3

35

38

38

M4 M4

104.2

30

F 5.5

2830

17/19

1.7

17.9

3.2

24.1

+0.

4 0

22.3 +0.4 0

16.2 +0.2 0

30

30

5.5

28

c20 3512

17/19

1.7

17.9

3.2

24.1

+0.

4 0

22.3 +0.4 0

16.2 +0.2 0

Type c20 c21TM-1...TM-2...TM-3...TM-4...TM-5...TM-6...TM-7...TM-8...

395163758799111123

425466

Depth of one contact unit: 12 mm

S H35

60

45

AUTOHAND

O Type S HTM-1...TM-2...

4446

2126.5

Depth of one contact unit: 12 mm

Page 81: 07/000 T Rotary Switches, P Switch-Disconnectors · Moeller HPL0211-2001/2002 T Rotary Switches, P Switch-Disconnectors Overview of Functions Rotary Switches Switch-Disconnectors

Rota

ry S

wit

ches

Swit

ch-D

isco

nnec

tors

07/109Moeller HPL0211-2001/2002

P..., T5..., P7 Safety SwitchesEngineering Notes

Maintenance and safety switches have the same electrical function. They are designed to isolate electrical installations (loads) safely from the mains while maintenance work or repairs are being carried out, thereby ensuring that no hazard arises to personnel, machinery or product.The safety switch is an additional, enclosed main switch = isolator for an individual electrical load, and can be fitted directly next to the motor or the electrical load, ensuring that work on them can be carried out safely provided the 5 safety rules to VDE 0105 are observed. This is of special importance if there is any possibility whatsoever of the main switch being wrongly identified.

ApplicationBy securing the switch in the Off position with his own padlock (up to three can be fitted), the fitter/electrician can protect himself against the possibility of any other person switching On the machine without authority.

Maintenance switches are merely additional, enclosed main switches with a padlocking facility. Such switches can be found on Pages 07/012–015 or07/024–025 of this catalogue.

FeaturesSafety switches are housed in insulated enclosures as standard and bear the inscription “Safety switch” on a bright orange label. Labels in other languages are available.Switches to be used for Emergency-Stop switching have a special red handle and a yellow locking collar in accordance with STOP category 0 toIEC/EN 60204.If the switch is not admissible for use as an Emergency-Stop switch, both parts are grey for P7 switch-disconnectors (Type suffix “-GR”) or black for T and P switches (Type suffix “-SW”).The cover and handle are interlocked when a padlock is in place.

SelectionSwitches must be selected according to the following criteria:1) The motor switching capacity, where the switch is

fitted in such a way that the operator may use it for operational On and Off switching.

2) The motor rating applies for 3 poles as standard. Where the motor rating is divided between 6 poles, such as for a motor with star-delta starting, the 1.73 fold rating can be controlled with a 6-pole switch.

3) The uninterrupted current, where the switch has a load-shedding contact (LA). The load-shedding contact is an auxiliary contact, which is closed in the On position and opens early when switching Off, so that a contactor in the circuit takes over the switching capacity, and the maintenance/safety switch operates at zero load. When switching On, the LA closes later than or at the same time as the main contacts. With T and P switches, this is achieved by the auxiliary make contact, with P7... switches, it is achieved by series connection of the early-make auxiliary contact (VHI) and a standard auxiliary contact (NHI).

4) The uninterrupted current, provided that the switch is safely prevented from switching under load.

5) This can be achieved for example by padlocking the handle (which may need to be changed accordingly) in the On position.This is not admissible for switches with a red/yellow handle.

Old Type/New TypeOld Type New TypeP3-63/I-SI(-SW)(+HI..) P3-63/I4-SI(-SW)(+HI..)P3-63/I-SI(-SW)+N-P3 P3-63/I4-SI(-SW)+N-P3P3-63/I-SI(-SW)+N+HI11

P3-63/I4-SI(-SW)+N+HI11

T5B-3-8342/I-SI(-SW) T5B-3-8342/I4-SI(-SW)T5B-4-.../I-SI(-SW) T5B-4-.../I4-SI(-SW)P3-63/I-SI(-SW)(+HI..) P3-63/I4-SI(-SW)(+HI..)P3-63/I-SI(-SW)+N-P3 P3-63/I4-SI(-SW)+N-P3T5-.../CI19/SIH T5-.../I5-SIT5-3-8342/CI19/SIH T5-3-8342/I5-SIT5-.../CI19/SIH T5-.../I5-SI

