02 dx200 platform

25
1 © Nokia Siemens Networks DX200 Platform.ppt / ET / 08-2007 Core Network Planning Workshop DX200 Platform

Upload: varawl

Post on 15-Oct-2014

597 views

Category:

Documents


20 download

TRANSCRIPT

Page 1: 02 DX200 Platform

1 © Nokia Siemens Networks DX200 Platform.ppt / ET / 08-2007

Core Network Planning WorkshopDX200 Platform

Page 2: 02 DX200 Platform

2 © Nokia Siemens Networks DX200 Platform.ppt / ET / 08-2007For internal use

Contents

Nokia MSCi, TMSCi, HLRi and SRRi (DX 200 platform)

• HW overview (cabinets, cartridges, functional units, PIU, MB etc)

• Interfaces

• Capacities and roadmap

Nokia MSCi

Nokia Transit MSCi

Nokia Compact MSCi

Nokia HLR

Page 3: 02 DX200 Platform

3 © Nokia Siemens Networks DX200 Platform.ppt / ET / 08-2007For internal use

Cartridge Construction Products - i-series

DX 200 MSCi

DX 200 Transit MSCi

DX 200 Compact MSCi

DX 200 HLRi

Page 4: 02 DX200 Platform

4 © Nokia Siemens Networks DX200 Platform.ppt / ET / 08-2007For internal use

Network Structure

NMS

SMSC

NETWORK SUBSYSTEMNETWORK SUBSYSTEM

MSCi

SMSC

VMS

Compact MSCiPBX

VMS

Transit MSCi

HLRi

ININ

BSS BSS

PBXPBX

PSTN/ISDN

PSTN/ISDN

Page 5: 02 DX200 Platform

5 © Nokia Siemens Networks DX200 Platform.ppt / ET / 08-2007For internal use

Cabinets

Height: 2 m, width: 90 cm, depth: 60 cm, according to ETSI standard

Internal cabling is always the same

Strappings done with pre-wired connectors

All delivered cabinets are pre-wired and equipped with all necessary cartridges and cables

Shorter installation time on site

Considerably fewer parts to be mounted

Page 6: 02 DX200 Platform

6 © Nokia Siemens Networks DX200 Platform.ppt / ET / 08-2007For internal use

Cabinet Types

MOMC - Main Operation and Maintenance Cabinet for MSCi

VLRC - Visitor Location Register Cabinet for MSCi

ETC - Exchange Terminal Cabinet for MSCi

GSWC - Group Switch Cabinet for MSCi

IWC - InterWorking Cabinet for MSCi

GSC - General Signalling Cabinet for Transit MSCi

MMAC - Compact MSCi Cabinet A

MMBC - Compact MSCi Cabinet B

HLRC - Home Location Register Cabinet

HLGC - Home Location Group Switch Cabinet

Page 7: 02 DX200 Platform

7 © Nokia Siemens Networks DX200 Platform.ppt / ET / 08-2007For internal use

Cabinet Parts

POWER SUPPLYCONNECTOR GROUP

FILTER

FUSE UNIT(PDFU)

DOOR RIGHT

RAIL FORSHELVES

CARTRIDGESHELF

COVER FOR WHEEL BOXADJUSTABLE FEET WHEEL

HORIZONTALGROUNDINGBAR

DOOR LEFT

CARTRIDGE

SIDE COVERPLATE - SCPOR EMC GASKETFRAME

VERTICALGROUNDING

BAR

COVER FORPOWER SUPPLY

CABLESUPPORT

Page 8: 02 DX200 Platform

8 © Nokia Siemens Networks DX200 Platform.ppt / ET / 08-2007For internal use

Cartridges

M4 x 10

Page 9: 02 DX200 Platform

9 © Nokia Siemens Networks DX200 Platform.ppt / ET / 08-2007For internal use

DX 200 MSCi Capacity (M13)

• Extendable from 100,000 subscribers (7 cabinets + 4 cabling cabinets) to 1,000,000 subscribers (15 cabinets + 8 cabling cabinets)

• BHCA capacity from 100.000 to 1,000,000

• 1,500,000 SMS/BH

• 688 PCMs with ECU

• 2048 GSW

• 1,000,000 subscribers• 200,000 Tel. subs• 1,000,000 BHCA• 1,500,000 BHSM• 16,700 Erlangs• 1392 ext. PCMs• 416 C7 links

• 1,000,000 subscribers• 200,000 Tel. subs• 1,000,000 BHCA• 1,500,000 BHSM• 16,700 Erlangs• 1392 ext. PCMs• 416 C7 links