Technical datafor P switch-disconnectors a Page 07/092Technical datafor T5(B) switch-disconnectors

a Page 07/090Dimensions for P

a Page 07/104Dimensions for T5(B)

a Page 07/101P7 Safety Switches63 A – 250 A

a Page 10/016

Safety switch with load shedding and indication

Indication Load sheddingOn Off

K1M

L2

NL3

L1

F1

K1M2

1

4

3

6

5

F2

1 3 5

2 4 6

M3

7 9 11

8 10 12

Q1

U V W

A2K1M

A1

A2H1 H2

F0 FAZ-B4HI

95

96

21

22

F2

O

13

14

I13

14

Page 82: 07/000 T Rotary Switches, P Switch-Disconnectors · Moeller HPL0211-2001/2002 T Rotary Switches, P Switch-Disconnectors Overview of Functions Rotary Switches Switch-Disconnectors

Moeller HPL0211-2001/2002

T Rotary Switches, TM Mini Rotary SwitchesOrdering of Non-Standard Contact Sequences

Rota

ry S

witc

hes

Swit

ch-D

isco

nnec

tors

07/110

Design notes for non-standard contact sequences

Key to type references

T . . . . . . . . . . - . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . - . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ./ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .+ . . . . . . . . . . . . . . . . . .

� � � � �

Switch size Number of contact units(2 contacts per contact unit)

Contact sequence numberWith manufacturing country identifier.For initial order enclose completed form (see next Page).Contact sequence number is issued by factory.For subsequent orders, Type suffix is sufficient.

Mounting form• Mounting form /E• Centre mounting /EZ (for T0, T3)• Surface mounting /I...1)

• Service distribution board mounting /IVS (for T0)

• Rear mounting /Z• Flush mounting main switches .../EA/

SVB2)

• Surface mounting main switches /I.../SVB

• Rear mounting main switches/V/SVB2)

• Mounting forms for TM: /E, /EZ or /IVS

Accessories

a Page 07/056 – 071State in full with every order!For TM.../EZonly +EZ/S... is possible

a Page 07/083

Max.units

Max.contacts

T0 11 22T3 11 22T5B 10 20T5 10 20TM 8 16

Contact sequenceThe Form FO 2 (see next Page) makes it easy to determine the contact sequence. Master copy

a Page 07/112

Switching angles30, 45, 60, 90°Preferred angle: 60°For On/Off switches: 90°For main switches: 90° as FS 908 Page

a 07/054Interruption of contact between 2 switch positions (On-Off-On) not admissible on T0;or on T3 and TM at switching angles of 30°, 45°; or on T5(T5B) at a switching angle of 30°

Terminal markingsTM switches have consecutive terminal markings, beginning with 1.

Spring-returnThe switching movement is limited by a stop. The switch returns under spring pressure to the last indexed position. Where a switch has spring-return from both directions, a maximum of three positions can be traversed.The return angle is <

m switching angle. A maximum of 6 contacts can be returned at the same time.

Fleeting contactsDuration of contact depends primarily on the speed of actuation. If a contactor is to be actuated by means of fleeting contact, the switching angle of the rotary switch must not be less than 60°, or the switching pulse may be too short. Fleeting contacts always act in both directions.

Complete rotationPossible only with a total switching angle of 360°. Unrestricted rotation in either direction. The number of switch positions multiplied by the switching angle must equal 360°. TM with 12 positions every 30° is possible only with complete rotation, not with stop.

Number of contact unitsNumber of contacts = Round up to nearest whole

2

Each contact chamber = contact unit has 1 or 2 contacts, each operated by a cam.On T5(B) one cam operates both contacts. Consequently:Where the total switching angle is less than 180°, the contacts can be operated independently of one another. At switching angles of 180° and above, two contacts per chamber are possible only if their switching sequences are the same, but offset by 180° (e.g. T5B-4-8235 step switch).