Page 10: 02 DX200 Platform

10 © Nokia Siemens Networks DX200 Platform.ppt / ET / 08-2007For internal use

DX 200 MSCi

OMU

TGFP

CDSU GSW

BSS

NSS

X.25 or LAN to OMC andSMS

PSTN

VLRUCMCMUCCMU STU CHU

ET

ECET

CLS

PABXECET

ET

VDU andLPT

VDU andLPT

PAUBSUMFSU BDCUM

LANLAN

CASUCCSU

MB

LAN

Page 11: 02 DX200 Platform

11 © Nokia Siemens Networks DX200 Platform.ppt / ET / 08-2007For internal use

MSCi - Functional unit configurations

maxCCSUCASU 14 (incl. spares)PAUBSU 15 + 1 VLRU pairs 8ET 704ET&ECU 688BDCU 3CHU pairs 3CDSU 42MFSU 5 + 1

Page 12: 02 DX200 Platform

12 © Nokia Siemens Networks DX200 Platform.ppt / ET / 08-2007For internal use

MSCi Cabinet Layout (max. configuration)- Row 1

SDSTU

SDSTU

STU1

PDFU PDFU

BSU0

BSU1

CLBU

CLBU

xSU1

xSU0

MFSU2

BDCU1

xSU2

BSU2

BSU3

VLRU0-1

VLRU1-0

VLRU0-0

STU0

VLRU1-1

SDCHU

SDCHU

CHU0-1

PDFU PDFU

BSU4

BSU5

xSU4

xSU3

MFSU3

BDCU2

xSU5

BSU6

BSU7

VLRU2-1

VLRU3-0

VLRU2-0

CHU0-0

VLRU3-1

SDCHU

SDCHU

CHU1-1

PDFU PDFU

BSU8

BSU9

CLBU

CLBU

xSU8

xSU7

MFSU4

GSU6

xSU9

BSU10

BSU11

VLRU4-1

VLRU5-0

VLRU4-0

CHU1-0

VLRU5-1

SDCHU

SDCHU

CHU2-1

PDFU PDFU

BSU12

BSU13

xSU12

xSU11

MFSU5

GSU10

xSU13

BSU14

BSU15

VLRU6-1

VLRU7-0

VLRU6-0

CHU2-0

VLRU7-1

0

1

2

3

4

5

6

7

8

9

10

CLBU

CLBU

CLBU

CLBU

OMU0

OMU1

PDFU PDFU

CCMU1

M0

M1

CCMU0 C

LSU

CM0

SDOMU

CM1

SDOMU

CMU0

CMU1

MFSU1

BDCU0

MFSU0

MOMC VLRC VLRC VLRC VLRC

NOTE: xSU = CCSU/CASU/PAU as needed

Page 13: 02 DX200 Platform

13 © Nokia Siemens Networks DX200 Platform.ppt / ET / 08-2007For internal use

MSCi Cabinet Layout (max. configuration) - Row 2

PDFU PDFU

GSW0-0

GSW0-1

GSW0-2

GSW0-3

PDFU PDFU

GSW1-0

GSW1-1

GSW1-2

GSW1-3

0

1

2

3

4

5

6

7

8

9

10

PDFU PDFU

ECET

ECET ECET

ECET ECETEC

EC EC

CLBU

0

1

2

3

4

5

6

7

8

9

10

PDFU PDFU

CLBU

0

1

2

3

4

5

6

7

8

9

10CDSU

PDFU PDFU

CDSUCDSU

CLBU

CDSU CDSUCDSU

CDSU CDSUCDSU

CDSU CDSUCDSU

CDSUCDSU ECET

ECET ECET

ECET ECETEC

EC EC

0

1

2

3

4

5

6

7

8

9

10

GSWC GSWC ETC IWC ETC

Page 14: 02 DX200 Platform

14 © Nokia Siemens Networks DX200 Platform.ppt / ET / 08-2007For internal use

MSCi Cabinet Layout (max. configuration) - Row 3

CDSU

PDFU PDFU

CDSUCDSU

CLBU

CDSU CDSUCDSU

CDSU CDSUCDSU

CDSU CDSUCDSU

CDSUCDSU

0

1

2

3

4

5

6

7

8

9

10CDSU

PDFU PDFU

CDSUCDSU

CLBU

CDSU CDSUCDSU

CDSU CDSUCDSU

CDSU CDSUCDSU

CDSUCDSU

0

1

2

3

4

5

6

7

8

9

10

0

1

2

3

4

5

6

7

8

9

10

PDFU PDFU

CLBU

ECET

ECET ECET

ECET ECETEC

EC EC

PDFU PDFU

CLBU

ECET

ECET ECET

ECET ECETEC

EC EC

PDFU PDFU

CLBU

ECET

ECET ECET

ECET ECETEC

EC EC

ETCETC IWC ETC IWC ETC

Page 15: 02 DX200 Platform

15 © Nokia Siemens Networks DX200 Platform.ppt / ET / 08-2007For internal use