Standard featuresAs for rotary switches with standard contact sequences

a Page 07/006, 072 Notes PageTechnical data 07/090Dimensions 07/096Available mounting formsT0 07/084T3 07/085T5B 07/086T5 07/087TM 07/088

NotesThe sequence of the contacts may be changed if technical reasons so dictate.For non-standard switches it is preferable to arrange the links so that terminals whose numbers differ by 4 are linked with one another, e.g. terminals 1-5-9; 2-6-10; 3-7-11- or 4-8-12-. Such links can be removed (also applies for standard switches), whereas links 1-3, 2-4, 5-7, 6-8 cannot abe removed because they are situated within the switch.

Links between an even number and an odd number (e.g. 2-3) cannot be provided ex-factory, and must be supplied by the user.

1) T0-.../I1 up to 4 contact units T3-.../I2 up to 5 contact units

2) T0 up to 8 contacts = 4 contact units, T3 up to 12 contacts = 6 contact units

Page 83: 07/000 T Rotary Switches, P Switch-Disconnectors · Moeller HPL0211-2001/2002 T Rotary Switches, P Switch-Disconnectors Overview of Functions Rotary Switches Switch-Disconnectors

Rota

ry S

wit

ches

Swit

ch-D

isco

nnec

tors

07/111Moeller HPL0211-2001/2002

T Rotary Switches, TM Mini Rotary SwitchesOrdering of Non-Standard Contact Sequences

Erstbestellung für Nockenschalter T KombinationenInitial order for a T rotary switch combinationPremière commande de combinaisons de Commutateur T à cames

Auftrags-Nr.:Order number:N° de commande :

Position:Item:Poste :

Büro:Office:Bureau :

Bearbeiter:Name:Employé :

Kunde:Customer:Client:

Kundenspez.-Nr.:Customer number:N° client :

Datum:Date:Date :

Hinweis:Note:Note :

Die Anzahl der möglichen Kontakte sowie die Kombinationsmög-lichkeiten mit den Baufor-men entnehmen Sie bitte dem Hauptkatalog.

The number of possible contacts as well as possible combinations with mounting forms are shown in the Main Catalogue.

Reportez-vous au Catalogue Général pour connaître le nombre maximal de contacts et les possibilités de combinai-son selon les modèles.

Stückzahl:Quantity:Quantité :

Schaltwinkel:Switching angle:Angle de rotation :

Type:Type:Réfèrence :

Anzahl Kontakte:No. of contacts:Nombre de contacts :

Bauform:Mounting form:Modèle :

q 30

q TM

q 1

q 12

q✗ E

q✗ 45

q✗ T0

q 2

q 13

q EA/SVB

q EA/SVB-SWDM/Stück:DM/each:Prix unitaire :

q 60

q T3

q 3

q 14

q EZ

q EZ/OFS

q 90

q T5B

q 4

q 15

q I...

q T5

q 5

q 16

q I.../SVB

q I.../SVB-SW

q 6

q 17

q IVS

q 7

q 18

q V/SVB

q V/SVB-SW

q 8

q 19

q X

q XZ

q✗ 9

q 20

q Z

q 10

q 21

q✗ + S-T0

q 11

q 22

q +___________________

Frontschild Nr.Front Plate No.Plastron N°

FS _______________

Baueinheiten/Contact units/Galettes1 2 3 4 5 6 7 8 9 10 11

Rundschaltung

k Complete rotationRotation totaleautom. Rückzug

k✗ Spring-returnRetour autom.

BeschriftungMarking/Repérage

GradDegrees/Degrés

12

34

56

78

910

1112

1314

1516

1718

1920

2122

2324

2526

2728

2930

3132

3334

3536

3738

3940

4142

4344

270 1 ✗ ✗ ✗ ✗ ✗ ✗ ✗300315 2 ✗ ✗ ✗ ✗330 ✗

0 3 ✗ ✗ ✗3045 4 ✗60

Cont

act c

lose

d on

ly in

po

sitio

n 1

Switc

hing

with

inte

rrup

tion

of c

onta

ctSw

itchi

ng w

ithou

t int

erru

p-tio

nCo

ntac

t clo

sed

in

posit

ions

1 +

3Co

ntac

t clo

sed

inpo

sitio

ns 1

to 3

Flee

ting

cont

act

(onl

y w

ith 6

0° o

r 90°

)La

te-b

reak

con

tact

Early

-mak

e co

ntac

t

Cont

act w

ith a

utom

atic

sprin

g-re

turn

90120135150 Key withdrawability with ..S-T0 or SVA-T3:180 Pos. 1: Key withdrawable � With SVA-T3, it is possible to switch

between Pos. 1 and 2 even after the key has been withdrawn.210 Pos. 2: Key withdrawable