DX 200 Transit MSCi (M13) Capacity

• 1.400.000 BHCA• 20.000 Erlangs • 1024 C7 links• 1648 ext. PCMs• 784 PCMs with ECU

• 1.400.000 BHCA• 20.000 Erlangs • 1024 C7 links• 1648 ext. PCMs• 784 PCMs with ECU

• Extendable from 600,000 BHCA to 1,400,000 BHCA

• 2048 GSW

Page 16: 02 DX200 Platform

16 © Nokia Siemens Networks DX200 Platform.ppt / ET / 08-2007For internal use

DX 200 Transit MSCi

OMU

TGFP

GSW

MSC

NSS

X.25 or LAN to OMC andSMS

PSTN

CMCMUCCMU STU CHU

ET

ECET

CLS

PABXECET

ET

VDU andLPT

VDU andLPT

CASUMFSU BDCU

MB

M

LAN

PAUCCSU

LAN

Page 17: 02 DX200 Platform

17 © Nokia Siemens Networks DX200 Platform.ppt / ET / 08-2007For internal use

Transit MSCi - Functional unit configurations

maxCCSUCASU 33 (incl. spares)PAUET 864ET&ECU 784BDCU 5CHU pairs 3MFSU 4 + 1

Page 18: 02 DX200 Platform

18 © Nokia Siemens Networks DX200 Platform.ppt / ET / 08-2007For internal use

Transit MSCi Cabinet Layout (max. configuration)row 1

NOTE: xSU = CCSU/CASU/PAU as needed

OMU0

OMU1

PDFU PDFU

CCMU1

M0

M1

CCMU0 C

LSU

CM0

SDOMU

CM1

SDOMU

CMU0

CMU1

MFSU1

BDCU0

MFSU0

0

1

2

3

4

5

6

7

8

9

10

SDSTU

SDSTU

STU1

PDFU PDFU

CLBU

CLBU

xSU7

xSU6

MFSU2

BDCU1

xSU8

STU0

xSU0

xSU1

xSU2

xSU4

xSU3

xSU5

SDCHU

SDCHU

CHU0-1

PDFU PDFU

CLBU

CLBUxSU16

xSU15

MFSU3

BDCU2

xSU17

CHU0-0

xSU13

xSU12

xSU14

xSU10

xSU9

xSU11

SDCHU

SDCHU

CHU1-1

PDFU PDFU

CLBU

CLBU

xSU25

xSU24

MFSU4

BDCU3

xSU26

CHU1-0

xSU22

xSU21

xSU23

xSU21

xSU18

xSU20

SDCHU

SDCHU

CHU2-1

PDFU PDFU

CLBU

CLBUBDCU

4

CHU2-0

xSU31

xSU30

xSU32

xSU28

xSU27

xSU29

MOMC GSC GSC GSC GSC

Page 19: 02 DX200 Platform

19 © Nokia Siemens Networks DX200 Platform.ppt / ET / 08-2007For internal use

Transit MSCi Cabinet Layout (max. configuration)row 2

PDFU PDFU

GSW

GSW

GSW

GSW

PDFU PDFU

GSW

GSW

GSW

GSW

0

1

2

3

4

5

6

7

8

9

10

0

1

2

3

4

5

6

7

8

9

10

0

1

2

3

4

5

6

7

8

9

10

0

1

2

3

4

5

6

7

8

9

10

PDFU PDFU

CLBU

ECET

ECET ECET

ECET ECETEC

EC EC

PDFU PDFU

CLBU

ECET

ECET ECET

ECETECETEC

EC EC

GSWC GSWC ETC ETC

Page 20: 02 DX200 Platform

20 © Nokia Siemens Networks DX200 Platform.ppt / ET / 08-2007For internal use

Transit MSCi Cabinet Layout (max. configuration)row 3

ETCETCETC

0

1

2

3

4

5

6

7

8

9

10

0

1

2

3

4

5

6

7

8

9

10

PDFU PDFU

CLBU

ECET

ECET ECET

ECET ECETEC

EC EC

PDFU PDFU

CLBU

ECET

ECET ECET

ECET ECETEC

EC EC

0

1

2

3

4

5

6

7

8

9

10

PDFU PDFU

CLBU

ECET

ECET ECET

ECET ECETEC

EC EC

0

1

2

3

4

5

6

7

8

9

10

PDFU PDFU

CLBU

ECET

ECET ECET

ECET ECETEC

EC EC

ETC

Page 21: 02 DX200 Platform

21 © Nokia Siemens Networks DX200 Platform.ppt / ET / 08-2007For internal use

DX 200 HLRi (M13)