225 Pos. 3: Key withdrawable240 Pos. 4: Key not withdrawable:

Schlüssel abziehbarKey withdrawableRetrait de la clé

x

Typ für Nachbestellungen (vom Werk auszufüllen)Type for re-ordering (to be filled in by Factory)Référence pour commandes ultérieures (à compléter par l’usine) T___________________________________

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17 19

18

21

20

23

22

25

24

27

26

29

28

31

30

33

32

35

34

37

36

39

38

41

40

43

42 44 3300

30300

270

240 225

210180

150

135 120

90

60315 45

Es is

t mög

lich,

das

s si

ch a

us te

chni

sche

n G

ründ

en d

ie R

eihe

nfol

ge d

er K

onta

kte

ände

rt.

The

sequ

ence

of c

onta

cts

may

be

chan

ged

for t

echn

ical

reas

ons.

L’or

dre

des

cont

acts

peu

t êtr

e m

odifi

é po

ur d

es ra

ison

s te

chni

ques

.

Max. characters per switching angle on FS plateDegrees TM-E TM-EZ TM-IVS T0(3) T5(B)0.180 5 5 6 13 1330, 210, 330 8 7 4 8 845, 135, 225, 315 6 5 4 6 760, 120, 240, 300 5 5 3 5 790, 270 5 4 1 4 7150 4 4 4 8 8

Page 84: 07/000 T Rotary Switches, P Switch-Disconnectors · Moeller HPL0211-2001/2002 T Rotary Switches, P Switch-Disconnectors Overview of Functions Rotary Switches Switch-Disconnectors

Moeller HPL0211-2001/2002

T Rotary Switches, TM Mini Rotary SwitchesOrdering of Non-Standard Contact Sequences

Rota

ry S

witc

hes

Swit

ch-D

isco

nnec

tors

07/112

Erstbestellung für Nockenschalter T KombinationenInitial order for a T rotary switch combinationPremière commande de combinaisons de Commutateur T à cames

Auftrags-Nr.:Order number:N° de commande :

Position:Item:Poste :

Büro:Office:Bureau :

Bearbeiter:Name:Employé :

Kunde:Customer:Client:

Kundenspez.-Nr.:Customer number:N° client :

Datum:Date:Date :

Hinweis:Note:Note :

Die Anzahl der möglichen Kontakte sowie die Kombinationsmög-lichkeiten mit den Baufor-men entnehmen Sie bitte dem Hauptkatalog.

The number of possible contacts as well as possible combinations with mounting forms are shown in the Main Catalogue.

Reportez-vous au Catalogue Général pour connaître le nombre maximal de contacts et les possibilités de combinai-son selon les modèles.

Stückzahl:Quantity:Quantité :

Schaltwinkel:Switching angle:Angle de rotation :

Type:Type:Réfèrence :

Anzahl Kontakte:No. of contacts:Nombre de contacts :

Bauform:Mounting form:Modèle :

q 30

q TM

q 1

q 12

q E

q 45

q T0

q 2

q 13

q EA/SVB

q EA/SVB-SWDM/Stück:DM/each:Prix unitaire :

q 60

q T3

q 3

q 14

q EZ

q EZ/OFS

q 90

q T5B

q 4

q 15

q I...

q T5

q 5

q 16

q I.../SVB

q I.../SVB-SW

q 6

q 17

q IVS

q 7

q 18

q V/SVB

q V/SVB-SW

q 8

q 19

q X

q XZ

q 9

q 20

q Z

q 10

q 21

q +____________________

q 11

q 22

q +____________________

Frontschild Nr.Front Plate No.Plastron N°

FS _______________

Baueinheiten/Contact units/Galettes1 2 3 4 5 6 7 8 9 10 11

Rundschaltung

k Complete rotationRotation totaleautom. Rückzug

k Spring-returnRetour autom.

BeschriftungMarking/Repérage

GradDegrees/Degrés

12

34

56

78

910

1112

1314

1516

1718

1920

2122

2324

2526

2728

2930

3132

3334

3536

3738

3940

4142

4344

270300315330

030456090

120135150180210225240

Schlüssel abziehbarKey withdrawableRetrait de la clé

x

Typ für Nachbestellungen (vom Werk auszufüllen)Type for re-ordering (to be filled in by Factory)Référence pour commandes ultérieures (à compléter par l’usine) T__________________________

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17 19

18

21

20

23

22

25

24

27

26

29

28

31

30

33

32

35

34

37

36

39

38

41

40

43

42 44 330

030

300

270

240 225

210180

150

135 120

90

60315 45

Es is

t mög

lich,

das

s si

ch a

us te

chni

sche

n G

ründ

en d

ie R

eihe

nfol

ge d

er K

onta

kte

ände

rt. T

he s

eque

nce

of c

onta

cts

may

be

chan

ged

for t

echn

ical

reas

ons.

L’o

rdre

des

con

tact

s pe

ut ê

tre

mod

ifié

pour

des

rais

ons

tech

niqu

es.

Max. characters per switching angle on FS plateDegrees TM-E TM-EZ TM-IVS T0(3) T5(B)0.180 5 5 6 13 1330, 210, 330 8 7 4 8 845, 135, 225, 315 6 5 4 6 760, 120, 240, 300 5 5 3 5 790, 270 5 4 1 4 7150 4 4 4 8 8

Page 85: 07/000 T Rotary Switches, P Switch-Disconnectors · Moeller HPL0211-2001/2002 T Rotary Switches, P Switch-Disconnectors Overview of Functions Rotary Switches Switch-Disconnectors

Rota

ry S

wit

ches

Swit

ch-D

isco

nnec

tors

07/113Moeller HPL0211-2001/2002

T Rotary Switches, TM Mini Rotary SwitchesOrdering of Non-Standard Front Plates

Erstbestellung von SonderfrontschildernInitial ordering of non-standard front platesPremière commande de plastrons spéciaux

Auftrags-Nr.:Order number:N° de commande :

Position:Item:Poste :

Büro:Office:Bureau :

Bearbeiter:Name:Employé :

Kunde:Customer:Client:

Kundenspez.-Nr.:Customer number:N° client :

Stückzahl:Quantity:Quantité :

DM/Stück:DM/each:Prix unitaire :

Datum:Date:Date :

Non-standard front platesMarking:Front plate with black lettering

Insert textNote the maximum number of characters allowed outside the marked areas!

Type

q FS-SOND-T0 (T3, P1)Height of letters

� 2 characters � 2 characters

4 mm3 mm

q FS-SOND-P3 (T5B, T5)Height of letters

� 2 characters� 2 characters

8 mm5 mm

q

qFS-SOND-TM-EFS-SOND-TM-EZHeight of letters

� 2 characters approx.� 2 characters

3.5 mm3 mm

For P1 and P3 complete only the 270° and 0° positions

Max. number of characters possibleItemDegrees TM-E TM-EZ T0/P1 T5/P3 Dimensions0, 180 5 5 13 13 Type Size of front plate30, 210, 330 8 7 8 845, 135, 225, 315 6 5 6 7 TM-.../E 29

x 29 mm (for frame sizes 30

x 30)60, 120, 240, 300 5 5 5 7 TM-.../EZ(-...) 29

x 29 mm (for frame sizes 30

x 30)90, 270 5 4 4 7 T0, T3, P1 45

x 45 mm (for frame sizes 48

x 48)150 4 4 8 8 P3, T5, T5B 84

x 84 mm (for frame sizes 88

x 88)

Typ für Nachbestellungen (vom Werk auszufüllen)Type for re-ordering (to be filled in by Factory)Référence pour commandes ultérieures (à compléter par l´usine) FS.....................................................................................