AUC EIR

3,750,000 subscribers 1,250,000 Telemetric Subs1,250,000 Telemetric Subs3,750,000 subscribers 1,250,000 Telemetric Subs1,250,000 Telemetric Subs

• AuC capacity: 7.500.000 subscribers

• EIR capacity: – 10 million entries on black list– 4 million entries on grey list (1...1,000 IMEIs/entry)– 200,000 entries on white list (1...1,000,000 IMEIs/entry)

• 512 C7 links

• 512 GSW

Page 22: 02 DX200 Platform

22 © Nokia Siemens Networks DX200 Platform.ppt / ET / 08-2007For internal use

DX 200 HLRi

OMU

GSW

X.25 or LAN to OMC andSMS

MSC

STU

ET

CLS

HLRET

VDU andLPT

VDU andLPT

CMMCCSU BDCU

ACU DBDUHLRUEMU

EIRU

MB

LAN

Page 23: 02 DX200 Platform

23 © Nokia Siemens Networks DX200 Platform.ppt / ET / 08-2007For internal use

HLRi - Functional unit configurations

max

CCSU 32 + 1EIRU 7ACU pairs 5ET 96BDCU 2HLRU pairs 10

Page 24: 02 DX200 Platform

24 © Nokia Siemens Networks DX200 Platform.ppt / ET / 08-2007For internal use

HLRi (3,750,000 subs) Cabinet Layout

0

1

2

3

4

5

6

7

8

9

10

PDFU PDFUCLBU

ET EIRU

0CCSU4

CCSU6

CCSU7

CCSU8

CCSU5

CLBU

PDFU PDFU

CLBU

ET EIRU

2EIRU1

CCSU10

CCSU11

CCSU12

CCSU9

CLBU

DBDU0-0

SDDBDU

DBDU0-1

ACU0-0

SDACU

ACU0-1

PDFU PDFU

BDCU0

BDCU1

CLSU

SDOMU

SDOMU

GSW1-0

GSW1-1

GSW0-0

GSW0-1

CMM0

CMM1

OMU0

OMU1

CCSU1

CCSU2

CCSU3

CCSU0

SDSTU

STU1

STU0

SDSTU

SDEMU

EMU1

EMU0

SDEMU

SDHLRU

HLRU0-1

HLRU0-0

SDHLRU

SDHLRU

HLRU1-1

HLRU1-0

SDHLRU

PDFU PDFU

CLBU

ET EIRU

3CCSU13

CCSU15

CCSU16

CCSU17

CCSU14

CLBU

ACU1-0

SDACU

ACU1-1

SDHLRU

HLRU2-1

HLRU2-0

SDHLRU

SDHLRU

HLRU3-1

HLRU3-0

SDHLRU

PDFU PDFU

CLBU

ET EIRU

4CCSU18

CCSU20

CCSU21

CCSU22

CCSU19

CLBU

ACU2-0

SDACU

ACU2-1

SDHLRU

HLRU4-1

HLRU4-0

SDHLRU

SDHLRU

HLRU5-1

HLRU5-0

SDHLRU

PDFU PDFU

CLBU

ET EIRU

5CCSU23

CCSU25

CCSU25

CCSU27

CCSU24

CLBU

ACU3-0

SDACU

ACU3-1

SDHLRU

HLRU6-1

HLRU6-0

SDHLRU

SDHLRU

HLRU7-1

HLRU7-0

SDHLRU

PDFU PDFU

CLBU

ET EIRU

6CCSU28

CCSU30

CCSU31

CCSU32

CCSU29

CLBU

ACU4-0

SDACU

ACU4-1

SDHLRU

HLRU8-1

HLRU8-0

SDHLRU

SDHLRU

HLRU9-1

HLRU9-0

SDHLRU

HLRC HLRC HLRC HLRCHLRCHLRCHLGC

Page 25: 02 DX200 Platform

41 © Nokia Siemens Networks DX200 Platform.ppt / ET / 08-2007